Professional Documents
Culture Documents
ANSYS Forte Best Practices
ANSYS Forte Best Practices
ANSYS Forte Best Practices
ANSYS, ANSYS Workbench, AUTODYN, CFX, FLUENT and any and all ANSYS, Inc. brand, product, service and feature
names, logos and slogans are registered trademarks or trademarks of ANSYS, Inc. or its subsidiaries located in the
United States or other countries. ICEM CFD is a trademark used by ANSYS, Inc. under license. CFX is a trademark
of Sony Corporation in Japan. All other brand, product, service and feature names or trademarks are the property
of their respective owners. FLEXlm and FLEXnet are trademarks of Flexera Software LLC.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFID-
ENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS. The software products
and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates under a software license agreement
that contains provisions concerning non-disclosure, copying, length and nature of use, compliance with exporting
laws, warranties, disclaimers, limitations of liability, and remedies, and other provisions. The software products
and documentation may be used, disclosed, transferred, or copied only in accordance with the terms and conditions
of that software license agreement.
ANSYS, Inc. and ANSYS Europe, Ltd. are UL registered ISO 9001: 2015 companies.
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the use,
duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS, Inc.
software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software
and third-party software. If you are unable to access the Legal Notice, contact ANSYS, Inc.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. iii
Best Practices
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
iv of ANSYS, Inc. and its subsidiaries and affiliates.
List of Figures
2.1. Sector mesh bowl profile and topology control points ............................................................................. 5
2.2. STL dialog when reading STL files into Forte .......................................................................................... 13
2.3. Green region is the valve, pink is the port. Note the donut surface around the intersection of the two ..... 14
2.4. Suggested refinements for typical engine cases ..................................................................................... 16
2.5. SAM control for resolving flow fields ...................................................................................................... 18
2.6. SAM control for resolving reactive regions ............................................................................................. 19
2.7. Turbulent flame-speed input parameters ............................................................................................... 22
2.8. Example of a Flame Library for a TRF gasoline ........................................................................................ 23
2.9. SAM settings for flame propagation ...................................................................................................... 24
2.10. Copy and Paste buttons located at the top of Editor panels .................................................................. 25
2.11. SAM settings for spray vaporization ..................................................................................................... 26
2.12. Valve stem split off from the valve face ................................................................................................ 27
2.13. Valve tilt angles ................................................................................................................................... 28
2.14. Indicating the marker point location for a region ................................................................................. 30
2.15. Turbulent Kinetics Interaction Model (TKI) panel .................................................................................. 31
2.16. Dynamic Adaptive Chemistry (DAC) panel ........................................................................................... 32
2.17. Sample geometry with gap demonstration .......................................................................................... 35
2.18. Gap too large ...................................................................................................................................... 35
2.19. Gap too small ..................................................................................................................................... 36
2.20. Acceptable gap ................................................................................................................................... 36
2.21. Mismatch in angular resolution causing self-intersections .................................................................... 37
2.22. BDC position translated to TDC ............................................................................................................ 38
2.23. Motion Type set as Sliding Interface ..................................................................................................... 39
2.24. Directions of normal vectors ............................................................................................................... 39
2.25. Geometry with enclosed piston ........................................................................................................... 40
2.26. Geometry with moveable piston ......................................................................................................... 40
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. v
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
vi of ANSYS, Inc. and its subsidiaries and affiliates.
List of Tables
2.1. Parameters providing secondary impacts on engine behavior ................................................................. 7
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. vii
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
viii of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 1: Forte Best Practices Introduction
ANSYS Forte best practices are presented in this book on these topics:
Further information about ANSYS Forte is available in the Forte Quick Start Guide, Forte User's Guide,
Forte Theory Manual, and Forte Tutorials. Documentation and tutorials are availalable from the ANSYS
Help site.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 1
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
2 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 2: Best Practices
This chapter presents the current best practice recommendations for ANSYS Forte, covering the following
topics:
2.1. Operating Environment
2.2. DI Diesel Engine Case (Typically, Sector Mesh)
2.3. Setting Up Automatic Mesh Generation Cases With Valve Motion
2.4. Setting Up Two-stroke Engine Cases
• For chemistry-intensive simulations with a large mechanism (>300 species), we recommend 8–16 CPUs per
job.
• Processor: 64-bit with recommended memory. Intel is recommended over AMD. The faster the processor,
the better.
• Parallel operation: Intel MPI is required; MPICH2 may be compatible but is untested and is not officially
supported.
Pay special attention to units. Be sure you enter units correctly as specified for the case, and do all
the conversions correctly or allow the Simulation Interface to convert values for you whenever possible.
These comments apply to using the Sector Mesh Generator , which opens into its own window
from the Geometry Editor panel.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 3
Best Practices
1. X is the radial direction from the center axis of the cylinder toward the cylinder wall (liner). A value of X=0
is at the cylinder center axis. At the cylinder wall, the value of X should be Bore/2.
2. Z is the vertical distance from the face of the piston lip in the direction of the cylinder head. The value of
Z=0 must be at the outer edge of the piston face (closest to the cylinder wall). Z coordinates into the piston
bowl will be negative.
3. The first point in the bowl profile should be the outer point on the piston face nearest to the cylinder wall
(Z=0, X= Bore/2 - crevice_width). If the X coordinate is smaller than Bore/2 - crevice_width, the mesh gener-
ator will automatically extend the profile to this point. The actual first point will be set to (Z=0, X= Bore/2
- crevice_width).
