MBS AG

EEH1115
Three-phase energy transformer meter
AC energy transformer meter, suitable for clip-on to 35 mm DIN rail

Type of energy meter EEH1115xxxx


xxxx declaring the primary current is absolutely necessary
Mains 4-wire L-N (230 V)
rated voltage UN 230 V
tolerance value -20 %... +15 %
consumption < 3.0 VA
frequency 50 Hz
frequency range 45...65 Hz

Output 1 S0-impulse output


drawing
optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1000 Imp/kWh
connection terminal 40 / 41
(option)
communication RS485 EEH1315xxxx
connection multi-drop
cable type screened, wound pair
max. cable length 1000 m
connection terminal screw
isolation 3.7 kV rms for 1 min. between
all meters and other units
transmission system asynchronous
format type MODBUS RTU
transmission time 1200 to 19200 bits/s
diagram connection A and B 120 Ohm
max. linked meters 32

Counter 1 counter meter for active energy


electro-mechanical meter
number of digits 7 (6.1 digits)
digit height 4 mm
digit width 1.2 mm
diagram LED test 1000 Imp/kWh (red)
LED operation status (red)
(option) reactive energy EEH1105xxxx

Current range 5A
nominal current I N 5A
max. current Imax 6A
consumption < 0.02 W/current path
start current 0.002 IN
(option) nominal current IN 1A EEH1111xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 5 A or 1 A
will be supplied
Technical data
approbations
option EEH5115xxxx active energy EN 61036 class 1
equally load phases reactive energy EN 61268 class 2
construction housing PA6.6 in conformity with UL 94 V-0
dimensions (mm) 108 x 90 x 72
weight 0.6 kg
mounting DIN rail acc. to DIN EN 50022
climatic conditions EN 61036 interior meter
ambient temperature operation -20 °C to +55 °C
storage -25 °C to +70 °C
protection class 2
current terminals < 10 mm2
control terminals < 2.5 mm2

306 www.mbs-ag.com
MBS AG

EEH1125
Three-phase energy transformer meter
AC energy transformer meter for dual tariff, suitable for clip-on to 35 mm DIN rail

Type of energy meter EEH1125xxxx


xxxx declaring the primary current is absolutely necessary
Mains 4-wire L-N (230 V)
rated voltage UN 230 V
tolerance value -20 %...+15 %
consumption < 3.0 W/phase
frequency 50 Hz
frequency range 45...65 Hz
Output 1 S0-impulse output
drawing optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1000 Imp/kWh
connection terminal 40 / 41 / 42
(option)
communication RS485 EEH1425xxxx
connection multi-drop
cable type screened, wound pair
max. cable length 1000 m
connection terminal screw
isolation 3.7 kV rms for 1 min. between
all meters and other units
transmission system asynchronous
format type MODBUS RTU
transmission time 1200 to 19200 bits/s
diagram connection A and B 120 Ohm
max. linked meters 32
Counter 2 counter meters for active energy HT-NT (kWh)
2 electro-mechanical meters
number of digits 7 (6.1 digits)
digit height 4 mm
digit width 1.2 mm
LED test 1000 Imp/kWh (red)
LED operation status (tariffs) (red)
diagram (option)
2 meters for active/reactive energy (kWh/kvarh) EEH1235xxxx
2 meters for active energy (import/export) (kWh) EEH1245xxxx
Current range 5A
nominal current I N 5A
max. current I max 6A
consumption < 0.02 W/current path
start current 0.002 IN
(option) nominal current IN 1A EEH1221xxxx
Primary current 0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied
Technical data
approbations
active energy EN 61036 class 1
reactive energy EN 61268 class 2
option EEH5225 construction housing PA6.6 in conformity
equally load phases with UL 94 V-0
dimensions (mm) 108 x 90 x 72
weight 0.6 kg
mounting DIN rail acc. to DIN EN 50022
climatic conditions EN 61036 interior meter
ambient temperature operation -20 °C to +55 °C
storage -25 °C to +70 °C
protection class 2
current terminals < 10 mm2
control terminals < 2.5 mm2
tariff start 230 V AC
Tariff 2 is energized when terminals 13 and 15 are under load
of 230 V AC.

www.mbs-ag.com 307
MBS AG

EEH1175
Three-phase energy transformer meter
AC energy transformer meter for dual tariff, suitable for clip-on to 35 mm DIN rail

