SPECIFICATION SHEET FOR DG SET ALTERNAT

1 IDENTITY
1.1 Tag No :
1.2 Quantity :
1.3 Mounting Location :
1.4 Make :
1.5 Model No :
2 BASIC TECHNICAL PARAMETER
2.1 OPERATING CONDITIONS :
2.1.1 Design & operating Temperature
2.1.2 Operating
Noise levelRH
@ 1 mt. distance from panel
2.1.3 @ Full load
2.1.4 Installation altitude above sea level
2.2 Make & Type
2.3 Model
2.4 Alternator Type kVA Rated kW at 0.8 PF
Rated continuous
2.5 (Lag)
2.6 Rated voltage
2.7 Rated Frequency
2.8 Rated Speed
2.9 No.of phase
2.10 Neutral
2.11 Rated continuous load current
2.12 IP class of enclosure
2.13 Class of insulation
2.14 Type of internal Heating Mechanism
2.15 Standard temperature rise
2.16 Efficiency at rated voltage & 0.8 p.f.
2.14.1 i. Full load
2.14.2 ii. 3/4 load
2.14.3 iii. Half load
2.15 Connection diagram
2.16 Resistance in Ohms
2.16.1 Main Stator
2.16.2 Main Rotor
2.16.3 Exciter Stator
2.16.4 Exciter Rotor
2.17 Governing specification
2.18 Overload capacity
2.19 150 % Overload capacity
2.20 Class of Insulation.
2.20.1 Main Stator
2.20.2 Main Rotor
2.21 Alternator AVR
2.21.1 Type
2.21.2 AVR Voltage regulation.
2.21.3 Sensing
load at PF from 0.8 Lag to Unity with 4 %
2.21.4 Speed governing of engine
2.22 Damper winding
2.23 Direction of Rotation
2.24 Bearing Detail
2.25 Bearing lubrication
2.26 Waveform Distortion on No Load
2.27 Waveform Distortion on 100% Load
2.28 RF / Telephone interference
2.29 Quadrature Droop Kit & Setting
2.30 Unbalance load
2.31 Transient Voltage Dip on FL
2.32 DIGITAL GENSET CONTROL
2.32.1 Make
2.32.2 Model
2.32.3 Auto Synchronization Facility
2.32.4 Momentarily Synchronization With Grid
2.33 Short circuit withstands capacity
2.33.1 3 – Phase short circuit.
2.33.2 2 – Phase Short circuit
2.33.3 1 – Phase short circuit
2.34 Fault Level
2.35 Excitation System protection
2.36 Filter Unit
2.37 Droop CT
2.38 Space Heaters
2.39 Bearing Temperature sensor & Scanner
2.40 Type of cooling system
2.41 Neutral
Maximum Grounding
ac wave total harmonic
2.42 distortion
2.43 Telephonic Influence factor
2.44 Telephonic harmonic factor
2.45 Excitation type
2.46 Excitation system
2.47 Phase Rotation
2.48 Weight
2.49 Design
2.50 Stator
2.51 Stator Winding
2.52 Rotor
2.53 Operating Power Factor
2.54 Ramping Time
2.55 PMC Voltage controller
2.56 Automatic Voltage Regulator Range
2.57 Waveform Distortion
2.58 Steady State X/R Ratio
2.59 Short Circuit Ratio (1/Xd)
3 PROTECTIONS
3.1 Under Voltage Relay ( 27 )
3.2 Instantaneous Overcurrent Relay ( 50 )
3.3 Over Current
Voltage Protection
restrained Relay ( 51
o/c protection )
Relay
3.4 (51V)
3.5 Ground o/c protection Relay (51N)
3.6 Over
UnderVoltage
/ Over Relay ( 59 )protection Relay
Frequency
3.7 (81u/o)
3.8 Master Lock out Relay ( 86 )
3.10 Synchronizing Protection Relay
4 Cables
4.1 Cable entry
4.2 Cable Grade
4.3 Cables for CT secondary wiring
4.4 Cables for PT secondary wiring
4.5 Cables for auxiliary circuit (230V AC)
4.6 Cables for control circuit (230V AC)
5 ACCESSORIES
5.1 Space
BTD andheater
RTD in
forAlternator
Winding protection with
5.2 Alarm & Trip Function
5.3 Termination extended box
ET ALTERNATOR
VENDOR TO CONFIRM

VENDOR TO CONFIRM
VENDOR TO CONFIRM

VENDOR TO CONFIRM

VENDOR TO CONFIRM