Professional Documents
Culture Documents
Design Calculations
Design Calculations
PE 15,000
Qdwf (m3/d) (PE X 0.225) 3375
p PE/1000 15
Peak flow coefficient 4.7 x p^(-0.11) 3.4892
Qpeak (m3/d) Qdwf x pfc 11776
BODin (kg/d) (Qdwf x 1000 x 250 mg/L)/1,000,000 kg 843.75
Ssin (kg/d) (Qdwf x 1000 x 300 mg/L)/1,000,000kg 1012.5
TKN 50
AERATION TANK
PE 15000
DWF (m3/d) 3375 0.039
Pflow (m3/d) 11776 0.14
Chemical Oxygen
500
Demand (COD)
Total Nitrogen (TN) 50
Ammoniacal Nitrogen
30
(AMN)
Operating Temperature 26
Operating Ph 7.2
HRT 19.712
6.3 MLSS
Assume
MLSS 3500
MLVSS, Xv Rule of thumb (75%) 2625
Solids in aeration tank V x MLSS 9702
Anoxic Volume
Anoxic Volume Required 225
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
Oc
mg/l 3.5
mg/l
kg
d
d
d (>20, as per MSIG)
m3
m3
Design Calculations
PE 10,000
Qdwf (m3/d) (PE X 0.225) 2250 (m3/d)
p PE/1000 10
Peak flow coefficient 4.7 x p^(-0.11) 3.4892
Qpeak (m3/d) Qdwf x pfc 7851
BODin (kg/d) (Qdwf x 1000 x 250 mg/L)/1,000,000 kg 562.5
Ssin (kg/d) (Qdwf x 1000 x 300 mg/L)/1,000,000kg 675
TKN 50
Nox 80% of TKN 40
Wastewater characteristics
Constituent Concentration (mg/L)
BOD5 250
SBOD 80
TSS 300
VSS 273
COD 500
Scod 150
VFA as SCOD 30
TKN 50
TKN with filtrate returned (+15%) 58
NH4-N 30
TP 10
PO4-P 4
SVI
Xs 6666 MLSS Concentration i
X 3500 MLSS Concentration i
BCOD/BOD ratio 1.6
Operating Temperature 26 C
Required Effluent
BOD5 10
SS 20
COD 60
AMN 0.5
TN 10
TP N/A
O&G 2
Step 1
Develop wastewater characteristics for process design
BCOD 1.6(BOD) 400 mg/L
BPCOD 1.6(BOD-SBOD) 272 mg/L
PCOD COD-SCOD 350
BPCOD/PCOD 0.78
nbVSS (1-(BPCOD/PCOD))*BOD 55.71
Itss TSS(initial)-VSS(initial) 27 mg/L
Step 3 Determine fill fraction per cycle (VF/VT) allowed and compare to selected design value 0.3
Mass balance based on solids in reactor
Mass of solids at full volume = Mass of settled solids
VtX=VsXs
Step 7
Determine amount of NH4-N oxidized (NOx)
Nitrogen balance NOx = TKN0 - Ne- 0.12 Px,bio/Q
Px,bio Items A + B + C (See formula in pg 729) 99849.01 g/d
99.84901 kg/d
NOx NOx = TKN0 - Ne- 0.12 Px,bio/Q 38.84944 g/m3
Step 8 Check degree of nitrification to determine NH4-N will be removed to level of 5 g/m3 in 2 hr aer
a) Determine amount of oxidizable N available
Vf(NOx) 10926.4 g/fill
Vs(Ne) Ne(V-Vf) 328.125 g
Total oxidizable N 24328.13 g
No Total oxidizable N/Vt 25.95 g/m3
0.093 m3/s
0.91 VSS/TSS
VSS/g Nox
A 1021075
B 1128214
C 40521.1
D 418603.4
E 546750
*1 1025316
m3.g/m3) *2 1128214
*3 39836.07
*4 15934.43
A 48217.44
B 2213.115
C 49418.46
Oxidizable 24000
A 1.933423
