Cylindrical Type

Cylindrical type proximity sensor


(A)
Counter
▣Features
lReverse power polarity protection(DC),
Surge protection function (B)
Timer
lOver current protection function
(M12, M18, M30 DC Type)
lLong life cycle and High reliability
(C)
lAble to check the status of operation by Temp.
controlle
Red LED indicator
lEconomical and simple operation
lWide range of applications for replacement of
(D)
Micro switch, Limit switch Power
controlle
lWater proof structure by IP 67(IEC specification)

Please read "Caution for your safety" in operation (E)


! manual before using. Panel
A001572 meter

▣Specifications (F)
Tacho/
Speed/
Pulse
lDC 2-wire type meter

PRT08 -1.5 DO PRT08-2DO PRT12-2DO PRT12-4DO PRT18-5DO PRT18-8DO PRT30-10DO PRT30-15DO


Model (G)
PRT08 -1.5 DC PRT08-2DC PRT12-2DC PRT12-4DC PRT18-5DC PRT18-8DC PRT30-10DC PRT30-15DC Display
unit
Detecting distance 1.5mm ±10% 2mm ±10% 2mm ±10% 4mm ±10% 5mm ±10% 8mm ±10% 10mm ±10% 15mm ±10 %
Hysteresis Max. 10% of detecting distance
Standard detecting 18×18× 25×25× 30×30× 45×45×
target 8×8×1mm(Iron) 12×12×1mm(Iron) 1mm(Iron) 1mm(Iron) 1mm(Iron) 1mm(Iron) (H)
Sensor
Setting distance controlle
0~1.05mm 0~1.4mm 0~1.4mm 0~2.8mm 0~3.5mm 0~5.6mm 0~7mm 0~10.5mm
Power supply 24VDC
(Operation voltage) (15-30VDC)
(I)
Leakage current Max. 0.9mA Proximit
sensor
Response frequency 800Hz 400Hz 350Hz 200Hz 250Hz 100Hz
Residual voltage Max. 7V
Affection by Temp. ±10% Max. for detecting distance at +20℃ within temperature range of -25 ~ +70℃ (J)
Photo
Control output 2~50mA electri c
sensor
Insulation resistance Min. 50MΩ(at 500VDC)
Dielectric strength 1500VAC 50/60Hz for 1minute
Vibration 1mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours (K)
Pressur
Shock 500m/s²(50G) in X, Y, Z direction for 3 times
sensor
Indicator Operation indicator(RED LED)
Ambient temperature -25 ~ +70℃(at non-freezing status)
Storage temperature -30 ~ +80℃(at non-freezing status) (L)
Rotary
Ambient humidity 35 ~ 95%RH encoder

Protection circuit Surge protection circuit, Overload & short circuit protection(except PRT08 series)
Protection IP67(IEC specification) (M)
5-Phase
Cable spec. ø4×2P, 2m ø5×2P, 2m stepping
motor &
Approval Driver &
Controlle
Weight Approx. 36g Approx. 36g Approx. 63g Approx. 63g Approx. 122g Approx. 122g Approx. 181g Approx. 181g

