Download as pdf
Download as pdf
You are on page 1of 4
(! ne Concrete l Precast Solutions HUME RC SQUARE PILE Features Quality Assured Production Hume RC Piles are manufactured under controlled conditions to ensure product quality and reliability. Hume AC Piles carry the SIRIM Certification under Quality System MS ISO 9001 : 2008, Wide Selection Of Pile Sizes and Classes Hume RC Piles are manufactured in sizes ranging from 150mm x 150mm to 400mm x 400mm. To suit different soil and design conditions, Hume RC Piles are available in two classes for each and every pile size, i.e. Standard and Customised. High Load Bearing Capaci With the use of high strength concrete in Grade 45 or Grade 60, Hume RC Piles are engineered to withstand higher loads during driving and in service. This facilitates the economical design of foundations to suit varying soil conditions. Production Hume RC Piles are manufactured in rigid and dimensionally accurate moulds to facilitate the accurate fixing of steel reinforcement cages and joint plates. With proprietary concrete mix design, high strength concrete is produced at our state-of-the-art concrete batching plant to ensure consistency and homogeneity in concrete mix. Hume RC Piles are capable of achieving the required strength for driving within 7-14 days, Specifications Hume RC Piles are designed to BS 8004 ; 1986 — British Standard Code of Practice for Foundation. (if requested, Hume can supply RC piles designed to other available Standards such as MS 1314 2004 and JKR Standard Specification.) Constituent Materials : (British Standards are quoted below. Other equivalent Standards, where applicable are acceptable) Cement BS 12: 1996 Ordinary Portland Cement Aggregates BS 882 ; 1992 Sand / 20mm Aggregates High Tensile Bar BS 4449 : 1997 Longitudinal Reinforcement Bars Cold Drawn Wire BS 4461 : 1978 Lateral Reinforcement Mild Steel Plate BS EN 10025 : 2004 End Plate (Grade $275) Admixture BS 5075-3: 1985 Superplasticizer Working Loads of Piles Maximum axial working loads on Hume RC Square Piles are calculated to BS 8004 : 1986 and Ci 116: 1969, Maximum Axial Working load = !% A + tae Ase 3.65 Where fou characteristic cube strength of concrete at 28 days 45 N/mm? or 60 N/mm? net area of concrete 175 Nim? for high yield reinforcement cross sectional area of longitudinal steel Dimensions & Details tae _--LeTia Hox i soa son { ont _ AAAI Y PA PTE | [ENS aT rTOH PY [NS ATAITCH 2 LINKS At PITGH Ps iD [MIS ATPTCH LS ATEMCHPY| | _asar 7 a Z peeve eee c : LENGTH “4 SECTIONAL VEW (EXTENSION FLED ry man penFoncement o] \f Tl tarexa nenroncevent 7 | some NOMINAL COVER 7 poo Types Of Pile Shoes es Five types of pile shoes are available to suit various driving and soil conditions, + Standard Pile Shoes + Pile Shoes For Special Application Type 2: Pisin Shoe Type: Fabricated Pointed Shoe «Type 1:Castlvon Shoe Type 4: Pointed Shoe ‘Type 6: Rock Shoe or Pine eee ~__ Pile Dimensions and Details ore Dimensions Main = Lateral Reinforcement ‘ieee Sie a |» | © | Reinforcement | wire |p, | x | pz | vy | ro Thickness (mm) (mom) | (mm) | (mm) | no. tm) | tm) | immi | imm)_| (mm) | tmm (mm) 150x150 | 153 | 147 | 150 | # 40 | 32_| 450 | 92.75 | 450 | 75 6 176x175 | 178 | 172 | 176 | 4 45 | 36 | 625 | 9605 | 625 | 0s 6 200x200 | 204 | 196 | 200 | 4 45_| 35 | 600 | 35100 | 600 | 100 sr 75x73 | 29 | 2a | zs |e | 10 50 | 40 | 705 | aoa5 | 70s | 115 8 250x260 | 254 | 246 | 250) 4 | 16 60 | 40 | 750 | a110 | 760 | 110 | 9000 8 276x275 | 270 | 2 | 2768 | 4 | 16 | 00 | 50 | 25 | sores | eas | 105 SEG 300x300 | 306 | 205 | 300 | 8 | 12 60 | 50 | 900 | 80-145 | 900 | 145 9 320x020 | 25 | 915 | 320 | 4 20 60 | 45 | 960 | 45-140 | 960_| 140 ® 350x360 | 955 | 045 | 350 | 4 | 20 6.0 | 48 | 1050 | 45-130 | 1050 | 130. 