Shirley Lu
2.77 Spring 2019
Stay within time Simple and Quick DFM and DFA, Hard to fabricate Design with
limit Fabrication: availability of few components, use available
machines parts (syringe body)
- Waterjet vs.
Bandsaw + DrillPress (FUNdaMENTALS,
machine capabilities)
Easy to quantify Force measurable via Force Balance Very high or low forces difficult
(to close design spring scale to measure Calculate
Design for easy expected values, tune design
loop)
scale attachment parameters
1
Design Sketches / Concepts
3
Analysis
Critical Analysis: Force and moment balance to determine the force required to pull plunger from a
set distance off-axis.
4
Analysis (cont.)
Critical Analysis: Force and moment balance to determine the force applied (F_a) required to pull
plunger from a set distance off-axis (c).
5
Plunger Top – holes
DETAILED DESIGN drilled at set distances
from centerline for
fishing line to loop
Pistons – sliding component through, for ease of
subject to wedging; the two attaching spring scale
threaded pistons are to measure pull force
adjustable to change the
width to diameter ratio
Syringe – 150mL
syringe that provides
Stand – for ease of testing, the channel for pistons
maintaining syringe in to slide
vertical orientation
6
MANUFACTURING
Simple fabrication while
effectively demonstrating FPGA
principles
- Stock for piston disks was
chosen to fit syringe diameter
- Only operations were to
drill tap hole, cut to length,
and tap holes; all done in
single (lathe) setup
- Stand 3D printed for ease of
testing and repeatable Most Critical Part: Plunger Top
measurements - Attachment for testing off-center pull force
- All other components are - Simple + quick fabrication: bandsaw, drill press
standard fasteners
7
MEASUREMENTS
Measured vs Theory
Fa
c
8
SUMMARY
TIME BUDGET
- General trend in measured data matches
expected values Category Time [hours]
- Sources of error: Design (Individual + Peer Review + Final) 3
- Larger errors seen for the 0.75 width to CAD 2
diameter ratio trials likely due to the Analysis 4.5
compliant nature of the tape used to Fabrication + Assembly 6
increase the diameter of the piston Testing 2.5
which prevented the piston from
Documentation 3
becoming fully “wedged” as expected
Total 21