Purlins All members of truss are made of NB50 GI Pipe

1.5 m

@ 0.75m Each
Span: 4.5 m

Figure - 1 : Truss Details


Columns @ 3 m C/C

15 m

Figure - 2 : Shed Plan


0.25 m

Girts NB50 GI Pipes

4m

Bracing NB50 GI Pipe

2m

Stiffners
(10 mm thickness 100H X 75B

Columns (NB100 Pipes) @ 3 m C/C


Base Plates (300X300 mm & 10 mm thickness)

Figure - 3 : Side Wall


GI Ridging

GI Sheet Roofing

0.25m

Girts NB50 GI Pipes

4m

Figure - 4 : Back Wall (Gable end)


300

1550

A A

10TOR @ 200 C/C (Bothways)

250 mm

100 THK. PCC (1:4:8)

10TOR @ 200 C/C (Bothways)

1500 mm

@ 4-12 TOR
300
@ 4-16 TOR

300 8 TOR STPS. @ 100 C/C

SECTION AT 'A-A'

Figure - 5 : Foundation and Pedestal details