4. If you have no information about the crevice, start with the default crevice values (1 cm long, 0.1 cm wide).
Note that the “crevice width” cannot be set to 0, even if the Include crevice volume option is un-
checked. Similarly, the radial cell count corresponding to the crevice width cannot be 0. In other
words, even if you do not want to include the crevice block, the topological block above the crevice
must always be retained.
If you do not want to mesh the crevice volume, the Include crevice volume option should be un-
checked, and the Axial cell count corresponding to the crevice volume should be set to 0.
Only include points that describe the profile from the piston face outer edge to the tip of the bowl at
the center axis. Do not include points on the cylinder head.
The Sector Mesh Generator will assume a flat cylinder head. If this is not desired, you must generate
the mesh using ICEM CFD or K3PREP, or consider using a 360° mesh instead of a sector mesh. Forte
also is able to model sector engine geometry using Automatic Mesh Generation, which can also handle
sector geometry with a non-flat cylinder head.
Determining Mesh Control Points and Size Parameters is an iterative trial-and-error process. The Mesh
Control Point “fractions” are fractional distances along the entire length of the bowl profile. So if you
think about stretching out the profile into a straight line and scaling it to a distance of 1.0, the control-
point location parameters are the distance where each control point lies along this line, starting from
the outer edge (Z=0, X=Bore/2-crevice_width). Make your best guesses, since it is easy and quick to iterate
once you create an initial mesh. For example, for Topology #1, you might have 0.25,0.3,0.4, 0.7, for your
starting locations for Control Points 1,2,3,4, respectively.
Cell counts are estimated based on trying to make the side size of any cell somewhere between 1 and
2 mm, where ~1.3 would be better for production runs, but ~2 might be better for initial setup verific-
ation (that is, the coarser mesh will run faster).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
4 of ANSYS, Inc. and its subsidiaries and affiliates.
DI Diesel Engine Case (Typically, Sector Mesh)
Figure 2.1: Sector mesh bowl profile and topology control points
1. Intake port/inlet composition for engine cases with valves and ports.
2. Exhaust port initial composition for engines cases with valves and ports.
3. In-cylinder initial composition at IVC for engine cases that are in-cylinder only.
The Composition Calculator can be accessed from the Utility menu or the Composition Calculator
button on the toolbar. Please refer to the Forte User's Guide, for further details of how to use the
Composition Calculator utility.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 5
Best Practices
The molecular weight of NO (30 g/mole) is about the same as air or vitiated air (~29 g/mole). For this
reason, adding 25 ppm (0.000025 mole fraction) of NO is approximately equivalent to adding 0.000025
mass fraction. For a more exact calculation, you would need to convert the mass fractions of the initial
composition to mole fractions, add the ppm NOx, re-normalize, then convert back to mass fractions.
If the per-stroke fuel data [mg/stroke] is given for one cylinder, then the Forte input is:
If the per-stroke fuel data [mg/stroke] is for the whole engine, that is, for a multi-cylinder engine, then
the input to Forte is:
1. Use the given initial Pand T and run the case to ~2 CA before start of injection.
2. Compare the predicted pressure profile up to this point with the measured values. If the pressure is too
low or too high just before start of injection (SOI), adjust the IVC pressure value. However, this adjustment
should be no more than ~3 PSI, which is less than ~0.2 bar.
3. Since the measured temperature is derived from the pressure and it is important to keep the total mass in
the system consistent with measured values, also scale up the IVC temperature according to the adjustment
made to pressure. In other words, if you change the initial pressure from 1.0 bar to 1.1 bar, also increase
the initial temperature by a factor of 1.1 (that is, if it was 400 K, it should now be 440 K).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
6 of ANSYS, Inc. and its subsidiaries and affiliates.
DI Diesel Engine Case (Typically, Sector Mesh)
The best way to judge the injection timing is to compare the heat-release rate between prediction and
experiment. Both are usually derived from the pressure trace, but this comparison shows more clearly
the ignition timing than the pressure trace itself. The initial ignition behavior will be strongly dependent
on the injection timing. The following adjustments may be acceptable:
1. If your heat-release peak is shifted by a couple of crank angle degrees relative to experiment, then you can
shift the SOI of injection accordingly. This assumes that the width of the HRR curve is about the same as
the data.
2. If the predicted HRR curve shows a higher peak and skinnier profile than the data, you might need to adjust
the duration of injection. (Or, conversely, a low peak with an overly fat HRR may need a shorter duration.)
3. If there are multiple injection events, then this problem becomes more complicated. You may be able to
see the HRR signature from the different injections, depending on how much heat is released as a result,
but it may be hard to justify independently moving one peak relative to another or changing fuel splits.
One would expect that the timing delay between actuator and fuel injection would not be different for
different injection events, so the safest bet would usually be to shift all events together.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 7
Best Practices
The HRR profile can be calculated directly from the pressure vs. CA data in Excel, using the following
formulation:
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
8 of ANSYS, Inc. and its subsidiaries and affiliates.
DI Diesel Engine Case (Typically, Sector Mesh)
Here Q is the heat-release, and is the heat-release rate, which is usually desired in J/degree units.
CA is the crank-angle, gamma is the specific heat ratio of the gas, which we take to be 1.35, V is the in-
cylinder volume, and p is pressure. Note that Forte uses this same formula in the calculation of the HRR
in the thermo.csv file.
If the volume of the chamber is not available, it can be calculated from the crank angle and engine
parameters. First calculate the position of the piston, which will require the connecting-rod length (L)
and the crank radius (R). Then, use that along with the engine Bore and the clearance volume to calculate
the total volume in the cylinder at each crank angle. The calculations are as follows:
5. Be careful with unit conversions! …It’s a good idea to compare the calculated volume profile with
that calculated by Forte to make sure no mistakes have been made in steps 1 & 2.