I-8
PR Series
lSpecifications(DC 3-wire type)
P R08- 1.5DN PR08-2DN PR18-5DN PR18-8DN PR 30 -10 DN P R 30- 15D N
PR12-2DN PR12-4DN
P R08- 1.5DP PR08-2DP PR18-5DP PR18-8DP PR 30 -10 DP P R 30- 15D P
PR12-2DP PR12-4DP
P R08- 1.5DN2 PR08-2DN2 PR18-5DN2 PR18-8DN2 PR 30 -10 DN 2 P R 30- 15D N 2
PR12-2DN2 PR12-4DN2
P R08- 1.5DP 2 PR08-2DP2 PR18-5DP2 PR18-8DP2 PR 30 -10 DP 2 P R 30- 15D P 2
Model PR12-2DP2 PR12-4DP2
P RL 08-1.5DN PRL08-2DN PRL18- 5DN PRL18-8DN PR L 30- 10D N P R L 30- 15D N
PRS12-2DN PRS12-4DN
P RL 08-1.5DP PRL08-2DP PRL18- 5DP PRL18-8DP PR L 30- 10D P P R L 30- 15D P
PRS12-2DP PRS12-4DP
P RL 08-1.5DN 2 PRL08-2DN2 PRL18- 5DN2 PRL18-8DN2 PR L 30- 10D N 2 P R L 30- 15D N2
PRS12-2DN2 PRS12-4DN2
P RL 08-1.5DP 2 PRL08-2DP2 PRL18- 5DP2 PRL18-8DP2 PR L 30- 10D P 2 P R L 30- 15D P 2
Detecting distance 1.5mm ± 10% 2mm ± 10% 2m m ± 10% 4mm ±10% 5m m ± 10% 8mm ± 10% 10m m ± 10% 15mm ±10%
Hysteresis Max. 10% of detecting distance
S tandard det ect ing 18× 18×1mm 25× 25× 1mm 30× 30× 1mm 45×45× 1mm
8× 8×1m m(Iron) 12× 12×1m m(Iron)
target (Iron) (Iron) (Iron) (Iron)
S etting dist ance 0~1.05mm 0~1.4mm 0~1.4mm 0~2.8mm 0~3.5m m 0~5.6mm 0~7mm 0~10.5mm
P ower supply 12-24VDC
(Operat ion volt age) (10-30VDC)
Current consumption Max. 10mA
Response frequency 800Hz 400Hz 350Hz 200Hz 250Hz 100Hz
Residual voltage Max. 2V Max. 1.5V
A ffect ion by Temp. ±10% Max. for detec ting distance at +20℃ within temperature range of -25 ~ +70℃
Control output 200m A
Insulation resistance Min. 50MΩ (at 500VD C)
Dielectr ic st rength 1500VAC 50/60Hz for 1minute
Vibration 1mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours
S hock 500m/s² (50G) in X, Y, Z direction for 3 times
Indicator O peration indic ator(RED LED)
A mbient temperature -25 ~ +70℃ (at non-freezing status)
S tor age t emperature -30 ~ +80℃ (at non-freezing status)
A mbient humidity 35 ~ 95%RH
P rot ect ion cir cuit Surge protection circuit, Overload & short circ uit protection(except PR08 and P RS 12 series)
P rot ect ion IP67(IEC specifica tion)
Cable s pec. ø 4×3P, 2m ø5× 3P, 2m
A pproval
PR:Approx. 70g PR:Approx. 70g PR:Approx. 119g PR:Approx. 118g PR:Approx. 184g PR:Approx. 181g
Weight Approx. 36g Approx. 36g PRS:Approx.68g PRS:Approx.68g PRS:Approx.150g PRS:Approx.150g
PRS:Approx.222g PRS:Approx.227g

lSpecifications(AC 2-wire type)


PR18-5AO PR18-8AO PR30- 10AO PR30-15AO
PR12-2AO PR12-4AO PR18-5AC PR18-8AC PR30- 10AC PR30-15AC
Model
PR12-2AC PR12-4AC PRL18-5AO PRL18-8AO PRL30-10AO PRL 30-15AO
PRL18-5AC PRL18-8AC PRL30-10AC PRL 30-15AC
Detecting distance 2mm ± 10% 4mm ± 10% 5mm ± 10% 8mm ±10% 10mm ±10% 15mm ± 10%
Hyster esis Max. 10% of detecting distance
St andard detecting 18×18×1mm 25×25×1mm 30×30×1mm 45×45×1mm
12×12×1mm(Iron)
target (Iron) (Iron) (Iron) (Iron)
Setting dist ance 0~1.4mm 0~2.8mm 0~3.5mm 0~5.6mm 0~7mm 0~10.5mm
Power supply 100-240VAC
(Operation voltage) (85-264VAC)
Curr ent consumption Max.2.5mA
Response frequency 20Hz
Residual voltage Max. 10V
Affection by Temp. ±10% Max. for detecting distance at +20℃ within tem perature range of -25 ~ +70℃
Control output 5~150mA 5~200mA
Insulation resistance Min. 50MΩ(at 500VDC)
Dielectric str ength 2500VAC 50/60Hz for 1minute
Vibration 1mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours
Shock 500m/s²(50G) in X, Y, Z direction for 3 times
Indicator Operation indicator(RED LED)
Ambient temperature -25 ~ +70℃(at non-freezing status)
St orage temperature -30 ~ +80℃(at non-freezing status)
Ambient humidity 35 ~ 95%RH
Pr otection circuit S urge protection circuit built-in
Pr otection IP 67(IEC s pecification)
Cable spec. ø4×2P, 2m ø5×2P, 2m
Approval
A 00 157 2

