Professional Documents
Culture Documents
NORAC Innhold Edition8 2015 Web Wall Panel
NORAC Innhold Edition8 2015 Web Wall Panel
INTERIOR
SYSTEMS
PRODUCT MANUAL
NORAC AS is the world’s leading manufacturer
and supplier of marine interior systems.
©
E D IT I ON 8
WWW.NORAC.NO
0575
MARINE
INTERIOR MANUFACTURER
SYSTEMS & SUPPLIER OF MARINE
INTERIOR SYSTEMS
Norac is a leading supplier of interior systems for cruise ships,
ferries, commercial vessels and offshore installations. Headquartered
in Norway, the company manufactures and distributes fire-rated walls,
ceiling systems, doors, prefabricated wet units, floating floors,
windows and furniture, making Norac a “one-stop shop” for
high-quality, afford-able interior systems for the maritime industry.
Norac products are manufactured with only first-class materials
in compliance with the most exacting rules and regulations and Norac’s
own strict quality control measures.
Wall Systems
Norac designs wall systems designed to meet
the following criteria: quality, flexibility, fire,
sound, weight and ease of installation. Based
on new requirements for improved acoustic
insulation, Norac has developed a series of
acoustic walls, which offer documented sound
reduction properties of up to 54 dB RW.
Ceiling Systems
Norac manufactures and supplies both
suspended and self suspended ceiling
solutions. The ceiling systems are recognized
throughout the industry for both their superior
acoustic properties and ease of installation.
The self-suspended ceiling modules have
been designed to avoid structural borne noise
and to reduce safety risks associated with
loose fire insulation.
Doors
We offer B-rated doors.
Floating Floors
Norac manufactures and supplies floating floor
systems designed for strength, safety, ease of
installation and sound reduction properties.
The floor system is constructed of galvanized
steel cassettes of 3 mm thickness, but is easy
to transport and install.
Furniture
Norac can offer a flexible line of ship’s
furniture for conventional ships and offshore
living quarters.
2
External walls
Norac is manufacturing specialized internal
and external firewalls on behalf of and in
co-operation with BD Systems, U.K. BD Sys-
tems has developed a comprehensive range
of fire/acoustic rated Internal Panelling and
External Cladding systems for the
outfitting and construction of accommodation
units and production/drilling areasThese cover
the full range of “C”, “B”, “A” and “H” class
systems. They have been developed for high
performance and durability in the harshest
of offshore environments.
Wet Units
Building on decades of experience and
specialized competence, Norac offers fully
fitted wet units. The Norac modular wet units
are ideal for marine accommodations from
cruise ships to offshore installations.
3
WWW.NORAC.NO
0575
HISTORY
MARINE Our Company was established in a fast increasing Norwegian Oil- and
Offshore Market. Our founder, Fred Olsen & Co, was an initiator for the
INTERIOR construction of semisubmersible drilling rigs and built offshore instal-
SYSTEMS lations at Aker Vindholmen Ship Yard in Arendal, Norway. The need of
fireproof panels cleared the path for establishing a factory for produc-
tion of marine interior wall panels – Aker Panels.
Aker Panel was established in 1973 Since 1978 Arne Borg has been working in for commercial vessels and offshore installa-
and made the products and the brand the company, and since 1987 as the managing tions, and through the years Arne Borg became
name “Aker Panel” well known in the director of Aker Panel. In 1982 the company internationally known as Mr. NORAC.
fast growing Norwegian offshore expanded under the new name Norwegian
market. Since the early 1970ies our Accomodation Systems – NORAC. At that For years, NORAC has delivered accommo-
panel systems were recognized as time our products were introduced to the dation systems to offshore installations on the
“Aker Panel”, and by some it still is. international market as NORAC Marine Interior Norwegian Continental Shelf, in compliance
Systems. In a few years NORAC became a well with the most exacting rules and regulations
recognized manufacturer of interior systems from Norwegian authorities, known among
the world’s strictest classification societies.
This fact together with NORAC’s own strict
quality control measures brought NORAC to a
leading position in an increasingly demanding
international oil- and offshore market.
Left
ARNE BORG
Managing Director
(1987-2014)
Below
THE FIRST
CONDEEP
DELIVERED
AKER VINDHOLMEN
The first Aker Panels were manufactured
at Aker Vindholmen Ship Yard, but later the
factory was re-established in an industrial
area outside the City Centre of Arendal.
4
Since the early 1990ies NORAC became the In 2001, Norac established Norac Suzhou in BUILDING DOCK
largest supplier of Marine Interior Systems China. The aim was to cover the Asian market. MEYER WERFT
for cruise and ferries, and the Company has
through the years supplied accommodation When Norac established its fully-owned Norac’s long lasting co-operation with Meyer
materials to more than 8000 ships worldwide. subsidiary UAB Norac in Lithuania in 2006, Werft in Germany is very much thanks to our
efficiency and logistics in supplying high
the business quickly grew into an efficient quality products on time. Photo: Meyer Werft
In 1991 we had our first large delivery of walls production company, which currently has
and ceilings to the Meyer Werft in Germany. approx. 400 employees.
