Moisture - Density Relationship - 000001
ASTM D698
Sample Information
Sample Number: 58286 Sampled By: Plasencia, Juan
Sample Date: 06/14/2019
Phase: Geotechnical Services
Location Details:
Location: Structural Fill Southwest of the intersection of Missouri Highway 150 and Botts
road, KCMO
Lab: 1700 East 123rd Street, Olathe, KS, 66061
Laboratory Data
Method: A (ASTM D698)
Preparation Method: Dry
Rammer Type: Mechanical Round
Specific Gravity: 2.70
Max. Dry Density (pcf): 98.2
Optimum Moisture (%): 22.4
Soil Classification: CH Fat Clay
Visual Description: fine grained, reddish brown