Professional Documents
Culture Documents
Temperature Affect Potato
Temperature Affect Potato
Temperature Affect Potato
Aim:
Scientific Knowledge:
Water Potential:
When two such solutions (one strong, one weak) are separated by a
semi-permeable membrane the water will move from the side with more
water to the side with less until both sides are equal (have reached
equilibrium).
This can be seen in all living cells. The cell membrane in cells is
semi-permeable and the vacuole contains a sugar/salt solution. So when
a cell is placed in distilled water (high water concentration, lower
water potential) water will move across the semi-permeable membrane
into the cell (lower water concentration, higher water potential) by
osmosis, making the cell swell to carry the extra water. This cell is
now referred to as turgid. The opposite of this is where the cell
becomes flaccid, where the cell membrane actually can break away from
the cell wall. If this process were done with the potato cells I would
expect them to increase in length, volume and mass due to the extra
water.
However there will be a point where the water on the inside and
outside of the cell is equal (isotonic). At this point there will be
no change in the length, volume and mass of the potato, as the net
movement of water will be zero, no more osmosis has occurred except to
keep the levels of water approximately balanced. Osmosis will still
occur, but in a very small amount, simply to keep the levels on both
sides balanced, or isotonic.
I have decided to vary the concentrations, to see what affect if any
it will have on the mass, size and weight of the potato cores.
Diagram of Osmosis:
Key:
Semi-permeable membrane
Water molecules
Sucrose molecules.
Predicted Graphs:
Variables:
* PH - The more acidic the solution, the slower osmosis will occur.
The more alkali the solution, the faster osmosis will occur.
* Temperature - The warmer the solution, the quicker osmosis will go.
This is because the molecules will be moving more quickly. Careful
though, if you heat something like a potato chip too much, you will
just kill the cells and no osmosis will occur.
*Surface area of the Potato - This will speed up the rate of osmosis
because there will be more space on the potato fro osmosis to take
place.
*The weighing scales - The weighing scales may not be exact, so I must
leave a leeway of approx. 0.4/0.5 on each result due to the (perhaps!)
inaccuracy of the scales, to produce more precise results.
Safety:
* I will be using a sharp knife, which could injure someone if not
handled properly. Therefore I must not rush with the equipment and I
must handle everything carefully.
* In order to keep the benches clear and clean I will lay paper towels
around where I am working, because even though the substances are
relatively harmless, I will be working with glass and sharp
instruments, so it is safer to do so.
Fair Test:
* I will keep all the other variables the same and constant to make my
experiment fair.
* I will make sure the potato pieces are the same size and have
approximately the same surface area to make sure that osmosis doesn't
occur more due to a larger surface area (see variables).
* I will make sure I use the same size of boiling tube and the same
size corer to make sure the depth of the liquid and the surface area
of the potato piece is approximately the same.
* I will make sure the room temperature stays approximately the same
and I will try not to vary it too much if it can be helped.
Accuracy:
* I used a ruler to measure each potato core to make sure it was the
correct length, or as near as it was possible (never more than 1 mm
out).
Preliminary Work:
The preliminary work allows you to make hypotheses and check that the
test can be done completely fairly, with reasonable measurements. I
also cut one piece of potato into mm strips, but this was very time
consuming. However this did show that the surface area of the potato
does make a difference to the results.
* I was going to do all the six different molarities with five repeats
in different beakers, however I realised this would use up a lot of
equipment and solution, so I decided to do all the five repeats in one
beaker, and multiply the amount of solution by five so I would still
have a fair test.
* I was going to use test tubes, but I realised the amount of solution
I wanted to use would not fit into one test tube, having multiplied
the amount of solution, so I used small beakers instead.
Preliminary Results:
2.34
1.19
1.44
Prediction:
Range:
Precautions
*Whilst cutting the potato, extreme care was needed to make sure it
did not harm anybody.
* I had to ensure that each time I handled the potatoes my hands were
clean and dry. This was to stop any contamination and made sure I
didn't pass on any excess water or sugar from my hands.
