PowerPoint Presentation PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

INTRODUCTION • The name comes from Latin hospes (host).

007
023
CLASSIFICATION OF A HOSPITAL • A hospital, in the modern sense of the word, 028
(a) Depending upon the nature of the health facilities- is an institution for health care providing 029
1.PRIMARY HEALTH CARE-
• It is a first level of care. patient treatment by specialized staff and
• Caters population of about 10,000. equipment, and often, but not always
2.SECONDARY HEALTH CARE- providing for longer-term patient stays.
• Special care is provided following referral from a primary health
professional. • Its historical meaning, until relatively recent
• These are District level hospitals. times, was "a place of hospitality".
3.TERTIARY HEALTH CARE-
• Highly specialized consultative care to the patients referred from
secondary level facilities.

b)Depending upon the no. of beds

CATEGORIES NO. OF BEDS


A 25-50

B 51-100

C 101-300

D 301-500

E 501-750

FORM OF HOSPITALS
• The form of a hospital is strongly influenced by
the choice of access and circulation routes. ZONING
• It is therefore necessary to decide earlier on
whether to choose a spine form with branching Location of the building should be convenient
sections (individual dept.)or whether circulation to the people it serve.i.e the public zone
will be radially outwards from a central core. should be in front. Effective zoning is required
• Consideration will be given to future expansions. :
• The vertical arrangement within a hospital • public zone ,clinical zone and staff zone.
should be designed so that the functional areas : • privacy and confidentiality are important
care , treatment ,supply and disposal, access for • security and supervision in the premises
bedridden patients, service yard underground will be necessary .
garage ,stores ,administration , medical services • emergency should have separate entrance.
–can be connected and accessed most Mortuary should be linked with service
efficiently. road.
• Land must not be contaminated
PRINCIPLES OF A HOSPITAL DESIGN 007
023
 TOTAL AREA: 028
029
• The total area to be provided for a hospital
shall depend on availability of land, however an
area of 1 hectare for every 25 beds is
recommended.
 SITE PLANNING:
• sensitive areas like wards, consulting &
treatment rooms and operation theaters are
placed away from the outdoor sources of
noise
 ORIENTATION
• The most suitable orientation for treatment and
operating rooms is between N-W and N-E.
• For nursing wards façades south to south-east is
favorable ; pleasant morning sun , minimal heat
built up little requirement for sun shading , mild
in the evenings .
• East and west facing rooms have comparatively
deeper sun penetration , through less winter sun
.
 LANDSCAPING
• landscape elements such as open areas,
horticulture to increase the comfort conditions
inside the building and also in the surrounding
environment should be kept in view.
 STRUCTURAL GRID
• The constructional grid must provide a precise
guide as well as allowing for differentiation of
areas for the main functions, support functions
and vehicular traffic.
• The variation operations centers can be planned
most appropriately with a column grid spacing of
7.2m or 7.8m smaller construction grids are
problematic because large rooms (eg.operating
theatres) which must be free from internal
columns are more difficult to accommodate.
FORTIS HEART & MULTI-SPECIALITY HOSPITAL,MOHALI 007
023
028
 CLIENT : FORTIS HEALTH CARE LIMITED 029
(FHL),C/O,Ranbaxy Laboratories Limited.
 DESIGN TEAM : Kaplan MC Laughlin Diaz, California.
 LEAD ARCHITECT : Achal Kataria & Associates, New Delhi.
 TOTAL PLOT AREA : 8.22 acres.
 TOTAL BUILT –UP AREA : 40000sq. M
 HEIGHT OF BUILDING : 30 m (including glass tower).
 YEAR OF COMPLETION : 2001.
 DURATION OF CONSTRUCTION : A record 18 months.
 COST OF PROJECT : 155 crores.

LOCATION :
 Located in sector 62, Phase VIII, S.A.S. Nagar, Mohali (Distt. Ropar), SITE ANALYSIS :
Punjab, India – Just 7 kms. from Chandigarh.  The linear proportions of the site 3:1 have brought out the linear plan of
 Very near to the bus-stand – Thus comfortable to the patients coming from the hospital building, the two entrances being on the longer side.
out of city.  Spread over 8.22 acres.
 It is 14kms from the airport, 9 kms from bus stand (sec 17) and 12 kms.  Rectangular plot : 344m x 110m
from the railway station. x

ORIENTATION :
CHANDIGARH

BLDG.
PSEB

x x x
FROM

TO AIR
TERMINAL  The building faces north-east, the most favourable orientation.

TO BUS STAND

Care has been taken to place the curved surface of the building out to that
MARKET
&MULTI SPECIALITY

direction to get the maximum exposure to glare-free light. CURVED


FORTIS HEART

HOSP

FLOOR SPACE DISTRIBUTION SURFACE

LOCATION PLAN 15%


(NTS) 7%
6% 55%
17%
SURROUNDINGS :
 The approach to the site is from a 24m wide road running all around
the site.
 It has PSEB building on one side & the Punjab Urban Planning & IN PATIENT
Development Building opposite to it and a proposed market behind it.
DIAGNOSTIC AND TREATMENT
SIGNIFICANT FEATURES :
OPD AND EMERGENCY
 With site area of (334m x 110m)sq. m.= 36740 sq. m. and permissible
 ground coverage of 30%, the complex has been divided into 4 blocks – ADMINISTRATIVE
A,B,C & D.
SERVICES
ZONING , CIRCULATION & PARKING
LANDSCAPING:
 Divided into five zones Landscaping has been paid special attention here at FORTIS, Mohali,
 The first:public area comprising entry/exit and parking using it as an element of beauty & at the same time to rejuvenate the
 The second: The Rehabilitation building which has less spirit of the patients.
traffic. A stepped landscaped courtyard between the two buildings of the
 The third: The Main Hospital Building approached by hospital enabling the patients to look down on the greenery, not making
patients, their visitors, the staff and doctors. them feel sick seems to be on the pattern of Mughal gardens.
 The Service dock at the back & basement parking form the
Shapes like circular & other curvilinear forms :
fourth zone.
Thus providing harmony & unity at site level.
 Last the beautiful landscaping spread all over the site STEPPED
Road edges marked with flowers and specific LANDSCAPED
PARKING : landscaped areas earmarked by flower pots. COURTYARD
 Paid public parking on the immediate left ( 120 cars & 50 scooters ) : P1
 Parking for ambulance right next to the emergency entrance/exit: P2 N ZONING (BUILDING LEVEL) :
 Separate staff parkings: P3 The main hospital building
BLOCK-A BLOCK-B
 Basement car park for doctors, high officials etc : P4 has been divided into 4
blocks:
CIRCULATION : BLOCK A: : Emergency
area, with separate gate and
 All the segregations follow a defined & specified path leading
entrance.
to their respective destinations.. BLOCK-C BLOCK-D BLOCK B : Inpatient
Administration with traffic
restricted to patients
admitted & their visitors
BLOCK C Diagnostics and

P2 Labs
BLOCK D : OPD &

P1 Rehabilitation centre, closest


to Parking as OPD has
maximum public traffic..
There are 4 ENTRANCES
to the main hospital building
OPD, IPD, Emergency,
Services

P3 007
023
028
029
COVERED OUTSOOR KISOKS
TWO WHEELER
LANDSCAPED COURTYARD PATHWAYS FROM PARKING
OPD TO IPD N

OXYGEN PLANT CANCER INST. PORCH

OPD TO EMERGENCY
COFFEE SHOP
FOUR WHEELER PARKING
CIRCULATION :
HORIZONTAL CIRCULATION : DOUBLY LOADED
MAIN SPINAL
• Main spinal cord of the hospital : 2.45m wide. CORRIDOR
CORRIDOR

