Product Information
Horsepower: 3/4 – 6
Temperature Applications: Low/Medium/High
Refrigerants: R-134a, R-22, R-404A, R-407A,
R-407C, R-448A, R-449A, R-507
Installation Applications: A variety of applications including
walk-in boxes, display cases,
island cases, soft serve
Nomenclature • Welded Condensing Units
Compressor Motor Types
X X X X - XXXX - X X X - X X X
Condensing Type of Design Code Comp. Motor Rating Electrical Codes
Unit Air Cooled Steel Base A
60 Hz. 50 Hz. Code
Family Air Cooled Copevap Base E/P Nominal
Code
Series HP 115-1 100-1 A
Narrow Air Cooled Copevap T
230-1 - B
Water Cooled Steel Base W 1/2 0050 Compressor Motor Protection 208/230-3 200/220-3 C
Custom Base C 3/4 0075 460-3 - D
1 0100 Type Protection Code 575-3 - E
Discus D
1-1/2 0150 - 230-1 G
2 0200 External Inherent Protection-
A - 380/420-3 M
Refrigerant Code 3 0300 One Protector (Line Break)
208/230-1 200-1 V
R404A/507 J/4 4 0400
5 0500 Internal Inherent Protection – - 220-3 W
R134a T/2 F - 220/240-1 Z
6 0600 One Protector (Line Break)
R12 B 7-1/2 0750 Note: When applicable, specific 50
9 0900 Internal Thermal Protection –
R22 C/3/M Hz ratings (not necessarily identical
10 1000 Electronic Sensors; and S to typical shown above) will be shown
Multiple F Control Module External
15 1500 as alternate on 60 Hz rated models.
R22/407C G
R22 9 Note: Left position may
be a letter indicating a
R134a/404A/22 N
revision change
R134a/404A P
R404A/22 8
Dimensional Drawings
Copeland Scroll™ outdoor condensing units
Features Benefits
Reliability
Copeland Scroll Compressor
High Energy Efficiency
Variable Speed Fan Motor
Low Sound & Vibration
Faster Troubleshooting
Advanced Diagnostics and Protection Features
Warranty Reduction
Factory Installed EK Filter Drier and Fewer Leaks, Reduced Callbacks, Lower Installation Costs,
HMI Moisture Indicator Increased Equipment Reliability, Lower Warranty
Sound Data
Model dBa* Sound pressure values are 10 feet from the unit at 25°F evap for MT and -10°F evap for LT at 90°F
Single fan 55 ambient. A sound reduction of up to 3 dBA will occur in ambient temperatures below 70°F. This
MED
data is typical of “free field” conditions for horizontal air cooled condensing units and may vary
TEMP Double fan 58 depending on the condensing unit installation. There are many factors that affect the sound
LOW Single fan 53 reading of a condensing unit such as unit mounting, reflecting walls, background noise and
TEMP Double fan 59 operating condition.
Two-Way Communication
Vapor Injection (EVI)
Receiver W/ Valve
Crankcase Heater
Pressure Controls
Demand Cooling
Defrost Control
Suction Valve
Accumulator
Liquid Valve
Recognized
Filter Drier
Listed
XFAL
081 X X X X XFAP X X X X X X X X X X X
Only
MT Indoor AWEF
Base Model
R-134a R-22 R-404A R-407A R-407C R-448A R-449A
XFAM-008Z 7.74 - 7.79 7.45 7.33 7.47 7.49
XFAM-010Z 7.88 - 7.84 7.59 7.34 7.38 7.39
XFAM-012Z 8.37 - 8.12 7.80 7.67 7.55 7.61
XFAM/P-015Z 7.23 7.84 7.28 7.55 6.76 6.75 6.75
XFAM/P-017Z 7.51 7.84 7.40 7.55 7.00 6.99 6.99
XFAM-020Z 7.45 7.84 7.57 7.39 6.87 6.75 6.78
XFAM/P-022Z 7.74 7.73 7.49 7.36 7.01 6.94 6.97
XFAM-025Z 7.75 7.63 7.46 7.53 6.99 6.89 6.89
XFAM/P-030Z 8.31 8.07 7.24 7.49 7.43 7.08 7.08
XFAM-033Z 8.34 8.01 7.21 7.32 7.40 6.86 6.84
XFAM-037Z 8.29 7.85 7.00 7.18 7.28 7.06 7.02
XFAM/P-045Z 8.00 7.85 7.09 7.05 7.20 7.09 7.08
XFAM/P-050Z 7.98 7.54 6.63 6.92 6.97 7.11 7.11
XFAM/P-060Z 7.96 7.46 6.88 7.12 7.06 6.98 6.98
MT Outdoor AWEF (Factory Settings MT Outdoor AWEF (With 50°F Min. Cond. Temp. Settings)
Base Model
R-134a R-22 R-404A R-407A R-407C R-448A R-449A R-134a R-22 R-404A R-407A R-407C R-448A R-449A
9.00 - 10.59 10.01 9.94 10.00 10.00 9.00 - 11.53 10.55 10.50 11.00 11.00
9.00 - 10.84 10.39 10.34 10.00 10.00 9.00 - 11.88 11.02 10.93 11.00 11.00
10.00 - 11.32 10.37 11.00 10.00 10.00 10.00 - 12.31 10.86 11.00 11.00 11.00
8.87 9.79 9.78 9.82 9.66 9.07 9.11 8.87 10.32 10.16 10.28 9.99 9.45 9.52 9.54
9.29 9.97 10.08 9.98 10.01 9.51 9.51 9.29 10.45 10.42 10.44 10.36 10.08 10.08 10.08
9.36 10.07 10.42 9.89 9.94 9.38 9.38 9.36 10.51 10.92 10.35 10.26 9.76 9.77 10.23
10.08 9.87 10.43 10.19 10.22 9.66 9.68 10.51 9.87 10.78 10.89 10.53 10.13 10.16 10.76
9.99 10.07 10.61 10.27 10.22 9.69 9.69 9.99 10.49 11.12 10.60 10.54 10.06 10.06 10.66
10.93 10.81 10.43 10.50 10.96 10.24 10.23 10.93 11.22 10.74 10.82 11.30 10.58 10.58 9.25
11.06 10.87 10.49 10.55 10.95 10.05 10.05 11.06 11.24 10.90 10.96 11.30 10.23 10.23 9.54
11.06 10.79 10.36 10.33 10.86 10.41 10.41 11.06 11.06 10.63 10.55 11.19 10.54 10.54
10.46 10.51 10.26 9.93 10.57 10.21 10.21 10.46 10.90 10.52 10.21 10.90 10.49 10.49
9.59 9.22 8.71 8.93 9.07 9.31 9.28 9.59 9.22 8.68 9.16 9.27 9.25 9.25
9.90 9.45 9.36 9.43 9.42 9.48 9.48 9.90 9.45 9.33 9.74 9.62 9.56 9.54
This refrigeration system is designed and certified for use in walk-in cooler applications.
AE Bulletins HVACR Fault Finder Emerson X-Check™ HVAC Check & Charge Emerson e-Saver™ Copeland™ Select
WRMobile Vilter™ Docs Copeland™ Mobile Copeland X-Ref™ Emerson PTPro™ ProAct Alerts
Climate.Emerson.com
Register for
more product
information
Emerson.com
2011DS-4_X-Line R4 (6/18) Emerson and Copeland Scroll and CoreSense are trademarks of Emerson Electric Co. or one of its affiliated companies.
©2018 Emerson Climate Technologies, Inc. All rights reserved.