User Guide
User Guide
Issue 05
Date 2009-11-12
Part Number 7110002
Contents
1 Basic Information.......................................................................................................................1-1
1.1 Basic Components.........................................................................................................................................1-1
1.2 Entering Text .................................................................................................................................................1-2
1.3 Powering on ..................................................................................................................................................1-2
1.4 Basic Settings ................................................................................................................................................1-3
Safety Precautions
Before you install and use the device, read the following safety precautions carefully to avoid
human injury, device damage, data loss, decrease of the device performance, and other
unexpected damages.
If the device is not going to be used for a long time, remove the batteries of the remote
control.
If the device is not going to be used for a long time, remove the batteries of the remote control.
1 Basic Information
The HUAWEI 9000 HD Video Terminal (hereinafter referred to as the terminal) is a new-
generation high definition video terminal launched by Huawei Technologies Co., Ltd.
(hereinafter referred to as Huawei). The HUAWEI 9000 incorporates the traditional features
of Huawei videoconferencing products, such as SiteCall, H.239 dual stream, conference
control, and Continuous Presence (CP). It also adds the high definition (HD) video processing
ability to enhance the on-spot experience of users and provides quick videoconferencing
services.
Name Description
Main set It includes the audio and video processing unit, audio interface,
video interface, control interface, and network interface.
Remote control It is used to control the terminal.
Power module/power It is used to connect to the power socket.
cable
DVI-SXGA cable z Connect to the DVI-I output interface and the VGA input
interface of the projector.
z Connect to the DVI-I input interface and the VGA output
interface of the PC.
DVI-HDMI cable z Connect the DVI output interface of the terminal to the HDMI
input interface of the display device.
z Connect the HDMI output interface of the video player to the
DVI input interface of the terminal.
DVI-YPrPb z Connect the DVI-I output interface of the terminal to the
HDMI input interface of the display device.
z Connect the DVI-I input interface of the terminal to the YPrPb
output interface of the video output device.
Name Description
Audio and video cable Connect the AUDIO OUT MAIN interface to the audio input
interface of the HD television. Ensure that the color of the
interface is the same as that of the connector.
Network cable It is used to connect to the LAN.
Key Function
1.3 Powering on
Check whether the power cable and the power module are connected to the corresponding
devices properly.
Ensure that:
When the power cable is connected to the terminal and the green indicator of the power
adapter is on, it indicates that the terminal is connected to the power supply.
To power on the ViewPoint 9039, do as follows:
On the Wizard screen, you can set the network parameters, camera parameters, and basic
information such as the site name and language.
To display the Wizard screen, do as follows:
z Select System Settings form the shortcut icons on the home screen, and then choose
Wizard from the displayed menu.
z Choose Main Menu > System Settings > Wizard.
You can use the terminal to make point-to-point calls and answer incoming calls.
z You can access the Call screen by pressing any number key on the remote control. Then you can
make a call.
z On the Call screen, you can select to display the Directory screen or select to display the
Call Record screen. On the Directory or Call Record screen, you can select a site, and then make a
call.
Step 2 Select , select Outgoing Calls, Answered Calls, or Missed Calls, and then select the site
to be called.
Step 3 Select Call to display the Call screen.
The information of the site to be called appears in the corresponding drop-down combo box.
Step 4 Select Call.
----End
Step 1 Press DIRECTORY on the remote control to display the Contacts screen.
Step 2 Select the site to be called.
Step 3 Select Call to display the Call screen.
The information of the site to be called appears in the corresponding drop-down combo box.
Step 4 Select Call.
----End
3 Holding a Conference
You can use the terminal to initiate a multipoint conference. The conference can be a dual-
stream conference.
An H.239 dual-stream conference means that both the main stream and the H.239 Content can
be transmitted in the conference. You can transmit two channels of video sources of the local
end or view two channels of videos of the remote end at the same time.
Step 1 Press SOURCE , On the Main screen, select the desired main video.
Step 2 Press DISPLAY , to select the output content for the connected monitor.
----End
z If you need to hold a dual-stream conference, configure the H.239 Content source when configuring
the video sources.
z During a conference, you can select the video sources of the main stream and the H.239 Content
dynamically.
Step 1 Press CONFERENCE on the remote control to display the SiteCall screen.
Step 2 Enter a conference name in the corresponding drop-down combo box.
Step 3 Add the sites to be called.
z Enter the name (You need to predefine this site in the directory), number, or IP address of
the site to be called in the corresponding text box. If multiple sites are to be called, use
commas to separate the names, numbers, or IP addresses of the sites.
z To add sites from the directory, select Add from Directory.
Step 4 Set the conference rate, and then specify whether to enable the H.239 Content function.
If the site rate is lower than the conference rate, the corresponding site cannot join the conference.
Step 5 Select Advance, and then set the conference parameters for the SiteCall.
Parameter Description
H.239 mode To hold a dual-stream conference, you can set this parameter to
Presentation or Live.
Continuous It is used to specify the maximum number of site videos that can be
presence viewed by the joined sites.
After the continuous presence is broadcasted, the joined sites can view the
videos of multiple sites at the same time.
If this parameter is set to OFF, the conference does not support the
continuous presence.
Conference The password used to access the conference. This parameter provides two
Password functions:
z Conference control password: After a conference is successfully held,
the joined IP sites must enter this password to obtain the right to control
this conference when requesting Chair.
z Authentication conference password: Anonymous sites must enter this
password to join in an authentication conference.
IP/PSTN The number of IP/PSTN anonymous sites that are allowed to join in the
anonymous conference.
sites z If this parameter is set to 5, five such kind of anonymous sites are
allowed to join in the conference.
z If this parameter is set to 0, no anonymous sites are allowed to join in
the conference.
