Download as pdf or txt
Download as pdf or txt
You are on page 1of 96

Project Job Ref.

N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 1
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PILE CAP ANALYSIS & DESIGN (ACI318-11)


In accordance with ACI318-11
Tedds calculation version 2.0.00

Pile analysis summary


Unit Applied Allowable Utilization Result
Pile axial compression, pile 2 kN 289 663 0.436 PASS
Pile axial tension, pile 3 kN 170 367 0.463 PASS
Pile cap design summary
Unit Required Provided Utilization Result
Flexural reinforcement mm2 1620 (min) 3402 0.476 PASS
One way modified shear kN 413 1895 0.218 PASS
Two way col. mod. shear MPa 0.653 3.010 0.217 PASS
Two way pile shear MPa 0.856 1.310 0.654 PASS
One way corner pile shear kN 397 433 0.917 PASS

4
3
1800 mm

1 2

1800 mm

;
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 2
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

102 mm
500 mm

;
Pile cap details
Pile cap width, along x axis; Lx = 1800 mm
Pile cap width, along y axis; Ly = 1800 mm
Total cap depth; Dcap = 500 mm
Density of concrete; conc = 24 kN/m3
Height of soil above pile cap; hsoil = 0 mm
Density of soil above pile cap; soil = 17 kN/m3

Column details
Column width, along x axis; lx,col = 800 mm
Column width, along y axis; ly,col = 800 mm
Column location, x axis; xc = 900 mm
Column location, y axis; yc = 900 mm
Pile details
Pile material; Concrete
Concrete pile section; Circular
Pile diameter; hpile = 300 mm
Allowable axial compression load; PpC,allow = 662.9 kN
Allowable axial tension load; PpT,allow = 366.7 kN
Allowable lateral load; Vp,allow = 92.9 kN
Number of piles; Np = 4.000
Pile embedment; dembed = 102 mm
Pile number x location (mm) y location (mm)
1 532 506
2 1415 481
3 396 1247
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 3
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

4 1334 1361

Column axial loads


Axial dead load; PD = 210.6 kN
Total area axial dead load; PD,area = conc  Lx  Ly  Dcap = 38.9 kN
Axial rooflive load; PLr = 145.1 kN
Axial wind load; PW = 72.6 kN
Axial seismic load; PE = 11.7 kN
Column shear loads
Shear dead load, along x axis; VxD = 0.8 kN
Shear rooflive load, along x axis; VxLr = 0.6 kN
Shear wind load, along x axis; VxW = 12.2 kN
Shear seismic load, along x axis; VxE = 32.8 kN
Shear dead load, along y axis; VyD = 3.4 kN
Shear rooflive load, along y axis; VyLr = 3.5 kN
Shear wind load, along y axis; VyW = 15.4 kN
Shear seismic load, along y axis; VyE = 36.9 kN
Column moment loads
Moment dead load, about x-x axis; MxD = 12.9 kNm
Moment rooflive load, about x-x axis; MxLr = 13.4 kNm
Moment wind load, about x-x axis; MxW = 106.0 kNm
Moment seismic load, about x-x axis; MxE = 253.7 kNm
Moment dead load, about y-y axis; MyD = 3.9 kNm
Moment rooflive load, about y-y axis; MyLr = 2.8 kNm
Moment wind load, about y-y axis; MyW = 77.1 kNm
Moment seismic load, about y-y axis; MyE = 246.4 kNm
Pile group centroid
Centroid location, x direction; xpg,c = (xp1 + xp2 + xp3 + xp4) / Np = 919 mm
Centroid location, y direction; ypg,c = (yp1 + yp2 + yp3 + yp4) / Np = 899 mm
Pile distance from centroid
Pile 1 centroid distance, x direction; xp1,c = xp1 - xpg,c = -387 mm
Pile 1 centroid distance, y direction; yp1,c = yp1 - ypg,c = -393 mm
Pile 2 centroid distance, x direction; xp2,c = xp2 - xpg,c = 496 mm
Pile 2 centroid distance, y direction; yp2,c = yp2 - ypg,c = -417 mm
Pile 3 centroid distance, x direction; xp3,c = xp3 - xpg,c = -523 mm
Pile 3 centroid distance, y direction; yp3,c = yp3 - ypg,c = 348 mm
Pile 4 centroid distance, x direction; xp4,c = xp4 - xpg,c = 415 mm
Pile 4 centroid distance, y direction; yp4,c = yp4 - ypg,c = 462 mm
Moment of inertia of pile group
Moment of inertia about x-x axis; Ixx = yp1,c2 + yp2,c2 + yp3,c2 + yp4,c2 = 663127 mm2
Moment of inertia about y-y axis; Iyy = xp1,c2 + xp2,c2 + xp3,c2 + xp4,c2 = 841385 mm2
Loading eccentricity
Eccentricity of column load, x direction; ex,c = xc - xpg,c = -19 mm
Eccentricity of column load, y direction; ey,c = yc - ypg,c = 1 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 4
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Dead load pile forces


