COOLING TOWER WATER TREATMENT CHEMICALS

To,
M/S. Atulya IT Park.
in Front of India coffee house ,Khandwa Road,
Indore (M.P.)
Ph No.97544 97433
E-mail: mep.itparkindore@gmail.com

ROYAL CHEMICALS,
49,SHESHADRI COLONY NEAR MARIMATA POLICE PETROL PUMP INDORE(M.P.)452 006
Phone No.0731-2455353,9302253053,9300535353,9300435353
E-mail Id:- troyalchemicals@gmail.com, troyalchemicals@yahoo.com
ROYAL CHEMICALS
Everything in Water Treatment

Ref: RC/ AIP/156/MP/19-20 July, 11, 2019


To,
M/S. Atulya IT Park.
in Front of India coffee house ,Khandwa Road,
Indore (M.P.)
Ph No.97544 97433
E-mail: mep.itparkindore@gmail.com

Kind Attn. Mr.Madan Mohan Tiwari

Sub: Offer for cooling tower System-Reg:

Dear Sir,
We refer to the visit of our Ravi Thakur along with Ashish pandey, regarding the above mentioned
subject. We thank you very much for the interest shown on our products.

As per the discussion we are pleased to introduce ourselves as one of the fast-growing dealer of
M/S. Watech chemicals Pvt. Ltd. Chennai who is the leading manufacturer of wide range of
chemicals for various water, effluent & process treatment applications. We are handling more than
600 customers in and all over India covering major industries, hospitals, educational institutes,
government dairy and other major projects. The company is promoted and managed by a team of
techno commercial experts with a combined experience of over 30 years in industrial water
treatment and management.
The company manufactures the following top-quality products and solutions as given below:

 Raw Water Treatment Chemicals


 Boiler Water Treatment Chemicals
 Cooling Water Treatment Chemicals
 Chilling Water Treatment Chemicals
 Process Chemicals-Paper, Sugar & Textile
 Polyelectrolyte / Flocculants
 Effluent Treatment Chemicals
 R.O. Membrane Treatment Chemicals
 Fuel Additives / Fire Side Chemicals
 Decolourants For Effluents
 De-scaling Chemicals
 Evaporator Anti Scalant
 Package Treatment
OBJECTIVE

Our objective is to provide total industrial water treatment needs such as chemical solutions for boilers,
cooling water systems, RO membrane, effluent treatment & Process applications with wide range of
products at an affordable cost with complete customer satisfaction in every stage of our operation.

MISSION

Our mission is to provide quality products with complete customer satisfaction. We will achieve this mission
by constant improvement in quality and technology along with customer support.

QUALITY

Royal Chemicals that the customer should obtain the value for the money spend. On that basis quality
control department with elite professionals ensures the quality starting from raw material to the finished
product with the latest technology and ecofriendly operations.

TECHNICAL SERVICE

Royal Chemicals Believes that the success of any treatment programme depends majorly on the effective
after sales service. This can be provided by ROYAL CHEMICALS Service network at every stage of the
business operation to ensure and maintain the trouble free operation and breakdown hurdles.

SAFETY HEALTH & ENVIRONMENT

ROYAL CHEMICALS practice SHE in stage of the operation by strict monitoring and control. The
Company’s policy is such that it meets all the rules and regulations and guidelines to ensure safety to the
environment internally & externally. ROYAL CHEMICALS believe in eco friendly operations will be the
future.

VISION

ROYAL CHEMICALS believe strongly that anything related to water applications will be trouble shooting and solution
will be provided. We trust the above enables Watech to be the leader on its own way adding trust ability and
providing the best choice. At this juncture we eagerly awaiting for an opportunity to join hands with you to have long
standing relationship to serve you in the best way-“Your Partner for Water Solutions”- now and in the future.

As per your instruction we here with enclosed our offer for your cooling tower to prevent scale, corrosion
and to inhibit biological contaminations such as algae , funge and other bacteria’s t for your kind reference .
We have also enclosed a presentation on water treatment as informed to you which will give fair idea of the
important of the chemicals treatment.

