Professional Documents
Culture Documents
Brochure Commercial Escalators 2015 PDF
Brochure Commercial Escalators 2015 PDF
3
Basic data
21
10
11
13
18
14
12
3
17
5 16
2
4
6
20
19
9
15
23
4
Escalator components
8
7
22 1 Handrail 13 Step chain
2 Skirting 14 Tracks
3 Steps 15 Floor plate
4 Decking 16 Newel
5 Balustrade 17 Deflector device
6 Horizontal steps 18 Upper landing
7 Machine 19 Lower landing
8 Controller 20 Comb plate
9 Entry box 21 Main drive
10 Handrail drive 22 Junction box
11 Truss 23 Tension carriage
12 Exterior cladding
INNOVATIVE TECHNOLOGY
PROMOTES SAFETY FIRST
6
Standard safety devices
• Auxiliary brake – the upper landing. • Non reversal device • Floor plate safety device – device
This is a standard for vertical rise over (NRD, electronic) – in controller which is connected to floor plate and
6 m and is an option for rise below 6 m upper and lower landing, if floor plate
• Overspeed governor – covered by is not installed properly the escalator
• Emergency stop buttons – Located MESD control system cannot start
on the upper and lower horizontal sec-
tions and close to the skirt panel of the • Comb plate safety device – vertical • Warning signs – laber with pictograms,
handrail entry point. The safety stop can to prevent incorrect use of escalator
be manually activated by pressing the • Control device – stop buttons and key
red button in case of emergency switch can be activated when emer- • Missing step device – sensor device
gency issue or maintenance activity, this which monitors continuity of steps, to
• Handrail entry device – device which device can stop equipment immediately prevent hazard for passengers thanks to
keeps handrail tensioned, handrail with and protect passengers from any further missing step, possible serious accident
move after lead handrail tight and stay accident or injury
out to his rupture or on the contrary to • Handrail speed monitoring device –
his embossment • Deflector device – keeps a distance device which monitors speed between
between movable steps and skirt panel, step speed and handrail speed, this
• Broken step chain device – the safety protects passengers (especially children) safety device monitors proper handrail
switch is located on the tension car- from putting legs or fingers between running conditions. If the handrail loses
riage in the lower landing. If the step steps and skirt panel its tension or the handrail speed deviates
chain breaks or stretches abnormally, more than -15 % actual speed for more
the safety switch will initiate stopping the • Barrier panels – acrylic glass panels, than 15 s, the escalator will be stopped
escalator protect passengers from climbing on
lower deck at both landings or between • Control contact for brake lifting –
• Broken step and chain wheel adjacent escalators the device is used to detect the operation
control contact – This contact is of break lever (lift or fasten), to detect the
located at both landings. It will be • Wedge guards – acrylic glass deflector, operation of break lever (lift or fasten); once
activated if either a step or chain wheel which protect passengers from putting it falls to operate normally, the escalator will
is broken or a step is lowered due to their hands between two units in criss- stop immediately
rupture cross arrangement
2
3
6
5
1
8
8
OTIS safety devices
1 Comb plate safety device – Hand wheel – supported Entry steps for maintenance
horizontal – safety switch located device at machine, device room – metallic steps, to pre-
between comb plate and truss, if an which helps mechanic in case vent mechanics to step outside
object is drawn between the step of by a hand wheel of reinforced area
and the combs, it will lift the comb
plate to activate the safety contact. Motor cover control – switch Manual inspection control
After removing the object, the comb which controls covering of all device – inspection box to fa-
plates can be held down by adjustable moveable parts on motor, in cilitate service, adjustment and
springs. case covering is damaged switch repair, consists of one portable
is activated to stop operation button box and two sockets,
Controller lifting device for of escalator and reduce safety control escalator by pressing up
controller – device which helps hazard for mechanics and or down buttons as well as start
to plug out controller from upper passengers buttons
landing truss section, this device
helps mechanics to easily lifted out Escalator safety tool – tool Maintenance safety
controller from truss and reduce delivered with escalator, helps barrier – plastic barriers,
safety hazard and service time mechanics to set up escalator to prevent accessibility into
and to monitor further error escalator area through service
messages activities
2 Main drive chain speed sensor 7 LED Skirt panel lighting – can be Upthrust track device – sensor
incorporated to offer a further safety device which monitors step upthrust,
3 Control contact for brake lining alert for passengers and an impact- to prevent possible breaking of step
wear in machine resistant diffuser fully protects the and further hazard for passengers
light source
4 Auxiliary main drive brake Step chain roller monitoring
(wedge type) <= 6 m rise 8 Buzzer – acoustic device, voice device – safety devices at each side
signalization of emergency status at of the tension carriage, if the step
5 LED Under step lighting escalator chain breaks or stretches, tension
carriage will recoil and activate the
6 LED Comb lighting – alerts pas- Handrail broken device – device to safety contacts and stop operation of
sengers to the change from the monitor tension of handrail, to prevent escalator
moving step to fixed comb plate – and possible breaking of handrail and
vice versa. The area where the step further hazard for passengers Fire shutter operation – fire alarm
meshes into the comb plate can also signal provided by customer
be highlighted by a yellow strip. Skirt panel safety device – switch
installed between skirt panel and step Sprinkler system – pipes and
side, if an object is trapped between outlets on escalator connected into
the side of a step and the skirt panel, building fire system, to reduce or
the safety switch will be activated eliminate fire in building area
ENERGY-EFFICIENT, ECO-FRIENDLY
Special brush design provides full contact with the chain surface and minimal-
izes the oil dissipation which in turn ensures cleaner truss interior, essential
when considering transparent escalator cladding. Independent, programmable
controlling unit capable of interfacing with external devices and a single case
of oil reservoir warrant operating foreknowledge and surprisingly short mainte-
nance time. This extremely effective system contributes to lowering oil con-
sumption, saving up to 70 % more oil in comparison to the traditional lubrica-
tion system. Sealed-for-life bearings combined with high efficiency lubrication
systems minimize environmental impact.
