Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 82

Revit Model Checklist

Vacation Items Checklist


Model Name :
PRF_P2_Fxx_Pxx_CNS-CON

Checked by : Ric Chan


Item Check Cases Category Description Phase Criticality Correction Imposed
by by
1 Model Preparation Check Gridline with "Master Grid Check" Construction Immediate BE Suncon
2 Model Preparation Model File name comforms to Standard Construction Immediate QCIC ATSB
3 Model Preparation True North is set correctly, origin of the model shall be reference to an Construction Immediate QCIC ATSB
established geospatially coordinated insertion point for all disciplines
4 Model Preparation Scale and coordinated grid line , correct discipline is selected >> Construction Immediate QCIC ATSB
Structural / Architectural / Mechanical to be Coordination

5 Model Preparation Remove all non-required Views / Legends/ Schedules / Lines / Shapes Construction Immediate QCIC ATSB
6 Model Preparation All families comform to BOQ conventions (QC via DE Tools) MTO Immediate QCIC Suncon

7 Model Preparation Overlay ARC model into CNS model, MEP model as well if available Construction Moderate BE Suncon

8 Model Validation Model elements contain right information e.g: Area, Level - top and Construction Immediate QCIC Suncon
base constraints, description, values (QC via Schedule , Properties
check)
9 Model Validation Model element has the correct material assigned (QC via DE Tools / Construction Immediate QCIC ATSB
Schedules)
10 Model Validation Correct Revit Category/Families assignment eg: Staircase use Model Construction Immediate BE ATSB
In Place, type of column, wall , slab according to standard naming
conventions specified in BEP

11 Model Validation Model is correctly assembled through visual inspection; e.g. (1) Construction Immediate BE ATSB
upstand beam should be vertical above the slab (2) Scupper should not
be under mass concrete (3) Staircaore should have opening instead of a
full length wall

10.1 Model Validation 2D_Check Wall Thickness Construction Immediate BE ATSB

10.2 Model Validation 2D_Check Floor Thickness Construction Immediate BE ATSB

10.3 Model Validation 2D_Check Column Location Construction Immediate BE ATSB

10.4 Model Validation 2D_Check Beams Size Construction Immediate BE ATSB

10.5 Model Validation 2D_Check Section Construction Immediate BE ATSB

10.6 Model Validation 2D_Check Scupper Drain Location Construction Immediate BE ATSB

10.7 Model Validation 2D_Check Offset Construction Immediate BE ATSB

10.8 Model Validation 2D_Check Boundary Construction Immediate BE ATSB

10.9 Model Validation 3D_Visual Inspection for Wall Construction Immediate BE ATSB

10.10 Model Validation 3D_Visual Inspection for Column Construction Immediate BE ATSB

10.11 Model Validation 3D_Visual Inspection for Slab Construction Immediate BE ATSB

10.12 Model Validation 3D_Visual Inspection for Beams Construction Immediate BE ATSB

10.13 Model Validation 3D_Scupper Drain Construction Immediate BE ATSB

10.14 Model Validation 3D_Perform verticality check for i.e: Walls ,Columns linking Revit model Construction Immediate BE Suncon
for lower / upper level
12 Model Validation All opening shall be modeled in their respective element; e.g. ceilings Construction Immediate BE ATSB
should have opening for lights, diffusers and etc
13 Model Validation Check "Warnings" and resolve it accordingly Construction Immediate BE ATSB

14 Model Validation Object Duplication Construction Immediate BE Suncon


15 Model Validation Object Overlapping with Others (Collaborate_Interference Check) Construction Immediate BE Suncon
16 Model Validation Is there any DWG files loaded into the model, remove unnecessary files Construction Immediate BE ATSB

17 Model Validation Is there any RVT files loaded into the model, remove unnecessary files Construction Immediate BE ATSB

18 Model Validation Purge unused elements to reduce file size and it helps MTO process. MTO Immediate QCIC ATSB
Repeat process 3 times as materials are only removed after the parent
object has been removed. Save as in compact mode, to reduce file size.

