Download as pdf or txt
Download as pdf or txt
You are on page 1of 207

5 Port Solenoid Valve New

Increased Flow For The SY Series


SY3000

ø32 [Conventional] Increased up to ø50 (300 mm/s)

10 mm width can drive a ø50 cylinder.


SY5000

ø50 [Conventional] Increased up to ø63 (300 mm/s)

15 mm width can drive a ø63 cylinder.

Values based on comparison with the conventional SMC model. Refer to page 4 for common conditions.

Thanks to the flow increase, valve size can


be reduced. Saves energy and space.
New
uAdded the EX260 Integrated-type (For Output)
Serial Transmission System.
uAdded EtherNet/IP™, EtherCAT to the EX600
Integrated-type (For Input/Output) Serial
Transmission System (Fieldbus System).
uAdditional Options:
Interface regulator assembly
Individual SUP block assembly
Individual EXH block assembly
Dual flow fitting
Name plate for manifolds

Power Consumption [Electrical power waveform with power saving circuit] Rubber seal
Metal seal
0.1w 0.35w
With power saving circuit Standard
24 V
Applied voltage

0V
Life
Power consumption is reduced by Standard
power saving circuit.
0.35 (0.9) W
With power
saving circuit
70 million cycles
Power consumption is decreased by approx. 1/3 0.1 (0.4) W (Rubber seal)
by reducing the wattage required to hold the
valve in an energized state. (Effective energizing
time is over 67 ms at 24 VDC.) Refer to the
0W
67 ms (40 ms) 200 million cycles
(Metal seal)
electrical power waveform as shown on the right. The value in ( ) are for the quick response and high pressure types.
According to SMC life test conditions

Series SY3000/5000
CAT.ES11-103B
5 Port Solenoid Valve Series SY3000/5000
Plug-in metal base [IP40] Plug-in connector connecting base [IP67Note)] # Connector type manifold
Plug-in

Connector type manifold


Note) Refer to page 6 for 32 outputs
details on IP67.

Space saving / Improved operability


Wiring, piping and operation are Bottom ported is prepared. Space saving
integrated on one side. Bottom ported reduces the footprint.
Multiple layer type is available as an option. This saves
space in the lateral direction. Installation
Can be operated
from the top.

SUP stop valve spacer with


residual pressure release valve

Individual SUP/EXH spacer

Direction, size and type of the piping can be changed.


To mount the piping on top To mount Mixed mounting of
Port block assembly
One-touch fitting the piping Replace the top ported and side
for A, B port on the side fitting and the ported is possible.
Body cover port plug only.
Thread piping assembly Top ported

Cover assembly

Port block assembly Side ported


for P, E port
It is possible to detect the output of A and B
port with a pressure switch by mounting the
top ported valve onto the side ported or
bottom ported manifold.

Back pressure check valve Pressure switch

This prevents cylinder malfunction caused by the exhaust from other valves.
Retrofit or pre-installed type
Built-in valve type Back pressure check valve
(Check seal) If the product is affected by back pressure after
installation, the back pressure check valve
assembly can be added.
(A)(B)
4 2

5 1 3
(EA)(P)(EB)
5 4 1 2 3
(EA) (A) (P) (B) (EB)

Back pressure check valve assembly


Features 1
Double check spacer SUP stop valve spacer
with residual pressure release valve with residual pressure release valve
Long time of intermediate stop and position holding are possible. Air supply to each valve can be stopped individually. The
[Intermediate stop] [Drop prevention] valve and cylinder can be replaced without stopping
Button for manual release other devices and equipment.
of residual pressure Double check spacer assembly Double check spacer assembly
Button for manual release
To exhaust residual of residual pressure
pressure on
cylinder side. To exhaust residual 2-position single valve
4(A)
pressure on 2(B)
cylinder side.
SUP stop valve
spacer assembly

4 (A) 2 (B) 4 (A) 2 (B)


5 (EA) 5 (EA)
1 (P) 1 (P) 5(EA)
3 (EB) 3 (EB) 1(P)
3(EB)

Exhaust center 2-position single/double 2-position single valve example

Applicable to various type of serial wiring


Series Applicable protocol Series Applicable protocol
EX510 폷DeviceNet™
EX260 폷DeviceNet™
Gateway-type Integrated-type
폷PROFIBUS DP 폷PROFIBUS DP
Serial Transmission New (For Output)
폷CC-Link
System 폷CC-Link Serial Transmission
폷EtherCAT
System
폷PROFINET
EX500 폷DeviceNet™
Gateway-type
폷PROFIBUS DP
Serial Transmission
폷CC-Link EX126 Integrated-type
System
폷EtherNet/IP™ (For Output)
폷CC-Link
Serial Transmission
EX600 Integrated-type 폷DeviceNet™ System
(For Input/Output) 폷PROFIBUS DP
Serial Transmission 폷CC-Link
System New 폷
EtherNet/IP™
EX120
Integrated-type 폷DeviceNet™
(Fieldbus System) New 폷EtherCAT (For Output) 폷CC-Link
Serial Transmission 폷OMRON CompoBus/S
EX250 폷DeviceNet™ System 폷CompoNet™
Integrated-type 폷PROFIBUS DP
(For Input/Output) 폷CANopen
Serial Transmission 폷CC-Link
System 폷AS-Interface
폷EtherNet/IP™

Slide manual override provides better visibility. 4-position dual 3-port valve available
ON/OFF operation and locking (Only rubber seal type)
can be performed with the OFF • Two 3-port valves built into one body
manual slide. • 3-port valves on the A and B sides can operate
ON independently.
• When used as a 3-port valve, only half the number of
stations is required.
• Can also be used as a 4-position, 5-port valve.
• 4-position dual 3-port valve with back pressure check
valve is available.
B-side manual A-side manual
override override
(Yellow) (Blue) A side B side JIS symbol
(A) (B)
4 2
N.C. N.C.
SOL.a
valve valve 5 SOL.b
3
(EA) 1 (EB)
(P)

ON/OFF state can be checked at a glance. (A)


4
(B)
2
N.O. N.O.
SOL.a SOL.b
B-side manual A-side manual valve valve 5
(EA) 3
1 (EB)
(P)
override override
ON OFF (A)
4
(B)
2
N.C. N.O.
SOL.a SOL.b
valve valve 5
(EA) 3
1 (EB)
(P)

Features 2
Manifold Variations
Wiring
Common
Connection specification
Valve
Series Serial transmission

Terminal block box

Circular connector

Negative common
Positive common
Flat ribbon cable
D-sub connector

Lead wire
PC wiring
Manifold Variations

EX510
EX500
EX600
EX250
EX260
EX126
EX120
5 ports
Top ported Bottom ported Side ported Top ported Bottom ported Side ported

Type SY3쏔0쏔
— — — — — — — — —
Plug-in Metal Base

50쏔
SY5쏔0쏔 P. 15 P. 15 P. 15 P.35

Type SY3쏔0쏔
— — — — — — — — —
51쏔 SY5쏔0쏔 P. 15 P. 15 P. 15 P.35

Type SY3쏔3쏔
— — — — — — — — —
52쏔 SY5쏔3쏔 P. 29 P. 29 P. 29 P.43
Plug-in Connector Connecting Base

SY3쏔0쏔
Type

10쏔 SY5쏔0쏔 P. 49 P. 49 P. 49 P. 59 P. 67 P. 75 P. 83 P. 89 P. 97 P. 103 P. 109 P. 115

Type SY5쏔0쏔 —
11쏔
P. 49 P. 49 P. 49 P. 59 P. 67 P. 75 P. 83 P. 89 P. 97 P. 103 P. 109 P. 115

SY3쏔3쏔
Type —
12쏔 SY5쏔3쏔 P. 55 P. 55 P. 55 P. 63 P. 71 P. 79 P. 87 P. 95 P. 101 P. 107 P. 113 P. 119
Standard 쑗 Option 왖 Made-to-Order (Refer to page 14.)

쎲Wiring
Plug-in Metal Base Plug-in Connector Connecting Base
D-sub connector Flat ribbon cable, Serial transmission: D-sub connector
PC wiring EX510

[IP40] [IP40] [IP20] [IP40]

Plug-in Connector Connecting Base


Circular connector Serial transmission: Serial transmission: Serial transmission:
EX500 EX600 EX250

[IP67]
[IP67] [IP67] ∗Partially IP40 [IP67]

1
Manifold Options (Pages 141 to 148) A, B Port Size Valve Options
SUP stop valve spacer with residual pressure release valve

SY3000/5000 mixed mounting


Back pressure check valve assembly
Double check spacer with residual pressure release valve

Silencer (One-touch fitting connection type)

Oil resistant (Other than designated turbine oil)


Individual EXH block assembly
Individual SUP block assembly

Low pressure specification


One-touch fittings

SUP/EXH blocking disk


Label for blocking disk
Individual SUP spacer
Individual EXH spacer

Vacuum specification

Different pressures
Interface regulator

Mixed fitting sizes


Reverse pressure
Exhaust throttle
Dual flow fitting

Enclosure IP67
Blanking plate

C2 C3 C4 C6 C8

Plug (White)
Name plate
(N1) (N3) (N7) (N9)

Note 1)

Note 1)

Note 1)
M5 1/8 1/4

Straight piping
Straight piping
Straight piping

Straight piping

Straight piping
Elbow piping

Elbow piping

Elbow piping
External External Individual External Individual
Pilot Pilot SUP Pilot EXH

Individual Individual
SUP EXH

External External Individual External Individual


Pilot Pilot SUP Pilot EXH

Note 2)

External External Individual External Individual


P.127 Pilot Pilot SUP Pilot EXH

Note 2)

External External Individual External Individual


P.127 Pilot Pilot SUP Pilot EXH

Note 2)

External External Individual External Individual


P.131 Pilot Pilot SUP Pilot EXH
Note 1): Elbow piping may specify size only in millimeters, depending on the port size. Refer to How to Order Manifold for details.
Note 2): Refer to Manifold Specifications for details on IP67.

쏹One-touch fittings
Straight piping
Flat ribbon cable, Terminal block box Lead wire
PC wiring

[IP40] [IP67] [IP67]

Elbow piping

Serial transmission: Serial transmission: Serial transmission:


EX260 EX126 EX120

[IP67]
∗Partially IP40 [IP67] [IP20]

2
Manifold Variations P. 1
Optimum Actuation Size Chart of Air Cylinder P. 4
Plug-in Metal Base P. 5
Plug-in Connector Connecting Base P. 6
Valve Specifications (Specifications, Response Time, Weight) P. 8
Valve Construction P. 10
Valve Replacement Parts P. 13
Made-to-Order for Valve P. 14

Plug-in Metal Base


Type 50/ Type 51/ Type 52/
Side ported Bottom ported Top ported

Type 50/Side Ported, Type 51/Bottom Ported, Type 52/Top Ported P. 15


D-sub Connector, Flat Ribbon Cable, PC Wiring System [IP40]
Type 50/Side Ported P. 15
Type 51/Bottom Ported P. 15
D-sub connector
Type 52/Top Ported P. 29
Flat ribbon cable
Wiring Specifications P. 33
EX510 Gateway-type Serial Transmission System [IP20]
Type 50/Side Ported P. 35
PC wiring Type 51/Bottom Ported P. 35
EX510 Type 52/Top Ported P. 43
Manifold Exploded View [Exploded View, Manifold Parts No.] P. 47

Plug-in Connector Connecting Base LOCK

FREE
LOCK

FREE

Type 10/ Type 11/ Type 12/


Side ported Bottom ported Top ported

Type 10/Side Ported, Type 11/Bottom Ported, Type 12/Top Ported P. 49


D-sub PC
connector wiring D-sub Connector, Flat Ribbon Cable, PC Wiring System [IP40] P. 49
Terminal Block Box [IP67] P. 59
Terminal Lead Wire [IP67] P. 67
Flat ribbon
block box
cable Circular Connector [IP67] P. 75
Circular EX500 Gateway-type Serial Transmission System [IP67] P. 83
connector
Lead wire EX600 Integrated-type (For Input/Output) Serial Transmission System (Fieldbus System) [IP67] P. 89
EX250 Integrated-type (For Input/Output) Serial Transmission System [IP67] P. 97
EX500 EX600
EX260 Integrated type (For Output) Serial Transmission System [IP67] P. 103
EX126 Integrated-type (For Output) Serial Transmission System [IP67] P. 109
EX250 EX260 EX120 Integrated-type (For Output) Serial Transmission System [IP20] P. 115
Type 11/Bottom Ported Common Dimensions P. 123
Type 12/Top Ported Common Dimensions P. 124
EX126 EX120 Plug-in 3000/5000 Manifold Mixed Mounting Type P. 127
Manifold Exploded View [Exploded View, Manifold Parts No.] P. 134
Mixed
mounting How to Increase Connector Type Manifold P. 138
One-touch Fittings, Plug Assembly/Part No. P. 139
Manifold Options [Plug-in Metal Base, Plug-in Connector Connecting Base] P. 140
Specific Product Precautions P. 153
Safety Instructions Back cover
3
Construction Specifications
Optimum Actuation Size Chart of Air Cylinder

Applicable cylinder

Replacement
Applicable Main valve
Series
cylinder speed seal type

Parts
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø50 ø63 ø80 ø100 ø125

Metal Base
SY3000

Plug-in
Rubber seal
SY5000

Flat Ribbon Cable


D-sub Connector
100 mm/s or less

PC Wiring
SY3000

EX510
Metal seal
SY5000

Terminal D-sub Connector Plug-in Connector


Connecting Base
SY3000
Rubber seal

Flat Ribbon Cable


SY5000

Block Box PC Wiring


300 mm/s or less
SY3000
Metal seal
SY5000

Lead Wire
SY3000

Connector
Circular
Rubber seal
SY5000

EX120 EX126 EX260 EX250 EX600 EX500


500 mm/s or less
SY3000
Metal seal
SY5000

[Common conditions]
• Pressure: 0.5 MPa
• Piping length: 1 m
• Load ratio: 50%
• Stroke: 200 mm
• Connector type manifold Side and bottom ported type
∗ Use as a guide for selection.
Please check the actual conditions with SMC Sizing Program.
and Plug Assembly/
One-touch Fittings

Part No.
Manifold
Options
Specific Product
Precautions

4
Series SY3000/5000 Type 50, 51, 52
Plug-in Metal Base
Manifold Specifications

D-sub connector Flat ribbon cable Serial wiring


Model PG type S5 type
F type P type PH type
J type (EX510)
Manifold type Plug-in metal base
SUP/EXH port type Common SUP/EXH
2 to 9 stations
All double wiring 2 to 4 stations 2 to 8 stations
Valve stations 2 to 12 stations (J type: 2 to 8 stations)
All single wiring 2 to 12 stations 2 to 8 stations 2 to 12 stations

Flat ribbon cable connector


D-sub connector with strain relief
Conforming to Conforming to MIL-C-83503
Applicable connector —
MIL-C-24308
JIS-X-5101 Socket: 26 pins Socket: 20 pins Socket: 10 pins
MIL type MIL type MIL type
Internal wiring Positive common, Negative common
SY3000 1/8
1(P), 3/5(E) port
SY5000 1/4

M5 x 0.8, 1/8
SY3000 ø2 One-touch fitting, ø3.2 One-touch fitting, ø4 One-touch fitting, ø6 One-touch fitting
Port size
ø1/8" One-touch fitting, ø5/32" One-touch fitting, ø1/4" One-touch fitting
4(A), 2(B) port
1/8, 1/4
SY5000 ø4 One-touch fitting, ø6 One-touch fitting, ø8 One-touch fitting
ø5/32" One-touch fitting, ø1/4" One-touch fitting, ø5/16" One-touch fitting

Enclosure (Based on IEC60529) IP40 IP20

Manifold Flow-rate Characteristics Note 1)/Manifold Weight


Valve Seal Type: Rubber Seal
Port size Valve flow-rate characteristics Weight: W [g] Note 2)
Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b Fixed: C쏔 Replaceable: KC쏔
SS5Y3-50 (Side ported) 01 C6 1.1 0.19 1.1 0.15 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 01 C6 1.2 0.31 1.2 0.14 41.5n + 251 48.5n + 251
SS5Y3-52 (Top ported) 01 C6 1.1 0.29 1.2 0.20 44n + 247
SS5Y5-50 (Side ported) 02 C8 2.6 0.28 2.6 0.14 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 02 C8 2.7 0.35 2.8 0.20 93n + 413 113n + 413
SS5Y5-52 (Top ported) 02 C8 2.6 0.26 3.1 0.13 103n + 379

Valve Seal Type: Metal Seal


Port size Valve flow-rate characteristics Weight: W [g] Note 2)
Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b Fixed: C쏔 Replaceable: KC쏔
SS5Y3-50 (Side ported) 01 C6 0.9 0.14 1.0 0.12 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 01 C6 1.0 0.21 1.1 0.10 41.5n + 251 48.5n + 251
SS5Y3-52 (Top ported) 01 C6 1.1 0.15 1.1 0.14 44n + 247
SS5Y5-50 (Side ported) 02 C8 2.2 0.20 2.3 0.13 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 02 C8 2.4 0.26 2.5 0.16 93n + 413 113n + 413
SS5Y5-52 (Top ported) 02 C8 2.4 0.18 2.6 0.12 103n + 379
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
Note 1) The value is for manifold base with 5 stations and individually operated 2-position type.
Note 2) Weight: W is the value for the D-sub connector manifold.
To obtain the weight with valves attached, add the valve weights given on page 9 for the appropriate number of stations.

5
Series SY3000/5000 Type 10, 11, 12

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Manifold Specifications

Metal Base
D-sub Terminal Circular
Flat ribbon cable Lead wire Serial wiring

Plug-in
connector block box connector
Model SA2 type S쏔 type
PG type S6쏔 type (EX500) S3쏔 type
F type P type PH type T type L type M type (EX250)
J type (EX600) S4쏔 type (EX120)

Flat Ribbon Cable


D-sub Connector
(EX126) (EX260)

PC Wiring
Manifold type Plug-in connector connecting base
SUP/EXH port type Common SUP/EXH (Common for 3/5 port)

EX510
2 to18
stations 2 to 8 2 to 20 2 to 16 2 to 24 2 to 16
Valve stations 2 to 24 stations (J type: 2 to 24 stations
2 to 16 stations stations stations stations stations
stations)

Terminal D-sub Connector Plug-in Connector


Connecting Base
Flat ribbon cable connector
D-sub
with strain relief
connector
Conforming to MIL-C-83503
Applicable connector Conforming to —
Socket: Socket: Socket:
MIL-C-24308
26 pins 20 pins 10 pins

Flat Ribbon Cable


JIS-X-5101
MIL type MIL type MIL type

Block Box PC Wiring


Internal wiring Positive common, Negative common
ø8 One-touch fitting
SY3000
1(P), 3/5(E) ø5/16" One-touch fitting
port ø10 One-touch fitting
SY5000
Port ø3/8" One-touch fitting

Lead Wire
size ø2 One-touch fitting, ø3.2 One-touch fitting, ø4 One-touch fitting, ø6 One-touch fitting
SY3000
4(A), 2(B) ø1/8" One-touch fitting, ø5/32" One-touch fitting, ø1/4" One-touch fitting
port

Connector
ø4 One-touch fitting, ø6 One-touch fitting, ø8 One-touch fitting
SY5000

Circular
ø5/32" One-touch fitting, ø1/4" One-touch fitting, ø5/16" One-touch fitting
IP67
IP67
)( )
EX500 gateway IP67

EX120 EX126 EX260 EX250 EX600 EX500


Enclosure (Based on IEC60529) IP40 IP67 IP20
( I/O unit: unit, input unit: (Partially IP40)
partially IP40 IP65

Manifold Flow-rate Characteristics Note 1)/Manifold Weight


Valve Seal Type: Rubber Seal
Port size Valve flow-rate characteristics
Weight: W [g] Note 2)
Model 1, 3/5 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E)
(n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SS5Y3-10 (Side ported) C8 C6 1.4 0.30 1.6 0.19 28.9n + 293
SS5Y3-12 (Top ported) C8 C6 1.2 0.29 1.3 0.19 25.1n + 314
SS5Y5-10 (Side ported) C10 C8 3.3 0.30 3.6 0.17 74.7n + 398
SS5Y5-11 (Bottom ported) C10 C8 3.3 0.29 4.2 0.26 76.8n + 445
SS5Y5-12 (Top ported) C10 C8 2.8 0.27 3.8 0.23 66.3n + 417

Valve Seal Type: Metal Seal


Port size Valve flow-rate characteristics
Weight: W [g] Note 2)
Model 1, 3/5 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E)
(n: stations)
(P, E) (A, B)
and Plug Assembly/

C [dm3/(s·bar)] b C [dm3/(s·bar)] b
One-touch Fittings

SS5Y3-10 (Side ported) C8 C6 1.2 0.19 1.3 0.18 28.9n + 293


Part No.

SS5Y3-12 (Top ported) C8 C6 1.2 0.16 1.3 0.18 25.1n + 314


SS5Y5-10 (Side ported) C10 C8 2.7 0.24 3.1 0.17 74.7n + 398
Manifold
Options

SS5Y5-11 (Bottom ported) C10 C8 2.8 0.25 3.5 0.15 76.8n + 445
SS5Y5-12 (Top ported) C10 C8 2.6 0.18 3.0 0.16 66.3n + 417
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
Specific Product

Note 1) The value is for manifold base with 5 stations and individually operated 2-position type.
Precautions

Note 2) Weight: W is the value of the internal pilot, and D-sub connector manifold with one-touch fitting straight piping type.
To obtain the weight with valves attached, add the valve weights given on page 9 for the appropriate number of stations.

6
Series SY3000/5000

Connector Wiring Layout


For both serial and parallel wiring, additional valves are sequentially assigned pins on the connector.
This makes it completely unnecessary to disassemble the connector unit.

왎 Single solenoid valve is installed to all double wiring. (in case of all double wiring)
(Manifold specification sheet is not necessary.)

Solenoid Connector side


(D-sub connector, etc.)

Common (+, –)
SOL.a Station 1
SOL.b
SOL.a Station 2
Unused terminal
SOL.a Station 3
SOL.b

Double solenoid Single solenoid Double solenoid


Station 3 (Double wiring) Station 1
Station 2

왎 Single/double wiring are mixed.


(Manifold specification sheet is necessary.)

Solenoid Connector side


(D-sub connector, etc.)

Common (+, –)
SOL.a Station 1
SOL.b
SOL.a Station 2
SOL.a Station 3
SOL.b

Double solenoid Single solenoid Double solenoid


Station 3 Station 2 Station 1

Note) These diagrams are for the purpose of explanation, and differ from the connector wiring used for testing.

7
Construction Specifications
Series SY3000/5000
Valve Specifications 1

Replacement
Parts
Valve Specifications

Metal Base
Valve type Rubber seal Metal seal

Plug-in
Fluid Air
2-position single 0.15 to 0.7
Internal pilot
2-position double 0.1 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to 1)
operating pressure range

Flat Ribbon Cable


3-position 0.2 to 0.7

D-sub Connector
(MPa)
4-position dual 3-port valve 0.15 to 0.7 —

PC Wiring
Operating pressure range –100 kPa to 0.7 (4-position: –100 kPa to 0.6) –100 kPa to 0.7 (High pressure type: –100 kPa to 1)
External pilot 2-position single

EX510
Pilot
operating pressure range 2-position double 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to 1)
pressure
(MPa) 3-position
range
4-position dual 3-port valve Operating pressure + 0.1 or more (Min. 0.25) to 0.7 —
Ambient and fluid temperature (°C) –10 to 50 (No freezing)

Terminal D-sub Connector Plug-in Connector


Connecting Base
2-position single/double
Max. operating frequency 5 20 Note 1)
4-position dual 3-port valve
(Hz)
3-position 3 10 Note 1)
Non-locking push type
Manual override Push-turn locking slotted type

Flat Ribbon Cable


Slide locking type

Block Box PC Wiring


Internal pilot Main/Pilot valve common exhaust
Pilot exhaust type
External pilot Pilot valve individual exhaust
Lubrication Not required
Single: Unrestricted
Mounting orientation Unrestricted
Double/3-position: Main valve is horizontal.

Lead Wire
Impact/Vibration resistance Note 2) (m/s2) 150/30
Enclosure IP67 (Based on IEC60529)
Coil rated voltage (DC) 24, 12 V
Allowable voltage fluctuation (V) ±10% of rated voltage Note 3)

Connector
Circular
Standard 0.35 (With indicator light: 0.4)
Power consumption (W) High pressure type, Quick response type 0.9 (With indicator light: 0.95)
With power saving circuit Standard: 0.1 (With indicator light only), High pressure type: 0.4 (With indicator light only)

EX120 EX126 EX260 EX250 EX600 EX500


Surge voltage suppressor Diode (Varistor for non-polar type)
Indicator light LED
Note 1) Use below 5 Hz for with power saving circuit.
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and armature in both energized and
de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in
the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 3) Due to voltage drops by the internal circuit in S/Z type and T type (with power saving circuit), use within the allowable voltage fluctuation as follows.
24 VDC: –7% to +10% 24 VDC: –8% to +10%
S/Z type T type
12 VDC: –4% to +10% 12 VDC: –6% to +10%

Response Time

Response time (ms)


Standard Quick response type
Series Seal type Model Type of actuation Without light/ With light/surge Without light/ With light/surge
surge voltage voltage suppressor surge voltage voltage suppressor
suppressor S/Z type R/U type suppressor S/Z type R/U type
Rubber seal SY31쏔0 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
2-position single
Metal seal SY31쏔1 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
Rubber seal SY32쏔0 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY3000 Metal seal SY32쏔1 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
and Plug Assembly/
One-touch Fittings

Rubber seal SY33/4/5쏔0 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less


3-position
Metal seal SY33/4/5쏔1 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less
Part No.

Rubber seal SY3A/B/C쏔0 4-position dual 3-port valve 18 or less 22 or less 18 or less 15 or less 19 or less 15 or less
Rubber seal SY51쏔0 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less
Manifold

2-position single
Options

Metal seal SY51쏔1 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less


Rubber seal SY52쏔0 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY5000 Metal seal SY52쏔1 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY53/4/5쏔0 30 or less 34 or less 30 or less 24 or less 28 or less 24 or less
Specific Product

3-position
Metal seal SY53/4/5쏔1 28 or less 30 or less 28 or less 23 or less 25 or less 23 or less
Precautions

Rubber seal SY5A/B/C쏔0 4-position dual 3-port valve 35 or less 42 or less 35 or less 28 or less 35 or less 28 or less

8
Series SY3000/5000
Valve Specifications 2
Valve Weight
Series SY3000
Valve model Seal type Type of actuation Weight g Valve model Seal type Type of actuation Weight g
Single 74 Single 76
2-position 2-position
Double 83 Double 86
Closed center SY3쏔01 Metal seal Closed center
SY3쏔00 Rubber seal
3-position Exhaust center 87 3-position Exhaust center 90
Pressure center Pressure center
4-position Dual 3-port valve 83

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) g type 4, 2 (A, B) g
Single 74 Single 76
2-position 2-position
Double 83 Double 86
SY3쏔30-M5 Closed center
M5 x 0.8
SY3쏔31-M5 Closed center M5 x 0.8
3-position Exhaust center 87 3-position Exhaust center 90
Pressure center Pressure center
4-position Dual 3-port valve 83 Single 84
2-position
Single 82 Double C2 94
2-position
Double
C2
91 SY3쏔31-C2 Closed center ø2 One-touch
Closed center 3-position Exhaust center fitting 98
SY3쏔30-C2 ø2 One-touch
3-position Exhaust center 95 Pressure center
fitting
Pressure center Single 87
2-position
4-position Dual 3-port valve 91 Double C3 97
Metal
Single 85 SY3쏔31-C3 seal Closed center ø3.2 One-touch
2-position
Double 94 3-position Exhaust center fitting 101
C3
Rubber Closed center Pressure center
SY3쏔30-C3 ø3.2 One-touch
seal 3-position Exhaust center 98 Single 79
fitting 2-position
Pressure center Double C4 89
4-position Dual 3-port valve 94 SY3쏔31-C4 Closed center ø4 One-touch
Single 77 3-position Exhaust center fitting 93
2-position
Double 86 Pressure center
C4
Closed center Single 82
SY3쏔30-C4 ø4 One-touch 2-position
3-position Exhaust center 90 Double C6 92
fitting
Pressure center SY3쏔31-C6 Closed center ø6 One-touch
4-position Dual 3-port valve 86 3-position Exhaust center fitting 96
Single 80 Pressure center
2-position
Double 89
C6
Closed center
SY3쏔30-C6 ø6 One-touch
3-position Exhaust center 93
fitting
Pressure center
4-position Dual 3-port valve 89

Series SY5000
Valve model Seal type Type of actuation Weight g Valve model Seal type Type of actuation Weight g
Single 82 Single 91
2-position 2-position
Double 90 Double 101
Closed center SY5쏔01 Metal seal Closed center
SY5쏔00 Rubber seal
3-position Exhaust center 3-position Exhaust center
100 111
Pressure center Pressure center
4-position Dual 3-port valve 90

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) g type 4, 2 (A, B) g
Single 102 Single 111
2-position 2-position
Double 110 Double 121
Closed center SY5쏔31-01 Closed center 1/8
SY5쏔30-01 3-position Exhaust center
1/8
Exhaust center
120 3-position 131
Pressure center Pressure center
4-position Dual 3-port valve 110 Single 124
2-position
Single 115 Double C4 134
2-position
Double
C4
123 SY5쏔31-C4 Closed center ø4 One-touch
Closed center 3-position Exhaust center fitting 144
SY5쏔30-C4 3-position Exhaust center
ø4 One-touch
Metal Pressure center
133
fitting
Pressure center seal Single 120
2-position
Rubber 4-position Dual 3-port valve 123 Double C6 130
seal
2-position
Single 110 SY5쏔31-C6 Closed center ø6 One-touch
Double 118 3-position Exhaust center fitting 140
C6
Closed center Pressure center
SY5쏔30-C6 3-position Exhaust center
ø6 One-touch
Single
128 108
fitting 2-position
Pressure center Double C8 118
4-position Dual 3-port valve 118 SY5쏔31-C8 Closed center ø8 One-touch
Single 99 3-position Exhaust center fitting 128
2-position
Double 107 Pressure center
C8
Closed center
SY5쏔30-C8 3-position Exhaust center
ø8 One-touch
117
fitting
Pressure center
4-position Dual 3-port valve 107
9
Construction Specifications
Series SY3000/5000
Valve Construction 1

Replacement
Parts
Rubber Seal
2-position single Top ported

Metal Base
(A) (B)
4 2

Plug-in
t e q w r t e q w r

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
2-position single
5 4 1 2 3 5 1 3 (A) (B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB) 4 2

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 1 3
(EA)(P)(EB)

Flat Ribbon Cable


2-position double

Block Box PC Wiring


t e q w r

Lead Wire
2-position double
5 4 1 2 3 (A) (B)

Connector
(EA) (A) (P) (B) (EB) 4 2

Circular
5 1 3
(EA)(P)(EB)

EX120 EX126 EX260 EX250 EX600 EX500


3-position closed center/exhaust center/pressure center
t e q w r 3-position closed center 3-position exhaust center
(A) (B) (A) (B)
4 2 4 2

5 1 3 5 1 3
(EA)(P)(EB) (EA)(P)(EB)

3-position pressure center


(A) (B)
5 4 1 2 3 4 2
(EA) (A) (P) (B) (EB)

5 1 3
(EA)(P)(EB)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
and Plug Assembly/

SY5000: Aluminum die-casted


One-touch Fittings

Special resin/HNBR
Part No.

2 Spool valve 3-position valve:


(
Aluminum/HNBR )
Manifold
Options

3 Piston Resin
Body cover assembly Resin For side/bottom ported

4 Resin
Port block assembly SY5000 series threaded type: For top ported
( )
Specific Product

Zinc die-casted
Precautions

5 Pilot valve assembly — Refer to page 14.

10
Series SY3000/5000
Valve Construction 2
Rubber Seal
4-position dual 3-port valve
4-position dual 3-port valve
N.C. valve x 2 pcs. N.O. valve x 2 pcs.
t e q w r (A) (B) (A) (B)
4 2 4 2

SOL.a SOL.b SOL.a SOL.b


5 5
(EA) 3 (EA) 3
1 (EB) 1 (EB)
(P) (P)

N.C. valve, N.O. valve 1 pc. of each


5 4 1 2 3 (A) (B)
(EA) (A) (P) (B) (EB) 4 2

SOL.a SOL.b
5
(EA) 3
1 (EB)
(P)

2-position double with back pressure check valve (Built-in valve type)

t e q w r
2-position double
with back pressure check valve
(A) (B)
4 2

5 1 3
(EA)(P)(EB)
5 4 1 2 3
(EA) (A) (P) (B) (EB)

4-position dual 3-port valve with back pressure check valve (Built-in valve type)

4-position dual 3-port valve with back pressure check valve


t e q w r N.C. valve x 2 pcs. N.O. valve x 2 pcs.
(A) (B) (A) (B)
4 2 4 2

SOL.a SOL.b SOL.a SOL.b


5 5
(EA) 3 (EA) 3
1 (EB) 1 (EB)
(P) (P)

5 4 1 2 3 N.C. valve, N.O. valve 1 pc. of each


(EA) (A) (P) (B) (EB) (A) (B)
4 2

SOL.a SOL.b
5
(EA) 3
1 (EB)
(P)

11
Construction Specifications
Series SY3000/5000
Valve Construction 3

Replacement
Parts
Metal Seal
2-position single Top ported

Metal Base
(A) (B)
4 2

Plug-in
t e q w r t e q w r

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
2-position single
5 4 1 2 3 5 1 3 (A) (B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB) 4 2

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 1 3
(EA)(P)(EB)

Flat Ribbon Cable


2-position double

Block Box PC Wiring


t e q w r

Lead Wire
2-position double
5 4 1 2 3 (A) (B)

Connector
(EA) (A) (P) (B) (EB) 4 2

Circular
5 1 3
(EA)(P)(EB)

EX120 EX126 EX260 EX250 EX600 EX500


3-position closed center/exhaust center/pressure center
t e q w r

3-position closed center 3-position exhaust center


(A) (B) (A) (B)
4 2 4 2

5 1 3 5 1 3
(EA)(P)(EB) (EA)(P)(EB)
5 4 1 2 3
(EA) (A) (P) (B) (EB) 3-position pressure center
(A) (B)
4 2

5 1 3
(EA)(P)(EB)

Component Parts
and Plug Assembly/
One-touch Fittings

No. Description Material Note


SY3000: Zinc die-casted
1 Body
Part No.