H.235 security It is used to set whether to use the H.235 security protocol to encrypt the
conference media streams and call signaling.
z Non-security: If this option is selected, all kinds of information in a
conference are not encrypted.
z Media security: If this option is selected, the media stream is
encrypted.
Parameter Description
Payment side It is used to determine the payment party of the current conference.
z Local: The current conference is paid by the local site.
z Other account: The current conference is paid by another account. You
need to enter Account and Password.
Step 6 Confirm the settings and return to the SiteCall screen. Then select SiteCall.
----End
Step 1 Press CONFERENCE on the remote control to display the SiteCall screen.
Step 2 Select Advance to display the Conference Parameters screen.
Step 3 Select Enable MiniMCU.
The built-in mini MCU processes conference data like the MCU on a videoconferencing
network. If a tick (√) is displayed in the check box, it indicates that the option is selected.
Step 4 Select OK to display the SiteCall screen.
Step 5 Add the sites to join the conference, set the conference rate, and specify whether to enable
H.239.
Step 6 Select SiteCall.
----End
Step 2 Make a second point-to-point call to the second site on the terminal with the mini MCU
function.
A multipoint conference that contains three sites is held.
Step 3 Repeat Step 2 to make point-to-point calls to the other sites.
----End
If a site to be called is defined in the directory of a terminal with the mini MCU function, you can also
call this site through the site number or the site name on the terminal.
You can send the H.239 Content by pressing the CONTENT key. You can stop
transmitting or resend the H.239 Content by pressing the key.
Use… To…
Use… To…
Roll Call Let one of the sites take the floor. The microphones of other sites are
muted. Other sites can view the roll called site.
Request Floor List Display all the sites that are requesting floor.
Free Talk Cancel operations such as broadcast site, mute speaker, mute
microphone, and roll call.
Call Site Add a new site to the conference or allow a site to join the
conference.
Call All Sites Call the absent sites in the site list.
Hang up Disconnect a present site so that it is removed from the conference.
Extend Conference Extend a conference.
End Conference End the current conference.
Voice Activation Broadcast the video of a site whose volume is the highest among all
the sites in the discussion.
Mute Speaker Close the audio output of the site. You cannot hear any sound from
other sites.
Mute Mic Close the audio input of the site. Other sites cannot hear any sound
from the local site.
Set CP Show Continuous Presence to view multiple sites at the same time.
Release H.239 During a H.239 dual-stream conference in Presentation mode, the
Token chair site releases the H.239 token. Without the H.239 token, the site
stops sending the H.239 Content.
H.239 Lock Limit the rights for sending the H.239 Content to a site or restrict the
rights for sending the H.239 Content during a conference.
Deprive Chair Become the chair site. This function is available only when you hold
a multipoint conference by sitecall and you are pay party.
Enable Chair After the Enable Chair operation is performed on the terminal with
the mini MCU function, all the sites in the conference can request for
the chair token.
Disable Chair After the Disable Chair operation is performed, no chair site exists
in the conference. If a chair site exists, after this operation is
performed on the terminal with the mini MCU function, the site is
deprived of the chair token.
Note: When a conference is held by using the mini MCU function, the Enable Chair and Disable Chair
operations can be performed only on a terminal with the mini MCU function.
Step 2 Select New, Edit, or select a caption and then press OK to display the Caption
Properties screen for editing a caption.
Step 3 Set the name and display effect of the caption.
Step 4 Select Edit to enter the text contents of the caption. Press # to switch between text
input modes.
Press OK to move the cursor from one line to another. Press PAGE UP
When you complete editing a caption, you can select Send to send the caption immediately.
To stop sending the caption, select Stop Sending.
Hiding Picture
During a conference, if you do not want to be seen by the remote site, you can hide your
picture. Choose Main Menu > Conference Service > Hide Picture to hide your video.
To access the Adjust Camera screen, you can press ZOOM or , or press OK
when the main menu is hidden.
z Preset position: For details about how to preset a camera position, see section 4.2.2
"Presetting Camera Positions."
z Focus: You can adjust the focus.
z Return: You can exit the Camera Control screen.
Step 2 On the Camera Control screen, select Adjust Camera, and then press F1 to switch
between the local camera and the remote camera.
----End
Step 2 Press MENU to display the navigation pane of the home screen.
Step 3 Select the Adjust Camera icon.
The Adjust Camera screen appears.
z Select Adjust Camera. Then you can perform the following operations:
− Move the camera towards any of the four directions by pressing the corresponding
arrow key on .
z Select Focus, select Long focus, Auto focus, or Short focus by pressing , and
To be simple, ① stands for the local main stream; ② stands for the local H.239 Content; ③
stands for the remote main stream; ④ stands for the remote H.239 Content.
The following table lists the available contents that are output through the video output
interfaces of the ViewPoint 9039, ViewPoint 9036, ViewPoint 9033, and ViewPoint 9035.
The following table lists the available contents that are output through the video output
interfaces of the ViewPoint 9030.
The following table lists the available contents that are output through the video output
interfaces of the ViewPoint 9039S and HUAWEI VP9039A.
The following table lists the available contents that are output through the video output
interfaces of the HUAWEI VP9035A.
According to the above table and your requirements, you can select which video to be output
through HD OUT 1, HD OUT 2, HD OUT 3, and SDI OUT respectively. Choosing Main
Menu > Conference Service > Manage Video Output. Then select available video to be
output through the three interfaces.
To show the desktop of a computer, ensure that the resolution and refresh rate of the computer
are supported by the terminal. You can set these parameters by choosing Main Menu >
System Settings > Video Output.
After you adjust the video effects, the adjustment is applicable to only the local SD main-stream video.