We hope that the enclosed offer is up to your expectation and now we look forward to serve you.

Thanking you and assuring you our best & personalized services at all times,

Yours faithfully,

For: ROYAL CHEMICALS

(RAJESH GUPTA)
(Encl :Commercial and Technical Offer For Cooling Tower Water Treatment Chemicals, & Prducts
Catlogue )
 System Details For Cooling tower Plant :

Sr. No. No. of Cooling Towers Two (inter connected)


1. Type of Cooling Systems FRP
2. Holding tank capacity 04KL
3. Quality of Make-up Water AKVN Water
4. Make up / Day 4.0KL
5. Working Hours 24 Hrs.
6. Problem encountered Scale, corrosion and biological growth

 Chemicals Recommended:
Based on study of your system, we are pleased to recommend the dosage of the chemicals for the
Cooling Tower as under:

CHEMICALS DOSING PROGRAM

Sr. No Products Daily Dose Weekly Dose Application


1. R.C.-2100 0.750 Kgs Nil Corrosion Inhibitor
2. R.C.-2301 0.750 Kgs Nil De-Alkalizer
3. R.C.-2201 Nil 3.500Kgs oxidizing biocide
4. R.C.-2204 Nil 3.500Kgs Non- oxidizing biocide
Note:- RC-2201 & RC-2204 to be dosed Alternative week after sun set.
(Working days – 30 days)

Sr. no Products Consumption Ordering Qty. Price/kg Cost / Month


for per month
1. R.C.-2100 22.500Kgs. 50 Kgs. Rs:-110.00 Rs:-2475.00
2. R.C.-2301 22.500Kgs. 50 Kgs. Rs:-100.00 Rs:-2250.00
3. R.C.-2201 7.000Kgs. 50 Kgs. Rs:-120.00 Rs:-840.00
4. R.C.-2204 7.000Kgs. 50 Kgs. Rs:-130.00 Rs:-910.00
Total Cost per month.Rs.6500.00 (Aprox)

By adopting the above chemical treatment the life span of your pipelines and Heat-Exchangers will be
enhanced: Hence the replacement cost can be minimized or avoided which will lead to cost saving in
material and labour. Frequent De-Scaling of your system with acid will reduce the life of your costly
equipment. With our Chemical Treatment programme you can reduce the above cleaning. When water
supply is scarce and restricted it is not practically possible to clean the cooling tower frequently. With our
chemical treatment you can conserve the water and utilize it effectively which will leads to further cost
saving in material & labour. Plant shutdown/breakdown for mechanical/manual can be avoided.
ROYAL CHEMICALS
Everything in Water Treatment

Ref: RC/ AIP/156/MP/19-20 July, 11, 2019


To,
M/S. Atulya IT Park.
in Front of India coffee house ,Khandwa Road,
Indore (M.P.)
Ph No.97544 97433
E-mail: mep.itparkindore@gmail.com

Kind Attn. Mr.Madan Mohan Tiwari

Subject: Quotation and Business Terms:


Sr. No. Product Application Rate Kg. Std. Packing

1. R.C.2100 Anti Scalent (Cooling Tower Chemical) Rs.110.00 35 & 50 Kgs carboys.
2. R.C.2301 De- Alkalizer (Cooling Tower Chemical) Rs.100.00 35 & 50 Kgs carboys
3. R.C.2201 Oxidizing biocide (Cooling Tower Chemical) Rs.120.00 35 & 50 Kgs carboys
4. R.C.2204 Non Oxidizing biocide (Cooling Tower Chemical) Rs.130.00 35 & 50 Kgs carboys

BUSINESS TERMS.

1. Our GST No. : 23AFHPG6231M1ZI


2. Delivery : Within 10 days after confirm order.
3. Quotation validity : One month.
4. GST : 18% Extra or as applicable
5. Packing Charges : Rs. 5/- Per Kg. Extra at your cost./Empty Carboys returnable
6. Payment Terms : Against Delivery
7. Transportation : To pay basis.