Type of energy meter EEH1175xxxx


xxxx declaring the primary current is absolutely necessary
Mains 4-wire L-N (230 V)
rated voltage UN 230 V
tolerance value -20 %...+15 %
consumption < 3.0 W
photo is similar to the original frequency 50 Hz
frequency range 45...65 Hz
Output 1 S0-impulse output
drawing optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1000 Imp/kWh
connection terminal 40 / 41
(option)
communication RS485 EEH1475xxxx
connection multi-drop
cable type screened, wound pair
max. cable length 1000 m
connection terminal screw
isolation 3.7 kV rms for 1 min. between
all meters and other units
transmission system asynchronous
format type MODBUS RTU
transmission time 1200 to 19200 bits/s
connection A and B 120 Ohm
diagram
max. linked meters 32

Counter LCD counter meter for active energy HT-NT (kWh)


number of digits 2 x 9 (8.1-digits)
digit height 4.86 mm
digit width 2.96 mm
(option)
2 meters for active/reactive energy (kWh/kvarh) EEH1285xxxx
2 meters for active energy (import/export) (kWh) EEH1295xxxx

Current range 5A
nominal current I N 5A
max. current I max 6A
consumption < 0.02 W/current path
start current 0.002 IN
(option) nominal current IN 1A EEH1271xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 5 A or 1 A
will be supplied
Technical data
approbations
active energy EN 61036 class 1
reactive energy EN 61268 class 2
option EEH5275xxxx construction housing PA6.6 in conformity with UL 94 V-0
equally load phases dimensions (mm) 108 x 90 x 72
weight 0.6 kg
mounting DIN rail acc. to DIN EN 50022
climatic conditions EN 61036 interior meter
ambient temperature operation -20 °C to +55 °C
storage -25 °C to +70 °C
protection class 2
current terminals < 10 mm2
control terminals < 2.5 mm2
tariff start 230 V AC
Tariff 2 is energized when terminals 13 and 15 are under load
of 230 V AC.

308 www.mbs-ag.com
MBS AG

EEH2115
Three-phase energy transformer meter
AC energy transformer meter for clip-on to 35 mm DIN rail

Type of energy meter EEH2115xxxx


xxxx declaring the primary current is absolutely necessary
Mains 3-wire L-L (400 V)
rated voltage UN 230 V
tolerance value –20 %...+15 %
consumption < 3.0 W/phase
photo is similar to the original frequency 50 Hz
frequency range 45...65 Hz

drawing Output 1 S0-impulse output


optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1000 Imp/kWh
connection terminal 40 / 41
(option)
communication RS485 EEH2315xxxx
connection multi-drop
cable type screened, wound pair
max. cable length 1000 m
connection terminal screw
isolation 3.7 kV rms for 1 min. between
all meters and other units
transmission system asynchronous
format type MODBUS RTU
transmission time 1200 to 19200 bits/s
diagram
connection A and B 120 Ohm
max. linked meters 32

Counter 1 counter meter for active energy (kWh)


electro-mechanical meter
number of digits 7 (6.1 digits)
digit height 4 mm
digit width 1.2 mm
LED test 1000 Imp/kWh (red)
LED operation status (red)
(option) reactive energy (kvarh) EEH2105xxxx

Current range 5A
nominal current I N 5A
max. current Imax 6A
consumption < 0.02 W/current path
start current 0.002 I N
(option) nominal current I N 1A EEH2111xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 5 A or 1 A
will be supplied
Technical data
approbations
option EEH8115xxxx active energy EN 61036 class 1
equally load phases reactive energy EN 61268 class 2
construction housing PA6.6 in conformity with UL 94 V-0
dimensions (mm) 108 x 90 x 72
weight 0.6 kg
mounting DIN rail acc. to DIN EN 50022
climatic conditions EN 61036 interior meter
ambient temperature operation -20 °C to +55 °C
storage -25 °C to +70 °C
protection class 2
current terminals < 10 mm2
control terminals < 2.5 mm2

www.mbs-ag.com 309
MBS AG

EEH2125
Three-phase energy transformer meter
AC energy transformer meter for dual tariff for clip-on to 35 mm DIN rail