This was the introduction to a long lasting
co-operation very much thanks to our In 2015 NORAC moves the remainder of
efficiency and logistics in supplying high production in Arendal to Lithuania, and
quality parts and products on time. Especially strengthens its administration and sales
this is a demand from customers working organization in Arendal. Norac takes steps to
at principles of lean manufacturing. NORAC reinforce competitive ability in a challenging
Marine Interior Systems is recognized as a and demanding market.
preferred supplier who keeps its promises –
always. Today, NORAC is a leading supplier of interior
systems for cruise ships, ferries, commercial
NORAC walls and ceilings have always been vessels and offshore installations.
manufactured using first-class materials, steel Headquartered in Norway, the company
and rock wool, in compliance with the strictest manufactures and distributes fire-rated walls,
regulations of the Petroleum Safety Authority, ceiling systems, doors, prefabricated wet units,
which are atop of the hierarchy of regulations floating floors and furniture, making NORAC
and refers to numerous underlying standards, a one-stop shop for high-quality, affordable
among them NORSOK. interior systems for the maritime industry.
Since 1995 NORAC offers turnkey deliveries NORAC’s present directing manager, Rune
of complete interior systems including floating Aarrestad, took over as Arne Borg’s, inheritor,
floors, wet units, carpets, furniture – even and he is keeping the Company on a steady
cutlery and sets if wanted. On demand, course into the future.
NORAC can build up complete mockups of SCANDINAVIAN STAR
corridors, meeting rooms, suites, cabins, wet In 2015 NORAC has expanded into other
units and even complete cabins including industrial areas, but our core business is still Norway’s Titanic: The “Scandinavian Star”
bathroom and furniture. Marine Interior Systems. disaster in 1990 was one of the worst
maritime disasters in Baltic waters, at least
excluding incidents during the world wars.
Photo: NRK
5
WWW.NORAC.NO
0575
6
WWW.NORAC.NO
0575
CONTENTS
WALLS CEILINGS WET UNITS
NOTE:
7
WWW.NORAC.NO
0575
WALLS
CONTENTS
K-600 9 Cable Ducting 21 C.I.S. Panels 34
Q-600 / CF-600 11 Panels for wet spaces 23 Light Weight Omega 36
C-600 / CS-600 13 Wet coaming 23 Heavy Duty A60 38
CSG-600/70 15 Inspection Door and Hatches 24 Heavy Duty H120 40
Additional panel concept 16 Window-boxes 27 Heavy Duty Omega 42
Removable panels 17 Example of standard system 28 Clearspan™ H60 44
Reinforcements 18 Example of modular system 29 Blast Walls Joint Details 46
Horizonal Joint 19 Profiles 30 Fastclad Refurnishing Panels 47
Loadbearing Capacity 20
8
WALLS
K-600
K-600 is designed with integrated joint profiles
for rapid installation, leaving a flush surface
with single seam joints. Available in standard
or modular system.
Weight
All weights are based on system weight,
including all profiles.
20 100 mm
mm
K-600/25mm/B-15 K-600/2x25mm/A-60
K-600/50mm/B-15
A-585/50mm/B-15
A-585/25mm/B-15
* Alu/Steel **Alu/Alu
9
WWW.NORAC.NO
0575
WALLS
K // CONNECTING DETAILS
Complete corner element for cut finish or flush. Rounded corners. T-connection.
Standard U-profile for flush finish. Complete corner element for exposed corners only. Recess connection for improved flexibility.
NOTE:
10
WWW.NORAC.NO
0575
WALLS
Q-600
/ CF-600
Q-600 is an acoustic wall system
of sandwich construction with an exellent
sound reduction quality.
Weight
All weights are based on system weight,
including all profiles.
Q-600/50, 46 dB
11
WWW.NORAC.NO
0575
WALLS
Q / CF // CONNECTING DETAILS
NOTE:
12
WWW.NORAC.NO
0575
WALLS
C-600
/ CS-600
C-600 is an acoustic double wall system with
two independent wall elements installed in the
same profile system.
Weight
All weights are based on system weight,
including all profiles.
60
50
Sound insulation (dB)
40
30
20 Sound insulation
45 dB
10
0
100 160 250 400 630 1000 1600 2500
Frequency (Hz)
13
WWW.NORAC.NO
0575
WALLS
C // CONNECTING DETAILS
Separation profile
to keep walls apart.
NOTE:
14
WWW.NORAC.NO
0575
WALLS
CSG-600
/ 70
The use of additional insulation between the
two panels of a CS-600/70 wall improves the
sound reduction by an amazing 4dB compared
to CS system on page 15.
Weight
All weights are based on system weight,
including all profiles.
Description CSG-600 / 50
Fire class B-15 / B-30
Standard width 600 mm
Module length up to 3000 mm
53 dB Partition only
Module width 600 mm
Thickness 70 mm
Weight 34.4 kg/m²
Sound reduction Rw=53 dB
Adjusted References Sound Reduction Index
Thermal isolation U=0.47 W/m² K (Laboratory measurement)
Application Partition
15
WWW.NORAC.NO
0575
WALLS
ADDITIONAL PANEL CONCEPT
Additional panel concept for installation on
existing walls. Ideal for refurbishing purposes,
and where a better sound reduction between
cabins is required. Thickness 20 mm only.
Weight
All weights are based on system weight,
including all profiles.
Description C-600 / 20
Fire class C-class
Standard width 600 mm
Module length up to 3000 mm
Module width 600 mm
Thickness 20 mm
Weight 12.4 kg/m²
Sound reduction* 42 up to 51 dB
Thermal isolation**
Application Lining
16
WWW.NORAC.NO
0575
WALLS
REMOVABLE PANELS
To be used where access is required.