• It bifurcates to form a doubly loaded curved corridor COURTYARD


(2.45m wide) in the blocks A & B.
SINGELY LOADED
• Another 2.45m wide singly loaded corridor runs throughout CORRIDOR
ACCESS CORRIDORS
the length of blocks C& D along a landscaped courtyard.
• Basically the inter-departmental circulation is being
governed by 2.45m wide corridors & the intra-
SCRUB AREA
departmental by 1.8m wide corridors. FOR IVF OT,S
• Swinging doors have been placed at regular intervals in IN THE
the corridors to provide a defined path to user zones and at ACCESS
the same time to provide privacy to the various SINGLY LOADED CORRIDOR CURVED CORRIDOR CORRIDORS
departments.
VERTICAL CIRCULATION:
It can be divided into 3 components :
Staircases, Lifts,Ramps
• STAIRCASES : LIFTS LOBBY
Fire-escape - 4
Public -3
Rehab -1
• LIFTS :
Public - 6
Bed-lifts – 2
Service - 4 FIRE ESCAPE STAIRCASE
Rehab - 1 PUBLIC STAIRCASE
• RAMP - 1 LIFTS CORRIDOR OUTSIDE
DUMBWAITERS CONSULTANT ROOM
• One CAGE-LIFT in kitchen for the transportation of
material from basement stores to kitchen at the GF,
two DUMB WAITER lifts connected from CSSD to
Day care OT and Cardiac OT at 1st and 2nd floor
respectively.
RAMP TO BASEMENT • Each block has its own staircase.
• Most of the staircases are on external walls having
natural light and ventilation.
007
• There is a ramp ( 1:7 slope, 6m wide) going down to 023
the service dock for loading / unloading of material 028
from trucks & the staff parking in basement. 029
BASEMENT PLAN:
6
7
8 9 10
11
12
PARKING
5 13

4 14

3 15

2 PARKING LADIES
GENTS
TOI.
TOI. 16

1
17

UP

Block A & B :
LVL -3.15M 18

LVL -3.15M
A

 Lvl. = - 3.15m B
SCOOTER PARKING

A
C
UP
DN
MORTUARY STAFF PARKING
 It provides staff parking for about 85 cars & 75 WASTE
LIFT LOBBY
WASTE WASTE UP
(FOR BEDS)
DISPOSAL DISPOSAL DISPOSAL
D

LOBBY SCOOTER PARKING SUMP

scooters. E

EMERGENCY
ENTRY TO BASEMENT
LIFT LOBBY-3 PRAYER
(FOR SERVICE) RM.
N
 Block A also houses the waste disposal storage.
PARKING 12.1 13.1 14.1 15.1 16.1 17.1 18.1

CORRIDOR
0.8 1.8 2.8 3.8 4.8 5.8

2450 WIDE
OFF.
F
MORTURY
(RECEIVING)

D.G ENGG.
LVL -3.15M
 It also has public toilets and a lift lobby. LOADING UNLOADING

LVL(-3.45 FFL)
C

H
STORE

2450 WIDE
LAUNDRY CSSD SET
2450 WIDE
DEPT UP

A'
CHEMICAL STORE 2450 WIDE
CORRIDOR LAUNDRY FOR LAUNDRY
SUMP
CORRIDOR
LAUNDRY CORRIDOR

Block B also has a mortuary and prayer room.


FHC-6
CSSD CLEAN


STORE UP RECEIVING LAUNDRY WASHING STERILE STAFF STAFF
CSSD

ELE/TEL/DATA
AREA

ELE/TEL/DATA
PUMP
ENGG OFF.
STAFF SECURITY
/DRYING JAN CH. STAFF CH.

ELE/TEL/DATA
RM. OFFICE
ELECTRIC LAUNDRY AREA
+ 4.65 M FFL

0070
TOI. TOI.
ENTRANCE FOR RECEIVING BAY PANEL DISPATCH WASH RM. RM.
DEPT.
RM.
KITCHEN GOODS RAMP DN
CHIEF
OFF.
AHU SUPERVISOR RECEIVING ENGG.
J J
UTILITY OFFICE MEDICAL
LAUNDRY
STORE LAUNDRY CSSD CSSD DW DW
ELECTRIC
RM RECEIVING RECP. TROLLEY CSSD
CLEAN WASH SUPERVISOR DIESEL GENERATOR PANEL RM.
RECORD ( P&S)
LADIES
CSSD
LVL -3.15M
LAUNDRY AREA DESPATCH SET PUBLIC HEALTH SERVICES
RM. HOUSE
KEEPING
CH.
BLDG
2450 WIDE STORE
LVL -3.15M
2450 WIDE ACCOMODATION
CORRIDOR CORRIDOR
K K
CH ENGG WORKSHOP
DRY TROLLEY PHARMACY CABIN
STORE PARK/WASH INCHARGE
STORE LT PANEL PUMP
STORE PANEL MECHANICAL
BIO MEDICAL RM. RM.
KITCHEN CONFEC. RM.
DINING PHARMACY
ENGG UPS SERVICES PUMP
MATERIAL TESTING
LAB
COLD
HT PANEL PANEL
STORAGE SUMP
RM.
DEEP CAGE
BAKERY
STORE
WORKING CARPENTRY TRANSFORMER
RM. RM.
TRANSFORMER TRANSFORMER
RM. RM.
RM.
RM.
AREA
FREEZER LIFT
L L

BIO MEDICAL 27 28 29 30 31 32 33 34 35 36
19 20 26

ENGG
21 22 23 24 25
SUMP

SERVICES

STERILE
LAUNDRY
COLLECTION
WINDOW
PARKING FOR STAFF IN THE 7
7
8 9 10
11
PARKING
12
6

BASEMENT 5
13

4 14

3 15
GENTS
2
PARKING LADIES LADIES TOI.
TOI. TOI. 16

1
17

UP
LVL-3.15M LVL-3.15M 18

SCOOTER PARKING
C
UP
DN
LIFT LOBBY
WASTE WASTE WASTE
(FOR BEDS) LIFT LOBBY
DISPOSAL DISPOSAL DISPOSAL UP
D (FOR BEDS)

E
LOBBY SCOOTER PARKING SUMP

EMERGENCY LIFT LOBBY-3 PRAYER

0.8 1.8 2.8


ENTRY TO BASEMENT

3.8
PARKING
4.8 5.8
(FOR SERVICE) RM.
12.1
BLOCK B13.1 14.1 15.1 16.1 17.1 18.1
F
CORRIDOR
2450 WIDE

OFF.
(RECEIVING) MORTURY
BLOCK A
LOADING UNLOADING STORE
LVL(-3.45 FFL)

STORE
007
+ 4.65 M FFL ENTRANCE FOR
KITCHEN GOODS
RECEIVING BAY

RAMP DN
BLOCK-A 023
BLOCK-B 028
BASEMENT 029
Block C -
It has main Kitchen, a Pharmacy department, Medical
record room, Laundry, CSSD, Bio-medical engineering workshop,
carpentry unit, stores, EDP (Electronic Data Processing unit), UPS
room, Electricity panel room, diesel generator sets room, janitor,
toilets pump room. CSSD
DINING FOR STAFF MEDICAL RECORD
ROOM
LAUNDRY CSSD
C

H
LVL(-3.45 FFL) 2450 WIDE CHEMICAL STORE
CORRIDOR LAUNDRY FOR LAUNDRY
SUMP
LAUNDRY
FHC-6
CSSD CLEAN
STORE UP RECEIVING LAUNDRY WASHING
STERILE STAFF STAFF
CSSD AREA PUMP

ELE/TEL/DATA
JAN CH. STAFF STAFF CH.

