Technical features
Medium: Mounting: Ambient/media temperature: Materials:
Air, neutral gases and liquids G1/4 others on request Ambient: Body in contact with media:
Operation: Orifice: -15 ... +50 °C (+5 ... +122°F) Stainless steel, brass, PA
Direct acting 2-way and 3-way 2/2: 0,5 .... 8 mm (0.02 ... 0.31”) Media: Seal in contact with media: NBR,
valves, normally closed and 3/2: 0,8 .... 3 mm (0.02 ... 0.12”) -15 ... +140 °C (+5 ... +284°F) FPM, EDPM
normally opened, latching Port size: Air supply must be dry enough
Operating pressure: G1/4, G1/8, M5, CNOMO to avoid ice formation at
0 ... 100 bar (0 ... 1450 psi) Response time: temperatures below +2 °C (+35°F).
Flow kv factor: 10 ... 15 ms
0,15 ... 14 (Cv: 0.01 ... 1) Response time measured
according to ISO 12238
Our policy is one of continued research and development. We therefore reserve the right to amend, without 01/17
notice, the specifications given in this document. (2015 - 5027c) © 2015 Fluid Automation Systems s.a. en 5.2.080.1
FAS 32 mm BACOSOL
Direct acting solenoid valve
1 3 1 3
2 2 10 12 2 10
1 3 1 3
Accessories
Electrical connector
DIN EN 175301-803, Form A
N040.1001
Our policy is one of continued research and development. We therefore reserve the right to amend, without
en 5.2.080.2 notice, the specifications given in this document. (2015 - 5027c) © 2015 Fluid Automation Systems s.a. 01/17
FAS 32 mm BACOSOL
Direct acting solenoid valve
G1/4
ø 20
ø 20
1 2
25
12,5
7
1 2
24
32
24
32
7
24 24
32
45 1 45
32 G1/8 G1/8
7,5
7,5
3
63
62
3
2 1
15
14
ø 4,3
ø 9,5 M4
0,5
4,5
1
1 Manual override
Our policy is one of continued research and development. We therefore reserve the right to amend, without
01/17 notice, the specifications given in this document. (2015 - 5027c) © 2015 Fluid Automation Systems s.a. en 5.2.080.3
FAS 32 mm BACOSOL
Direct acting solenoid valve
(available for 3/2 NO valves) (available for 2/2 NC & 3/2 NC valves) Projection/First angle
13 24
7 15
3,5 7,5
16
3
2 1
24
30
4
78
31,5 30
0,5
45 ø5
5
,7
11
R
45
3
32
2 1
16
G1/8
1
88
7,5
41
8
1 4,3
8,5
3
20
21
G 1/8
M4
16
1 Manual override
50
32
19
18 15
18,5
25
Warning
These products are intended for use in air, neutral gas and liquid The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under »Technical features«. safeguards to prevent personal injury or damage to equipment in the
event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems, or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult IMI FAS. adequately provided.
Our policy is one of continued research and development. We therefore reserve the right to amend, without
en 5.2.080.4 notice, the specifications given in this document. (2015 - 5027c) © 2015 Fluid Automation Systems s.a. 01/17
Diese Produkte sind ausschließlich mit industrieller Druckluft-, neu- systemen verwendete Komponenten auf verschiedene Arten versagen.
tralen Gas und Fluid-Systemen zu verwenden. Sie sind dort einzu- Systemauslegern wird dringend empfohlen, die Störungsarten aller