SY5000: Aluminum die-casted


2 Spool, Sleeve Stainless steel/HNBR
Manifold
Options

3 Piston Resin
Body cover assembly Resin For side/bottom ported
Resin
4
SY5000 series threaded type: For top ported
Port block assembly
( )
Specific Product

Zinc die-casted
Precautions

5 Pilot valve assembly — Refer to page 14.

12
Series SY3000/5000
Valve Replacement Parts 1
How to Order Port Block Assembly
Mounting screw

SY 0V 6A One-touch fitting

Series Thread type


3 3000 Nil Rc
5 5000 F G
N NPT
Pilot type T NPTF
Nil Internal pilot ∗ Except M5
R External pilot
A, B port size
Thread piping
Option for mounting Symbol Port size Applicable series
Nil Standard (Valve mounting screw “not” falling-out-prevention type) M5 M5 x 0.8 SY3000
1 Valve mounting screw falling-out-prevention type 01 1/8 SY5000
One-touch fitting (Metric)
Applicable series
Symbol Port size
SY3000 SY5000
C2 ø2 One-touch fitting
C3 ø3.2 One-touch fitting
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
One-touch fitting (Inch)
Applicable series
Symbol Port size
SY3000 SY5000
N1 ø1/8" One-touch fitting
N3 ø5/32" One-touch fitting
N7 ø1/4" One-touch fitting
N9 ø5/16" One-touch fitting

쎲 Possible to replace only the one-touch fitting.


Port size SY3000 SY5000
ø2 One-touch fitting VVQ1000-50A-C2 —
ø3.2 One-touch fitting VVQ1000-50A-C3 —
Metric size ø4 One-touch fitting VVQ1000-50A-C4 VVQ1000-51A-C4
ø6 One-touch fitting VVQ1000-50A-C6 VVQ1000-51A-C6
ø8 One-touch fitting — VVQ1000-51A-C8
ø1/8" One-touch fitting VVQ1000-50A-N1 —
Refer to pages 156 and 157 for how to ø5/32" One-touch fitting VVQ1000-50A-N3 VVQ1000-51A-N3
replace the port block assembly, one-
Inch size
ø1/4" One-touch fitting VVQ1000-50A-N7 VVQ1000-51A-N7
touch fitting and body cover assembly. ø5/16" One-touch fitting — VVQ1000-51A-N9

Body Cover Assembly


∗ Used when the top ported is changed to the side or bottom ported.

Mounting screw

Part no.
Series
Standard (Valve mounting screw “not” falling-out-prevention type) Valve mounting screw falling-out-prevention type
Internal pilot SY30V-16A SY30V-16A-1
SY3000
External pilot SY30V-16AR SY30V-16AR-1
Internal pilot SY50V-16A SY50V-16A-1
SY5000
External pilot SY50V-16AR SY50V-16AR-1
13
Construction Specifications
Series SY3000/5000
Valve Replacement Parts 2

Replacement
Parts
How to Order Pilot Valve Assembly (With a gasket and two mounting screws)

Metal Base
V112 A How to replace pilot valves

Plug-in
Pilot cover assembly
Pilot valve option Series Part no.
SY3000 SY30V-25A Gasket

Flat Ribbon Cable


D-sub Connector
Nil Standard (0.7 MPa)
SY5000 SY50V-25A

PC Wiring
B Quick response type (0.7 MPa) a-side pilot valve
∗ Pilot cover x 1 + B tight flat
K High pressure type (1.0 MPa)∗ head screw x 1

EX510
∗ Only metal seal type is available for
the high pressure type. (1.0 MPa) w
Pilot cover
Coil type

Terminal D-sub Connector Plug-in Connector


Connecting Base
Nil Standard Socket
T With power saving circuit q w
b-side pilot valve
Rated voltage
5 24 VDC B tight flat head screw (M1.7)

Flat Ribbon Cable


6 12 VDC Tightening torque: 0.12 N·m Pilot valve mounting screw (M2 x 16.5)

Block Box PC Wiring


Tightening torque: 0.15 N·m

Caution Pilot valve mounting screw (M2 x 25)


The coil specification and voltage (including Tightening torque: 0.15 N·m
light/surge voltage suppressor) cannot be
changed by changing the pilot valve assembly.

Lead Wire
• Loosen B tight flat head screw to remove the pilot cover in the direction
indicated by the arrow q.
• Remove the pilot valve mounting screws.

Connector
• Remove the pilot valve in the direction indicated by the arrow w.

Circular
∗ Assemble by following the removal procedure in reverse.

EX120 EX126 EX260 EX250 EX600 EX500


Note 1) Ensure the gasket is mounted, and take care not to bend the socket.
Note 2) Be noted for mounting that there are two types of lengths for the pilot valve
mounting screws.

Please contact SMC for detailed dimensions,


Made-to-Order for Valve specifications, and lead times.

Main Valve Fluororubber Specification


Fluororubber is used for rubber parts of the main valve to allow use in applications such as the following.
• When using a lubricant other than the recommended turbine oil, and there is a possibility of malfunction due to swelling of the
spool valve seals.

Applicable valve series SY3쏔 03 0, SY5쏔 03 0 (Only rubber seal type)

SY 35 0
3 0 1 X90
and Plug Assembly/
One-touch Fittings

Part No.

Entry is the same as standard products.


Manifold
Options

The specification and performance are the same as those of standard products.
Specific Product
Precautions

14
Type 50
Plug-in Metal Base
Side Ported D-sub Connector Flat Ribbon Cable PC Wiring

SY3000/5000
Type 51
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 50 F 1 05 D C6

Series Type Connector entry direction


3 SY3000 50 Side ported 1: Upward 2: Lateral
5 SY5000 51 Bottom ported
50R Side ported, External pilot
∗ External pilot is not available for
the bottom ported type.
Connector type
F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable
(25 pins) (26 pins) (20 pins)
Wiring type
Nil All double wiring Note 1)
S All single wiring Note 2)
Note 1) All double wiring: 2-position single, double, 3-position and 4-
position valves can be used on all manifold stations.
Note 2) All single wiring: Available only for the manifold which has 2-
PH: Flat ribbon cable J: PC wiring position single for all stations.
(10 pins) (20 pins) Note that 2-position double, 3- or 4-position valves cannot be used.
Note 3) Please contact SMC if a mixture of single wiring and double wiring
is required.

Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
Symbol Stations Note Symbol Stations Note Symbol Stations Note
How to Order Manifold Assembly 02 2 stations All 02 2 stations All 02 2 stations All
double double double
12 12 stations wiring 12 12 stations wiring 09 9 stations wiring
Example (SS5Y3-50F2-쏔) 02 2 stations All 02 2 stations All 02 2 stations All
2-position double (24 VDC)
2-position single (24 VDC) single single single
SY3200-5U1 (1 set)
SY3100-5U1 (3 sets) 12 12 stations wiring 12 12 stations wiring 12 12 stations wiring
3-position closed
center (24 VDC) PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins)
SY3300-5U1 (1 set) Symbol Stations Note Symbol Stations Note
02 2 stations All 02 2 stations All
double double
04 4 stations wiring 08 8 stations wiring
02 2 stations All 02 2 stations All
ide single single
Us 08 8 stations wiring 12 12 stations wiring
s
n
tio

∗ This also includes the number of blanking plate assembly.


ta
S

Manifold base 3
(5 stations) 2
1 P, E port entry Refer to the page on the right for .
SS5Y3-50F2-05D-C6 ide
Ds U U side Note 1)
D D side Note 1) Note 2) Thread type
SS5Y3-50F2-05D-C6 ··· 1 set (Type 50 5-station manifold base part no.) B Both sides Nil Rc
∗SY3100-5U1················· 3 sets (2-position single part no.) Note 1) Plugs are mounted on the opposite F G
∗SY3200-5U1················· 1 set (2-position double part no.) side of the selected ports. N NPT
∗SY3300-5U1················· 1 set (3-position closed center part no.) Note 2) Only D side is available for Type T NPTF
The asterisk denotes the symbol for assembly. 51 (Bottom ported).
Prefix it to the part nos. of the valve, etc.
Mounting
• The valve arrangement is numbered as the 1st station from the D side. Nil Direct mounting
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement be-
D DIN rail mounting (With DIN rail)
comes complicated, specify on a manifold specification sheet. D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations
Note) When mixing top ported configurations, select from page 30. Specify a longer rail than
In this case, use caution as there is also output on the A and B port on base side. the standard length.
Specify on a manifold specification sheet if plugs are required on the A and B D12 For 12 stations
port on base side. ∗ Only direct mounting is available for Type 51 (Bottom ported).
15
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Thread piping)
SY3000 SY5000

Flat Ribbon Cable


Symbol A, B port

D-sub Connector
M5 M5 x 0.8 쎲 —

PC Wiring
01 1/8 쎲 쎲
02 1/4 — 쎲

EX510
A, B port size (Metric) A, B port size (Inch)
Symbol A, B port SY3000 SY5000 Symbol A, B port SY3000 SY5000
C2 ø2 One-touch fitting 쎲 — N1 ø1/8" One-touch fitting 쎲 —

Terminal D-sub Connector Plug-in Connector


Connecting Base
C3 쎲 N3 쎲 쎲

Fixed
ø3.2 One-touch fitting — ø5/32" One-touch fitting
Fixed

C4 ø4 One-touch fitting 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲


C6 ø6 One-touch fitting 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲
C8 ø8 One-touch fitting — 쎲 KN1 ø1/8" One-touch fitting 쎲 — Type 50
(Side ported)
Type 51
(Bottom ported)
Replaceable
KC2 ø2 One-touch fitting 쎲 — Type 50 Type 51 KN3 ø5/32" One-touch fitting 쎲 쎲

Flat Ribbon Cable


(Side ported) (Bottom ported)
KC3 ø3.2 One-touch fitting 쎲 — KN7 ø1/4" One-touch fitting 쎲 쎲
Replaceable

Block Box PC Wiring


KC4 ø4 One-touch fitting 쎲 쎲 KN9 ø5/16" One-touch fitting — 쎲
KC6 ø6 One-touch fitting 쎲 쎲 M∗ Mixed sizes 쎲 쎲
KC8 ø8 One-touch fitting — 쎲 P, E port size (Thread piping) 1/8 1/4
M∗ Mixed sizes 쎲 쎲 ∗ When ports are mixed sizes, indicate the piping specifications on the
P, E port size (Thread piping) 1/8 1/4 manifold specification sheet.

Lead Wire
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Base mounted
Series
3 SY3000 Pilot valve option !0 Manual override
5 SY5000 Nil Standard (0.7 MPa) Nil: Non-locking D: Push-turn F: Slide locking
B Quick response type (0.7 MPa) push type locking slotted type
Type of actuation K∗ High pressure type (1.0 MPa) type
1 2-position single ∗ Only metal seal type is available for the high pressure type.
2 2-position double
3 3-position closed center Coil type
4 3-position exhaust center Nil Standard
5 3-position pressure center T With power saving circuit (Continuous duty type)
A∗ 4-position dual 3-port valve (N.C./N.C.) ∗ Be sure to select the power saving circuit type
B∗ 4-position dual 3-port valve (N.O./N.O.) when the valve is continuously energized for
C∗ long periods of time.
4-position dual 3-port valve (N.C./N.O.) Type of mounting screw
∗ Note the specified energizing time when power
∗ Only rubber seal type is available for the saving circuit is selected. Refer to page 154. Nil Round head combination screw
4-position dual 3-port valve. B Hexagon socket head cap screw
Rated voltage K Round head combination screw (Falling-out-prevention type)
Seal type 5 24 VDC H Hexagon socket head cap screw (Falling-out-prevention type)
0 Rubber seal 6 12 VDC ∗ For “K” and “H”, the valve body cover has a
1 Metal seal drop prevention construction to stop the
Light/surge voltage suppressor mounting screws from falling out when the
and Plug Assembly/
One-touch Fittings

Pilot type and common specification valve is removed for maintenance etc.
Nil Internal pilot Nil Without light/surge voltage suppressor (Non-polar) ∗ When ordering a valve individually, the base
Part No.

R External pilot R With surge voltage suppressor (Non-polar) gasket is not included. Since the base gasket
is attached to the manifold, please order the
U With light/surge voltage suppressor (Non-polar)
Back pressure check valve base gasket separately if it is needed for
Manifold

S
Options

With surge voltage suppressor (Positive common) maintenance service.


(Built-in valve type) Z With light/surge voltage suppressor (Positive common) Refer to page 47 for part numbers of the base
Nil None NS With surge voltage suppressor (Negative common) gasket and mounting screw.
H Built-in NZ With light/surge voltage suppressor (Negative common) ∗ “B” and “H” cannot be selected for the individual
SUP/EXH spacer assembly or double check spacer
Specific Product

∗ Only rubber seal type ∗ Only “Z” and “NZ” types are available for the
assembly with residual pressure release valve.
Precautions

∗ The built-in valve type back pressure check product with power saving circuit.
valve is not available for the 3-position type. Protective class
class (Mark: )
16
Series SY3000/5000

Dimensions: Type 50/D-sub Connector/Series SY3000


U M5
SS5Y3-50(R)F 12 - Stations D - KC
C쏔, N쏔 쏔(D)
쏔, KN쏔 B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
(Pitch)
Applicable connector: D-sub
JIS-X-5101
MIL-C-24308
equivalent ( ) DIN rail holding screw
(For DIN rail mounting)
45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
14 24.1 4(A) port side: Blue (For rubber seal)
Light/surge : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw (7.9) voltage
[Pilot EXH port] 2(B) port side: Yellow
(For DIN rail mounting) suppressor

DIN rail

(Connector entry
B A B A B A B A B A
upward direction)

92.7
89
5EA

PE

14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35

26.6
X

12 B 12 B 12 B 12 B 12 B
3EB

2 x M2.6 4 x ø4.5
8.6 L2 8
(For mounting) 4
)
Replaceable: 7.7

2 x 4-40 UNC
14.5 [For inch size thread] (L5) L1
22.1
Fixed: 4.1

6.1 (Station 1)---(Station n)


28

1/8

manual override)
(

(Slide locking
[1(P), 5(EA), 3(EB) port]
(68.7)

68.3
62.6
M5 x 0.8 (External pilot)
54.7

2B 2B
[External pilot port]
7.1

32
22.6
4A 4A

50RF 12 - Stations UD

(For DIN rail


mounting)
7.5
C2, C3: 5.4

11.8
3 C4, C6: 6.6
[Plug for external pilot] C2, C3: 42.4 (Pitch)
2B
C4, C6: 41.8 P = 10.5 One-touch fitting
4A [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
∗The above drawing shows when P, : ø6, ø1/4"
E port entry is D.
Note) These figures show the “SS5Y3-50F2-05B-C6”.

Port size M5 One-touch fitting (Replaceable)

2B 2B
7.1

7.1
32

32
22.6

22.6

4A 4A

M5 x 0.8
6.6 (Pitch)
[4(A), 2(B) port] P = 10.5
(Pitch) 48.4
41.8 P = 10.5
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

17
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 50/D-sub Connector/Series SY3000

Replacement
U
SS5Y3-50(R)F 21 - Stations D -01쏔(D)

Parts
B
D side U side
L3

Metal Base
5.3 L4

Plug-in
(DIN rail mounting hole pitch: 12.5)
Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent ) DIN rail holding screw 45.1
(Pitch)
P = 12.5 (
Push-turn locking slotted type:
)

Flat Ribbon Cable


Press, then rotate it.

D-sub Connector
(For DIN rail mounting) 14 24.1
M5 x 0.8 (External pilot) 4(A) port side: Blue (For rubber seal)

PC Wiring
Light/surge
DIN rail bracket mounting screw (7.9) : Gray (For metal seal)
[Pilot EXH port] voltage
(For DIN rail mounting) suppressor 2(B) port side: Yellow

EX510
DIN rail

(Connector entry B A B A B A B A B A

upward direction)

92.7

Terminal D-sub Connector Plug-in Connector


89
5EA

14 A 14 A 14 A 14 A 14 A
PE

Connecting Base
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35
X

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 2 x M2.6 4 x ø4.5 L2

Flat Ribbon Cable


4 8
2 x 4-40 UNC (For mounting)
14.5 [For inch size thread] (L5) L1

Block Box PC Wiring


22.1
(Station 1)------(Station n)
28 6.1

1/8

manual override)
(Slide locking
[1(P), 5(EA), 3(EB) port]

Lead Wire
(68.7)

68.3
62.6
M5 x 0.8 (External pilot)
54.7

2B 2B
[External pilot port]
7.1

32
22.6
4A 4A

Connector
Circular
(For DIN rail
mounting)
6.6
50RF 12 - Stations UD (Pitch) 7.5
11.8
1/8

EX120 EX126 EX260 EX250 EX600 EX500


41.8 P = 12.5
[4(A), 2(B) port]

3
[Plug for external pilot]
2B
Note) These figures show the “SS5Y3-50F2-05B-01”.
4A

∗The above drawing shows when P,


E port entry is D.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
Specific Product

L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
Precautions

L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

18
Series SY3000/5000

Dimensions: Type 50/D-sub Connector/Series SY5000


U 01
SS5Y5-50(R)F 12 - Stations D - KC
C쏔, N쏔 쏔(D)
쏔, KN쏔 B D side U side
L3
5.3 L4 Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent ) DIN rail holding screw
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 50 P = 16 Light/surge 4(A) port side: Blue (For rubber seal)
M5 x 0.8 (External pilot) 16 24.1 voltage : Gray (For metal seal)
[Pilot EXH port] DIN rail bracket mounting screw suppressor 2(B) port side: Yellow
(7.9)
(For DIN rail mounting)

DIN rail

(Connector entry B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
upward direction)

5.5
23.2

116.6
96.2

35
20
81.6

74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

30.2

8
X

12 B 12 B 12 B 12 B 12 B

4 x ø4.5
)

12.3 (For mounting) 5 L2


Replaceable: 8.5

2 x M2.6
18 (L5) L1
2 x 4-40 UNC
Fixed: 4.9

28 [For inch size thread]


6.1 (Station 1)----------- (Station n)
34
1/4

manual override)
(

(Slide locking
[1(P), 5(EA), 3(EB) port]
(74.7)

M5 x 0.8 (External pilot)

74.3
68.6
60.7

[External pilot port] 2B 2B

7.8

38
27.3
4A
50RF 12 - Stations UD
4A

10

(For DIN rail


mounting)
3 8.4 (Pitch)

14.3
[Plug for external pilot] 45.8 P = 16
2B
One-touch fitting
4A [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
∗The above drawing shows when P,
E port entry is D. Note) These figures show the “SS5Y5-50F2-05B-C8”.

Port size 01 One-touch fitting (Replaceable)

2B 2B
9.8
7.8

38

38
27.3

27.3

4A 4A

8.4 (Pitch)
(Pitch)
51.6 P = 16
45.8 P = 16
One-touch fitting
1/8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

19
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 50/D-sub Connector/Series SY5000

Replacement
U
SS5Y5-50(R)F 21 - Stations D -02쏔(D)

Parts
B

D side U side

Metal Base
L3

Plug-in
5.3 L4
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (DIN rail mounting hole pitch: 12.5) Manual override
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )

Flat Ribbon Cable


D-sub Connector
M5 x 0.8 (External pilot) Light/surge 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)

PC Wiring
[Pilot EXH port] DIN rail bracket mounting screw 16 24.1 voltage
(For DIN rail mounting) suppressor 2(B) port side: Yellow

EX510
DIN rail

(Connector entry B A B A B A B A B A
upward direction)
PE

14 A 14 A 14 A 14 A 14 A
5EA

106.2
5.5
23.2

Terminal D-sub Connector Plug-in Connector


116.6
96.2

35

Connecting Base
20
81.6

74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B 8

Flat Ribbon Cable


4 x ø4.5
12.3
(For mounting) 5 L2

Block Box PC Wiring


18 2 x M2.6 (L5) L1
28 2 x 4-40 UNC
[For inch size thread]
34 6.1 (Station 1) ------------- (Station n)

1/4

manual override)

Lead Wire
(Slide locking
[1(P), 5(EA), 3(EB) port]
(74.7)

74.3
M5 x 0.8 (External pilot)

68.6
60.7

2B 2B
[External pilot port]

9.8

Connector
38
27.3
4A 4A

Circular
10

(For DIN rail

EX120 EX126 EX260 EX250 EX600 EX500


mounting)
8.4 (Pitch) 1/4

14.3
[4(A), 2(B) port]
50RF 12 - Stations UD 45.8 P = 17.5

3
[Plug for external pilot]
2B

4A

Note) These figures show the “SS5Y5-50F2-05B-02”.

∗The above drawing shows when P,


E port entry is D.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
Specific Product

L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
Precautions

L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

20
Series SY3000/5000

Dimensions: Type 50/Flat Ribbon Cable/Series SY3000


P
U M5
SS5Y3-50(R) PG 1
PH 2 - Stations D - KC
C쏔, N쏔
쏔, KN쏔
쏔(D)
J B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
Applicable connector:
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) DIN rail holding screw 45.1
(Pitch)
P = 10.5
(Push-turn locking slotted type:
Press, then rotate it. )
Light/surge 4(A) port side: Blue (For rubber seal)
(For DIN rail mounting) 14 24.1
M5 x 0.8 (External pilot) Triangle mark : Gray (For metal seal)
voltage
[Pilot EXH port] DIN rail bracket mounting screw (9.9) suppressor 2(B) port side: Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A
(Connector entry

92.7
PE
5EA

89
14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79

5.5
upward direction)
64.4

35

56.9
21.8 16
1P
29.8

35

26.6
X

12 B 12 B 12 B 12 B 12 B
3EB

8.6 M5 x 0.8 (External pilot)


)

4 L2 8
Replaceable:7.7

[External pilot port]


14.5 4 x ø4.5 (L5) L1
1/8 (For mounting)
Fixed:4.1

22.1
[1(P), 5(EA), 3(EB) port] (Station 1)---(Station n)
28
18
(

manual override)
50PJG (20 pins) 50PH (10 pins)

(Slide locking
(80.6)

Triangle mark

68.3
62.6
56.7

Triangle mark
For PC wiring 2B 2B

7.1

32
22.6
4A 4A

(For DIN rail


mounting)
7.5
C2, C3: 5.4
5EA

5EA
PCW type
PE

PE

11.8
C4, C6: 6.6
1P

1P

C2, C3: 42.4 (Pitch)


X

X
3EB

3EB

C4, C6: 41.8 P = 10.5 One-touch fitting


[4(A), 2(B) port]
Applicable tube O.D.: ø2
Applicable connector: Applicable connector: : ø3.2, ø1/8"
20 pins MIL type with strain relief 10 pins MIL type with strain relief : ø4, ø5/32"
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) : ø6, ø1/4"

Note 1) These figures show the


Port size M5 One-touch fitting (Replaceable)
“SS5Y3-50P2-05B-C6”.
Note 2) Only connectors are different
for 50PG, 50PH and 50J.
L1 to L5 dimensions are the
same as 50P type.

2B 2B
50R PJ쏔 12 - Stations UD
7.1

7.1
32

32
22.6

22.6

4A 4A

3
6.6 M5 x 0.8 (Pitch) [Plug for external pilot]
[4(A), 2(B) port] 48.4 P = 10.5 2B
(Pitch)
41.8 P = 10.5 One-touch fitting 4A

[4(A), 2(B) port]


Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32" ∗The above drawing shows when P,
: ø6, ø1/4" E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

21
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 50/Flat Ribbon Cable/Series SY3000

Replacement
P
U
SS5Y3-50(R) PG 1
PH 2 - Stations D -01쏔(D)

Parts
J B
D side U side
L3

Metal Base
5.3 L4 Manual override

Plug-in
Applicable connector:
(DIN rail mounting hole pitch: 12.5)
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Pitch) (Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 45.1 P = 12.5 4(A) port side: Blue (For rubber seal)
Triangle mark

Flat Ribbon Cable


: Gray (For metal seal)

D-sub Connector
(For DIN rail mounting) 14 24.1 Light/surge
M5 x 0.8 (External pilot) 2(B) port side: Yellow
voltage

PC Wiring
[Pilot EXH port] DIN rail bracket mounting screw (9.9) suppressor
(For DIN rail mounting)

EX510
DIN rail

B A B A B A B A B A

92.7
89
5EA

PE

14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79

5.5
64.4

Terminal D-sub Connector Plug-in Connector


35

56.9

Connecting Base
21.8 16
1P
29.8

35
X

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 4 x ø4.5 4 L2 8
(For mounting)

Flat Ribbon Cable


14.5 (L5) L1

Block Box PC Wiring


22.1 (Connector entry
upward direction) (Station 1) ----- (Station n)
28
18
1/8

manual override)
(Slide locking
[1(P), 5(EA), 3(EB) port]
(80.6)

68.3
62.6

Lead Wire
56.7

M5 x 0.8 (External pilot) 2B 2B


[External pilot port]
7.1

32
22.6
4A 4A

Connector
Circular
(For DIN rail
6.6

mounting)
(Pitch)

7.5
50PJG (20 pins)

11.8
50PH (10 pins) 41.8 P = 12.5
1/8

EX120 EX126 EX260 EX250 EX600 EX500


Triangle mark
[4(A), 2(B) port]
For PC wiring Triangle mark

Note 1) These figures show the “SS5Y3-50P2-05B-01”.


Note 2) Only connectors are different for 50PG, 50PH and 50J.
L1 to L5 dimensions are the same as 50P type.
5EA

5EA
PCW type
PE

PE

50R PJ쏔 12 - Stations UD


1P

1P
X

X
3EB

3EB

3
Applicable connector: Applicable connector: [Plug for external pilot]
2B
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) 4A

∗The above drawing shows when P,


E port entry is D.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
Specific Product

L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
Precautions

L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

22
Series SY3000/5000

Dimensions: Type 50/Flat Ribbon Cable/Series SY5000


P
U 01
SS5Y5-50(R) PG 1
PH 2 - Stations D - KC
C쏔, N쏔
쏔, KN쏔
쏔(D) D side U side
J B L3
Applicable connector: 5.3 L4
Manual override
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5)
(Conforming to MIL-C-83503)
Triangle mark
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
Light/surge
M5 x 0.8 (External pilot) 16 24.1 : Gray (For metal seal)
DIN rail bracket mounting screw voltage
[Pilot EXH port] (9.9) suppressor 2(B) port side: Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A
PE

14 A 14 A 14 A 14 A 14 A
(Connector entry
5EA

106.2
5.5
23.2

116.6
96.2

35
20

upward direction)
81.6

74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

8
30.2
X

12 B 12 B 12 B 12 B 12 B

12.3
)

5 L2
Replaceable: 8.5

18 4 x ø4.5
(L5) L1
28 (For mounting)
Fixed: 4.9

34 M5 x 0.8 (External pilot)


[External pilot port] (Station 1) ----------- (Station n)
1/4 18
[1(P), 5(EA), 3(EB) port]
(

manual override)
50PJG (20 pins) 50PH (10 pins)

(Slide locking
(86.6)

Triangle mark

74.3
68.6
Triangle mark
62.7

2B 2B
For PC wiring

7.8

38
27.3
4A 4A

10

(For DIN rail


PCW type

8.4

mounting)
PE

PE
5EA

5EA

(Pitch)

14.3
45.8 P = 16
1P

1P

One-touch fitting
[4(A), 2(B) port]
3EB

3EB
X

Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
: ø8, ø5/16"

Applicable connector: Applicable connector: Note 1) These figures show the “SS5Y5-50P2-05B-C8”.
20 pins MIL type with strain relief 10 pins MIL type with strain relief Note 2) Only connectors are different for 50PG, 50PH and 50J.
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) L1 to L5 dimensions are the same as 50P type.

Port size 01 One-touch fitting (Replaceable) 50R PJ쏔 12 - Stations UD

3
[Plug for external pilot]
2B

2B
2B 4A
9.8

38
27.3
7.8

38
27.3

4A
4A

One-touch fitting ∗The above drawing shows when P,


(Pitch) [4(A), 2(B) port] E port entry is D.
8.4 (Pitch)
51.6 P = 16 Applicable tube O.D.: ø4, ø5/32"
45.8 P = 16 : ø6, ø1/4"
1/8 : ø8, ø5/16"
[4(A), 2(B) port]

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

23
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 50/Flat Ribbon Cable/Series SY5000

Replacement
P
U
SS5Y5-50(R) PG 1
PH 2 - Stations D -02쏔(D)

Parts
D side U side
J B L3

Metal Base
Applicable connector: 5.3 L4 Manual override
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5)
(
Push-turn locking slotted type:
)

Plug-in
(Conforming to MIL-C-83503) DIN rail holding screw (Pitch) Press, then rotate it.
Triangle mark (For DIN rail mounting) 50 P = 17.5 4(A) port side: Blue (For rubber seal)
M5 x 0.8 (External pilot) 16 24.1 Light/surge : Gray (For metal seal)
DIN rail bracket mounting screw
voltage suppressor 2(B) port side: Yellow

Flat Ribbon Cable


D-sub Connector
[Pilot EXH port] (For DIN rail mounting) (9.9)

PC Wiring
DIN rail

EX510
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE

(Connector entry
5EA

106.2
5.5
23.2

116.6
96.2

35
upward direction)
20
81.6

74.1
20
1P

Terminal D-sub Connector Plug-in Connector


24.6
20

Connecting Base
52.2

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B 8

12.3
5 L2
18

Flat Ribbon Cable


(L5) 4 x ø4.5
M5 x 0.8 (External pilot) L1
28 (For mounting)

Block Box PC Wiring


[External pilot port]
34
1/4 (Station 1) ------------- (Station n)
[1(P), 5(EA), 3(EB) port] 18

50PJG (20 pins) 50PH (10 pins)

manual override)
(Slide locking
(86.6)

Triangle mark
Triangle mark

Lead Wire
74.3
68.6
For PC wiring
62.7

2B 2B

9.8

38
27.3
4A 4A

Connector
Circular
10
PCW type
PE

PE
5EA

5EA

(For DIN rail


1/4

mounting)
8.4
(Pitch)

14.3
[4(A), 2(B) port]

EX120 EX126 EX260 EX250 EX600 EX500


45.8 P = 17.5
1P

1P
3EB

3EB
X

Note 1) These figures show the “SS5Y5-50P2-05B-02”.


Note 2) Only connectors are different for 50PG, 50PH and 50J.
Applicable connector: Applicable connector: L1 to L5 dimensions are the same as 50P type.
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

50R PJ쏔 12 - Stations UD

3
[Plug for external pilot]
2B

4A

∗The above drawing shows when P,


E port entry is D.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
Specific Product

L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
Precautions

L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

24
Series SY3000/5000

Dimensions: Type 51/D-sub Connector/Series SY3000


M5, 01
SS5Y3-51F 12- Stations D- KC
C쏔, N쏔 쏔
쏔, KN쏔
D side U side
Manual override

Light/surge voltage suppressor (


Push-turn locking slotted type:
Press, then rotate it. )
(Pitch) 4(A) port side: Blue (For rubber seal)
2 x M2.6
45.1 P = 10.5 : Gray (For metal seal)
2 x 4-40 UNC
14 24.1 2(B) port side: Yellow
[For inch size thread]
(7.9)
4 x ø4.5
(For mounting)

16
B A B A B A B A B A

92.7
89
14 A 14 A 14 A 14 A 14 A

64.4

35
12 B 12 B 12 B 12 B 12 B

21.8
(Max. 3) L1

6.1 (Station 1) ---(Station n)

manual override)
(Slide locking
(68.7)

68.3
62.6
54.7
Panel cut dimensions

32
(For 9 stations or more)

2 x ø4.5

(4.1)
(For 9 stations or more) (Pitch)
4

46.4 P = 10.5 One-touch fitting


40
17.8

23.6 [4(A), 2(B) port]


(For 9 stations or more) Applicable tube O.D.: ø2
4 x M4 x 0.7, thread depth 4
: ø3.2, ø1/8"
16.8

4 x ø4.5 (For mounting)


21.1
: ø4, ø5/32"
52.4
56.4
16

: ø6, ø1/4"
29.8

3EB 2B 2B
4 x M4 x 0.7 56.4
4 x ø4.5 4 4
1P

5EA 4A 4A

L3
16.8

Cut dimensions for panel mounting


L2 1/8
C2, C3, C4: 16
: 15

Refer to panel cut dimensions for details.


[1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3
(For 9 stations or more) L2
C6

Note) These figures show the “SS5Y3-


Port size M5 Port size 01 One-touch fitting (Replaceable)
51F2-05D-C6”.
32

32

) 32
C6: 12.8
N7: 16.6

(Pitch) (Pitch) (Pitch)


21.1
20.1

20.1

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


(
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


14

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

Port Size M5, C쏔, N쏔, KC쏔, KN쏔


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

25
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 51/D-sub Connector/Series SY5000

Replacement
01, 02
SS5Y5-51F 12- Stations D- KC
C쏔, N쏔 쏔 D side U side

Parts
쏔, KN쏔
Light/surge voltage suppressor Manual override
(Pitch)
(Push-turn locking slotted type:
)

Metal Base
50 P = 16 Press, then rotate it.
4(A) port side: Blue (For rubber seal)

Plug-in
2 x M2.6
16 24.1 : Gray (For metal seal)
2 x 4-40 UNC
2(B) port side: Yellow
[For inch size thread] (7.9)
4 x ø4.5

Flat Ribbon Cable


D-sub Connector
(For mounting)
B A B A B A B A B A

PC Wiring
106.2
14 A 14 A 14 A 14 A 14 A

116.6
81.6

30.2 20
52.2

EX510
12 B 12 B 12 B 12 B 12 B

(Max. 3) L1

Terminal D-sub Connector Plug-in Connector


6.1 (Station 1) ------ (Station n)

Connecting Base
manual override)
(Slide locking
(74.7)

74.3
68.6
60.7

38

Flat Ribbon Cable


Panel cut dimensions

Block Box PC Wiring


(Pitch)

(4.9)
2 x ø4.5 50 P = 16
25.2

(For 9 stations or more) 24 2 x M4 x 0.7 One-touch fitting


5

4 x M4 x 0.7, thread depth 5 (For 9 stations or more)


4 x ø4.5 [4(A), 2(B) port]
(For mounting)
Applicable tube O.D.: ø4, ø5/32"
61.6
71.6

40.2

3EB 2B 2B
: ø6, ø1/4"
20

: ø8, ø5/16"
20 20

Lead Wire
71.6
4 x M4 x 0.7 1P

4 x ø4.5
5EA 4A 4A
5 5
Cut dimensions for panel mounting
L3 1/4

Connector
C4, C6: 14.8
: 17.2

Refer to panel cut dimensions for details.


