Appendix C

Dynamic Cone Penetrometer Test Results


DYNAMIC CONE PENETROMETER TEST

LOCATIION : Plot No E/0/6, Ndola Central Corner of Presidents and Kanongesha Avenue

DATE OF TESTING: 21/08/2015

OPERATOR: H.MUSHOTA

TRIAL PIT 1

Depth (mm) Number of Blows


300 16
600 19
900 15

TRIAL PIT 2

Depth (mm) Number of Blows


300 15
600 16
900 14

TRIAL PIT 3

Depth (mm) Number of Blows


300 20
600 15
900 13