Re Yw ST Yw FL MP PVCDKPVC 500v
CU/PVC/OSCR/PVC
Instrumentation Cables PVC DK PVC 500 V
www.halleycables.com
PVC insulated, collective screened, PVC sheathed cable
Construction:
Conductor : plain copper wire, stranded.
Insulation : PVC compound, 105° C.
Core identification : black / blue cores numbered 1-1, 2-2,… Upon request: colour coded according to IEC 60189-2. Other core
configurations manufactured upon request.
Pair : two conductors twisted to a pair.
Lay-up : pairs laid up in layers of optimum pitch.
Separator : polyester tape.
Screen : AL-PES tape over stranded tinned copper drain wire 0,50 mm².
Outer sheath : PVC compound, 105° C.
Applications:
These cables are used for transmission of analogue and digital signals in instrumentation and control systems at
chemistry and petrochemistry industry plants, power plants, natural gas and petroleum plants, etc... .
Instrumentation cables are not allowed for direct connection to a low impedance source, e.g. public mains
electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not
recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on
racks, trays, in conduits.
HALLEY CABLES, Str. Siderurgistilor, nr. 9, 800364, Galati, Romania HALLEY CABLES and HALLEY CABLES logo are registered trademarks of HALLEY CABLES SRL.
The above values correspond to the manufacturer's specifications and are not guaranteed. Tel. +40 236 319 000 Fax. +40 236 319 085 Created by HALLEY CABLES SRL March 2015.
RE-Yw(St)Yw-fl MP 105° C
CU/PVC/OSCR/PVC
Instrumentation Cables PVC DK PVC 500 V
www.halleycables.com
PVC insulated, collective screened, PVC sheathed cable
DIMENSIONS
No. of cores x cross section Approx. outer diameter Copper weight Approx. cable weight
mm² mm kg/km kg/km
1x2x0,50 6,2 14 40
1x2x0,75 6,6 19 45
1x2x1 7,0 24 55
1x2x1,3 7,5 30 65
1x2x1,5 7,8 34 70
2x2x0,50 9,2 24 70
2x2x0,75 9,8 34 85
2x2x1 10,5 43 95
HALLEY CABLES, Str. Siderurgistilor, nr. 9, 800364, Galati, Romania HALLEY CABLES and HALLEY CABLES logo are registered trademarks of HALLEY CABLES SRL.
The above values correspond to the manufacturer's specifications and are not guaranteed. Tel. +40 236 319 000 Fax. +40 236 319 085 Created by HALLEY CABLES SRL March 2015.
RE-Yw(St)Yw-fl MP 105° C
CU/PVC/OSCR/PVC
Instrumentation Cables PVC DK PVC 500 V
www.halleycables.com
PVC insulated, collective screened, PVC sheathed cable
DIMENSIONS
No. of cores x cross section Approx. outer diameter Copper weight Approx. cable weight
mm² mm kg/km kg/km
HALLEY CABLES, Str. Siderurgistilor, nr. 9, 800364, Galati, Romania HALLEY CABLES and HALLEY CABLES logo are registered trademarks of HALLEY CABLES SRL.
The above values correspond to the manufacturer's specifications and are not guaranteed. Tel. +40 236 319 000 Fax. +40 236 319 085 Created by HALLEY CABLES SRL March 2015.