Professional Documents
Culture Documents
C-Dot Max-Ng: Je (Cdot) Ravi Patel/Jto (Cdot) M M Swarnkar Mehsana Ssa
C-Dot Max-Ng: Je (Cdot) Ravi Patel/Jto (Cdot) M M Swarnkar Mehsana Ssa
C-Dot Max-Ng: Je (Cdot) Ravi Patel/Jto (Cdot) M M Swarnkar Mehsana Ssa
2. NOW CONNECT THE THIN-CLIENT WITH ANY FREE ETHERNET PORT(RJ-45) AVAILABLE ON THE MLS-0 CARD AT THE
7TH SLOT OF THE CACU CHASSIS.
3. ASSIGN AN IP ADDRESS TO THE THIN-CLIENT/PC USING THE IP ADDRESS AVAILABLE AT THE SITE.
4. ON THE THIN CLIENT/PC FOR INSTALLATION,GO TO THE PATH WHERE CACU APPLICATION RELEASE DELIVERABLES
HAVE BEEN COPIED USING COMMAND:
#cd /FIELD_PACKAGE/CACU_SOURCE/PATCH4-Over-SLM1_1_1.5_1-install_cacu_cards_NGTJ-INSTALL.sh
# ./ PATCH4-Over-SLM1_1_1.5_1-install_cacu_cards_NGTJ-INSTALL.sh
7. WHEN THE SCRIPT/PATCH IS RUN FOR THE FIRST TIME ON A PARTICALAR THIN-CLIENT/PC, THE SCRIPT/PATCH WILL
INITIATE THE UNZIPPING OF THE RELEASE FILES LOCALLY TO ARRANGE THEM IN A STRUCTURE AS REQUIRED
DURING THE INSTALLATION ON THE CARDS.
ENTER IP FOR EMS (ELIMENT MANAGEMENT SYSTEM) MANAGER = 10.187.4.41 (CORE IP BHOPAL)
12. ENTER THE IP OF THE NTP (NETWORK TIME PROTOCOL) SERVER = 10.187.4.12
13. ENTER PERIODICITY FOR SYNCING WITH NTP SERVER(IN SECONDS) = 900
14. NOW THE USER IS DISPLAYED THE VALUES THAT HAVE BEEN ENTERED SO FAR AND IS ASKED WHETHER THESE
VALUES HAVE TO BE CHANGED.(IN CASE OF SOME DISCREPANCY). TO CHANGE ANY VALUE, ENTER THE NUMBER
CORRESPONDING TO IT.
16. NOW ENTER y FOR CONFIRMING THE IPS OF PHYSICAL CARD OF CACU CHASSIS.
SLM
19. IS THE SYSTEM IN DUPLEX (Y/y) OR SIMPLEX (PRESS ENTER) = y
21. AFTER ENTERING IP ADDRESS OF SLM CARDS, THE SSH PROMPT IS SHOWN, SOMETHING SIMILAR TO THE
FOLLOWING:
22. THIS WILL DISPLAY AN OUTPUT AS THE FOLLOWING AND ASK FOR THE PASSWORD FOR THE ROOT USER OF CACU
CARD (SLM/EBM/NGTJ) ON WHICH THE INSTALLATION OPTION HAS BEEN SELECTED :
Warning: Permanently added ‘SLM CARD IP' (RSA) to the list of known hosts.
root@ SLM CARD IP's password:(Default is root)
Now try logging into the machine, with "ssh 'root@ SLM CARD IP'", and check in:
.ssh/authorized_keys
to make sure we haven't added extra keys that you weren't expecting.
NOTE: This “warning “ is not actually an error or a warning and should be ignored.
23. DURING THE INSTALLATION OF THE SLM CARDS, SOME PRINTS WOULD BE SHOWN RELATED TO FILE TRANSFER AND
FILE CREATION. ONE INPUT WILL BE ASKED RELATED TO THE SECURE CONNECTION BETWEEN THE ACTIVE AND
STAND-BY SLM CARDS, WHICH WILL BE SOMETHING SIMILAR TO THE FOLLOWING:
******************************************************
* ssh key file not present on this system
* You will have to press enter thrice in a row
******************************************************
Here, the user will be have to press the Enter key thrice for the secure key creation.3
24. ONCE THE INSTALLATION IS FINISHED ON THE SLM CARDS (SIMPLEX OR DUPLEX), THE SCRIPT WILL SHOW THE
FOLLOWING OUTPUT
EBM
25. ONCE THE INSTALLATION IS COMPLETED ON THE SLM CARD , THE SCRIPT RETURNS TO THE MAIN MENU AS THE
FOLLOWS AND THE INSTALLATION FOR EBM CARD SHOULD BE SELECTED AFTER THIS
NOTE: EBM COPY-0 AND COPY-1 INSTALLATION IS SAME AS ABOVE SLM CARD INSTALLATON.
NGTJ
26. NOW THE USER WILL AGAIN PRESENTED THE MAIN MENU OF THE SCRIPT AND THE USER SHOULD SELECT THE
APPLICATION RELEASE INSTALLATION FOR OTHER CACU CARD, SAY NGTJ CARD.