Type of energy meter EEH2125xxxx


xxxx declaring the primary current is absolutely necessary
Mains 3-wire L-L (400 V)
rated voltage UN 230 V
tolerance value -20 %...+15 %
consumption < 3.0 W/phase
photo is similar to the original frequency 50 Hz
frequency range 45...65 Hz
Output 1 S0-impulse output
drawing optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1000 Imp/kWh
connection terminal 40 / 41 / 42
(option)
communication RS485 EEH2425xxxx
connection multi-drop
cable type screened, wound pair
max. cable length 1000 m
connection terminal screw
isolation 3.7 kV rms for 1 min. between
all meters and other units
transmission system asynchronous
format type MODBUS RTU
transmission time 1200 to 19200 bits/s
diagram connection A and B 120 Ohm
max. linked meters 32
Counter 2 counter meters for active energy HT-NT (kWh)
2 electro-mechanical meters
number of digits 7 (6.1 digits)
digit height 4 mm
digit width 1.2 mm
LED test 1000 Imp/kWh (red)
LED operation status (tariffs) (red)
(option)
2 meters for active/reactive energy (kWh/kvarh) EEH2235xxxx
2 meters for active energy (kWh) EEH2245xxxx
Current range 5A
nominal current IN 5A
max. current Imax 6A
consumption < 0.02 W/current path
start current 0.002 IN
(option) nominal current IN 1A EEH2221xxxx
Primary current 0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied.
Technical data
approbations
active energy EN 61036 class 1
reactive energy EN 61268 class 2
option EEH8225xxxx construction housing PA6.6 in conformity with UL 94 V-0
equally load phases dimensions (mm) 108 x 90 x 72
weight 0.6 kg
mounting DIN rail acc. to DIN EN 50022
climatic conditions EN 61036 interior meter
operating temperature -20 °C to +55 °C
storage temperature -25 °C to +70 °C
protection class 2
current terminals < 10 mm2
control terminals < 2.5 mm2
tariff start 230 V AC
Tariff 2 is energized when terminals 13 and 15 are under load
of 230 V AC.

310 www.mbs-ag.com
MBS AG

EEH2175
Three-phase energy transformer meter
AC energy transformer meter for dual tariff for clip-on to 35 mm DIN rail

Type of energy meter EEH2175xxxx


xxxx declaring the primary current is absolutely necessary
Mains 3-wire L-L (400 V)
rated voltage UN 230 V
tolerance value -20 %...+15 %
consumption < 3.0 W
photo is similar to the original frequency 50 Hz
frequency range 45...65 Hz
Output 1 S0-impulse output
drawing optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1000 Imp/kWh
connection terminal 40 / 41
(option)
communication RS485 EEH2475xxxx
connection multi-drop
cable type screened, wound pair
max. cable length 1000 m
connection terminal screw
isolation 3.7 kV rms for 1 min. between
all meters and other units
transmission system asynchronous
format type MODBUS RTU
transmission time 1200 to 19200 bits/s
connection A and B 120 Ohm
diagram
max. linked meters 32

Counter LCD counter meter for active energy HT-NT (kWh)


number of digits 2 x 9 (8.1 digits)
digit height 4.86 mm
digit width 2.96 mm
(option)
2 meters for active/reactice energy (kWh/kvarh) EEH2285xxxx
2 meters for active energy (import/export) (kWh) EEH2295xxxx

Current range 5A
nominal current I N 5A
max. current Imax 6A
consumption < 0.02 W/current path
start current 0.002 IN
(option) nominal current IN 1A EEH2271xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 5 A or 1 A
will be supplied
Technical data
approbations
active energy EN 61036 class 1
reactive energy EN 61268 class 2
option EEH8275xxxx construction housing PA6.6 in conformity with UL 94 V-0
equally load phases dimensions (mm) 108 x 90 x 72
weight 0.6 kg
mounting DIN rail acc. to DIN EN 50022
climatic conditions EN 61036 interior meter
ambient temperature operation -20 °C to +55 °C
storage -25 °C to +70 °C
protection class 2
current terminals < 10 mm2
control terminals < 2.5 mm2
tariff start 230 V AC
Tariff 2 is energized when terminals 13 and 15 are under load
of 230 V AC.

www.mbs-ag.com 311
MBS AG

EWS1915
Three-phase energy transformer meter
AC energy transformer meter for clip-on to 35 mm DIN rail

Type of energy meter EWS1915xxxx


xxxx declaring the primary current is absolutely necessary
Mains 4-wire L-N (230 V)
rated voltage UN 57 V, 100 V, 230 V, 400 V
tolerance value -20 %...+20 %
consumption < 3.0 W/phase
photo is similar to the original frequency 50 Hz
frequency range 45...65 Hz

drawing Output 1 relay impulse output


relay 250 V, 6 A, 50 Hz
impulse duration 100 ms
max. load 1500 W
output impulse 1 Imp/kWh
max. impulse 4000/h
(option) EWS1115xxxx
optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1 Imp/Wh (30...250 A)
output impulse 10 Imp/Wh (300...2000 A)
impedance 100 Ohm

Counter 1 counter meter for active energy (kWh)


diagram electro-mechanical meter
number of digits 7 (7.0 digits)
digit height 4 mm
digit width 1.2 mm
LED test 8 Imp/kWh

Current range xxxx/5 A (dip-switch setting)


nominal current I N 5A
max. current I max 6A
consumption < 0.1 W/current path
start current 0.002 IN
(option) nominal current IN xxxx/1 A EWS1911xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied
Technical data
approbations
active energy EN 61036 class 1
construction polycarbonate housing acc. to UL 94 V-0
colour RAL 7035
dimensions (mm) 106 x 90 x 58
weight 0.3 kg
option EWS5915xxxx
mounting DIN rail acc. to DIN EN 50022
equally load phases
ambient temperature operation -10 °C to +60 °C
storage -40 °C to +70 °C
protection class 2

setting of the 4-pole dip switch

deviating primary currents are programmed at works


according to the details of the order.

