Setup

A:40.00 Sk:270 L:001


Beam Delay Start (Half Path) Range (Half Path) Acq Rate Type Averaging Factor
7.9 µs 0.00 mm 19.17 mm 15 PA 1
Scale Type Scale Factor Video Filter Pretrig. Rectification Filter
Compression 4 On 0.00 µs FW None (1.0 - 17.8 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width
40 (Low) 42.13 dB PE (Pulse-Echo) Shear 3240.0 m/s 65.00 ns
C -Scan Time A-Scan Time
Scan Offset Index Offset Probe Skew Digitizing Frequency
Resolution Resolution
0.00 mm 7.00 mm 270.0º 2.5 ns 100 MHz 40.0 ns
         
         

Gate Start Width Threshold Synchro. Peak Selection  


I Off Off Off Off Off  
A 2.05 mm 8.07 mm 15.00 % Pulse Max Peak  
B Off Off Off Off Off  

TCG Point Number Position (Half Path) Gain      


1 0.00 mm 0.0 dB      
2 9.14 mm 7.2 dB      
3 14.64 mm 5.1 dB      
4 19.73 mm 6.5 dB      

Calculator
Element Qty. Used First Element Last Element Resolution Wave Type Material Velocity
16 1 16 1.0 Shear 3240.0 m/s
Start Angle Stop Angle Angle Resolution Focus Depth Law Configuration Beam Skew
40.00º 75.00º 1.00º 20.00 mm Sectorial 0.00º

Part

Material Geometry Thickness Diameter    


STEEL, MILD Tube OD Circumferential 4.06 mm 50.80 mm    

Scan Area

Scan Start Scan Length Scan Resolution


0.00 mm 205.00 mm 1.00 mm
Synchro. Scan Speed        
Time 15.00 mm/s        

Axis Encoder Encoder Type Encoder Resolution Polarity  


Scan Off Off Off Off  
 

Table
Indication Scan Index DA^ PA^ SA^ U(m-r) I(m -r) I•U(m-r) S(m-r)
Ref. Group Channel A% (%)
# (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
- 1 58.00 -7.00 PA 1 59.00º 60.7 1.42 2.99 13.01 0.41 0.59 0.71 2.87

Indication
Ref. Scan Index Group Channel A% DA^ PA^ SA^ U(m-r) I(m -r) I•U(m-r) S(m-r)
#
- 1 58.00 mm -7.00 mm PA 1 59.00º 60.7 % 1.42 mm 2.99 mm 13.01 mm 0.41 mm 0.59 mm 0.71 mm 2.87 mm
Comments          
-

file:///C|/Users/PAUT-TOFD/Desktop/DATA/FWWP/BOTTOM/ACC/FWWP%20BOTTOM%20JT.2.htm[7/22/2019 9:19:35 AM]