Note: You can create a dummy thermo.csv in a folder that resides as a parallel-level directory to
your run directory and put the CA vs. AHRR data into that file for direct comparisons during run-time
using the Monitor plotting. For example, create a directory called xData_Run1 and place it in the
same parent directory of the Run001 directory, then copy any thermo.csv file into the xData_Run1
folder; edit it and replace the CA, P and AHRR columns with the experimental data (with the units ex-
pected in thermo.csv), but zero out all other columns. Now your plot will show your run-time com-
parison in the Monitor window.
1. CA_ATDC (degrees)
2. P_Case1 (bar)
3. Volume (cm3)
4. HRR_Case1 (J/degree)
With the columns of data set up in this way, save the sheet as a comma-separated-values text file (.csv)
using Excel’s “save as … other format” option.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 9
Best Practices
From the ANSYS Forte Visualizer, you can now import the data, using the File > Import menu command.
Allow the software to read the labels from the csv file. It should parse the unit strings in parentheses
and then will know the units context, such that conversions can be made using the Units Preferences
options.
For a “good engine” we’d expect the combustion to be taking place primarily in the bowl and that the
droplets are getting consumed before they hit the wall. If spray seems to be impinging on the wall
(undesirable) this could point to issues with the spray model, such as the discharge coefficient being
too high, for example. If spray droplets are migrating out of the bowl and persisting into the expansion
stroke, then the vaporization or fuel model may not be the best for this case. While it is possible these
types of phenomena are real, it is good to first check whether inputs are reasonable and that the results
are not sensitive to some estimated parameter.
Another good check is to confirm that the total mass of fuel injected, as reported at the end of the
Forte log file, matches the value input in the spray injection data. This should be the total fuel injected
for all nozzles (that is, not just the one nozzle represented in the sector), since that is what is measured
and Forte takes care of the periodicity internally.
2. Thermal Efficiency
3. Emissions indices for NOx, CO, UHC (unburned hydrocarbons), and soot, in the units of g/kg-fuel. These
values are at the end of simulation, usually exhaust-valve opening, so they are engine-out conditions,
not exhaust-system-out.
In addition, species emissions in the units of PPM can be determined from the molefraction.csv file
found in the working directory of each parameter-study run. To get EVO emissions numbers, scroll down
to the EVO crank angle (last row) and then go to the column for the molecule of interest. Note that the
fraction of NOx is the sum of the fractions of NO + NO2. PPM is 106 times mole fraction.
Note that, for an in-cylinder-only simulation, the IMEP and ISFC are calculated based on integrating the
P-V curve for the compression and expansion strokes (i.e., -180 CA ATDC to 180 CA ATDC, where 0 CA
ATDC is the firing TDC), which is different from what is measured. Typically, an in-cylinder-only simulation
starts from IVC and ends at EVO. The P-V curve between IVC and EVO is integrated directly. The integ-
rations for “-180 CA ATDC to IVC” and “EVO to 180 CA ATDC” are approximated. For example, the work
for “EVO to 180 CA ATDC” is approximated as 0.5*(PIVC+PEVO)*(VEVO-VBDC), in which PIVC and PEVO are
the pressures at IVC and EVO, respectively; VEVO and VBDC are the volumes at EVO and BDC, respectively.
Also, measurements are usually based on brake power, rather than indicated power. So we expect these
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
10 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
to be approximate rather than an exact match, relative to the data; however, we do expect the predicted
results to follow the correct trends.
* Total_fuel_injected [kg/cylinder/cycle]
* (RPM/Revolution_per_cycle) * 60 [cycle/h]
General notes on the use of ANSYS Forte and configuring it for your use:
• The geometry units must be cm. If the surface mesh does not use cm units, please choose the correct unit
in the Import dialog and Forte will automatically scale the geometry to use cm units. If you forget to specify
the correct unit, simply select all the surfaces in the Geometry tree, right click, select Transform and specify
the correct scaling factor for the X, Y, and Z direction.
• Units are completely configurable in Forte, both in the Setup and the Visualizer. Units can be modified inline
in the input panels, or by going to Edit > Preferences > Units Preferences. You can chose from CGS, SI,
British, or create your own Custom unit preferences.
• Have the surface mesh file written from the CAD program so that the surfaces are different parts inside the
surface mesh file, or so each unique boundary is a separate surface mesh file. This saves time since you will
not need to split the geometry.
• The geometry should be watertight in Forte. If the surface mesh is not watertight, Forte will identify the region
where the issue occurs in red.
• The valves should be closed with a very small gap, but not coincident.
• Specify approximately 10 GB of memory for Forte Simulate (if generating preview meshes) and for the
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 11
Best Practices
Whenever possible, STL files should be a last choice as a source of surface mesh data. STL files lack
surface topology information. As different programs may infer different topologies from the same source
file, there is no way to reliably confirm or test whether an STL is, for example, watertight.
Currently, the best alternatives to STL files supported by ANSYS Forte are Fluent mesh format and CGNS
format. Both of these formats encode topological information about the surface.
A recommended procedure for generating a surface mesh for importing to Forte is:
1. Create a “Mesh” object in ANSYS Workbench and import your geometry, then launch the mesher.
a. Defaults:
b. Sizing:
Transition = Slow
c. Defeaturing:
3. Generate just the surface mesh by right-clicking the Mesh object > Preview > Surface mesh.
5. In ANSYS Forte, import the surface mesh using the From Fluent mesh import option; select meters as the
units.