PR : Approx. 130g PR : Approx. 130g P R : Approx. 185g P R : Approx. 117g


Weight Approx. 66g Approx. 66g PRS : Approx150g PRS : Approx150g P RS : Approx224g P RS : Approx222g

I-9
Cylindrical Type
▣Dimensions Unit:mm
(A)
lPR(T)08-1.5D3 lPR(T)18-5D3 Counter
47 2,000
ø 15 30 2,000 ø29 33.5
13 24 Operation
4 29
indicator (B)
Timer

ø4
M8× 1 Operation ø5 (C)
indicator M18×1 Temp.
4
controlle
lPR(T)08-2D3 lPR(T)18-8D3
47 2,000
4 26 2,000 ø29
ø 15 33.5
4 Operation (D)
24 10 19 Power
indicator
13 controlle

ø4
M 8×1 Operation (E)
indicator ø5 Panel
M18×1 meter
4

lPRS12-2D3 lPR(T)30-10D3 (F)


58 Tacho/
35.5 2,000 Ø42 43 2,000 Speed/
ø21 Pulse
28.5 35 38 Operat ion meter
17 Operation indicator
24.5 indicator

(G)
Display
unit

M12×1 ø4
M30×1.5
5
(H)
lPRS12-4D3 lPR(T)30-15D3 Sensor
controlle
58 2,000
35.5 2,000 Ø42 43
ø 21 Operation
28.5 35 10 28 (I)
Operation indicator Proximit
17
7 17.5 indicator sensor

(J)
ø5 Photo
M12×1 ø4
electric
4 M30×1.5 sensor
5

lPR(T)12-2D3 (K)
42.5 2,000 Pressur
ø 21 sensor
35.5 Operation
17 indicator
31.5

(L)
Rotary
encoder
M 12× 1 ø4
4
(M)
lPR(T)12-4D3 5-Phase
stepping
42.5 2,000 mot or &
Dr iver &
ø 21 35.5 Controlle
Oper ation
17 7 24.5 indicator

M12× 1 ø4
4

I-10
PR Series
▣Dimensions Unit:mm

lPRL08-1.5D3 lPR12-2A3
59.5 2,000
2,000 Ø21
Ø15 40 52.5 Operation
17
13 4 48.5 indicator

Ø4 Ø4
M12×1
M8×1 4
Operation
indicator
lPRL08-2D3 lPR12-4A3
59.5 2,000
4 36 2,000 Ø21
Ø15 52.5 Operat ion
13 4 17 indicator
7 41.5

Ø4 Ø4
M12×1
M8×1 4
Operation
indicator

lPRL18-5D3 lPRL18-5A3 lPR18-5A3

80 2,000 53.3 2,000


Ø29
Ø29 66.5 Operation 39.8 Operation
24 62 indicator 24 35.3 indicator

Ø5 Ø5
M18×1 M18×1
4 4

lPRL18-8D3 lPRL18-8A3 lPR18-8A3


53.3 2,000
80 2,000
Ø29 39. 8
Ø29 66.5 Oper ation Oper ation
10 52 indicator 24 10 25.3
24 indicator

Ø5 Ø5
M18×1 M18×1
4 4

lPRL30-10D3 lPRL30-10A3 lPR30-10A3


80 2,000
58 2,000
Ø42 65 Ø42
43 Operation
35 60 Operation 35
indicator 38 indicator

Ø5 Ø5

M30×1.5 M30×1.5
5 5

lPRL30-15D3 lPRL30-15A3 lPR30-15A3


58 2,000
80 2,000
Ø42 Ø42
65 43 Operation
35 Operation
10 50 35 10 28 indicator
indicator

Ø5 Ø5

M30×1.5 M30×1.5
5 5

I-11
Cylindrical Type
▣Control output diagram ▣Connections
(A)
◎DC 2-wire type ◎DC 2-wire type Counter

Brown Brown
Load +V
NO NC Load +V
Detecting Pres ence
target Nothing
(B)
Blue Timer
0V
Operation
Load
Return

Indicator Brown (C)


ON +V Temp.
Blue (LED)
0V OFF controlle

Blue
Load 0V
◎DC 3-wire type ※Load can be connected to either wire. (D)
Power
controlle
NPN
NO NC
◎DC 3-wire type
Brown Detecting Presence
+V (E)
target Nothing Black Panel
Load
10K Load Blue meter
Operation
Black (Brown-Black) Brown
Return
9 10 11 12