A. Our service executive will visit in your plant once in a month.


B. Our service executive will analysis all required parameters and record Data
C. Chemical dosing will be increase & decrease depends of our water Analysis report & your
make-up water Quality and quantity.

We hope above mentioned quotation is in line with your requirement and we look forward valuable
reply. If you need any further information kindly do contact us.
We remain,
For: ROYAL CHEMICALS,

(RAJESH GUPTA)
Enclosed Product catlogs,
R.C.2100
ANTI SCALANT AND ANTIFOULANT
PRODUCT DESCRIPTION AND USE

R.C.-2100 is an all-organic blend of anti scalant and polymeric dispersants to provide excellent control
over mineral foulants in industrial evaporative cooling water systems. Besides preventing scale formation
and deposition, it also helps remove existing scales, when used under specified conditions. It exhibits
excellent control over iron fouling. When used along with corrosion inhibitors from the R.C.-2100 series
like R.C.-2100, it affords excellent synergy for total control over corrosion; scaling and non-biological
fouling Water treated with R.C.-2100 is safe to discharge in effluent without any pollution problems.

GENERAL SPECIFICATIONS
Appearance : Clear liquid
Wt./ml : 1.05 – 1.20
pH (as is) : Acidic
Solubility : Soluble in water

APPLICATION AND DOSAG

R.C.-2100 exhibits ant scaling properties by threshold inhibition, crystal distortion and sequestration.
The effective dose level depends on various factors like hardness, pH, temperature, fouling potential,
other inhibitors used And system specifics. It is recommended. For use up to 800-ppm total hardness (as
CaCO3) in the system for best results A feed level of 50 to 200 ppm should suffice in most cases. R.C.
Representative will help you select the most optimum dosage for your system. It is non-toxic and non-
polluting at use levels. R.C.-2100 must be fed continuously to ensure that recommended levels of
residuals are maintained at all times. The product can be fed neat from the container or with dosing
equipment using non-corrosive components like PP, PE, PVC or Teflon. Our field experts will help you
in designing suitable dosing arrangement for your system

HANDLING AND STORAGE

Avoid contact with eyes and prolonged contact with skin. Do not take internally. In case of contact with
eyes, flush with ample water and get prompt medical attention. Gloves and goggles should be used where
appropriate. R.C.-2100 containers should be stored airtight under shade and away from direct sunlight.

PACKING

Available in 35, 50 kgs Carboys.


WA-TECH CHEMICALS PVT.LTD.
12/143,JJ NAGAR, MOGAPPAIR EAST, CHENNAI

AUTHORIZED DEALER FOR MP, RAJASTHAN, GUJRAT, MAHARASHTRA, DELHI, U.P.,


PUNJAB, HARIYANA, and H.P. & U.K.

ROYAL CHEMICALS ®,49 SHESHADRI COLONY NEAR POLICE PETROL


PUMP INDORE (MP) Mob: 9300535353, TEL: 0731-2455353
R.C. 2301
DE-ALKALISER

PRODUCT DESCRIPTION AND USE


R.C.-2301 provides positive alkalinity control to open recalculating systems while avoiding the hazards
associate with the handling of strong liquid acids. R.C.-2301 is a highly soluble liquid and can be dosed
continuously or intermittently as required .It exhibits excellent control over alkalinity. When used along
with corrosion inhibitors from the series like R.C.-2301, it affords excellent synergy for total control over
corrosion; scaling and non-biological fouling Water treated with R.C. -2301 is safe to discharge in
effluent without any pollution problems.
GENERAL SPECIFICATIONS
Appearance : Brown liquid
Wt./ml : 1.1 – 1.20
pH (as is) : Acidic
Solubility : Soluble in water
APPLICATION AND DOSAGE
R.C.-2301 Exhibits good alkalinity control and pH stabilization. The effective dose level depends on
various factors like pH, temperature, fouling potential, other inhibitors used and system specifics. It is
recommended. Approximately 25-100 ppm of R.C.-2301 is required for each part of alkalinity to be
neutralized in the makeup water. R.C. -2301 should be dosed in the cooling tower sump by dripping
R.C.-2301 representative will help you to select the most optimum dosage for your system. It is non-
toxic and non-polluting at use levels. R.C.-2301 must be fed continuously to ensure that recommended
levels of pH maintained at all times. The product can be fed neat from the container or with dosing
equipment using non-corrosive components like PP, PE, PVC or Teflon. Our field parts will help you in
designing suitable dosing arrangement for your system.
HANDLING AND STORAGE
Avoid contact with eyes and prolonged contact with skin. Do not take internally. In case of contact with
eyes, flush with plenty of water and get prompt medical attention. Gloves and goggles should be used
where appropriate. R.C.-2301 containers should be stored airtight under shade and away from direct
sunlight.
PACKING
Available in 35 & 50 kgs Carboys.