[1(P), 5(EA), 3(EB) port]

Circular
L2
L3
L2
C8

EX120 EX126 EX260 EX250 EX600 EX500


Port size 01 Port size 02 One-touch fitting (Replaceable) Note) These figures show the “SS5Y5-
51F2-05D-C8”.
38

38

38

(Pitch) (Pitch) (Pitch)


(15.5)

50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5

14.5
14.8

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
and Plug Assembly/
One-touch Fittings

Port Size 01, C쏔, N쏔, KC쏔, KN쏔


Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2
Manifold

74 90 106 122 138 154 170 186 202 218 234


Options

L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
Specific Product

L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
Precautions

L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

26
Series SY3000/5000

Dimensions: Type 51/Flat Ribbon Cable/Series SY3000


P M5, 01
SS5Y3-51 PG 1 C쏔, N쏔 쏔
PH 2 - Stations D- KC쏔, KN쏔
D side
Manual override
U side
J
Light/surge voltage suppressor
Applicable connector: (Pitch)
Push-turn locking slotted type:
Press, then rotate it. ( )
45.1 P = 10.5 4(A) port side: Blue (For rubber seal)
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) 14 24.1 : Gray (For metal seal)
2(B) port side: Yellow
(9.9)
51PJG (20 pins) 51PH (10 pins) 4 x ø4.5
(For mounting)
Triangle Triangle

16
B A B A B A B A B A

92.7
89
14 A 14 A 14 A 14 A 14 A

For PC wiring mark mark

64.4

35
12 B 12 B 12 B 12 B 12 B

21.8
(Connector entry
PCW type

upward direction)
(Max. 3) L1
(Station 1)---(Station n)

manual override)
Applicable connector: Applicable connector: 18

(Slide locking
20 pins MIL type with strain relief 10 pins MIL type with strain relief

(80.6)

68.3
62.6
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

56.7

32
Panel cut dimensions

(4.1)
(For 9 stations or more)

(Pitch)
46.4 P = 10.5 One-touch fitting
2 x ø4.5 23.6 [4(A), 2(B) port]
4

(For 9 stations or more) Applicable tube O.D.: ø2


4 x M4 x 0.7, thread depth 4
40 : ø3.2, ø1/8"

21.1
17.8

16.8

(For mounting)
(For 9 stations or more) : ø4, ø5/32"
4 x ø4.5 : ø6, ø1/4"
29.8

3EB 2B 2B
52.4
56.4
16

56.4
1P

4 x M4 x 0.7 5EA 4A 4A

4 x ø4.5
16.8

4 4 Cut dimensions for panel mounting


C2, C3, C4: 16
: 15
1/8 Refer to panel cut dimensions for details.
L3 [1(P), 5(EA), 3(EB) port] L3
L2 2 x M4 x 0.7
(For 9 stations or more) L2
C6

Port size M5 Port size 01 One-touch fitting (Replaceable) Note) These figures show the “SS5Y3-
51P2-05D-C6”.
32

32

32

(Pitch) (Pitch) (Pitch)


20.1

21.1

20.1
)

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


C6: 12.8
N7: 16.6
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17

1P 1P 1P
(

5EA 4A 5EA 4A 5EA 4A


14

One-touch fitting
M5 x 0.8 1/8
[4(A), 2(B) port]
[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

Port Size M5, C쏔, N쏔, KC쏔, KN쏔


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

27
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 51/Flat Ribbon Cable/Series SY5000

Replacement
P 01, 02
SS5Y5-51 PG 1 C쏔, N쏔 쏔
PH 2 - Stations D- KC
D side U side

Parts
쏔, KN쏔 Manual override
J
Applicable connector:
26 pins MIL type with strain relief
Light/surge voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )

Metal Base
(Pitch)
(Conforming to MIL-C-83503) 4(A) port side: Blue (For rubber seal)
50 P = 16

Plug-in
: Gray (For metal seal)
Triangle mark 16 24.1 2(B) port side: Yellow
(9.9) 4 x ø4.5
(For mounting)

Flat Ribbon Cable


D-sub Connector
B A B A B A B A B A

106.2
14 A 14 A 14 A 14 A 14 A

116.6

PC Wiring
51PJG (20 pins) 51PH (10 pins)

81.6

30.2 20
52.2
For PC wiring Triangle mark Triangle mark

EX510
12 B 12 B 12 B 12 B 12 B

(Max. 3) L1
(Connector entry
PCW type

upward direction)

Terminal D-sub Connector Plug-in Connector


(Station 1) ------ (Station n)

Connecting Base
18

manual override)
(Slide locking
(86.6)

74.3
68.6
62.7
Applicable connector: Applicable connector:

38
20 pins MIL type with strain relief 10 pins MIL type with strain relief

Flat Ribbon Cable


(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

Block Box PC Wiring


(Pitch)

(4.9)
50 P = 16
Panel cut dimensions 2 x M4 x 0.7
(For 9 stations or more)
24 One-touch fitting
2 x ø4.5 4 x M4 x 0.7, thread depth 5 [4(A), 2(B) port]
25.2

(For 9 stations or more) (For mounting) Applicable tube O.D.: ø4, ø5/32"
5

Lead Wire
4 x ø4.5 : ø6, ø1/4"
40.2

3EB 2B 2B

: ø8, ø5/16"
20 20

71.6
61.6
71.6
20

1P

4 x M4 x 0.7

Connector
5EA 4A 4A

Circular
4 x ø4.5 Cut dimensions for panel mounting
5 5 1/4
C4, C6: 14.8
L3 : 17.2 Refer to panel cut dimensions for details.
[1(P), 5(EA), 3(EB) port]
L2 L3

EX120 EX126 EX260 EX250 EX600 EX500


L2
C8

Port size 01 Port size 02 One-touch fitting (Replaceable)


Note) These figures show the “SS5Y5-
51P2-05D-C8”.
38

38

38

(Pitch) (Pitch) (Pitch)


50 P = 16 50 P = 17.5 50 P = 16
(15.5)
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5

14.5
14.8

5EA 4A 5EA 4A
5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
and Plug Assembly/
One-touch Fittings

Port Size 01, C쏔, N쏔, KC쏔, KN쏔


Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2
Manifold

74 90 106 122 138 154 170 186 202 218 234


Options

L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
Specific Product

L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
Precautions

L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

28
Plug-in Metal Base
D-sub Connector Flat Ribbon Cable PC Wiring

SY3000/5000
Type 52
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 52 F 1 05 D

Series Connector entry direction


3 SY3000 1: Upward 2: Lateral
5 SY5000

Type
52 Top ported
52R Top ported, External pilot

Connector type
F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable Wiring type
(25 pins) (26 pins) (20 pins) Nil All double wiring Note 1)
S All single wiring Note 2)
Note 1) All double wiring: 2-position single, double, 3-position and 4-
position valves can be used on all manifold stations.
Note 2) All single wiring: Available only for the manifold which has 2-
position single for all stations.
Note that 2-position double, 3- or 4-position valves cannot be used.
PH: Flat ribbon cable J: PC wiring Note 3) Please contact SMC if a mixture of single wiring and double wiring
(10 pins) (20 pins) is required.

Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
Symbol Stations Note Symbol Stations Note Symbol Stations Note
02 2 stations All 02 2 stations All 02 2 stations All
double double double
How to Order Manifold Assembly 12 12 stations wiring 12 12 stations wiring 09 9 stations wiring
02 2 stations All 02 2 stations All 02 2 stations All
Example (SS5Y3-52F2-쏔) single single single
2-position double (24 VDC) 12 12 stations wiring 12 12 stations wiring 12 12 stations wiring
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) SY3230-5U1-C6 (1 set) PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins)
3-position closed Symbol Stations Note Symbol Stations Note
center (24 VDC)
SY3330-5U1-C6 (1 set)
02 2 stations All 02 2 stations All
double double
04 4 stations wiring 08 8 stations wiring
02 2 stations All 02 2 stations All
single single
08 8 stations wiring 12 12 stations wiring
ide
Us ∗ This also includes the number of blanking plate assembly.
s
on
ati
St
P, E port entry Thread type
Manifold base 3
2 U U side Note) Nil Rc
(5 stations) 1
ide D D side Note) 00F G
SS5Y3-52F2-05D Ds
B Both sides 00N NPT
SS5Y3-52F2-05D ········· 1 set (Type 52 5-station manifold base part no.) Note) Plugs are mounted on the 00T NPTF
∗SY3130-5U1-C6 ··········· 3 sets (2-position single part no.) opposite side of the
∗SY3230-5U1-C6 ··········· 1 set (2-position double part no.) selected ports.
∗SY3330-5U1-C6 ··········· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly. Mounting
Prefix it to the part nos. of the valve, etc. Nil Direct mounting
D DIN rail mounting (With DIN rail)
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in D0 DIN rail mounting (Without DIN rail)
order from the 1st station as shown in the figure above. If the D3 For 3 stations
arrangement becomes complicated, specify on a manifold specification
Specify a longer rail than
sheet. the standard length.
D12 For 12 stations
29
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


Coil type
2 2-position double C2 ø2 One-touch fitting 쎲 —
Nil Standard

Block Box PC Wiring


3 3-position closed center C3 ø3.2 One-touch fitting 쎲 —
T With power saving circuit (Continuous duty type)
4 3-position exhaust center C4 ø4 One-touch fitting 쎲 쎲
∗ Be sure to select the power saving circuit type C6 ø6 One-touch fitting 쎲 쎲
5 3-position pressure center
when a valve is continuously energized for 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.)
long periods of time.
C8 ø8 One-touch fitting —
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Note the specified energizing time when power One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) saving circuit is selected. Refer to page 154. Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage
5 24 VDC
N7 ø1/4" One-touch fitting 쎲 쎲

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
6 12 VDC
Seal type
0 Rubber seal
Light/surge voltage suppressor

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
and common specification
Nil Without light/surge voltage suppressor (Non-polar)
Nil Rc
R With surge voltage suppressor (Non-polar)
F G
Pilot type U With light/surge voltage suppressor (Non-polar)
N NPT
Nil Internal pilot S With surge voltage suppressor (Positive common)
T NPTF
R External pilot Z With light/surge voltage suppressor (Positive common) ∗ Only Nil is available for M5.
NS With surge voltage suppressor (Negative common)
NZ With light/surge voltage suppressor (Negative common)
Back pressure check valve
(Built-in valve type) ∗ Only “Z” and “NZ” types are available for the Type of mounting screw
product with power saving circuit. Nil Round head combination screw
Nil None
H Built-in
B Hexagon socket head cap screw

∗ Only rubber seal type !0 Manual override K Round head combination screw (Falling-out-prevention type)
∗ The built-in valve type back pressure check
H Hexagon socket head cap screw (Falling-out-prevention type)
Nil: Non-locking D: Push-turn F: Slide locking
valve is not available for the 3-position type. push type locking slotted type ∗ For “K” and “H”, the valve body cover has a
type drop prevention construction to stop the
mounting screws from falling out when the
valve is removed for maintenance etc.
∗ When ordering a valve individually, the base
gasket is not included. Since the base gasket
is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
and Plug Assembly/

Refer to page 47 for part numbers of the base


One-touch Fittings

gasket and mounting screw.


∗ "B" and "H" cannot be selected for the individual
Part No.

SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
30
Series SY3000/5000

Dimensions: Type 52/D-sub Connector, Flat Ribbon Cable/Series SY3000


F
P 1 U
SS5Y3-52(R) PG
PH 2
- Stations D -쏔(D)
B
J
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (Pitch) Manual override

68.3
DIN rail holding screw
(For DIN rail mounting)
45.1
14 24.1
P = 10.5
(
Push-turn locking slotted type:
Press, then rotate it. )
Light/surge 4(A) port side: Blue (For rubber seal)
(Slide locking manual override) (7.9) voltage : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw suppressor 2(B) port side: Yellow
[Pilot EXH port] (For DIN rail mounting)

DIN rail

5.5
(Connector entry B A B A B A B A B A

upward direction)

92.7
4A 4A 4A 4A 4A
5EA

89
PE
16.8 17.2
15.9 16.2
79
64.4

56.9
21.8 16
1P

2 x M2.6

11
32.1
35
29.8

35
X

26.6
2B 2B 2B 2B 2B
2 x 4-40 UNC
3EB

[For inch size thread]


8.6 4 x ø4.5
One-touch fitting
8
14.5 (For mounting) 4 L2
M5 x 0.8 (External pilot) [4(A), 2(B) port]
22.1 (L5) L1 Applicable tube O.D.: ø2
[External pilot port]
28 : ø3.2, ø1/8"
1/8 M5 x 0.8
: ø4, ø5/32"
[1(P), 5(EA), 3(EB) port] [4(A), 2(B) port] : ø6, ø1/4"
(Station 1)---(Station n)
6.1
F
52R PJ쏔 12 - Stations U
D

)C6: 76.8
N7: 80.6
(68.7)
62.6
54.7

3
[Plug for external pilot]
(
32

(For DIN rail


7.5

mounting)
11.8

∗The above drawing shows when P,


E port entry is D.

Note) These figures show the “SS5Y3-52F2-05B”.

52P (26 pins) 52PJG (20 pins) 52PH (10 pins)


For PC wiring
Triangle mark Triangle mark Triangle mark
14 (9.9) 14 (9.9) 14 (9.9)

B A B A B A
4A 4A 4A
5EA

5EA

5EA
PE

PE

PE
PCW type
1P

1P

1P
X

2B 2B 2B
3EB

3EB

3EB

Applicable connector: Applicable connector: Applicable connector:


26 pins MIL type with strain relief 20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

31
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 52/D-sub Connector, Flat Ribbon Cable/Series SY5000

Replacement
F
P 1 U

Parts
SS5Y5-52(R) PG
PH 2
- Stations D -쏔(D) D side U side
B L3
J Manual override
L4

Metal Base
5.3
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent ) (DIN rail mounting hole pitch: 12.5) (
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
74.3 (Pitch) 4(A) port side: Blue (For rubber seal)
DIN rail holding screw 50 P = 16 Light/surge : Gray (For metal seal)
(Slide locking manual override)
68.6 (For DIN rail mounting) 16 24.1 voltage 2(B) port side: Yellow
M5 x 0.8 (External pilot) suppressor
DIN rail bracket mounting screw

Flat Ribbon Cable


(7.9)

D-sub Connector
[Pilot EXH port]

01 : 16.2
C쏔 : 14.5
(For DIN rail mounting)

PC Wiring
DIN rail
(Connector entry B A B A B A B A B A

EX510
4A 4A 4A 4A 4A
PE
5EA

upward direction)

106.2
5.5
23.2

116.6
96.2

20

35
81.6

74.1
20
1P
24.6
20

52.2

43.8

Terminal D-sub Connector Plug-in Connector


40.2

40.2
2 x M2.6

Connecting Base
3EB

30.2 8
X

2B 2B 2B 2B 2B
2 x 4-40 UNC
[For inch size thread]
12.3 1/8
18 M5 x 0.8 (External pilot) 4 x ø4.5 One-touch fitting
[4(A), 2(B) port]
[External pilot port] (For mounting) [4(A), 2(B) port]
28

Flat Ribbon Cable


1/4 5 L2 Applicable tube O.D.: ø4, ø5/32"
34 (L5) L1 : ø6, ø1/4"

Block Box PC Wiring


[1(P), 5(EA), 3(EB) port]
: ø8, ø5/16"

52P (26 pins) (Station 1)----------- (Station n)

6.1
Triangle mark 16 (9.9)

Lead Wire
(86.7)
(74.7)
72.3
60.7

B A

Connector
4A
PE
5EA

38

Circular
1P

EX120 EX126 EX260 EX250 EX600 EX500


3EB

(For DIN rail


X

10

mounting)
2B
14.3

Applicable connector: Note) These figures show the “SS5Y5-52F2-05B”.


26 pins MIL type with strain relief
(Conforming to MIL-C-83503)
F
52PJG (20 pins) 52PH (10 pins) 52R PJ쏔 12 - Stations UD
For PC wiring
16 (9.9) Triangle mark 16 (9.9)
Triangle mark

3
[Plug for external pilot]
B A B A
4A 4A
PE

PE
5EA

5EA
PCW type
1P

1P
3EB

3EB
X

2B 2B
∗The above drawing shows when P,
E port entry is D.
and Plug Assembly/
One-touch Fittings

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
Part No.

(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)


Manifold
Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
Specific Product

L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
Precautions

L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

32
Series SY3000/5000

Electrical Wiring Specifications Cable Assembly


015
D-sub connector
AXT100-DS25- 030
050 Lead wire color for
D-sub connector
1
14
2
cable assembly by
15
16
3 terminal number
4 Cable
17 Lead
5 Terminal Dot
18
6
0.3 mm2 x 25 cores wire
no. marking
19
7 O.D. ø1.4 color
20
21
8
Approx. ø10 1 Black None
9
22
23
10 2 Brown None
11
24
12
3 Red None
25 Seal (Length)
13
015 4 Orange None
Connector terminal no. 5 Yellow None

L
Lead wire color for Molded cover 6 Pink None
D-sub connector assembly 7 Blue None
2 x M2.6 x 0.45

44
015 8 Purple White
<All single wiring> <All double wiring> (AXT100-DS25- 030
050
)
9 Gray Black
Connector DB-25SF-N

8
Terminal Terminal Lead wire Dot made by Japan Aviation 10 White Black
no. no. Polarity color marking Electronics Industry, Ltd.
11 White Red

(2.4)
SOL.a SOL.a 55
Station 1 1 1 (–) (+) Black None 12 Yellow Red
SOL.a Station 1 SOL.b Socket side
Station 2 14 14 (–) (+) Yellow Black 13 Orange Red
SOL.a SOL.a 14 25
Station 3 2 2 (–) (+) Brown None 14 Yellow Black
SOL.a Station 2 SOL.b 16 Terminal no.
Station 4 15 15 (–) (+) Pink Black 15 Pink Black
SOL.a SOL.a
Station 5 3 3 (–) (+) Red None 16 Blue White
SOL.a Station 3 SOL.b 1 13
Station 6 16 16 (–) (+) Blue White 47.04 17 Purple None
Station 7 SOL.a SOL.a 18 Gray None
4 4 (–) (+) Orange None
SOL.a Station 4 SOL.b 19 Orange Black
Station 8 17 17 (–) (+) Purple None
Station 9 SOL.a 5 SOL.a 5 20 Red White
(–) (+) Yellow None
SOL.a Station 5 SOL.b 21 Brown White
Station 10 18 18 (–) (+) Gray None
Station 11 SOL.a
6 SOL.a 6
D-sub connector cable assembly 22 Pink Red
(–) (+) Pink None
SOL.a Station 6 SOL.b Cable 23 Gray Red
Station 12 19 19 (–) (+) Orange Black Assembly part no. Note
SOL.a length (L) 24 Black White
7 7 (–) (+) Blue None
Station 7 SOL.b 1.5 m AXT100-DS25-015 25 White None
20 20 (–) (+) Red White Cable
SOL.a 3m AXT100-DS25-030
8 8 (–) (+) Purple White 0.3 mm2 x 25 cores
Station 8 SOL.b 5m AXT100-DS25-050
21 21 (–) (+) Brown White
SOL.a ∗ When using a standard commercial
9 9 (–) (+) Gray Black connector, use a 25-pin type female
Station 9 SOL.b
22 22 (–) (+) Pink Red connector conforming to MIL-C-24308.
10 SOL.a 10 ∗ Cannot be used for movable wiring.
(–) (+) White Black
Station 10 SOL.b ∗ Lengths other than the above are also
23 23 (–) (+) Gray Red
SOL.a
available. Please contact SMC for details.
11 11 (–) (+) White Red
Station 11 SOL.b
24 24 (–) (+) Black White Electrical characteristics Connector Manufacturers’ Example
12 SOL.a 12
Station 12 (–) (+) Yellow Red Item Property • Fujitsu, Ltd.
SOL.b
25 25 (–) (+) White None Conductor resistance • Japan Aviation Electronics Industry, Ltd.
Ω/km, 20°C 65 or less
COM. 13 COM. 13 (+) (–) Orange Red
• J.S.T. Mfg. Co., Ltd.
Voltage limit
• Hirose Electric Co., Ltd.
Positive Negative V, 1 minute, AC 1000
common common
Insulation resistance
MΩ/km, 20°C 5 or more
Note) When using a valve with no polarity, either positive common or
negative common can be used. Note) The minimum bending
radius of the D-sub
connector cable is 20 mm.

33
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Replacement
Electrical Wiring Specifications Cable Assembly

Parts
10 1
Flat ribbon cable connector AXT100-FC 20 -2
26 3

Metal Base
26 25
24 23
6 Terminal no. 28AWG
Red

Plug-in
22 21
20 19

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
18 17
16 15
14 13

Flat Ribbon Cable


D-sub Connector
12 11

PC Wiring
10 9

26

25
8 7
6 5 Connector terminal no. (15.6)

EX510
4 3 L
2 1
Triangle mark indicator position Flat ribbon cable connector assembly
Cable Assembly part no.
P: Flat ribbon cable (26 pins) length (L) 26 pins 20 pins 10 pins

Terminal D-sub Connector Plug-in Connector


Connecting Base
<All single wiring> <All double wiring> 1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
Terminal no. Terminal no. Polarity 3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2
SOL.a SOL.a (–) 5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3
Station 1 1 1 (+)
SOL.a Station 1 SOL.b
Station 2 2 2 (–) (+) ∗ When using a standard commercial connector, use a 26-pin, 20-pin or
SOL.a SOL.a (–) (+)
Station 3 3 3 10-pin type connector conforming to MIL-C-83503 with strain relief.
SOL.a Station 2 SOL.b

Flat Ribbon Cable


Station 4 4 4 (–) (+) ∗ Cannot be used for movable wiring.
SOL.a SOL.a (–) (+)
Station 5 5 5 ∗ Lengths other than the above are also available. Please contact SMC for
Station 3

Block Box PC Wiring


SOL.a SOL.b
Station 6 6 6 (–) (+) details.
SOL.a 7 SOL.a 7 (–) (+)
Station 7
SOL.a 8
Station 4 SOL.b 8 (–) (+)
Connector Manufacturers’ Example
Station 8
SOL.a 9 SOL.a 9 (–) (+)
Station 9 • Hirose Electric Co., Ltd. • Japan Aviation Electronics Industry, Ltd.
SOL.a Station 5 SOL.b
Station 10 10 10 (–) (+)
SOL.a SOL.a • Sumitomo 3M Limited • J.S.T. Mfg. Co., Ltd.
Station 11 11 11 (–) (+)
SOL.a Station 6 SOL.b • Fujitsu, Ltd. • Oki Electric Cable Co., Ltd.
Station 12 12 12 (–) (+)

Lead Wire
13 SOL.a 13 (–) (+)
Station 7 SOL.b
14 14 (–) (+)
SOL.a PH: Flat ribbon cable (10 pins)
15 15 (–) (+)
Station 8 SOL.b
16 16 (–) (+) <All single wiring> <All double wiring>

Connector
17 SOL.a 17 (–) (+) Terminal no. Terminal no. Polarity

Circular
Station 9 SOL.b
18 18 (–) (+) SOL.a SOL.a
SOL.a Station 1 1 1 (–) (+)
19 19 (–) (+) SOL.a Station 1 SOL.b
Station 10 SOL.b Station 2 2 2 (–) (+)
20 20 (–) (+) SOL.a SOL.a
Station 3 3 3 (–) (+)

EX120 EX126 EX260 EX250 EX600 EX500


21 SOL.a 21 (–) (+) Station 2
Station 4 SOL.a SOL.b
Station 11 SOL.b 4 4 (–) (+)
22 22 (–) (+) SOL.a SOL.a
SOL.a Station 5 5 5 (–) (+)
23 23 (–) (+) SOL.a Station 3 SOL.b
Station 12 SOL.b Station 6 6 6 (–) (+)
24 24 (–) (+) SOL.a SOL.a
Station 7 7 7 (–) (+)
COM. COM. SOL.a Station 4 SOL.b
25 25 Station 8 8 8 (–) (+)
COM. 26 COM. 26 (+) (–) COM. COM.
9 9
COM. 10 COM. 10
Positive Negative (+) (–)
common common
Positive Negative
common common
PG: Flat ribbon cable (20 pins)
<All single wiring> <All double wiring> J: Flat ribbon cable (20 pins) PC wiring
Terminal no. Terminal no. Polarity
SOL.a SOL.a <All single wiring> <All double wiring>
Station 1 1 1 (–) (+) Terminal Polarity Terminal Polarity
SOL.a Station 1 SOL.b
Station 2 2 2 (–) (+) no. no.
SOL.a SOL.a SOL.a (–) (+) SOL.a (–) (+)
Station 3 3 3 (–) (+) Station 1 20 20
SOL.a Station 2 SOL.b SOL.a Station 1 SOL.b
Station 4 4 4 (–) (+) Station 2 18 (–) (+) 18 (–) (+)
SOL.a SOL.a SOL.a (–) (+) SOL.a (–) (+)
Station 5 5 5 (–) (+) Station 3 16 16
SOL.a Station 3 SOL.b SOL.a Station 2 SOL.b
Station 6 6 6 (–) (+) Station 4 14 (–) (+) 14 (–) (+)
SOL.a SOL.a SOL.a (–) (+) SOL.a (–) (+)
Station 7 7 7 (–) (+) Station 5 12 12
SOL.a Station 4 SOL.b SOL.a Station 3 SOL.b
Station 8 8 8 (–) (+) Station 6 10 (–) (+) 10 (–) (+)
SOL.a SOL.a (–) (+) SOL.a 8 (–) (+) SOL.a 8 (–) (+)
Station 9 9 9 Station 7
SOL.a Station 5 SOL.b SOL.a Station 4 SOL.b
Station 10 10 10 (–) (+) Station 8 6 (–) (+) 6 (–) (+)
SOL.a 11 SOL.a 11 (–) (+) SOL.a 19 (–) (+) SOL.a 19 (–) (+)
Station 11 Station 9 Station 5
SOL.a Station 6 SOL.b SOL.a (–) SOL.b (–)
Station 12 12 12 (–) (+) Station 10 17 (+) 17 (+)
SOL.a SOL.a (–) SOL.a
and Plug Assembly/

13 13 (–) (+) Station 11 15 (+) 15 (–) (+)


One-touch Fittings

Station 7 SOL.b SOL.a Station 6 SOL.b


14 14 (–) (+) Station 12 13 (–) (+) 13 (–) (+)
15 SOL.a (–) (+) 11 SOL.a 11 (–) (+)
15
Part No.

Station 8 SOL.b Station 7 SOL.b


16 16 (–) (+) 9 9 (–) (+)
17 SOL.a 17 (–) (+) 7 SOL.a 7 (–) (+)
Station 9 SOL.b Station 8 SOL.b (–)
Manifold

18 18 (–) (+) 5 5 (+)


Options

COM. COM. 4 4
19 19
COM. COM. 3 3
20 20 (+) (–)
COM. 2 (+) (–) COM. 2
Positive Negative
COM. 1 (+) (–) COM. 1 (+) (–)
common common
Specific Product

Positive Negative Positive Negative


Precautions

Note) When using a valve with no polarity, either positive common or common common common common
negative common can be used.

34
Plug-in Metal Base
Type 50
Side Ported EX510

SY3000/5000
Type 51
Bottom Ported
Series
How to Order Manifold

SS5Y 3 50 S5 05 D C6

Series Type P, E port entry Thread type


3 SY3000 50 Side ported U U side Note 1) Nil Rc
5 SY5000 51 Bottom ported D D side Note 1) Note 2) F G
50R Side ported, External pilot B Both sides N NPT
SI unit output polarity
∗ External pilot is not available for Note 1) Plugs are mounted on the opposite side of T NPTF
Nil Positive common
the bottom ported type. the selected ports.
N Negative common Note 2) Only D side is available for Type 51 (Bottom ported).
Wiring type A, B port size (Thread piping)
Nil All double wiring Note 1) Symbol A, B port SY3000 SY5000
S All single wiring Note 2) M5 M5 x 0.8 쎲 —
Note 1) All double wiring: 2-position single, double, 3-position and 4-position 01 1/8 쎲 쎲
valves can be used on all manifold stations. 02 1/4 — 쎲
Note 2) All single wiring: Available only for the manifold which has 2-position
single for all stations. A, B port size (Metric)
Note that 2-position double, 3- or 4-position valves cannot be used. Symbol A, B port SY3000 SY5000
Note 3) Please contact SMC if a mixture of single wiring and double wiring is required. C2 ø2 One-touch fitting 쎲 —
Valve stations C3 ø3.2 One-touch fitting 쎲 —
Fixed

Symbol Stations Note Symbol Stations Note C4 ø4 One-touch fitting 쎲 쎲


02 2 stations 02 2 stations 쎲 쎲
All double All single C6 ø6 One-touch fitting

08 8 stations
wiring
12 12 stations
wiring C8 ø8 One-touch fitting — 쎲
∗ This also includes the number of blanking plate assembly.
KC2 ø2 One-touch fitting 쎲 — Type 50 Type 51
(Side ported) (Bottom ported)
KC3 쎲
Replaceable

ø3.2 One-touch fitting —


How to Order Manifold Assembly KC4 ø4 One-touch fitting 쎲 쎲
KC6 ø6 One-touch fitting 쎲 쎲
Example (SS5Y3-50S5-쏔) KC8 ø8 One-touch fitting — 쎲
2-position single (24 VDC) 2-position double (24 VDC) M∗ Mixed sizes 쎲 쎲
SY3100-5U1 (3 sets) SY3200-5U1 (1 set)
P, E port size (Thread piping) 1/8 1/4
3-position closed
center (24 VDC) A, B port size (Inch)
SY3300-5U1 (1 set)
Symbol A, B port SY3000 SY5000
N1 ø1/8" One-touch fitting 쎲 —
N3 쎲 쎲
Fixed

ø5/32" One-touch fitting


N7 ø1/4" One-touch fitting 쎲 쎲
N9 ø5/16" One-touch fitting — 쎲
e
Us
id KN1 ø1/8" One-touch fitting 쎲 — Type 50 Type 51
Replaceable

(Side ported) (Bottom ported)


KN3 ø5/32" One-touch fitting 쎲 쎲
s
n
tio
ta

KN7 쎲 쎲
S

ø1/4" One-touch fitting


3
Manifold base 2 KN9 ø5/16" One-touch fitting — 쎲
1
(5 stations) ide M∗ Mixed sizes 쎲 쎲
SS5Y3-50S5-05D-C6 Ds
P, E port size (Thread piping) 1/8 1/4
SS5Y3-50S5-05D-C6 ··· 1 set (Type 50 5-station manifold base part no.)
∗ When ports are mixed sizes, indicate the piping specifications on the
∗SY3100-5U1 ················· 3 sets (2-position single part no.)
manifold specification sheet.
∗SY3200-5U1 ················· 1 set (2-position double part no.)
∗SY3300-5U1 ················· 1 set (3-position closed center part no.) Mounting
The asterisk denotes the symbol for assembly. Nil Direct mounting
Prefix it to the part nos. of the valve, etc. D DIN rail mounting (With DIN rail)
• The valve arrangement is numbered as the 1st station from the D side. D0DIN rail mounting (Without DIN rail)
• Under the manifold part number, state the valves to be mounted in order D3
For 3 stations ∗ Only direct mounting is
Specify a longer rail than
from the 1st station as shown in the figure above. If the arrangement be- available for Type 51
the standard length.
comes complicated, specify on a manifold specification sheet. D12 For 12 stations (Bottom ported).
Note) When mixing top ported configurations, select from page 44.
Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
In this case, use caution as there is also output on the A and B port on base side.
Electric Products (CAT.E150) for details on the EX510 Gateway-
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
type Serial Transmission System.

35
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 0 0 5 1

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Base mounted

Series Back pressure check valve Light/surge voltage suppressor


(Built-in valve type) and common specification
3 SY3000

Terminal D-sub Connector Plug-in Connector


Nil None R With surge voltage suppressor (Non-polar)

Connecting Base
5 SY5000
H Built-in U With light/surge voltage suppressor (Non-polar)
∗ Only rubber seal type S With surge voltage suppressor (Positive common)
∗ The built-in valve type back pressure check Z With light/surge voltage suppressor (Positive common)
valve is not available for the 3-position type. NS With surge voltage suppressor (Negative common)
Type of actuation
NZ Without light/surge voltage suppressor (Negative common)

Flat Ribbon Cable


1 2-position single
∗ Only “Z” and “NZ” types are available for the

Block Box PC Wiring


2 2-position double
Pilot valve option product with power saving circuit. Select a
3 3-position closed center valve from R, U, S or Z when the SI unit output
4 3-position exhaust center Nil Standard (0.7 MPa)
polarity is Nil (Positive common).
5 3-position pressure center B Quick response type (0.7 MPa) Select a valve from R, U, NS or NZ when the
A∗ 4-position dual 3-port valve (N.C./N.C.) K∗ High pressure type (1.0 MPa) SI unit output polarity is N (Negative common).
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Only metal seal type is available for the high
pressure type.

Lead Wire
C∗ 4-position dual 3-port valve (N.C./N.O.)
∗ Only rubber seal type is available for the !0 Manual override
4-position dual 3-port valve. Coil type Nil: Non-locking D: Push-turn F: Slide locking
Nil Standard push type locking slotted type

Connector
T

Circular
With power saving circuit (Continuous duty type) type
∗ Be sure to select the power saving circuit type
Seal type when the valve is continuously energized for
long periods of time.

EX120 EX126 EX260 EX250 EX600 EX500


0 Rubber seal
∗ Note the specified energizing time when power
1 Metal seal saving circuit is selected. Refer to page 154.

