Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

1

QP CODE: 8553 /2/A Reg.no:

SRIRAM ENGINEERING COLLEGE


B.E/B.TECH. OBJECTIVE TYPE EXAMINATION - UNIT 2
III Year/ V Semester
DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING
EC8553 - DISCRETE-TIME SIGNAL PROCESSING
(Regulations 2017)
TIME: 30 min Answer ALL questions Maximum: 50 Marks
(Tick the Correct Answer)
Part-A (25 x 2=50 Marks)

1) When the frequency band is selected we can specify the sampling rate and the characteristics of the
pre filter, which is also called as filter?
a)Analog filter b)Anti aliasing filter c)Both a& b d)None of the mentioned

2) What are the main characteristics of Anti aliasing filter?


a) Ensures that bandwidth of signal to be sampled is limited to frequency range.
b) To limit the additive noise spectrum and other interference, which corrupts the signal.
c) Both a& b d)None of the mentioned

3) In IIR Filter design by the Bilinear Transformation, the Bilinear Transformation is a mapping from
a)Z-plane to S-plane ; b)S-plane to Z-plane; c)S-plane to J-plane; d)J-plane to Z-plane

4) In the Bilinear Transformation mapping, which of the following are correct?


a) All points in the LHP of s are mapped inside the unit circle in the z-plane
b) All points in the RHP of s are mapped outside the unit circle in the z-plane
c)Both a & b d)None of the mentioned

5) The Chebyshev filters have


1) Flat pass band; 2) Flat stop band; 3) Equiripple pass band; 4) Tapering stop band
a. 1 and 2 are correct; b. 2 and 4 are correct; c. 2 and 3 are correct; d. All the four are correct

6) Butterworth filters have 1) Flat stop band; 2) Flat pass band; 3) Tapering pass band; 4) Tapering stop band
a. 1 and 2 are correct; b. 2 and 4 are correct; c. 2 and 3 are correct ; d. All the four are correct

7) The frequency warping is referred as


1) lower frequencies in analog domain expanded in digital domain
2) lower frequencies in digital domain expanded in analog domain
3) non linear mapping 4) compression of higher frequencies
a. 1, 3 and 4 are correct; b. 2 and 4 are correct; c. 2 and 3 are correct; d. All the four are correct
8) The poles of a Chebyshev filter lie on a
a. Ellipse b.Circle c.Square d.Triangle
9) The impulse invariant method is obtained by
a. Sampling the impulse response of an equivalent analog filter
b. Taking backward difference for the derivative
c. Mapping from s-domain to z-domain
d. Approximation of derivatives
10) The filter that may not be realized by approximation of derivatives techniques are
1) Band pass filters; 2) High pass filters; 3) Low pass filters; 4) Band reject filters
a. 1, 2 and 3 are correct; b. 2 and 4 are correct; c. 2 and 3 are correct; d. All the four are correct
11) IIR filter design by approximation of derivatives has the limitations
1) Used only for transforming analog high pass filters; 2) Used for band pass filters having smaller resonant frequencies
3) Used only for transforming analog low pass filters; 4) Used for band pass filters having high resonant frequencies
a. 1, 2 and 3 are correct; b. 1 and 2 are correct; c. 2 and 3 are correct; d. All the four are correct
12) For a system function H(s) to be stable
a) The zeros lie in left half of the s plane; b) The zeros lie in right half of the s plane
2

c) The poles lie in left half of the s plane; d) The poles lie in right half of the s plane
13)The IIR filter designing involves
a. Designing of analog filter in analog domain and transforming into digital domain
b. Designing of digital filter in analog domain and transforming into digital domain
c. Designing of analog filter in digital domain and transforming into analog domain
d. Designing of digital filter in digital domain and transforming into analog domain
14)The poles of a Butterworth filter lie on a
a. Ellipse b.Circle c.Square d.Triangle
15) The transformation technique in which there is one to one mapping from s-domain to z-domain is
a. Approximation of derivatives; b. Impulse invariance method
c. Bilinear transformation method d. Backward difference for the derivative
16) Which of the following is one of the drawback of Impulse Invariance method?
a.One-one mapping; b.Many-one mapping; c)One-many mapping; d)Many-many mapping
17)The advantages of Bilinear Transformation are
a)No aliasing; b)Conformal mapping; c)Both a and b; d)None of the above
18)IIR filters are also known as
a)Non-Recursive filters; b) Recursive filters; c)Linear phase filters; d)FIR filters
19) The present output y(n) of an IIR filter is a function of
a)only past and present inputs; b)past outputs , past and present inputs; c)only on past ouputs; d)None of above
20)Prewarping is used to
a)compensate the effect of non-linear compression at HF; b) compensate effect of non-linear compression at LF ; c)introduce
non-linear compression at HF; d)None of the above.
21)For the same filter specifications , the number of poles in Butterworth filter is --------- when compared to Chebyshev filter.
a) More b)Less c)Equal d)None of the above
22)A normalized LPF can be transformed to a HPF by substituting
a)S =S/ΩC b)S =ΩC /S c) S =S +ΩC d) S =S* ΩC
23)Direct form- II realization is called canonic form because it
a) uses maximum number of delay elements b) uses maximum number of adders
c)minimizes the number of memory locations d)None of the above
24)Quantization errors can be minimized if a LTI system is realized in
a) Direct form- II b) Direct form- I c)Cascade form d)Parallel form
25) Type-I Chebyshev filters are ---------filters.
a)All-pole filters b)Pole-zero filters c)All-zero filter d) None of the above

Total marks obtained :

Signature of the faculty :


/ 50

You might also like