C-class.
50mm
25mm
17
WWW.NORAC.NO
0575
WALLS
REINFORCEMENT
Built in reinforcements to accommodate heavy
wall hung equipment, such as wash basins,
TV-brackets, pullman beds etc. can be deliv-
ered upon request. Various solutions available.
Single type.
Double type.
18
WWW.NORAC.NO
0575
WALLS
HORIZONTAL JOINT
For areas where ceiling height exceeds
3000 mm. Used for linings only.
Conncetion to steel
bulkhead is yard’s supply.
19
WWW.NORAC.NO
0575
WALLS
LOADBEARING CAPACITY
Strength of hand rails attached Both K-600/25 mm and K-600/50 mm are
to wall panels qualified according to the SOLAS regulation:
The tongue and groove system allow fixing
of heavy objects to the wall without special “Strength test for B-class panels to which
reinforcement. handrails are attached on RO-RO passenger
ships”.
20
WWW.NORAC.NO
0575
WALLS
CABLE DUCTING
Pre-arranged duct and cut-outs for cables
and sockets can be delivered upon request.
Tested with up to 10 ducts per 600 mm panel
as B-15 class.
Perforated top
Standard size of conduit: profile option.
Single 20x30 mm
Double 20x60 mm
21
WWW.NORAC.NO
0575
WALLS
PANELS FOR WET SPACES
Detail for wet room - 25mm lining only. 50mm panels with symmetric finish. 50mm panels with asymmetric finish.
8mm
15mm
Height
according to
request
22
WWW.NORAC.NO
0575
WALLS
WET COAMING
Coaming for 25mm wet panel. Coaming for 50mm panels wet / wet. Coaming for 50mm panels wet / dry.
23
WWW.NORAC.NO
0575
WALLS
INSPECTION DOORS AND HATCHES
For quick access to technical spaces such as
pipe connection, electrical boxes etc.
Inspection Hatch. Max size: 500x1500mm. B-15. Inspection Door. Max size: 900x1850mm for B-15 class. Split inspection door. Delivered as one piece.
24
WWW.NORAC.NO
0575
WALLS
INSPECT. DOOR // TECHNICAL DETAILS
Inspection door Section A -A
front view
21
A
20
TRESHOLD VERTICAL OPENING TOP ELEMENT
43 CLEAR OPENING 43
B B
TOTAL WIDTH = CLEAR OPENING + 86mm
25
WWW.NORAC.NO
0575
WALLS
INSPECT. HATCH // TECHNICAL DETAILS
Inspection hatch front view A
TOTAL HEIGHT
B B
TOTAL WIDTH
Section A - A
CUT OUT = C/O + 40mm
50mm Wall
25mm Wall
50 CLEAR OPENING 50
26
WWW.NORAC.NO
0575
WALLS
WINDOW-BOXES
Window boxes are made from 1.25 mm
galvanized steel plates and painted in required
colour. Dimensions according to customers
demand. Other solutions can be made
according to customers specification.
50,00
50,00
3,40
27
WWW.NORAC.NO
0575
WALLS
EXAMPLE OF STANDARD SYSTEM
A standard system is a flexible system
allowing adjustments onboard the vessel
during construction. The panels are delivered
in one standard size and are cut to fit
according to the on site measurements
with use of standard profiles.
B A
28
WWW.NORAC.NO
0575
WALLS
EXAMPLE OF MODULAR SYSTEM
A modular system is a fully tailor-made system
to avoid adjustments and cutting onboard
vessels. These systems reduce the installation
time for the yard and more importantly reduces
costs.
A.1
A.2
B
B
29
WWW.NORAC.NO
0575
WALLS
PROFILES
Horizontal Joint
For areas where ceiling height exceeds
3000 mm. Used for linings only.
No: 650401/650411
Floor profile for visible use.
PVC coated galv. steel sheet.
For 25 mm panel: 625411 (or: 625401).
No: 650352/650353
Standard galvanized top profile for suspen-
sion.
Also available with brackets for welding.
For 25 mm panel: 625353(or: 625352).
No: 650010
Adjustment-profile for flush start.
PVC coated galv. steel sheet.
For 25 mm: 625010.
30
WWW.NORAC.NO
0575
WALLS
PROFILES
Stuffed with loose insulation (yard supply).
No: 020
Finish with two profiles against crossing wall.
Also used as start with two-coloured wall.
PVC coated galv. steel sheet.
No: 650032
Adjustment profile for start/stop.
PVC coated galv. steel sheet.
No: 8’’xx’’
Ex: xx = 45˚ = 650845
Bent adjustment starting profile.
Remove full stop each 5 degrees from 5 to 60˚.
No: 4’’xxx’’
Bent T-connection with two prof. for stop
against crossing wall. Also used as start
with two-coloured wall.
31
WWW.NORAC.NO
0575
WALLS
PROFILES
No: 3’’xxx’’
Bent profiles for changing of wall direction.
Remove full stop each 5 degrees from 30 to
305˚.
No: 650074
Wide joint-profile for change from 50 mm to
25 mm panel. Delivered with separate channel
for fastening during installation.
No: 650074
Wide joint-profile for change from 50 mm to
25 mm panel. Delivered with separate channel
for fastening during installation.
32
WWW.NORAC.NO
0575
WALLS
PROFILES
No: 6506’’xx’’
Ex: xx = 45˚ = 650645.
