Professional Documents
Culture Documents
OCS Technical Manual PDF
OCS Technical Manual PDF
Technical Manual
Content
1. Display.....................................................................................1
Message ...............................................................................1
2. Scale Configuration................................................................1
Auto-Zero range.................................................................2
Manual-Zero range ............................................................2
Zero-Tracking range ..........................................................2
Gravity.................................................................................3
User Unit .............................................................................3
3. Calibration...............................................................................4
System Unit.........................................................................5
Calibration Gravity ............................................................5
Max. Cap. ............................................................................6
Zero Detection ....................................................................6
Load1 Detection..................................................................6
Load2 Detection..................................................................7
Load3 Detection..................................................................7
1. Display
Message
message stand for note
Password password mode
SCALE scale configuration
Auto Zero range Auto-Zero range
Manual Zero range Manual-Zero range
Zero Track range Zero-Tracking range
Gravity gravity of acceleration
CaLiBRaTion calibration
LOAD0 load0 detection
LOAD1 load1 detection
LOAD2 load2 detection
LOAD3 load3 detection
User unit User Unit
Full Scale Max. Cap.
2. Scale Configuration
Press or twice, enter Password mode.
Scale displays 。
Press or , and , modify digital. Press or
, and , move digital. Input Scale Configuration password.
Press or , confirm input, enter Scale Configuration.
Scale displays 。
Parameters in Scale Configuration are closely related to scale’s
metrology performance. It is NOT recommended to change any
Page 1 of 8
High Resolution Digital Crane Scale Technical Manual
Auto-Zero range
Scale displays Auto-Zero range, e.g., indicating
20% F.S..
Upon boot-up, scale automatically zero.
Press or , and , change Auto-Zero range.
Press or , exit without saving. Press or ,
exit and save.
Auto-Zero range can be set to : 0%(disabled), 2%, 3%, 4%, 10%,
20%, 100% F.S..
Press or , enter Manual-Zero range.
Manual-Zero range
Scale displays Manual-Zero range, e.g., indicating
4% F.S..
Zero is allowed, only when weight is within Manual-Zero
range.
Press or , and , change Manual-Zero range.
Press or , exit without saving. Press or ,
exit and save.
Manual-Zero range can be set to : 0%(disabled), 2%, 3%, 4%,
10%, 20%, 100% F.S..
Press or , enter Zero-Tracking range.
Zero-Tracking range
Scale displays Zero-Tracking range, e.g., indicating
0.5e.
Page 2 of 8
High Resolution Digital Crane Scale Technical Manual
Gravity
Scale displays Gravity, e.g., indicating g is 9.794.
Adjust Gravity, only when scale is used in a place where
acceleration of gravity is greatly different from the place where
it is calibrated.
Press or , and , modify digital. Press or
, and , move digital. Input Gravity.
Press or , exit without saving. Press or ,
exit and save.
Gravity range can be set from 9.700 to 9.899.
Press or , enter User Unit.
User Unit
Scale displays User Unit, e.g., indicating user unit is
set to 1.000.
User Unit is a named unit which is usually used in user’s region,
but not included in scale by default, like kg, lb, etc. It is a ratio to
System Unit. For example, if User Unit is set to 1.234 and
System Unit is kg, then after switching to User Unit, scale
calculates weight (1000kg), and displays the calculated value
(1234usr).
Page 3 of 8
High Resolution Digital Crane Scale Technical Manual
3. Calibration
Press or twice, enter Password mode.
Scale displays 。
Press or , and , modify digital. Press or
, and , move digital. Input Calibration password.
Press or , confirm input, enter Calibration.
Scale displays 。
It is NOT recommended to enter Calibration unless you are
authorized from your local representative with correct
password.
Page 4 of 8
High Resolution Digital Crane Scale Technical Manual
System Unit
Scale displays System Unit, e.g., indicating system
unit is kg.
Press or , and , change System Unit.
Press or , exit without saving. Press or ,
exit and save.
System Unit can be set to: kg and lb.
Press or , enter Calibration Gravity.
Calibration Gravity
Scale displays Calibration Gravity, e.g., indicating
Calibration Gravity g = 9.794.
Press or , and , modify digital. Press or
, and , move digital. Input Calibration Gravity.
Press or , exit without saving. Press or ,
exit and save.
Calibration Gravity range can be set from 9.700 to 9.899.
Press or , enter Max. Cap..
Page 5 of 8
High Resolution Digital Crane Scale Technical Manual
Max. Cap.
Scale displays Max. Cap., e.g., indicating Max. Cap.
is 3t.
Press or , and , change Max. Cap..
Press or , exit without saving. Press or ,
exit and save.
Do NOT attempt to set Max. Cap. greater than scale’s actual
capacity. Overloading causes severe harm to scale, and is very
dangerous.
Press or , enter Zero Detection.
Zero Detection
Scale displays .
Keep scale no load, press or , start weight detection.
Message displays. After detection is finished, scale
automatically enter Load1 Detection.
Load1 Detection
Scale displays .
Load standard weight, press or , go to weight input
interface.
Scale displays “00000”, waiting for user input.
Press or , and , modify digital. Press or
, and , move digital. Input Load1 weight.
Weight must exceed 0, otherwise displays.
Weight must be lighter than 100% F.S., otherwise
displays.
If weight is equal to 100% F.S., scale automatically save and exit
Calibration.
Page 6 of 8
High Resolution Digital Crane Scale Technical Manual
Load2 Detection
Scale displays .
Press or , skip Load2 Detection, save and exit
Calibration.
In most cases, one load calibration is enough. Calibrating scale
with more than one weight is usually required only when scale’s
linearity performance is not desired.
Load standard weight, press or , go to weight input
interface.
Scale displays “00000”, waiting for user input.
Press or , and , modify digital. Press or
, and , move digital. Input Load2 weight.
Weight must be lighter than 100% F.S., otherwise
displays.
If weight is equal to 100% F.S., scale automatically save and exit
Calibration.
It is recommended to use weight that is equal to scale’s Max.
Cap. to calibrate scale.
Keep scale stable, press or , confirm.
Message displays. After detection is finished, scale
automatically enters Load3 Detection.
Load3 Detection
Scale displays .
Page 7 of 8
High Resolution Digital Crane Scale Technical Manual
Page 8 of 8