ELE/TEL/DATA
/DRYING RM.
ELECTRIC LAUNDRY AREA
+ 4.65 M FFL

0070
TOI. TOI.
ENTRANCE FOR RECEIVING BAY PANEL DISPATCH WASH RM. RM.
RM.
KITCHEN GOODS
J
RAMP DN AHU SUPERVISOR RECEIVING LAUNDRY
UTILITY LAUNDRY CSSD
RM
OFFICE MEDICAL STORE LAUNDRY
RECP.
CSSD
TROLLEY CSSD
DW DW

RECEIVING CLEAN WASH SUPERVISOR


DIESEL GENERATOR
RECORD ( P&S)
LADIES
CSSD
AREA SET
BLOCK C RM.
2450 WIDE
LAUNDRY
HOUSE
KEEPING
CH.
LVL-3.15M
2450 WIDE
DESPATCH

D.G
K
CORRIDOR CORRIDOR
CAGE LIFT
DRY
STORE
TROLLEY
PARK/WASH
PHARMACY
INCHARGE
CH ENGG
STORE
WORKSHOP
CABIN
LT PANEL
SET
STORE PANEL
BIO MEDICAL RM.
RM.
KITCHEN COLD
CONFEC.
DINING PHARMACY
ENGG UPS
CARPENTRY HT PANEL TRANSFORMER TRANSFORMER
STORAGE SUMP
RM.
DEEP CAGE
BAKERY
STORE
WORKING
AREA
TRANSFORMER
RM. RM. RM. RM.
KITCHEN STORAGE
L
FREEZER LIFT
TRANSFORMER
RMS.
Kitchen storage & dining for staff BIO MEDICAL
19 20 21 22 23 24 25 26 27 28
ENGG. 29

 It consists of mainly storage areas, has a receiving bay, ENGG DEPT UP

a bakery, a confectionery, a cold and deep freezer, an H


2450 WIDE 2450 WIDE
area for parking and washing trolleys and a special CORRIDOR CORRIDOR

LT PANELROOM
ELE/TEL/DATA
ENGG OFF.
SECURITY

cage lift OFFICE

CHIEF
DEPT.
OFF.
ENGG.

Laundry, CSSD & Medical Records. ELECTRIC


J

 Laundry placed next to the CSSD for convenience in PANEL RM.


LVL-3.15M PUBLIC HEALTH SERVICES
BLDG

sterilizing clean clothes and linen. ACCOMODATION STORE

 The whole area is very efficiently planned for ease of


K

PUMP
receiving, washing & drying, ironing with special clean MECHANICAL RM.
SERVICES MATERIAL TESTING
PUMP LAB
areas & dispatch. PANEL
RM.
RM.
L

PUMP ROOM
Block D : 29
SUMP
30 31 32 33 34 35 36

• It basically consists of staff rooms with toilets, 2 lift SERVICES


lobbies, building automation units, panel rooms, HVAC BLOCK D
services,
•Public Health services, store and some space for future BLOCK-C
expansion. BLOCK-D
BASEMENT`
Ground floor plan IPD WAITING
AREA
OPD WAITING AREA

6
7 ENTRY 8 9 10
11
12

5 13

4 14

3 INPATIENT ADMN. 15

2
TOILET
16
ENT FOR EMERGENCY
OFFICE OFFICE OPD RECEPTION
1
OBSERVATION BEDS BUSINESS OFFICE INPATIENT ENTRY
OBSERVATION BEDSCARDIAC PATIENTS STAFF EMER. OFFICE 17

PATIENTS OBSERVATION BEDS


CARDIAC PATIENTS LOUNGE EXIT DN. UP.
UP CENTER OFFICE COUNTER
TROLLEY TOI. WAITING
WHEEL OBSERVATION BEDSGENERAL PATIENTS BILING/CASH/ ENT TO INPATIENT 18
CHAIR TRAUMA PATIENTS HOSPITAL LOBBY
VESTIBULE 2450 WIDE
REGESTRATION TOI.
POLICE CORRIDOR RECEPTION PHARMACY
LADIES GENTS
POST WAITING

ELE/TEL/DATA

ELE/TEL/DATA
2450 WIDE TOI. TOI.

1200 WIDE CORRIDOR


MSKP STORE SLUICE PRAYER +750M FFL
LOBBY CORRIDOR
LVL+0.75M ENT LOBBY
A GENTS RM.
PANTRY
TOI. DARK STORE PACE
ROOM
MAKER
DU LVL+0.75M
AHU
B
LADIES X-RAY PLASTER
TOI. STAFF EMERGENCY ROOM
ULTRASOUND ECG ROOM
TOI. INCHARGE
ROOM
CARDIALOGIST INPATIENT LOBBY
A
C
UP

RECEPTION
DN. WAITING MSKP
RECEPTION 2450 WIDE 2450 WIDE BOTTLE COLD STORE STAFF INCHARGE
CORRIDOR CORRIDOR WASH STORE RM. TOI.
LIFT LOBBY VESTIBULE
SPOT DR'S UP
(FOR BEDS) DN.
CONS. STER. CH. RM. 1800 WIDE FLORIST WAITING
OFFICE TRIAGE STORE CH.STAFF
0 06 5A 0 06 4A
D INSTR. CORRIDOR
RM. PROCEDURE OPERATION PREP OT CLASS-II TOI. TOI. DONER
LADIES 0 06 5B 0 06 4B
GENTS
CONS. RM. RM.
RM.
BLOOD
MOVEMENT
BLEEDING BLOOD
MOVEMENT
TOI. 0 0 6 5C 0 0 6 4C TOI. BANK BOOK CAFETERIA PANTRY
NURSE'S MEDICAL
TOI. RM. SCRUB
LAB COLLECTION EXAMIN.
0 0 6 5D 0 0 6 4D STORE
CH. RM.
E
STAFF

EMERGENCY LIFT LOBBY-3


REST RM.
BLOOD BANK
(FOR SERVICE) CH.CH.

CH.
CH.CH. 12.1 13.1 14.1 15.1 16.1 17.1 18.1
N

CORRIDOR
0.8 1.8 2.8 3.8 4.8 5.8

2450 WIDE
F
NURSE'S
LOADING UNLOADING TOI.
RESIDENT
REST RM. REST RM.

BELOW CH. CONS'S LANDSCAPE COURTYARD DN. UP


C
CH. REST RM.
TOI.
H H

LVL+0.75M
2450 WIDE
A'
2450 WIDE CUT OUT ABOVE
CORRIDOR CORRIDOR

OPD ENTRY
FHC-6

STORE
FHC-7
CH. CH.
LVL+0.75M
UP WAITING FOR

ELE/TEL/DATA
SAMPLE RECEIVING WAITING FOR CH. TOI. TOI. WAITING FOR WAITING FOR
ELE/TEL/DATA

+ 4.65 M FFL DN. HEAMATOLOGY


& SORTING
NUCLEAR MEDI.
MRI& CT SCAN CH. CH.
X-RAY ULTRASOUND OPD LOBBY
RECEPTION
CH. CH. RECEPTION AHU
J RECEPTION J

DISH WASH AHU CONS DW DW REGISTRATION

CONSOLE
COMMON
ROOM PROCEDURE GAMMA MRI US US PROCEDURE BILING

CORRIDOR
X-RAY SPECIAL

1800 WIDE
KITCHEN RM. CT X-RAY RM. CASHERING VESTIBULE VESTIBULE

SCAN
0141G 0142D 0142E

CHAPATI SEC. PROC ROOM TOI. TOI.