Rated voltage
Pilot type 5 24 VDC
Nil Internal pilot Type of mounting screw
R External pilot Nil Round head combination screw
B Hexagon socket head cap screw
K Round head combination screw (Falling-out-prevention type)
H Hexagon socket head cap screw (Falling-out-prevention type)
∗ For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
mounting screws from falling out when the
valve is removed for maintenance etc.
∗ When ordering a valve individually, the base
gasket is not included. Since the base gasket
is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 47 for part numbers of the base
gasket and mounting screw.
∗ “B” and “H” cannot be selected for the individual
and Plug Assembly/
One-touch Fittings

SUP/EXH spacer assembly or double check spacer


assembly with residual pressure release valve.
Part No.
Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
36
Series SY3000/5000

Dimensions: Type 50/EX510/Series SY3000


U M5
SS5Y3-50(R)S5쏔- Stations D - KC
C쏔, N쏔 쏔(D)
쏔, KN쏔 B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
(Pitch)

M5 x 0.8 (External pilot) DIN rail holding screw


45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
18.5 19.6 Light/surge 4(A) port side: Blue (For rubber seal)
[Pilot EXH port] (For DIN rail mounting)
voltage : Gray (For metal seal)
DIN rail bracket mounting screw suppressor 2(B) port side: Yellow
(For DIN rail mounting)
DIN rail

B A B A B A B A B A

92.7
5EA

14 A 14 A 14 A 14 A 14 A

89
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 4 x ø4.5 SI unit 8


)Replaceable: 7.7

14.5 (For mounting)


4 L2
22.1 (L5) L1
Fixed: 4.1

28 M5 x 0.8 (External pilot)


[External pilot port]
1/8 (Station 1)---(Station n)
(

[1(P), 5(EA), 3(EB) port]

manual override)
(Slide locking
50RS5쏔- Stations UD

68.3
65.6

62.6
2B 2B

7.1

32
22.6
4A 4A

3
[Plug for external pilot]

(For DIN rail


2B

mounting)
C2, C3: 5.4 One-touch fitting

7.5
11.8
4A C4, C6: 6.6 [4(A), 2(B) port]
Applicable tube O.D.: ø2
C2, C3: 42.4 (Pitch) : ø3.2, ø1/8"
C4, C6: 41.8 P = 10.5 : ø4, ø5/32"
∗The above drawing shows when P, : ø6, ø1/4"
E port entry is D.
Note) These figures show the “SS5Y3-50S5-05B-C6”.

Port size M5 One-touch fitting (Replaceable)

2B 2B
7.1
7.1

32

32
22.6

22.6

4A 4A

One-touch fitting
M5 x 0.8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø2
6.6 (Pitch)
(Pitch) : ø3.2, ø1/8"
41.8 P = 10.5 : ø4, ø5/32"
48.4 P = 10.5
: ø6, ø1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

37
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 50/EX510/Series SY3000

Replacement
U
SS5Y3-50(R)S5쏔- Stations D -01쏔(D)

Parts
B
D side U side
L3

Metal Base
5.3 L4

Plug-in
(DIN rail mounting hole pitch: 12.5) Manual override
M5 x 0.8 (External pilot)
[Pilot EXH port]
DIN rail holding screw 45.1
(Pitch)
P = 12.5 (Push-turn locking slotted type:
Press, then rotate it. )
18.5 19.6 4(A) port side: Blue (For rubber seal)

Flat Ribbon Cable


(For DIN rail mounting)

D-sub Connector
Light/surge voltage : Gray (For metal seal)
suppressor 2(B) port side: Yellow

PC Wiring
DIN rail bracket mounting screw
(For DIN rail mounting)

EX510
DIN rail
B A B A B A B A B A

92.7
5EA

14 A 14 A 14 A 14 A 14 A

89
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P

Terminal D-sub Connector Plug-in Connector


Connecting Base
29.8

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 4 x ø4.5 SI unit 8


14.5 (For mounting) 4 L2

Flat Ribbon Cable


22.1 M5 x 0.8 (External pilot) (L5) L1

Block Box PC Wiring


28 [External pilot port]
1/8
[1(P), 5(EA), 3(EB) port]
(Station 1)------ (Station n)

manual override)
(Slide locking

Lead Wire
68.3
65.6

62.6
50RS5쏔- Stations UD 2B 2B 7.1

32
22.6

Connector
4A 4A

Circular
3

(For DIN rail


6.6

mounting)
[Plug for external pilot] (Pitch) 1/8
7.5

EX120 EX126 EX260 EX250 EX600 EX500


2B 41.8 P = 12.5 [4(A), 2(B) port] 11.8

4A

∗The above drawing shows when P,


E port entry is D. Note) These figures show the “SS5Y3-50S5-05B-01”.

and Plug Assembly/


One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
Specific Product

L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
Precautions

L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

38
Series SY3000/5000

Dimensions: Type 50/EX510/Series SY5000


U 01
SS5Y5-50(R)S5쏔- Stations D - KC
C쏔, N쏔 쏔(D)
쏔, KN쏔 B
D side U side
L3
M5 x 0.8 (External pilot) 5.3 L4
Manual override
[Pilot EXH port] (DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
DIN rail bracket mounting screw 20.5 19.6 Light/surge voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor 2(B) port side: Yellow

DIN rail
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
35
96.2

20
81.6

74.1
20
1P
24.6
20

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B

4 x ø4.5
)
Replaceable: 8.5

12.3 SI unit
(For mounting)
18 5 L2
Fixed: 4.9

28 (L5) L1
34 M5 x 0.8 (External pilot)
[External pilot port]
(

1/4
[1(P), 5(EA), 3(EB) port]
(Station 1)----------- (Station n)

50RS5쏔- Stations UD

manual override)
(Slide locking
74.3
71.6

68.6
3 2B 2B
7.8

[Plug for external pilot] 38


27.3

4A 4A
2B

4A
(For DIN rail
8.4
10

(Pitch) One-touch fitting mounting)


14.3

45.8 P = 16 [4(A), 2(B) port]


∗The above drawing shows when P, Applicable tube O.D.: ø4, ø5/32"
E port entry is D. : ø6, ø1/4"
: ø8, ø5/16"

Note) These figures show the “SS5Y5-50S5-05B-C8”.

Port size 01 One-touch fitting (Replaceable)

2B 2B
7.8

9.8
38

38
27.3

27.3

4A 4A

One-touch fitting
8.4 1/8 [4(A), 2(B) port]
(Pitch) Applicable tube O.D.: ø4, ø5/32"
[4(A), 2(B) port]
45.8 P = 16
(Pitch) : ø6, ø1/4"
51.6 P = 16 : ø8, ø5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

39
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 50/EX510/Series SY5000

Replacement
U
SS5Y5-50(R)S5쏔- Stations D -02쏔(D)

Parts
B

Metal Base
D side U side

Plug-in
L3
M5 x 0.8 (External pilot)
5.3 L4
[Pilot EXH port] Manual override
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
(
Push-turn locking slotted type:
)

Flat Ribbon Cable


(Pitch)

D-sub Connector
(For DIN rail mounting) Press, then rotate it.
50 P = 17.5

PC Wiring
DIN rail bracket mounting screw 4(A) port side: Blue (For rubber seal)
20.5 19.6 Light/surge voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor
2(B) port side: Yellow

EX510
DIN rail

B A B A B A B A B A

Terminal D-sub Connector Plug-in Connector


Connecting Base
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
35
96.2

20
81.6

74.1
20
1P
24.6
20

43.8
40.2

3EB

8
30.2
X

12 B 12 B 12 B 12 B 12 B

Flat Ribbon Cable


Block Box PC Wiring
12.3 4 x ø4.5 SI unit
(For mounting)
18 5 L2
28 (L5) L1
34 M5 x 0.8 (External pilot)
[External pilot port]

Lead Wire
1/4
[1(P), 5(EA), 3(EB) port] (Station 1) ------------- (Station n)

manual override)

Connector
(Slide locking

Circular
50RS5쏔- Stations UD

74.3
71.6

68.6
2B 2B

EX120 EX126 EX260 EX250 EX600 EX500


9.8

38
27.3

4A 4A
3
[Plug for external pilot]
2B
(For DIN rail
10

8.4
mounting)
(Pitch) 1/4
4A
14.3

45.8 P = 17.5 [4(A), 2(B) port]

∗The above drawing shows when P,


E port entry is D. Note) These figures show the “SS5Y5-50S5-05B-02”.

and Plug Assembly/


One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
Specific Product

L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
Precautions

L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

40
Series SY3000/5000

Dimensions: Type 51/EX510/Series SY3000


M5, 01
SS5Y3-51S5쏔- Stations D- KC
C쏔, N쏔
쏔, KN쏔
쏔 D side (Pitch) U side
45.1 P = 10.5 Manual override
18.5 19.6 Light/surge voltage
suppressor (Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side: Yellow

B A B A B A B A B A

92.7
89
14 A 14 A 14 A 14 A 14 A
64.4

56.9
21.8 16
12 B 12 B 12 B 12 B 12 B

4 x ø4.5 SI unit
(For mounting)
(Max. 3) L1
(Station 1)---(Station n)

manual override)
(Slide locking
68.3
Panel cut dimensions
65.6

62.6
16 17.8 (For 9 stations or more)

32
2 x ø4.5
4

(For 9 stations or more)

(4.1)
40 (Pitch)
One-touch fitting
(For 9 stations or more) 4 x M4 x 0.7, thread depth 4 46.4 P = 10.5
[4(A), 2(B) port]
(For mounting) 23.6 Applicable tube O.D.: ø2
4 x ø4.5
: ø3.2, ø1/8"

21.1
29.8

3EB 2B 2B
52.4

: ø4, ø5/32"
56.4

16.8 16.8

: ø6, ø1/4"

56.4
1P
4 x M4 x 0.7
4 x ø4.5 5EA 4A 4A
4 4
Cut dimensions for panel mounting
L3
C2, C3, C4 : 16
: 15
1/8
Refer to panel cut dimensions for details.
L2 [1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3
C6

(For 9 stations or more) L2 Note) These figures show the “SS5Y3-


51S5-05D-C6”.

Port size M5 Port size 01 One-touch fitting (Replaceable)


32

32

) 32

(Pitch) (Pitch) (Pitch)


C6: 12.8
N7: 16.6

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


17 20.1

17 20.1
14 21.1
29.8

29.8

29.8
(

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

Port Size M5, C쏔, N쏔, KC쏔, KN쏔 Port Size 01


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5 L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 68.5 73.8 79 84.3 L3 — — — — — — — 77.8 84 90.3 96.5

41
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 51/EX510/Series SY5000

Replacement
01, 02
C쏔, N쏔 쏔
SS5Y5-51S5- Stations D - KC D side (Pitch) U side

Parts
쏔, KN쏔 50 P = 16
20.5 19.6 Light/surge Manual override
voltage suppressor
(
Push-turn locking slotted type:
)

Metal Base
Press, then rotate it.

Plug-in
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
B A B A B A B A B A 2(B) port side: Yellow
14 A 14 A 14 A 14 A 14 A

106.2
116.6

Flat Ribbon Cable


D-sub Connector
81.6

74.1
20

PC Wiring
30.2
12 B 12 B 12 B 12 B 12 B

EX510
4 x ø4.5
SI unit
(For mounting)
(Max. 3) L1

Terminal D-sub Connector Plug-in Connector


(Station 1) ----------- (Station n)

Connecting Base
manual override)
(Slide locking
74.3
71.6

68.6

Flat Ribbon Cable


38
Panel cut dimensions

Block Box PC Wiring


2 x ø4.5
(For 9 stations or more) 4 x M4 x 0.7, thread depth 5
5

(4.9)
(Pitch) 2 x M4 x 0.7
4 x ø4.5 (For mounting) 50 P = 16
20 25.2

(For 9 stations or more)


24
One-touch fitting
61.6
71.6

Lead Wire
[4(A), 2(B) port]
3EB 2B 2B
40.2

4 x M4 x 0.7 Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
20

4 x ø4.5
1P 71.6 : ø8, ø5/16"
5 5
20

Connector
L3

Circular
5EA 4A 4A
L2 Cut dimensions for panel mounting
Refer to panel cut dimensions for details.
C4, C6: 14.8
: 17.2

1/4

EX120 EX126 EX260 EX250 EX600 EX500


[1(P), 5(EA), 3(EB) port]
L3
L2 Note) These figures show the “SS5Y5-
C8

51S5-05D-C8”.

Port size 01 Port size 02 One-touch fitting (Replaceable)


38

38

38

(Pitch) (Pitch) (Pitch)


50 P = 16 50 P = 17.5 50 P = 16
(15.5)
17.5

14.5

3EB 2B
14.8

3EB 2B
9.7
40.2

40.2

40.2

3EB 2B

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


and Plug Assembly/
One-touch Fittings

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Part No.

Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
Manifold

: ø8, ø5/16"
Options

Port Size 01, C쏔, N쏔, KC쏔, KN쏔 Port Size 02


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
Specific Product

L1 84 100 116 132 148 164 180 196 212 228 244 L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
Precautions

L2 74 90 106 122 138 154 170 186 202 218 234 L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 93 101 109 117 L3 — — — — — — — 100.5 109.3 118 126.8

42
Plug-in Metal Base
EX510
Type 52
Top Ported
Series SY3000/5000
How to Order Manifold

SS5Y 3 52 S5 05 D

Series Wiring type Valve stations


3 SY3000 Nil All double wiring Note 1) Symbol Stations Note
5 SY5000 S All single wiring Note 2) 02 2 stations
All double
Note 1) All double wiring: 2-position single, double, wiring
3-position and 4-position valves can be 08 8 stations
used on all manifold stations. 02 2 stations
All single
Type Note 2) All single wiring: Available only for the
manifold which has 2-position single for all wiring
52 Top ported 12 12 stations
stations.
52R Top ported, External pilot Note that 2-position double, 3- or 4-position ∗ This also includes the number of blanking
valves cannot be used. plate assembly.
Note 3) Please contact SMC if a mixture of single wiring
and double wiring is required.
SI unit output polarity
P, E port entry
Nil Positive common
N Negative common U U side Note)
D D side Note)
B Both sides
Note) Plugs are mounted on the opposite side
of the selected ports.

Thread type
Nil Rc
How to Order Manifold Assembly 00F G
00N NPT
00T NPTF
Example (SS5Y3-52S5-쏔)
2-position double (24 VDC)
2-position single (24 VDC) SY3230-5U1-C6 (1 set)
SY3130-5U1-C6 (3 sets)
3-position closed Mounting
center (24 VDC)
Nil Direct mounting
SY3330-5U1-C6 (1 set)
D DIN rail mounting (With DIN rail)
D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations
Specify a longer rail than
the standard length.
D12 For 12 stations

ide
Us
s
n
tio
ta
S

3
2
1
Manifold base ide
(5 stations) Ds
SS5Y3-52S5-05D

SS5Y3-52S5-05D ······ 1 set (Type 52 5-station manifold base part no.)


∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.)
∗SY3330-5U1-C6 ······· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
arrangement becomes complicated, specify on a manifold specification Electric Products (CAT.E150) for details on the EX510 Gateway-
sheet. type Serial Transmission System.

43
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
One-touch fitting (Metric)
Type of actuation Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


1 2-position single Coil type C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


2 2-position double Nil Standard C3 ø3.2 One-touch fitting 쎲 —
3 3-position closed center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
4 3-position exhaust center C6 ø6 One-touch fitting 쎲 쎲
∗ Be sure to select the power saving circuit type
5 3-position pressure center
when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) long periods of time.
B∗ 4-position dual 3-port valve (N.O./N.O.) One-touch fitting (Inch)
∗ Note the specified energizing time when power
C∗ Symbol A, B port SY3000 SY5000

Lead Wire
4-position dual 3-port valve (N.C./N.O.) saving circuit is selected. Refer to page 154.
∗ Only rubber seal type is available for the
N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage N7 ø1/4" One-touch fitting 쎲 쎲

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
5 24 VDC

Seal type

EX120 EX126 EX260 EX250 EX600 EX500


0 Rubber seal Light/surge voltage suppressor
1 Metal seal Thread type
and common specification
Nil Rc
R With surge voltage suppressor (Non-polar)
F G
U With light/surge voltage suppressor (Non-polar)
N NPT
S With surge voltage suppressor (Positive common)
T NPTF
Pilot type Z With light/surge voltage suppressor (Positive common)
Nil Internal pilot ∗ Only Nil is available for M5.
NS With surge voltage suppressor (Negative common)
R External pilot NZ With light/surge voltage suppressor (Negative common)
∗ Only “Z” and “NZ” types are available for the
product with power saving circuit. Select a Type of mounting screw
Back pressure check valve valve from R, U, S or Z when the SI unit
polarity is Nil (Positive common). Select a Nil Round head combination screw
(Built-in valve type) B Hexagon socket head cap screw
valve from R, U, NS or NZ when the SI unit
Nil None output polarity is N (Negative common). K Round head combination screw (Falling-out-prevention type)
H Built-in H Hexagon socket head cap screw (Falling-out-prevention type)
∗ Only rubber seal type
∗ For “K” and “H”, the valve body cover has a
∗ The built-in valve type back pressure check
valve is not available for the 3-position type.
!0 Manual override drop prevention construction to stop the
Nil: Non-locking D: Push-turn F: Slide locking mounting screws from falling out when the
push type locking slotted type valve is removed for maintenance etc.
type ∗ When ordering a valve individually, the base
gasket is not included. Since the base gasket
is attached to the manifold, please order the
base gasket separately if it is needed for
and Plug Assembly/

maintenance service.
One-touch Fittings

Refer to page 47 for part numbers of the base


gasket and mounting screw.
Part No.

∗ "B" and "H" cannot be selected for the individual


SUP/EXH spacer assembly.
Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
44
Series SY3000/5000

Dimensions: Type 52/EX510/Series SY3000


U
SS5Y3-52(R)S5쏔- Stations D -쏔(D)
B

D side U side

DIN rail holding screw L3


(For DIN rail mounting) 5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
DIN rail bracket mounting screw

68.3
(For DIN rail mounting)
45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
(Slide locking manual override) 18.5 19.6 Light/surge voltage 4(A) port side: Blue (For rubber seal)
suppressor : Gray (For metal seal)
M5 x 0.8 (External pilot)
2(B) port side: Yellow
[Pilot EXH port]
DIN rail

B A B A B A B A B A

92.7
4A 4A 4A 4A 4A
5EA

89
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

26.6
2B 2B 2B 2B 2B
3EB

8.6 4 x ø4.5 SI unit 8


14.5 (For mounting) One-touch fitting
4 L2
[4(A), 2(B) port]
22.1 (L5) L1 Applicable tube O.D.: ø2
28 : ø3.2, ø1/8"
M5 x 0.8
: ø4, ø5/32"
1/8 [4(A), 2(B) port] : ø6, ø1/4"
[1(P), 5(EA), 3(EB) port]
(Station 1)---(Station n)
M5 x 0.8 (External pilot)
[External pilot port]
)
C6: 76.8
N7: 80.6
65.6
62.6

(
32

52RS5쏔- Stations UD
(For DIN rail
mounting)
7.5
11.8

3
[Plug for external pilot]

Note) These figures show the “SS5Y3-52S5-05B”.

∗The above drawing shows when P,


E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

45
Series SY3000/5000

Construction Specifications
Plug-in Metal Base

Dimensions: Type 52/EX510/Series SY5000

Replacement
U
SS5Y5-52(R)S5쏔- Stations D -쏔(D)

Parts
B

Metal Base
D side U side

Plug-in
L3
DIN rail holding screw 5.3 L4
(For DIN rail mounting) (DIN rail mounting hole pitch: 12.5) Manual override
DIN rail bracket mounting screw (Pitch)

Flat Ribbon Cable


( )

D-sub Connector
Push-turn locking slotted type:
(For DIN rail mounting) 50 P = 16 Press, then rotate it.

PC Wiring
74.3 20.5 19.6 4(A) port side: Blue (For rubber seal)
(Slide locking manual override) Light/surge voltage : Gray (For metal seal)
68.6

EX510
M5 x 0.8 (External pilot) suppressor 2(B) port side: Yellow
[Pilot EXH port]

01 : 16.2
C쏔 : 14.5
DIN rail

5.5

Terminal D-sub Connector Plug-in Connector


Connecting Base
B A B A B A B A B A
4A 4A 4A 4A 4A
PE
5EA

106.2
23.2

116.6
35
96.2

20
81.6

74.1
20
1P
24.6
20

43.8
40.2

40.2
3EB

30.2

Flat Ribbon Cable


X

2B 2B 2B 2B 2B 8

Block Box PC Wiring


12.3 1/8
18 4 x ø4.5 SI unit [4(A), 2(B) port]
(For mounting) One-touch fitting
28 5 L2
[4(A), 2(B) port]
34 (L5) L1 Applicable tube O.D.: ø4, ø5/32"

Lead Wire
1/4 : ø6, ø1/4"
[1(P), 5(EA), 3(EB) port] : ø8, ø5/16"

M5 x 0.8 (External pilot)


[External pilot port] (Station 1)----------- (Station n)

Connector
Circular
EX120 EX126 EX260 EX250 EX600 EX500
(86.7)
72.3

52RS5쏔- Stations UD
71.6

38

3
(For DIN rail

[Plug for external pilot]


mounting)
10
14.3

Note) These figures show the “SS5Y5-52S5-05B”.


∗The above drawing shows when P,
E port entry is D.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold
Options

L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
Specific Product

L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
Precautions

L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

46
Series SY3000/5000 Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View
q

Tightening torque: 1.4 N·m

Tightening torque: 1.4 N·m w

Holding screw

e It is mounted only for the DIN rail


mounting type (with DIN rail).

r It is mounted only for the DIN rail mounting type.


(Tightening torque of holding screw: 1.4 N·m)
Caution
Tightening torque
M2: 0.16 N·m
M3: 0.8 N·m

Manifold Parts No.

Part no.
No. Description Note
SY3000 SY5000
Round head SY3000-23-24A SY5000-221-1A
combination screw Part numbers shown on the left are for 10 valves (20 pcs.).
(M2 x 32) (M3 x 32.5)
q Valve mounting screw
Hexagon socket SY3000-222-1A SY5000-222-1A
head cap screw Part numbers shown on the left are for 10 valves (20 pcs.).
(M2 x 32) (M3 x 32.5)
w Base gasket (for plug-in metal base) SY30M-11-1A SY50M-11-1A Part numbers shown on the left are for 10 valves (10 pcs.).
e DIN rail VZ1000-11-1-쏔 VZ1000-11-4-쏔 Refer to page 140.
Clamp bracket assembly (for plug-in metal Part numbers shown on the left are for the clamp bracket
r SY30M-15-2A SY50M-15-2A
base) assembly for one manifold (two sets of clamp brackets).

쐽Blanking plate assembly (With two mounting screws) How to Order Blanking Plate Assembly
Used when expecting valve additions, or for maintenance. A
structure to prevent screws falling out is in place on the blanking
SY 0M 26 2 A
plate, making it much harder for the mounting screws to fall out. Series
3 SY3000 Option for mounting
5 SY5000 With mounting screw
Nil (Round head combination screw)
With mounting screw
B (Hexagon socket head cap screw)
(A) (B)
4 2
Base type
2 For plug-in metal base
SY30M-26-2A(-B) SY50M-26-2A(-B) 5 1 3
Refer to pages 149 and 151 for dimensions. (EA) (P) (EB)
Circuit diagram
Refer to pages 141 to 148 for individual SUP/EXH and other options.

47
Plug-in Connector Connecting Base
Type 10
Side Ported D-sub Connector Flat Ribbon Cable PC Wiring

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 10 F 1 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series Type Connector entry direction


3 SY3000 10 Side ported 1: Upward 2: Lateral
5 SY5000 11 Bottom ported∗
∗ The SY5000 manifold base is used for
the bottom ported of the SY3000. When
ordering, refer to Plug-in Mixed Mounting LOC
K
LOC
K
Type Manifold (from page 127). FRE
E
FRE
E

Connector type
F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable
(25 pins) (26 pins) (20 pins) Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
Symbol Stations Note Symbol Stations Note
LOC
K
LOC
K
LOC
K 02 2 stations 02 2 stations
FRE
E
FRE
E
FRE
E Double wiring Note 1) Double wiring Note 1)
12 12 stations 12 12 stations
02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
PH: Flat ribbon cable J: PC wiring (20 pins)
(Available up to (Available up to
(10 pins) Yellow ink
24 24 stations 24 solenoids) 24 24 stations 24 solenoids)
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
LOC
K
LOC
K
Symbol Stations Note Symbol Stations Note
FRE
E
FRE
E 02 2 stations 02 2 stations
Double wiring Note 1) Double wiring Note 1)
09 9 stations 04 4 stations
02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
How to Order Manifold Assembly (Available up to (Available up to
18 18 stations 18 solenoids) 08 8 stations 8 solenoids)
Example (SS5Y3-10F1-쏔) J: PC wiring (20 pins) Note 1) Double wiring: 2-position
2-position double (24 VDC) Symbol Stations Note single, double, 3-position
2-position single (24 VDC) SY3200-5U1 (1 set) 02 2 stations and 4-position valves can be
SY3100-5U1 (3 sets) 3-position closed Double wiring Note 1) used on all manifold
center (24 VDC) stations.
08 8 stations Use of a 2-position single
SY3300-5U1 (1 set)
02 2 stations Specified layout Note 2) solenoid will result in an
(Available up to unused control signal. If this
16 16 stations 16 solenoids) is not desired, order with a
specified layout.
LOC
K
Note 2) Specified layout: Indicate the wiring specifications on the manifold
ide specification sheet. (Note that 2-position double, 3-position and 4-
FRE
E Us
s position valves cannot be used where single wiring has been specified.)
at ion Note 3) This also includes the number of blanking plate assembly.
St
Manifold base 3
(5 stations) 2
1
SS5Y3-10F1-05D-C6 id e P, E port entry SUP/EXH block assembly
Ds U U side (2 to 10 stations)
Nil Internal pilot
D D side (2 to 10 stations)
S Internal pilot, Built-in silencer
SS5Y3-10F1-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) B Both sides (2 to 24 stations)
∗SY3100-5U1················· 3 sets (2-position single part no.) R External pilot
∗SY3200-5U1················· 1 set (2-position double part no.) Refer to the page on the right for . ∗ 3/5(E) port is plugged for the built-
∗SY3300-5U1················· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
o Mounting and Option in silencer type.

Symbol Mounting Option DIN Rail Option


Prefix it to the part nos. of the valve, etc.
Nil None Nil Direct mounting
• The valve arrangement is numbered as the 1st station from the D side. Direct 0 Without DIN rail (with bracket)
AA mounting
Name plate (With station number)
• Under the manifold part number, state the valves to be mounted in order 3 For 3 stations Specify a longer rail
from the 1st station as shown in the figure above. If the arrangement be-
BA Name plate (Without station number)
D첸 Without name plate than the total length
comes complicated, specify on a manifold specification sheet. DIN rail
A첸 Name plate (With station number) 24 For 24 stations of specified stations.
Note) When mixing top ported configurations, select from page 56. mounting
B첸 Name plate (Without station number)
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B Note 1) Enter the number of stations inside 첸. (Refer to “DIN Rail Option” below.)
port on base side. Note 2) Only direct mounting is available for Type 11 (Bottom ported).
49
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
Symbol A, B port Symbol A, B port

Flat Ribbon Cable


D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow Note)
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow Note)

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —


Flat Ribbon Cable


B6 ø6 One-touch fitting 쎲 쎲 — BN9 ø5/16" One-touch fitting — —
B8 ø8 One-touch fitting — 쎲 — Elbow port, mixed sizes

Block Box PC Wiring


LM∗ (Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Lead Wire
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000
Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
4 3-position exhaust center pressure type.
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.)
B∗ 4-position dual 3-port valve (N.O./N.O.)
Nil Standard
C∗ 4-position dual 3-port valve (N.C./N.O.)
T With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve.
when the valve is continuously energized for
long periods of time. Type of mounting screw
Seal type
∗ Note the specified energizing time when power Nil Round head combination screw
0 Rubber seal
saving circuit is selected. Refer to page 154. B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot 6 12 VDC drop prevention construction to stop the
R External pilot
mounting screws from falling out when the
Light/surge voltage suppressor
and Plug Assembly/

valve is removed for maintenance etc.


One-touch Fittings

Back pressure check valve and common specification ∗ When ordering a valve individually, the base
(Built-in valve type) Nil gasket is not included. Since the base gasket
Part No.

Without light/surge voltage suppressor (Non-polar)


Nil None R With surge voltage suppressor (Non-polar) is attached to the manifold, please order the
H Built-in base gasket separately if it is needed for
U With light/surge voltage suppressor (Non-polar)
Manifold

maintenance service.
Options

∗ Only rubber seal type. Manifold installed type S With surge voltage suppressor (Positive common) Refer to page 136 for part numbers of the base
is available if the back pressure check valve Z With light/surge voltage suppressor (Positive common) gasket and mounting screw.
is required for a valve with metal seal. Refer
NS With surge voltage suppressor (Negative common) ∗ “B” and “H” cannot be selected for the individual
to page 147 for Ordering Example. However,
NZ With light/surge voltage suppressor (Negative common) SUP/EXH spacer assembly or double check spacer
it is not recommended to use the built-in valve
Specific Product

assembly with residual pressure release valve.


type and the manifold installed type at the ∗ Only “Z” and “NZ” types are available for the
Precautions

same time because it will reduce the flow. product with power saving circuit.
Protective class
∗ The built-in valve type back pressure check
class (Mark: )
valve is not available for the 3-position type.
50
Series SY3000/5000

Dimensions: Type 10/D-sub Connector/Series SY3000


C2
U
SS5Y3-10F 21 - Stations D - C3, N1
C4, N3 (D)
B C6, N7
D side U side
Manual override Note 2)
DIN rail holding screw (L5)
(For DIN rail mounting) (8)
L1
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent Light/surge voltage suppressor : Gray (For metal seal)
2(B) port side: Yellow

5.5
8
LOCK

B A B A B A B A B A

92.6
14 A 14 A 14 A 14 A 14 A

70.6

35
83

60.5
FREE
44.8

40.9
4.6
12 B 12 B 12 B 12 B 12 B

2 x M2.6
4.6
9.5

1.7
)
(4.9)

C6: 3.6
N7: 7.4
2 x 4-40 UNC
(Connector entry
[4(A), 2(B) with 4 x M4 mounting hole
inch size ports] upward direction)
19.6 ( L2 1.5
(Fitting for the type with P/E
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
(Station 1)---(Station n) : ø3.2, ø1/8"
6.1 : ø4, ø5/32"
: ø6, ø1/4"

1 P 1 P
(62.7)

13.6
10.6

63.1
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
7.5

One-touch fitting (Pitch)


11.8

[1(P), 3/5(E) port] 31.4 15.5 P = 10.5 (17.8)


Applicable tube O.D.: ø8, ø5/16"

Note 1) These figures show the “SS5Y3-10F2-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5

51
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/D-sub Connector/Series SY5000

Replacement
U C4, N3
SS5Y5-10F 21 - Stations D - C6, N7 (D)

Parts
B C8, N9

D side U side

Metal Base
Manual override Note 2)
(L5) L1
( )

Plug-in
DIN rail holding screw Push-turn locking slotted type:
(8) Press, then rotate it.
(For DIN rail mounting)
4(A) port side: Blue (For rubber seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail
Light/surge voltage suppressor
: Gray (For metal seal)

Flat Ribbon Cable


2(B) port side: Yellow

D-sub Connector

PC Wiring
8

5.5

EX510
LOCK

BA BA BA BA BA
70.6 14 A 14 A 14 A 14 A 14 A

35
97.5

113.4
FREE

81.2

Terminal D-sub Connector Plug-in Connector


Connecting Base
65.6

61.7
5.5
12 B 12 B 12 B 12 B 12 B
10.9
30.3

4.7

Flat Ribbon Cable


2 x M2.6 (5.9)
(8.3)

4 x M5 mounting hole
2 x 4-40 UNC

Block Box PC Wiring


[4(A), 2(B) with 21.9 L2 1.5 (Fitting for the type with P/E
inch size ports] ports on the U and/or D sides)
5.3 L4
(Connector entry upward direction) (DIN rail mounting hole pitch: 12.5)
L3

Lead Wire
One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"

Connector
: ø6, ø1/4"

Circular
: ø8, ø5/16"
6.1

EX120 EX126 EX260 EX250 EX600 EX500


1 P 1 P
14.1

73.2
(62.7)

8.7

2 B2 B2 B2 B2 B
56.6
48.6

12.4
33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A

One-touch fitting
(For DIN rail
mounting)

(Pitch)
7.5

[1(P), 3/5(E) port]


11.8

Applicable tube O.D.: ø10, ø3/8" 35.9 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10F2-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold
Options

L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
Specific Product

L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
Precautions

L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22

52
Series SY3000/5000

Dimensions: Type 10/Flat Ribbon Cable/Series SY3000


P C2
U
SS5Y3-10 PG 1 C3, N1
PH 2 - Stations D - C4, N3 (D) D side U side
J B C6, N7
(L5) L1 Manual override Note 2)

(Connector entry upward direction)


DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
Light/surge : Gray (For metal seal)
Triangle mark DIN rail (8)
2(B) port side: Yellow
voltage suppressor

8
LOCK

B A B A B A B A B A

5.5

92.6
14 A 14 A 14 A 14 A 14 A

70.6

35
83

60.5
FREE
44.8

40.9
4.6
12 B 12 B 12 B 12 B 12 B
4.6
9.5

1.7
(4.9)

)
(Fitting for the type

C6: 3.6
N7: 7.4
Applicable connector:
with P/E ports on the
26 pins MIL type with strain relief
U and/or D sides)
(Conforming to MIL-C-83503) 19.6 ( L2 1.5 4 x M4 mounting hole
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
One-touch fitting
(Station 1)---(Station n) [4(A), 2(B) port]
Applicable tube O.D.: ø2
18.8
: ø3.2, ø1/8"
: ø4, ø5/32"
1 P 1 P
: ø6, ø1/4"
(75.4)

10.6
13.6

63.1
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(Pitch) (For DIN rail


7.5

One-touch fitting 31.4 15.5 P = 10.5 (17.8) mounting)


11.8

[1(P), 3/5(E) port]


Applicable tube O.D.: ø8, ø5/16"

Note 1) These figures show the “SS5Y3-10P2-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.
Note 4) Only connectors are different for 10PG, 10PH and 10J. L1 to L5 dimensions are the same as 10P type.

