Perhitungan 1

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

Data Design

fluida panas fluida dingin


massa udara
tekanan 134 kg/cm2G 2.06 kg/cm2G
suhu masuk 10.7 oC -9 oC
suhu keluar -5 oC -9 oC
luas area - 1052 m2
Q design - 7750000 kcal/h
∆H - 301.3099 kcal/kg

∆T LMTD 9.8474 Q
84946.7968
Ud 748.1057
Rd 0.0002
Uc 879.7323

Data aktual
fluida panas fluida dingin

tekanan - kg/cm2G 1.68 kg/cm2G


suhu masuk 5.53 oC -11.7 oC
suhu keluar -10.4 oC -11.6 oC
luas area - 1052 m2
massa ammonia (m) - 5740 kg/h
∆H - 303.3518 kcal/kg
tekanan 1.68 kg/cm2G

Q m x ∆H
1741239.332 45719.1

∆T LMTD
7.2440

Ud
228.4882691987

Rd
0.0032398828
5.74 m3/h 1000

You might also like