Installation, Use and maintenance Manual
I. GENERAL
The Manufacturer has made every effort during the design WARNING
and construction stages to make its products completely CAUTION FOR ELECTRIC SHOCK/RISK OF BURN/PROPER
free of risks when correctly used. Note however that INSTALLATION
accident prevention and safety regulations stipulate that n Non-professionals are not allowed to operate. Shut
the users of the product is obliged to ensure that all off the power before maintenance.
persons involved in servicing, installing, handling, using or n Risk of burn, allow lamps/fixture to cool down
selling the products are familiar with the information before handling.
supplied by the Manufacturer and fully aware of any n Risk of falling under incorrect installation.
precautions that must be adopted. Depending on the n The luminaire shall only be used complete with its
circumstances, the instructions in this document must be protective shield.
communicated, together with any other information that
may be necessary, to any Company or person involved in
the installation of GE lighting products.
LAMP REPLACEMENT
Mounting
1. Use two M8 bolts (Not provided by fixture) to fasten
fixture with mounting surface, dimension as below: CAUTION
n Shut off the power before lamp replacement.
Unit:mm
4. Loosen the bolts on front cover, open the front cover, CAUTION
install the recommended lamp properly; n Use the lamp with the same rating as the
indication of product label.
n Replace lamp when it is reaching the life end, to
5. Close the front cover, tighten the screws. avoid system damage.
VI. PRODUCT INFORMATION
PRODUCT BASIC INFO
Input V (Refer To
220/230/240V~ 50/60Hz
Product Label)
Input I (Refer To 2.0 A(400W)
1.3 A(250W)
Product Label) 1.0 A(150W)
HPS
LU400 /T/40(4.6A)
400W LU400 /T/E40(4.6A)
LU400 /XO/T/40(4.5A)
LU250 /T/40(3.0A)
250W LU250 /T/E40(3.0A)
LU250 /XO/T/E40(2.95A)
LU150 /100/T/40(1.8A)
150W LU150 /100/T/E40(1.8A)
LU150 /100/XO/T/40(1.8A)
Recommended GE
Single ended MH
lamps
KRC400/T/H/960/E40(3.5A)
400W
KRC400/T/U/740/E40(3.3A)
250W KRC250/ T/U/740/E40(2.1A)
ARC150/T/U/740/E40(1.8A)
150W
CMH150/TT/UVC/E40(1.8A)
Double ended MH
ARC70/TD/UVC/Rx7s(0.98A)
70W
CMH70/TD/UVC/Rx7s(0.98A)
ARC150/TD/Rx7s-24(1.8A)
150W
CMH150/TD/Rx7s-24(1.8A)
Effective Wind 2
0.13m
Area
11.3 kg(400W) , 10.1Kg(250W),
Weight
8.5 kg (150W),
PRODUCT DIMENTIONS AND OUTLINES