Dead load moment about x-x axis; MxD,Des = MxD + (-1)  PD  ey,c + (-1)  VyD  Dcap = 10.9 kNm
Dead load moment about y-y axis; MyD,Des = MyD + PD  ex,c + VxD  Dcap = 0.3 kNm
Dead axial load on pile 1; Pp1,D = (PD + PD,area) / Np + MyD,Des  xp1,c / Iyy + MxD,Des  (-1)  yp1,c / Ixx = 69
kN
Dead axial load on pile 2; Pp2,D = (PD + PD,area) / Np + MyD,Des  xp2,c / Iyy + MxD,Des  (-1)  yp2,c / Ixx = 69
kN
Dead axial load on pile 3; Pp3,D = (PD + PD,area) / Np + MyD,Des  xp3,c / Iyy + MxD,Des  (-1)  yp3,c / Ixx = 56
kN
Dead axial load on pile 4; Pp4,D = (PD + PD,area) / Np + MyD,Des  xp4,c / Iyy + MxD,Des  (-1)  yp4,c / Ixx = 55
kN

RoofLive load pile forces


RoofLive load moment about x-x axis; MxLr,Des = MxLr + (-1)  PLr  ey,c + (-1)  VyLr  Dcap = 11.5 kNm
RoofLive load moment about y-y axis; MyLr,Des = MyLr + PLr  ex,c + VxLr  Dcap = 0.3 kNm
RoofLive axial load on pile 1; Pp1,Lr = PLr / Np + MyLr,Des  xp1,c / Iyy + MxLr,Des  (-1)  yp1,c / Ixx = 43 kN
RoofLive axial load on pile 2; Pp2,Lr = PLr / Np + MyLr,Des  xp2,c / Iyy + MxLr,Des  (-1)  yp2,c / Ixx = 44 kN
RoofLive axial load on pile 3; Pp3,Lr = PLr / Np + MyLr,Des  xp3,c / Iyy + MxLr,Des  (-1)  yp3,c / Ixx = 30 kN
RoofLive axial load on pile 4; Pp4,Lr = PLr / Np + MyLr,Des  xp4,c / Iyy + MxLr,Des  (-1)  yp4,c / Ixx = 28 kN

Wind load pile forces


Wind load moment about x-x axis; MxW,Des = MxW + (-1)  PW  ey,c + (-1)  VyW  Dcap = 98.2 kNm
Wind load moment about y-y axis; MyW,Des = MyW + PW  ex,c + VxW  Dcap = 81.8 kNm
Wind axial load on pile 1; Pp1,W = PW / Np + MyW,Des  xp1,c / Iyy + MxW,Des  (-1)  yp1,c / Ixx = 39 kN
Wind axial load on pile 2; Pp2,W = PW / Np + MyW,Des  xp2,c / Iyy + MxW,Des  (-1)  yp2,c / Ixx = 128 kN
Wind axial load on pile 3; Pp3,W = PW / Np + MyW,Des  xp3,c / Iyy + MxW,Des  (-1)  yp3,c / Ixx = -84 kN
Wind axial load on pile 4; Pp4,W = PW / Np + MyW,Des  xp4,c / Iyy + MxW,Des  (-1)  yp4,c / Ixx = -10 kN

Seismic load pile forces


Seismic load moment about x-x axis; MxE,Des = MxE + (-1)  PE  ey,c + (-1)  VyE  Dcap = 235.2 kNm
Seismic load moment about y-y axis; MyE,Des = MyE + PE  ex,c + VxE  Dcap = 262.5 kNm
Seismic axial load on pile 1; Pp1,E = PE / Np + MyE,Des  xp1,c / Iyy + MxE,Des  (-1)  yp1,c / Ixx = 21 kN
Seismic axial load on pile 2; Pp2,E = PE / Np + MyE,Des  xp2,c / Iyy + MxE,Des  (-1)  yp2,c / Ixx = 306 kN
Seismic axial load on pile 3; Pp3,E = PE / Np + MyE,Des  xp3,c / Iyy + MxE,Des  (-1)  yp3,c / Ixx = -284 kN
Seismic axial load on pile 4; Pp4,E = PE / Np + MyE,Des  xp4,c / Iyy + MxE,Des  (-1)  yp4,c / Ixx = -31 kN

ASCE 7-10 load combinations (ASD)


1.0D (0.105)
1.0D + 1.0L (0.105)
1.0D + 1.0Lr (0.171)
1.0D + 1.0S (0.105)
1.0D + 1.0R (0.105)
1.0D + 0.75L + 0.75Lr (0.154)
1.0D + 0.75L + 0.75S (0.105)
1.0D + 0.75L + 0.75R (0.105)
1.0D + 0.6W (0.221)
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 5
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