Bent joint profile for connection of cut panels,
when wall direction changes.
Remove full stop each 5 degrees from 5 to 85˚.
For 25 mm panel: 6256’’xx’’.
(Optional)
No: 6507’’xx’’
Ex: xx = 45˚ = 650745.
Same as above, but for flush
surface finish.
(Optional)
33
WWW.NORAC.NO
0575
WALLS - INTERNAL ACOUSTIC
C.I.S PANELS
Standing for “Clip In System”. It is the ease
and speed with which the CIS panel systems
are installed and demounted that makes this
system the most popular and widely used
system in the market place today. All panels
within the CIS range are rigid in strength and
extremely flexible in cutting and installing.
Available as a standard or fully modular
system.
Details
Non-load bearing composite firewalls for
the offshore and marine industries.
46 dB
34
WWW.NORAC.NO
0575
WALLS - INTERNAL ACOUSTIC
C.I.S 1 HOUR // CONNECTING DETAILS
Standard end
Standard corner (B30) (A30) Standard corner (A60) Standard radius corner
NOTE:
35
WWW.NORAC.NO
0575
WALLS - INTERNAL
LIGHT WEIGHT
OMEGA
Early developments in composite firewalls by
BD Systems utilised the “Omega” type joining
profile. This series of panels is always
popular where space saving and flexibility
of installation are important considerations.
Details
Non-load bearing lightweight A Class wall
lining and partition panels for the offshore
industry.
Joint insulation
A30 only
A30
20 x 30 conduit raceways
Description FO - 25 FO - 50
Fire class Non combustible A0 - A30 / 1 hour
Standard width 600 nominal 600 nominal
Panel height up to 3000 mm up to 4500 mm
Thickness 27 mm 52 mm
Weight 16.6 kg/m² 22.03 kg/m²
Sound reduction Rw=26 dB Rw=32 dB
Thermal isolation U=1.12 W/m² K U=0.61 W/m² K
Application Lining Partition*
36
WWW.NORAC.NO
0575
WALLS - INTERNAL
L.W. OMEGA // CONNECTING DETAILS
NOTE:
37
WWW.NORAC.NO
0575
WALLS - HEAVY DUTY
A60
A totally new and revolutionary concept in
composite panel manufacturing.
External
Non load-bearing stainless steel panels
will replace conventional heavy steel plate
cladding. No need for added insulation or
decorative liners.
Internal
Non load-bearing decorative panels will
replace conventional steel plate bulkheads
with added insulation and decorative liners.
Typically for use around Galley’s, Laundry’s
and Plant Rooms.
Description BD HD100
Fire class A60
Standard width 1200 mm
Module height up to 6000 mm
Module width 300 to 1200 mm
Thickness 100 mm
Weight 32 kg/m²
Sound reduction Rw=40 dB
Thermal isolation U=0.32 W/m² K
Application Cladding / Partition
38
WWW.NORAC.NO
0575
WALLS - HEAVY DUTY
A60 // CONNECTING DETAILS
NOTE:
39
WWW.NORAC.NO
0575
WALLS - HEAVY DUTY
H120
A totally new and revolutionary concept in
composite panel manufacturing.
External
Non load-bearing stainless steel panels
will replace conventional heavy steel plate
cladding. No need for added insulation or
decorative liners.
Internal
Non load-bearing decorative panels will
replace conventional steel plate bulkheads
with added insulation and decorative liners.
Typically for use around Galley’s, Laundry’s
and Plant Rooms.
Description BD HD2-150
Fire class H120 / 2 hour
Standard width 1180 mm
Panel height up to 6000 mm
Thickness 150 mm
Weight 61.5 kg/m²
Sound reduction Rw=50 dB
Thermal isolation U=0.22 W/m² K
Application Cladding / Partition
40
WWW.NORAC.NO
0575
WALLS - HEAVY DUTY
H120 // CONNECTING DETAILS
NOTE:
41
WWW.NORAC.NO
0575
WALLS - INTERNAL / EXTERNAL
HD OMEGA
Further development of the “Omega” concept
by BD has culminated in the certification of the
HD (Heavy Duty) range of products. A range
that covers all A and H Class firewall require-
ments for both Internal and External use.
Details
Encapsulated insulation and completely flat
surface eliminates the need for floor- levelling
screeds.
42
WWW.NORAC.NO
0575
WALLS
HD OMEGA // CONNECTING DETAILS
External roof & deck finished with suitable weather protection
43
WWW.NORAC.NO
0575
WALLS - CLEARSPAN™
H60
As a fully mechanically fixed structure
CLEARSPANTM is a unique Lightweight Blast
& Fire Wall System.
Details
• Fully mechanically fixed
• Lightweight
• Significant Blast Loadings can be
achieved without the need for additional
support structures.
• Cavity depth and panel thickness can be
adjusted to meet elevated Blast
requirements.
• Designed to incorporate BD Blast doors,
windows and penetrations.
44
WWW.NORAC.NO
0575
WALLS - CLEARSPAN™
H60 // CONNECTING DETAILS
45
WWW.NORAC.NO
0575
WALLS - BLAST
JOINT DETAILS
Detail of joint
46
WWW.NORAC.NO
0575
WALLS - FASTCLAD
REFURNISHING PANELS
FastClad is an extremely fast, clean, easy and
very cost effective means by which to refurbish
existing slightly old and tired looking wall
panel systems on board cruise ships or inside
offshore accommodation modules.
