Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

16C97 Door Lock Instruction Manual

One Product Features:


Content
·Main board adopts Philips CPU and microcomputer chip-level.
1. Product Features.....................................................2 ·TDG anti-theft cylinder(easy to replace of anti-theft mechanical cylinder)

2. Technology and Specification..................................2 ·Modern and fashion style


·Optional unlocking modes(Password or card, password only, card only, card+password)
3. Function and Operation........................................2-5
·When illegal attack happened lock password to protect and give a alarm.
4. Size.........................................................................6 ·Can manage cards by passwords
·With function of anti-peeped passwords.
5. Hole Map.................................................................7
·TDG anti-theft cylinder can replace of normal standard anti-theft door lock cylinder.
6. Notes......................................................................8
Two Technology Specification

Available cards RF card


Cards testing method Microwave test, reliable and advanced
Password numbers 200 groups
Card numbers 780 pcs
Power supplier DC4.5V~6.5V, 4pcs 1.5V“AA” alkaline batteries
Static current < 15μA
Dynamic current < 150mA

Have sound lighting notice when voltage low


Low voltage warning function
than 4.8V,, still can open 50 times.

Electric actuator DC micro motor


Available cylinder Standard anti-theft door use TDG electronic
cylinder

Service life More than 300,000 times

Three Function and Operation


Product Original Status
Initial user password is "123456".
Initial management passwords is “0000” (Management passwords cannot unlock the lock).

1 2
1). Change the management passwords. 6). Unlock Mode and Mode Setting
“*7” + management passwords + # + new management passwords + #. Setting finished. Remarks: Default Mode is Mode (1).
Remarks: New management passwords will replace the old one.
Mode(1): Password mode or Card mode. Unlock the lock by any valid password or card.
Atten.: The correct operation of “*7”:Use one finger press *, then another finger press 7, Setting: “*0” + management key + # + 1 + 0 + #.
then release both buttons at the same time. Same operation for “*8”, “*9”, “*0”, “*1”.
Mode(2): Coordination unlocking of approval by valid user card and valid user password.
2). Change the management card. It is OK to read the valid card first or input the valid password first.
“*7” + management passwords + # + new management card + #. Setting finished. Setting: “*0” + management key + # + 1 + 3 + #.
Remarks: New management card will replace the old one.
7). Passage Mode
We named “Read management card” or “Input management passwords” to “management Passage Mode Setting: “*0” + management key + # + 2 + 1 + #.
key” in the following instructions. Passage Mode Open: “*0” + management key + # + 2 + 1 + # + user card or user passwords
+ “*1” (one sound). Setting finished.
3). Add new user cards or new user passwords. Based on above open mode, continue to touch user card or input user passwords or press
Add new user cards: “*8” + management key + # + new card + #. “#” to close passage mode.
Repeat for more user cards.
8). Others
Add new user passwords: “*8” + management key + # + new passwords + #. a. Alarm whistle 10 times after inputting error password 3 times, alarm whistle 10 times and
Repeat for more user passwords. keyboard will be locked for 1 minute after error password 7 times.
b. Protect your passwords by using one group of numbers which includes the user
The function can input many user cards continuously, or input many user passwords; passwords: When you use passwords to open door, input passwords as per method: xxx +
The function will exit automatically after 6 seconds, or you can press “#” to exit operation user passwords + xxx + “*#”. It means that after press button“*#” to confirm, you can add
directly. several unrelated passwords in front or after user passwords.
Remark: User passwords must be entered and must be within the last 31 numbers.
4). Delete user cards or user passwords. c. Factory setup: Dismantle batteries cover of back panel, press ADEL button for 3 seconds,
Delete user cards: “*9” + management key + # + user card + #. then red lamp lighting, and make a long sound, the system start to recover factory setup,
Repeat to delete more user cards. memory, all cards and passwords records are completely deleted, finally admin password
is“0000”, passage mode, working mode is mode 1.
Delete user passwords: “*9” + management key + # + user passwords + #. d. Press“*” singly means “cancel”, press “#” singly means “confirm”, press “*#” means
Repeat to delete more user passwords. “confirm”.

The function can delete many user cards continuously, or delete many user passwords;
The function will exit automatically after 6 seconds, or you can press “#” to exit
operation directly.

5). Delete function


a. Factory reset: “*0” + management key + # + 0 + 0 + #.
b. Delete all user passwords and user cards: “*0” + management key + # + 0 + 1 + #.
c. Delete all user cards: “*0” + management key + # + 0 + 2 + #.
d. Delete all user passwords: “*0” + management key + # + 0 + 3 + #.
3 4
9). Identify Indicating Voice Four Size
“do na mi” open lock\close lock
“di” short voice: pressing button voice
“di…”: key or normal opening is valid
“di……”long voice: start to delete lock information
“di”4 times: working mode is not matched
“di da”: valid password or valid card
“di da di da”: password or card setup is valid
“warning alarm” 1 time: password or card is invalid
“warning alarm” 2 time: lock do not close fine
“warning”10 times input error password 3 times
“warning”10 times +1min keypad locked input error password more than 7 times.

5 6
Five Hole Map

Steel Door Hole Map Wood Door Hole Map

Central line Central line


of the handle of the handle

Hole depth
of the strike
Hole depth
plate case
of the strike
32mm
plate case
32mm

Depth of the Depth of the


strike plate strike plate
2.0mm 2.0mm

Central line
Edge line of the door
Edge line of the door

Central line Mortise central line

Mortise central line

7 8
Six Notes:

1. Factory code”123456” is set to facilitate opening door when installation, it will be invalid
after delete all information of lock.
2. Can change the outward or inward opening for cylinder, see pic.

9 10

You might also like