(1.0 + 0.14SDS)D + 0.7E (0.436)


1.0D + 0.75L + 0.75Lr + 0.45W (0.241)
1.0D + 0.75L + 0.75S + 0.45W (0.192)
1.0D + 0.75L + 0.75R + 0.45W (0.192)
(1.0 + 0.10SDS)D + 0.75L + 0.75S + 0.525E (0.353)
0.6D + 0.6W (0.179)
(0.6 - 0.14SDS)D + 0.7E (0.463)

Combination 1 results: 1.0D


Pile 1 axial load; Pp1 = 1.0  Pp1,D = 68.7 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D = 69.4 kN
max(Pp2 / PpC,allow,0) = 0.105
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D = 56.5 kN
max(Pp3 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D = 54.9 kN
max(Pp4 / PpC,allow,0) = 0.083
PASS - Pile allowable compression load exceeds axial force
Combination 2 results: 1.0D + 1.0L
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,L = 68.7 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,L = 69.4 kN
max(Pp2 / PpC,allow,0) = 0.105
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,L = 56.5 kN
max(Pp3 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,L = 54.9 kN
max(Pp4 / PpC,allow,0) = 0.083
PASS - Pile allowable compression load exceeds axial force
Combination 3 results: 1.0D + 1.0Lr
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,Lr = 111.7 kN
max(Pp1 / PpC,allow,0) = 0.168
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,Lr = 113.1 kN
max(Pp2 / PpC,allow,0) = 0.171
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,Lr = 86.5 kN
max(Pp3 / PpC,allow,0) = 0.130
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,Lr = 83.3 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 6
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

max(Pp4 / PpC,allow,0) = 0.126


PASS - Pile allowable compression load exceeds axial force
Combination 4 results: 1.0D + 1.0S
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,S = 68.7 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,S = 69.4 kN
max(Pp2 / PpC,allow,0) = 0.105
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,S = 56.5 kN
max(Pp3 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,S = 54.9 kN
max(Pp4 / PpC,allow,0) = 0.083
PASS - Pile allowable compression load exceeds axial force
Combination 5 results: 1.0D + 1.0R
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,R = 68.7 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,R = 69.4 kN
max(Pp2 / PpC,allow,0) = 0.105
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,R = 56.5 kN
max(Pp3 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,R = 54.9 kN
max(Pp4 / PpC,allow,0) = 0.083
PASS - Pile allowable compression load exceeds axial force
Combination 6 results: 1.0D + 0.75L + 0.75Lr
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,Lr = 100.9 kN
max(Pp1 / PpC,allow,0) = 0.152
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,Lr = 102.2 kN
max(Pp2 / PpC,allow,0) = 0.154
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,Lr = 79 kN
max(Pp3 / PpC,allow,0) = 0.119
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,Lr = 76.2 kN
max(Pp4 / PpC,allow,0) = 0.115
PASS - Pile allowable compression load exceeds axial force
Combination 7 results: 1.0D + 0.75L + 0.75S
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S = 68.7 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 7
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

max(Pp1 / PpC,allow,0) = 0.104


PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S = 69.4 kN
max(Pp2 / PpC,allow,0) = 0.105
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S = 56.5 kN
max(Pp3 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S = 54.9 kN
max(Pp4 / PpC,allow,0) = 0.083
PASS - Pile allowable compression load exceeds axial force
Combination 8 results: 1.0D + 0.75L + 0.75R
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,R = 68.7 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,R = 69.4 kN
max(Pp2 / PpC,allow,0) = 0.105
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,R = 56.5 kN
max(Pp3 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,R = 54.9 kN
max(Pp4 / PpC,allow,0) = 0.083
PASS - Pile allowable compression load exceeds axial force
Combination 9 results: 1.0D + 0.6W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.6  Pp1,W = 91.9 kN
max(Pp1 / PpC,allow,0) = 0.139
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.6  Pp2,W = 146.3 kN
max(Pp2 / PpC,allow,0) = 0.221
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.6  Pp3,W = 5.9 kN
max(Pp3 / PpC,allow,0) = 0.009
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.6  Pp4,W = 48.9 kN
max(Pp4 / PpC,allow,0) = 0.074
PASS - Pile allowable compression load exceeds axial force

