measure 20 meters from the assigned point to the first set up of the tripod.
STEP 3: Then, set up the tripod.
STEP 4: Attach the device on the plate of
the tripod, then level the device by adjusting the leveling screws.
STEP 5: Check the calibration by turning
the device 180°.
STEP 6: Twist the device's focusing knob
until the image is clear.
STEP 7: After reading the level of BM1,
record the data and signal the rodman to move on the next point. STEP 8: Measure another 20 m from the tripod then rotate the device 180°.
STEP 9: Then, read the level of IFS1.
Record the data gathered.
STEP 10: Measure another 20 m and mark
it as the IFS2. Read the level of IFS2 and measure another 20 m for the IFS3. Read STEP 11: Then, move the tripod, 20 m the level of IFS3 and record the data. from IFS3.
STEP 12: Then check the device if it is
leveled properly. If not, level it first STEP 13: Repeat the process of the first before gathering data. set up, read the level of BS1, IFS4, IFS 5 and IFS 6. Then move to 3rd and last set up. Then read the level of BS2, IFS7, IFS8 and BM2.
STEP 14: After recording all the data,
pack all the instruments and make sure that they are all in good state.