10PJG (20 pins) 10PH (10 pins)


For PC wiring
Triangle mark Triangle mark
LOCK

LOCK
PCW type

FREE

FREE

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5
53
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/Flat Ribbon Cable/Series SY5000

Replacement
P
U C4, N3
SS5Y5-10 PG 1
PH 2 - Stations D - C6, N7 (D)

Parts
D side U side
J B C8, N9 Manual override Note 2)
(L5) L1
DIN rail holding screw
(
Push-turn locking slotted type:
)

Metal Base
(8) Press, then rotate it.
(Connector entry upward direction) (For DIN rail mounting)
Light/surge voltage suppressor 4(A) port side: Blue (For rubber seal)

Plug-in
Triangle mark DIN rail : Gray (For metal seal)
2(B) port side: Yellow

Flat Ribbon Cable


D-sub Connector
8

5.5

PC Wiring
LOCK

BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A

70.6

35
97.5

113.4

EX510
FREE

81.2
65.6

61.7
5.5
12 B 12 B 12 B 12 B 12 B

Terminal D-sub Connector Plug-in Connector


Connecting Base
30.3
10.9

4 x M5 mounting hole

4.7
(5.9)
(8.3)
Applicable connector: (Fitting for the type with P/E
26 pins MIL type with strain relief 21.9 L2 1.5
ports on the U and/or D sides)

Flat Ribbon Cable


(Conforming to MIL-C-83503) 5.3 L4

Block Box PC Wiring


(DIN rail mounting hole pitch: 12.5)
L3 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
(Station 1)----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
18.8

Lead Wire
14.1
1 P 1 P

73.2
8.7
(75.4)
56.6

2 B2 B2 B2 B2 B
48.6

Connector
12.4
33.4

3/5 E 3/5 E

Circular
29.1
4 A4 A4 A4 A4 A

EX120 EX126 EX260 EX250 EX600 EX500


(For DIN rail
One-touch fitting

mounting)
7.5
(Pitch)
[1(P), 3/5(E) port]
11.8
35.9 18 P = 16 (20.5)
Applicable tube O.D.: ø10, ø3/8"

10PJG (20 pins) 10PH (10 pins)


Note 1) These figures show the “SS5Y5-10P2-05D-C8”. For PC wiring Triangle mark
Note 2) Refer to page 122 for dimensions of external pilot, silencer, Triangle mark
elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
Note 4) Only connectors are different for 10PG, 10PH and 10J.
LOCK

L1 to L5 dimensions are the same as 10P type.


LOCK
PCW type

FREE
FREE

Applicable connector: Applicable connector:


and Plug Assembly/
One-touch Fittings

20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
Part No.
Manifold
Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
Specific Product

L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
Precautions

L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22
54
Plug-in Connector Connecting Base
D-sub Connector Flat Ribbon Cable PC Wiring

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12 F 1 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series Connector entry direction


3 SY3000 1: Upward 2: Lateral
5 SY5000

Connector type
F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable LOC
K
LOC
K

(25 pins) (26 pins) (20 pins) FRE


E
FRE
E

LOC LOC LOC


K
FRE
K
FRE
K
FRE
Valve stations
E E E

F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)


Symbol Stations Note Symbol Stations Note
PH: Flat ribbon cable J: PC wiring 02 2 stations 02 2 stations
(10 pins) (20 pins) Double wiring Note 1) Double wiring Note 1)
12 12 stations 12 12 stations
02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
LOC LOC
K K (Available up to (Available up to
FRE PC FRE
E W ty
pe
E
24 24 stations 24 solenoids) 24 24 stations 24 solenoids)
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
Symbol Stations Note Symbol Stations Note
P, E port entry
02 2 stations 02 2 stations
U Note) U side (2 to 10 stations) Note) y For type “S”, supply/exhaust Double wiring Note 1) Double wiring Note 1)
D Note) D side (2 to 10 stations) block assembly with built-in 09 9 stations 04 4 stations
B Both sides (2 to 24 stations) silencer, choose U or D for P 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
port entry. (Available up to (Available up to
18 18 stations 18 solenoids) 08 8 stations 8 solenoids)
How to Order Manifold Assembly Note 1) Double wiring: 2-position
J: PC wiring (20 pins)
Symbol Stations Note
single, double, 3-position
and 4-position valves can be
Example (SS5Y3-12F1-쏔) 02 2 stations used on all manifold
2-position double (24 VDC) Double wiring Note 1) stations.
2-position single (24 VDC) SY3230-5U1-C6 (1 set)
SY3130-5U1-C6 (3 sets) 08 8 stations Use of a 2-position single
3-position closed 02 2 stations Specified layout Note 2) solenoid will result in an
center (24 VDC) (Available up to unused control signal. If this
SY3330-5U1-C6 (1 set) 16 solenoids) is not desired, order with a
16 16 stations specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the manifold
specification sheet. (Note that 2-position double, 3-position and 4-
position valves cannot be used where single wiring has been specified.)
LOC Note 3) This also includes the number of blanking plate assembly.
K
ide
FRE
E Us
s

P, E port size
n
tio
ta

SUP/EXH block assembly


S

(One-touch fittings)
3

Manifold base Nil Internal pilot


2

(5 stations) Symbol SY3000 SY5000


1

ide S Internal pilot,Built-in silencer


SS5Y3-12F1-05D Ds Nil
R External pilot ø8 ø10
SS5Y3-12F1-05D ······ 1 set (Type 12 5-station manifold base part no.) ∗ For built-in silencer type, P and E N ø5/16" ø3/8"
∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.) ports are available on U and D
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.) sides. 3/5(E) port is plugged. The ∗ For N, sizes are in inches.
∗SY3330-5U1-C6 ········ 1 set (3-position closed center part no.) silencer exhaust port is located
The asterisk denotes the symbol for assembly. on the opposite side of P, E port Mounting
Prefix it to the part nos. of the valve, etc. entry. (Example: When the P, E Nil Direct mounting
port entry is D side, the silencer D DIN rail mounting (With DIN rail)
• The valve arrangement is numbered as the 1st station from the D side.
exhaust port is U side.)
• Under the manifold part number, state the valves to be mounted in order D0 DIN rail mounting (Without DIN rail)
from the 1st station as shown in the figure above. D3 For 3 stations Specify a longer
If the arrangement becomes complicated, specify on a manifold rail than the
specification sheet.
D24 For 24 stations standard length.
55
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Coil type C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center Nil Standard C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center ∗ Be sure to select the power saving circuit type
C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) long periods of time. One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Note the specified energizing time when power Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the saving circuit is selected. Refer to page 154.
N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage N7 ø1/4" One-touch fitting 쎲 쎲

Connector
5 N9 ø5/16" One-touch fitting — 쎲

Circular
24 VDC
Seal type 6 12 VDC
0 Rubber seal

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
Light/surge voltage suppressor Nil Rc
and common specification F G
Nil Without light/surge voltage suppressor (Non-polar) N NPT
Pilot type
R With surge voltage suppressor (Non-polar) T NPTF
Nil Internal pilot
U With light/surge voltage suppressor (Non-polar) ∗ Only Nil is available for M5.
R External pilot
S With surge voltage suppressor (Positive common)
Z With light/surge voltage suppressor (Positive common)
Back pressure check valve NS With surge voltage suppressor (Negative common)
Type of mounting screw
(Built-in valve type) NZ With light/surge voltage suppressor (Negative common)
Nil Round head combination screw
Nil None ∗ Only “Z” and “NZ” types are available for the
B Hexagon socket head cap screw
H Built-in product with power saving circuit.
K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve
is required for a valve with metal seal. Refer !0 Manual override ∗ For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
to page 147 for Ordering Example. However,
it is not recommended to use the built-in valve Nil: Non-locking D: Push-turn F: Slide locking mounting screws from falling out when the
type and the manifold installed type at the push type locking slotted type valve is removed for maintenance etc.
same time because it will reduce the flow. type ∗ When ordering a valve individually, the base
∗ The built-in valve type back pressure check gasket is not included. Since the base gasket
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the individual
Part No.

SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
56
Series SY3000/5000

Electrical Wiring Specifications Cable Assembly


015
D-sub connector
AXT100-DS25- 030
050 Lead wire color for
If alignment is not specified, the internal D-sub connector
14
1 wiring is double wiring (connected to SOL. cable assembly by
2
15
3 a and SOL. b) regardless of number of terminal number
16
17
4 stations, valve and option types. Cable
5 Lead Dot
18 0.3 mm2 x 25 cores Terminal
6 wire
no. marking
19
7 O.D. ø1.4 color
20
21
8
Approx. ø10 1 Black None
9
22
23
10 2 Brown None
11
24
12
3 Red None
25 Lead wire color for Seal (Length)
13
015 4 Orange None
D-sub connector assembly 5 Yellow None
Connector terminal no. 015

L
(AXT100-DS25- 030
050
) Molded cover 6 Pink None
Lead wire Dot 2 x M2.6 x 0.45 7 Blue None

44
Terminal no. Polarity color marking 8 Purple White
SOL.a
1 (–) (+) Black None Connector DB-25SF-N 9 Gray Black
Station 1 SOL.b

8
14 (–) (+) Yellow Black made by Japan Aviation 10 White Black
SOL.a Electronics Industry, Ltd.
2 (–) (+) Brown None 11 White Red

(2.4)
Station 2 SOL.b 55
15 (–) (+) Pink Black 12 Yellow Red
SOL.a Socket side
3 (–) (+) Red None 14 25 13 Orange Red
Station 3 SOL.b
16 (–) (+) Blue White 14 Yellow Black
16 Terminal no.
SOL.a 15 Pink Black
4 (–) (+) Orange None
Station 4 SOL.b 16 Blue White
17 (–) (+) Purple None 1 13
SOL.a 5 47.04 17 Purple None
(–) (+) Yellow None
Station 5 SOL.b 18 Gray None
18 (–) (+) Gray None
SOL.a 19 Orange Black
6 (–) (+) Pink None
Station 6 SOL.b 20 Red White
19 (–) (+) Orange Black
SOL.a 21 Brown White
7 (–) (+) Blue None D-sub connector cable assembly
Station 7 SOL.b 22 Pink Red
20 (–) (+) Red White
SOL.a Cable 23 Gray Red
8 (–) (+) Purple White Assembly part no. Note
Station 8 length (L) 24 Black White
SOL.b
21 (–) (+) Brown White 1.5 m AXT100-DS25-015 25 White None
SOL.a Cable
9 (–) (+) Gray Black 3m AXT100-DS25-030
Station 9 SOL.b 0.3 mm2 x 25 cores
22 (–) (+) Pink Red 5m AXT100-DS25-050
SOL.a 10 (–) (+) White Black ∗ When using a standard commercial
Station 10 SOL.b
23 (–) (+) Gray Red connector, use a 25-pin type female
SOL.a 11 connector conforming to MIL-C-24308.
(–) (+) White Red
Station 11 SOL.b ∗ Cannot be used for movable wiring.
24 (–) (+) Black White
SOL.a ∗ Lengths other than the above are also
12 (–) (+) Yellow Red available. Please contact SMC for details.
Station 12 SOL.b
25 (–) (+) White None
COM. (+) (–)
Electrical characteristics Connector Manufacturers’ Example
13 Orange Red
Item Property • Fujitsu, Ltd.
Positive Negative
common common Conductor resistance • Japan Aviation Electronics Industry, Ltd.
액/km, 20°C 65 or less
• J.S.T. Mfg. Co., Ltd.
Note) When using a valve with no polarity, either positive common or • Hirose Electric Co., Ltd.
Voltage limit
negative common can be used. V, 1 minute, AC 1000

Insulation resistance
M액/km, 20°C 5 or more
Specified Layout
Note) The minimum bending
(25 pins) Mixed wiring of single and double wiring radius of the D-sub
can be specified on the manifold connector cable is 20 mm.
1
14 2 specification sheet. The maximum
15 3
16 4
number of stations is determined
17
18
5 according to the number of solenoids.
6
19
20
7 The total number of solenoids should be
8
21 9 24 or less. 1 solenoid is required for 2-
22 10
23 11
position single, and 2 solenoids for 2-
24
25
12 position double, 3-position and 4-position.
13

COM.

57
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Electrical Wiring Specifications Cable Assembly

Parts
Flat ribbon cable connector 10 1
AXT100-FC 20 - 2
If alignment is not specified, the internal 26 3
26 25

Metal Base
wiring is double wiring (connected to SOL.
24 23 6 Terminal no. 28AWG
a and SOL. b) regardless of number of

Plug-in
22 21
20 19
stations, valve and option types. Red
18 17

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
16 15
14 13

Flat Ribbon Cable


D-sub Connector
12 11
10 9

PC Wiring
8 7

26

25
6 5 Connector terminal no.
4 3

EX510
2 1
Triangle mark indicator position (15.6)

L
P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)

Terminal D-sub Connector Plug-in Connector


Connecting Base
<Double wiring> <Double wiring> Flat ribbon cable connector assembly
Terminal Polarity Terminal Polarity Cable Assembly part no.
no. no. length (L)
SOL.a SOL.a 26 pins 20 pins 10 pins
1 (–) (+) 1 (–) (+)
Station 1 SOL.b Station 1 SOL.b 1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
2 (–) (+) 2 (–) (+)
SOL.a (–) (+) SOL.a (–) (+) 3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2
3 3

Flat Ribbon Cable


Station 2 SOL.b Station 2 SOL.b 5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3
4 (–) (+) 4 (–) (+)
SOL.a SOL.a

Block Box PC Wiring


5 (–) (+) 5 (–) (+) ∗ When using a standard commercial connector, use a 26-pin, 20-pin or
Station 3 SOL.b Station 3 SOL.b 10-pin type connector conforming to MIL-C-83503 with strain relief.
6 (–) (+) 6 (–) (+)
SOL.a
7 (–) (+) SOL.a
7 (–) (+) ∗ Cannot be used for movable wiring.
Station 4 SOL.b Station 4 SOL.b ∗ Lengths other than the above are also available. Please contact SMC for
8 (–) (+) 8 (–) (+)
SOL.a SOL.a details.
9 (–) (+) 9 (–) (+)
Station 5 SOL.b Station 5 SOL.b
10 (–) (+) 10 (–) (+)
SOL.a SOL.a Connector Manufacturers’ Example

Lead Wire
11 (–) (+) 11 (–) (+)
Station 6 SOL.b Station 6 SOL.b
12 (–) (+) 12 (–) (+)
SOL.a SOL.a • Hirose Electric Co., Ltd.
13 (–) (+) 13 (–) (+)
Station 7 SOL.b Station 7 SOL.b
• Sumitomo 3M Limited
14 (–) (+) 14 (–) (+) • Fujitsu, Ltd.

Connector
SOL.a 15 (–) (+) SOL.a 15 (–) (+) • Japan Aviation Electronics Industry, Ltd.

Circular
Station 8 SOL.b Station 8 SOL.b
16 (–) (+) 16 (–) (+) • J.S.T. Mfg. Co., Ltd.
SOL.a 17 (–) (+) SOL.a 17 (–) (+) • Oki Electric Cable Co., Ltd..
Station 9 SOL.b Station 9 SOL.b
18 (–) (+) 18 (–) (+)

EX120 EX126 EX260 EX250 EX600 EX500


SOL.a 19 (–) (+) COM. 19 (+) (–)
Station 10 SOL.b 20 (–) (+) COM. 20 (+) (–)
SOL.a 21 (–) (+)
Station 11 SOL.b 22 (–) (+) Positive Negative Specified Layout
common common
SOL.a 23 (–) (+)
Station 12 SOL.b COM. COM.
24 (–) (+)
COM. 26 25
25 (+) (–) J: Flat ribbon cable (20 pins) 23
COM. 24 COM. COM.
26 (+) (–) PC wiring 22 21
20 19 20 19
Positive Negative <Double wiring>
common common 18 17 18 17
Terminal Polarity 16 15 16 15
no.
SOL.a 14 13 14 13 COM. COM.
20 (–) (+)
Station 1 SOL.b 12 11 12 11
18 (–) (+)
PH: Flat ribbon cable (10 pins) SOL.a 10 9 10 9 10 9
16 (–) (+) 8 7 8 7 8 7
<Double wiring> Station 2 SOL.b
14 (–) (+) 6 5 6 5 6 5
Terminal Polarity SOL.a
12 (–) (+) 4 3 4 3 4 3
no. Station 3 SOL.b 2 1 2 1 2 1
SOL.a 10 (–) (+)
1 (–) (+)
Station 1 SOL.b SOL.a
8 (–) (+)
2 (–) (+) Station 4
SOL.a SOL.b (–) (+) (26 pins) (20 pins) (10 pins)
3 (–) (+) 6
Station 2 SOL.b SOL.a 19 (–) (+)
4 (–) (+) Station 5
SOL.a SOL.b (–) (+)
5 (–) (+) 17 Mixed wiring of single and double
Station 3 SOL.b SOL.a 15 (–) (+) 20 19
6 (–) (+) Station 6 SOL.b 18 17
wiring can be specified on the manifold
SOL.a 13 (–) (+)
and Plug Assembly/

7 (–) (+) specification. The maximum number of


One-touch Fittings

Station 4 SOL.a 16 15
SOL.b (–) (+) 11 (–) (+)
8 Station 7 14 13 stations is determined according to the
SOL.b (–) (+)
COM. 9 12 11
Part No.

9 (+) (–) SOL.a number of solenoids. The total number


7 (–) (+) 10 9
COM. (+) (–) Station 8 of solenoids should be 24 or less. 1
10 SOL.b (–) (+) 8 7
5
solenoid is required for 2-position
Manifold

6 5
Options

Positive Negative 4
common common 3
4 3 single, and 2 solenoids for 2-position
2 1
double, 3-position and 4-position.
COM. 2 (+) (–) COM. COM.
COM. 1 (+) (–) (20 pins PC wiring)
Specific Product

Note) When using a valve with


Positive Negative
Precautions

no polarity, either positive common common


common or negative
common can be used.

58
Type 10 Plug-in Connector Connecting Base
Side Ported Terminal Block Box

SY3000/5000
Type 11
Bottom Ported
Series
How to Order Manifold

SS5Y 3 10 T 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series Valve stations P, E port entry


3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring Note 1) B Both sides (2 to 20 stations)
10 10 stations
02 2 stations
Specified layout Note 2)
Type (Available up to 20 solenoids)
10 Side ported 20 20 stations SUP/EXH block assembly
11 Bottom ported∗ Note 1) Double wiring: 2-position single, double, 3- Nil Internal pilot
position and 4-position valves can be S Internal pilot, Built-in silencer
∗ The SY5000 manifold base is used for the
used on all manifold stations. R External pilot
bottom ported of the SY3000. When ordering,
Use of a 2-position single solenoid will
refer to Plug-in Mixed Mounting Type ∗ 3/5(E) port is plugged for the built-in silencer
result in an unused control signal. If this is
Manifold (from page 127). type.
not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring ∗ When the built-in silencer type is used, keep
specifications with the manifold the exhaust port from coming in direct contact
specification sheet. (Note that 2-position with water or other liquids.
double, 3-position and 4-position valves
cannot be used where single wiring has Refer to the page on the right for .
been specified.)
Note 3) This also includes the number of blanking
plate assembly.

How to Order Manifold Assembly Mounting and Option


Symbol Mounting Option
None
Direct
Example (SS5Y3-10T-쏔) mounting
Name plate (With station number)
2-position double (24 VDC) Name plate (Without station number)
SY3200-5U1 (1 set) Without name plate
2-position single (24 VDC) DIN rail
3-position closed Name plate (With station number)
SY3100-5U1 (3 sets) mounting
center (24 VDC) Name plate (Without station number)
SY3300-5U1 (1 set) Note 1) Enter the number of stations inside 첸.
(Refer to “DIN Rail Option” below.)
Note 2) Only direct mounting is available for Type
11 (Bottom ported).
DIN Rail Option
ide
Us Nil Direct mounting
on
s 0 Without DIN rail (with bracket)
ati
St 3 For 3 stations
3 Specify a longer rail than the
2
1 total length of specified stations.
ide 24 For 24 stations
Ds
Manifold base
(5 stations)
SS5Y3-10T-05D-C6

SS5Y3-10T-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1··············· 3 sets (2-position single part no.)
∗SY3200-5U1··············· 1 set (2-position double part no.)
∗SY3300-5U1··············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 64.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
59
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported

Flat Ribbon Cable


Symbol A, B port Symbol A, B port

D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow Note)
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow Note)

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —

Flat Ribbon Cable


B6 ø6 One-touch fitting 쎲 쎲 — BN9 ø5/16" One-touch fitting — 쎲 —
B8 ø8 One-touch fitting — 쎲 — Elbow port, mixed sizes

Block Box PC Wiring


LM∗ (Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting

Lead Wire
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
Circular
SY 3 1 0 0 5 1

EX120 EX126 EX260 EX250 EX600 EX500


Series
3 SY3000 Base mounted
5 SY5000
Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
4 3-position exhaust center pressure type.
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.)
B∗ 4-position dual 3-port valve (N.O./N.O.)
Nil Standard
C∗ 4-position dual 3-port valve (N.C./N.O.)
T With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve.
when the valve is continuously energized for Type of mounting screw
Seal type long periods of time.
Nil Round head combination screw
∗ Note the specified energizing time when power
0 Rubber seal saving circuit is selected. Refer to page 154. B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot 6 12 VDC drop prevention construction to stop the
R External pilot mounting screws from falling out when the
Light/surge voltage suppressor valve is removed for maintenance etc.
and Plug Assembly/
One-touch Fittings

Back pressure check valve and common specification ∗ When ordering a valve individually, the base
(Built-in valve type) gasket is not included. Since the base gasket
Nil
Part No.

Without light/surge voltage suppressor (Non-polar) is attached to the manifold, please order the
Nil None R With surge voltage suppressor (Non-polar) base gasket separately if it is needed for
H Built-in U With light/surge voltage suppressor (Non-polar) maintenance service.
Manifold
Options

∗ Only rubber seal type. Manifold installed type S With surge voltage suppressor (Positive common) Refer to page 136 for part numbers of the
is available if the back pressure check valve Z With light/surge voltage suppressor (Positive common) base gasket and mounting screw.
is required for a valve with metal seal. Refer ∗ "B" and "H" cannot be selected for the
to page 147 for Ordering Example. However, NS With surge voltage suppressor (Negative common)
individual SUP/EXH spacer assembly or double
it is not recommended to use the built-in valve NZ With light/surge voltage suppressor (Negative common) check spacer assembly with residual pressure
Specific Product

type and the manifold installed type at the ∗ Only “Z” and “NZ” types are available for the release valve.
Precautions

same time because it will reduce the flow. product with power saving circuit.
Protective class
∗ The built-in valve type back pressure check
class (Mark: )
valveis not available for the 3-position type.
60
Series SY3000/5000

Dimensions: Type 10/Terminal Block Box/Series SY3000


C2
U
SS5Y3-10T- Stations D - C3, N1
C4, N3 (D)
B C6, N7

D side U side

(L5) L1
Manual override Note 2)
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
DIN rail 4(A) port side: Blue (For rubber seal)
Light/surge : Gray (For metal seal)
voltage suppressor 2(B) port side: Yellow
D side

U side
8
B A B A B A B A B A

5.5
14 A 14 A 14 A 14 A 14 A

35
126

83

92.6
80

60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B

20.4
4.6
1.7
16

)
(4.9)

4 x M4 mounting hole
C6: 3.6
N7: 7.4

2 x M5 mounting hole (Fitting for the type with P/E


1
ports on the U and/or D sides)
(

7.1 88.2 L2 1.5

5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]
2 x G3/4 Applicable tube O.D.: ø8, ø5/16" Applicable tube O.D.: ø2
Conduit port : ø3.2, ø1/8"
(Station 1)---(Station n) : ø4, ø5/32"
: ø6, ø1/4"

1 P 1 P
77.7

13.6
10.6

63.1
56.6
45.5

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

13.2

(For DIN rail


mounting)
7.5

34.9
11.8

(Pitch)
107.1 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10T-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3 321.8 332.3 342.8 353.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5 375
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16

61
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/Terminal Block Box/Series SY5000

Replacement
U C4, N3
SS5Y5-10T- Stations D - C6, N7 (D)

Parts
B C8, N9

Metal Base
D side U side

Plug-in
DIN rail holding screw
(L5) L1 Manual override Note 2)
(For DIN rail mounting) DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail

Flat Ribbon Cable


4(A) port side: Blue (For rubber seal)

D-sub Connector
: Gray (For metal seal)
Light/surge

PC Wiring
2(B) port side: Yellow
voltage suppressor
D side

U side

EX510
8
BA BA BA BA BA

5.5
14 A 14 A 14 A 14 A 14 A

35
126.4

Terminal D-sub Connector Plug-in Connector


97.5

113.4

Connecting Base
80

81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B
16.4

Flat Ribbon Cable


1

Block Box PC Wiring


10.9
4.7
(5.9)
(8.3)

2 x M5 mounting hole
4 x M5 mounting hole
7.1 87.7 L2 1.5
(Fitting for the type with P/E
5.3 L4 ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)

Lead Wire
L3

Connector
Circular
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø10, ø3/8" [4(A), 2(B) port]

EX120 EX126 EX260 EX250 EX600 EX500


(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
2 x G3/4
: ø6, ø1/4"
Conduit port : ø8, ø5/16"
14.1
77.7

1 P 1 P
73.2
8.7

2 B2 B2 B2 B2 B
56.6
45.5

33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A
13.2

12.4

(For DIN rail


mounting)

34.9
7.5

11.8

(Pitch)
108.8 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10T-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Manifold
Options

L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 460.5 485.5 498
Specific Product

L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425 437.5 450 475 487.5
Precautions

L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5

62
Plug-in Connector Connecting Base
Terminal Block Box

SY3000/5000
Type 12
Top Ported
Series
How to Order Manifold

SS5Y 3 12T 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series Valve stations SUP/EXH block assembly


3 SY3000 Symbol Stations Note Nil Internal pilot
5 SY5000 02 2 stations S Internal pilot, Built-in silencer
Double wiring Note 1) R External pilot
10 10 stations ∗ For built-in silencer type, P and E ports are
02 2 stations available on U and D sides. 3/5(E) port is
Specified layout Note 2)
P, E port entry plugged. The silencer exhaust port is located
(Available up to 20 solenoids)
20 20 stations on the opposite side of P, E port entry.
U Note) U side (2 to 10 stations)
Note 1) Double wiring: 2-position single, double, 3- (Example: When the P, E port entry is D side,
D Note) D side (2 to 10 stations)
the silencer exhaust port is U side.)
B Both sides (2 to 20 stations) position and 4-position valves can be used
on all manifold stations. ∗ When the built-in silencer type is used, keep
Note) rFor type “S”, supply/exhaust block the exhaust port from coming in direct contact
Use of a 2-position single solenoid will
assembly with built-in silencer, choose U or with water or other liquids.
D for P port entry.
result in an unused control signal. If this is
not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-
P, E port size
position and 4-position valves cannot be
used where single wiring has been
(One-touch fittings)
specified.) Symbol SY3000 SY5000
Note 3) This also includes the number of blanking Nil ø8 ø10
plate assembly. N ø5/16" ø3/8"
∗ For N, sizes are in inches.

How to Order Manifold Assembly


Mounting
Nil Direct mounting
Example (SS5Y3-12T-쏔) DIN rail mounting
2-position double (24 VDC) D
(With DIN rail)
SY3230-5U1-C6 (1 set) DIN rail mounting
2-position single (24 VDC) 3-position closed D0
center (24 VDC)
(Without DIN rail)
SY3130-5U1-C6 (3 sets)
SY3330-5U1-C6 (1 set) D3 For 3 stations Specify a longer rail than
the standard length.
D20 For 20 stations

ide
Us
s
n
tio
ta
S
3
2
1

ide
Ds
Manifold base
(5 stations)
SS5Y3-12T-05D
SS5Y3-12T-05D ············ 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ············ 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ············ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ············ 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the
arrangement becomes complicated, specify on a manifold specification
sheet.

63
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Coil type C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center Nil Standard C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center ∗ Be sure to select the power saving circuit type
C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) long periods of time. One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Note the specified energizing time when power
Symbol A, B port SY3000 SY5000

Lead Wire
saving circuit is selected. Refer to page 154.
∗ Only rubber seal type is available for the N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage
N7 ø1/4" One-touch fitting 쎲 쎲

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
5 24 VDC
Seal type 6 12 VDC
0 Rubber seal

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
Light/surge voltage suppressor
Nil Rc
and common specification
F G
Nil Without light/surge voltage suppressor (Non-polar)
Pilot type N NPT
R With surge voltage suppressor (Non-polar)
Nil Internal pilot
T NPTF
U With light/surge voltage suppressor (Non-polar)
R External pilot ∗ Only Nil is available for M5.
S With surge voltage suppressor (Positive common)
Z With light/surge voltage suppressor (Positive common)
NS With surge voltage suppressor (Negative common)
Back pressure check valve Type of mounting screw
NZ With light/surge voltage suppressor (Negative common)
(Built-in valve type) Nil Round head combination screw
∗ Only “Z” and “NZ” types are available for the
Nil None B Hexagon socket head cap screw
product with power saving circuit.
H Built-in K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve !0 Manual override ∗ For “K” and “H”, the valve body cover has a
is required for a valve with metal seal. Refer Nil: Non-locking D: Push-turn F: Slide locking drop prevention construction to stop the
to page 147 for Ordering Example. However, mounting screws from falling out when the
push type locking slotted type
it is not recommended to use the built-in valve valve is removed for maintenance etc.
type
type and the manifold installed type at the ∗ When ordering a valve individually, the base
same time because it will reduce the flow. gasket is not included. Since the base gasket
∗ The built-in valve type back pressure check is attached to the manifold, please order the
valve is not available for the 3-position type. base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the
Part No.

individual SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
64
Series SY3000/5000

Terminal Block Connection

Step 1. Removing the terminal block cover Step 2. The below diagram shows the terminal block wiring.
Loosen the 4 mounting screws (M4) to remove the All stations are provided with double wiring
terminal block cover. regardless of the mounted valves.
Connect each wire to the power supply side, according
Terminal block cover to the markings provided inside the terminal block.
Mounting screw (M4)
M3 screw

Gasket

m
6m
Electrical entry
2 x G3/4

Step 3. Mounting the terminal block cover


Securely tighten the screws to the torque shown in the
below table only after confirming that the gasket is
installed correctly.
Proper tightening torque N·m • Applicable crimped terminal: 1.25-3S, 1.25Y-3, 1.25Y-3N, 1.25Y-3.5
0.7 to 1.2
• Name plate: VVQ5000-N-T
• Drip-proof plug assembly (for G3/4): AXT100-B06A

Electrical Wiring Specifications (IP67 compatible)


Standard wiring Specified Layout
Terminal no. Polarity
Mixed wiring of single and double wiring can
SOL.a be specified on the manifold specification
1A (–) (+)
Station 1 SOL.b sheet. The maximum number of stations is
1A

1B (–) (+)
1B
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

2A

SOL.a determined according to the number of


2B

2A (–) (+)
3A

Station 2 SOL.b solenoids. The total number of solenoids


3B

2B (–) (+)
4A

SOL.a should be 20 or less. 1 solenoid is required for


4B

3A (–) (+)
5A

Station 3 2-position single, and 2 solenoids for 2-


5B

SOL.b
3B (–) (+)
6A 7A

6B

SOL.a
4A (–) (+)
position double, 3-position and 4-position.
7B

Station 4 SOL.b
8A

4B (–) (+)
8B

SOL.a
9A 10A COM

5A (–) (+)
9B 10B

Station 5 SOL.b
5B (–) (+)
SOL.a
6A (–) (+)
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

Station 6 SOL.b
6B (–) (+)
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

SOL.a
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7A (–) (+)
Station 7 SOL.b
7B (–) (+)
SOL.a
If alignment is not specified, the 8A (–) (+)
internal wiring is double wiring Station 8 SOL.b
8B (–) (+)
(connected to SOL. a and SOL. b) SOL.a
9A (–) (+)
regardless of number of stations, Station 9 SOL.b
9B (–) (+)
valve and option types. SOL.a
10A (–) (+)
Station 10 SOL.b
10B (–) (+)
Note) When using a valve with COM. (+) (–)
no polarity, either positive
Positive Negative
common or negative common common
common can be used.