Description Panels
Fire class Class 1 or better
Standard width 600 mm
Module height up to 3000 mm
Module width 100 - 1200 mm
Thickness 0.7 mm
Weight 4.5 kg/m²
Sound reduction +2 dB on existing
Thermal isolation None
Application Decorative covering
47
WWW.NORAC.NO
0575
CEILINGS
CONTENTS
B-500 / 52 50 Component List 57
Inspection Hatch for B-500 Ceilings 51 Light boxes 65
B-600 / 40 52 Access Hatch 66
T-600 / 40 53
M-200 / 250 / 300 54
Tiles P-52 55
Tiles P-31 56
48
WWW.NORAC.NO
0575
CEILINGS
CEILINGS
B-500 / 52
B-500/52 is a self suspended ceiling of
sandwich construction and designed for easy
and rapid installation with no connecting
profiles.
Weight
All weights are based on system weight,
including all profiles.
T-joint profile
For rooms exceeding 3000 mm (also B-15). Approved B-15 with perforated surface.
50
WWW.NORAC.NO
0575
CEILINGS
INSPECTION HATCH FOR B-500
For quick access to technical spaces above
the ceiling such as ventilation, electrical
wiring etc. Surface is normally the same as the
ceiling to make a discreet finish.
Ceiling hatch.
51
WWW.NORAC.NO
0575
CEILINGS
B-600 / 40
B-600/40 is a self suspended ceiling of
sandwich construction and designed for easy
and rapid installation with no connecting
profiles.
Weight
All weights are based on system weight,
including all profiles.
T-joint profile
For rooms exceeding 3000 mm (also B-15). Approved B-15 with perforated surface.
Description B-600 / 40
Fire class B-15 / A-30
Panel length up to 2715 mm
Standard module width 300 / 600 mm
Special module width 100 - 700 mm
Thickness 40 mm
Weight 18.1 kg/m²
Sound reduction Rw=50 dB*
Thermal isolation U=0.66 W/m² K
Application Selv suspended ceiling
52
WWW.NORAC.NO
0575
CEILINGS
T-600 / 40 / 30
T-600/40 is a self suspended ceiling of
sandwich construction and designed for easy
and rapid installation with no connecting
profiles.
Weigth
All weights are based on system weight,
including all profiles.
T-joint profile
For rooms exceeding 3000 mm (also B-15). Approved B-15 with perforated surface. Only T-600 / 40.
* Sound reduction between cabins **Fire gasket (16 x 2mm) in the female joint
53
WWW.NORAC.NO
0575
CEILINGS
M-200 / 250 / 300
Ceiling can be fitted - and refitted as necessary
- swiftly and easily with the panels clipping
into a carrier system and then secured in place
by screws. Again, to facilitate access, each
individual panel can be easily removed.
Colours
Colour is obviously an essential element in
interior design, so although standard panels
are white, we can work with your designers to
meet almost any colour specification.
Add. insulation
Insulated ceiling
Cabin / room area
A-30 / A-60 ** A-15
Description M200 / M250 / M300
Fire class B-0 / A-15 B-15 / A-30 / A-60 **
Module width* 200 - 250 - 300 mm 200 - 250 - 300 mm
Length 50 - 5000 mm 50 - 5000 mm
Insulation Rockwool Rockwool
Thickness 25 mm 25 + 50 mm B-15 B-0
Density 31 - 35 kg/m³ 31 + 40 kg/m³
Weigth 9-8.7-8.5 kg/m² 11-10.7-10.5 kg/m²
Thermal isolation U=1.16 W/m² K U=0.42 W/m² K
* Other modules can be delivered (depending on quality) **Contact Norac for further information
54
WWW.NORAC.NO
0575
CEILINGS
TILES P-52
There are certain situations where only a
tile has the visual and functional qualities
required. C-class.
Steel structure
Air gap
300 mm
Donn profile
Insulated ceiling
Cabin / room area
B-0 / A-15 B-15 / A-30
P-53 plain tile. Non-combustible only
Description Tiles
Fire class (P-52 only) C-class Donn profile
55
WWW.NORAC.NO
0575
CEILINGS - DANACOUSTIC
TILES P-31
This type of ceiling is often used in public
areas. Norac delivered often the tiles integrated
with special beams, domes, etc.
Colour
Tiles are normally finished in white, but other
colour finishes can be supplied.
Installation
The tiles are held in place by rolled steel grid
sections providing a very rigid structure.