6. When the import gets to the “Checking surface” phase, cancel it with the red X. (Otherwise the surface
checker will report problems because the normals are reversed; see the next step.)
7. Reverse the normals for the imported surface—everything should go from dull to shiny.
8. Run the surface checker manually (from the Geometry toolbar). It should now pass.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
12 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
• If you end up with some small pieces, try to collect those and merge them into the bigger pieces, using the
Merge utility.
• If you need to split surfaces further, consider using the cut-plane option or adjusting the feature angle that
was used for the Split utility.
Ultimately, you want to end up with the following surfaces that are separated and free of holes:
1. Individual valves
4. Cylinder head
5. Cylinder liner
7. Inlet boundary
8. Outlet boundary
It is easiest if the separate boundaries, such as ports, valves, etc., are written as separate parts in the
surface mesh file or as separate surface mesh files all together. You can select multiple surface mesh
files to read into ANSYS Forte. (The surface mesh must be watertight.) Once again, the geometry should
be in units of cm in Forte. If the geometry is not in cm, specify the unit used for the geometry and Forte
will convert the geometry to cm units upon reading it into the user interface.
Figure 2.2: STL dialog when reading STL files into Forte
The valve stems should be cut and flush at the location where they meet the port (at the end of the
valve stem/port connection).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 13
Best Practices
Figure 2.3: Green region is the valve, pink is the port. Note the donut surface around the
intersection of the two
Note
If the crevice volume is included in the geometry, this volume should be resolved sufficiently
using surface refinement such that there is at least one layer of cells between the two walls
of the crevice gap. However, resolving the crevice gap using tiny cells will increase the cell
count of the mesh and potentially affect solution speed. Therefore, it is desirable to not include
the crevice region in the geometry unless it is absolutely necessary.
2.3.1.3. Normals
In the surface mesh geometry, the normals all need to be consistent. The normals should all point to
the solid region, so for the valves, the normal should point to the center of the valve.
If the normals for some triangles are not consistent, the geometry is not considered to be watertight
and these triangles will be highlighted with a red outline.
• To separate these inverted triangles, go to the Workflow tree and select the surface that contains the inverted
triangles. Split Mesh and select the Feature Angle option. On the Feature Angle dialog, specify a Feature
Angle of 175 as shown in the figure below.
• This will split off all inverted triangles, and you can then use the Reverse Normal tool to correct the
normal.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
14 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
• Note that the geometry will not be watertight at this point since the triangles are not considered to share
vertices. To fix this, the final step is to use the Join Meshes (not to be confused with the Mesh Merge) tool
to join all the surfaces back together. At this point, the red outline of the offending triangles should disappear.
Note
Select a point that will be inside the cylinder at all times during the cycle. Usually this means just
below the head, at the cylinder axis, above the highest point of the piston bowl at TDC. Be sure the
material point is not placed in-line with any of the valves.
A Small Feature Deactivation Factor can be used to remove very tiny features from consideration during
the computation. This factor is applied globally to the geometry. The value ranges from 0 to 1, where
a higher value will filter out more small features. The default is 0.25 and it is suggested that this option
be left at the default value.
A recommended global mesh size is 2 mm. But for large-bore diesel engines, it may be acceptable
to use 3 mm for the flow portion of the cycle, while for a smaller-bore gasoline engine 1.5 mm may be
more appropriate. You can then use region-based refinement to set a smaller mesh size (for example,
1/2) in-cylinder during spray/combustion.
Mesh refinements are used to resolve both surfaces and regions within the computational geometry.
Note that refinements should be added to sufficiently resolve all crevices in the geometry, that is, small
physical gaps in the geometry, otherwise robustness may be affected. In all cases, refinements are added
in 1/2!, which would be 1/2, 1/4, 1/8, and 1/16.
Each of the mesh-size controls can be specified as static (Always active) or dynamic (active only During
specified time or crank-angle intervals). For example, refinement in the squish region near a moving
piston boundary may only be necessary when the piston is near top-dead-center (TDC) position. For
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 15
Best Practices
simulation of a full cycle, this may mean setting two controls for the two intervals (for example, 350 to
370 CA, 710 to 730 CA) during the cycle of a 4-stroke engine while the squish region is most active.
ANSYS Forte has several refinement types that are useful for resolving the geometry. They fall in two
main categories: (1) surface refinement, and (2) volume refinement. Volume refinement is further divided
into two categories: (2a) fixed volume refinement, and (2b) Solution Adaptive Meshing (SAM). Surface
refinement should be used in every case. SAM with limited fixed volume refinements is recommended
for volumes.
1. Surface Refinements:
Applied to surfaces to refine the shape. Certain areas of a surface, such as complex geometries, open
boundaries, and valves, require additional attention to accurately resolve the geometry and moving
surfaces.
Figure 2.4: Suggested refinements for typical engine cases (p. 16) shows the suggested refinements
to be used for most engine cases. Details of each refinement are given.
• all_walls: Surface refinement applied to all wall boundaries as a base setting. Typically, ½ refine-
ment is used (Active = Always).
• open_boundaries: Surface refinement applied to the inlets and outlets of the domain. Typically,
½ refinement is used and the number of layers to extend is specified as 2 (Active = Always).
• squish_ftdc and squish_ltdc : Surface refinement applied to the head, piston, and liner surfaces
for the TDC events. Typically, ¼ refinement must be added such that the TDC clearance height is
resolved (Active = During).