65
Plug-in Connector Connecting Base
Type 10
Side Ported Lead Wire

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 10 L1 1 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series Number of cores Valve stations


3 SY3000 (Lead wire) (L1쏔) (L3쏔)
5 SY5000 L1 34 cores Symbol Stations Note Symbol Stations Note
L2 17 cores 02 2 stations 02 2 stations
L3 9 cores Double wiring Note 1) Double wiring Note 1)
16 16 stations 04 4 stations
02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
Type Lead wire length
(Available up to (Available up to
10 Side ported 1 0.6 m 32 solenoids) 8 solenoids)
24 24 stations 08 8 stations
11 Bottom ported∗ 2 1.5 m
∗ The SY5000 manifold base is 3 3m (L2쏔)
used for the bottom ported of Symbol Stations Note
the SY3000. When ordering, 02 2 stations
refer to Plug-in Mixed Mounting Double wiring Note 1)
Type Manifold (from page 127). 08 8 stations
02 2 stations Specified layout Note 2)
(Available up to
16 16 stations 16 solenoids)
Note 1) Double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the manifold
How to Order Manifold Assembly specification sheet. (Note that 2-position double, 3-position and 4-
position valves cannot be used where single wiring has been
specified.)
Example (SS5Y3-10L11-쏔) Note 3) This also includes the number of blanking plate assembly.
2-position double (24 VDC)
SY3200-5U1 (1 set) P, E port entry
2-position single (24 VDC)
SY3100-5U1 (3 sets) 3-position closed U U side (2 to 10 stations)
center (24 VDC) D D side (2 to 10 stations)
SY3300-5U1 (1 set) B Both sides (2 to 24 stations)

SUP/EXH block assembly


Nil Internal pilot
S Internal pilot, Built-in silencer
R External pilot
e ∗ 3/5(E) port is plugged for the built-in silencer type.
U sid
ns ∗ When the built-in silencer type is used, keep the exhaust port from
io
Stat coming in direct contact with water or other liquids.
3
2 Refer to the page on the right for .
1
e
D sid

Manifold base
o Mounting and Option
(5 stations) Symbol Mounting Option
SS5Y3-10L11-05D-C6 None
Direct
Name plate (With station number)
SS5Y3-10L11-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) mounting
Name plate (Without station number)
∗SY3100-5U1··················· 3 sets (2-position single part no.)
∗SY3200-5U1··················· 1 set (2-position double part no.)
Without name plate
DIN rail
∗SY3300-5U1··················· 1 set (3-position closed center part no.) Name plate (With station number)
mounting
Name plate (Without station number)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc. Note 1) Enter the number of stations inside 첸. (Refer to “DIN Rail Option”
below.)
• The valve arrangement is numbered as the 1st station from the D side. Note 2) Only direct mounting is available for Type 11 (Bottom ported).
• Under the manifold part number, state the valves to be mounted in order
DIN Rail Option
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet. Nil Direct mounting
0 Without DIN rail (with bracket)
Note) When mixing top ported configurations, select from page 72.
3 For 3 stations
In this case, use caution as there is also output on the A and B port on base side. Specify a longer rail than the
Specify on a manifold specification sheet if plugs are required on the A and B total length of specified stations.
port on base side. 24 For 24 stations
67
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
Symbol A, B port Symbol A, B port

Flat Ribbon Cable


D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow Note)
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow Note)

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —


B6 쎲 쎲 BN9 쎲

Flat Ribbon Cable


ø6 One-touch fitting — ø5/16" One-touch fitting — —
B8 ø8 One-touch fitting — 쎲 — LM∗
Elbow port, mixed sizes

Block Box PC Wiring


(Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting

Lead Wire
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000
Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
4 3-position exhaust center pressure type.
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.)
B∗ 4-position dual 3-port valve (N.O./N.O.)
Nil Standard
C∗ 4-position dual 3-port valve (N.C./N.O.)
T With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal is available for the 4-position dual 3-port valve.
when the valve is continuously energized for
long periods of time. Type of mounting screw
Seal type
∗ Note the specified energizing time when power Nil Round head combination screw
0 Rubber seal saving circuit is selected. Refer to page 154. B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot 6 12 VDC drop prevention construction to stop the
R External pilot
mounting screws from falling out when the
Light/surge voltage suppressor
and Plug Assembly/

valve is removed for maintenance etc.


One-touch Fittings

Back pressure check valve and common specification ∗ When ordering a valve individually, the base
(Built-in valve type) Nil gasket is not included. Since the base gasket
Part No.

Without light/surge voltage suppressor (Non-polar)


Nil None R With surge voltage suppressor (Non-polar) is attached to the manifold, please order the
H Built-in base gasket separately if it is needed for
U With light/surge voltage suppressor (Non-polar)
Manifold

maintenance service.
Options

∗ Only rubber seal type. Manifold installed type S With surge voltage suppressor (Positive common) Refer to page 136 for part numbers of the
is available if the back pressure check valve Z With light/surge voltage suppressor (Positive common) base gasket and mounting screw.
is required for a valve with metal seal. Refer
NS With surge voltage suppressor (Negative common) ∗ "B" and "H" cannot be selected for the
to page 147 for Ordering Example. However,
NZ With light/surge voltage suppressor (Negative common) individual SUP/EXH spacer assembly or double
it is not recommended to use the built-in valve
Specific Product

check spacer assembly with residual pressure


type and the manifold installed type at the ∗ Only “Z” and “NZ” types are available for the
Precautions

release valve.
same time because it will reduce the flow. product with power saving circuit.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type.
68
Series SY3000/5000

Dimensions: Type 10/Lead Wire/Series SY3000


C2
1 U
SS5Y3-10L 2 쏔- Stations D - C3, N1
C4, N3 (D)
3 B C6, N7
D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
DIN rail Light/surge : Gray (For metal seal)
voltage suppressor 2(B) port side: Yellow

5.5
8
B A B A B A B A B A

92.6
14 A 14 A 14 A 14 A 14 A

35

83
67.8

60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B
17

4.6
1.7
)C6: 3.6
N7: 7.4
(4.9)
4 x M4 mounting hole
18 ( (Fitting for the type with P/E
ports on the U and/or D sides)
43 L2 1.5
(Lead wire length)

L4
0.6 m, 1.5 m, 3 m

18 5.3
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: ø2
[1(P), 3/5(E) port] (Station 1)---(Station n) : ø3.2, ø1/8"
Applicable tube O.D.: ø8, ø5/16" : ø4, ø5/32"
: ø6, ø1/4"
1 P 1 P
13.6
10.6

63.1
56.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
7.5

(Pitch)
11.8

54.8 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10L1쏔-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

69
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/Lead Wire/Series SY5000

Replacement
1 U C4, N3
SS5Y5-10L 2 쏔- Stations D - C6, N7 (D)

Parts
3 B C8, N9
D side U side
Manual override Note 2)

Metal Base
(L5) L1
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
DIN rail Light/surge : Gray (For metal seal)
voltage suppressor 2(B) port side: Yellow

Flat Ribbon Cable


D-sub Connector

PC Wiring
5.5
8
BA BA BA BA BA

EX510
14 A 14 A 14 A 14 A 14 A

35

97.5
113.4
64.4

81.2
61.7

Terminal D-sub Connector Plug-in Connector


5.5

Connecting Base
12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
(5.9)
(8.3)

Flat Ribbon Cable


4 x M5 mounting hole
18

Block Box PC Wiring


(Fitting for the type with P/E
18
42.5 L2 1.5
ports on the U and/or D sides)
(Lead wire length)
0.6 m, 1.5 m, 3 m

5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

Lead Wire
One-touch fitting
[4(A), 2(B) port]

Connector
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"

Circular
: ø6, ø1/4"
One-touch fitting
: ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

EX120 EX126 EX260 EX250 EX600 EX500


14.1

1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
8.7
33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A
12.4

(For DIN rail


mounting)

(Pitch)
7.5

11.8

56.5 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10L1쏔-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold
Options

L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
Specific Product

L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
Precautions

L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

70
Plug-in Connector Connecting Base
Lead Wire

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12 L1 1 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series Valve stations


3 SY3000 (L1쏔) (L3쏔)
5 SY5000 Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring Note 1) Double wiring Note 1)
Number of cores Lead wire length 16 16 stations 04 4 stations
(Lead wire) 1 0.6 m 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
L1 34 cores 2 1.5 m (Available up to (Available up to
L2 17 cores 3 3m 24 24 stations 32 solenoids) 08 8 stations 8 solenoids)
L3 9 cores
(L2쏔)
Symbol Stations Note

P, E port entry 02 2 stations


Double wiring Note 1)
U Note) U side (2 to 10 stations)
08 8 stations
D Note) D side (2 to 10 stations)
02 2 stations Specified layout Note 2)
B Both sides (2 to 24 stations)
(Available up to
Note) y For type “S”, supply/exhaust block 16 16 stations 16 solenoids)
assembly with built-in silencer, choose U or
D for P port entry. Note 1) Double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the manifold
specification sheet. (Note that 2-position double, 3-position and 4-
position valves cannot be used where single wiring has been
How to Order Manifold Assembly specified.)
Note 3) This also includes the number of blanking plate assembly.

Example (SS5Y3-12L11-쏔)
2-position double (24 VDC) SUP/EXH block assembly
SY3230-5U1-C6 (1 set)
2-position single (24 VDC) Nil Internal pilot
3-position closed
SY3130-5U1-C6 (3 sets) S Internal pilot, Built-in silencer
center (24 VDC)
SY3330-5U1-C6 (1 set) R External pilot
∗ For built-in silencer type, P and E ports are available on U and D sides.
3/5(E) port is plugged. The silencer exhaust port is located on the
opposite side of P, E port entry. (Example: When the P, E port entry is D
side, the silencer exhaust port is U side.)
∗ When the built-in silencer type is used, keep the exhaust port from
coming in direct contact with water or other liquids.
e
U sid
s
on
ati
St P, E port size
3 (One-touch fittings)
2
1
e Symbol SY3000 SY5000
D sid
Manifold base Nil ø8 ø10
(5 stations) N ø5/16" ø3/8"
SS5Y3-12L11-05D ∗ For N, sizes are in inches.
SS5Y3-12L11-05D ··· 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.)
Mounting
∗SY3330-5U1-C6 ······· 1 set (3-position closed center part no.) Nil Direct mounting
The asterisk denotes the symbol for assembly. DIN rail mounting
D
Prefix it to the part nos. of the valve, etc. (With DIN rail)
DIN rail mounting
• The valve arrangement is numbered as the 1st station from the D side. D0
(Without DIN rail)
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement D3 For 3 stations Specify a longer rail than
becomes complicated, specify on a manifold specification sheet. the standard length.
D24 For 24 stations
71
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Coil type C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center Nil Standard C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center ∗ Be sure to select the power saving circuit type
C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) long periods of time. One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Note the specified energizing time when power
Symbol A, B port SY3000 SY5000

Lead Wire
saving circuit is selected. Refer to page 154.
∗ Only rubber seal type is available for the N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
N7 ø1/4" One-touch fitting 쎲 쎲
Rated voltage

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
5 24 VDC
Seal type 6 12 VDC
0 Rubber seal

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
Light/surge voltage suppressor
Nil Rc
and common specification
F G
Nil Without light/surge voltage suppressor (Non-polar) N NPT
Pilot type R With surge voltage suppressor (Non-polar)
Nil Internal pilot
T NPTF
U With light/surge voltage suppressor (Non-polar)
R External pilot ∗ Only Nil is available for M5.
S With surge voltage suppressor (Positive common)
Z With light/surge voltage suppressor (Positive common)
Back pressure check valve NS With surge voltage suppressor (Negative common)
NZ With light/surge voltage suppressor (Negative common) Type of mounting screw
(Built-in valve type)
∗ Only “Z” and “NZ” types are available for the Nil Round head combination screw
Nil None
product with power saving circuit. B Hexagon socket head cap screw
H Built-in
K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type
is available if the back pressure check valve !0 Manual override H Hexagon socket head cap screw (Falling-out-prevention type)
is required for a valve with metal seal. Refer ∗ For “K” and “H”, the valve body cover has a
Nil: Non-locking D: Push-turn F: Slide locking drop prevention construction to stop the
to page 147 for Ordering Example. However,
push type locking slotted type mounting screws from falling out when the
it is not recommended to use the built-in valve
type and the manifold installed type at the type valve is removed for maintenance etc.
same time because it will reduce the flow. ∗ When ordering a valve individually, the base
∗ The built-in valve type back pressure check gasket is not included. Since the base gasket
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the
Part No.

individual SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
72
Series SY3000/5000

Electrical Wiring Specifications


Lead wire Electrical characteristics
Item Property
If alignment is not specified, the internal Conductor resistance
34 cores Lead wire Ω/km, 20°C
143 or less
2
wiring is double wiring (connected to
0.18 mm x 34 cores
SOL. a and SOL. b) regardless of Voltage limit
number of stations, valve and option 2000
34 1 2
V, 1 minute, AC
33
11
3 types.
32 26 12 4 Insulation resistance
25 17 13 10 or more
31 21 18 5 MΩ/km, 20°C
30 24 14 6
20 19
29 23 15 7 Note) Cannot be used for movable wiring.
22 16
28 8 The minimum bending radius of the
27 10 9
Sheath O.D. cable is 55 mm.
Approx. ø8.8

Lead Printed mark


Lead wire no. Polarity wire (Both sides)
SOL.a color Type Color
1 (–) (+)
Station 1 SOL.b Red
2 (–) (+) Orange
SOL.a Black
3 (–) (+)
Station 2 SOL.b Light Red
4 (–) (+)
SOL.a gray Black
5 (–) (+)
Station 3 SOL.b Red
6 (–) (+) White
SOL.a Black
7 (–) (+)
Station 4 SOL.b Red
8 (–) (+) Yellow
SOL.a Black
9 (–) (+)
Station 5 SOL.b Red
10 (–) (+) Pink
SOL.a Black
11 (–) (+)
Station 6 SOL.b Red
12 (–) (+) Orange
SOL.a Black
13 (–) (+)
Station 7 SOL.b Light Red
14 (–) (+)
SOL.a gray Black
15 (–) (+)
Station 8 SOL.b Red
16 (–) (+) White
SOL.a (–) (+) Black
17
Station 9 SOL.b Red
18 (–) (+) Yellow
SOL.a 19 (–) (+) Black
Station 10 SOL.b Red
20 (–) (+) Pink
SOL.a 21 (–) (+) Black
Station 11 SOL.b Red
22 (–) (+) Orange
SOL.a Black
23 (–) (+)
Station 12 SOL.b Red
24 (–) (+) Light
SOL.a gray Black
25 (–) (+)
Station 13 SOL.b Red
26 (–) (+) White
SOL.a 27 (–) (+) Black
Station14 SOL.b Red
28 (–) (+) Yellow
SOL.a 29 (–) (+) Black
Station 15 SOL.b Red
30 (–) (+) Pink
SOL.a (–) (+) Black
31
Station 16 SOL.b Red
32 (–) (+) Orange
COM. 33 (+) (–) Black
COM. 34 (+) (–) Light Red
gray Black
Positive Negative
common common

Note) For negative common specification, a valve for negative


common or a valve without polarity should be used.

Specified Layout
Mixed wiring of single and double wiring can be specified on the
manifold specification. The maximum number of stations is
determined according to the number of solenoids. The total number
of solenoids should be 32 or less. 1 solenoid is required for 2-position
single, and 2 solenoids for 2-position double, 3-position and 4-
position.

73
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Electrical Wiring Specifications

Parts
Lead wire Electrical characteristics
Item Property

Metal Base
Conductor resistance
143 or less
17 cores Lead wire 9 cores Lead wire Ω/km, 20°C

Plug-in
0.18 mm2 x 17 cores 0.18 mm2 x 9 cores
Voltage limit
2000
1 V, 1 minute, AC
17 2
1
16 13 8 9 2 Insulation resistance
9 3 10 or more
MΩ/km, 20°C

Flat Ribbon Cable


8 5 3

D-sub Connector
15 12 10 4
11 7 4
14 5 6
Note) Cannot be used for movable wiring. Note) Cannot be used for movable wiring.

PC Wiring
7 6
The minimum bending radius of the The minimum bending radius of the
cable is 45 mm. cable is 40 mm.

EX510
Sheath O.D. Sheath O.D.
ø6.8 ø6.3
Lead Printed mark Lead Printed mark
Lead wire no. Polarity wire (Both sides) Lead wire no. Polarity wire (Both sides)
SOL.a color Type Color SOL.a color Type Color
1 (–) (+) 1 (–) (+)

Terminal D-sub Connector Plug-in Connector


Connecting Base
Station 1 SOL.b Red Station 1 SOL.b Red
2 (–) (+) Orange 2 (–) (+) Orange
SOL.a Black SOL.a Black
3 (–) (+) 3 (–) (+)
Station 2 SOL.b Light Red Station 2 SOL.b Light Red
4 (–) (+) 4 (–) (+)
SOL.a gray Black SOL.a gray Black
5 (–) (+) 5 (–) (+)
Station 3 SOL.b Red Station 3 SOL.b Red
6 (–) (+) White 6 (–) (+) White

Flat Ribbon Cable


SOL.a Black SOL.a Black
7 (–) (+) 7 (–) (+)
Station 4 Station 4

Block Box PC Wiring


SOL.b Red SOL.b Red
8 (–) (+) Yellow 8 (–) (+) Yellow
SOL.a Black COM. 9 Black
9 (–) (+) (+) (–)
Station 5 SOL.b Red Pink Red
10 (–) (+) Pink Positive Negative
SOL.a Black common common
11 (–) (+)
Station 6 SOL.b Red
12 (–) (+) Orange
SOL.a Black
13 (–) (+)

Lead Wire
Station 7 SOL.b Red
14 (–) (+) Light
SOL.a gray Black
15 (–) (+)
Station 8 SOL.b Red
16 (–) (+) White

Connector
COM. 17 Black
(+) (–)

Circular
Positive Negative
Yellow Red
common common

EX120 EX126 EX260 EX250 EX600 EX500


Note) For negative common specification, a valve for negative
common or a valve without polarity should be used.

and Plug Assembly/


One-touch Fittings

Part No.
Manifold
Options
Specific Product
Precautions

74
Plug-in Connector Connecting Base
Type 10
Side Ported Circular Connector

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 5 10 M 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series Valve stations P, E port entry


3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring Note 1) B Both sides (2 to 24 stations)
12 12 stations
02 2 stations
Specified layout Note 2)
Type (Available up to 24 solenoids)
10 Side ported 24 24 stations SUP/EXH block assembly
11 Bottom ported∗ Note 1) Double wiring: 2-position single, double, Nil Internal pilot
3-position and 4-position valves can be S Internal pilot, Built-in silencer
∗ The SY5000 manifold base is used for the
used on all manifold stations. R External pilot
bottom ported of the SY3000. When ordering,
Use of a 2-position single solenoid will
refer to Plug-in Mixed Mounting Type Manifold ∗ 3/5(E) port is plugged for the built-in silencer
result in an unused control signal. If this is
(from page 127). type.
not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring ∗ When the built-in silencer type is used, keep
specifications on the manifold the exhaust port from coming in direct contact
specification sheet. (Note that 2-position with water or other liquids.
double, 3-position and 4-position valves
cannot be used where single wiring has Refer to the page on the right for .
been specified.)
Note 3) This also includes the number of blanking
plate assembly.
u Mounting and Option
How to Order Manifold Assembly Symbol Mounting Option
None
Direct
Name plate (With station number)
Example (SS5Y3-10M-쏔) mounting
Name plate (Without station number)
2-position double (24 VDC) Without name plate
SY3200-5U1 (1 set) DIN rail
2-position single (24 VDC) Name plate (With station number)
3-position closed mounting
SY3100-5U1 (3 sets) Name plate (Without station number)
center (24 VDC)
SY3300-5U1 (1 set) Note 1) Enter the number of stations inside 첸.
(Refer to “DIN Rail Option” below.)
Note 2) Only direct mounting is available for
Type 11 (Bottom ported).

DIN Rail Option


Nil Direct mounting
ide 0 Without DIN rail (with bracket)
Us
ons 3 For 3 stations
ati Specify a longer rail than the
St
3 total length of specified stations.
2 24 For 24 stations
1
e
D sid
Manifold base
(5 stations)
SS5Y3-10M-05D-C6

SS5Y3-10M-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1 ··············· 3 sets (2-position single part no.)
∗SY3200-5U1 ··············· 1 set (2-position double part no.)
∗SY3300-5U1 ··············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 80.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
75
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported

Flat Ribbon Cable


A, B port A, B port

D-sub Connector
Symbol Symbol
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight

EX510
Straight

C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲


C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Terminal D-sub Connector Plug-in Connector


Downward Upward

Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow Note)
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow Note)

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —

Flat Ribbon Cable


B6 ø6 One-touch fitting 쎲 쎲 — BN9 ø5/16" One-touch fitting — 쎲 —

Block Box PC Wiring


B8 ø8 One-touch fitting — — LM∗
Elbow port, mixed sizes
쎲 쎲 —
(Including upward and downward piping)
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Lead Wire
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
Circular
SY 3 1 0 0 5 1

EX120 EX126 EX260 EX250 EX600 EX500


Series
3 SY3000 Base mounted
5 SY5000
Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
4 3-position exhaust center pressure type.
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.)
B∗ 4-position dual 3-port valve (N.O./N.O.)
Nil Standard
C∗ 4-position dual 3-port valve (N.C./N.O.)
T With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve.
when the valve is continuously energized for Type of mounting screw
Seal type long periods of time. Nil Round head combination screw
∗ Note the specified energizing time when
0 Rubber seal power saving circuit is selected. Refer to page B Hexagon socket head cap screw
1 Metal seal 154. K Round head combination screw (Falling-out-prevention type)
H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type Rated voltage
∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot 5 24 VDC drop prevention construction to stop the
R External pilot 6 12 VDC mounting screws from falling out when the
valve is removed for maintenance etc.
and Plug Assembly/
One-touch Fittings

Back pressure check valve Light/surge voltage suppressor ∗ When ordering a valve individually, the base
(Built-in valve type) and common specification gasket is not included. Since the base gasket
Part No.

is attached to the manifold, please order the


Nil None Nil Without light/surge voltage suppressor (Non-polar)
base gasket separately if it is needed for
H Built-in R With surge voltage suppressor (Non-polar) maintenance service.
Manifold
Options

∗ Only rubber seal type. Manifold installed type U With light/surge voltage suppressor (Non-polar) Refer to page 136 for part numbers of the
is available if the back pressure check valve S With surge voltage suppressor (Positive common) base gasket and mounting screw.
is required for a valve with metal seal. Refer Z With light/surge voltage suppressor (Positive common) ∗ "B" and "H" cannot be selected for the
to page 147 for Ordering Example. However, NS With surge voltage suppressor (Negative common) individual SUP/ EXH spacer assembly or
it is not recommended to use the built-in valve double check spacer assembly with residual
Specific Product

NZ With light/surge voltage suppressor (Negative common)


type and the manifold installed type at the pressure release valve.
Precautions

same time because it will reduce the flow. ∗ Only “Z” and “NZ” types are available for the
product with power saving circuit. Protective class
∗ The built-in valve type back pressure check
class (Mark: )
valve is not available for the 3-position type.
76
Series SY3000/5000

Dimensions: Type 10/Circular Connector/Series SY3000


C2
U
SS5Y3-10M- Stations D - C3, N1
C4, N3 (D)
B C6, N7
D side U side
(L5) L1 Manual override Note 2)

DIN rail holding screw (


Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
DIN rail Light/surge : Gray (For metal seal)
voltage suppressor 2(B) port side: Yellow

5.5
8
B A B A B A B A B A

92.6
14 A 14 A 14 A 14 A 14 A

35

83
67.8

60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B
21.9

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)

4 x M4 mounting hole
18
(Fitting for the type with P/E ports on the U and/or D sides)
(
18
43 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] (Station 1)---(Station n) Applicable tube O.D.: ø2
Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
: ø4, ø5/32"
Circular connector cable assembly : ø6, ø1/4"
1 P 1 P
AXT100-MC26-015: 1.5 m 63.1
AXT100-MC26-030: 3 m
13.6
10.6

56.6

AXT100-MC26-050: 5 m 3/5 E 2 B2 B2 B2 B2 B 3/5 E


40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail

Circular connector (26 pins)


mounting)
7.5

(Pitch)
11.8

made by CONINVERS GmbH 54.8 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10M-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

77
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/Circular Connector/Series SY5000

Replacement
U C4, N3
SS5Y5-10M- Stations D - C6, N7 (D)

Parts
B C8, N9 D side U side
Manual override Note 2)
(L5) L1
(Push-turn locking slotted type:
)

Metal Base
DIN rail holding screw Press, then rotate it.

Plug-in
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Gray (For metal seal)
2(B) port side: Yellow

Flat Ribbon Cable


D-sub Connector
5.5
8

PC Wiring
BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A

35

EX510
97.5
113.4
64.4

81.2
61.7
5.5

Terminal D-sub Connector Plug-in Connector


12 B 12 B 12 B 12 B 12 B

Connecting Base
24.2

10.9
4.7
18 (5.9)
(8.3)

Flat Ribbon Cable


18 4 x M5 mounting hole
L2 1.5

Block Box PC Wiring


42.5 (Fitting for the type with P/E
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Circular connector cable assembly L3
AXT100-MC26-015: 1.5 m
AXT100-MC26-030: 3 m

Lead Wire
AXT100-MC26-050: 5 m
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
(Station 1)----------- (Station n)

Connector
: ø6, ø1/4"

Circular
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

EX120 EX126 EX260 EX250 EX600 EX500


14.1

1 P 1 P 73.2
2 B2 B2 B2 B2 B
56.6
12.4

8.7

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
(For DIN rail
mounting)

Circular connector (26 pins)


7.5

(Pitch)
11.8

made by CONINVERS GmbH 56.5 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10M-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold
Options

L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
Specific Product

L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
Precautions

L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

78
Plug-in Connector Connecting Base
Circular Connector

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12M 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series Valve stations P, E port entry


3 SY3000 Symbol Stations Note U Note) U side (2 to 10 stations)
5 SY5000 02 2 stations D Note) D side (2 to 10 stations)
Double wiring Note 1) B Both sides (2 to 24 stations)
12 12 stations Note) rFor type “S”, supply/exhaust block
02 2 stations assembly with built-in silencer, choose U
Specified layout Note 2) or D for P port entry.
(Available up to 24 solenoids)
24 24 stations
Note 1) Double wiring: 2-position single, double, 3-
position and 4-position valves can be used
on all manifold stations. SUP/EXH block assembly
Use of a 2-position single solenoid will Nil Internal pilot
result in an unused control signal. If this is S Internal pilot, Built-in silencer
not desired, order with a specified layout. R External pilot
Note 2) Specified layout: Indicate the wiring
∗ For built-in silencer type, P and E ports are
specifications on the manifold specification
available on U and D sides. 3/5(E) port is
sheet. (Note that 2-position double, 3-
plugged. The silencer exhaust port is located
position and 4-position valves cannot be
on the opposite side of P, E port entry.
used where single wiring has been
(Example: When the P, E port entry is D side,
specified.)
the silencer exhaust port is U side.)
Note 3) This also includes the number of blanking
∗ When the built-in silencer type is used, keep
plate assembly.
the exhaust port from coming in direct contact
with water or other liquids.

How to Order Manifold Assembly


P, E port size
Example (SS5Y3-12M-쏔) (One-touch fittings)
2-position double (24 VDC) Symbol SY3000 SY5000
2-position single (24 VDC) SY3230-5U1-C6 (1 set) Nil ø8 ø10
SY3130-5U1-C6 (3 sets)
3-position closed N ø5/16" ø3/8"
center (24 VDC)
∗ For N, sizes are in inches.
SY3330-5U1-C6 (1 set)

Mounting
Nil Direct mounting
DIN rail mounting
ide D
Us (With DIN rail)
s
on
ati DIN rail mounting
St D0
3 (Without DIN rail)
2
1 D3 For 3 stations Specify a longer rail than
ide
Ds the standard length.
D24 For 24 stations
Manifold base (5 stations)
SS5Y3-12M-05D

SS5Y3-12M-05D ········ 1 set (Type 12 5-station manifold base part no.)


∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ········ 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

79
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Coil type C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center Nil Standard C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center ∗ Be sure to select the power saving circuit type
C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) long periods of time. One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Note the specified energizing time when Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal is available for the power saving circuit is selected. Refer to page
N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. 154.
N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage N7 ø1/4" One-touch fitting 쎲 쎲

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
5 24 VDC
Seal type 6 12 VDC
0 Rubber seal

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
Light/surge voltage suppressor
and common specification Nil Rc
Nil Without light/surge voltage suppressor (Non-polar) F G
Pilot type R With surge voltage suppressor (Non-polar) N NPT
Nil Internal pilot U With light/surge voltage suppressor (Non-polar) T NPTF
R External pilot S With surge voltage suppressor (Positive common) ∗ Only Nil is available for M5.
Z With light/surge voltage suppressor (Positive common)
NS With surge voltage suppressor (Negative common)
Back pressure check valve NZ With light/surge voltage suppressor (Negative common) Type of mounting screw
(Built-in valve type)
∗ Only “Z” and “NZ” types are available for the Nil Round head combination screw
Nil None product with power saving circuit. B Hexagon socket head cap screw
H Built-in
K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve Manual override
is required for a valve with metal seal. Refer ∗ For “K” and “H”, the valve body cover has a
Nil: D: F:
to page 147 for Ordering Example. However, drop prevention construction to stop the
Non-locking Push-turn Slide locking
it is not recommended to use the built-in valve mounting screws from falling out when the
push type locking type
type and the manifold installed type at the valve is removed for maintenance etc.
slotted
same time because it will reduce the flow. ∗ When ordering a valve individually, the base
type
∗ The built-in valve type back pressure check gasket is not included. Since the base gasket
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the
Part No.

individual SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

80
Series SY3000/5000

Electrical Wiring Specifications Cable Assembly


015
Circular connector
AXT100-MC26- 030
If alignment is not specified, the 050
internal wiring is double wiring Cable
!5 q 0.3 mm2 x 26 cores
!4 !6 w (connected to SOL. a and SOL.
b) regardless of number of O.D. ø1.4 Lead wire color for circular
!3 @4 !7 e
stations, valve and option types. connector cable assembly
!2 @3 @5 !8 r
Approx. ø10 by terminal number
!1 @2 @6 !9 t Lead Dot
!0 @1 @0 y
Terminal
Seal (Length) wire
no. color marking
o i u
015 1
2
3
Black
Brown
Red
None
None
None
4 Orange None
Terminal Polarity 5 Yellow None
no. 6 Pink None
SOL.a (–) (+)
1
Station 1 SOL.b 7 Blue None
2 (–) (+)
8 Purple White

L
SOL.a (–) (+)
3
Station 2 SOL.b 9 Gray Black
4 (–) (+)
SOL.a (–) (+)
10 White Black
5

60
Station 3 SOL.b (–) (+) 11 White Red
6
SOL.a (–) (+) 12 Yellow Red
7
Station 4 SOL.b (–) (+) 13 Orange Red
8 Plug
SOL.a 9 (–) (+) 14 Yellow Black
Station 5 SOL.b (–) (+) 15 Pink Black
10
SOL.a 11 (–) (+) 16 Blue White
Station 6 SOL.b (–) (+) 17 Purple None
12
SOL.a (–) (+) 18 Gray None
13
Station 7 SOL.b (–) (+) 19 Orange Black
14
SOL.a
ø30
15 (–) (+) 20 Red White
Station 8 SOL.b (–) (+)
16 21 Brown White
SOL.a 15 1
17 (–) (+) 14 2 Terminal no. 22 Pink Red
16
Station 9 SOL.b (–) (+) 24 17
18 13 25 3 23 Gray Red
SOL.a 19 (–) (+) 23 18
12 4 24 Black White
Station 10 SOL.b (–) (+) 26
20 22 19 25 White None
SOL.a (–) (+) 11 21 20 5
21 26 White None
Station 11 SOL.b (–) (+) 10 6
22 M27 female
SOL.a 9 8 7
23 (–) (+) thread
Station 12 SOL.b (–) (+)
Electrical characteristics
24
Item Property
COM. 25 (+) (–) Conductor
COM. 26 (+) (–) 65 or
resistance
less
Ω/km, 20°C
Positive Negative
common common Voltage limit
1000
V, 1 minute, AC
Circular connector cable assembly
Insulation
Cable Assembly part no. 5 or
resistance
length (L) 26 pins more
MΩ/km, 20°C
Note) When using a valve with no polarity, either positive common or 1.5 m AXT100-MC26-015
Note) The minimum
negative common can be used. 3m AXT100-MC26-030 bending
5m AXT100-MC26-050 radius of the
∗ Cannot be used for movable wiring. circular
∗ Lengths other than the above is also connector
Specified Layout available. Please contact SMC for details. cable is 20
mm.
Mixed wiring of single and double wiring can be specified on the
manifold specification sheet. The maximum number of stations is
determined according to the number of solenoids. The total number
of solenoids should be 24 or less. 1 solenoid is required for 2-position
single, and 2 solenoids for 2-position double, 3-position and 4-
position.

81
Plug-in Connector Connecting Base
Type 10
Side Ported EX500

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 10 S A2 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series SI unit Valve stations


3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 DeviceNet™/PROFIBUS DP/ 02 2 stations
A2 CC-Link/EtherNet/IP™ Double wiring Note 1)
(Positive common) 08 8 stations
Type DeviceNet™/PROFIBUS DP/ 02 2 stations
10 Side ported Specified layout Note 2)
A2N CC-Link/EtherNet/IP™
(Available up to 16 solenoids)
11 Bottom ported∗ (Negative common) 16 16 stations
∗ The SY5000 manifold base is used for the Note) Ensure that the valve's common Note 1) Double wiring: 2-position single,
bottom ported of the SY3000. When ordering, specifications match. double, 3-position and 4-position valves
refer to Plug-in Mixed Mounting Type Manifold can be used on all manifold stations.
(from page 127). Use of a 2-position single solenoid will
SUP/EXH block assembly result in an unused control signal. If this
is not desired, order with a specified
P, E port entry Nil Internal pilot
layout.
U U side (2 to 10 stations) S Internal pilot, Built-in silencer Note 2) Specified layout: Indicate the wiring
D D side (2 to 10 stations) R External pilot specifications on the manifold
B Both sides (2 to 16 stations) ∗ 3/5(E) port is plugged for the built-in silencer specification sheet. (Note that 2-
type. position double, 3-position and 4-
∗ When the built-in silencer type is used, keep position valves cannot be used where
the exhaust port from coming in direct contact single wiring has been specified.)
with water or other liquids. Note 3) This also includes the number of
blanking plate assembly.
How to Order Manifold Assembly Note 4) For the product without the SI unit (S0),
note the maximum number of solenoids
of the SI unit that will be mounted. If the
Example (SS5Y3-10SA2-쏔) layout is specified, indicate it on the
2-position double (24 VDC) manifold specification sheet.
2-position single (24 VDC) SY3200-5U1 (1 set)
SY3100-5U1 (3 sets)
3-position closed Refer to the page on the right for .
center (24 VDC)
SY3300-5U1 (1 set)
i Mounting and Option
Symbol Mounting Option
None
Direct
Name plate (With station number)
mounting
Name plate (Without station number)
ide
Us DIN rail
Without name plate
Name plate (With station number)
s
n

mounting
tio
ta

Name plate (Without station number)


S

3 Note 1) Enter the number of stations inside 첸.


2
1 (Refer to “DIN Rail Option” below.)
ide
Ds Note 2) Only direct mounting is available for
Manifold base (5 stations) Type 11 (Bottom ported).
SS5Y3-10SA2-05D-C6 DIN Rail Option
Nil Direct mounting
SS5Y3-10SA2-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)
0 Without DIN rail (with bracket)
∗SY3100-5U1···················· 3 sets (2-position single part no.)
∗SY3200-5U1···················· 1 set (2-position double part no.)
3 For 3 stations
Specify a longer rail than the
∗SY3300-5U1···················· 1 set (3-position closed center part no.) total length of specified stations.
16 For 16 stations
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc. ∗ If the DIN rail must be mounted without an SI
unit, select D0. Then, refer to L3 of the
• The valve arrangement is numbered as the 1st station from the D side. dimensions for the DIN rail length and order
• Under the manifold part number, state the valves to be mounted in order separately. (Refer to page 140 for the DIN rail
from the 1st station as shown in the figure above. If the arrangement part number.)
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 88.
Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
In this case, use caution as there is also output on the A and B port on base side.
Electric Products (CAT.E150) for details on the EX500 Gateway-
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
type Serial Transmission System.

