NET ZERO ENERGY BUILDINGS

Introduction
Within This Page

 Introduction
 Description
 Application
 Relevant Codes and Standards
 Additional Resources

Amid growing concerns about rising energy prices, energy independence, and the impact of
climate change, statistics show buildings to be the primary energy consumer in the U.S. This
fact underscores the importance of targeting building energy use as a key to decreasing the
nation's energy consumption. The building sector can significantly reduce energy use by
incorporating energy-efficient strategies into the design, construction, and operation of new
buildings and undertaking retrofits to improve the efficiency of existing buildings. It can
further reduce dependence on fossil fuel derived energy by increasing use of on-site and off-
site renewable energy sources.

The concept of a Net Zero Energy Building (NZEB), one which produces as much energy as
it uses over the course of a year, recently has been evolving from research to reality.
Currently, there are only a small number of highly efficient buildings that meet the criteria to
be called "Net Zero". As a result of advances in construction technologies, renewable energy
systems, and academic research, creating Net Zero Energy buildings is becoming more and
more feasible.

While the exact definitions of metrics for "net zero energy" vary (this is discussed below),
most agree that Net Zero Energy Buildings combine:

 Exemplary building design to minimize energy requirements


 Renewable energy systems that meet these reduced energy needs.

Description
Definitions

As the "zero energy" and "net zero energy" concepts are relatively new, there are not yet
definitive, widely accepted zero-energy metrics. The Department of Energy (DOE) and the
National Renewable Energy Laboratory (NREL) have spearheaded much of the work on net
zero energy buildings to date. NREL presents several definitions for "net zero energy", and
they encourage building designers, owners, and operators to select the metric that best fits
their project. The NREL publication Zero Energy Buildings: A Critical Look at the
Definition explores definitions in detail, and it suggests four ways in which net zero energy
may be defined:

 Net Zero Site Energy


 Net Zero Source Energy
 Net Zero Energy Costs
 Net Zero Energy Emissions

Site Energy refers to the energy consumed and generated at a site (e.g. a building), regardless
of where or how that energy originated. In a net zero site energy building, for every unit of
energy the building consumes over a year, it must generate a unit of energy.

Source Energy refers to primary energy needed to extract and deliver energy to a site,
including the energy that may be lost or wasted in the process of generation, transmission and
distribution. For example, a coal-burning power plant may generate 1 Joule of electricity for
every 3 Joules of energy in the coal consumed. If natural gas is used at a site, for every 20
Joules consumed, 1 Joule may be needed to extract and distribute the gas to the site. Metrics
for net zero source energy buildings account for these factors, though exact metrics can vary
depending on site and utility factors.

Net Zero Energy Cost is perhaps the simplest metric to use: it means that the building has an
energy utility bill of $0 over the course of a year. In some cases, building owners or operators
may take advantage of selling Renewable Energy Credits (RECs) from on-site renewable
generation.

Many conventional energy sources result in emissions of carbon dioxide, nitrogen oxides,
sulfur dioxide, etc. A Net Zero Energy Emissions building either uses no energy which results
in emissions or offsets the emissions by exporting emissions-free energy (typically from on-
site renewable energy systems).

Grid Connection and Net Zero

Most Net Zero Energy Buildings are still connected to the electric grid, allowing for the
electricity produced from traditional energy sources (natural gas, electric, etc.) to be used
when renewable energy generation cannot meet the building's energy load. When,
conversely, on-site energy generation exceeds the building energy requirements, the surplus
energy should be exported back to the utility grid, where allowed by law. The excess energy
production offsets later periods of excess demand, resulting in a net energy consumption of
zero. Due to current technology and cost limitations associated with energy storage, grid
connection is usually necessary to enable the Net Zero Energy balance. Differences in how
utilities and jurisdictions address payment for energy that is exported from the building into
the grid can impact project economics and should be carefully evaluated.

Energy Efficiency

Regardless of the definition or metric used for a Net Zero Energy Building, minimizing the
energy use through efficient building design should be a fundamental design criterion and the
highest priority of all NZEB projects. Energy efficiency is generally the most cost-effective
strategy with the highest return on investment, and maximizing efficiency opportunities
before developing renewable energy plans will minimize the cost of the renewable energy
projects needed. Using advanced energy analysis tools, design teams can optimize efficient
designs and technologies.

Energy efficiency measures include design strategies and features that reduce the demand-
side loads such as high-performance envelopes, air barrier systems, daylighting, sun control
and shading devices, careful selection of windows and glazing, passive solar heating, natural
ventilation, and water conservation.