Page 1 of 82
Item Check Cases Category Description Phase Criticality Correction Imposed
by by
19 Model Validation Completed QC model is being saved: PRF_PX_FXX_P/LXX_CNS- MTO Minor QCIC Suncon
CON_Ric_QC
20 Model Validation Every trade and sub-trade shall be represented with color codes Construction Immediate BE ATSB
assigned and stated in BEP
21 Model Validation LOD of all model element shall be developed in alignment with AIA E202- Construction Immediate BE ATSB
2008 BIM Protocol Exhibit document and Guide, Instructions and
Commentary to AIA Document G202-2013, Project Building Information
Modeling Protocol Form by AIA

22 Model Validation All model shall be developed using object-based element such as Construction Immediate BE ATSB
column, staircase, ramp along with their associated parametric function
23 Model Validation MEP model shall be developed using specific system for each trade Construction Immediate BE ATSB
(if applicable) e.g. Cold Water system, Return Air Duct System etc. If new
system type is created, it hsall be based on the most similar system
classification e.g. Fresh Air Duct system to be duplicated from Supply Air
Duct System

24 Model Validation Ungroup grouped items Construction Immediate QCIC ATSB

25 Parameters Object Parameter - Is the Object Code created ? MTO Immediate QCIC Suncon
26 Parameters Object Parameter - assign the object code to Revit Families (QC via MTO Immediate QCIC Suncon
DE Tools)

27 Parameters Object Parameter - Object code assigned correctly MTO Immediate QCIC Suncon
28 Parameters Clean Irrelevant parameters MTO Minor QCIC Suncon
29 Parameters Correct Zoning assignment (Colorised Method , DE Tools) Construction Immediate BE Suncon
30 Parameters Object has been tagged with membermark MTO Immediate BE Suncon
31 Parameters Poundage assignment MTO Immediate BE Suncon
32 Parameters Review Tag categories assignment eg: check QC/ RFI/ Issues tracking Construction Moderate BE Suncon

Page 2 of 82
QC Related Issues

Item 1 Model File name comforms to Standard

Item 2 True North is set correctly

Item 3 Scale and coordinated grid line , correct discipline is selected


Coordinated Grid.

Correct scale

Item 4 Remove all non-required Views / Legends/ Schedules / Lines / Shapes


Item 5 All families comform to BOQ naming conventions (QC via DE Tools)
Item 6 Overlay ARC / MEP Model for crosss checking

Item 7 Elements with Right Information

** F01P03 model consist of F03&F04 Levels as Base / Top Level reference


Item 8 Model element has the correct material assigned
Item 9 Correct Revit Category/Families assignment
Should be Column Stump for 950 x 950
Item 10 Correct Forms

Item 10.1 2D_Check Wall Thickness

Item 10.2 2D_Check Floor Thickness


Item 10.3 2D_Check Column Location

Revit Model - Missing columns


Item 10.4 2D_Check Beams Size

** Upstand beam is not reflected in model


Item 10.5 2D_Check Section

Revit Model- Section U-U reflected wrongly CAD_PRF-PKG1-TWK-ED

Item 10.6 2D_Check Scupper Drain Location

Scupper drain underneath of mass concrete


Item 10.7 2D_Check Offset

Item 10.8 2D_Check Boundary


Item 10.9 3D_Visual Inspection for Wall

Item 10.10 3D_Visual Inspection for Column

Item 10.11 3D_Visual Inspection for Slab

Item 10.12 3D_Visual Inspection for Beams

Item 10.13 3D_Scupper Drain

Revit Model - i) Missing Scupper Drain CAD_PRF-PKG1-TWK-ED


ii) Missing part of Scupper Drain
Item 10.14 3D_Verticality Check

Item 11 Opening check

Item 12 Warnings
Item 13 Duplication

* 2 beams in a same location


Item 14 Object Overlapping with Others - Interference

Item 15 DWG file


Item 16 RVT File

Item 17 Purge

Before Purge
Item 25 Object code assignment
Item 26 Correct object code assignment

Item 27 Clean irrelevant parameters


Item 28 Zoning Assignment

Item 29 Membermark Assignment

Item 30 Poundage Assignment


CAD_PRF-PKG1-TWK-EDP-CNS-CN-LT-P03-001C-R00 - Column Loc
CAD_PRF-PKG1-TWK-EDP-CNS-CN-LT-P03-001C-R00 - Correct Section
CAD_PRF-PKG1-TWK-EDP-CNS-CN-LT-P03-001C-R00 - Scupper Drain Location
T-P03-001C-R00 - Column Location
Project : Parcel F
Subject : True North