Description Tiles
Fire class C-class
Module width 300 x 300 / 600 x 300 /
600 x 600 mm
Insulation Rockwool
Thickness 25 mm
Density 31 - 35 kg/m³
Weigth 5.7 - 6.9 kg/m²
Material Aluminium
56
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
M1
Name Marine panel
System DMC M300 and DMC S300
37 12 Application Fire rated continous ceiling
Material 0.6 mm galvanized steel,
polyester painted
25,7
25
Length 75 – 6000 mm
Weigth Unperforated 6.6 kg/m2
175, 225 or 275 Perforated 6.1 kg/m2
(both including Rockwool)
M-2a
24 Name Edge trim
System DMC M300 and S300
Application Edge trim for longitudinally
cut in panels
Material 0.6 mm galvanized steel,
25,5
polyester painted
Length 2500 mm
Weigth 0.51 kg/m
25
M-3
Name Angle trim
System DMC M300 and S300
Application Edge trim for panels with
closed ends
40
P-90
Name Suspension angle w/lugs
System DMC M/M-T & RM/RM-T & S
Application Carrying ceiling panels along
the edge (longitudinally)
40
57
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
M-4
Name End edge trim
System DMC M300 and S300
Application Edge trim for closing open
27
M-7
Name U-profile w/lugs
36
System DMC M/M and RM/RM
Application Carrying ceiling panels
Material 1 mm galvanized steel,
polyester painted
19.9
Length 4500 mm
Weigth 0.55 kg/m
M6
Name Self-tapping panel screw
System
4,2
and u-profiles
Material Hardened steel, polyester
painted
16
Length 18 mm
Weigth 1.2 kg/m / 1000 pieces
P-3
Name Butterfly clip
System DMC panels and tiles
Application To clip onto u-profile
Material Galvanized steel
Length 150 mm
Weigth 0.035 kg/piece
15
58
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
P-3a
Name Hanging rod
System DMC panels and tiles
Application For suspension from deck
Material 4 mm diam. galvanized steel
Length 250, 500, 750, 1000, 1250,
1500, 2000 mm
Weigth 0.025, 0.050, 0.075, 0.100,
40
0.125, 0.150, 0.200 kg/piece
P-32
Name U-profile
System DMC DP and tiles
36 Application Carrying ceiling tiles
Material 1 mm galvanized steel,
polyester painter
Length 4500 mm
Weigth 0.55 kg/m
19.9
25.5
P-33
Name T-rail
35,5
System DMC tiles
Application Clip profile for tiles
Material 0.6 mm galvanized steel,
polyester painted
Length 5000 mm
Weigth 0.51 kg/m
25
59
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
P-36
18
Name T-rail (half)
System DMC tiles
Application Clip profile for files
Material 0.45 mm galvanized steel,
polyester painted
Length 3000 mm
21 0,3
P-34
Name Tail clip
System DMC tiles
Application Clip for connection between
P-32 and P-33
27
54
P-120
40
Name Hat profile
System DMC profile
Application Carrying P-121
Material 1.0 mm galvanized steel,
polyester painted
Length Custom-made
50
27
P-121
Name Hat profile
System DMC S-300
Application Carrying ceiling panels
25
25 40
60
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
P-122
Name Fish plate
System DMC S-300
Application Connection between
P-120 and P-121
80
Material 1.0 mm galvanized steel,
polyester painted
60
Length 80 x 60 x 1 mm
Weigth 0.037 kg/piece
P-51
36 Name U-profile w/lugs
System DMC RT-100
Application Carrying ceiling panels
Material 1.0 mm galvanized steel,
polyester painted
19,9
Length 5000 mm
Weigth 0.55 kg/m
P-10
Name Angle trim
System DMC tiles
Application Adjustment to wall
Material 0.45 mm galvanized steel,
35
polyester painted
Length 3000 mm
Weigth 0.22 kg/m
2.5
20
P-106
Name Joint profile
System DMC M-300
Application For butt-jointing panels
8
61
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
P-92
Name Butterfly clip with resilient
damper
System DMC panels and tiles
Application To clip onto u-profile
Material Galvanized steel / neoprene
Length 150 mm
Weigth 0.035 kg/piece
RM-1
Name RM
System RM
12 32,5 Application Fire rated continous ceiling
0.45 mm galvanized steel,
Material polyester painted
19,5
Length 75 - 6000 mm
20
P-55
Name RT
System RT
29.4 14.0 Application Fire rated continous ceiling
Material 0.45 mm galvanized steel,
polyester painted
15.0
15.0
Length 75 - 6000 mm
Weigth 80: 0.55 kg/m
80,130 or 180 130: 0.72 kg/m
180: 0.90 kg/m
P-31
Name Tile
System Tile
Application C-class ceiling
Material 0.7 mm polyester painted
aluminium
17
62
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
DP-1
Name DMC DP panel
DMC DP300
System Fire rated continous ceiling
Application 0.6 mm galvanized steel,
25 Material polyester painted
Length 75 - 6000 mm
175, 225 or 275
Weigth Unperforated 7.23 kg/m2
Perforated 6.73 kg/m2
(both including Rockwool)
P-52
Name DMC marine tiles
System DMC marine tiles
Application Fire rated tiles
23
63
WWW.NORAC.NO
0575
CEILINGS
COMPONENT LIST
P-3 / P-3A Butterfly clip with hanging rod
Tile
P-34 32 U-profile
P-33 T-rail
P-3a
P-3
M
fro ax 90
m 0m
wa m
ll 2
ma 3
x1
20
0m
m 1
64
WWW.NORAC.NO
0575
CEILINGS
LIGHT BOXES
Danacoustic ceilings are designed for
integration of light fixtures.
1400 390
30 mm Rockwool
Light fixture housing Conlit 150
(Glamox: with glass tissue
125
1247 272
M 300
M-7 P-3/P-3a
B
Fixture box
A A
B
300 430
145
Steel clip
70
70
Ø176
Downlight
Section C-C: Section D-D: (HØVIK: Casa marine H70B0)
C C
D
65
WWW.NORAC.NO
0575
CEILINGS
ACCESS HATCH
Danacoustic ceilings are designed for
integration of light fixtures.
