Download as pdf
Download as pdf
You are on page 1of 20
FLOOR STANDING TYPE DUCT TYPE COOLING ONLY 50Hz (R-4108| 4 ac i DUCT TYPE FLOOR STANDING TYPE DIRECT AIR BLOW TYPE DUCT CONNECTION TYPE responsible corporate citizen has taken utmost importance, Even when selecting air conditioners, a new model featuring HFC R-410A refrigerant could be the perfect step in promoting your corporate image. Product Line Up [r-4108) FLOOR STANDING TYPE NEW) 5 10 oe 147 17.6 235 29.5 Capacity 50,000. 0,000. 0,000. 700,000 12.500 15,100 20,200 25,200 DIRECT AIR BLOW | TYPE E | (sccm ons = |\crenem Patt | Indoor unit] FVGROSNV1 FVGROBNV! FVGROBNV! FVGRIONVE 3 door wait| ——RUROSNYT RURDGNYT URGGNYE URVONY! 5] DUCT CONNECTION 8|TYPE g | cee = eee Pu? | Indoor unit FVPGRIONY? Dudoor a HURIONYE OUTDOOR UNIT o” o é ae) 6 6 J iil Duct TYPE | Cooling only _ 5 6 8 10 i 78) 235 298 Capacity 30,000 700,000 20,200 25,200 DUCT TYPE —— (Sees Sines Peo 8.4 ) Indoor unit] FDROSNY1 FOROBNY1 FDROBNY1 FDRIONY1 sora | —— RUROSNVE TRURGENYT UROGNYE RUATONYT OUTDOOR UNIT o” oO" E 8 8 ‘as ed lg saps a on lg rs Ra ap, APCD, OND aaa EDR, aN FO cr rte a 1 18 20 35.2. 46.9) 52.8 58.6. 20.008 "60.00 30.000 200 30.200 49.900 45.400 400 FVPGRISNYt EVPGRISNYt FVPGRIBNYt FVPGR20NYt BUBLGNYE BUBZONYE BURISNYE AUAIBNYT 50Hz a 1 18 20. 35.2. 46.9 52.8 58.6 “120.000. "160.000. 180,000 200,000 49.300 45.400 400 FDRISNYt EDRISNYt FDRISNYt FDR20NY+ BURIGNY? BURISNY? BURIGNY? BURZONYI Nice, cool air in the factory or in the cafeteria oder ea nd Flexible design HM FLOOR STANDING TYPE DIRECT AIR BLOW TYPE Enhanced varieties of factory modification and optional accesories Stands med! f] ‘Modi wiring for ceniral control ; Soot Ba fase natn ‘Grange en maior ae play i chao epee Ta B FvaRionvt Front eucton nigh elegy War Graber igh fencer Stata DUCT CONNECTION TYPE igh fconey er chamber : Vie ns Freeh art Fas ea Dan pune = emote sera Terrier raion A = ‘lireah a appeton ==>. . a Texan 7 Ey afo}o} o ‘ow ctor ep 15° epleaton Sha ong ipa 70m alton sie ‘nal eal dpa (cnr einer ONO ner TaD rans snoler ACI Trion Teen Conroe eseorest Thos ONOFF eanaior cod Remo sereor herr er surion a rasa / E| RURIONYI OT FvpGRtony1 HM DUCT TYPE Quiet Operation | Equipped with scroll compressor for l RURIONYI quiet operation FDRIONY1 ‘Smooth running, low vibration, low operating [Sandee ao | s16y rrurosnv | 59 a8 | 60 cB uta rrunoenys | 59 a8 | 60 a8 ee and great reliability. Easy operation Digital remote control comes standard with indoor unit. “Temperature setting is possible by button operation. The set, temperature is conveniently displayed on the LED. Foor slaring ype (Sundar acersny) Ppeee @- ol a @ Doworewon —APTamp-eetna denn Dconarasersprton np Dfanewton——-Seconuton ‘Bran epeson Btons seers BLED supa, Duet yee pera accesso) (2 cergeetr nar ine lane Tengen se oper seing Coline me Mote swing Corpse inseam Design flexibility Designed for long refrigerant piping. 