• valves: Surface refinement applied to the intake and exhaust valves. Typically, ¼ refinement is
required on the valve. The valve may be split into two parts, stem and face, to save a mesh count
with deeper refinement applied only to the face near the seating area. If more refinement is desired
near the valve seating area, ¼ refinement can be applied to the head or port regions.
• crevice: If a crevice volume is included between the piston edge and the liner wall, this area
should be resolved sufficiently using surface refinements such that there are 2 cells across the
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
16 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
crevice gap. Typically, 1/8 refinement is needed with multiple layers to fill the crevice gap. To reduce
the mesh count, the piston or liner surface can be split to apply deeper refinement only to surfaces
that form the crevice (Active = Always). (See Modeling the Crevice (p. 20)).
• spark_plug: Point refinement applied to the spark plug. Typically, 1/8 refinement is used to suffi-
ciently resolve the geometry and the spark gap, but this will depend on the spark plug geometry.
The point refinement radius is typically specified such that 6 to 10 layers will resolve the region
around the spark plug and the resulting flame front. The refinement should result in about 3 cells
across the spark gap (Active = Always).
• Injector and glow plug: Surface refinement applied to the injector tip. Typically, ¼ refinement
is used to sufficiently resolve the geometry and the number of layers to extend refinement is
typically 2 (Active = Always).
• Feature refinement: This type of refinement can be specified on single or multiple surfaces. A
feature angle is specified to identify features on surfaces (smaller angle = greater feature refine-
ment). The user also specifies a radius that is applied to each identified location. This option is
useful when refining oddly shaped geometry.
2. Volume Refinements:
SAM should be used to resolve the flow field and reactive zone. Recommended options are using
velocity gradients and temperature gradients with statistical sigma threshold of 0.5, and ¼ refinement.
Velocity control should be active always and be applied to the entire domain (Figure 2.5: SAM control
for resolving flow fields (p. 18)). Temperature control can be limited to the cylinder region and be
activated prior to TDC for the combustion duration, as shown in Figure 2.6: SAM control for resolving
reactive regions (p. 19).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 17
Best Practices
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
18 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
Additional SAM controls should be used for accurately capturing the flame front and spray vaporiz-
ation. These are described in Models (p. 21). Additional SAM controls on species such as CO or soot
precursors (like acetylene and pyrene) may be used to better resolve emissions but they are not
necessary.
Fixed volume refinement should be used to provide some level of initial refinement in the regions
involving combustion and spray. Following these fixed refinement recommendations should provide
a good base mesh and help to achieve high fidelity results when used together with SAM.
• Secondary Region:
Under the Geometry node, secondary regions can be defined by selecting geometry to encapsulate
a region. Under the Mesh Controls, the secondary regions can be used to refine an entire region
(in other words, the chamber). Typically, this is a secondary volume encapsulating the in-cylinder
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 19
Best Practices
volume that can be created by selecting the surface that includes liner, piston, and head. The re-
finement level for the in-cylinder region should be set to ½ or ¼ to achieve a cell size no larger
than 1 mm and set to Always Active.
• Line Refinement:
The end points of a line and a radius are specified to define a cylinder where all locations inside
the cylinder are refined to the specified refinement level. Line refinement of ½ to ¼ should be
used to resolve near-nozzle regions during spray duration. Point refinement may be used instead
of line refinement depending on the geometry.
2. Split the piston so the side of the piston becomes a separate surface
3. Apply 1/8 or 1/16 refinement to the crevice bottom surface and the piston-side surface. The crevice thickness
will determine the refinement level to be used, but 1/8 or 1/16 is typically used to resolve the thickness.
4. If possible, modify the geometry such that the crevice thickness can be greater while capturing the same
volume, to avoid many highly refined cells.
To avoid display artifacts in post-processing, we recommend that a line refinement be applied along
the sector axis. The following are recommended settings for this line refinement:
• End Points: This line refinement should cover the full length of the axis when the piston is at the BDC position.
The end points can be set to (X=0, Y=0, Z1) and (X=0, Y=0, Z2), in which Z1 is the Z-coordinate of the top
end of the axis on the cylinder head, and Z2 equals the Z-coordinate of the piston center at the TDC position
minus engine stroke (assuming the piston moves towards the negative Z direction from TDC to BDC).
• Radius of Application: The radius should be larger than half of the global mesh size. Recommended practice
is to set the radius equal to the global mesh size.
• Size as Fraction of Global Size: The cell size of this refinement should be equal or smaller than the cell
sizes from other refinements. The goal is to maintain uniform cell size within the range of this line refinement.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
20 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
Note
Best practices for multi-cylinder simulations are described by the tutorial in the Forte Tutorials:
Multi-Cylinder Four-Stroke Engine Simulation.
2.3.3. Models
2.3.3.1. Turbulence Model
In modeling turbulent flows in internal combustion engines, the Reynolds-Averaged-Navier-Stokes
(RANS) approach is most efficient. It simulates the ensemble average of turbulent flow and transport
processes. The default option, RNG k-ε model, is recommended for most of the engine flow and com-
bustion problems. In general, there is no need to adjust the default model parameters.
The Large-eddy simulation (LES) approach is intended to simulate individual flow realizations rather
than the ensemble average. It is useful when simulating cycle-to-cycle variations of flows and combustion
outcomes in engines. The LES Smagorinsky model with its default model parameters is recommended,
due to its numerical stability in cases where complex engine geometry is considered. When the LES
approach is used, we suggest turning on the option of using central difference for momentum convection,
due to its better resolution in solving the large-scale momentum transport.