1 600
B
L
LATCH 600
A A
L
PLAN B
REFLECTED CEILING PLAN
23,5
25 25
575
For B-15 rating:
SECTION A-A, INSULATED FOR B-0 RATING. An additional layer of insulation to be added.
M-7
600
66
WWW.NORAC.NO
0575
DOORS
CONTENTS
B-CLASS
MS 30dB / MC 41dB 68
67
WWW.NORAC.NO
0575
DOORS - B-RATED
MS / MC A
Integrated
drop-down treshold
(option)
Integrated
door close
(option)
A B
Description MS MC
Fire class C-class B-15 **
Surface doorleaf 0.6 mm steel sheets 200 - 250 - 300 mm
Frame (and top element) Painted, NCS & RAL colours 50 - 5000 mm
Top panel 41 dB
Thickness doorleaf 38 mm Rockwool
Weight (c.o. 750 mm) 57kgs 25 + 50 mm
Core material Rockwool 150 kg/m³ 31 + 40 kg/m³
Clear light opening Width: Standard up to 800 mm
Height: Standard up to 2000 mm
Element height Up to 3000 mm Up to 3000 mm Single door Kickout panel Ventilation louvre
Sound reduction Rw=30 dB Rw=41 dB
Standard specification Doorleaf PVC / PVC, hinges, frame, counterframe, overpanel, lockcase with
handle, escutcheon and stainless steel threshold.
68
WWW.NORAC.NO
0575
DOORS
MS / MC // TECHNICAL DETAILS
(UNDER REVISION) B
FRONT VIEW:
A A
20
VERTICAL SECTION:
HIDDEN DOORCLOSER
TOP ELEMENT
3
3
65
65
15
15
CLEAR OPENING
20
5
5
40
25
25
25
69
WWW.NORAC.NO
0575
GLAZED PARTITIONS
CONTENTS
(UNDER REVISION)
70
WWW.NORAC.NO
0575
FLOATING FLOORS
CONTENTS
(UNDER REVISION)
71
WWW.NORAC.NO
0575
FLOATING FLOORS
F300
Galvanized steel cassettes of 3 mm thickness.
72
WWW.NORAC.NO
0575
WET UNITS
CONTENTS
Prefabricated Wet Units 74
Typical Designs 75
Details 76
Installation 79
Standard Equiptment & Accessories 80
NOTE:
73
WWW.NORAC.NO
0575
WET UNITS
PREFABRICATED WET UNITS
With many years of experience and specialized
competence, Norac AS offer fully fitted wet
units. The Norac modular wet units are ideal
for marine accommodations, from cruise ships
to offshore installations.
ALUMINIUM CONSTRUCTION:
74
WWW.NORAC.NO
0575
WET UNITS
TYPICAL DESIGN
Type 1 (1120 x 1240 mm) A - module Type 2 (1420 x 1720 mm) B - module Type 3 (1720 x 2020 mm) C - module
Type 4 (1200 x 2000 mm) B - module Type 5 (1500 x 1600 mm) B - module Type 6 (1600 x 1085 mm) A - module
Type 7 (1650 x 1180 mm) B - module Type 8 (1660 x 1250 mm) B - module Type 9 (1925 x 1125 mm) B - module
Typical standard details Wet units can, upon request, be delivered in These units are for guidance only. We deliver
“knock down” execution. units according to customer specification and
Scupper Steel with grate of stainless steel
design.
Outlet greywater Plastic pipe (PEH-HT) 50 mm A = Toilet module
Fresh water Insulatet cu-pipe prisol 12 mm B = Shower module
pipe C = Bath module
Connection B.S.P. 1/2”
Electrical cable 3 x 1.5 mm²
Conduit pipe Flexible
Door hinges Stainless steel
75
WWW.NORAC.NO
0575
WET UNITS
DETAILS
75 50
Ceiling in wet units
25
25
20 mm insulation
Top frame
20 mm insulation glued on top panel
Top frame
Threshold cover
stainless steel
20 mm air gap
Silicon
Tiles Threshold cover
stainless steel
Bottom frame 200 mm
Silicon joint
Tiles
Silicon joint
Bottom frame 200 mm
20 mm insulation
glued on panel
20 mm insulation
glued on panel
20
20
Adjustable screw, M20 x 60 mm Steel deck Steel deck Adjustable screw, M20 x 60 mm
Door leaf
75
50
3 plastic nob
45 Inside wet unit 45 Wet unit 35 600 35
Clear opening wall panel
600 mm Right opened door - DIN R
As standard the external linings slide into the door frames. Norac wet units can be supplied with the cabin side having a finished surface as shown
above.
76
WWW.NORAC.NO
0575
WET UNITS
DETAILS
Norac wet units can be delivered with different
draining systems according to our customer’s Ceiling panel - finish inside wet units
specification.
Shower area
Screed
A / heating cables
Variable
50
SOLUTION FOR HEATING CABLE AND / OR STEP
/ wallpanel
Silicone
joint
Details of optional
heat-edge of floor
The floor pan is fully tested water tight, blasted and primed
before application of finish B
Variable
77
WWW.NORAC.NO
0575
WET UNITS
DETAILS
Standard Standard
Norac Responsibility: Yard Supply:
Electrical cable
Penetration frame
Ventilation duct
EL-junction box
(the connection can also
be done in the junctionbox Black water (toilet)
beside door)
Grey water
(shower and sink)
Grey water connection
50 mm
Interface responsibility
78
WWW.NORAC.NO
0575
WET UNITS
INSTALLATION
The standard units are delivered each with
four square tubes for easy lifting and locating
on board. A specially designed lifting frame is
used for hoisting by crane.
