Professional Documents
Culture Documents
Water Spray Nozzle: Fire Fighting Equipment Data Sheet
Water Spray Nozzle: Fire Fighting Equipment Data Sheet
Water Spray Nozzle: Fire Fighting Equipment Data Sheet
ISSUE : SHEET OF
01 CUSTOMER: ITEM NO. :
02 PROJECT : QUANTITY :
03 LOCATION : SERVICE : FIRE WATER SYSTEM
04
05 CODE & STANDARDS
06 MODEL NO. A&B
07 APPROVALS J UL LISTED F FM APPROVED F KFEIC □ OTHERS
08 CODE & STANDARDS J NFPA □ BS J KFPL □ OTHERS
09 OPERATING CONDITIONS
10 TEMPERATURE MIN. : ( )℃ OPER. : ( AMB ) ℃ DESIGN : ( 60 )℃
11 PRESSURE MAXIMUM WORKING : ( 12.3 ) kg/cm² MIN. EFFECTIVE WORKING : ( 1.4 ~ 7 ) kg/cm²
12 FLUID HANDLED J WATER AND / OR F SEA WATER F FOAM-WATER SOLUTION
13 INSTALLATION J OUTDOOR AND / OR J INDOOR
14 DESIGN FEATURES
15 TYPE F HIGH VELOCITY J MEDIUM VELOCITY
16 SIZE & CONNECTION F 1/2" NPT MALE F 1/2" BSPT MALE
17 ORIFICE SIZE AND F 6.0 mm / K 22 F 7.0 mm / K 30 F 7.5 mm / K 35
18 K-FACTOR F 8.0 mm / K 41 F 9.0 mm / K 51 F 10.0mm / K 64
19 F 11.0mm / K 79 F 12.0mm / K 91 F 12.5mm / K 102
20 MATERIALS
21 HOUSING F BRASS / MODEL A F STAINLESS STEEL / MODEL B
22 DEFLECTOR PIN F BRASS / MODEL A F STAINLESS STEEL / MODEL B
23 DEFLECTOR F BRASS / MODEL A F STAINLESS STEEL / MODEL B
24 ACCESSORIES
25
26
27 TEST & INSPECTION
28 DIMENSION INSPECTION J WITNESS F REVIEW MATERIAL INSPECTION F WITNESS J REVIEW
29 VISUAL INSPECTION J WITNESS F REVIEW PERFORMANCE TEST F YES J NO
30 FINISH UNIT WEIGHT
31 PAINTING N/A ( 0.115 ) Kg
32 COLOR F NATURAL F CHROME PLATED
33
34
35
36
37
38
39
40
41
42
43
44 REV DATE PRP'D CHK'D APP'D DESCRIPTION
45 0 2006-11-25 J. K. JEONG Y. K. AN S. M. LEE FOR STANDARDIZATION
46 1
47 2
48 3
49 4
MEDIUM VELOCITY
WATER SPRAY NOZZLE
TECHNICAL DATA :
MODEL A & B
APPROVALS UL Listed for Model A Nozzle which is visibly damaged should not be installed.
ORDERING Specify K-Factor, spray angle Use Teflon tape or soft thread sealant on male thread
INFORMATION and finish. of the nozzle. The nozzles must be hand tightened into
the fitting. HD make wrench must be used to tighten
the nozzle unit into the fitting. Excessive tightening
APPLICATION torque may result into serious damage to nozzle arms
Medium velocity water spray nozzle has an external and the deflector which may affect spray pattern of
deflector, which discharges water in a directional cone the nozzle and it's performance.
shaped pattern of small droplet size. The water is
uniformly distributed over the surface to be protected. It is recommended that water spray system be
inspected regularly by authorised technical personnel.
The nozzle is used in deluge water spray system for The nozzle must be checked for corrosion, external and
special hazard fire protection application. internal obstruction, blockage if any. The nozzle should
be cleaned or replaced if required. The system must be
As the design and intent of specific water spray system operated with optimum water flow at least twice in a
may vary considerably, a MV nozzle is made available in year or as per the provisions of NFPA/TAC or local
several combination of orifice sizes and spray angles. authority having jurisdiction.
The minimum desirable pressure to achieve a reasonable The owner is solely responsible for maintaining the water
spray pattern is 1.4 Kg./Sq.cm. The water distribution spray system and the components therein so that it
pattern as shown in the graph in following pages is at performs properly when required.
an average pressure of 2.0 Kg/Sq.cm. The change in
pressure between 1.4 to 3.5 Kg./sq.cm. does not affect
DISCHARGE CHARACTERISTICS