In general, LES requires finer mesh resolution than RANS to better resolve the turbulent transport pro-
cesses.
Typical values for the parameters that control flame speeds are shown in Figure 5 (p. 22).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 21
Best Practices
The turbulent flame speed is a function of the laminar flame speed. The Table Library model contains
Chemkin-based laminar flame speeds and computes flame speeds for the multi-component fuel on the
fly. It captures the influence of fuel composition, pressure, temperature, AFR, and EGR on the laminar
flame speed. A Flame Library should be created that includes fuel components when premixed or direct-
injection fuel surrogate are used in the chemistry. An example flame library for a TRF gasoline are shown
in Figure 2.8: Example of a Flame Library for a TRF gasoline (p. 23).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
22 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
The Turbulent Flame-Speed Ratio (b1) and the Stretch Factor Coefficient are the two inputs that may
require adjustment to match the pressure curve. See the tooltips and the Forte User's Guide for more
details on these inputs. Since the model formulation for the stretch factor is very sensitive to its input
parameters, including laminar flame speed, laminar flame thickness, and turbulence parameters, the
stretch factor may show strong fluctuation under strong turbulence and low laminar flame speed con-
ditions. Thus, it is recommended to keep the default setting of 0 for the stretch factor coefficient, and
adjust only b1. In the turbulent flame-speed correlation used by Forte, b1 is closed using experimental
data and thus can be adjusted for model calibration. A larger b1 will result in higher turbulent flame
speeds and faster flame propagation, and it has an impact throughout the flame propagation process.
If unable to match the pressure curve during flame propagation by adjusting b1, the Flame Development
Coefficient (FDC), which is another parameter available on the Spark Ignition Editor panel, can be adjusted
to improve flame propagation prediction. A larger FDC can result in faster growth of the flame from
ignition kernel flame stage to fully-developed turbulent flame, which in turn leads to faster burn rate.
FDC typically has larger impact on the early stage of flame propagation than the later stage. For the
other settings, default values are appropriate for most cases.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 23
Best Practices
In the G-equation model, the non-reacting scalar G is defined at each mesh vertex for the purpose of
marking the mean flame front location. The G value at a vertex is tracked as the signed normal distance
from the vertex to the nearest flame front surface. G < 0 in the unburned zone, G > 0 in the burned
zone, and the G=0 iso-surface marks the flame front location. Since Forte uses the CGS unit system, the
default unit for G is cm, although G is handled as a dimensionless quantity in the code and it involves
no unit conversion. In the example shown in Figure 2.9: SAM settings for flame propagation (p. 24), the
range of [−0.5, 0.25] means that the SAM refinement is applied within a band surrounding the flame
front. The bandwidths on the unburned side and burned side are 0.5 cm and 0.25 cm, respectively.
In addition, it may be productive to use additional SAM controls with gradients of either/both temper-
ature and of CO. Using temperature/CO control can be helpful for high compression conditions where
there could be a possibility of autoignition or reactivity ahead of the flame front. We suggest statistical
bounds with a Sigma Threshold of 0.5 to 0.75 for temperature. Using a smaller sigma value results in
more refinement. This refinement should be activated at or slightly prior to spark timing.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
24 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
gasoline sprays using Rosin-Rammler or Log-Normal droplet size distribution, explicitly specifying the
discharge coefficient should provide better representation of the injector exit. The discharge coefficient
for multi-bore high pressure injectors can be as low as 0.5, which is lower than that for most diesel in-
jectors.
For diesel fuel, specifying Uniform Size for the droplet size distribution is suggested. For gasoline sprays,
Rosin-Rammler distribution is more commonly used than log normal distribution. The Initial Sauter
Mean Diameter should be specified. For most gasoline cases, this is typically between 10–30 micron.
The actual droplet distribution is subject to an upper limit, which is the (nozzle diameter * Cd0.5).
For solid cone breakup, time constants for the KH model (primary breakup) can be adjusted within the
range suggested in the tool tip. The check box to Impose SMR Conservation in KH breakup should
be left unchecked for most conditions. However, it can be turned on for certain conditions such as low-
load low-temperature combustion diesel engines, for improving the pressure curve and emissions pre-
dictions.
The RT model for secondary breakup is important for most conditions. The RT distance constant can
be adjusted to improve the prediction of both spray penetration and combustion. A lower value of the
RT distance constant, such as 0.2, will activate the secondary breakup model closer to the nozzle. This
may be important for gasoline atomizers where spray breakup occurs very close to nozzle. For most
diesel engines, the RT distance constant typically varies within 40% of the suggested default value of
1.9. Refer to Table 1 (p. 7) for the typical qualitative impact on engine behavior.
When creating nozzles, first create one nozzle and specify all its settings, and then Copy it and Paste
repeatedly to create the remaining nozzles, modifying the copied settings as needed. This saves time
and only one parameter needs to be adjusted to change the orientation. The Copy and Paste buttons
are located at the top of appropriate Editor panels.
Figure 2.10: Copy and Paste buttons located at the top of Editor panels
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 25
Best Practices
1. The 2-step soot model: The Soot model in Forte where only acetylene (C2H2) is the precursor to soot
formation. Several values are available for adjusting the soot formation and oxidation. This option should
be selected if acetylene is the only precursor for soot. Note that the gas-phase chemistry mechanism must
contain soot as a species when this soot model option is used.
2. Pseudo-gas soot model: The pseudo-gas soot model was developed by ANSYS and is included with the
gas-phase chemistry set. A gasoline and diesel surrogate and mechanism are provided with the Forte in-
stallation. If you are using the pseudo–gas-phase soot model, the Soot Model option in Forte should not
be selected since all soot-related chemistry is included in the gas-phase chemistry file.