Combination 10 results: (1.0 + 0.14SDS)D + 0.7E


Pile 1 axial load; Pp1 = 1.085  Pp1,D + 0.7  Pp1,E = 89.5 kN
max(Pp1 / PpC,allow,0) = 0.135
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.085  Pp2,D + 0.7  Pp2,E = 289.3 kN
max(Pp2 / PpC,allow,0) = 0.436
PASS - Pile allowable compression load exceeds axial force
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 8
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile 3 axial load; Pp3 = 1.085  Pp3,D + 0.7  Pp3,E = -137.4 kN


max(Pp3 / (-1  PpT,allow),0) = 0.375
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.085  Pp4,D + 0.7  Pp4,E = 37.6 kN
max(Pp4 / PpC,allow,0) = 0.057
PASS - Pile allowable compression load exceeds axial force
Combination 11 results: 1.0D + 0.75L + 0.75Lr + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,Lr + 0.45  Pp1,W = 118.3 kN
max(Pp1 / PpC,allow,0) = 0.178
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,Lr + 0.45  Pp2,W = 159.9 kN
max(Pp2 / PpC,allow,0) = 0.241
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,Lr + 0.45  Pp3,W = 41 kN
max(Pp3 / PpC,allow,0) = 0.062
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,Lr + 0.45  Pp4,W = 71.7 kN
max(Pp4 / PpC,allow,0) = 0.108
PASS - Pile allowable compression load exceeds axial force
Combination 12 results: 1.0D + 0.75L + 0.75S + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S + 0.45  Pp1,W = 86.1 kN
max(Pp1 / PpC,allow,0) = 0.130
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S + 0.45  Pp2,W = 127.1 kN
max(Pp2 / PpC,allow,0) = 0.192
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S + 0.45  Pp3,W = 18.5 kN
max(Pp3 / PpC,allow,0) = 0.028
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S + 0.45  Pp4,W = 50.4 kN
max(Pp4 / PpC,allow,0) = 0.076
PASS - Pile allowable compression load exceeds axial force
Combination 13 results: 1.0D + 0.75L + 0.75R + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,R + 0.45  Pp1,W = 86.1 kN
max(Pp1 / PpC,allow,0) = 0.130
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,R + 0.45  Pp2,W = 127.1 kN
max(Pp2 / PpC,allow,0) = 0.192
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,R + 0.45  Pp3,W = 18.5 kN
max(Pp3 / PpC,allow,0) = 0.028
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,R + 0.45  Pp4,W = 50.4 kN
max(Pp4 / PpC,allow,0) = 0.076
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 9
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Pile allowable compression load exceeds axial force

Combination 14 results: (1.0 + 0.10SDS)D + 0.75L + 0.75S + 0.525E


Pile 1 axial load; Pp1 = 1.06  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S + 0.525  Pp1,E = 84 kN
max(Pp1 / PpC,allow,0) = 0.127
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.06  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S + 0.525  Pp2,E = 234 kN
max(Pp2 / PpC,allow,0) = 0.353
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.06  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S + 0.525  Pp3,E = -89.2 kN
max(Pp3 / (-1  PpT,allow),0) = 0.243
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.06  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S + 0.525  Pp4,E = 41.7 kN
max(Pp4 / PpC,allow,0) = 0.063
PASS - Pile allowable compression load exceeds axial force
Combination 15 results: 0.6D + 0.6W
Pile 1 axial load; Pp1 = 0.6  Pp1,D + 0.6  Pp1,W = 64.4 kN
max(Pp1 / PpC,allow,0) = 0.097
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 0.6  Pp2,D + 0.6  Pp2,W = 118.6 kN
max(Pp2 / PpC,allow,0) = 0.179
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 0.6  Pp3,D + 0.6  Pp3,W = -16.7 kN
max(Pp3 / (-1  PpT,allow),0) = 0.046
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 0.6  Pp4,D + 0.6  Pp4,W = 27 kN
max(Pp4 / PpC,allow,0) = 0.041
PASS - Pile allowable compression load exceeds axial force

Combination 16 results: (0.6 - 0.14SDS)D + 0.7E


Pile 1 axial load; Pp1 = 0.515  Pp1,D + 0.7  Pp1,E = 50.3 kN
max(Pp1 / PpC,allow,0) = 0.076
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 0.515  Pp2,D + 0.7  Pp2,E = 249.7 kN
max(Pp2 / PpC,allow,0) = 0.377
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 0.515  Pp3,D + 0.7  Pp3,E = -169.6 kN
max(Pp3 / (-1  PpT,allow),0) = 0.463
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 0.515  Pp4,D + 0.7  Pp4,E = 6.3 kN
max(Pp4 / PpC,allow,0) = 0.009
PASS - Pile allowable compression load exceeds axial force
Pile cap design
Material details
Compressive strength of concrete; f'c = 28.000 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 10
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete type; Normal weight