83
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
A, B port A, B port

Flat Ribbon Cable


Symbol Symbol

D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow Note)
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow Note)

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —

Flat Ribbon Cable


B6 ø6 One-touch fitting 쎲 쎲 — BN9 ø5/16" One-touch fitting — 쎲 —
B8 ø8 One-touch fitting — 쎲 — Elbow port, mixed sizes

Block Box PC Wiring


LM∗ (Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Lead Wire
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000 Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa)
Nil: D: F:
B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
1 2-position single
K∗ High pressure type (1.0 MPa) push type locking type
2 2-position double
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
pressure type.
4 3-position exhaust center
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.) Nil Standard
B∗ 4-position dual 3-port valve (N.O./N.O.) T With power saving circuit (Continuous duty type)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4- when the valve is continuously energized for
position dual 3-port valve. long periods of time. Type of mounting screw
∗ Note the specified energizing time when power Nil
Seal type Round head combination screw
saving circuit is selected. Refer to page 154.
B Hexagon socket head cap screw
0 Rubber seal
K Round head combination screw (Falling-out-prevention type)
1 Metal seal Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type 5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot drop prevention construction to stop the
Light/surge voltage suppressor mounting screws from falling out when the
R External pilot
and Plug Assembly/

and common specification valve is removed for maintenance etc.


One-touch Fittings

R With surge voltage suppressor (Non-polar) ∗ When ordering a valve individually, the base
Back pressure check valve gasket is not included. Since the base gasket
Part No.

(Built-in valve type) U With light/surge voltage suppressor (Non-polar)


is attached to the manifold, please order the
Nil None S With surge voltage suppressor (Positive common) base gasket separately if it is needed for
Z With light/surge voltage suppressor (Positive common)
Manifold

H maintenance service.
Options

Built-in
NS With surge voltage suppressor (Negative common) Refer to page 136 for part numbers of the
∗ Only rubber seal type. Manifold installed type
NZ With light/surge voltage suppressor (Negative common) base gasket and mounting screw.
is available if the back pressure check valve
∗ Only “Z” and “NZ” types are available for the ∗ "B" and "H" cannot be selected for the
is required for a valve with metal seal. Refer
product with power saving circuit. Select a individual SUP/EXH spacer assembly or double
to page 147 for Ordering Example. However,
Specific Product

valve from R, U, S or Z when the SI unit check spacer assembly with residual pressure
it is not recommended to use the built-in valve
Precautions

specification is A2 (Positive common). Select release valve.


type and the manifold installed type at the
a valve from R, U, NS or NZ when the SI unit Protective class
same time because it will reduce the flow.
specification is A2N (Negative common). class (Mark: )
∗ The built-in valve type back pressure check
valve is not available for the 3-position type. 84
Series SY3000/5000

Dimensions: Type 10/EX500/Series SY3000


C2
U
SS5Y3-10SA2- Stations D - C3, N1
C4, N3 (D)
B C6, N7

D side U side
Manual override Note 2)

DIN rail holding screw


(For DIN rail mounting)
(L5) L1
(Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
Light/surge voltage suppressor 2(B) port side: Yellow
SI unit

5.5
8
B A B A B A B A B A

92.6
14 A 14 A 14 A 14 A 14 A

35

83
67.8

60.5
40.9
12 B 12 B 12 B 12 B 12 B

4.6

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
12.1

4 x M4 mounting hole
(Fitting for the type with P/E ports on the U and/or D sides)
(

34.5 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø8, ø5/16" [4(A), 2(B) port]
(Station 1)---(Station n) Applicable tube O.D.: ø2
M12 : ø3.2, ø1/8"
8-pin socket : ø4, ø5/32"
: ø6, ø1/4"
0
1 P 1 P
10.6
13.6

63.1
56.6

1
60
43.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
22.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail

M12
mounting)
7.5

17.5 (Pitch)
8-pin plug
11.8

46.3 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10SA2-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.5 114 124.5 135 145.5 156 166.5 177 187.5 198 208.5 219 229.5 240 250.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5

85
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/EX500/Series SY5000

Replacement
U C4, N3
SS5Y5-10SA2- Stations D - C6, N7 (D)

Parts
B C8, N9

Metal Base
D side U side
Manual override Note 2)

Plug-in
(L5) L1
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
Light/surge voltage suppressor : Gray (For metal seal)

Flat Ribbon Cable


D-sub Connector
SI unit 2(B) port side: Yellow

PC Wiring
DIN rail
8

EX510
5.5
BA BA BA BA BA

35
14 A 14 A 14 A 14 A 14 A

97.5
113.4
79.9

Terminal D-sub Connector Plug-in Connector


Connecting Base
81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B

10.9
8.7

Flat Ribbon Cable


(5.9)

4.7
(8.3)

Block Box PC Wiring


4 x M5 mounting hole

34 L2 1.5
(Fitting for the type with P/E
5.3 L4 ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
L3

Lead Wire
Connector
One-touch fitting

Circular
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø10, ø3/8" (Station 1)----------- (Station n) : ø6, ø1/4"

EX120 EX126 EX260 EX250 EX600 EX500


: ø8, ø5/16"
M12
8-pin socket
0
14.1

1 P 1 P
73.2

2 B2 B2 B2 B2 B
56.6

1
60
43.2
33.4

3/5 E 3/5 E
29.1
22.2

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


mounting)
7.5

17.5
11.8

M12 (Pitch)
48 18 P = 16 (20.5)
8-pin plug

Note 1) These figures show the “SS5Y5-10SA2-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Manifold
Options

L1 120.5 136.5 152.5 168.5 184.5 200.5 216.5 232.5 248.5 264.5 280.5 296.5 312.5 328.5 344.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
Specific Product

L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
Precautions

L5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 18 16 14.5

86
Plug-in Connector Connecting Base
EX500

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12S A2 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series P, E port entry Valve stations


3 SY3000 U Note) U side (2 to 10 stations) Symbol Stations Note
5 SY5000 D Note) D side (2 to 10 stations) 02 2 stations
B Both sides (2 to 16 stations) Double wiring Note 1)
Note) tFor type “S”, supply/exhaust block 08 8 stations
SI unit assembly with built-in silencer, choose U 02 2 stations
Specified layout Note 2)
or D for P port entry.
0 Without SI unit (Available up to 16 solenoids)
16 16 stations
DeviceNet™/PROFIBUS DP/
A2 CC-Link/EtherNet/IP™ Note 1) Double wiring: 2-position single, double,
(Positive common) SUP/EXH block assembly 3-position and 4-position valves can be
used on all manifold stations.
DeviceNet™/PROFIBUS DP/ Nil Internal pilot
Use of a 2-position single solenoid will
A2N CC-Link/EtherNet/IP™ S Internal pilot/Built-in silencer
result in an unused control signal. If this
(Negative common) R External pilot is not desired, order with a specified
Note) Ensure that the valve's common ∗ For built-in silencer type, P and E ports are layout.
specifications match. available on U and D sides. 3/5(E) port is Note 2) Specified layout: Indicate the wiring
plugged. The silencer exhaust port is located specifications on the manifold
on the opposite side of P, E port entry. specification sheet. (Note that 2-
(Example: When the P, E port entry is D side, position double, 3-position and 4-
the silencer exhaust port is U side.) position valves cannot be used where
∗ When the built-in silencer type is used, keep single wiring has been specified.)
the exhaust port from coming in direct contact Note 3) This also includes the number of
with water or other liquids. blanking plate assembly.
Note 4) For the product without the SI unit (S0),
note the maximum number of solenoids
of the SI unit that will be mounted. If the
How to Order Manifold Assembly layout is specified, indicate it on the
manifold specification sheet.

Example (SS5Y3-12SA2-쏔)
2-position double (24 VDC) P, E port size
SY3230-5U1-C6 (1 set)
2-position single (24 VDC) (One-touch fittings)
SY3130-5U1-C6 (3 sets) 3-position closed Symbol SY3000 SY5000
center (24 VDC) Nil ø8 ø10
SY3330-5U1-C6 (1 set) N ø5/16" ø3/8"
∗ For N, sizes are in inches.

Mounting
e Nil Direct mounting
U sid
DIN rail mounting
D
s
n
tio

(With DIN rail)


ta
S

3 DIN rail mounting


2 D0
1 (Without DIN rail)
ide D3 For 3 stations
Manifold base Ds Specify a longer rail than
(5 stations) the standard length.
SS5Y3-12SA2-05D D16 For 16 stations
∗ When mounted on the DIN rail without the SI
SS5Y3-12SA2-05D ··· 1 set (Type 12 5-station manifold base part no.) unit, please select D0 and refer to L3 of the
∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.) dimensions for the DIN rail length, then order
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.) separately. (Refer to page 140 for the DIN rail
∗SY3330-5U1-C6 ········ 1 set (3-position closed center part no.) part number.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
becomes complicated, specify on a manifold specification sheet. Electric Products (CAT.E150) for details on the EX500 Gateway-
type Serial Transmission System.

87
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Coil type C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center Nil Standard C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center ∗ Be sure to select the power saving circuit type
C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) long periods of time. One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Note the specified energizing time when Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the power saving circuit is selected. Refer to page 쎲
N1 ø1/8" One-touch fitting —
4-position dual 3-port valve. 154.
N3 ø5/32" One-touch fitting 쎲 쎲
N7 ø1/4" One-touch fitting 쎲 쎲

Connector
Rated voltage N9 ø5/16" One-touch fitting — 쎲

Circular
Seal type 5 24 VDC
0 Rubber seal

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
Light/surge voltage suppressor Nil Rc
and common specification F G
Pilot type R With surge voltage suppressor (Non-polar) N NPT
Nil Internal pilot U With light/surge voltage suppressor (Non-polar) T NPTF
R External pilot S With surge voltage suppressor (Positive common) ∗ Only Nil is available for M5.
Z With light/surge voltage suppressor (Positive common)
NS With surge voltage suppressor (Negative common)
Back pressure check valve NZ Without light/surge voltage suppressor (Negative common) Type of mounting screw
(Built-in valve type) ∗ Only “Z” and “NZ” types are available for the Nil Round head combination screw
Nil None product with power saving circuit. Select a B Hexagon socket head cap screw
H Built-in valve from R, U, S or Z when the SI unit
specification is A2 (Positive common). Select K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type a valve from R, U, NS or NZ when the SI unit H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve specification is A2N (Negative common). ∗ For “K” and “H”, the valve body cover has a
is required for a valve with metal seal. Refer
drop prevention construction to stop the
to page 147 for Ordering Example. However,
mounting screws from falling out when the
it is not recommended to use the built-in valve
type and the manifold installed type at the !0 Manual override valve is removed for maintenance etc.
∗ When ordering a valve individually, the base
same time because it will reduce the flow. Nil: Non-locking D: Push-turn F: Slide locking gasket is not included. Since the base gasket
∗ The built-in valve type back pressure check push type locking slotted type is attached to the manifold, please order the
valve is not available for the 3-position type. type base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the
Part No.

individual SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

Protective class
class (Mark: )
88
Plug-in Connector Connecting Base
Type 10
Side Ported EX600

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 10 S6 Q 2 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series SI unit output polarity, end plate type Valve stations


3 SY3000 Power supply Power supply Symbol Stations Note
SI unit output polarity with M12 with 7/8 inch
5 SY5000 connector connector 02 2 stations
Without SI unit Nil Double wiring Note 1)
Type SI unit positive common 2 3 16 16 stations
10 Side ported SI unit negative common 4 5 02 2 stations
11 Bottom ported∗ Specified layout Note 2)
Note 1) Ensure a match with the common (Available up to 32 solenoids)
∗ The SY5000 manifold base is used for the 24 24 stations
specifications of the value to be used.
bottom ported of the SY3000. When ordering, Note 1) Double wiring: 2-position single,
refer to Plug-in Mixed Mounting Type Manifold Note 2) Without SI unit, the symbol is nil.
double, 3-position and 4-position valves
(from page 127). can be used on all manifold stations.
I/O unit stations Use of a 2-position single solenoid will
SI unit
Nil None result in an unused control signal. If this
0 Without SI unit
1 1 station is not desired, order with a specified
Q DeviceNet™
layout.
N PROFIBUS DP Note 2) Specified layout: Indicate the wiring
9 9 stations
V CC-Link specifications on the manifold
ZE EtherNet/IP™ Note 1) Without SI unit, the symbol is nil.
specification sheet. (Note that 2-
Note 2) SI unit is not included in I/O unit
D EtherCAT position double, 3-position and 4-
stations.
Note 1) I/O unit cannot be mounted without SI unit. position valves cannot be used where
Note 3) When I/O unit is selected, it is shipped
Note 2) Valve plate which connects manifold and single wiring has been specified.)
separately, and assembled by
SI unit is not mounted to a valve without Note 3) This also includes the number of
customer. Refer to the attached
SI unit. Refer to the EX600 catalog blanking plate assembly.
operation manual for mounting.
(CAT.E02-24) for mounting.
P, E port entry, SUP/EXH block assembly
How to Order Manifold Assembly
Internal Internal pilot, External
pilot Built-in silencer pilot
Example (SS5Y3-10S6쏔-쏔) P, E port entry U side (2 to 10 stations) U C G
Digital input unit Digital output unit 2-position single P, E port entry D side (2 to 10 stations) D E H
EX600-DXPD EX600-DYPB SY3100-5U1 (3 sets) P, E port entry both sides (2 to 24 stations) B F J
End plate Note 1) SI unit Note 1) 2-position double ∗ 3/5(E) port is plugged for the built-in silencer type.
EX600-ED2 EX600-SDN1 SY3200-5U1 (2 sets) ∗ When the built-in silencer type is used, keep the exhaust port from
coming in direct contact with water or other liquids.
0 1

Refer to the page on the right for .

o Mounting and Option


B A B A B A B A B A
2 3 14 A 14 A 14 A 14 A 14 A

PWR
D side OUT
0 1
U side
4 5
2 3
Symbol Mounting Option
12 B 12 B 12 B 12 B 12 B
PCI
BUS
IN
BUS
OUT None
Direct
8 7 Name plate (With station number)
mounting
Name plate (Without station number)
1 2 3 4 5 Valve stations
1 2 I/O unit stations Without name plate
DIN rail
Name plate (With station number)
SS5Y3-10S6Q42-05B-C6··· 1 set (Type 10 5-station manifold base part no.) mounting
Name plate (Without station number)
∗SY3100-5U1 ······················· 3 sets (2-position single part no.)
∗SY3200-5U1 ······················· 2 sets (2-position double part no.) Note 1) Enter the number of stations inside 첸. (Refer to “DIN Rail Option”
∗EX600-DXPD ····················· 1 set I/O unit part number (Station 1) below.)
∗EX600-DYPB ····················· 1 set I/O unit part number (Station 2) Note 2) Only direct mounting is available for Type 11 (Bottom ported).
The asterisk denotes the symbol for assembly. DIN Rail Option
Prefix it to the part nos. of the valve, etc. Nil Direct mounting
0 Without DIN rail (with bracket)
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted, then 3 For 3 stations
Specify a longer rail than the
the I/O units in order from the 1st station as shown in the figure above. total length of specified stations.
If the arrangement becomes complicated, specify on a manifold 24 For 24 stations
specification sheet. ∗ If the DIN rail must be mounted without an SI unit, select D0. Then, refer
Note 1) Do not enter the SI unit part number and the end plate part number together. to L3 of the dimensions for the DIN rail length and order separately.
Note 2) When mixing top ported configurations, select from page 96. (Refer to page 140 for the DIN rail part number.)
In this case, use caution as there is also output on the A and B port on base side. Refer to Series EX600 Fieldbus System (For Input/Output) (CAT.E02-24)
Specify on a manifold specification sheet if plugs are required on the A and B
for details on the EX600 Integrated-type (For I/O) Serial Transmission
port on base side.
System. (IP40 specifications apply depending on the selected I/O unit.)

89
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported

Flat Ribbon Cable


Symbol A, B port Symbol A, B port

D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow Note)
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow Note)

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —

Flat Ribbon Cable


B6 ø6 One-touch fitting 쎲 쎲 — BN9 ø5/16" One-touch fitting — 쎲 —
B8 ø8 One-touch fitting — 쎲 — Elbow port, mixed sizes

Block Box PC Wiring


LM∗ (Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Lead Wire
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000 Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single
B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double
K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
pressure type.
4 3-position exhaust center
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.) Nil Standard
B∗ 4-position dual 3-port valve (N.O./N.O.) T With power saving circuit (Continuous duty type)
C∗ 4-position dual 3-port valve (N.C./N.O.) ∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve. when the valve is continuously energized for
long periods of time. Type of mounting screw
Seal type ∗ Note the specified energizing time when Nil Round head combination screw
0 Rubber seal power saving circuit is selected. Refer to page
154. B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot
Light/surge voltage suppressor drop prevention construction to stop the
R External pilot
mounting screws from falling out when the
and common specification
and Plug Assembly/

valve is removed for maintenance etc.


One-touch Fittings

Back pressure check valve R With surge voltage suppressor (Non-polar) ∗ When ordering a valve individually, the base
(Built-in valve type) U With light/surge voltage suppressor (Non-polar) gasket is not included. Since the base gasket
Part No.

Nil None S With surge voltage suppressor (Positive common) is attached to the manifold, please order the
H Built-in Z With light/surge voltage suppressor (Positive common) base gasket separately if it is needed for
Manifold

maintenance service.
Options

∗ Only rubber seal type. Manifold installed type NS With surge voltage suppressor (Negative common) Refer to page 136 for part numbers of the
is available if the back pressure check valve NZ With light/surge voltage suppressor (Negative common) base gasket and mounting screw.
is required for a valve with metal seal. Refer
∗ Select a valve from R, U, S or Z when the SI ∗ "B" and "H" cannot be selected for the
to page 147 for Ordering Example. However,
unit polarity is positive common. Select a valve individual SUP/EXH spacer assembly or double
it is not recommended to use the built-in valve
Specific Product

from R, U, NS or NZ when the SI unit output check spacer assembly with residual pressure
type and the manifold installed type at the
Precautions

polarity is negative common. release valve.


same time because it will reduce the flow.
∗ Only “Z” and “NZ” types are available for the
∗ The built-in valve type back pressure check
product with power saving circuit.
valve is not available for the 3-position type.
90
Series SY3000/5000

Dimensions: Type 10/EX600 (M12 Connector)/Series SY3000


U C2
SS5Y3-10S6쏔 42 쏔- Stations D - C3, N1
C4, N3 (D) B C6, N7

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override Note 2)
(L5) L1
DIN rail holding screw 5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 47 8 DIN rail holding screw 1.5 4(A) port side
Communication connector
(For DIN rail mounting) : Blue (For rubber seal)
Power connector 2 x M4 mounting hole : Gray (For metal seal)
85.1 Light/surge 2(B) port side: Yellow
Marker groove
voltage suppressor

0 1

5.5
B A B A B A B A B A
2 3

92.6
14 A 14 A 14 A 14 A 14 A

35

83
106

PWR
90

OUT

60.5
0 1
4 5

40.9
2 3

4.6
BUS PCI BUS
12 B 12 B 12 B 12 B 12 B
8
IN OUT

8 7
8

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
86.6 FE
terminal 5.4 4 x M4 mounting hole

(
End plate (Fitting for the type with P/E
Digital input unit ports on the U and/or D sides)
Valve plate
Input connector
SI unit
Output connector One-touch fitting
Digital output unit Connector for handheld terminal [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
(Station 1)---(Station n)
11.5

: ø4, ø5/32"
: ø6, ø1/4"
8

1 P 1 P

63.1
56.6

13.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E

40.2
21.6
4 A4 A4 A4 A4 A
18
10.6
13.6
(For DIN rail
mounting)

7.5

One-touch fitting
(Pitch)
11.8

[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)


Applicable tube O.D.: ø8, ø5/16"

L1 = 10.5 x n1 + 135.5 + 47 x n2 Note 1) These figures show the “SS5Y3-10S6Q22-05D-C6”.


L2 = 10.5 x n1 + 42 Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82

L3: DIN Rail Overall Length


Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 235.5 248 248 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5
2 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 485.5 485.5 498 510.5
3 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5
4 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 473 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5
5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648
6 473 473 485.5 498 510.5 523 535.5 535.5 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698
7 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748
8 560.5 573 585.5 598 598 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798
9 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748 760.5 760.5 773 785.5 798 810.5 823 835.5 835.5
91
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/EX600 (7/8 Inch Connector)/Series SY3000

Replacement
U C2
SS5Y3-10S6쏔 53 쏔- Stations D - C3, N1
C4, N3 (D)

Parts
B C6, N7

D side U side

Metal Base
L3

Plug-in
5.3 L4
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override Note 2)

L6 L2 ( Push-turn locking slotted type:


)

Flat Ribbon Cable


5.5

D-sub Connector
Press, then rotate it.
DIN rail holding screw 47 8 DIN rail holding screw 1.5 4(A) port side

PC Wiring
Communication connector
(For DIN rail mounting) (For DIN rail mounting) : Blue (For rubber seal)
2 x M4 mounting hole
Light/surge : Gray (For metal seal)

EX510
Marker groove 2(B) port side: Yellow
voltage suppressor

0 1

5.5

Terminal D-sub Connector Plug-in Connector


Connecting Base
B A B A B A B A B A
2 3

92.6
14 A 14 A 14 A 14 A 14 A

35

83
106
90

60.5
0 1
4 5

40.9
PWR

2 3

4.6
BUS PCI BUS
12 B 12 B 12 B 12 B 12 B
8
53

IN OUT

Flat Ribbon Cable


8 7

Block Box PC Wiring


8

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
36.7 FE
terminal 5.4 4 x M4 mounting hole

(
Power connector End plate
(Fitting for the type with P/E
Digital input unit ports on the U and/or D sides)
Valve plate

Lead Wire
Input connector One-touch fitting
Output connector SI unit [4(A), 2(B) port]
Applicable tube O.D.: ø2
Digital output unit Connector for handheld terminal : ø3.2, ø1/8"

Connector
11.5

: ø4, ø5/32"

Circular
(Station 1)---(Station n)
: ø6, ø1/4"
8

1 P 1 P

EX120 EX126 EX260 EX250 EX600 EX500


63.1
56.6

13.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E

40.2
21.6
4 A4 A4 A4 A4 A
18
10.6
13.6
(For DIN rail

7.5
mounting)

One-touch fitting (Pitch)


11.8

[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)


Applicable tube O.D.: ø8, ø5/16"

Note 1) These figures show the “SS5Y3-10S6Q32-05D-C6”.


L1 = 10.5 x n1 + 152 + 47 x n2 Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 10.5 x n1 + 42 Note 3) Refer to page 124 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82

L3: DIN Rail Overall Length


Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
and Plug Assembly/

(n2)
One-touch Fittings

0 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5
Part No.

1 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
2 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 523 523
Manifold

348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573
Options

3
4 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 585.5 585.5 598 610.5 623
5 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673
6 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 648 648 660.5 673 685.5 698 710.5 710.5
Specific Product

7 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5
Precautions

8 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 710.5 710.5 723 735.5 748 760.5 773 773 785.5 798 810.5
9 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798 798 810.5 823 835.5 848 860.5
92
Series SY3000/5000

Dimensions: Type 10/EX600 (M12 Connector)/Series SY5000


U C4, N3
SS5Y5-10S6쏔 42 쏔- Stations D - C6, N7 (D)
B C8, N9

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
(L5) L1 Manual override Note 2)
(For DIN rail mounting)
Power connector
5.5
Communication connector
L6 L2
(Push-turn locking slotted type:
Press, then rotate it. )
47 8 DIN rail holding screw 1.5 4(A) port side
DIN rail
2 x M4 mounting hole (For DIN rail mounting) : Blue (For rubber seal)
Light/surge voltage suppressor : Gray (For metal seal)
85.1 Marker groove 2(B) port side: Yellow

0 1

5.5
BA BA BA BA BA
2 3

35
14 A 14 A 14 A 14 A 14 A

97.5
113.4
90

PWR
OUT
0 1
4 5

81.2
2 3
BUS
PCI
BUS 8

61.7
IN OUT

5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7

10.9
15.4

4.7
(5.9)
(8.3)

86.6 FE terminal 5.4


4 x M5 mounting hole
End plate
(Fitting for the type with P/E
Digital input unit
ports on the U and/or D sides)
Valve plate
Input connector
One-touch fitting
SI unit
Output connector [4(A), 2(B) port]
Connector for handheld terminal Applicable tube O.D.: ø4, ø5/32"
Digital output unit : ø6, ø1/4"
(Station 1)----------(Station n) : ø8, ø5/16"
11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

33.4
3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
12.4
14.1
8.7
7.5

One-touch fitting
(For DIN rail
mounting)

[1(P), 3/5(E) port] (Pitch)


11.8

Applicable tube O.D.: ø10, ø3/8" 20 18 P = 16 (20.5)

L1 = 16 x n1 + 141.5 + 47 x n2 Note 1) These figures show the “SS5Y5-10S6Q22-05D-C8”.


L2 = 16 x n1 + 48 Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L4 = L3 – 10.5 Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5

L3: DIN Rail Overall Length


Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 248 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598
2 298 310.5 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648
3 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698
4 385.5 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748
5 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5
6 485.5 498 523 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5
7 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5
8 573 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5
9 623 648 660.5 673 685.5 710.5 723 735.5 748 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973
93
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/EX600 (7/8 Inch Connector)/Series SY5000

Replacement
U C4, N3
SS5Y5-10S6쏔 53 쏔- Stations D - C6, N7 (D)

Parts
B C8, N9
D side U side
L3

Metal Base
5.3 L4

Plug-in
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override Note 2)

5.5 L6 L2 (Push-turn locking slotted type:


)

Flat Ribbon Cable


D-sub Connector
Press, then rotate it.
DIN rail holding screw 16.5 2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side

PC Wiring
(For DIN rail mounting) Communication connector (For DIN rail mounting) : Blue (For rubber seal)
Light/surge voltage suppressor : Gray (For metal seal)
DIN rail Marker groove 2(B) port side : Yellow

EX510
0 1

5.5

Terminal D-sub Connector Plug-in Connector


BA BA BA BA BA

Connecting Base
2 3

35
14 A 14 A 14 A 14 A 14 A
90

97.5
113.4
0 1
4 5

81.2
PWR

2 3
PCI 8
60.4

BUS BUS

61.7
IN OUT

5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7

Flat Ribbon Cable


Block Box PC Wiring
10.9
15.4

4.7
(8.3)

(5.9)
36.7
Power connector FE terminal 5.4 4 x M5 mounting hole

End plate (Fitting for the type with P/E


ports on the U and/or D sides)
Digital input unit

Lead Wire
Valve plate
Input connector One-touch fitting
SI unit
[4(A), 2(B) port]
Output connector Connector for handheld terminal Applicable tube O.D.: ø4, ø5/32"

Connector
Digital output unit (Station 1)----------(Station n) : ø6, ø1/4"

Circular
: ø8, ø5/16"
11.5

EX120 EX126 EX260 EX250 EX600 EX500


1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

33.4
3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
8.7
12.4
14.1
(For DIN rail
mounting)
7.5

One-touch fitting (Pitch)


11.8

[1(P), 3/5(E) port] 20 18 P = 16 (20.5)


Applicable tube O.D.: ø10, ø3/8"

Note 1) These figures show the “SS5Y5-10S6Q32-05D-C8”.


L1 = 16 x n1 + 158 + 47 x n2
Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 16 x n1 + 48
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5

L3: DIN Rail Overall Length


Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
and Plug Assembly/

(n2)
One-touch Fittings

0 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573
Part No.

1 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573 585.5 598 623
2 310.5 335.5 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5
Manifold

360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5
Options

3
4 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5 723 748 760.5
5 460.5 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5 810.5
6 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848
Specific Product

7 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848 873 885.5 898
Precautions

8 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5 948
9 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973 —
94
Plug-in Connector Connecting Base
EX600

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12S6 Q 2 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series SI unit output polarity, end plate type Valve stations


3 SY3000 Power supply Power supply Symbol Stations Note
SI unit output polarity with M12 with 7/8 inch
5 SY5000 connector connector 02 2 stations
Without SI unit Nil Double wiring Note 1)
SI unit positive common 2 3 16 16 stations
SI unit
SI unit negative common 4 5 02 2 stations
0 Without SI unit Specified layout Note 2)
Note 1) Without SI unit, the symbol is nil. (Available up to 32 solenoids)
Q DeviceNet™ 24 24 stations
Note 2) Ensure a match with the common
N PROFIBUS DP specifications of the value to be used. Note 1) Double wiring: 2-position single,
V CC-Link
double, 3-position and 4-position valves
ZE EtherNet/IP™ I/O unit stations can be used on all manifold stations.
D EtherCAT Nil None Use of a 2-position single solenoid will
Note 1) I/O unit cannot be mounted without SI 1 1 stations result in an unused control signal. If this
unit. is not desired, order with a specified
Note 2) Valve plate which connects manifold 9 9 stations layout.
and SI unit is not mounted to a valve Note 2) Specified layout: Indicate the wiring
without SI unit. Refer to the EX600 Note 1) Without SI unit, the symbol is nil. specifications on the manifold
catalog (CAT.E02-24) for mounting. Note 2) SI unit is not included in I/O unit specification sheet. (Note that 2-
stations. position double, 3-position and 4-
Note 3) When I/O unit is selected, it is shipped
position valves cannot be used where
separately, and assembled by
single wiring has been specified.)
customer. Refer to the attached
operation manual for mounting. Note 3) This also includes the number of
blanking plate assembly.

P, E port entry, SUP/EXH block assembly


Internal Internal pilot, External
pilot Built-in silencer pilot
P, E port entry U side (2 to 10 stations) U C Note) G
How to Order Manifold Assembly P, E port entry D side (2 to 10 stations) D E Note) H
P, E port entry both sides (2 to 24 stations) B — J
Example (SS5Y3-12S6쏔-쏔) ∗ For built-in silencer type, P and E ports are available on U and D sides.
3/5(E) port is plugged. The silencer exhaust port is located on the
Digital input unit Digital output unit 2-position single
opposite side of P, E port entry. (Example: When the P, E port entry is D
EX600-DXPD EX600-DYPB SY3130-5U1-C6 (3 sets)
side, the silencer exhaust port is U side.)
End plate Note) SI unit Note) 2-position double ∗ When the built-in silencer type is used, keep the exhaust port from
EX600-ED2 EX600-SDN1 SY3230-5U1-C6 (2 sets) coming in direct contact with water or other liquids.
0 1
Note) For SUP/EXH block assembly specifications, built-in silencer types
PE PE will have P port entry stipulated.
X X
3/5E B A B A B A B A B A 3/5E
2 3 4A 4A 4A 4A 4A

D side
PWR
OUT U side
P, E port size
4 5
0

2
1

3 1P 1P
(One-touch fittings)
2B 2B 2B 2B 2B
PCI
BUS
IN
BUS
OUT Symbol SY3000 SY5000
8 7
Nil ø8 ø10
1 2 3 4 5 Valve stations N ø5/16" ø3/8"
1 2 I/O unit stations ∗ For N, sizes are in inches.
SS5Y3-12S6Q42-05B ·········· 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ················· 3 sets (2-position single part no.)
Mounting
∗SY3230-5U1-C6 ················ 2 sets (2-position double part no.) Nil Direct mounting ∗ If the DIN rail must be
∗EX600-DXPD ······················ 1 set I/O unit part number (Station 1) D DIN rail mounting (With DIN rail) mounted without an SI
∗EX600-DYPB ······················ 1 set I/O unit part number (Station 2) D0 DIN rail mounting (Without DIN rail) unit, select D0. Then,
refer to L3 of the
The asterisk denotes the symbol for assembly. D3 For 3 stations Specify a longer rail than
dimensions for the DIN
Prefix it to the part nos. of the valve, etc.
the standard length. rail length and order
D24 For 24 stations separately. (Refer to
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted, then page 140 for the DIN
the I/O units in order from the 1st station as shown in the figure above. rail part number.)
If the arrangement becomes complicated, specify on a manifold specification
sheet. Refer to Series EX600 Fieldbus System (For Input/Output) (CAT.E02-24)
Note) Do not enter the SI unit part number and the end plate part number for details on the EX600 Integrated-type (For I/O) Serial Transmission
together. System. (IP40 specifications apply depending on the selected I/O unit.)

