Month MAY YEAR 2016
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
JUNE
K.P.K STEEL HATTAR
CRANE LOG
Shade C crane 3 (Tapa CRANE)
May-16
DATE Fault Discription
13/5/2016 HOIST motor fault and replaced
15/5/2016 a standby motor is installed on the trolly
25/5/2016 motor fault hoist configration is shifted to standby 20HP motor and faulty
motor is removed for repairing
25/5/2016 A 40 HP repaired motor is installed with no load current of(R_15A/ Y_16A
B_15A) in the peak time shutdown
30/5/2016 HOIST Motor break problem(loose break fault) ,fault is removed
31/5/2016 HOIST Motor break problem(loose break fault) ,break is checked and
fault is recovered
crane remote broken goes out of orde , a new remote is insltalled
JUNE
K.P.K STEEL HATTAR
CRANE LOG
Shade C crane 1 (LADLE CRANE )
May-16
DATE Fault Discription
13/5/2016HOIST BRAKE MOTOR(COPLA) CONNECTION FAILURE
fault removed by re-connection
16/5/2016runway breaker tripping fault ,fault removed by re-connection
JUNE
K.P.K STEEL HATTAR
CRANE LOG
Shade C crane 2 (LADLE CRANE )
May-16
DATE Fault Discription
16/5/2016resistors ar broken due to trolly end stops
new end stops are febricated and installes also new resistors are
installed
26/5/2016Trolly motor belts(2) are changed
27/5/2016HOIST MOTOR fault motor shaft goes out of order (broken) motor is
removed for repairing
29/5/2016repaired motor is installed to the HOIST
JUNE
K.P.K STEEL HATTAR
FURNACE log
May-16
Fault Discription
1/5/2016 panel pipe leakage heat off and repaired in 15 min
8/5/2016 FEC Tripped due to spark in coil ,carbon removed from sparking spot
and heat is on withen 10min
9/5/2016 FEC is tripped due to fuse blown in FEC converter panal,fuse is changed
withen 35 min
17/5/2016Desizing of the coil due to improper coil support,desizing leads to coil
expension and the EMF effect for rapidly reversing megnetic field
water circulation in ringer pipe is also blocked
new coil is installed along with the necessery installation pakage
18/5/2016coil yoke is over heated due to bypassed water circulation system in the
repaired yoke, more insulation pakage is used between coil and yoke
19/5/2016transformer tripped due to earth fault