TROLLEY
ROOM
SCAN
0141F 0142C
COLD DOSE 2450 WIDE
DR'S BACK GENTS WH CHAIR
TANDOOR
SP COOKING
AHU FOR STORE
COMMON
2450 WIDE
ADMN. EQUIP. CORRIDOR LIFT LOBBY FIRE
LADIES
0141C 0142B
WAITING
AREA
BIO-CHEM IMMUNOLOGY CORRIDOR
CU DU DUTY MANAGER'S OFFICE COMMAMD TOI. OFFICE
LAB
FOOD PICK UP BY TROLLEY

MAIN COOKING
ORGAN
CONSOLE DECON ROOM EQUIP. TOI. CH. TOI. TOI. TOI.
0141D
0142A
RECP.
RM.
0141E
K
TISSUE ROOM K
AREA
DIETICIAN CONS. ULTRASOUND 2450 WIDE
MAIN COOKING
AREA
RM.
HISTROLOGY
CHEM
CLINIC
WASH /
STER
ROOM FUTURE
GAMMA SCAN
PHARM. LAB FUTURE LVL+0.75M PROCEDURE
CORRIDOR ALL PARTITION
IN DRY WALL
REHABILATION THER

JUICE&SALAD
STORE TOI. EXPANSION TOI.
BULK COOKING
2450 WIDE INJEC THERAPY COUNSEL COUNSEL THER
AREA STORE 1500 WIDE CORRIDOR EXAM EXAM EXAM EXAM RM. EXAM
CORRIDOR CH.
PREP THERAPY
AREA POT WASH
OFFICE NIGHT COMMON CH. OFFICE COMMON CH.
0071G
CYTOPATHOLOGY CONS. CONS. MICRO- PANTRY TOI.
PHYSICIST NUCLEAR CU DU DUTY PANTRY DARK EXAM.
EXAM.
CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM.
GYMNASIUM

RM. RM.
PATHOLOGIST
RM. CH. IMIGING CONS. WAX BOX TH.
HYDRO 0143
PREP
AREA BIO TOI.
&SECY
TOI. MEDI. TECH. CH.
RM.
ROOM
TOI. THERAPY
L L

KITCHEN LAB
REHARB
SECTION AA’ 19 20 21 22 23

MAIN HOSPITAL BUILDING


24 25 26 27 28 29 30

OPD CONSULT
31 32

MEDICAL CENTER
33 34 35 36

LVL+16.35M

OFFICE OFFICE OFFICE SECY OFFICE GENTS LIBRARY


BI-CARBONATE
DIALYSIS
PERITONIAL
DIALYSIS
FUTURE
WAITING GENTS LADIES
TOILET
DOUBLE TOI. DOUBLE DOUBLE TOI. DOUBLE THIRD FLOOR DOUBLE TOI. DOUBLE
AHU TOI. CINDER
LIBRARIAN EXPAN. TOI. TOI.
CINDER
ELE/TEL/
DATA ROOM CINDER
ROOM ROOM CINDER
ROOM DOUBLE TOI. DOUBLE ROOM CINDER
ROOM
FILLING FILLING FILLING FILLING ROOM CINDER ROOM FILLING
FILLING
LVL +12.45M
CH. CH.
RM. RM.
CATH LAB CONF. DR'S STAFF'S ICU WARDS
STORE RM. LOUNGE AHU CH. RM. CORRIDOR ELE/TEL/
DATA
SLUICE PANTRY ISOLATION SECOND FLOOR
LVL +8.55M
STAFF'S WAITING FOR CLEAN SUPPLY STAFF'S WARDS
AHU LOUNGE CORRIDOR TOI. NON-INVASIVE SORTING LOUNGE
FUTURE
EXPAN.
WAITING
VISITOR'S
TOI. WHEEL
CHAIR
ELE/TEL/
DATA CORRIDOR
DOUBLE DOUBLE DOUBLE DOUBLE
DOUBLE
FIRST FLOOR
DOUBLE
DOUBLE DOUBLE DOUBLE
CARDIAC LAB ROOM ROOM ROOM ROOM ROOM ROOM ROOM
ROOM ROOM
LVL +4.65M

OPD LOBBY WAITING FOR CH. TOI. TOI. CH. WAITING FOR CH. SAMPLE RECEIVING ELE/TEL/ STORE INSTR. OPERATION GRD. FLOOR TRIAGE
AHU RECEPTION WAITING FOR HEAMATOLOGY DATA
CORRIDOR TOI. TOI. CH.STAFF OT CORRIDOR
CONSULT. OFF.
ULTRASOUND X-RAY MRI & CT SCAN NUCLEAR MEDI.
& SORTING CLASS-II PREP RM. PROCEDURE RM. RM.
RM.
LVL +0.75M

PUBLIC STAFF STAFF LVL ±0


ENGG SECURITY STAFF PUMP STAFF STERILE CSSD CLEAN CSSD LAUNDRY
HEALTH
OFF.
DEPT.
OFFICE CH. TOI. RM. TOI.
CH. JAN LAUNDRY WASHING ELECTRIC
PANEL
ELE/TEL/
DATA CORRIDOR
WASTE
DISPOSAL
WASTE
DISPOSAL
WASTE
DISPOSAL BASEMENT PARKING
RM. AREA AREA WASH /DRYING DISPATCH
SERVICES RM. RM.
LVL -3.15M

WAITING
AREA IN
CONSULTA 007
NTS ROOM 023
028
OPD CLINIC WITH OPD CLINIC 029
GROUND FLOOR lEVEL : Emergency
sheltered entrance to protect patients from the 6
7 ENTRY
weather while unloading. 5

Lvl. = + 0.75m The ambulance entrance should be large 3


4

enough to admit one or more ambulances


•Block A :
2
TOILET
ENT FOR EMERGENCY
negotiating with stretchers. it should be well 1
OBSERVATION BEDS
STAFF EMER.
marked with proper lighting and signs and

OBSERVATION BEDS CARDIAC PATIENTS
This block is basically the emergency area. should be easily visible and accessible from the TROLLEY
WHEEL
PATIENTS
TOI.
OBSERVATION BEDS CARDIAC PATIENTS
OBSERVATION BEDS GENERAL PATIENTS
LOUNGE EXIT

 It has its own reception area, public toilets, street LVL+0.75


POLICE
VESTIBULE
CHAIR TRAUMA PATIENTS
2450 WIDE
CORRIDOR

The department should be close to WAITING TOI.

ELE/TEL/DATA
observation rooms for cardiac & trauma patients, POST
2450 WIDE

1200 WIDE CORRIDOR


MSKPSTORE SLUICE
A GENTS LOBBY CORRIDOR
admission, TOI. DARK STORE
PANTRY
PACE
DU
facilities like X ray, ultrasound, a small O.T. and medical records B
LADIES X-RAY
ROOM

ULTRASOUND
ECG
PLASTER MAKER AHU
TOI. STAFF EMERGENCY ROOM ROOM ROOM
CARDIALOGIST
change rooms. cashier’s booth. C
UP
DN. RECEPTION
TOI. INCHARGE
2450 WIDE 2450 WIDE

 A special trolley bay & wheel chair parking laboratory services including the blood bank CORRIDOR
SPOT
CORRIDOR
DR'S
LIFT LOBBY
(FOR BEDS)
Proximity to elevators is also important in order CONS. STER. CH. RM.
D OFFICE
RM. TRIAGE INSTR. STORE CH.STAFF

in the vestibule for immediate action. to proceed to surgery without loss of time. CONS. RM.
PROCEDURE
RM.
OPERATION
RM.
PREP OT CLASS-II TOI. TOI.