Concrete modification factor; =1
Yield strength of reinforcement; fy = 420.000 MPa
Nominal cover to top reinforcement; cnom,top = 50 mm
Nominal cover to bottom reinforcement; cnom,bot = 50 mm
ASCE 7-10 load combinations (LRFD)
1.4D (0.476)
1.2D + 1.6L + 0.5Lr (0.476)
1.2D + 1.6L + 1  0.5S (0.476)
1.2D + 1.6L + 0.5R (0.476)
1.2D + 1.0L + 1.6Lr (0.476)
1.2D + 1.0L + 1.6S (0.476)
1.2D + 1.0L + 1.6R (0.476)
1.2D + 1.6Lr + 0.5W (0.501)
1.2D + 1.6S + 0.5W (0.476)
1.2D + 1.6R + 0.5W (0.476)
1.2D + 1.0L + 0.5Lr + 1.0W (0.538)
1.2D + 1.0L + 1  0.5S + 1.0W (0.488)
1.2D + 1.0L + 0.5R + 1.0W (0.488)
(1.2 + 0.2  SDS)D + 1.0L + 1  0.2S + 1.0E (0.917)
0.9D + 1.0W (0.476)
(0.9 - 0.2  SDS)D + 1.0E (0.830)

Combination 1 results: 1.4D


Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 23.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.057
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 11
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, positive moment


Ultimate bending moment; Mu = 13.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.034
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 128.5 kN
Ultimate moment force at face of column; Mu = 16.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.064
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 152.5 kN
Ultimate moment force at face of column; Mu = 23.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.076
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 12
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 108.5 kN
Ultimate moment force at face of column; Mu = 10.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.057
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 142.1 kN
Ultimate moment force at face of column; Mu = 13.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.075
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD1,Pp2,LRFD1,Pp3,LRFD1,Pp4,LRFD1) - 1.4  (conc 
Dcap)  (Acap - AInsidePerim)) = 321.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.387 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 13
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.129
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD1) = 96.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.186 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.142
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD1) = 97.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.209 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.160
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 14
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 3


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD1) = 79.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.161 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.123
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD1) = 76.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.161 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.123
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD1) = 96.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 15
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 485.6 kN


Vu / Vn = 0.198
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD1) = 97.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.224
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD1) = 79.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD1) = 76.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.173
PASS - Design shear capacity exceeds ultimate shear load
Combination 2 results: 1.2D + 1.6L + 0.5Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 25.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 16
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm


Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.062
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 15.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.039
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 139.5 kN
Ultimate moment force at face of column; Mu = 18.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.069
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 165.6 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 17
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 25.9 kNm


Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.082
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 116.1 kN
Ultimate moment force at face of column; Mu = 11.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.061
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 157.0 kN
Ultimate moment force at face of column; Mu = 15.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.083
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 18
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD2,Pp2,LRFD2,Pp3,LRFD2,Pp4,LRFD2) - 1.2  (conc 


Dcap)  (Acap - AInsidePerim)) = 347.9 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.419 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD2) = 103.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.200 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.153
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD2) = 105.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.227 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 19
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile location factor (11.11.2.1); s =20


Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.173
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD2) = 82.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.169 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.129
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD2) = 80.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.168 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 20
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa


vug / vn = 0.128
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD2) = 103.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.214
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD2) = 105.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.243
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD2) = 82.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.181
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD2) = 80.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.180
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 21
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Combination 3 results: 1.2D + 1.6L + 1  0.5S

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 20.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.049
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 11.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.029
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 110.1 kN
Ultimate moment force at face of column; Mu = 14.0 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 22
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm


Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.7 kN
Ultimate moment force at face of column; Mu = 20.1 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.065
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 93.0 kN
Ultimate moment force at face of column; Mu = 9.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.049
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 121.8 kN
Ultimate moment force at face of column; Mu = 11.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 23
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.064
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD3,Pp2,LRFD3,Pp3,LRFD3,Pp4,LRFD3) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 275.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.332 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD3) = 82.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.159 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 24
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vug / vn = 0.121


PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD3) = 83.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.180 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD3) = 67.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 25
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Pp4,LRFD3) = 65.9 kN


Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD3) = 82.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.170
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD3) = 83.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD3) = 67.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 26
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 4


Ultimate shear force; Vu = abs(Pp4,LRFD3) = 65.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
Combination 4 results: 1.2D + 1.6L + 0.5R
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 20.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.049
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 11.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 27
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134


PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.029
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 110.1 kN
Ultimate moment force at face of column; Mu = 14.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.7 kN
Ultimate moment force at face of column; Mu = 20.1 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.065
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 93.0 kN
Ultimate moment force at face of column; Mu = 9.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.049
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 28
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, bottom side


Ultimate shear force at face of column; Vu = 121.8 kN
Ultimate moment force at face of column; Mu = 11.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.064
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD4,Pp2,LRFD4,Pp3,LRFD4,Pp4,LRFD4) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 275.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.332 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD4) = 82.5 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 29
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.159 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.121
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD4) = 83.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.180 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD4) = 67.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 30
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD4) = 65.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD4) = 82.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.170
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD4) = 83.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 31
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 3


Ultimate shear force; Vu = abs(Pp3,LRFD4) = 67.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD4) = 65.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
Combination 5 results: 1.2D + 1.0L + 1.6Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 38.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.093
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 23.6 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 32
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)


Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.061
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 204.3 kN
Ultimate moment force at face of column; Mu = 26.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.102
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 242.3 kN
Ultimate moment force at face of column; Mu = 38.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.121
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 166.9 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 33
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 17.5 kNm


Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.088
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 234.5 kN
Ultimate moment force at face of column; Mu = 23.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD5,Pp2,LRFD5,Pp3,LRFD5,Pp4,LRFD5) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 506.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.610 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 34
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa


Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.203
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD5) = 151.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.291 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.223
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD5) = 153.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.330 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.252
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 35
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter width; ly,perim = 845 mm


Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD5) = 115.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.236 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.180
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD5) = 111.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.234 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.178
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD5) = 151.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.311
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 36
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 2


Ultimate shear force; Vu = abs(Pp2,LRFD5) = 153.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.353
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD5) = 115.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.253
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD5) = 111.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.250
PASS - Design shear capacity exceeds ultimate shear load
Combination 6 results: 1.2D + 1.0L + 1.6S
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 20.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 37
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278


PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.049
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 11.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.029
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 110.1 kN
Ultimate moment force at face of column; Mu = 14.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.7 kN
Ultimate moment force at face of column; Mu = 20.1 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 38
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.065
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 93.0 kN
Ultimate moment force at face of column; Mu = 9.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.049
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 121.8 kN
Ultimate moment force at face of column; Mu = 11.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.064
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD6,Pp2,LRFD6,Pp3,LRFD6,Pp4,LRFD6) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 275.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.332 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 39
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00


Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD6) = 82.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.159 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.121
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD6) = 83.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.180 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 40
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa


Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD6) = 67.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD6) = 65.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 41
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 1


Ultimate shear force; Vu = abs(Pp1,LRFD6) = 82.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.170
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD6) = 83.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD6) = 67.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD6) = 65.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
Combination 7 results: 1.2D + 1.0L + 1.6R
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 20.1 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 42
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)


Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.049
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 11.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.029
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 110.1 kN
Ultimate moment force at face of column; Mu = 14.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 43
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.7 kN
Ultimate moment force at face of column; Mu = 20.1 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.065
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 93.0 kN
Ultimate moment force at face of column; Mu = 9.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.049
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 121.8 kN
Ultimate moment force at face of column; Mu = 11.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.064
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 44
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column modified two way shear design


Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD7,Pp2,LRFD7,Pp3,LRFD7,Pp4,LRFD7) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 275.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.332 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD7) = 82.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.159 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.121
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 45
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 2


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD7) = 83.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.180 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD7) = 67.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD7) = 65.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.138 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 46
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.106
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD7) = 82.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.170
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD7) = 83.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD7) = 67.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD7) = 65.9 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 47
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
Combination 8 results: 1.2D + 1.6Lr + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 50.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.122
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 31.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 48
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.081
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 175.1 kN
Ultimate moment force at face of column; Mu = 20.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.087
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 301.9 kN
Ultimate moment force at face of column; Mu = 50.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.150
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 137.0 kN
Ultimate moment force at face of column; Mu = 14.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.072
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 304.4 kN
Ultimate moment force at face of column; Mu = 31.4 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 49
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm


Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.161
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD8,Pp2,LRFD8,Pp3,LRFD8,Pp4,LRFD8) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 542.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.653 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.217
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD8) = 170.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.329 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 50
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.251
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD8) = 217.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.468 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.358
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD8) = 73.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.150 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 51
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vug / vn = 0.115


PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD8) = 106.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.223 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.171
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD8) = 170.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.351
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD8) = 217.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.501
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD8) = 73.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 52
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.161
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD8) = 106.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.239
PASS - Design shear capacity exceeds ultimate shear load
Combination 9 results: 1.2D + 1.6S + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 31.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 19.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 53
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.049
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 80.9 kN
Ultimate moment force at face of column; Mu = 7.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.040
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 190.3 kN
Ultimate moment force at face of column; Mu = 31.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.095
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 63.1 kN
Ultimate moment force at face of column; Mu = 6.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 54
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.033
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 191.7 kN
Ultimate moment force at face of column; Mu = 19.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.101
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD9,Pp2,LRFD9,Pp3,LRFD9,Pp4,LRFD9) - 1.2  (conc 
Dcap)  (Acap - AInsidePerim)) = 311.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.375 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.125
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 55
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 1


