Tampering Methods of Energy Meter

JUNE 8, 2011  18 COMMENTS (HTTPS://ELECTRICALNOTES.WORDPRESS.COM/2011/06/08/TAMPERING‑METHODS‑OF‑
ENERGY‑METER/#COMMENTS)

Tampering Method of Electrical Energy Method:

Following Description is only for awareness regarding Electrical Energy Theft. Do not use these techniques otherwise You may
be booked under Electrical energy theft act 135.
(h푘ps://electricalnotes.files.wordpress.com/2011/06/1_page_1.jpg)
(h푘ps://electricalnotes.files.wordpress.com/2011/06/1_page_2.jpg)
(h푘ps://electricalnotes.files.wordpress.com/2011/06/1_page_3.jpg)
(h푘ps://electricalnotes.files.wordpress.com/2011/06/1_page_4.jpg)

Advertisements (https://en.support.wordpress.com/about­these­
ads/)

FILED UNDER UNCATEGORIZED
About Jignesh.Parmar
Jignesh Parmar has completed M.Tech (Power System Control), B.E(Electrical) from Gujarat University. He has more than 13 years
experience in Power Transmission‑Power Distribution‑Electrical energy theft detection‑Electrical Maintenance‑Electrical
Projects(Planning‑Designing‑coordination‑Execution). He is Presently associate with one of the leading business group as a Deputy
Manager at Ahmedabad,India. He is Freelancer Programmer of Advance Excel and design useful Excel Sheets of Electrical
Engineering as per IS,NEC,IEC,IEEE codes. He is technical Author for ʺElectrical Mirrorʺ and ʺElectrical Indiaʺ Magazines. He is
Technical Blogger and Familiar with English, Hindi, Gujarati, French languages. He wants to Share his experience & knowledge and
help technical enthusiasts to find suitable solutions and updating themselves on various Engineering Topics.

18 Responses to Tampering Methods of Energy Meter

rvg says:
June 24, 2011 at 9:28 am
Pls provide a method to tamper electronic meter and prepaid meters. Both having reverse protection as well as earthing load
indication.

Reply
davinder kumar says:
July 13, 2011 at 5:54 am
I like the site very much. it is very helpful for any electrical engr. Pls tell me somthing about step potential ant touch potentia and
hw its value find out

Reply
Mohan Singh BISHT says:
November 2, 2011 at 4:56 pm
I like this site & very useful for electrical engineer. Thank you Mr.Jignesh.Parmar, Pl. tell me about;
1. Impulse & Short circuit testing of transformer. Are these test done on both winding (H.V. &L.V.), if not why only H.V.
winding.
2. Partial discharge on cables

Reply
Gufran Khan says:
January 17, 2012 at 8:03 am
fabulous site, I didnt studies this much in engineering life too

Reply
roger smith says:
June 20, 2012 at 11:27 am
how do i get a prepaid meter with tamper protection back online

Reply
ghanshyam says:
August 17, 2012 at 9:11 am
thanks

Reply
john says:
October 8, 2012 at 6:19 pm
i am amazed on how many tampering methods available. are all these working?

Reply
manu says:
February 27, 2013 at 6:27 am
Sir , There is no case of neutral disturbance like diode injection please explain how diode injection affect the meter reading

Reply
Robert says:
March 23, 2013 at 12:44 pm
I’d like to ask the group a question if I may?

Can a BURNT three phase home meter give a true consumption reading of electricity?

I am insisting that a Burnt meter needs to be tested and any readings taken from a Burnt meter would be false readings.
I am insisting that a Burnt meter needs to be tested and any readings taken from a Burnt meter would be false readings.

Without testing, the power company is saying that the meter readings are accurate.

What can I do?

Can anyone direct me to the literature or links that will prove my case?

Thank you

Robert

Reply
Brian says:
April 16, 2013 at 8:41 pm
hi there,

do u have methods to illustrate about electrical theft through digital meter having three phase?

Reply
paul says:
April 25, 2013 at 11:11 am
Nice article…thanks for the article. but i would have loved to have the effects of each tamper on the meter measurement and
accuracy and suggestion for manufacturer to put measures in place to checkmate them. thanks,

Reply
G Mani says:
November 5, 2013 at 7:21 am
Jignesh bhai what are you trying to do. We people are already corrupt – please do not add any more corruption. Showing the
methods of energy meter tampering do not add any value to any one’s engg. knowledge.

Reply
Kanagavalli.B says:
November 20, 2013 at 9:35 am
I have a doubt in current reversal due to reversal of phase and neutral terminals in digital meter can you explain me?

Reply
Sudesh Haldanker says:
September 8, 2014 at 11:10 am
Previously i used to cosumed 250 – 270 KWH units before installation of digital meter After installation of digital electic meter it
above 1000KWH unitsWhy is it so high.can you guide me

Reply
Bihari Lal says:
September 11, 2015 at 4:19 pm
It is a good way of study prevent electrical theft in our distribution in

Reply
Munish says:
November 25, 2015 at 4:49 am
Pleasssse… have some common sense. This article will do only more bad than good, if any. That one line disclaimer is just a
formality to save your own a$$ you know that!

Reply
sobhan says:
July 31, 2016 at 5:36 am
sir full load earth returned(tampered) method, is it done by without opening the seal

Reply
Arun says:
August 6, 2016 at 10:06 am
Hi Jignesh, thanks for sharing this wonderful information. I am a Dy. Superintendent of Police from U푘ar Pradesh presently
posted in Vigilance Unit to prevent Electricity theft.. I would appreciate if you help me personally by giving some more
information to us. Please get in touch with me..asap

Reply
Blog at WordPress.com.

You might also like