Block Angle
F01 357.764°
F02 357.764°
F03 357.764°
F04 357.764°
F05 14.469°
F06 357.764°
F07 357.764°
F08 19.188°
F09 19.188°
F10 9.340°
F11 357.764°
STEPS TO CREATE COMPARISON TEMPLATE
1 Excel - Copy and paste Value for Revit Family & Revit Type from BQ

2 Excel - Delete empty row


After selecting the data range, continue as follows:
1. Press [F5].
2. In the resulting Go To dialog box, click Special.
3. Click the Blanks option and click OK. Doing so selects the blank cells
(what you might think of as rows) in the selected range.
4. Delete the selected cells

3 Revit - Export family and type from DE Tools, select the following
parameter:
a) Revit FamilyType

b) Poundage

c) Zone

d) Membermark

e) Object Code

4 Excel (from DE) - Move the Worksheet to the Comparison Template

5 Excel (from DE) - Repeat the process for Worksheets exported from DE
tools in item 2

6 Excel (from DE) - Filter the required Family

7 Excel - Copy and paste to Excel Template

8 Excel - Filter the item with 0 in CHECK column

9 Adjust the Revit Family


PROJECT PARCEL F
BLOCK : F01
SUBJECT : Revit Type Comparison - BQ vs REVIT

REVIT Family Type has BQ FamilyType has been


been assigned correctly assigned to REVIT

NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 65 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 66 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 67 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 68 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 69 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 70 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 71 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 72 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 73 of 82
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks

Page 74 of 82
PROJECT PARCEL F
SUBJECT : STRUCTURAL ELEMENT AND REVIT FAMILY CATEGORY

ITEM Structural Elements

1 Columns, Circular Columns, Stumps, Stiffener

2 Shear Wall, Core Walls, Walls, Parapet Wall,


Planter Box

3 Beams, Lintels

4 Suspended Slabs, Prestressed slabs, Staircase


Landings, Ramp Slopping Slabs, Mass Concrete

5 Pile caps, Footings and Piles

6 Stair flights, Steps, Scupper Drain, Precast Drain

Kerbs
Plinths
AMILY CATEGORY

Revit Family Category Remarks

Structural Columns

Walls (Strucutral Wall Type)

Structural Framing

Floors (Structural Floor Type)

Structural Foundations

Generic Models (In-Place)


DETools Parameter

1 ElementID

2 Family and Type


3 Poundage
4 Zone
5 Object Code
6 Membermark
7 Area
8 Volume
9 ConVolume
10 Length
11 Perimeter
Project : Parcel F
Subject : Poundage

Item Description Object Avg Poundage


kg/m³

1 Pilecap PLC 250


2 Column COL 105
3 Corewall CWL 150
4 Beam BEM 160
5 Conventional Slab SLB 160
6 Ramp Wall RAM 150
7 Parapet Wall UPS 150
8 Planter Box Wall UPS 100
9 Water Tank Wall WTW 200
10 Staircase STR 120
11 Drop Panel DRP 160
12 Kerb UPS 30
Mass Concrete MCN
Retaining Wall RWL

For Prestressed Slab

LEVELS F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 F11
(kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3)
P3 0.000
P2 60.45 59.69 56.37 60.04 63.88 62.39 52.11 47.84 64.18
P1 62.37 57.21 60.59 62.15 64.36 61.90 65.24 64.00 61.71 51.32 64.18
L1 71.12 69.96 68.84 75.85 71.89 67.03 67.23 68.32 69.71 71.39 79.55
L2 62.01 63.38 58.86 62.89 74.12 66.52 57.36 44.63 44.63 44.63
L3 62.64 63.34 62.80 62.97 65.76 65.76 62.36 55.71 55.71 55.71
L4 61.05 58.55 62.79 61.71 64.27 65.36 51.79 56.10 56.10 56.10
L5 60.54 62.48 62.79 60.78 63.18 65.19 77.29 55.04 55.04 55.04
L6 59.46 61.09 64.71 57.26 64.11 65.03 52.81 52.81 52.81
L7 58.57 62.48 63.40 56.11 62.27 61.64 53.70 53.70 53.70
L8 62.21 63.51 63.92 52.50 65.56 64.18 55.39 55.39 55.39
L9 60.19 59.44 59.14 48.84 73.72 71.09 55.27 55.27 55.27
L10 61.22 71.80 73.99 50.07 55.14 55.14 55.14
L11 60.83 49.57 69.70 69.70 69.70
L12 60.60 47.44
L13 61.31 48.00
L14 (roof) 75.45 59.25