3. Method of Moments: The most detailed option for modelling soot is particle tracking. ANSYS Forte will
predict the average particle size and number density for every cell in the computation. To use this option,
choose the Method of Moments. There are two mechanisms for particle tracking included with Forte, one
for gasoline and one for diesel fuel. The Method of Moments option requires specifying the soot surface
chemistry mechanism.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
26 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
2.3.4.2. Valves
In this section, the setup of the intake valve is described. The same setup and procedure would be used
for the exhaust valves. We suggest that you set up one valve, then Copy and Paste it to create the
other valves.
In this setup, the valve stem has been split off from the valve face, as shown in the figure below. This
has been done to improve the speed in the calculation where Forte determines if the valve is open or
closed, that is, the specified gap between the valve and valve seat has been obtained. Splitting off the
valve face from the stem is not required, but it may improve simulation time since the refinement for
the valve opening gap is only applied to the valve face and not the entire valve.
Figure 2.12: Valve stem split off from the valve face
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 27
Best Practices
• Intake Valve Angle(θ) = 180 + valve_angle, for example, if the valves are canted 13 degrees, then the resulting
angle would be 193 degrees.
• Exhaust Valve Angle(θ) = 180−valve_angle, for example, if the valves are canted 12.6 degrees, then the res-
ulting angle would be 167.4 degrees.
• Sliding Interface: Used in ported engine cases where the piston covers/uncovers port openings to the cyl-
inder
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
28 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
For the Valve movement sub-type, the user needs to specify the valve seat and the surface it contacts.
The valve seat is the stationary portion that may be a part of the head or intake/exhaust port surface
and the surface it contacts is the valve itself.
In this case, some portions of the intake port (similarly for the exhaust port) have been split off and
labeled as the “seat”. This splitting is not a requirement, but has been done in this case to help with
the calculation speed of the valve opening/closing events (see Notes in the Valves section above). The
splitting is accomplished with a cut plane in the Geometry tree.
Select both the “seat” portion and the “valve” from the list by holding down the Ctrl key and clicking
with the left mouse to multi-select.
Now that the Valve movement subtype surfaces have been selected, you need to specify the Valve
Motion Activation Threshold, that is, the minimum gap before the valve is considered open or closed.
It is suggested to start with a 0.5 mm gap in the first simulation, and then you can use a smaller gap
if you are not satisfied with the results. The other required input is the Approximate Cells in the Gap
at Minimum Lift and this should be 2. Note that Forte automatically refines the valve gap such that
the specified number of cell layers can fit in the gap, so no special refinements are required for resolving
the gap.
To add a new Initial Condition, right-click Initial Conditions and select Add > Secondary Region. You
will need to add a total of two secondary regions, one for the intake, and one for the exhaust. The default
initialization will be applied to the cylinder, which is the region not marked by either the intake or the
exhaust secondary regions.
In the Secondary Regions, a location needs to be specified to mark the different regions. This is like a
Material Point for each unique region, so in this case there would be a marker point for the intake and
exhaust regions. The location of these marker points does not need to be exact, but they must be com-
pletely inside the port (region). The figure below shows where to input the location information for the
marker points in the initial condition panel of a secondary region.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 29
Best Practices
If you are running a sector mesh, or a combustion/expansion stroke only and the valves are not included,
you will only have one initialization (the default) and the initialization order for that region would equal
1.
• ANSYS Forte uses an adaptive time stepping approach where the user specifies a maximum time-step size.
The maximum time-step size in Forte can be a constant value or a profile, that is, a function of time or crank
angle. The following are suggestions for maximum time-step size:
– Sector Mesh Cases: 8E-06s during compression, 5E-06s during injection, combustion and expansion (Note,
it may be possible to increase the time-step size back to 8E-06s late in the expansion stroke)
– Automatic Mesh Generation Case: Prior to injection or combustion, a maximum time-step size of 1E-05s
can be used, during injection and combustion a maximum of time-step of 5E-06s should be used.
• Chemistry
• There are several options for reducing the simulation time for chemistry or modulating chemical heat release
rate by considering turbulent mixing effects. Below are suggestions for these options:
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
30 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
– Turbulent Kinetics Interaction (TKI): Sub-cell scale turbulence chemistry interaction can be accounted for
with the TKI model. This mixing time-scale model considers that the combustion chemistry should be
partly controlled by the breakup of turbulent eddies due to the imperfect mixing of fuel and oxidizer in
an actual engine process. The TKI model is recommended for use with high-load cases only; for low-load
cases the impact of the TKI model is expected to be much less. Also, the TKI model is recommended only
for cases with in-cylinder fuel injection, for which the TKI model would consider the effects of imperfect
mixing of fuel and oxidizer.
A value of 1.5 is recommended for the mixing time coefficient setting under the TKI model. While
a larger value of this input increases the turbulent mixing effect on reaction rates, a very high value
would also suppress chemistry for post-injection expansion stroke conditions.
– Dynamic Adaptive Chemistry (DAC): This option performs a mechanism reduction on the fly during the
simulation. It should only be considered when there are 500+ species in the reaction mechanism. For the
initial species, all fuel species, important radicals (such as OH, HO2), NO, NO2, and soot precursor species
(C2H2, soot). In the example below, the fuel n-heptane (nc7h16), and the soot precursors acetylene (c2h2)
and benzene (c6h6) are included.
