Professional Documents
Culture Documents
Mud Logging Unit Specification
Mud Logging Unit Specification
Ex-
Escape
window
A60
Sensor Fire-
warehou proof A0 Fire-
proof
CO2 Analyzer
Geochemical
Detector
Server Computer
Fluorescence
Detector
Real Time
P.K Detector Monitoring
Power Device
Safety indicator of instrument room: The insulation resistance between the phase wire
and earth lead of the instrument shall be equipped with more than 2 MΩ earthing device.
The analytical cycle of C1-C5 is 30s/90s with blowback (two cycles switching by one key)
The concentration rate of 100:1 (10%C1: 0.1%C2) can be identified obviously
Chromatographic emendation curve can be calibrated with two points.
Measurement range of C1~C5: 5 ppm-100%, Measurement range of Total Gas (TG):
10ppm -100
Display on large TFT LCD and operation with touch screen.
Stable, reliable and convenient for maintenance based on integrated components.
Intellectualized control, auto-firing, auto-zero point calibration and automatic trouble
shooting ability.
Various output interfaces such as serial port, parallel port, network, and recording
instruments.
Appearance of product Graph of peak value Geological guide The storing time of data can
be up to several months and the instrument can either run individually or be used on-line
with computer.
Specification
Measuring mode: Continuous
measuring
Measuring range: 0-100%
Sensitivity: 0.1%
Input voltage: 220V±10%
Output signal: 1-5V
Specification
H2 volume of generation: 0~400ml/min
Output pressure: 0.4MPa
Power ADC voltage: 220V, frequency: 50HZ±5HZ
Work environment temperature (5~40)0C
Characteristics
No-oil, light, low noise.
Unit will stop work automatically
when it is excessive hot.
When power cut suddenly, unit will
start automatically through
discharging pressure after power on
again.
Specification
Discharging volume: 0.07m3/min
Work pressure: 0.4, 0.8Mpa
Power voltage: 220V, frequency: 50HZ±5HZ
Gas storage volume: 0.016m3
Electromotor power: 500w