Professional Documents
Culture Documents
In Partial Fulfilment For The Requirement In: Researcher
In Partial Fulfilment For The Requirement In: Researcher
In Partial Fulfilment For The Requirement In: Researcher
In Partial fulfilment
For the requirement in
On-the-Job Training
Researcher:
JONATHAN R. VALLESTERO
Submitted to:
Noted By:
______________________
RAFFY UBALDO
Production Supervisor
ABSTRACT
CASE STUDY
I. Introduction
Products:
BEDDINGS CURTAINS
CUSHIONS PLACEMATS
TOWELS POUCH
TOTE BAG DECORATIVE
FABRICS
Material Sources
BILL OF MATERIALS
Part no. Part Drawing Quantity Make or Buy
Name no. per unit
1 Packaging 001 1 Buy
Materials
2 Threads 002 1 Buy
3 Fabric 003 1 Buy
4 Leather 004 1 Buy
5 Foils 005 1 Buy
6 Appliqué 006 1 Buy
Glue
7 Zipper 007 1 Buy
FLOW PROCESS CHART OF TOWEL
Symbol Description
Stamping Ink
SA-1
Fabric
Appliqué
Glue
SA-2 A-1
I-1
Thread
I-2
Box
Sealers
SA-3 A-2
Strap
7 Trimming 0 2mins. 13
sec.
8 Brushing 0 4mins. 3
sec.
9 Iron Ironing 0 1 min. 53
sec.
10 Inspection of 0 1 min. 20
the product sec.
11 Automated Packing 48 seconds 34 seconds
strapping
machine
Symbol Description
The worker will get the fabric from the
stock of fabrics.
The same worker will stamp the fabric.
Activity Relationship
Code Closeness Line Code Numerical
Weights
1 2 3 4 5 6
A Absolutely
Necessary 4
E Especially
necessary 3
I Important 2
O Ordinary 1
U Unimportant 0
X Undesirable -1
Grid Diagram
6 4 3
5 2 1
Nodal representation
CENTER OF GRAVITY
Quezon
(14.68’ N, 121.
04’ E)
Marikina
(14.65’N,
121.10’ E)
Binondo (14.60’
N, 121.08’ E)
Manila (14.61’ N,
121.02’ E)
Pasig (14.57’
N, 121.09’ E)
Propose location
NAIA III (14.51’ N, (14.52’ N, 121.03’ E)
121.02’ E)
Alabang (14.42’ N,
121.04’ E)
COMPUTATION:
X- AXIS = Y- AXIS=
(10)(121.0851)+(8)(120.9750)+(40)(12 (10)(14.5764)+(8)(14.6091)+(40)(14.6
1.1029)+(70)(121.02230)+(150)(121.0 507)+(70)(14.6091)+(150)(14.6760)+(
437)+(300)(121.0385)+(400)(121.016 300)(14.4184)+(400)(14.5123)
5)
30+40+70+150+300+400 30+40+70+150+300+400
EXISTING LAYOUT
1. Illumination
STORAGE
Time Data Data Data Average
1 2 3
9:00 131 136 140 135.67
3:00 114 119 116 116.33
7:00 150 139 154 147.67
The three tables’ shows the data gathered for the illumination
in the stamping department with the time frame for gathering
the data is 9:00, 3:00 and 7:00. The data gathered is expressed
in Lux. The highest data is in the QC section considering that it
is the QCsection which requires a greater illumination and
there is also a secondary source of light coming from the
window. The lowest data is in the storage that doesn’t have a
fluorescent above it and it is place in corners. The data
gathered shows that the working area has met the standards
recommended for illumination levels.
2. Sound Intensity
Time Data Data Data Average Time Data Data Data Average
1 2 3 1 2 3
9:00 67 67 63 65.67 9:00 67 62 66 65
3:00 76 73 75 74.67 3:00 75 73 75 74.33
7:00 74 72 75 73.67 7:00 72 72 74 72.67
STORAGE
Time Data Data Data Average
1 2 3
9:00 63 61 65 63
3:00 75 76 72 74.33
7:00 73 75 75 74.33
The data gathered for the sound intensity is in terms of
decibels. Stamping area has the highest sound intensity
because this area has the most number of workers and the
lowest is in the QC section because there is no much sound
created as they just check for defects and this is also the place
where they receive issues and no machine is being used at that
time. In the afternoon, the sound intensity went up because
they play the radio inside the company.
3. Temperature
Time Data Data Data Average Time Data Data Data Average
1 2 3 1 2 3
9:00 24.7 24.3 24.2 24.4 9:00 23.3 22.7 23.2 23.07
3:00 21.3 21.3 20.9 21.17 3:00 20.2 20.4 20.2 20.27
7:00 20.4 20.5 19.9 20.27 7:00 19.4 19.7 19.6 19.57
STORAGE
Time Data Data Data Average
1 2 3
9:00 24.4 23.9 23.8 24.03
3:00 21.7 21.2 21.4 21.43
7:00 20.1 20.1 20.4 20.2
The temperature gathered is in terms of degrees Celsius. The
temperature is not much a problem in the workplace as it is in
Baguio and the worker feels more comfortable because they will
not sweat and it will not affect their performance. The highest
data is in the stamping area because the workplace is more
packed with workers and the light is not that high. The lowest
data gathered is in the QC section as there is a window that
provides cooler air coming from outside.
General Hazards
ALTERNATIVE LAYOUT 1
ALTERNATIVE 2
ADVANTAGES OF THE NEW FACILITY DESIGN AND
LOCATION
V. Recommendations
After conducting the case study the researchers come up with
the following recommendations:
REFERENCES:
Tompkins, James A., Facilities Planning
https://www.osha.gov/
https://www.osha.gov/SLTC/ergonomics/
https://ehs.unc.edu/workplace-safety/ergonomics/