28. NOW, WHEN THE USER ENTERS AN IP ADDRESS, HERE 10.187.1.5 IS AN EXAMPLE, THE SSH PROMPT IS SHOWN,
SOMETHING SIMILAR TO THE FOLLOWING:
29. THIS WILL DISPLAY AN OUTPUT AS THE FOLLOWING AND ASK FOR THE PASSWORD FOR THE ROOT USER OF CACU
CARD (SLM/EBM/NGTJ) ON WHICH THE INSTALLATION OPTION HAS BEEN SELECTED :
Warning: Permanently added NGTJ CARD-0 IP' (RSA) to the list of known hosts.
root@ NGTJ CARD-0 IP's password:(Default is root)
Now try logging into the machine, with "ssh 'root@ NGTJ CARD-0 IP'", and check in:
.ssh/authorized_keys
to make sure we haven't added extra keys that you weren't expecting.
NOTE: This “warning “ is not actually an error or a warning and should be ignored.
30. NOW THE OPERATOR IS PRESENTED WITH SOME INFORMATION REGARDING THE NGTJ CARD OS RELEASE VERSION
AND THE FPGA VERSION. WHEN ASKED TO CONTINUE WITH THE INSTALLATION, THE OPERATOR SHOULD ENTER ‘Y’.
NGTJ release on NGTJ NGTJ CARD-0 IP is 1.52 and Control FPGA version is 21 on (NGTJ)
Time switch FPGA version is 21 on (NGTJ)
NGTJ @ NGTJ CARD-0 IP has 72% free space left
31. ONCE THE INITIAL I2C DRIVER RELATED INSTALLATION IS DONE ON THE NGTJ CARD, A WELCOME MESSAGE IS
DISPLAYED TO THE OPERATOR, HAVING SOME INFORMATION ENCLOSED IN A TEXT BOX. IT STARTS WITH A TEXT
BOX THAT LOOKS SIMILAR TO:
@@@@@@@@@@ @@@@@
@@@@@@@@@@ @@@@@
@@@@@@@@@@ @@@@@
@@@@@
@@@@@ @@@@@
@@@@@ @@@@@
@@@@@@@@@@@@@@@@@
@@@@@@@@@@@@@@@@@
@@@@@@@@@@@@@@@@@
C-DOT
At the end of the text it asks whether the operator wants to continue with the installation and to modify the ‘default input’ file. The operator
should continue (y) with the installation and should not modify the ‘default input’ file. The screen output is:
32. UPON CONTINUING WITH THE INSTALLATION OF THE CACU NGTJ CARD, SOME OTHER INPUTS WILL ALSO BE TAKEN
FROM THE USER. THESE INCLUDE THE C5 SERVER IP ADDRESS, C4 SERVER IP ADDRESS, WHETHER TO ENABLE A
PARTICULAR GATEWAY ON THE NGJT CARD AND LIKEWISE. THE OUTPUT IS SHOWN AS FOLLOWS
33. ONCE THE ABOVE FIELDS ARE ENTERED, SOME CONFIGURATION ENTRIES WILL BE ASKED FROM THE OPERATOR,
SUCH AS THE IP ADDRESSES OF THE C5 AND C4 SERVERS, ENABLING PR/DR FEATURE CONFIGURATION, DOMAIN
NAME, IP ADDRESSES OF THE NAMESERVERS, DOMAIN NAME OF THE SBC ETC. (R MAY BE PRESSED IN A LATER
INSTALLATION WHEN THESE VALUES ARE KNOWN TO BE PRESENT ALREADY, BUT FOR THE FIRST TIME SITE
MIGRATION CONFIGURATION, THE VALUES SHOULD BE ENTERED ACCORDING TO THE SITE). THE OUTPUT SHOWN IS
AS FOLLOWS:
34. IN CASE THE OPERATOR OPTS TO NOT PROCEED WITH THE INSTALLATION, THE OPTIONS PRESENTED BY THE SCRIPT
ARE
36. ONCE THE INSTALLATION STEP REACHES THE SG INSTALLATION, IT ALSO ASKS FOR SOME INPUTS, RELATED TO THE
SG SERVER AND PR-GR CONFIGURATION.
THE OUTPUT IS SIMILAR TO THE FOLLOWING AND THE USER SHOULD ENTER THE VALUES ASKED:
39. When the installation of release is completed on the NGTJ card, the NGEMS agent installation on the NGTJ card, per gateway is asked, and
the user should enter ‘y’ according to the gateways installed on the CACU NGTJ card. An example output is:
In the above example, the NGTJ card Agent has been selected for installation and the user has selected Y.
Similarly for other Agents, such as PRI EMS GatewayAgent , V5 EMS Gateway Agent and SG EMS Gateway Agent, whichever is applicable, y
should be entered to installed otherwise, only Enter should be pressed to skip a particular gateway agent installation.
41. Once the installation is completed on the NGTJ Copy-0 card , the script returns to the main menu as the follows and the installation for EBM
card should be selected after this