Once building loads are reduced, the loads should be met with efficient equipment and
systems. This may include energy efficient lighting, electric lighting controls, high-
performance HVAC, and geothermal heat pumps. Energy conversion devices such as
combined heat and power systems, fuel cells, and microturbines do not generate renewable
energy. Instead, they convert fossils fuel energy into heat and electricity and are can be
considered energy efficiency strategies.

Renewable Energy

On-Site Renewable Energy

A photovoltaic array

Once efficiency measures have been incorporated, the remaining energy needs can be met
using renewable energy technologies. Common on-site electricity generation strategies
include photovoltaics (PV), solar water heating, and wind turbines.

Renewable, on-site thermal energy can sometimes be provided by effective use of biomass.
Wood, wood pellets, agricultural waste, and similar products can be burned on-site to provide
space heating, service water heating, etc. Biofuels, such as biodiesel, may also be used in
conjunction with conventional fossil fuels to meet thermal loads. More background on
biomass is available in the Alternative Energy page.
Priority should be given to renewable approaches that are readily-available, replicable, and
most cost-effective. System maintenance must also be given consideration to over time. Life-
cycle cost analysis should be used to evaluate the economic merits of various systems over
their usable lifetimes.

Off-Site Renewable Energy

Wind turbines

Depending on the NZE metric and guidelines used, buildings may be permitted to use energy
generated off-site to offset energy used in a building. If space is limited, a facility owner may
install dedicated wind turbines, solar collectors, etc. at a separate location. Most often,
however, credit for off-site renewable generation is gained by purchasing renewable energy
credits (RECs).

RECs are available from many renewable energy technologies. Large, utility-scale wind
farms, solar plants, geothermal plants, and hydropower facilities generate electricity without
using fossil fuels or primary energy. The costs of constructing and operating these generation
facilities are often paid for by selling the "credit" for generating energy renewably (as well as
selling the energy itself). The structure and market for RECs is evolving and it varies
regionally.

Executive Order 13514 outlines allowable renewable energy strategies which include:
"energy produced by solar, wind, biomass, landfill gas, ocean (including tidal, wave, current,
and thermal), geothermal, municipal solid waste, or new hydroelectric generation capacity
achieved from increased efficiency or additions of new capacity at an existing hydroelectric
project".

Federal Net Zero Energy Building Goals


Executive Order 13514, signed in October 2009, requires all new Federal buildings that are
entering the planning process in 2020 or thereafter be "designed to achieve zero-net-energy
by 2030". "In addition, the Executive Order requires at least 15% of existing buildings (over
5,000 gross square feet) meet the Guiding Principles for Federal Leadership in High
Performance and Sustainable Buildings by 2015, with annual progress towards 100%
conformance".

Two milestones for NZEB have also been defined by the Department of Energy (DOE) for
residential and commercial buildings. The priority is to create systems integration solutions
that will enable:

1. Marketable Net Zero Energy Homes by the year 2020


2. Commercial Net Zero Energy Buildings at low incremental cost by the year 2025.

These objectives align with the Energy Independence and Security Act of 2007, which calls
for a 100% reduction in fossil-fuel energy use (relative to 2003 levels) for new Federal
buildings and major renovations by 2030.

The Building Technologies Office (BTO), created under DOE's Office of Energy Efficiency
and Renewable Energy, focuses on improving the efficiency of buildings and their associated
equipment, components, and systems. The BTO supports research and development
activities, tools, guidelines, training, and technical resources to improve new and existing
building performance in both the Commercial and Residential sectors. A Multi-Year Program
Plan for the BTO outlines the projected activities and near-term goals of the BTO, including
both commercial and residential building research focused on achieving long-term Net Zero
goals.

The Net Zero Energy Commercial Building Initiative (CBI) aims to achieve marketable net
zero energy buildings by 2025 through an array of public and private partnerships to advance
the development and adoption of high-performance buildings.

Parallel residential initiatives are conducted under the Building America Program, which has
demonstrated market transformation through research conducted under the BTP. (See the
Additional Resources section for links to reports, codes, design guides, software tools, and
other key resources to achieve energy reduction and net zero energy strategies available
through DOE.)