Apparatus:
* Distilled Water
* Measuring Cylinder
* Cutting tile
* Potato - of one type to make the experiment fair (see fair testing)
* 6 beakers
* 2 Pipettes - one for the sucrose solution, one for the distilled
water so that they do not become contaminated.
Diagram:
Diagram 1:
Diagram 2:
Molarity Table:
Molarity (M)
Water (cm3)
Ratio
(water: sucrose)
0.0
100
0.00
100:0
0.2
80.0
20.0
80:20
0.4
60.0
40.0
60:40
0.6
40.0
60.0
40:60
0.8
20.0
80.0
20:80
1.0
0.00
100
0:100
Method:
1. I took one average sized potato, checking it was hard and healthy.
3. Taking 6 beakers, I labelled each one 0.0, 0.2, 0.4, 0.6, 0.8 and
1.0.
6. I placed 5 pieces of potato into each beaker and left them for
approx 36 hrs.
7. After this time I drained out the solutions from the beakers and I
carefully placed them in order of molarity on a paper towel.
8. I dried the potato chips gently and then weighed each potato piece
and recorded the results.
Results:
Molarity (M)
(Results 1)
(Results 1)
0.0
0.79
0.77
0.80
0.73
0.74
1.35
1.34
1.36
1.26
1.27
71
74
70
73
72
0.67
0.74
0.73
0.73
0.71
1.13
1.27
1.26
1.25
1.21
68
71
72
71
70
0.2
0.81
0.73
0.72
0.68
0.69
1.19
1.19
1.12
1.26
1.15
47
63
56
72
66
0.63
0.73
0.69
0.74
0.75
1.04
1.17
1.18
1.25
1.27
66
60
65
69
69
0.4
0.74
0.77
0.75
0.68
0.74
0.87
0.79
0.86
0.86
0.90
18
23
15
26
22
0.70
0.72
0.75
0.71
0.67
1.06
1.05
1.12
1.06
0.94
51
46
51
49
41
0.6
0.69
0.68
0.67
0.78
0.72
0.70
0.68
0.65
0.69
0.74
-3
-12
0.75
0.71
0.70
0.78
0.70
0.95
1.04
1.06
0.96
1.00
27
46
51
23
30
0.8
0.68
0.74
0.64
0.73
0.67
0.66
0.68
0.58
0.61
0.56
-3
-8
-23
-16
-16
0.73
0.74
0.68
0.76
0.75
0.76
0.74
0.63
0.71
0.81
13
-7
-6
1.0
0.76
0.70
0.71
0.75
0.70
0.56
0.57
0.56
0.53
0.53
-26
-19
-21
-29
-24
0.70
0.76
0.72
0.74
0.70
0.67
0.64
0.61
0.63
0.62
-5
-16
-15
-14
-9
These values clearly support my prediction, and even though there are
some anomalous results, there is an overall negative trend across the
whole set of results, proving them accurate.
Analysis of Results:
The sucrose concentration of the solution into which the potato tissue
is placed affects to what degree it grows or shrinks. As you can see
from the graph the results show a clear negative correlation, a very
obvious inversely proportional trend. From this a conclusion can be
drawn. When the water concentration is high, the potato gains water,
as seen by the 0.0 molarity solution. When the water concentration is
low, the potato loses weight and therefore decreases in mass, as seen
in the 1.0 concentration solution. This proves my hypothesis correct.
The results were quite widely ranged, as seen on the graph, with quite
a few anomalous results, especially results no. 2. The results show
that the line of best fit should be slightly curved, to accommodate
for the 0.4 and 0.6 results. I have drawn the graph with % change,
because it is more accurate. I have used the equation shown below to
calculate the % change.