2Ω O・C
(F)
Output voltage H +12 G ND IN1 OUT 1

Tacho/
(Black-Blue) L
+1 2 G ND IN2
O・C
OUT 2 Speed/
Blue 13 14 15 16 Pulse
0V Indicat or ON O UT2 meter
O UT1
(LE D) OFF PA 10 -U
OR AN D

(PRA18-5DN)
NO RM I NV
NORM IN V
IN 1 NO RM

M SA
IN 2 O O SB
O
D F
F N SC
(G)
E

Display
SD

PNP PO WER A
D
J
TIME O
F
F
O T1
N T2
unit
M AD E I N K O R EA

5 6 7 8

Brown NO NC
Detecting Presence
+V
target Nothing (PRA18-5DN) NC C OM NO

1 2 3 4
(H)
Load Operation Sensor
2Ω Black < PA 10-U > controlle
(Black-Blue) Return

10K Output voltage H


Load (Brown-Black) L
Black Brown Blue (I)
Blue Indicat or ON Proximit
0V 8 9 10 11 12 13 14
(LE D) OFF (PRA18-5DP) sensor
cp 1 cp 2 + 12V 0V

(J)
◎AC 2-wire type Photo
electri c
sensor
Br own NO NC ~ 100-
Load Detecting 240VAC
Presence 1 2 3 4 5 6 7
tar get Nothing
AC
<FX4 > (K)
~ Pressur
POWER Operation sensor
Load
Return
◎AC 2-wire type
Blue Brown
Load
Indicator ON (L)
(LED) OFF Rotary
100-
~ 240VAC
encoder

Blue
(M)
5-Phase
Brown stepping
motor &
Driver &
Controlle
100-
~ 240VAC
Blue
Load

※Load can be connected to one of wired.

I-12
PR Series
▣Proper usage
◎Load connections
Brown Brown
Load Load
+ +
~ POWER 24VDC ~ 100-240VAC
- -

Blue Blue

<DC 2-wire type & AC 2-wire type > <DC 2-wire type > <AC 2-wire type >

When using DC or AC 2-wire type proximity sensor, the load must be connected otherwise internal components
may be damaged. And the load can be connected to either wire.

◎In case of the load current is small


lAC 2-wire type
Load It may cause return failure of load by residual voltage.
If the load current is under 5mA, please make sure the
AC
~ POWER residual voltage is less than the return voltage of the load
Bleeder resistor(R)
by connecting a bleeder resistor in parallel with the load
as shown in the diagram.
110VAC : 20kΩ min. 3W, 220VAC : 39kΩ min. 10W

lDC 2-wire type


Load Please make the current on proximity sensor smaller than
+ the return current of load by connecting a bleeder resistor
Vs in parallel.
Bleeder resistor(R) - ※W value of Bleeder resistor should be bigger for proper
heat dissipation.
Vs *Vs : Power supply
R≤ (kΩ) P : Bleeder resistor, number of W
Io-Ioff
Io : Operating current of proximity sensor
Vs² (2.5mA but, PRT08, PST17 is 0.9mA)
P> (mW)
R Ioff : Return current of load

◎Mutual-interference & Influence by surrounding metals


lMutual-interference
When several proximity sensors are mounted close together, malfunction of sensor may be caused due to
mutual interference. Therefore, be sure to provide a minimum distance between the two sensors, as below
charts.

Parallel B
A

Face to Face

lInfluence by surrounding metals


When sensors are mounted on metallic panel, you must prevent the sensors from being affected by any
metallic object except target. Therefore, be sure to provide a minimum distance as below chart.

ød n


ℓ Unit:mm
PR(T)18-5D PR(T)18-8D PR(T)30-10D PR(T)30-15D
Model PR(T)12-2D PR(T)12-4D
PR08-1.5D PR08-2D PRL18-5D PRL18-8D PRL30-10D PRL30-15D
PRS12-2D PRS12-4D
PRT08-1.5D PRT08-2D PR18-5A PR18-8A PR30-10A PR30-15A
Item PR12-2A PR12-4A
PRL18-5A PRL18-8A PRL30-10A PRL30-15A
A 9 12 12 24 30 48 60 90
B 16 24 24 36 36 54 60 90
ℓ 0 8 0 11 0 14 0 15
ød 8 24 12 36 18 54 30 90
m 4.5 6 6 12 15 24 30 54
n 12 24 18 36 27 54 45 90

I-13