For the search tolerance, the default value of 0.0001 is recommended. The Size threshold for ac-
tivating DAC acts as a trigger for activating DAC. This value represents the ratio of species in the
reduced mechanism to the number of species in the full mechanism. DAC will be enabled when
this ratio is smaller than the threshold set here. A value of 1.0 will result in DAC being always en-
abled. Depending on the size of the full mechanism, this value can be set between 0 and 1.
– Dynamic Cell Clustering (DCC): This option lumps together kinetically similar cells, thus reducing the size
of the chemistry problem to solve. This option should always be activated and the settings kept at the
default.
– Activating Chemistry: By default, chemistry is always solved, but this is not necessarily needed prior to
injection or spark timing. Use the Conditional option and activate the chemistry at the combustion event,
that is, injection or spark, and use the Threshold Temperature option.
Note
The chemistry activation controls using spark timing or injection timing will be ignored
after the first engine cycle. Because of this, we recommend using controls based on
crank-angle intervals for multicycle simulations. In a crank-angle-interval–based control,
both the user-specified starting and ending crank angles will be converted to fit in the
range of [0, 720) or [0, 360) CA degrees for four-stroke or two-stroke engines, respectively.
The chemistry activation/deactivation events will consequently be examined in those
engine cycle ranges.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 31
Best Practices
• Transport Terms
• Typically, these never need to be adjusted. If you are having convergence issues, please contact the ANSYS
support team at support@ansys.com.
Spatially resolved data is written to every cell during the calculation. While the user specifies the fre-
quency, keep in mind that the amount of disk space required will go up with a higher frequency. Typ-
ically, solutions are written every 10 CA degrees and the User Defined outputs option is used to write
data out more frequently during important points in the cycle, such as injection, spark, combustion.
• – One File: All the data is written to a single file. This is not the desired option since the file will become
very large and this requires more time during file I/O and in rendering in the post-processor.
– File Size: This option allows you to specify a file size in megabytes for the maximum file size before another
file is written.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
32 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Automatic Mesh Generation Cases With Valve Motion
– Solution Count: This is the best option since you can control how many solutions are written to a single
file. A value of 1 means one solution per file. This is the preferred option.
• Spatially averaged data is data that is averaged over the domain. Since this is X-Y data, the data can be
written more frequently, such as every 1 CA degree, or even more frequently.
• Restart Data
• Restart points can be written at certain frequencies in Forte. It is suggested a restart be written on the last
simulation time-step, and also during the simulation prior to events occurring, such as IVO, injection, spark.
You specify the times to write out restart points.
b. Crevice width (for sector case, use between 1.0 and 1.5 mm, avoid a long skinny crevice)
• Adjust intake pressure and temperature to match pressure at SOI or spark timing (scale both P and T by
same %)
a. Check IVC mass to be sure A/F ratio computed mass is consistent with P & T for the IVC condition for
sector case.
b. IVC total mass can be computed from the ideal gas equation.
a. Be sure you compare apparent HRR and NOT chemical HRR with engine data; apparent HRR takes heat
losses (computed from P curve).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 33
Best Practices
b. You can adjust SOI +/−1CA deg. (typical uncertainty) to match the ignition timing.
b. Too much heat transfer through the walls, typically the liner.
6. Check emissions:
a. NOx is very important; if NOx is not predicted accurately, there is little confidence in other emissions,
such as soot.
• If the gap is too large, columns of cells will be created in the crevice, potentially connecting the ports
to the cylinder prematurely. See Figure 2.18: Gap too large (p. 35).
• If the gap is so small as to allow piston edges to bleed through the cylinder wall, the surface topology
becomes invalid and automatic mesh generation will fail, causing the run to abort. See Figure 2.19: Gap
too small (p. 36).
To avoid these issues, the rim of the piston should be resolved at a similar angular resolution as the
cylinder wall, and the gap between the piston and cylinder wall should be no more than 0.5% the cyl-
inder bore (ideally < 0.25%). See Figure 2.21: Mismatch in angular resolution causing self-intersec-
tions (p. 37).
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
34 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Two-stroke Engine Cases
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 35
Best Practices
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
36 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Two-stroke Engine Cases
Tip
Thus, the easiest way to create piston geometry compatible with two-stroke motion is to
generate the surface mesh with the piston in the BDC position and translate the piston to
TDC after importing the geometry into Forte.
Figure 2.22: BDC position translated to TDC (p. 38), demonstrates the geometry in the initial configuration
on the left, and after translating the piston to TDC on the right. The skirt mesh lines are shown. Note
that no intermediate vertices exist between TDC and BDC positions so this skirt mesh can compress
without upsetting the topology of the surface mesh.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 37
Best Practices
When defining the piston boundary condition, the Motion Type parameter should be set to Sliding
Interface. In the subpanel associated with this selection, select the outer cylinder wall and inner wall
that define the piston skirt as the stationary and sliding surfaces in the selection control. The piston
skirt should be given its own boundary condition separate from the piston, and it should be defined
with Wall Motion unchecked.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
38 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting Up Two-stroke Engine Cases
For example, the piston can be defined as a completely enclosed surface anchored at the bottom of
the cylinder (with a gap between piston bottom and lower with similar constraints as the skirt-liner gap
described previously), with the top of the piston defined as the sole moving surface, as shown in Fig-
ure 2.25: Geometry with enclosed piston (p. 40)
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 39
Best Practices
It’s also possible to define an entirely moveable piston, in which case all surfaces are defined as part of
the piston boundary condition.
Release 2019 R1 - © ANSYS, Inc. All rights reserved. - Contains proprietary and confidential information