MFG:- WA-TECH CHEMICALS PVT.LTD.


12/143,JJ NAGAR, MOGAPPAIR EAST,

AUTHORIZED DEALER FOR MP, RAJASTHAN, GUJRAT, MAHARASHTRA, DELHI, U.P.,


PUNJAB, HARIYANA & H.P. & U.K.
R.C.2201
OXYDIGING BIOCIDE
DESCRIPTION AND USE

R.C.-2201 is a strong oxidizing biocide and is an extremely effective biocide for the control of bacteria,
fungi and algae in aqueous systems. It has been found to be particularly effective against nitrifying
bacteria, iron bacteria and anaerobic Sulphate reducing bacteria.

GENERAL SPECIFICATIONS

Appearance : Clear pale yellow liquid


Wt/ml. : 1.1  0.05
pH (as is) : Alkaline
Solubility : Soluble in water
APPLICATIONS
R.C.-2201 can be advantageously used to control microbiological fouling in industrial cooling water
systems and process water of a number of industrial systems and materials subjected to deterioration by
microbiological action. Paper mill water system, oil well brines, drilling mud, paints, latex emulsions,
coating materials are amongst the various applications where microbiological activity could be controlled
by R.C.-2201The amount of R.C.-2201 required would depend on the type of systems, the nature and the
extent of microbiological contamination and the degree of control required. RC representative shall
advice the actual dose requirement for individual system.
FEEDING

R.C.-2201 can be directly fed from the container into the basin of the cooling water system or at any
other point where good mixing can be assured. No special feeding equipment is required.
HANDLING AND SAFETY
R.C.-2201 should be handled like any other industrial chemicals such as acid, alkali etc. The product
should be stored in cool, dry places away from direct sunlight, sources of moisture, heat etc. Protective
gears like goggles, gloves, safety shoes must be worn while handling the product. Avoid direct contact
with skin. In case of accidental splash, wash the affected part with plenty of fresh water and get
immediate medical attention.
ENVIRONMENTAL SAFETY
R.C.-2201 (S)Is non-toxic and non-polluting at suggested dose levels. The constituents of R.C.-2201 are
completely biodegradable and can be safely discharged into any waste stream.
PACKING
Available in 35 & 50 kgs Carboys.

MFG:- WA-TECH CHEMICALS PVT.LTD.


12/143,JJ NAGAR, MOGAPPAIR EAST,

AUTHORIZED DEALER FOR MP, RAJASTHAN, GUJRAT, MAHARASTRA, DELHI, U.P.,


PUNJAB,HARIYANA AND H.P. & U.K.
R.C. 2204
NON-OXYDIGING BIOCIDE
DESCRIPTION AND USE
R.C.-2204 is a highly active non-oxidizing Micro biocide for effective control of bacteria, fungi and algae in
industrial evaporative cooling water systems. It is also singularly effective against Sulphate reducing bacteria. Use
of R.C.-2204 also arrests the growth of nitrifying bacteria responsible for drop in pH of circulating water
contaminated with ammonia. The product under use level conditions gets consumed and degraded to non-toxic
elements and also gets stripped in the cooling tower, causing no harm to the environmental.
GENERAL SPECIFICATIONS