• Block B :
NURSE'S
TOI. RM. SCRUB CH. RM.
E

EMERGENCY
 It has the INPATIENT DEPARTMENT with the necessary facilities. 0.8 1.8 2.8 3.8 4.8 5.8

 It consists of a reception area, a billing/registration counter, a waiting area, a business


centre, some offices, a pharmacy & public toilets and a blood bank. LOADING UNLOADING
BELOW
7
8 9 10
11 BLOCK A

12

In addition to all this, the block consists of ENTRY 13


STORE
+ 4.65 M FFL
IPD ADMN.
14
various facilities like a cafeteria (Café 15

Ritazza), a florist, book store, bank & a TOILET


16

prayer room. OFFICE OFFICE


OFFICE
STAFF EMER. BUSINESS OFFICE 17
LOUNGE EXIT DN. UP.
UP
WAITING
CENTER
BILLING/CASH/
OFFICE
IPD ENTRY
EMERGENCY
ENT TO INPATIENT 18
HOSPITAL LOBBY
REGISTRATION TOI. ENTRANCE
RECEPTION PHARMACY
LADIES GENTS

ELE/TEL/DATA
TOI. TOI. PRAYER +750M FFL
RM.
ENT LOBBY
LVL+0.75
AHU
INPATIENT LOBBY

RECEPTION
WAITING
BOOK STORE CAFÉTARIA LIFT LOBBY
BOTTLE COLD STORE STAFF INCHARGE
WASH STORE RM. TOI.
VESTIBULE UP
(FOR BEDS) DN.
1800 WIDE FLORIST WAITING
CORRIDOR LADIES
DONER GENTS
BLOOD
MOVEMENT
BLEEDING BLOOD
MOVEMENT
TOI. TOI. BANK BOOK CAFETERIA PANTRY
MEDICAL
LAB COLLECTION EXAMIN.
STORE

STAFF
REST RM.
LIFT LOBBY-3
(FOR SERVICE) CH.CH.
BLOOD BANK
CH.CH. 12.1 13.1 14.1 15.1 16.1 17.1 18.1

CH.
CORRIDOR

IPD WAITING RECEPTION IPD


2450 WIDE

RESIDENT NURSE'S
REST RM. REST RM.
BLOCK B
TOI.

CH.
BLOCK-A
CONS'S
GENTS C
TOI.
CH. REST RM.

PUBLIC TOI.
H
BLOCK-B
GROUND FLOOR
007
Block C : 023
• It consists of the kitchen area, labs & diagnostics. 028
• Separate sections in kitchen for bulk cooking, main cooking, chapattis, salads & dish washing. 029
• The diagnostic wing consists of various labs and the radiology department like X ray, MRI,
ultrasound, CT scan etc. with separate waiting areas, toilets & change rooms. KITCHEN DIAGNOSTIC WING
LOADING UNLOADING LANDSCAPED COURTYARD
BELOW
C CONS'S
TOI.
REST RM.
H
2450 WIDE
CORRIDOR
FHC-6

STORE
FHC-7
UP CH. CH.
WAITING FOR WAITING FOR

ELE/TEL/DATA
SAMPLE RECEIVING CH. TOI. TOI. WAITING FOR WAITING FOR
MRI& CT SCAN CH.
& SORTING
+ 4.65 M FFL HEAMATOLOGY
NUCLEAR MEDI. CH.
DN. X-RAY ULTRASOUND
RECEPTION
CH. CH. RECEPTION
AHU
J

DISH WASH AHU CONS DW DW

CONSOLE
COMMON
ROOM GAMMA
PROCEDURE MRI US US

CORRIDOR
X-RAY SPECIAL

1800 WIDE
KITCHEN RM. CT X-RAY TOI.
SCAN PROC ROOM
BLOCK C CHAPATI SEC.

TANDOOR
SP COOKING
AREA
AHU FOR
LAB
COLD
STORE
BIO-CHEM IMMUNOLOGY COMMON
2450 WIDE
CORRIDOR
DOSE
ADMN. EQUIP. SCAN
ROOM 2450 WIDE
CORRIDOR
TOI.
FOOD PICK UP BY TROLLEY

ROOM EQUIP. CH.


K
MAIN COOKING
AREA
DIETICIAN
ORGAN
TISSUE
CONS.
CONSOLE DECON ROOM
ULTRASOUND
TOI.
RECEPTION DOUBLE HEIGHT
RM. CHEM ROOM
MAIN COOKING
HISTROLOGY WASH / FUTURE PHARM. LAB FUTURE
PROCEDURE
LOBBY
AREA
JUICE&SALAD
CLINIC
STER
STORE
GAMMA SCAN
TOI. EXPANSION
2450 WIDE
OPD
BULK COOKING
AREA STORE 1500 WIDE CORRIDOR EXAM
CORRIDOR
PREP
POT
WASH
OFFICE NIGHT COMMON CH. COMMON CH.
AREA
CYTOPATHOLOGY CONS. CONS. MICRO- PANTRY TOI.
PHYSICIST NUCLEAR CU DU DUTY
OFFICE PANTRY DARK
EXAM.
EXAM.
RM. RM.
PATHOLOGIST
RM. CH. IMIGING CONS.
PREP
BIO TOI.
&SECY
TOI. MEDI. TECH. CH.
RM. TOI.
L
AREA
ROOM

KITCHEN LABS DIAGNOSTICS


Block D: 19 20 21 22 23 24 25 26 27 28 29

• It consists of the main OPD area with GYMNASIUM


DN. UP
the Rehabilitation Centre.
• It has the main reception with enquiry
H

OPD ENTRY
2450 WIDE
CUT OUT ABOVE
CORRIDOR
counter.
ELE/TEL/DATA

• Various consultant rooms(4-6) with LVL+0.75 OPD LOBBY


examination rooms, inspection rooms & AHU
RECEPTION J
REGISTRATION
waiting areas are provided in the form PROCEDURE BILLING
RM. CASHING VESTIBULE VESTIBULE
of clusters. TOI. TOI.
0141G 0142D 0142E

LVL+0.75 0141F 0142C


GENTS
TROLLEY
BLOCK-C
• It also has the hydro, wax and LIFT LOBBY
CU DU
DR'S
DUTY
BACK
MANAGER'S OFFICE
FIRE
COMMAMD LADIES
0141C

0141D
0142B
TOI.
WH CHAIR
WAITING
OFFICE BLOCK-D
TOI. TOI. TOI. 0142A

physiotherapy areas. RM.


0141E RECP.
K
2450 WIDE
BLOCK D CORRIDOR ALL PARTITION
IN DRY WALL
REHABILATION THER

EXAM EXAM EXAM


INJEC
EXAM RM. EXAM
TOI. THERAPY COUNSEL COUNSEL THER GROUND FLOOR
CH.
THERAPY

GYMNASIUM
EXAM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. CONS RM. WAX BOX TH.
HYDRO 0143

THERAPY
L

OPD CONSULTATION REHAB


29 31 33 35 36
30 32 34
FIRST FLOOR PLAN Block C : 007
7
8 9 10
11
• This part basically consists of the Major O.T.s for 023
6 12
028
5

SINGLE ROOM
13

general surgeries including their pre-operative and


BLOCK A 3

SINGLE ROOM
4

BLOCK B 14

15

post-operative wards with conveniently located


029
2
16

SINGLE
SINGLE
SINGLE SINGLE ROOM FAMILY FAMILY SINGLE
ROOM
SINGLE SINGLE
SINGLE
nursing stations.• This block also contains the non-invasive
17

SINGLE ROOM ROOM ROOM ROOM DN UP ROOM ROOM ROOM SINGLE

SINGLE
SINGLE ROOM
SINGLE
ROOM
SINGLE
ROOM
ROOM

2450 WIDE
ROOM
ROOM SINGLE
ROOM SINGLE
ROOM SINGLE
• 18

Cardiac Labs having E.C.G.