Application
Net Zero Energy Building principles can be applied to most types of projects, including
residential, industrial, and commercial buildings in both new construction and existing
buildings. A growing number of projects have been designed and constructed across the
various market sectors and climate zones. Several links to DOE's Commercial project
resources are provided below, including:

 Commercial Buildings Integration Program


 Commercial Buildings Partnerships
 Better Buidings Alliances
 High-Performance Buildings Database
 Zero Energy Buildings

Commercial Examples

NREL Research Support Facilities Building

In June 2010, the National Renewable Energy Laboratory (NREL) completed the
construction of Phase 1 of their Research and Support Facility (RSF). Located in Golden,
Colorado, the RSF is currently the largest NZEB in the U.S. The 220,000 sq. ft. project
achieved the Net Zero site energy goal through a performance-based design/build process.
Numerous energy efficiency strategies were implemented including incorporating advanced
heat recovery technologies that were developed and designed by researchers at the Lab and
installing 1.6 megawatts of photovoltaic power on the campus through a Power Purchase
Agreement. Additionally, daylighting, natural ventilation, and a next-generation, energy
efficient data center are among the other energy features of the building.
Oberlin College Lewis Center, Oberlin, Ohio
Photo credit: John Petersen, Oberlin College

The Adam Joseph Lewis Center for Environmental Studies, located on the Oberlin College
campus in Oberlin, Ohio, is another example of a Net Zero Energy site energy building. The
Center was explicitly conceived as an integrated building-landscape system that would
continue to change and to improve in performance over time. It houses classroom and office
space, an auditorium, a small environmental studies library and resource center, a
wastewater-purification system in a greenhouse, and an open atrium. The Lewis Center is an
all-electric building and was designed with maximum energy efficiency in mind. The Center
generates its own on-site electricity through a roof mounted 60 kW PV system and a 100 kW
PV system located over the parking lot. The Center is "grid-interconnected", meaning that
when the solar panels produce more electricity than the Center consumes, electricity is
exported to the City of Oberlin. Since the parking lot PV array was added in May of 2006, the
Center has been a net exporter of electricity - producing more electricity on an annual basis
than it consumes. Solar electricity production is coupled with energy efficient lighting,
heating, and appliances to minimize negative environmental impact.
The Wayne N. Aspinall Federal Building and U.S. Courthouse in Grand Junction, CO, which
GSA is aiming to turn into a Net-Zero Energy usage historic building.
Photo Credit: GSA

In February 2011, GSA announced its plan to renovate the 92 year-old Wayne Aspinall
Federal Building and U.S. Courthouse and make it the country's first Net Zero site energy
historic building. The GSA will partner with local Grand Junction, Colorado businesses to
maintain the historic features of the building while investing in sustainable technologies that
will make it one of the most energy efficient buildings in the country. GSA will install a
geothermal heating and cooling system and a solar panel array that will generate enough
energy to cover the electricity demand of the building. Any excess energy produced will be
exported to the local energy grid. In addition, the building will feature lighting fixtures that
adjust in response to natural lighting levels and storm windows with a solar film covering that
will reduce the demand on heating and cooling. GSA plans to complete the project by
January 2013.
Residential Examples

Refer to Building America for additional case studies of residential projects.

Completed NREL/Habitat Zero Energy Home


Photo Credit: Pete Beverly
The Charlotte Vermont House was able to achieve Net Zero Energy use by using the natural
resources of the site—the sun, the earth, and the wind.

The design of this Net Zero source energy Habitat for Humanity home carefully combines
envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar
features, including photovoltaics (PV), to reach the zero energy goal. The home uses the
utility power grid for storage—delivering energy to the grid when the PV system produces
more energy than the home uses and draws from the grid when the PV system produces less
energy than the house needs. This approach eliminates the need for battery storage and
reduces the cost, complexity, and maintenance of the solar electric system. Regular
discussions with Habitat construction staff and volunteers weighed the applicability of the
optimized solutions to the special needs and economics of a Habitat house which moved the
design toward simple, easily maintained mechanical systems, and volunteer-friendly
construction techniques. A data acquisition system was installed in the completed home to
monitor its performance.

This single family residence in Charlotte, Vermont was designed to maintain all the amenities
of a conventional home with as little environmental impact as possible; to eliminate all fossil
fuel burning on site; to maintain a high level of design and detail; and to use the most
conventional means and methods possible so that it would be affordable and replicable. The
challenge was to do all of this in a cold northern climate. The only way to achieve Net Zero
site and emissions energy use was to create a house which had an ultra low energy budget
utilizing all the natural renewable energy sources the site had to offer.
https://www.wbdg.org/resources/net-zero-energy-buildings