10
Energy-saving modes
During operation, escalator has to handle the continuous changing load. Usually, short
periods of full load are followed by long periods of low load. So, constant standard mo-
tor power will result in unnecessary energy consumption.
As it becomes more important to reduce energy consumption nowadays, Otis has
developed three energy saving modes, including intermittent operation and Stand-By
variable frequency (VF) operation.
The VF drive runs at a reduced speed until a passenger approaches the escalator.
It then accelerates to a normal speed of 0,5 m/sec.
1 INTERMITTENT OPERATION
Suitable for an office building, people go to office in the morning and back
home in the evening.
Save up to 50 % energy
Escalator is resting with no passenger load.
Machine restarts by passenger detector (Piezo contact mat, photo cell barrier or radar)
Follow up movement when the last passenger left can be adjusted (10~255 sec)
Speed
10~255 sec delay (*)
Vnominal
0 Time
mode Δ mode
*Customer input parameter
2 ETA-PLUS
Suitable for an low traffic subway station located in suburb, people keep
coming and going in every minute during all day but without rush hour.
Save up to 30 % energy
Escalator runs continuously without no impact on the traffic flow. Improves efficiency of
the electric motor by switching to STAR mode when there are < 5 passengers on the
escalator.
Machine is controlled either in STAR or DELTA mode by means of passenger counter
device (contact mat or photo cell barrier).
Efficiency η of motor in optimum mode
empty escalator in STAR ηmotor ~ 0,85
empty escalator in DELTA ηmotor ~ 0,73
Speed
Vnominal
0 Time
mode Δ mode
*Customer input parameter
Stand-by VF
Speed
Full load VF
Speed
12
Outdoor packages
For installation of escalators under various weather conditions, Otis has defined differ-
ent packages, which includes:
OUTDOOR PACKAGE A2
Lighting economies
Skirt panel lighting has proved an increasingly attractive option to customers and
again achieves energy savings since we have replaced conventional spots with an LED
source.
Planning Shipping
First we dedicate a team of specialists to the project. • One piece shipment (standard product)
The team analyzes your expectations and helps to define a specification, taking into • Two piece shipment
account every conceivable merit from traffic to your aesthetic aspirations. Traffic flow • Three piece shipment
in a store, for instance, might be required to route passengers through a certain area. • Four piece shipment
The team will also provide advice to help you determine the most efficient arrangement
for installation – be that standard parallel, crisscross or scissor – and will also consider Once installed, a rigorous maintenance
vertical and horizontal distances to determine the escalator pitch and length. system is immediately put into place.
Otis maintenance contracts are recog-
Critical, too, is the physical installation itself. At Otis, we can either deliver the unit as a nized as industry’s benchmarks and
single piece or in a number of sections – depending on the cost and site considerations form a part of comprehensive strategic
and unit dimensions. approach designed to keep your
escalator running efficiently. An approach,
we believe, on which a long term
partnership is ultimately based.
14
Technical layout
DBE +40
SECTION
E 1.732 H G D-D
BA
min. = 3998 + 1.732 P K BH
D BF
BS PIT ARRANGEMENT
B
GH
RA
GH
FLOOR LINE
P
84
# 997
TO STEP NOSE LINE
W.P.
ARRANGEMENT
2
OF FLOOR OR
min.2300
CEILING OPENING
#9
D 40
80
max 2191
BT
BG
H
374 1000
3
U 341 930
374 1000
2
SEE DETAIL C 341 930
ALPH
A RA
RA GH FLAT STEPS
A
W.P.
230 +30
0
300
125
125
200 200
40 +20
0
400
500
Arrangements
16
Steps
Demarcation lines on one side Demarcation lines on two sides Demarcation lines on three sides
Decking
Aluminium powder coated silver Aluminium anodized silver grey FO10 Aluminium anodized gold FO7
gray
Sheet steel powder coated black Sheet steel powder coated silver grey Aluminium anodized silver grey FO10 Aluminium anodized gold F07
Otis
YourElevator
escalator
Company
factory 17
Design
Handrail
Cladding arrangement
Stainless steel G9 Stainless steel G2 Hairline finish Glass – clear Glass – RAL 9010 painted
extra clear glass
18
Balustrade glass panel colour
Skirt panel
Stainless steel hairline finish G2 Sheet steel low friction powder coated black RAL 9005
LED lighting
Blue
Green
COMB LIGHTING
BALUSTRADE ILLUMINATION
EXTENDED BALUSTRADE
max
1200 mm
20
... by OTIS
IN BOTTOM CLADDING
Spot lighting – one line Spot lighting – two lines Spot lighting – criss cross Two lines strip
Nákupní centrum Chodov, Prague, Czech Republic, 61 units Quadrio, Prague, Czech Republic, 6 units
22
Otis moves world
Vaňkovka Gallery, Brno, Czech Republic, 18 units Sazka arena, Prague, Czech Republic, 12 units
Otis reserves the right to change any part of this specification without prior notice.
The product colors in this brochure are representative not exact.
All rights reserved.