12 aaixsai_| 386 | 376 | sei] 4) 72 60 | 40 | 1145 | 40170 | 1145 | 120 2 “400 x 400 405 | 395 | 400 | 8 16 6.0 40 1200 | 40-115 | 1200 | 115 12 7 For maximum pile length only oo aa a mR ‘Pile Dimensions and Detatls Nominal + peinit2ia Pe Joint Plate Size a b © Rakeorcnmnent, x P2. ~ P3 ‘Thickness (mm) Dia. (mm) [tenem) [tent | tenemd | tenem) | tem) | tom) 160x150 | 153 ° “480 | 3276 | 460 | 75 | 4200 45. 175%. 178 @ 525_| 3565 | 525 | 65 | 3900 6 200x200 | 204 10 [600 | 35-100 | 600 | 100 | 3600 6 [26295 [229 2 [705 | 40.115 | 705 | 115 | 160 8 [250.250 [254 | 10 750 | aoa10 | 750 | 110 | 9000 | _@ | 216x275 | 279 10 25 | 60935 | 25 | 135 | 8700 ee | 300x300 | 305 16 900 | 50-145 9 320x320_| 325 18 960 | 45-140, 8 350x350 | 355_| fase +1050 | 45-130 12 aaixaai | 396 20 tras) 40-120 2 [400 405 20 | 1200 | 40-115 12 " For maximum pile length only Norminal | Available [Reinforcement Maximum Stuetural] Recommended | Maximum Stucurl | Recommended cass | “Sue | ‘Lengths |" ares |" Wortinguoad | ‘AelWorking |"""WaringLoed | Al Working Ltr crm] me) Tonnes {ad Tonnes Tonnes teed tonne [150 x 160 25 eee| [sx 176 | 3 % 35 45 200x200 | 45 co | | 235205 6 5 250x250 ee stander [-275%275 300x300 z lise 320x920 2350x960 2381x961 2 175x176 are EAU 200x200 | Cee | mixx | 3.6.8 | =e | 250x250 [3.6.9 Cara | cusemiea| 275x276 [3.6.9.1 | e28 105 | 300x300 |3,6,9,12| 604 | 126 | [320x320 |3,6,9,12 | 804 anes: 130 1 | 350x360 |8.6,9,12) 905 169 145 165 wei xaet |8,6,0,12| 1257 jana ell sabe a Sion t, l 400x400 |3,6,9.12 | 1257 | 221 195 245 Notes : i ‘+ Maximum and recommended axial working loads shown are only theoratical structural capacitis of piles. ‘Actual working capacities are dependent on soll conditions and other considerations, but shall not exceed maximum ‘axial working loads shown Ine eur poy to ontnusuly ew nd improve roduc arto sgn, Intmaton ahs lett Mertee suet ocho vathout re. HUME CONCRETE MARKETING SDN. BHD. sen1 ‘A Member ofthe Hong Leong Group Level 2, Bangunan PanGlobal, 1A. Jalan Tandang, 46050 Petaling Jaya, PO. Box 21, 46700 Petaling Jaya, Selangor Darul Ehsan, Malaysia. Tel: 03-7783 2068 (General Line} / 03-7786 6262 (Hotline) Fax: 03-7785 1823 (Markoting) | 08-7782 7220 (Spacial Projects Unit) E-mail: hom@humeconcrete.com.my Hume Concrete Factories : Beranang uartan Pasi Gudang Pra 10165, Bornang industial Estate, Lot, Somaru industrial Esato, Pot 244, Jalan Emas, Lot 298239, Lorong Porusahaan 8, 43700 Borenang, Kaan, 25960 Kuantan, 8700 Pasie Gudang, roi Industrial Esato, Selangor Darul Ehsan Tok ag eg vasizc Fasc 02-8766 7290 Panang Datl Mak. To 08 509 4277862 Fx 09-566 3668| sarehenae taciniheasaenintl aa ae donor Darl Tein, Jee 07-261 26900000 Fasc07-2512677 13000 Pai, Penang Toros. 390 o71004e8 Faxc003995471 Sabah Sth, Turan Road, POBox 10239, 18900 Kota Kinabalu, Sabah “es 098-420 32526 | Fave 8822473

You might also like