312 www.mbs-ag.com
MBS AG

EWS1945
Three-phase energy transformer meter
AC energy transformer meter for clip-on to 35 mm DIN rail

Type of energy meter EWS1945xxxx


xxxx declaring the primary current is absolutely necessary

Mains 4-wire L-N (230 V)


rated voltage U N 57 V, 100 V, 230 V, 400 V
tolerance value -20 %...+20 %
photo is similar to the original consumption < 3.0 W/phase
frequency 50 Hz
frequency range 45...65 Hz
drawing
Output 1 relay impulse output
relay 250 V, 6 A, 50 Hz
impulse duration 100 ms
max. load 1500 W
output impulse 1 Imp/kWh
max. impulse 4000/h
(option) EWS1145xxxx
optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1 Imp/Wh (30...250 A)
output impulse 10 Imp/Wh (300...2000 A)
impedance 100 Ohm

Counter 2 counter meters for active energy (import/export) (kWh)


diagram
2 electro-mechanical meters
number of digits 7 (7.0 digits)
digit height 4 mm
digit width 1.2 mm
LED test 8 Imp/kWh
(option)
2 meters for active/reactive energy (kWh/kvarh) EWS1935

Current range xxxx/5 A (dip-switch setting)


nominal current IN 5A
max. current Imax 6A
consumption < 0.1 W/current path
start current 0.002 IN
(option) nominal current IN xxxx/1 A EWS1941xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied
Technical data
approbations
active energy EN 61036 class 1
construction polycarbonate housing acc. to UL 94 V-0
option EWS5945xxxx colour RAL 7035
equally load phases dimensions (mm) 106 x 90 x 58
weight 0.3 kg
mounting DIN rail acc. to DIN EN 50022
ambient temperature operation -10 °C to +60 °C
storage -40 °C to +70 °C
protection class 2

setting of the 4-pole dip switch

deviating primary currents are programmed at works


according to the details of the order.

www.mbs-ag.com 313
MBS AG

EWS1995
Three-phase energy transformer meter
AC energy transformer meter for clip-on to 35 mm DIN rail

Type of energy meter EWS1995xxxx


xxxx declaring the primary current is absolutely necessary

Mains 4-wire L-N (230 V)


rated voltage UN 57 V, 100 V, 230 V, 400 V
tolerance value -20 %...+20 %
photo is similar to the original consumption < 3.0 W/phase
frequency 50 Hz
frequency range 45...65 Hz

drawing Output 1 relay impulse output


relay 250 V, 6 A, 50 Hz
impulse duration 100 ms
max. load 1500 W
output impulse 1 Imp/kWh
max. impulse 4000/h
(option) EWS1195xxxx
optocoupler 40 V / 27 mA max.
(S0) impulse duration 100 ms +/-50 %
collector open output impulse 1 Imp/Wh (30...250 A)
output impulse 10 Imp/Wh (300...2000 A)
impedance 100 Ohm

Counter LCD counter meter for active energy import/export (kWh)


diagram
LCD counter meter
number of digits 2x9 (9.0 digits)
digit height 4.86 mm
digit width 2.96 mm
(option)
LCD counter meters for active/reactive energy (kWh/kvarh) EEH1985

Current range xxxx/5 A (dip-switch setting)


nominal current IN 5A
max. current Imax 6A
consumption < 0.1 W/current path
start current 0.002 IN
(option) nominal current IN xxxx/1 A EWS1991xxxx

Primary current 0.5 A to 2000 A


If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied
Technical data
approbations
active energy EN 61036 class 1
construction polycarbonate housing acc. to UL 94 V-0
colour RAL 7035
option EWS5995xxxx dimensions (mm) 106 x 90 x 58
equally load phases weight 0.3 kg
mounting DIN rail acc. to DIN EN 50022
ambient temperature operation -10 °C to +60 °C
storage -40 °C to +70 °C
protection class 2

setting of the 4-pole dip switch

deviating primary currents are programmed at works


according to the details of the order.