ROOM SINGLE
SINGLE ROOM CORRIDOR ROOM SINGLE
SINGLE ROOM LADIES GENTS
(electrocardiography), TMT rooms & Colour

ELE / TEL/ DATA

ELE/TEL/DATA
TOI. ROOM SINGLE
SINGLE ROOM SLUICE
DU
TOI. DU SLUICE
A
SINGLE ROOM NURSE'S NURSE'S ROOM SINGLE
MSKP MSKP
DUTY DUTY ROOM SINGLE
ROOM
Doppler rooms with their waiting areas.
PANTRY PANTRY
STORE NURSE'S NURSE'S STORE
B STATION CH. TOI. FAMILY TOI. CH. STATION
ROOM SINGLE
PATIENT'S CU NURSE'S DOCTOR'S DOCTOR'S AHU ROOM AHU DOCTOR'S
DOCTOR'S NURSE'S CU PATIENT'S ROOM
NURSE'S LOUNGE LOUNGE
STATION LOUNGE INCHARGE DUTY
TOI. TOI. TOI. TOI. DUTY INCHARGE LOUNGE NURSE'S
C
UP STATION
2450 WIDE
DN.
LVL +4.65M 2450 WIDE
CORRIDOR CORRIDOR LIFT LOBBY LVL +4.65M
(FOR BEDS) UP
DN
D

DOUBLE DOUBLE DOUBLE DOUBLE SINGLE DOUBLE DOUBLE DOUBLE


DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE
ROOM ROOM ROOM ROOM ROOM ROOM
ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM
E

LIFT LOBBY
DOUBLE ROOM
DOUBLE ROOM (FOR SERVICE)
12.1 13.1 14.1 15.1 16.1 17.1 18.1
N
0.8 1.8 2.8 3.8 4.8 5.8

FIRST FLOOR LEVEL


OT

CORRIDOR
2450 WIDE
TOI.

NON INHASIVE CARDIAC LAB RECEPTION CUM WAITING UP DN


C

Lvl. = + 4.65m H
TOI.

2450 WIDE
H

CORRIDOR LVL +4.65M 2450 WIDE


CORRIDOR DOUBLE HEIGHT

Block A & B :
FHC-6

UP TOI.
STAFF'S
STAFF'S

ELE/TEL/DATA
WAITING FOR DN

ELE/TEL/DATA
WHEEL
FUTURE
CLEAN SUPPLY
NON INHASIVE
TOI. LOUNGE
UP.

WAITING WARDS LOUNGE SROTING


DN CHAIR
VISITOR'S EXPAN. CARDIAC LAB
TOI. DR'S
AHU LVL +4.65M

TOI. 1500 WIDE UP
STORE LOUNGE
DN.

It basically consists of J
CORRIDOR

STORE RECEPTION CH. CH. PULMONOLOGY


STORE NEUROLOGY
SAMPLE
COLL. GENTS
J

LADIES TOI.
WARDS FOR POST DECONT OFF.
LAB

single rooms on one side & OPERATIONAL


NURSE'S
STATION TOI. TOI.
PRE OPERATIONAL
STORE RM
RECOVERY 2450 WIDE
CORRIDOR
TOI.
TOI.
RECEPTION TOI. TOI. WAITING
DR'S TOI.
BEDS DU
BEDS STORE FUTURE FUTURE
RM. WAITING AMBULATORY AMBULATORY DU CU DUTY
CU STORE CU DU TOI. LAB PROCUDURE

double rooms on the other K


2450 WIDE
PANTRY STORE EXPAN. EXPAN.
2450 WIDE
JANITOR'S TOI.
RM.
2450 WIDE
THERAPY THERAPY
RM.

2450 WIDE
RM.
PANTRY
K

CORRIDOR CORRIDOR CORRIDOR CORRIDOR

side with centrally placed 1. SCRUB SCRUB ECG 1.


TMT1. 1. COLOUR
DOPPLER
CDS
1. EXAM. EXAM. INJEC EXAM. INJEC EXAM. INJEC EXAM. INJEC EXAM. INJEC EXAM. INJEC EXAM.

CH. CH. CH. MAJOR MINOR 2. FUTURE ENDOSCOPY REPORTING


2. 2. 2.
HOLTER
2.
RM. RM. RM. RM. RM. RM.

nursing stations. OT OT
3.
EXPANSION
ENDOSCOPY
RM.
3. 3. 3.
LAB
3. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM. CONS. RM.


L L

The rest of the area


• includesstores,lockers, pantry, A.H.U. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

OPERATION CONS. RM.


& duty units etc. THEATRES
• There are 4 types of wards : BLOCK C BLOCK D
• Single seaters – size 3.415m x 4.5m. Block D :
Placement of bed is such that the patient • It mainly houses the Cardiac OPD, specialty
gets maximum left hand side lighting. clinics & health maintainance clinic with their
• Double seaters – size 3.415m x 6.0m. consultant rooms & waiting areas.
It is divided into two units with low ht. • It also has some labs like Neurology &
partitions of foldable type. Distance CONSULTATION ROOM VIP ROOM Pulmonology with their sample collection & DR’S ROOM
between two beds = 1.5m waiting areas.
• Double deluxe type – size is double to
that of double seater. One toilet, no
partition, 2 beds for patients & 2 for
accomplices.
• VIP suites – Two single seaters DOUBLE SEATER
combine to form one VIP suite. 4 SEATER
CARDIAC OPD WAITING CONSULTANT
ROOMS
second floor plan 5
6
7
8 9 10
11
12
13
O.T. COMPLEX 007
4
FAMILY 14
• LOCATION: 1st floor & above very near to Surgical 023
3
ICU WARD ICU WARD BLOCK B 15

wards & SICU 028


2
16

1
ISO
ROOM
TOI. FAMILY FAMILY
ROOM
TOI. ISO
ROOM
17 • CORRIDORS : 3 - 3.5 m width for easy movements 029
BLOCK A CH.
VESTIBULE
ROOM DN
UP CH.
VESTIBULE 18 of men & machines
ICU WARD LADIES FAMILY GENTS
• Zone wise distribution of the area so as to avoid

ELE/TEL/DATA

ELE/TEL/DATA
TOI. TOI. SLUICE
LVL +8.55M NURSE'S
DUTY
NURSE'S
LOUNGE
DU
ROOM DU
MSKP crisscross movements of men &machine

STATION
NURSE'S
TOI.
B

NURSE'S
TOI. TOI.
DR'S
DUTY
NURSE'S
DUTY
CU
AHU AHU
JANITOR
NURSES'
DUTY
CU DR'S
STORE CHIEF OF
NURSE'S
FAMILY
ICU WARD
• Provision for emergency exit
STATION TOI. RM. LOUNGE

RM. TOI.
C
UP
DN. 2450 WIDE LVL +8.55M
NURSE'S
STATION
OPERATION ROOMS: –No. & size as per the
CORRIDOR LIFT LOBBY
ICU WARD TOI. SCRUB
SHOES
(FOR BEDS)
SHOES
TOI. VESTIBULE
UP
DN requirement(50% of the surgical beds) Size
FAMILY
VESTIBULE
SCRUB
D TOI. TOI.
SLUICE SLUICE
PANTRY 1200 WIDE 1200 WIDE PANTRY
ICU WARD
ISOLATION LOCKERS
STAFF
CH.
RM.
CORRIDOR
LOCKERS
GENTS
CH.
RM.
LOCKERS
LADIES
CH.
RM.
PHARMACY LOCKERS
GENTS
CH.
RM.
CORRIDOR
LOCKERS
LADIES
CH.
RM.
LOCKERS
STAFF
CH.
RM.
ISOLATION
20’X20’X10’

E

LIFT LOBBY-3 STAT


Glass windows one side only
(FOR SERVICE) LAB

N • Sliding door, (2 Flap door,1.5 mts.)


ICU WARD
12.1 13.1 14.1 15.1
DRS' 16.1 17.1 18.1

LOUNGE
FAMILY

CORRIDOR
0.8 1.8 2.8 3.8 4.8 5.8

2450 WIDE
F
CHIEF
SURGEON
ICU WARD

SECOND FLOOR LEVEL : TOI.

TOI.
CHIEF
ANATHESIATIST
CHIEF
CARDIOLOGIST CH.RMS.
CATH LAB
DN. UP
Block D:
• •
C

Lvl. = + 8.55m H
TOI.
2450 WIDE
CORRIDOR LVL +8.55M
2450 WIDE
CORRIDOR
2450 WIDE
CORRIDOR
H
It basically has
Block A & B: the invasive
FHC-6
UP 2450 WIDE 2450 WIDE
CH. CH.
LVL +8.55M STORE

ELE/TEL/DATA
ELE/TEL/DATA
CORRIDOR CORRIDOR

DN. STAFF RM. RM.