Appearance : Slightly hazy yellow liquid


Wt./ml : 0.9 to 1.0
pH : Alkaline
Solubility : Soluble in water
APPLICATION AND DOSAGE

The product is to be dosed neat in the cooling tower sump at a point where thorough mixing can be ensured. While
dosing the product care should be taken to shut the blow down and ensure a minimum contact time of about 8-12
hrs. For best results, It is advisable to give blow down after this contact time to remove the dead biomass from the
system. Effective dosage varies with system demand. Badly fouled systems will need higher dosage or precleaning.
Our representative will assist in selecting the right dose and frequency of addition for your plant. The product is not
recommended in potable water system. Other applications include paper mill water system, oil well brines, drilling
fluids, paints, latex emulsions and other similar areas where microbial problems are acute.
FEEDING
R.C.-2204 can be directly fed from the container into the basin of the cooling water system or at any other point
where good mixing can be ensured. No special feeding equipment is required.
HANDLING
R.C.-2204 may cause skin and eye irritation. It is harmful if taken internally. In case of contact, flush the affected
area with plenty of water. In case of prolonged contact, flush with plenty of water and get prompt medical attention.
In case of ingestion, induce vomiting by administering warm salt water or any other emetic and get medical
attention. Contaminated clothing should be thoroughly washed before reuse. Use of protective rubber gloves is
recommended during handling of R.C.-2204.
ENVIRONMENTAL SAFETY
R.C.-2204 is toxic to fish. Do not use in potable water systems or where contamination of potable water can occur.
In cooling water systems, R.C.-2204 is slowly hydrolyzed to non-toxic products. Most of these products are
volatile and are stripped off from the system, thus posing no effluent problems.
PACKING
Available in 35 & 50 kgs Carboys.

MFG:- WA-TECH CHEMICALS PVT.LTD.


12/143,JJ NAGAR, MOGAPPAIR EAST,

AUTHORIZED DEALER FOR MP, RAJASTHAN ,GUJRAT,U.P.,PUNJAB,H.P.


DELHI,U.K.,MAHARASHTRA,DELHI,HARIYANA.
1. VENDOR ADDRESS DETAILS

a) Name of the company (Registered/Head office) ROYAL CHEMICALS,

Name of Proprietor as per PAN allotted RAJESH GUPTA


b) Address 1 :- 49,SHESHADRI COLONY NEAR
MARIMATA POLICE PETROL PUMP
City :- INDORE
Pin Code :- 452 006
State :- M.P.
c) Phone (with code) MO NO.91-9300535353, 98262-53530 //
PH NO. 0731-2455353
d) Fax (with code) N.A.
e) E – mail Id troyalchemicals@yahoo.com /
troyalchemicals@gmail.com
f) Website www.royalchemicals.in
g) Type of industry Dealer
h) Payment Term Immediate
2. CONTACT PERSON DETAILS

a) Name RAJESH GUPTA


b) Designation PROPRIETER
c) Contact Number i) 91-9300535353,
ii) 91-9300435353
d) E-mail Id troyalchemicals@yahoo.com / troyalchemicals@gmail.com
e) Website www.royalchemicals.in
3. STATUTORY REGISTRATION DETAILS

a) Service Tax Registration No. N.A.


b) Service Tax Jurisdiction N.A.
c) VAT No (if applicable)
( 11 Digit Only) 23600201056 TIN NO.
d) Central Sales Tax Registration No. 0102/xxI/0725/c
DT.25-02-1995

e) GST NO. 23AFHPG6231M1ZI


f) Excise Range N.A.
g) Excise Division N.A.
h) Excise Commisonerate N.A.
k) PAN No AFHPG6231M
l) TDS certificate, wherever TDS certificate will be send via email ( Digital
deducted shall be issued on annual signature) provide email id below this line
basis./ quarterly basis
Email ID
4. BANKER DETAILS

Bank Name State Bank of India


Branch Mahesh Nagar , Rajmohalla, Indore (MP)
Current Account Number 63026944736
IFS CODE SBIN0030131