50 m maximum length and 30 m maximum level diferenco, to cover medium: and large-scale bulding needs. Outdoor unit root Installation possible for plenty of leeway. Refrigerant pre charged for up to 7.5 metres sm Asonablrfigerant pe lng an ive erence Pecapel Merah 4-direction piping affords more freedom Of layout omar wrunesvaen Piping can be run from the front, bottom, right or rear surface according to how the units installed. Incase of RUROB-20N, piping can be drawn out in two irections-ront, and under sid. Durability Heat exchange fins provided with anti-corrosion treatment To ackiove increased durability by improved resistance to sat corrosion and atmespherlepolon, coated PE fins (with special acry pretreatment) are used for the heat exchanger of the outdoor unit. (pple aoe ats) Space savings Installation space is saved thanks to a more compact outdoor unit. This also makes it easier to install. remand =a Lo ba » | 25400 fm oan (Mee SPECIFICATIONS FLOOR STANDING TYPE DIRECT AIR BLOW TYPE —— ee few =f —= —— z Fan [ Dive =e _ co a a FLOOR STANDING TYPE a a = = = = = Ses 2 yeaa 2a a ‘Machine weight ia 150 ~ 180. a pen [Covwee e some en Vax Rent aprg lnah m 30 Tequvaere engin TOM DUCT TYPE - Motor output [AW Soe eve7 7507S I 30D fs s Z : Fan Performance FLOOR STANDING TYPE DUCT CONNECTION TYPE varcniun rvanisuy + "“eetene "| 4| =m a] ote Py + Po al ad i! ie a Art a(n) — EE Olena Ree Is SS, gz x Es” 7S lems i i. ee Bf Pat oa Ji aes DUCT TYPE a steal state pressure (mmts0) (mo) tema stati press xcema stati pressure (Pa) Eternal state pressure (Pa) ‘iow ao (rin) eee ‘Arow ate (vim) AIOE 26 soatca a sauna ™ sa1a6-28 Airlow rate rin) orion teal tate posure (nmb:0) oe eg Exel tai praeute (Pa) sternal stale prssure (Pa) Difow ao (rin) i) ers le-225-90 los 0098 loa 280.20 ies fe08 P1702 2B-250 2B fe0.38 ‘io rate (rei) Wiri 1 Pipi IIFLOOR STANDING TYPE DIRECT AIR BLOW TYPE RUROSNOSN IIFLOOR STANDING TYPE DUCT CONNECTION TYPE IIMENSIONS — writzmm IIFLOOR STANDING TYPE DIRECT AIR BLOW TYPE FVGROSNVI FVGROGNV1 FVGROBNV1 Ae 2 Frenne [720 ran a9 | ora gui pipe conn. (6) 12207 braning ® Gas pipe con. (0) 12207 brazing © Uppor ean ut P 1B ital head) €) Powor surly & cont! wie rako pial remota conor FVGRIONVI @ Liuld pipe con. 0 127) 12207 brazing rn. (@ 288) C1220T basing ran out (PS 1B nora oad) (@ Powersupply & contrl wre rake & bigtaromote conte 10 DIMENSIONS — writ:mm IIFLOOR STANDING TYPE DUCT CONNECTION TYPE FvGRIONY 3 © Digital remote controller im i ah I q | FVPGRISNY1 - e]o le [+ [ee FVPGRISNY1 a. a [as [oe [a ee FVPGRI8NY1 t FvpGR20ny1 4] a 4 © Lid po comm. (K) Cr2@0T bang B Gaspie com. (L) Ci20T bazna Uppar ran out? 18 ra eas) Ly h Lowa att 18 nral eas} i 1 Power supp & contol wwe mate € Digtl emote conor Duct TYPE FoROSNY1 pP “| te i gion stn (098) Qouspeconesen oie Sor pou son 5 8 oalnen Seo reel rove Boece Spear pucr TYPE FOROENY a j 4 6 iene @aus ape crmecten 098) BesiseeeanetentsSes Sen poscinecton 318 moral ves . Semel eT 1 Bower supoy ; Soeur ae a] 2 DIMENSIONS (unt: over ee eT 1} 4 1 iT t = i ll = ll | I qt a I [== | == | el] | tS) |) ye EL IFDROsNy®] ——_[FORYON) | ee t oo (D Liquid pipe connection (9 12.7) pea een Sees Duct TYPE FDRIQNY1 /15NY1 / 18NY1/20NY1 Bean (roRiaNvi] [rontenyi re [FORISNYA] [FOR20NV1], Fo ie rs oe a0 [rae Joe Fos ines rs oe an] 0] rn [ra] 2 [os FORT atte sez oo [no [za] se [os Devaporaor ar inet connection BE vaporatr aout oonocton Leu pipe comoston Gas pipe connacon ) ‘®Dran pe conmacon "(P5 1B interna esd @Eamtemina Power spp intake DTha ols france bots ‘oUTDOOR UNIT RUROSNY1 RUROSNY1 axe poscomeatin Buzuepen