Adjusted maximum allowable shut-in casing

pressure
Post Views: 1,641

You calculate the maximum initial shut-in casing pressure (MISICP) based on the original
mud weight before you start drilling ahead. Once you drill deeper, you may increase mud
weight. With new mud weight, you are not able to use the MASICP calculated by the
initial weight because higher mud weight will reduce the MASCIP. The formula below
demonstrates you how to adjust the MASICP with new mud weight.

Adjusted MASICP = Leak off pressure – [Shoe TVD x (MW2 – MW1)] x


0.052

Where;

Adjusted MASCIP = maximum allowable shut-in casing pressure in psi

Leak off pressure = pressure you get when you perform leak off test in psi

Shoe TVD = true vertical depth of casing shoe in ft

MW2 = current mud weight in pgg

MW1 = original mud weight in ppg

Let’s learn about it via this example.

Casing shoe depth is at 5000’MD/4500’TVD. Leak off test is performed with 9.5 ppg and
the leak off pressure is 1000 psi. The current operation is drilling ahead with 12.0 ppg.
Determine the adjusted MASCIP with current mud weight.

Adjusted MASICP = 1000 – [4500 x (12.0 – 9.5)] x 0.052

Adjusted MASICP = 415 psi


If you take a kick with 12.0 ppg mud in hole, you maximum allowable surface casing
pressure is only 415 psi.