Appendix F: SEL-701 Relay Settings Sheets
Appendix F: SEL-701 Relay Settings Sheets
Appendix F
SEL-701 Relay Settings Sheets
Relay Settings
(Blank Sheets)
General Data
Relay Identifier
Range: 20 Characters RID =
Terminal Identifier
TID =
Range: 20 Characters
Phase (IA, IB, IC) CT Ratio
Range: 1–6000 to 1 CTR =
Phase CT Secondary Rating
Range: 1 A, 5 A ITAP =
Neutral (IN) CT Ratio
Range: 1–6000 to 1 CTRN =
Neutral CT Secondary Rating
Range: 1 A, 5 A INTAP =
Phase Rotation
Range: ABC, ACB PHROT =
Nominal Frequency
Range: 50, 60 Hz FNOM =
Date Format
Range: MDY, YMD DATE_F =
Demand Meter Time Constant
Range: 5, 10, 15, 30, 60 min DMTC =
Phase (VA, VB, VC) VT Ratio
(Hidden if voltages not included)
Range: 1–6000 to 1 PTR =
Phase VT Connection
(Hidden if voltages not included)
Range: D, Y DELTA_Y =
Single Voltage Input
(Hidden if voltages not included)
Range: Y, N SINGLEV =
Standard Alarm Contact Operation
STDALARM
Range: Y, N =
RTD Type
Range: PT100, NI100, NI120, CU10 RTD11TY =
RTD Type
(Hidden when RTDOPT = INT)
Range: PT100, NI100, NI120, CU10 RTD12TY =
Voltage-Based Protection
Undervoltage (U/V) Elements (Hidden if no voltage option or if
DELTA_Y = Y)
Level 1 Phase-Phase U/V Pickup
Range: OFF, 1–300 V 27P1P =
Level 2 Phase-Phase U/V Pickup
Range: OFF, 1–300 V 27P2P =
Range: 0.00–400.00 s
Negative VAR Trip Pickup
Range: OFF, 30–2000 VAR; ITAP = 5 A
NVARTP
OFF, 6–400 VAR; ITAP = 1 A
=
Positive VAR Trip Pickup
(Hidden if NVARTP = OFF)
Range: 30–2000 VAR; ITAP = 5 A
PVARTP
6–400 VAR; ITAP = 1 A =
VAR Trip Time Delay
(Hidden if NVARTP = OFF)
Range: 0.00–400.00 s VARTD =
VAR Element Arming Delay
(Hidden if both NVARAP and NVARTP = OFF)
VARDLY
Range: 0.00–15000 s
=
Range: 0.05–0.99 =
Power Factor Trip Time Delay
(Hidden if 55LDTP = OFF)
Range: 0.00–400.00 s 55TD =
Power Factor Element Arming Delay
(Hidden if both 55LDAP and 55LDTP = OFF)
Range: 0–15000 s 55DLY =
Output Configuration
Analog Output Settings
Analog Output Signal Type
Range: 0–1 mA, 0–20 mA, 4–20 mA AOSIG =
Analog Output Parameter
Range:%Load_I Percentage of Full Load Current
%THERM Percentage Thermal Capacity
WDG_RTD Hottest Winding RTD Temperature
BRG_RTD Hottest Bearing RTD Temperature
AVG_I Average Phase Current AOPARM
MAX_I Maximum Phase Current =
Analog Output Full Scale Current
(Only shown if AOPARM = AVG_I or MAX_I)
Range: 0.5–80.0 A; ITAP = 5 A
0.1–16.0 A; ITAP = 1 A AOFSC =
DM1_0 =
DM2_1 =
DM2_0 =
DM3_1 =
DM3_0 =
DM4_1 =
DM4_0 =
DM5_1 =
DM5_0 =
DM6_1 =
DM6_0 =
Antibackspin Setting
Antibackspin Starting Delay
Range: 0–60 min ABSDLY =
DM2 =
DM3 =
DM4 =
DM5 =
DM6 =
RST1 =
SET2 =
RST2 =
SET3 =
RST3 =
SET4 =
RST4 =
OUT2 =
OUT3 =
Breaker Failure Initiate
Range: SELOGIC Control Equation BFI =
SER2
Range:24 Relay Word bits, separated by commas.
SER2
Use NA to disable setting.
=
SER3
Range:24 Relay Word bits, separated by commas.
SER3
Use NA to disable setting.
=
SER4
Range:24 Relay Word bits, separated by commas.
SER4
Use NA to disable setting.
=
Alias Settings (Hidden when EALIAS = N, ALIAS# > EALIAS setting are hidden.)
NOTE: Relay Word bit (space) Alias (space) Asserted text (space) Alias and text strings
can each be up to 15 text characters. Asserted and deasserted text strings are not
required. Use NA to disable setting.
ALIAS1 =
ALIAS2 =
ALIAS3 =
ALIAS4 =
ALIAS5 =
ALIAS6 =
ALIAS7 =
ALIAS8 =
ALIAS9 =
ALIAS10 =
ALIAS11 =
ALIAS12 =
ALIAS13 =
ALIAS14 =
ALIAS15 =
ALIAS16 =
ALIAS17 =
ALIAS18 =
ALIAS19 =
ALIAS20 =