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD9) = 101.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.196 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.150
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD9) = 147.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.318 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.243
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD9) = 25.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.052 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 56
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.040
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD9) = 60.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.128 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD9) = 101.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.210
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD9) = 147.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 57
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.340
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD9) = 25.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.056
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD9) = 60.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
Combination 10 results: 1.2D + 1.6R + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 31.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 58
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 19.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.049
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 80.9 kN
Ultimate moment force at face of column; Mu = 7.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.040
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 190.3 kN
Ultimate moment force at face of column; Mu = 31.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 59
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.095
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 63.1 kN
Ultimate moment force at face of column; Mu = 6.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.033
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 191.7 kN
Ultimate moment force at face of column; Mu = 19.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.101
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD10,Pp2,LRFD10,Pp3,LRFD10,Pp4,LRFD10) - 1.2  (conc
 Dcap)  (Acap - AInsidePerim)) = 311.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.375 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 60
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column location factor (11.11.2.1); s =20


Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.125
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD10) = 101.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.196 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.150
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD10) = 147.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.318 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 61
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.243
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD10) = 25.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.052 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.040
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD10) = 60.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.128 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD10) = 101.8 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 62
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.210
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD10) = 147.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.340
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD10) = 25.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.056
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD10) = 60.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
Combination 11 results: 1.2D + 1.0L + 0.5Lr + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 49.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 63
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2


PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.119
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 30.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.079
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 81.1 kN
Ultimate moment force at face of column; Mu = 5.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 64
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 2007.8 kN


Vu / Vn = 0.040
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 284.7 kN
Ultimate moment force at face of column; Mu = 49.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.142
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 56.3 kN
Ultimate moment force at face of column; Mu = 6.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.030
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 296.8 kN
Ultimate moment force at face of column; Mu = 30.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 65
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter length; lx,perim = 1300 mm


Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD11,Pp2,LRFD11,Pp3,LRFD11,Pp4,LRFD11) - 1.2  (conc
 Dcap)  (Acap - AInsidePerim)) = 419.8 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.505 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.168
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD11) = 142.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.275 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.210
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 66
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm


Ultimate shear load; Vu = abs(Pp2,LRFD11) = 233.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.503 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.384
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD11) = 1.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.003 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.002
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD11) = 70.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 67
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa


vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD11) = 142.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.294
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD11) = 233.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.538
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD11) = 1.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.003
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD11) = 70.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 68
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.158
PASS - Design shear capacity exceeds ultimate shear load

Combination 12 results: 1.2D + 1.0L + 1  0.5S + 1.0W

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 43.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.105
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 27.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.069
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 69
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design moment capacity exceeds ultimate moment load


One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 51.7 kN
Ultimate moment force at face of column; Mu = 1.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.026
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 249.8 kN
Ultimate moment force at face of column; Mu = 43.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 33.2 kN
Ultimate moment force at face of column; Mu = 3.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.018
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 261.6 kN
Ultimate moment force at face of column; Mu = 27.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 70
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.138
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD12,Pp2,LRFD12,Pp3,LRFD12,Pp4,LRFD12) - 1.2  (conc
 Dcap)  (Acap - AInsidePerim)) = 347.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.418 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD12) = 121.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.234 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 71
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa


Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.178
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD12) = 211.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.456 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.348
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD12) = 16.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.034 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.026
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 72
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 4


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD12) = 56.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.117 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.090
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD12) = 121.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.249
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD12) = 211.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.488
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD12) = 16.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 73
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.036
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD12) = 56.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.126
PASS - Design shear capacity exceeds ultimate shear load
Combination 13 results: 1.2D + 1.0L + 0.5R + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 43.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.105
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 27.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 74
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm


Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.069
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 51.7 kN
Ultimate moment force at face of column; Mu = 1.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.026
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 249.8 kN
Ultimate moment force at face of column; Mu = 43.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 33.2 kN
Ultimate moment force at face of column; Mu = 3.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 75
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.018
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 261.6 kN
Ultimate moment force at face of column; Mu = 27.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.138
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2  (conc
 Dcap)  (Acap - AInsidePerim)) = 347.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.418 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 76
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 1


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD13) = 121.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.234 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.178
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD13) = 211.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.456 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.348
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD13) = 16.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.034 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 77
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.026
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD13) = 56.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.117 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.090
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD13) = 121.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.249
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD13) = 211.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 78
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.488
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD13) = 16.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.036
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD13) = 56.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.126
PASS - Design shear capacity exceeds ultimate shear load

Combination 14 results: (1.2 + 0.2  SDS)D + 1.0L + 1  0.2S + 1.0E

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 77.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 79
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.186
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 44.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.113
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 34.7 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.064
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 80
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, negative moment


Ultimate bending moment; Mu = 7.7 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top - y.top / 2 = 422 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02911
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 578.5 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 520.6 kNm
Mu / Mn = 0.015
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 148.3 kN
Ultimate moment force at face of column; Mu = 34.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1812.0 kN
Design shear capacity; Vn = v  Vn = 1359.0 kN
Vu / Vn = 0.109
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 420.7 kN
Ultimate moment force at face of column; Mu = 77.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.210
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 81
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 97.0 kN
Ultimate moment force at face of column; Mu = 7.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.051
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 413.1 kN
Ultimate moment force at face of column; Mu = 44.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.218
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD14,Pp2,LRFD14,Pp3,LRFD14,Pp4,LRFD14) - 1.321 
(conc  Dcap)  (Acap - AInsidePerim)) = 314.8 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.379 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 82
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.126
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD14) = 112.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.216 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.165
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD14) = 397.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.856 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.654
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 83
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 3


