Kenics® WVM Static Mixers

for the Water Industry

The Kenics Water Vortex Mixer (WVM) The WVM mixers consist of a software. Additives injected at the wall
builds on the HEV static mixer to simple wall additive injection point, of the pipe are spread into a horseshoe
offer more flexibility for differing flow a pre-distribution tab immediately shape by the pre-distribution tab.
conditions and improved additive downstream of the injection point and
injection. Three different WVM designs banks of trapezoidal shaped mixing Use of the pre-distribution tab allows
are available. These allow the project elements. The number of banks of the simplest of injectors to be used –
design parameters of length and mixing elements varies depending on either a flanged nozzle or a threaded
pressure drop to achieve a certain CoV the mixture quality required for the boss to which the chemical injection
within a certain time to be optimized. process. The dimensions, angle of line can be connected. A proprietary
attack and spacing of the trapezoidal injection fittings with corporation cock
Length to mixing elements varies between the shut off device can also be fitted to the
Achieve WVM models A, B and C. The pre- wall mounted boss if required.
Pressure Mixture distribution tab and the injection point
Model
Loss Quality design are the same for all WVM The pre-distribution tab was shown to
(CoV) of 0.05
(5%)
models. improve quantifiable mixture quality
(CoV) by at least 10% over a wide
WVMA Highest Shortest WVM Pre-distribution Tab range of flow rates compared to the
WVMB Medium Medium The pre-distribution tab was visually use of a multihole sparger injector. The
modeled and optimized in Chemineer’s improvement in mixing at low Reynolds
WVMC Lowest Longest number (velocity 0.1 m/sec) conditions
laboratory before being modeled again
using CFM (Computation Fluid Mixing) was the greatest.
CoV = Coefficient of Variation, or ó/x
is the standard deviation of additive
concentrations in any samples divided
by the mean mixed concentration of the
additive, a commonly used and quantifiable Visual modeling of
measure of mixture quality. the dispersion of
red dye into water
using the WVM pre
distribution tab.

Reynolds number 10,000 Reynolds number 100,000


CFM model showing
distribution of additive from
wall injection point

Typical WVM arrangement

WVM Mixing Elements The Kenics WVM has the


The banks of WVM mixing elements following key features:
are arranged in line with each other • Simple wall injection point
but off centre with respect to the pre-
• Optimization of length vs. pressure
distribution tab. The horseshoe shaped
drop parameters to suit the
pre-distributed additive is then caught
application is now possible
by the tips of the first bank of WVM
elements and drawn into the axially • Improved performance at very low
oriented spinning vortices behind them. flow rates (0.1-0.3 m/sec)
Each element creates two vortices • Lower capex and opex
and each bank therefore creates
End view down WVM mixer showing • Test data validated by independent
eight. The successive banks maintain
position of injection boss and pre- organization
and intensify vortices throughout the
distribution tab relative to mixing
length of the mixer and for some length elements
downstream.

Chemineer, Inc. Chemineer China Chemineer, Inc. Chemineer


5870 Poe Avenue Room 2006, Modern Plaza 125 Flagship Drive International Sales
Dayton, Ohio 45414 369 Xianxia Road North Andover, MA 01845 Offices:
Telephone: (937) 454-3200 Shanghai, CHINA 200336 Telephone: (978) 687-0101 Brazil
Email: chemineer@nov.com Telephone: 86-21-61240001 Email: navinfo@nov.com Mexico
Email: chemineercn@nov.com Singapore
Chemineer, Ltd. www.kenics.com
7 Cranmer Road, West Meadows www.greercomixers.com
Derby DE21 6XT, England
Telephone: 44-1-332-546700
Email: chemineeruk@nov.com

1-800-643-0641 • www.chemineer.com
National Oilwell Varco has produced this brochure for general information only, and it is not intended for design purposes. Although every effort has been made to maintain the
accuracy and reliability of its contents, National Oilwell Varco in no way assumes responsibility or liability for any loss, damage or injury resulting from the use of information
and data herein. All applications for the material described are at the user’s risk and are the user’s responsibility. All brands listed are trademarks of National Oilwell Varco.

© 2013 by Chemineer, Inc. Printed in U.S.A. 1013