CONF.
CORRIDOR
TROLLEY DR'S
DARK
OPERATION
2450 WIDE

DR'S RM. PREP. STERILE CH.RM. LOUNGE


RM. NURSE'S
OT
DECONTAMINATION
ROOM-6 AHU CATH LAB
Both these blocks have ICUs J

DOCTORS'
CONTROL WORKSHOP

OPERATION
SCRUB

MOBILE
CARM
TROLLEY
PREP.
FAM
STORAGE
SCRUB
TOI. TOI.
CU STATION
J cardiac lab
ANAESTHESIST
DR'S NURSES' UPS CU SCRUB WARDS
(Intensive Care Units).
TOI. CH.RM.
ANAESTHESIA
LOUNGE ROOM-1

PROFUSION
STERILE
CORE PROFUSION
CH.RM.
DONOR
RM.
TECH.
RM.
ENTRANCE
LOBBY
TOI. TOI.
including 3
TOI. NURSES' TROLLEY PROPOSED
ROOM
Right next to the entrances K
TERRACE
CH.RM.

STAFF
SLUICE
RM. CU BAY
ROOM PARTITION
DOCTORS'
CH.RM. LVL +8.55M PANTRY TROLLEY
DU
K Cath. Labs with
TOI. CONTROL CATHETER CATH PRE.OP BEDS
CH.RM.
are separate change rooms POST OF
BEDS OPERATION
OPERATION OPERATION OPERATION
CATH
SWING LAB
ROOM

TECHNICAL
CATH
SWING LAB
STORE INCHARGE
CATH RECOVERY separate
TOI. ROOM-3 STAFF'S DOCTORS' OFFICE OFFICE PRE.OP BEDS
PRE.OP BEDS
BEDS
WARD BOY'S
ROOM-4 ROOM-5 ROOM
& lockers for gents, ladies REST ROOM
ROOM-2
2450 WIDE
CORRIDOR
SCRUB SCRUB

2450 WIDE
CORRIDOR
LOUNGE LOUNGE
EQUIP.RM. recovery areas.
& staff. L

CH.RMS. CATH
L

They have the nursing 19 20 21 22 23 24 25 26 27 28


LOUNGE
29
SWING LAB 30 31 32 33 34 35 36

stations, toilets & doctor’s


duty rooms located in the
central place. ICU

ENTRANCE

Block C: (OT complex )


• It comprises of the Cardiac OTs.
• The OT complex basically has 3 zones :-
• Outer Zone : Consisting of the entry for
doctors, staff & patient. • Innermost zone : OTs, Scrub area & patient holding areas (Pre & Post operative room) having
• Intermediate zone : Comprising of the storage highest level of sterilization.
areas, change rooms, nurse’s room & doctor’s • Also it has a storage room for sterilized equipments & linen, essential drugs, blood supply &
lounge. X-ray machine.
• Both these areas combine to form the Sub- • There are 6 OTs ( 9875mm x 9875mm each) arranged around a common sterilized area.
Sterile area. • Dumbwaiters connect the OT complex to CSSD for direct supply of sterilized equipments.
third floor plan 7
8 9 10
11
Block C:
• It is composed of a Dining Hall ( Café Jamjee), terrace
4
5
6
SINGLE
ROOM
12

BLOCK B
13

14

3 SINGLE 15 garden & a dialysis unit on one side & a nursing school
ROOM
BLOCK A
1
2
16
with 2 lecture halls & a conference room etc.
SINGLE SINGLE FAMILY FAMILY SINGLE SINGLE 17
SINGLE ROOM SINGLE
SINGLE ROOM ROOM ROOM DN. ROOM ROOM SINGLE
SINGLE ROOM UP.
ROOM
ROOM ROOM SINGLE
SINGLE ROOM ROOM SINGLE 18

SINGLE ROOM ROOM


2450 WIDE SINGLE
SINGLE ROOM CORRIDOR ROOM SINGLE
SINGLE ROOM LADIES GENT'S

ELE/TEL/DATA
ELE/TEL/DATA
ROOM
ROOM TOI. TOI. SINGLE
SINGLE NURSE'S DU DU ROOM

NURSE'S STATION
ROOM

STATION
NURSE'S
DUTY
B
STORE PANTRY
TOI. TOI.
DR'S CH LOBBY CH. DR'S
PANTRY
STORE WARD
NURSE'S PATIENT'S
LOUNGE
CU NURSE'S DOCTOR'S
DUTY
LOUNGE AHU AHU LOUNGE NURSE'S CU PATIENT'S
2450 WIDE STATION INCHARGE INCHARGE LOUNGE
C CORRIDOR TOI. TOI. NURSE'S
UP STATION
DN. 2450 WIDE
CORRIDOR
LVL+12.45M LVL+12.45M CAFÉ JAMJEE LECTURE HALL
LIFT LOBBY
(FOR BEDS)
UP
DN TERRACE GARDEN
D
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
GENERAL
WARDS
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM
DOUBLE
ROOM WARD
Block D:
E
• It is basically the board room & administrative areas

LIFT LOBBY-3
DOUBLE
ROOM
(FOR SERVICE)
12.1 13.1 14.1 15.1 16.1 17.1 18.1 N It has some offices, 3 meeting rooms & area for
0.8 1.8 2.8 3.8 4.8 5.8 DOUBLE ROOMS
F

LVL+12.45M
future expansion.
TOI.
STAFF RECREATION RM.
OXYGEN&VACCUM LIBRARY OFFICES
THIRD FLOOR LEVEL :
DN. UP
C
TOI.
H H
RECEPTION
2450 WIDE TOI. TOI.


LIBRARIAN
Lvl. = + 12.45m FHC-6
CORRIDOR
UP LADIES GENTS
FUTURE
EXPANSION PERITONIAL BI-CARBONATE
DIALYSIS UP
OFFICE SECY OFFICE OFFICE OFFICE

ELE/TEL/DATA
DIALYSIS
ELE/TEL/DATA

WASH TOI. GENTS


TOI. WAITING
DN. CH.
LIBRARY TOI.
LVL+12.45M
Block A & B: J AHU
TOI.
LADIES
AHU DN
2450 WIDE
CORRIDOR
JAN J

CORRIDOR
1822 WIDE
DINING RM DW DW TOI. MEETING WAITING

STORE
PANTRY WASH LVL+12.45M
It is similar to the First DRS'
CHAMBER SUPPORT ISOLATION ISOLATION
RM. RM.
WASH

STORE
FILTER
SERVER WAITING ROOM ROOM LADIES
TOI.
GENT'S
TOI.
OPEN
MEETING MEETING
TERRACE OFFICES
floor level. These K
ROOM ROOM PANTRY
K

DINING RM LVL+12.45M STAFF


blocks have single and NURSES'S DOCTOR'S EDP STAFF
ADMN
SENIOR STAFF STAFF DOCU.
TRAINING TRAINING BOARD
double rooms. DINING
SYNDICATE SYNDICATE
ROOM ROOM TRAINING LT ROOM ROOM HEAD HEAD HEAD HEAD HEAD HEAD
HEAD HEAD PR MARK. FINANCE ADMN. LEGAL ADMN.
L L

19 20 21
DINING RM
22 23
BLOCK C 24 25 26
TRAINING RMS. 27 28 29 30 31 32 33 34 35 36

MEETING & WATER


THE FORTIS INN : BOARD RM TANK AND

BUILDING SERVICES :
PUMP
30 well-furnished rooms including suites with attached baths. ROOM
 It has two types of floors- standard and executive having their IN
own set of Deluxe, Super Deluxe rooms and suites.  Water supply : BASEMENT