ADJUSTING HEIGHT OF
BATHROOM UNIT - OPTION
D
A
B C
A) Steel plate, 100 x 100 x 10 mm B) M20 x 50 mm adjusting bolt 5 off per unit
C) After adjusting of wet unit weld the bolt to the steel deck D) Tube 30 x 30 x 2 L = 300 for lifting (4 corners)
79
WWW.NORAC.NO
0575
WET UNITS
STANDARD EQUIPMENT / ACCESSORIES
Wash-basin, white china (500 x 355 / 600 x 450) Mixing tap Folding seat
80
WWW.NORAC.NO
0575
WET UNITS
STANDARD EQUIPMENT / ACCESSORIES
Light fitting, 1 x 18 W with razor socket 110 / 220 V IP44 Toilet cabinet Towel rail (all in length 30 - 45 - 60 cm)
81
WWW.NORAC.NO
0575
WET UNITS
STANDARD EQUIPMENT / ACCESSORIES
Toilet paper holder Spare paper holder Toilet brush and holder
82
WWW.NORAC.NO
0575
COLOUR AND SURFACES
COLOUR AND SURFACES
PVC coated steel or aluminium sheets
Decorative foil with strippable protective film.
The foil complies with international regulations
for spread of flame tests to class 1, and may
be used for all interiors on board. Available in
a great variety of colours.
Dobel 2000
PVC free sloution. Dobel 2000 consists of a
20 µm thick printed polyester foil laminated
into painted metallized steel. Allows multiple
colours/patterns.
83
WWW.NORAC.NO
0575
FIRE CLASSES & CERTIFICATES
FIRE CLASSES & CERTIFICATES
Fire Certificates/descriptions
All products contained in this catalogue
have been tested according to the latest
international regulations and test procedures,
and are approved by the worlds main
certification bodies. The energy generated from
the test fire in the heating chamber follows a
standardized temperature-time curve. B15 fire
class proves that the temperature at the cold
side does not exceed the standardised limits
for a period of 15 minutes. The procedure for
other fire classes follows the same procedure.
• B-class
Systems* are exposed to the fire for 30
minutes and must comply with stability and
integrity requirements within this time.
• A-class
Systems* are exposed to the fire for 60
minutes and must comply with stability and
integrity requirements within this time.
• H-class
Systems* are exposed to a hydro carbon fire
for 2 hours. The test procedure is similar to the
A-class test, but the rate of temperature rise is
far more rapid and to higher temperature level.
• MED (Europe)
• DNV
• Bureau Veritas
• US Coast Guard
• American Bureau of Shipping
• Transport Canada
• Russia Register of Shipping
84
WWW.NORAC.NO
0575
FIRE CLASSES & CERTIFICATES
MANAGEMENT SYSTEM CERTIFICATES
85
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
86
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
87
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
88
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
89
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
90
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
91
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
92
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
93
WWW.NORAC.NO
0575
REFERENCES
COMMERCIAL VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
94
WWW.NORAC.NO
0575
REFERENCES
CRUISE VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
95
WWW.NORAC.NO
0575
REFERENCES
CRUISE VESSELS
Shipyard / Customer Owner / Operator Vessel / Project Yard no. Year Walls Ceiling Wet units Doors Windows Various
96
WWW.NORAC.NO
0575
REFERENCES
OFFSHORE
Shipyard / Customer Owner / Operator Vessel / Project Year Walls Ceiling Wet units Doors Windows Various
97
WWW.NORAC.NO
0575
REFERENCES
OFFSHORE
Shipyard / Customer Owner / Operator Vessel / Project Year Walls Ceiling Wet units Doors Windows Various
98
WWW.NORAC.NO
0575
REFERENCES
OFFSHORE
Shipyard / Customer Owner / Operator Vessel / Project Year Walls Ceiling Wet units Doors Windows Various
99
WWW.NORAC.NO
0575
REFERENCES
OFFSHORE
Shipyard / Customer Owner / Operator Vessel / Project Year Walls Ceiling Wet units Doors Windows Various
100
WWW.NORAC.NO
0575
CONTACTS / ADDRESSES
EUROPE / ASIA
SALES@NORAC.NO - WWW.NORAC.NO
101
WWW.NORAC.NO
0575
AGENTS / DISTRIBUTORS
EUROPE
102
WWW.NORAC.NO
0575
AGENTS / DISTRIBUTORS
RUSSIA
BALTINOR LTD
Office 516-1,
Verbnaya st. 27-A,
Saint Petersburg, 197375
baltinor@baltinor.ru
natalia.gulnova@baltinor.ru
103
WWW.NORAC.NO
0575
AGENTS / DISTRIBUTORS
ASIA
104
WWW.NORAC.NO
0575
AGENTS / DISTRIBUTORS
AMERICA
1767 12th street #128 1680-D River Road Tel +49 40 320 856 13
Hood River 0r Manotick, Ontario K4M 1A3 Fax +49 40 320 856 11
Tel +1 503 789 7599 Tel: +1 613 692 1114
charlie@shipinteriorsystems.com Fax: +1 613 692 1342
scant@emarservice.com
105
WWW.NORAC.NO
0575