B 25.45
C 103.8373
A 450000
B 141785.6
C 189245.3
m3/h/diffuser
m3/min/diffuser
m3/min/diffuser
TSS/g BOD
VSS/g BOD
TSS/g BCOD
Parameter
Biochemical Oxygen Demand (BOD5)
Suspended Solids (SS)
Chemical Oxygen Demand (COD)
Total Nitrogen (TN)
Ammoniacal Nitrogen (NH4-N)
Total Phosphorus (TP)
Oil & Grease (O&G)
For SBR
Equipments Unit price (RM) Nos. Cost
Decanter
Type : Surface Skimming
Motor : 2.2 KW 2,000 2 4000
RAS/WAS Sludge Pump
Type : Submersible Pump
Motor : 7.5 Kw 40,000 16 640000
Air Blower
Type : Rotary Air Blower
Motor : 132 KW 70,000 3 210000
Air Diffuser
Type : Fine air bubble tube
diffusers
Submergence : 5m
Efficiency : 24% 1,000 296 296000
Total estimated cost 1150000
For EA
Equipments Unit price Nos. Cost
MLSS Pump
Type : Submersible Pump
Motor : 3.7 Kw 200,000 2 400000
Air Blower
Type : Rotary Air Blower
Motor : 15 KW 70,000 3 210000
Air Diffuser
Type : Fine air diffusers
Submergence : 5m
Efficiency : 24% 1,000 125 125000
Clarifier Scraper
Type : Half-Bridge Periphereal
Drive Scraper
Motor : 0.2 Kw 90,000 2 180000
RAS Pump
Type : Submersible pump
Motor : 5.5 KW 40,000 2 80000
WAS Pump
Type : Submersible pump
Motor : 0.4 KW 40,000 2 80000
Total estimated Cost 1075000
SBR
Structure Length(m) Width(m) Thickness
Base slab 22.7 18.9 0.3
Wall 1 & Wall 2 22.7 5.3 0.3
Wall 3 18.3 5.3 0.3
Wall 4 & Wall 5 8 5.3 0.3
Wall 6 12.3 5.3 0.3
Wall 7 20.9 5.3 0.3
Top slab 1 22.1 1 0.3
Top slab 2 16.9 1 0.3
Top slab 3 8 1 0.3
Top slab 4 20.9 1 0.3
Amount of
EA
Structure Length(m) Width(m) Thickness
Base slab 24.2 18.9 0.3
Wall 1 & Wall 2 24.2 5.3 0.3
Wall 3 & Wall 4 18.3 5.3 0.3
Wall 4 23.6 5.3 0.3
Wall 5 & Wall 6 6 5.3 0.3
Top slab 1 24.2 1 0.3
Top slab 2 24.2 2.9 0.3
Top slab 3 7 1 0.3
Clarifier tank
Mass of ste
Tremie 2
223
232
242
253
266
261
1 0 0 1 1
6
0 0 1 0 0
1
Type of Premises/Establishment Unit RecommendeActual unit Actual PE
Residential per hou 5 1350 6750
Commercial areas (Office, Shopping compleper 100 3 22500 675
Day schools per stu 0.2 1000 200
Fully residential educational institution per res 1 1500 1500
Hospital per bed 4 100 400
Petrol kiosk per toil 15 2 30
Bus terminal per bus 4 15 60
Mosque per per 0.2 300 60
Golf course per hol 20 9 180
Laundry per ma 10 10 100
Total PE 9955
Structure Nos. Length(m) Width(m) Surface Area(m2)
Selector Tank 2 1.2 9 21.6
SBR Tank 2 20.9 9 376.2
Total Surface Area 397.8
Clarifier
Sludge produced 188.6 kg/d
RAS pump capacity 1.94 m3/min
WAS pump capacity 0.02 m3/min
Peak flow Meets HRT
Trial No.of tank Width Depth Length (m)
(Qdwf) requirement?