 There are 6 water storage tanks in hospital, which have


been, constructed underground :
DHAULPUR STONE  Fire- water tanks- 3 nos.
 Treated water tanks -2nos.
DELUXE ROOM
PHARMACY  Raw water tanks – 1 no Raw water is treated ,pumped
ELEVATIONAL FEATURES : to elevated storage tanks, distributed to different inlets at PUMP
 Red Agra stone has been used for external different floors ROOM
cladding along with Dhaulpur stone strips.  Estimate of quantity of water (inc. laundry)= 450 litres
 For curtain wall, blue glass from Belgium per head per day.
along with double insulated glass for  STP (Sewage Treatment Plant)
windows has been used. • To treat all the waste water and sewage waste, sewage 007
 The glazing induces verticality while the treatment plant has been provided which is located on 023
DOUBLE GLASS 028
horizontal bands break the verticality thus the right side of the IPD entrance while facing 029
achieving a balanced composition. Emergency.
HVAC (Heat Ventilation & Air Conditioning unit) : 007
023
• The whole building is centrally air conditioned with toilets have ventilators opening in shafts. 028
• Air changes are provided by mechanical means : wards- 3 ch/hr, kitchen – 10 ch/ hr, bathrooms & WCs – 3 ch/hr, OTs – 12 ch/hr. 029

Procedure :
• Water-cooled chiller has been used.
• Basically the medium is chilled water.
• Pipes take the water to the FCUs ( Fan coil unit) & further to the AHUs ( Air Handling Unit).
• Chilled water comes in contact with the air & cools it.
• Chilled air is then distributed by ducts to diffusers and vents.
VIEW OF A.C. PLANT
 FIRE FIGHTING : IN BASEMENT
COOLING TOWERS AT ROOF

• Fire-resistant construction has been done using AAC blocks ( autoclaved aerated concrete blocks).
• Sprinklers have been provided @ approx. 3000mm depending upon equal distribution of width of hall
available.
Two types of detectors have been used :
 Smoke sensors
 Heat sensor
•In the basement-parking areas: foam extinguishers for controlling oil fires. FIRE PROTECTIORS NEAR
•Hose-reels in fire-fighting niches 4’x4’ have been used. HOSE REELS
THE STAIRCASE
•Public address system & hooters have been placed strategically.
•Fire exit routes with automatic opening type doors have been provided
 ELECTRICAL :
• HT (High Tension) regulators provided to regulate voltage fluctuations with 2 step down SPRINKLER
transformers.
• In case of power failure diesel generators start automatically.
• UPS- 2 no. caters to power requirements of the Hospital Information System, Emergency, lighting
of entire hospital & all OTs.
• Colour of switches :UPS sockets- gray, normal sockets – white
 BOILERS:
• Location – Basement, Block B HT PANEL ROOM
• 5 boilers (600 kg/hr. each) are installed.
DUCT IN THE BASEMENT COVERED WITH GENERATOR ROOM
• Steam from the boiler is fed to the laundry, kitchen, CSSD etc. for ALUMINUM FOIL
hot water system.
 REVERSE OSMOSIS WATER PLANT:  SOFT WATER PLANT :
•Location – Basement, Block B •Location – Basement, Block B
•It has been installed to produce ultra pure clean water, which •Soft water here produced is used for steam
is used in scrubs, OTs, Cath labs, ICUs & CSSD. boilers.
 SEWERAGE : FINISHES :
 All toilets have shafts adjoining to carry waste disposal pipes and water supply lines. DOORS :
 Soil pipes have been laid to 1:60 slope. • Two types of doors have been provided. The ones with cedar
 DRAINAGE : laminates are for patient entry and the ones with green
 For basement, sump wells have been provided at intervals where waste water is laminates are not for patient entry.
collected and pumped out to the manholes. TYPES OF FLOORING :
 Curb inlets are provided at the edges of the roads to drain the water. • Public areas : Marble
 MEDICAL GASES MANIFOLD : • Patient areas : Mosaic
 Location : It is located behind kitchen in the basement right in front of staff • OTs : Granite
parking entrance. • ICUs : PVC CEDAR LAMINATES
 The pipe line starts from gas plant & carried out till the last point at the bedside. • Radiology : PVC
Laid along the walls in different colours. Outlets are provided at 4 ft.- 5ft 6in. • Nuclear medicine : PVC
above floor level. • Public staircases : Marble
• Fire-escape staircases : Kota Stone
Colour coding of these lines : • Concrete blocks have been used for pavements.
• Oxygen : yellow with white bands • Ceramic tiles have been used in various colours and sizes.
• Nitrous oxide : yellow with blue bands • Chemically resistant tiles for labs.
• Compressed air : blue with white bands • The interiors have been plastered and painted.
Liquid oxygen storage
• Vacuum : blue with black bands COLOUR CODING tank placed in open in • Prefabricated furniture which is easily portable & movable has
• AGSS : red (Anesthetic gas scavenging system) order to avoid any risks
been provided.
due to its combustible

 STRUCTURAL DETAILS :
nature

• Raft footing has been provided. (Combined footing)


• The grid is a combination of radial and square grid.
• RCC columns of variable sizes.
• Circular columns in basement- 850 mm dia, DADO ON THE WALL OF CAFÉ ,MARBLE GRANITE
• On rest of the floors : 700 mm dia. AAC CONCRETE BLOCK
JAMJEE

• Retaining wall 9 inches thick.


COLUMNS
 CONSTRUCTIONAL DETAILS : CLADDED
WITH BEIGE
• RCC construction SANDSTONE
• First class bricks & AAC blocks used
• As the hospital falls on aviation route, measures have
• been taken to reduce the sound level inside the hospital : DOUBLE GLASS WINDOWS
• AAC (autoclaved aerated concrete blocks) have been used. RED
• Acoustic false ceiling tiles have been used. SANDSTONE
• For windows double glass has been used
• AAC blocks : 39 x 19 x 30 cms. For outer load bearing 007
walls RED SANDSTONE 023
CLADDING 028
• AAC blocks : 39 x 19 x 10 cms. For inner load bearing 029
walls
 DESIGN/CRITICAL ANALYSIS :
007
023
028
• A unique feature of this hospital is its usage of space. 029
• Separate entry for OPD, IPD, Emergency and Service zone : thus segregating the traffic flow.
• A flexible & modular approach imbibed to impart adaptability to the future changes & modifications.
• The OPD has been kept on the ground and first floor : thus providing easy accessibility for patients and their attendants.
• OPD placed next to diagnostic : easy access.
• The CSSD has been placed below the OT area hence direct connection via dumbwaiters.
• A very long well-landscaped courtyard has been placed in the centre, thus providing natural light in corridors.
• Waiting areas for all OPDs are provided in the form of small clusters.
• Vertical circulation in the form of stairs and lifts is separate for all blocks.
• The shafts provided for maintainance are narrow, thus leading to inconvenience.
• Administration is provided on the third floor which is too far from the scope of visitors.
• Basement enterance is on the rear side and cannot be approached from one chance.
• Reception and cafeteria in the i.P.D. Block are quite near to each other which causes lot of confusion near the entrance.

LIFT STANDARDS ON SITE ANALYSIS


REQ. PRESENT
Multipurpose/bed lift 1/100 beds 5 4

Staff lift 2/100 beds 10 6

STAIRCASE STANDARDS ON SITE ANALYSIS


CORRIDORS STANDARDS ON SITE ANALYSIS

Tread 300mm 300mm


Access corridor Min. 1.5m 1.8m wide
wide
Riser 150mm 150mm
Patient’s Min. 2.25m 2.45m wide
corridor or wide Width 1.5m-2.4m 2.1m wide
clean corridor wide
Main / spine Min. 3m 2.45m wide Handrail 1m high and 0.8m high
corridor wide on both and only on
Doubly loaded Min. 3m 2.45m wide sides of the one side of
corridor wide flight the flight

You might also like