come, (Bsoneeporin ea {Baraniegtemns Ws bowen 'Baergent gorge (BSonernnay wg ke Sounporconstin ‘OUTDOOR UNIT RUROBNY1 RURTONY1 ssxzasemoveng ne om o_o Sie tl Frome 20 pre 1) Bang comecten sso unserem comctongr barge cmeconcue {Borers {BSeworane nla) 12 eee gre et (Broeerane ang et 1 dearer hare oo) meTEpo AE ome fsa] mane Sree rociens en [zr ‘30 agen) 14 DIMENSIONS wit mm ‘oUTDOOR UNIT RURISNY1 RURISNY1 — eset RURT8NY1 RURZONY1 io| 8 fea a Co CI —o SS SS)! noe SS 2 ugisponcomastonset Nise aa Ferran Sa ne Fs ‘Bim ppe crc thew The Ons or Fan The Seasons. andegserin 2oae poe {Pownce ean oe) Be Bg eorten (9 fowrenc rang Stent ee Stowsevcng em © sResae on [auras [fen Space required for indoor unit installation (Unit: mm) FVGROSNV1 FVGROSNV1 FVGROaNV1 FVGRIONV1 FVPGRIONY1 FVPGRISNYt FVPGRISNY1 FVPGRIBNY1 FVPGR20NY1 Space required for outdoor unit installation — (unit: mm Il For RUROSNY1/06NY1 When there is an obstruction on the inlet side When the overhead space is open 1. For single unit installation ‘When there is an obstruction only on the inlet side When there are obstructions on both sides 2. For series installation (more than two units) When there are ‘obstructions on both sides When there is an obstruction in the overhead space 1. For single unit installation ‘When there is an obstruction on the inlet side acoemcson When there are obstructions €n the inlet side and both lateral ses 2. For series installation (more than two units) When there are obstructions fon the inlet side ang both lateral sides When there is an obstruction on the outlet side ‘When the overhead space is open 1.Forsingle unit, installation 2. For series installation (more than two units), ‘When there is an obstruction in the overhead space 1. For single unit installation 2. For serias installation (more than two units) When there are obstructions on both the inlet and outlet sides bscton on hs outta gna han tstucton on the out id) When the overhead space is open 1. For single unit installation 2. For seri instalation (more than two units) I For RUROSNY1/10NY1/13NY1/15NY1/18NY1/20NY1 (Poa gency bok or inalaon pat) For single unit installation For installation in rows Pattern 1 Pattern 1 em | Fen) sane Pattern 2 Pattern 2 wore | [Re | own Pattern 3 Pattern 3 Y Y For centralized group layout Patter 1 Sao Sn ZF rom) | anne tof oe dem Z Pattom 2 Ban 4 Free | [oan Fn) Fra | seme "cat cea a Shay manos ls teh sac apart pas boon an ‘me nsw eae an cues nn ow pte “Shoah ee el pn the on na on te pte ora walk ceed st Waring ® Ask a qualified installer or contractor to install this product. Do not try to install the product yourset Improper installation can result in water or refrigerant leakage, electrical shock, fre or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. * Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. 7 Cautions on product corrosion ») 1. Air condioners should not be instaled in areas where comosive gases, such as acid gas or alkaline gas, are produced 2. the outdoor units tobe installed close to the sea shore, droct expasure tothe sea breeze should be avoided. If you need to install the outdoor unit close tothe sea shore, contact your local istrbutor. ) PT DAIKIN AIRCONDITIONING INDONESIA Head offen ‘outs “iia /

You might also like