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD14) = 209.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.427 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.326
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD14) = 41.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.086 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.066
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD14) = 112.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 84
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 485.6 kN


Vu / Vn = 0.231
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD14) = 397.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.917
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD14) = 209.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.457
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD14) = 41.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.092
PASS - Design shear capacity exceeds ultimate shear load
Combination 15 results: 0.9D + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 38.5 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 85
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm


Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.093
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 24.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.062
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 2.5 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 86
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm


Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.005
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 24.2 kN
Ultimate moment force at face of column; Mu = 2.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.012
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 217.1 kN
Ultimate moment force at face of column; Mu = 38.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.108
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 9.9 kN
Ultimate moment force at face of column; Mu = 1.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.005
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 231.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 87
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 24.1 kNm


Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.122
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD15,Pp2,LRFD15,Pp3,LRFD15,Pp4,LRFD15) - 0.9  (conc
 Dcap)  (Acap - AInsidePerim)) = 278.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.335 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.111
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm
Ultimate shear load; Vu = abs(Pp1,LRFD15) = 100.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.194 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 88
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile location factor (11.11.2.1); s =20


Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.148
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD15) = 190.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.411 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.314
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD15) = 33.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.068 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 89
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa


vug / vn = 0.052
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD15) = 39.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.083 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.063
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD15) = 100.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.207
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD15) = 190.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Vu / Vn = 0.440
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD15) = 33.5 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 90
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.073
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD15) = 39.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.089
PASS - Design shear capacity exceeds ultimate shear load

Combination 16 results: (0.9 - 0.2  SDS)D + 1.0E

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 68.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.165
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 39.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 91
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Area of reinforcement provided exceeds minimum


Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.100
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 41.0 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.075
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, negative moment
Ultimate bending moment; Mu = 11.7 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top - y.top / 2 = 422 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 92
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Neutral axis factor; 1 = 0.85


Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02911
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 578.5 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 520.6 kNm
Mu / Mn = 0.022
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 198.1 kN
Ultimate moment force at face of column; Mu = 41.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 104 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2034.5 kN
Design shear capacity; Vn = v  Vn = 1525.9 kN
Vu / Vn = 0.130
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 361.7 kN
Ultimate moment force at face of column; Mu = 68.1 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 34 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.180
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 139.0 kN
Ultimate moment force at face of column; Mu = 11.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 61 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 93
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.073
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 358.1 kN
Ultimate moment force at face of column; Mu = 39.1 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 19 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.189
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 34 mm
Distance to closest pile, y direction; wy = 19 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(0.983  Pp1,LRFD16,Pp2,LRFD16,Pp3,LRFD16,Pp4,LRFD16) - 0.779 
(conc  Dcap)  (Acap - AInsidePerim)) = 190.3 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.229 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 4.391 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 4.014 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 3.010 MPa
vumod / vn = 0.076
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 824 mm
Shear perimeter width; ly,perim = 799 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 94
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1623 mm


Ultimate shear load; Vu = abs(Pp1,LRFD16) = 74.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.144 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.607 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 678 mm
Shear perimeter width; ly,perim = 774 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1452 mm
Ultimate shear load; Vu = abs(Pp2,LRFD16) = 359.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.775 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.811 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.592
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 689 mm
Shear perimeter width; ly,perim = 845 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1534 mm
Ultimate shear load; Vu = abs(Pp3,LRFD16) = 239.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.489 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.708 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 95
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa


vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.374
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 759 mm
Shear perimeter width; ly,perim = 732 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1491 mm
Ultimate shear load; Vu = abs(Pp4,LRFD16) = 11.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.024 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.761 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.018
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD16) = 74.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2253 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 647.4 kN
Design shear capacity; Vn = v  Vn = 485.6 kN
Vu / Vn = 0.154
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD16) = 359.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2011 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 577.9 kN
Design shear capacity; Vn = v  Vn = 433.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/6 96
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.830
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD16) = 239.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 611.2 kN
Design shear capacity; Vn = v  Vn = 458.4 kN
Vu / Vn = 0.523
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD16) = 11.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2066 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 593.7 kN
Design shear capacity; Vn = v  Vn = 445.3 kN
Vu / Vn = 0.025
PASS - Design shear capacity exceeds ultimate shear load

(12) 19 mm  top bars (152 mm c/c)

(12) 19 mm  bot bars (152 mm c/c)


(12) 19 mm  bot bars (152 mm c/c)
(12) 19 mm  top bars (152 mm c/c)
1800 mm

1800 mm

;
;

You might also like