[IMAGE]% Increase = (B - A)
Evaluation:
I believe we gained sufficient enough results, shown on the graph and
the tables that conclude the experiment, and to prove my hypothesis. I
obtained a good amount of fairly accurate results, from which I was
able to make informative graphs. I believe I took enough repeat
results for the number of concentrations I was using, and I believe
the time I used was sufficient to prove that osmosis had occurred. My
final results were very reliable, due to the precautions I took to
make this a fair test. However there were some anomalous results. I
believe these were caused by some of the reasons highlighted below and
also the fact that I could not control any heat variations or the
evaporation levels of the liquid within the lab. I could have
controlled this by placing the beakers in a water bath kept at a
constant temperature and by covering the beaker in cling film to
prevent moisture escaping.
Even though there were anomalous results, and that I would have to
repeat those results more to prove completely conclusively that the
graph is completely correct, there is definitely a negative downward
trend across the graph, proving my conclusion correct. I believe that
my procedure was suitable for my experiment and I would improve it
with the previous factors mentioned above and the list of factors
mentioned below. I believe that overall my results were fairly
accurate, and a firm conclusion can be drawn from them.
v The potato cores all had different levels of moisture at the start
of the experiment, meaning that some potato cores would need less
osmosis to reach equilibrium within the same molarity solution. I
could have regulated this by using the same potato all the way through
the experiment.
v I will make sure the beaker's size is kept the same size and that
all the potato pieces are fully submerged to the same depth at the
start of the experiment.
v When the potato pieces were dried after the experiment, to remove
the surface liquid, it was not necessarily done the same with each
potato piece. The experiment could have been more exact by creating a
uniform drying method for each of the pieces.
v The experiment would have been more exact if I had found a way of
removing and measuring all the sores at the same time to reduce the
time difference between weights being measured. This could have
affected the results slightly. Otherwise it would have been better to
do each core one by one and measure them after an exact space of time.
However this is unpractical due to the probable slight variations in
time and measuring of the substances due to human error.
v Using more molar solutions would have helped to obtain more accurate
results and produced a far more accurate graph.
v I could have also varied the tissue type, for example, to use
carrot, or apple or even animal cells, to prove that osmosis occurs in
all living plant/animal cells. I could have also varied the potato's
age, to see if age affects the rate or levels of osmosis. I did try to
keep the cells the same, but this was very difficult, as I had no way
of telling their exact age. I also tried to use the cells from the
same potato, however the potato didn't have enough cells to cut enough
cores from for all the results and therefore I was forced to use two
different potatoes.
v I could have also altered the length and diameter of the cores. This
however, would only change the results due to a larger or smaller
surface area, and I would obtain the same sort of results as I did
from the chopped core in my preliminaries. I could have also diced the
potato core, like I did in my preliminaries, because that would
increase the surface area.
v The scales I was using gradually became sticky due to all the potato
cores, therefore more weight may have been added later because of the
excess water and sugar.
v The potato pieces were all cut by hand with a ruler and scalpel, so
the cuts were often not exact and often the potato cores were slightly
longer or shorter than they should have been. For the next time, I
would make some sort of template or machine to cut all the cores to
exactly the same length.
v The anomalies in the graph may have been caused by the fact that the
chips may not have been fully submerged in the solution, because the
potato cores had a tendency to float on the surface, limiting the
surface area, and therefore meaning that some of the cells were not in
the solution and were not able to carry out osmosis. I could have made
some sort of fabric sieve or cover over the pieces to make sure that
they were properly submerged.
Conclusion:
Because water molecules have a form of kinetic energy, they are always
moving around in either a gaseous, solid or liquid state, randomly
from one place to another. The greater the concentration of water
molecules in a solution, the greater the total kinetic energy, and the
higher the water potential will be. This means that as the
concentration of glucose molecules increases in a solution, the
concentration of water decreases, lessening the solution's water
potential, and decreasing a solution's ability to move between
solutions due to osmosis. Therefore as the concentration of glucose
increases in each solution, the water in that solution is less able to
move to the potato, causing water from the potato to move into the
solution, decreasing the potato's length, mass and width. An osmotic
system is set up when a semi-permeable membrane is placed between two
solutions. There are many examples in the biological world, in many
plants and animals.
Please enter your 123HelpMe Free Essay Number to read this document.