S-ROM Stem System

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

S-ROM

T O TA L HIP SYSTEM

Femoral Stems and Proximal Sleeves


Stem Diameter Femoral Necks Femoral Necks Femoral Necks Proximal
& Lengths Standard Lateralised Calcar Replacement & Lateralised Sleeves

Neck Length 30 36 42 30 + 4 LAT 36 + 8 LAT 36 + 21 CR 36 + 21 CR + 4 LAT 36 + 21 CR + 8 LAT Size Small Large XXLarge
Lateral Offset/Vertical Drop 28/21 32/25 37/29 32/21 40/25 32/46 36/46 40/46
Offset listed assumes a +0 Femoral Head

12 x 6 115 mm
12B l l
N Standard 12D l l

12 x 7 115 mm
12B l l
N Standard 12D l l

14 x 8 130 mm 14A l l
N Standard
14B l l
14 x 9 130 mm
14D l l
N Standard 130 mm 130 mm
14F l l
NLR Long 205 mm 205 mm

16 x 11 150 mm
16B l l
N Standard 150 mm 150 mm 150 mm 16D l l
NLR Long 205 mm 205 mm 205 mm 16F l l l
LR X-Long 240 mm 18F* l l l
LR XX-Long 300 mm *18F OD for 16 x 11 Stem

18 x 13 160 mm
18B l l
N Standard 160 mm 160 mm 160 mm 160 mm 160 mm 18D l l
NLR Long 215 mm 215 mm 215 mm 18F l l l
LR X-Long 255 mm 20F* l l l
LR XX-Long 315 mm *20F OD for 18 x 13 Stem

20 x 15 20B l l
N Standard 165 mm 165 mm 165 mm 165 mm 20D l l
NLR Long 225 mm 225 mm 225 mm 20F l l l
LR X-Long 270 mm 22F* l l l
LR XX-Long 325 mm *22F OD for 20 x 15 Stem

22 x 17 165 mm 165 mm
22B l l
N Standard 165 mm 165 mm 22D l l
NLR Long 230 mm 230 mm 230 mm 22F l l l
LR X-Long 275 mm 24F* l l l
LR XX-Long 325 mm *24F OD for 22 x 17 Stem

24 x 19 175 mm 175 mm 175 mm 175 mm


N Standard 24B l l
NLR Long 230 mm 230 mm 230 mm 24D l l
LR X-Long 275 mm 24F l l l
LR XX-Long 325 mm

SPA Conical Sleeves are available in sizes:


See reverse for key information and dimensions 14A, 14B, 14D, 16B, 16D, 16F.
Fax: +44 (113) 272 4191
Tel: +44 (113) 270 0461
0086 England
Leeds LS11 8DT
St Anthony’s Road
DePuy International Ltd
Cat No: 9068-93-000
Product Size Selection Wallchart
© 2001 DePuy International Limited
Femoral Prostheses S-ROM® is a registered trademark and ZTT™ is trademark of Johnson and Johnson
This publication is not intended for distribution in the USA
stiffness associated with end-stem thigh pain.
• Distal slot in the coronal plane to reduce bending
flutes for a high degree of torsional stability.
• Geometrically shaped proximal sleeves and distal
stem and sleeve combination.
miller to provide a precisely machined cavity for each
• Femoral preparation with reamers and a triangle
vide additional lateral offset.
have a selection of neck lengths and necks that pro-
the proximal and distal femur of each patient. Stems
ly to achieve a combination to optimally "fit and fill"
• Ability to select stem and proximal sleeve independent-
to provide maximum joint stability.
proximal bone with independent version selection
• Enables implantation into the best available host
provide numerous of "fit and fill" possibilities.
sleeves (HA or porous coated) that may be selected to
• For each stem size there are up to ten proximal
mal sleeves for cementless application.
• Porous (ZTT™) or hydroxylapatite (HA) coated proxi-
• A one piece wrought titanium alloy stem
SYSTEM HIP T O TA L
®
S-ROM
W a l l c h a r t
® ®
S-ROM
T O TA L HIP SYSTEM
S-ROMT O TA L HIP SYSTEM
Femoral Prostheses Femoral Prostheses
Stem Diameter Stem Neck Proximal Sleeve
Dimensions Dimensions Dimensions Dimensions
Minor • Neck Length is the nominal
Diameter
Major distance measurement from the
Diameter stem shoulder to the centre of
Proximal the head for +0 Heads.
Diameter SML LRG SML LRG SML LRG XXL SML LRG XXL
• Included Angle is the angle
formed where the neck meets
the stem. This is 135Þ on all
Distal Distal Proximal
Diameter Diameter Diameter S-Rom® Stems.
(Minor) (Major)
• Lateral Offset is the horizontal
6 mm +1 mm 12 mm
Stem measurement from the centre
7 mm +1 mm 12 mm
Length of the head to the centre of
8 mm +1 mm 14 mm
the stem. ‘B’ cone ‘D’ cone ‘F’ cone ‘F oversized cone’
9 mm +1 mm 14 mm
11 mm +1.25 mm 16 mm • Vertical Drop is the nominal adds 3 mm to the adds 5 mm to the adds 7 mm to the adds 9 mm to the
13 mm +1.25 mm 18 mm distance from the centre of diameter of the stem diameter of the stem diameter of the stem diameter of the stem
15 mm +1.25 mm 20 mm Distal the head to the shoulder of
17 mm +1.25 mm 22 mm Diameter the stem.
The extent of the triangle on the
19 mm +1.25 mm 24 mm Size Small Large XXLarge Available Neck Lengths by
proximal sleeve is proportional to
12 8.5 mm 12.5 mm 16.5 mm Material and Diameter
The major diameter includes the the proximal diameter of the stem.
distal flutes. The distal diameter 14 9.5 mm 13.5 mm 17.5 mm
corresponds to the minor diameter Cobalt Chrome 22.225 mm +0
16 10.5 mm 14.5 mm 18.5 mm
Cobalt Chrome 26 mm +0 +6
18 11.5 mm 15.5 mm 19.5 mm
20 12.5 mm 16.5 mm 20.5 mm Cobalt Chrome 28 mm +0 +6 +12
22 13.5 mm 17.5 mm 21.5 mm Cobalt Chrome 32 mm +0 +6 +12
24 14.5 mm 18.5 mm 22.5 mm
Zirconia Ceramic 28 mm +0 +6
Alumina Ceramic 28 mm +0 +3 +6
Femoral Head
Dimensions Alumina Ceramic 32 mm +0 +6
+0 head +3 head +6 head +12 head
adds 0 mm to the neck adds 3 mm to the neck adds 6 mm to the neck adds 12 mm to the neck
length and 0 mm to the length and 2 mm to the length and 4 mm to the and 9 mm to the vertical
vertical drop and lateral vertical drop and lateral vertical drop and lateral drop and lateral offset.
offset. offset. offset.