95
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


Coil type C2 ø2 One-touch fitting 쎲 —
2 2-position double

Block Box PC Wiring


3 3-position closed center
Nil Standard C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center
T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center ∗ Be sure to select the power saving circuit type C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) when the valve is continuously energized for C8 ø8 One-touch fitting — 쎲
long periods of time.
B∗ 4-position dual 3-port valve (N.O./N.O.) One-touch fitting (Inch)
∗ Note the specified energizing time when
C∗ 4-position dual 3-port valve (N.C./N.O.) Symbol A, B port SY3000 SY5000

Lead Wire
power saving circuit is selected. Refer to page
∗ Only rubber seal type is available for the 154. N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage N7 ø1/4" One-touch fitting 쎲 쎲

Connector
5 24 VDC N9 ø5/16" One-touch fitting — 쎲

Circular
Seal type
0 Rubber seal
Light/surge voltage suppressor

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
and common specification
Nil Rc
R With surge voltage suppressor (Non-polar) F G
U With light/surge voltage suppressor (Non-polar) N NPT
Pilot type S With surge voltage suppressor (Positive common)
Nil Internal pilot
T NPTF
Z With light/surge voltage suppressor (Positive common)
R External pilot ∗ Only Nil is available for M5.
NS With surge voltage suppressor (Negative common)
NZ With light/surge voltage suppressor (Negative common)
∗ Select a valve from R, U, S or Z when the SI
unit polarity is positive common. Select a valve Type of mounting screw
Back pressure check valve from R, U, NS or NZ when the SI unit output Nil Round head combination screw
Nil None polarity is negative common. B Hexagon socket head cap screw
H Built-in ∗ Only “Z” and “NZ” types are available for the
product with power saving circuit. K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve
is required for a valve with metal seal. Refer ∗ For “K” and “H”, the valve body cover has a
to page 147 for Ordering Example. However, !0 Manual override drop prevention construction to stop the
mounting screws from falling out when the
it is not recommended to use the built-in valve
type and the manifold installed type at the Nil: Non-locking D: Push-turn F: Slide locking valve is removed for maintenance etc.
same time because it will reduce the flow. push type locking slotted type ∗ When ordering a valve individually, the base
∗ The built-in valve type back pressure check type gasket is not included. Since the base gasket
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the
Part No.

individual SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

96
Type 10 Plug-in Connector Connecting Base
Side Ported EX250

SY3000/5000
Type 11
Bottom Ported
Series
How to Order Manifold

SS5Y 3 10 S Q 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Type Valve stations


Series
10 Side ported Symbol Stations Note
3 SY3000
11 Bottom ported∗ 02 2 stations
5 SY5000
∗ The SY5000 manifold base is used for the Double wiring Note 1)
SI unit bottom ported of the SY3000. When ordering, 16 16 stations
0 Without SI unit refer to Plug-in Mixed Mounting Type 02 2 stations
Manifold (from page 127). Specified layout Note 2)
Q DeviceNet™ (Negative common) (Available up to 32 solenoids)
N PROFIBUS DP (Negative common) 24 24 stations
V CC-Link (Positive common) Input block stations Note 1) Double wiring: 2-position single, double, 3-
AS-Interface, (Negative common) Nil None position and 4-position valves can be used
TA 1 1 station on all manifold stations.
(8 in/8 out, 31 slave modes, 2 isolated common type)
Use of a 2-position single solenoid will
AS-Interface, (Negative common)
TB 8 8 stations result in an unused control signal. If this is
(4 in/4 out, 31 slave modes, 2 isolated common type) not desired, order with a specified layout.
AS-Interface, (Negative common) Note) Without SI unit, the symbol is nil. The Note 2) Specified layout: Indicate the wiring
TC maximum number of stations is limited for
(8 in/8 out, 31 slave modes, 1 common type) specifications on the manifold specification
AS-Interface, (Negative common) the AS-Interface applicable SI unit. sheet. (Note that 2-position double, 3-
TD position and 4-position valves cannot be
(4 in/4 out, 31 slave modes, 1 common type)
used where single wiring has been
Y CANopen (Negative common) Input block type
specified.)
ZE EtherNet/IP™ (Negative common) PNP input NPN input When determining the number of valve
Note 1) Ensure that the specifications match those of (Positive common) (Negative common) stations, note that the maximum number of
the common specifications of the valve to be Without input block Nil solenoids for the AS-Interface applicable
used. M12, 2 inputs A D SI unit specification is as follows.
Note 2) Input block cannot be mounted without SI unit. • 8 in/8 out specification: Max. 8 solenoids
Note 3) The supply current from the SI unit of AS-Interface
M12, 4 inputs B E
• 4 in/4 out specification: Max. 4 solenoids
applicable 1 power supply system specification to M8, 4 inputs C F Note 3) This also includes the number of blanking
the input block and valve is limited. Note) Without SI unit, the symbol is nil. plate assembly.
Note 4) For the product without the SI unit (S0),
How to Order Manifold Assembly note the maximum number of solenoids of
the SI unit that will be mounted. If the
layout is specified, indicate it on the
Example (SS5Y3-10S쏔-쏔) 3-position closed manifold specification sheet.
2-position double (24 VDC) center (24 VDC)
SY3300-5U1 (1 set) P, E port entry, SUP/EXH block assembly
SY3200-5U1 (1 set)
Internal Internal pilot, External
pilot Built-in silencer pilot
2-position single (24 VDC) P, E port entry U side (2 to 10 stations) U C G
SY3100-5U1 (3 sets) P, E port entry D side (2 to 10 stations) D E H
P, E port entry both sides (2 to 24 stations) B F J
ide
Us ∗ 3/5(E) port is plugged for the built-in silencer type.
∗ When the built-in silencer type is used, keep the exhaust port from
s
n
tio
ta

coming in direct contact with water or other liquids.


S

23 Refer to the page on the right for .


1
ide
Ds
o Mounting and Option
Manifold base (5 stations) DIN Rail Option
Symbol Mounting Option
SS5Y3-10SQ1C-05D-C6 Nil Direct mounting
Nil None
SS5Y3-10SQ1C-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) AA Direct Name plate (With station number) 0 Without DIN rail (with bracket)
∗SY3100-5U1······················ 3 sets (2-position single part no.) mounting
BA Name plate (Without station number) 3 For 3 stations Specify a longer rail
∗SY3200-5U1······················ 1 set (2-position double part no.) than the total length of
D첸 Without name plate
∗SY3300-5U1······················ 1 set (3-position closed center part no.) DIN rail 24 For 24 stations specified stations.
A첸 mounting Name plate (With station number)
The asterisk denotes the symbol for assembly. B첸 Name plate (Without station number)
Prefix it to the part nos. of the valve, etc.
Note 1) Enter the number of stations inside 첸. (Refer to “DIN Rail Option”
• The valve arrangement is numbered as the 1st station from the D side. below.)
• Under the manifold part number, state the valves to be mounted in order Note 2) Only direct mounting is available for Type 11 (Bottom ported).
from the 1st station as shown in the figure above. If the arrangement ∗ When it is necessary to mount a DIN rail without an SI unit, select D0
becomes complicated, specify on a manifold specification sheet. and order DIN rail length separately, referring to L3 in the dimensions.
Note) When mixing top ported configurations, select from page 102. Refer to page 140 for part numbers of DIN rail.
In this case, use caution as there is also output on the A and B port on base side.
Refer to Reduced Wiring Fieldbus System (Serial Transmission) in Electric Products (CAT.E150)
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side. for details on the EX250 Integrated-type (For Input/Output) Serial Transmission System.

97
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
Symbol A, B port Symbol A, B port

Flat Ribbon Cable


D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 쎲 쎲 쎲

Elbow Note)
ø6 One-touch fitting — LN9 ø5/16" One-touch fitting — —
L8 쎲 쎲
Elbow Note)

ø8 One-touch fitting — — BN3 ø5/32" One-touch fitting — —


B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —
B6 쎲 쎲 BN9 쎲

Flat Ribbon Cable


ø6 One-touch fitting — ø5/16" One-touch fitting — —
B8 ø8 One-touch fitting — 쎲 — LM∗
Elbow port, mixed sizes

Block Box PC Wiring


(Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the size on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting

Lead Wire
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000 Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
pressure type.
4 3-position exhaust center
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.) Nil Standard
B∗ 4-position dual 3-port valve (N.O./N.O.) T With power saving circuit (Continuous duty type)
C∗ 4-position dual 3-port valve (N.C./N.O.)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve. when the valve is continuously energized for
long periods of time.
Type of mounting screw
Seal type ∗ Note the specified energizing time when Nil Round head combination screw
0 Rubber seal power saving circuit is selected. Refer to page B Hexagon socket head cap screw
1 Metal seal 154. K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot drop prevention construction to stop the
R External pilot Light/surge voltage suppressor mounting screws from falling out when the
valve is removed for maintenance etc.
and Plug Assembly/

and common specification


One-touch Fittings

Back pressure check valve ∗ When ordering a valve individually, the base
(Built-in valve type) R With surge voltage suppressor (Non-polar) gasket is not included. Since the base gasket
Part No.

U With light/surge voltage suppressor (Non-polar) is attached to the manifold, please order the
Nil None base gasket separately if it is needed for
S With surge voltage suppressor (Positive common)
H Built-in maintenance service.
Z With light/surge voltage suppressor (Positive common)
Manifold
Options

∗ Only rubber seal type. Manifold installed type Refer to page 136 for part numbers of the
NS With surge voltage suppressor (Negative common)
is available if the back pressure check valve base gasket and mounting screw.
is required for a valve with metal seal. Refer NZ With light/surge voltage suppressor (Negative common) ∗ "B" and "H" cannot be selected for the
to page 147 for Ordering Example. However, ∗ “R" and “U” are applicable for every SI unit. individual SUP/EXH spacer assembly or double
it is not recommended to use the built-in valve However, “S” and “Z” can be used only for CC- check spacer assembly with residual pressure
Specific Product

type and the manifold installed type at the Link applicable unit and “NS” and “NZ” are for release valve.
Precautions

same time because it will reduce the flow. units which are not CC-Link applicable.
∗ The built-in valve type back pressure check ∗ Only “Z” and “NZ” types are available for the
valve is not available for the 3-position type. product with power saving circuit.
98
Series SY3000/5000

Dimensions: Type 10/EX250/Series SY3000


C2
U
SS5Y3-10S쏔- Stations D - C3, N1
C4, N3 (D)
B C6, N7

D side U side

(L5) L1 Manual override Note 2)

DIN rail holding screw 18 21 63 (


Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
Light/surge voltage suppressor
: Gray (For metal seal)
DIN rail holding screw
DIN rail 2(B) port side: Yellow
(For DIN rail mounting)

8
B A B A B A B A B A

5.5

92.6
14 A 14 A 14 A 14 A 14 A

35

83
0

1
66

60.5
2

40.9
3

4.6
12 B 12 B 12 B 12 B 12 B

4.6
2.7

1.7
SI unit
)
C6: 3.6
N7: 7.4
(4.9)
7.5

2 x M4 mounting hole Input block 4 x M4 mounting hole


(
(Fitting for the type with P/E
5.5 L6 L2 1.5 ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
One-touch fitting : ø3.2, ø1/8"
[1(P), 3/5(E) port] (Station 1)---(Station n)
: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16" : ø6, ø1/4"

1 P 1 P
0
BUS
13.6
10.6

63.1
1
56.6
60

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

2
PWR
21.6

4 A4 A4 A4 A4 A
3
18

13.2

(For DIN rail


mounting)
7.5

M3 (Pitch)
11.8

18.3 15.5 P = 10.5 (17.8)


4 x M8 2 x M12
3-pin socket

Note 1) These figures show the “SS5Y3-10SQ1A-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L1 = 10.5 x n1 + 135.5 + 21 x n2 Note 3) Refer to page 124 for dimensions of A or B port top-ported type.
L2 = 10.5 x n1 + 42
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 21 x n2 + 82

L3: DIN Rail Overall Length


Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5
2 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5
3 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
4 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498
5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523
6 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548
7 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5
8 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5
99
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/EX250/Series SY5000

Replacement
U C4, N3
SS5Y5-10S쏔- Stations D - C6, N7 (D)

Parts
B C8, N9

D side U side

Metal Base
(L5) L1

Plug-in
Manual override Note 2)
18 21 63
DIN rail holding screw
(For DIN rail mounting)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)

Flat Ribbon Cable


D-sub Connector
DIN rail holding screw Light/surge voltage suppressor : Gray (For metal seal)
(For DIN rail mounting)

PC Wiring
Input block 2(B) port side: Yellow

DIN rail SI unit

EX510
8
BA BA BA BA BA

5.5
14 A 14 A 14 A 14 A 14 A

35
0

97.5

113.4

Terminal D-sub Connector Plug-in Connector


1
66

Connecting Base
2

81.2
3

61.7
5.5
12 B 12 B 12 B 12 B 12 B
23.5

Flat Ribbon Cable


10.9

Block Box PC Wiring


4.7
(5.9)

2 x M4 mounting hole
(8.3)

4 x M5 mounting hole
5.5 L6 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)

Lead Wire
L3
One-touch fitting
[4(A), 2(B) port]

Connector
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"

Circular
One-touch fitting : ø6, ø1/4"
[1(P), 3/5(E) port] : ø8, ø5/16"
Applicable tube O.D.: ø10, ø3/8"

EX120 EX126 EX260 EX250 EX600 EX500


0
BUS 1 P 1 P

73.2
1 2 B2 B2 B2 B2 B
56.6
60

12.4

13.2

2
33.4

3/5 E 3/5 E
29.1

PWR
3
4 A4 A4 A4 A4 A
14.1
8.7
(For DIN rail
mounting)

7.5

M3 (Pitch)
11.8

20 18 P = 16 (20.5)
4 x M8 2 x M12
3-pin socket

L1 = 16 x n1 + 141.5 + 21 x n2 Note 1) These figures show the “SS5Y5-10SQ1A-05D-C8”.


L2 = 16 x n1 + 48 Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.5

L3: DIN Rail Overall Length


Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
and Plug Assembly/
One-touch Fittings

block
stations (n2)
Part No.

0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498 510.5 523 548 560.5 573
Manifold

248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598
Options

2
3 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623
4 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5
5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 585.5 598 610.5 623 648 660.5
Specific Product

6 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5 685.5
Precautions

7 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5 648 673 685.5 698
8 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 573 598 610.5 623 648 660.5 673 685.5 710.5 723
100
Plug-in Connector Connecting Base
EX250

SY3000/5000
Type 12
Top Ported
Series
How to Order Manifold

SS5Y 3 12S Q 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series SI unit Valve stations


3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Negative common) 02 2 stations
N PROFIBUS DP (Negative common) Double wiring Note 1)
V CC-Link (Positive common) 16 16 stations
Input block stations AS-Interface, (Negative common) 02 2 stations
TA Specified layout Note 2)
Nil None (8 in/8 out, 31 slave modes, 2 isolated common type) (Available up to 32 solenoids)
1 1 station AS-Interface, (Negative common) 24 24 stations
TB
(4 in/4 out, 31 slave modes, 2 isolated common type) Note 1) Double wiring: 2-position single, double, 3-
8 8 stations AS-Interface, (Negative common) position and 4-position valves can be used on
TC all manifold stations.
Note) Without SI unit, the symbol is nil. The (8 in/8 out, 31 slave modes, 1 common type)
Use of a 2-position single solenoid will result in
maximum number of stations is limited for AS-Interface, (Negative common)
TD an unused control signal. If this is not desired,
the AS-Interface applicable SI unit. (4 in/4 out, 31 slave modes, 1 common type) order with a specified layout.
Y CANopen (Negative common) Note 2) Specified layout: Indicate the wiring
ZE EtherNet/IP™ (Negative common) specifications on the manifold specification
Input block type sheet. (Note that 2-position double, 3-position
Note 1) Ensure a match with the common and 4-position valves cannot be used where
PNP input NPN input specifications of the value to be used. single wiring has been specified.)
(Positive common) (Negative common) Note 2) Input block cannot be mounted without When determining the number of valve
Without input block Nil SI unit. stations, note that the maximum number of
M12, 2 inputs A D Note 3) The supply current from the SI unit of solenoids for the AS-Interface applicable SI
AS-Interface applicable 1 power supply unit specification is as follows.
M12, 4 inputs B E • 8 in/8 out specification: Max. 8 solenoids
M8, 4 inputs C F system specification to the input block
• 4 in/4 out specification: Max. 4 solenoids
and valve is limited. Note 3) This also includes the number of blanking plate
Note) Without SI unit, the symbol is nil.
assembly.
Note 4) For the porduct without the SI unit (S0), note
the maximum number of solenoids of the SI
unit that will be mounted. If the layout is
specified, indicate it on the manifold
specification sheet.
How to Order Manifold Assembly P, E port entry, SUP/EXH block assembly
Internal Internal pilot, External
Example (SS5Y3-12S쏔-쏔) 3-position closed
pilot Built-in silencer pilot
2-position double (24 VDC) center (24 VDC) P, E port entry U side (2 to 10 stations) U C Note) G
SY3230-5U1-C6 (1 set) SY3330-5U1-C6 (1 set) P, E port entry D side (2 to 10 stations) D E Note) H
2-position single (24 VDC)
P, E port entry both sides (2 to 24 stations) B — J
SY3130-5U1-C6 (3 sets) ∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is
plugged. The silencer exhaust port is located on the opposite side of P, E port entry.
(Example: When the P, E port entry is D side, the silencer exhaust port is U side.)
∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact
ide with water or other liquids.
Us Note) For SUP/EXH block assembly specifications, built-in silencer types will have P port
entry stipulated.
s
n
tio
ta
S

P, E port size (One-touch fittings)


23
1 Symbol SY3000 SY5000
ide
Ds Nil ø8 ø10
N ø5/16" ø3/8" ∗ For N, sizes are in inches.
Manifold base (5 stations)
SS5Y3-12SQ1C-05D
Mounting
SS5Y3-12SQ1C-05D ··· 1 set (Type 12 5-station manifold base part no.) Nil Direct mounting ∗ If the DIN rail must be
∗SY3130-5U1-C6 ··········· 3 sets (2-position single part no.) DIN rail mounting mounted without an SI unit,
∗SY3230-5U1-C6 ··········· 1 set (2-position double part no.) D select D0. Then, refer to L3
(With DIN rail)
∗SY3330-5U1-C6 ··········· 1 set (3-position closed center part no.) of the dimensions for the
DIN rail mounting
The asterisk denotes the symbol for assembly. D0 DIN rail length and order
(Without DIN rail)
Prefix it to the part nos. of the valve, etc. separately. (Refer to page
D3 For 3 stations Specify a longer rail than 140 for the DIN rail part
• The valve arrangement is numbered as the 1st station from the D side. the standard length. number.) (Refer to page 140
• Under the manifold part number, state the valves to be mounted in order D24 For 24 stations for the DIN rail part number.)
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet. Refer to Reduced Wiring Fieldbus System (Serial Transmission) in Electric Products (CAT.E150)
for details on the EX250 Integrated-type (For Input/Output) Serial Transmission System.

101
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Coil type Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Nil Standard C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center T With power saving circuit (Continuous duty type) C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center ∗ Be sure to select the power saving circuit type
C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center when the valve is continuously energized for C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) long periods of time. C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Note the specified energizing time when One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) power saving circuit is selected. Refer to page Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the 154.
N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage
5 24 VDC
N7 ø1/4" One-touch fitting 쎲 쎲

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
Seal type
Light/surge voltage suppressor
0 Metal seal
and common specification

EX120 EX126 EX260 EX250 EX600 EX500


1 Rubber seal Thread type
R With surge voltage suppressor (Non-polar)
U With light/surge voltage suppressor (Non-polar) Nil Rc
S With surge voltage suppressor (Positive common) F G
Pilot type Z With light/surge voltage suppressor (Positive common) N NPT
Nil Rubber seal NS With surge voltage suppressor (Negative common) T NPTF
R Metal seal NZ With light/surge voltage suppressor (Negative common) ∗ Only Nil is available for M5.
∗ “R" and “U” are applicable for every SI unit.
However, “S” and “Z” can be used only for
Back pressure check valve CC-Link applicable unit and “NS” and “NZ”
(Built-in valve type) are for units which are not CC-Link
Type of mounting screw
applicable. Nil Round head combination screw
Nil None
H Built-in
∗ Only “Z” and “NZ” types are available for the B Hexagon socket head cap screw
product with power saving circuit. K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type
is available if the back pressure check valve
H Hexagon socket head cap screw (Falling-out-prevention type)
is required for a valve with metal seal. Refer ∗ For “K” and “H”, the valve body cover has a
to page 147 for Ordering Example. However, !0 Manual override drop prevention construction to stop the
it is not recommended to use the built-in valve Nil: Non-locking D: Push-turn F: Slide locking mounting screws from falling out when the
type and the manifold installed type at the valve is removed for maintenance etc.
push type locking slotted type
same time because it will reduce the flow. ∗ When ordering a valve individually, the base
type
∗ The built-in valve type back pressure check gasket is not included. Since the base gasket
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ "B" and "H" cannot be selected for the
Part No.

individual SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

102
Type 10
Plug-in Connector Connecting Base
Side Ported EX260

Series SY3000/5000
Type 11
Bottom Ported
RoHS
How to Order Manifold

Refer to page 123 for


Type 11/Bottom
SS5Y 3 10 S NA N 05 U C6
ported dimensions.
q w e r t y u i o
q Series t Valve stations y P, E port entry
3 SY3000
5 SY5000
In the case of the 32-output SI unit U U side (2 to 10 stations)
Symbol Stations Note D D side (2 to 10 stations)
w Type 02 2 stations B Both sides (2 to 24 stations)
Double wiring Note 1)
10
11
Side ported
Bottom ported 16 16 stations
u SUP/EXH block assembly
02 2 stations Nil Internal pilot
∗ The SY5000 manifold base is used for the bottom Specified layout Note 2) S Internal pilot, Built-in silencer
ported of the SY3000. When ordering, refer to (Available up to 32 solenoids)
Plug-in Mixed Type Manifold (from page 127). 24 24 stations R External pilot
∗ 3/5(E) port is plugged for the built-in silencer type.
e SI unit specifications In the case of the 16-output SI unit ∗ When the built-in silencer type is used, keep the
Symbo Protocol
Number of outputs Communication connector Symbol Stations Note exhaust port from coming in direct contact with
0 Without SI unit 02 2 stations water or other liquids.
QA
DeviceNet™
32
M12 08 16 stations
Double wiring Note 1) o Mounting and Option
QB 16 Symbol Mounting Option
NA 32 02 2 stations
M12 Specified layout Note 2) None
NB PROFIBUS 16 Direct
(Available up to 16 solenoids) Name plate (With station number)
DP 16 24 stations mounting
NC 32 Name plate (Without station number)
D-sub Note)
ND 16 Note 1) Double wiring: 2-position single, double, 3- Without name plate
VA 32 position and 4-position valves can be used DIN rail
CC-Link M12 Name plate (With station number)
on all manifold stations. mounting
VB 16 Name plate (Without station number)
Use of a 2-position single solenoid will
DA 32 result in an unused control signal. If this is Note 1) Enter the number of stations inside 첸.
EtherCAT M12
DB 16 not desired, order with a specified layout (Refer to “DIN Rail Option” below.)
FA 32 Note 2) Specified layout: Indicate the wiring Note 2) Only direct mounting is available for Type
PROFINET M12
FB 16 specifications on the manifold specification 11 (Bottom ported).
Note) IP40 for the D-sub applicable communication sheet. DIN Rail Option
connector specification. (Note that 2-position double, 3-position Nil Direct mounting
For SI unit part number, refer to page 136. and 4-position valves cannot be used 0 Without DIN rail (with bracket)
DIN rail cannot be mounted without SI unit. where single wiring has been specified.)
Note 3) This also includes the number of blanking
3 For 3 stations
Specify a longer rail than the
r SI unit output polarity plate assembly.
24 For 24 stations
total length of specified stations.
Nil Positive common Note 4) For the model without the SI unit (S0), note
the maximum number of solenoids of the ∗ When it is necessary to mount a DIN rail without an
N Negative common
SI unit that will be mounted. If the layout is SI unit, select D0 and order DIN rail length
Note 1) Ensure a match with the common specified, indicate it on the manifold separately, referring to L3 in the dimensions. Refer
specifications of the value to be used. specification sheet. to page 140 for part numbers of DIN rail.
Note 2) Without SI unit, the symbol is nil. A, B port size (Inch)
i A, B port size (Metric) Symbol A, B port
Type 10/
Side ported
Type 11/
Bottom ported
Type 10/
Side ported
Type 11/
Bottom ported
SY3000 SY5000 SY5000
Symbol A, B port
SY3000 SY5000 SY5000 ø1/8" One-touch fitting
ø2 One-touch fitting ø5/32" One-touch fitting
Straight

ø3.2 One-touch fitting ø1/4" One-touch fitting


Straight

ø4 One-touch fitting ø5/16" One-touch fitting


ø6 One-touch fitting Straight port, mixed sizes
ø5/32" One-touch fitting
Upward

ø8 One-touch fitting
Straight port, mixed sizes ø1/4" One-touch fitting
ø4 One-touch fitting ø5/16" One-touch fitting
Downward Upward

Elbow
Downward

ø6 One-touch fitting ø5/32" One-touch fitting


ø8 One-touch fitting ø1/4" One-touch fitting
Elbow

ø4 One-touch fitting ø5/16" One-touch fitting


ø6 One-touch fitting Elbow port, mixed sizes (Including upward and downward piping)
ø8 One-touch fitting P, E port size (One-touch fittings)
Elbow port, mixed sizes (Including upward and downward piping) ∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”,
P, E port size (One-touch fittings) indicate it on the manifold specification sheet for the P, E port fitting direction.

Note) To avoid interference with the body or piping, select downward elbow
Refer to Fieldbus System (CAT.E02-25) for details on the EX260
port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
Integrated-type (For Output) Serial Transmission System.

103
Plug-in Connector Connecting Base Series SY3000/5000

Construction Specifications
How to Order Manifold Assembly

Replacement
Parts
SS5Y3-10SNAN-04D-C6···1 set (Type 10 4-station manifold base part no.)
2-position double (24 VDC) ∗SY3100-5U1·····················2 sets (2-position single part no.)

Metal Base
2-position single (24 VDC)
SY3200-5U1 (1 set) ∗SY3200-5U1·····················1 set (2-position double part no.)
SY3100-5U1 (2 sets)

Plug-in
3-position closed center (24 VDC) ∗SY3300-5U1·····················1 set (3-position closed center part no.)
SY3300-5U1 (1 set)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.

Flat Ribbon Cable


D-sub Connector
• The valve arrangement is numbered as the 1st station from the D side.

PC Wiring
• Under the manifold part number, state the valves to be mounted in
order from the 1st station as shown in the figure above.
If the arrangement becomes complicated, specify on a manifold
ide

EX510
Us specification sheet.
s
n
tio
ta

Note) When mixing top ported configurations, select from page 108.
S

3
2 Specify on a manifold specification sheet if plugs are required on
1

Terminal D-sub Connector Plug-in Connector


the A and B port on the manifold.
ide

Connecting Base
Manifold base (4 stations)
Ds
SS5Y3-10SNAN-04D-C6

How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Flat Ribbon Cable


Block Box PC Wiring
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

Lead Wire
q Series Pilot valve option !0 Manual override
3 SY3000 Standard (0.7 MPa) Nil: D: Push-turn F: Slide locking
5 SY5000 Quick response type (0.7 MPa)

Connector
Non-locking locking slotted type

Circular
High pressure type (1.0 MPa) push type type
w Type of actuation ∗ Only metal seal type is available for the high
2-position single pressure type.

EX120 EX126 EX260 EX250 EX600 EX500


2-position double
Coil type
3-position closed center
3-position exhaust center Nil Standard
3-position pressure center T With power saving circuit (Continuous duty type)
4-position dual 3-port valve (N.C./N.C.) ∗ Be sure to select the power saving circuit type
4-position dual 3-port valve (N.O./N.O.) when a valve is continuously energized for !1 Type of mounting screw
4-position dual 3-port valve (N.C./N.O.) long periods of time. Nil Round head combination screw
∗ Only rubber seal type is available for the 4- ∗ Note the specified energizing time when power B Hexagon socket head cap screw
position dual 3-port valve. saving circuit is selected. Refer to page 154. Round head combination screw
K (Falling-out-prevention type)
e Seal type Rated voltage
H
Hexagon socket head cap screw
0 Rubber seal 5 24 VDC (Falling-out-prevention type)
1 Metal seal ∗ For “K” and “H”, the valve body cover has a
Light/surge voltage suppressor drop prevention construction to stop the
r Pilot type and common specification mounting screws from falling out when the
Nil Internal pilot R With surge voltage suppressor (Non-polar) valve is removed for maintenance etc.
U With light/surge voltage suppressor (Non-polar) ∗ When ordering a valve individually, the base
R External pilot
S With surge voltage suppressor (Positive common) gasket is not included. Since the base gasket
is attached to the manifold, please order the
t Back pressure check valve Z
NS
With light/surge voltage suppressor (Positive common)
With surge voltage suppressor (Negative common)
base gasket separately if it is needed for
(Built-in valve type) maintenance service.
Nil None
NZ With light/surge voltage suppressor (Negative common) Refer to page 136 for part numbers of the
base gasket and mounting screw.
and Plug Assembly/

H Built-in
One-touch Fittings

∗ Select a valve from R, U, S or Z when the SI


unit output polarity is Nil (Positive common). ∗ “B” and “H” cannot be selected for the
∗ Only rubber seal type. Select a valve from R, U, NS or NZ when the individual SUP/EXH spacer assembly or
Part No.

Manifold installed type is available if the back SI unit output polarity is N (Negative common). double check spacer assembly with residual
pressure check valve is required for a valve ∗ Only “Z” and “NZ” types are available for the pressure release valve.
Manifold

with metal seal. Refer to page 147 for details.


Options

product with power saving circuit.


However, it is not recommended to use the
built-in valve type and the manifold installed
type at the same time because it will reduce
the flow.
Specific Product

∗ The built-in valve type back pressure check


Precautions

valve is not available for the 3-position type.


Protective class
class (Mark: )
104
Series SY3000/5000

Dimensions: Type 10/For EX260/Series SY3000


U C2
D - C3, N1
N3(D)
B C4,
C6, N7

D side U side
Manual override

(Push-turn locking slotted type:


Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side: Blue (For rubber seal)
L1
: Gray (For metal seal)
(For DIN rail mounting)
2(B) port side: Yellow
Light/surge voltage
suppressor (8)
DIN rail

(5.5)
B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A

83
80.2

60.5
(40.9)
4.6
12 B 12 B 12 B 12 B
22.2

4.6
1.7
(4.9)

SI unit 4 x M4 mounting hole


)
C6:3.6
N7:7.4

(Fitting for the type with P/E


ports on U and/or D sides)
(

L2 1.5
(5.3) L4
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2
[Communication connector D-sub] Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
(Station 1)----------- (Station n) : ø4, ø5/32"
: ø6, ø1/4"

BUS BUS OUT manual override)


(Slide locking

1 P 1 P 1 P
76.7

76.7

63.1
68.8
10.6
13.6

BUS IN
56.6

3/5 E 2 B2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

PWR 4 A4 PWR
21.6

4 A4 A4 A4 A4 A
18

46.5 46.5 (17.8)


(7.5)
(11.8)

15.5 (Pitch)
P=10.5

Note 1) These figures show the “SS5Y3-10SQA-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

n: stations 18 19 20 21 22 23 24
L1 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 231 241.5 252 262.5 273 283.5 294
L3 298 310.5 323 335.5 348 348 360.5
L4 287.5 300 312.5 325 337.5 337.5 350
L5 13 14 15 16 17 12 13

105
Plug-in Connector Connecting Base Series SY3000/5000

Construction Specifications
Dimensions: Type 10/For EX260/Series SY5000

Replacement
U C4, N3
SS5Y5-10S쏔쏔- D - C6, N7 (D)

Parts
B C8, N9

Metal Base
D side U side
Manual override

Plug-in
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side: Blue (For rubber seal)
L1
: Gray (For metal seal)

Flat Ribbon Cable


(For DIN rail mounting)

D-sub Connector
2(B) port side: Yellow
Light/surge voltage suppressor

PC Wiring
(8)
DIN rail

EX510
(5.5)
B A B A B A B A

(35)

Terminal D-sub Connector Plug-in Connector


14 A 14 A 14 A 14 A

Connecting Base
97.5
113.4
101

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B

Flat Ribbon Cable


Block Box PC Wiring
10.9
1.4

4.7
(5.9)
(8.3)

SI unit
4 x M5 mounting hole

34.2 L2 1.5
(5.3) (L4)

Lead Wire
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E
(L3) ports on U and/or D sides)

Connector
One-touch fitting

Circular
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.:: ø4, ø5/32"
[Communication connector D-sub] [1(P), 3/5(E) port] : ø6, ø1/4"

EX120 EX126 EX260 EX250 EX600 EX500


Applicable tube O.D.: ø10 (Station 1)----------- (Station n) : ø8, ø5/16"
: ø3/8"

BUS manual override)


(Slide locking

BUS OUT
76.7

1 P
2 B2
78.9
76.7

14.1

1 P 1 P
73.2

3/5 E BUS IN 2 B2 B2 B2 B2 B
56.6

PWR

3/5 3/5
33.4

E E
29.1

4 A4 PWR

4 A4 A4 A4 A4 A

48.2
8.7
12.4

(11.8)

(Pitch) (20.5)
(7.5)

48.2 18 P=16

Note 1) These figures show the “SS5Y5-10SQA-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.

n: stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7
and Plug Assembly/
One-touch Fittings

L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5
Part No.

L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5
Manifold
Options

n: stations 18 19 20 21 22 23 24
L1 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 336 352 368 384 400 416 432
Specific Product

L3 410.5 423 435.5 448 473 485.5 498


Precautions

L4 400 412.5 425 437.5 462.5 475 487.5


L5 17 15 13.5 11.5 16 14.5 12.5

106
Plug-in Connector Connecting Base
EX260

Series SY3000/5000
Type 12
Top Ported
RoHS

How to Order Manifold

Refer to pages 124,


125 for Type 12/Top SS5Y 3 12S NA N 05 U
ported dimensions.
q w e r t y u i
q Series r Valve stations y SUP/EXH block assembly
3 SY3000 In the case of the 32-output SI unit Nil Internal pilot
5 SY5000 Symbol Stations Note S Internal pilot, Built-in silencer
02 2 stations R External pilot
Double wiring Note 1)
w SI unit specifications 16 16 stations
∗ For built-in silencer type, P and E ports are
available on U and D sides. 3/5(E) port is
Number of Communication 02 2 stations plugged. The silencer exhaust port is located
Symbol Protocol outputs connector Specified layout Note 2) on the opposite side of P, E port entry.
0 Without SI unit (Available up to 32 solenoids) (Example: When the P, E port entry is D side,
24 24 stations
QA 32 the silencer exhaust port is U side.)
DeviceNet™ M12 In the case of the 16-output SI unit
QB 16 ∗ When the built-in silencer type is used, keep
Symbol Stations Note the exhaust port from coming in direct contact
NA 32
M12 02 2 stations with water or other liquids.
NB PROFIBUS 16
Double wiring Note 1)
NC DP 32
D-sub Note) 08 8 stations
ND 16
VA 32
02 2 stations P, E port size (One-touch fittings)
CC-Link M12 Specified layout Note 2)
VB 16 (Available up to 16 solenoids) Symbol SY3000 SY5000
DA 32
16 16 stations Nil ø8 ø10
EtherCAT M12 Note 1) Double wiring: 2-position single, double, 3-
DB 16 N ø5/16" ø3/8"
position and 4-position valves can be used
FA 32 ∗ For N, sizes are in inches.
PROFINET M12 on all manifold stations.
FB 16 Use of a 2-position single solenoid will
Note) IP40 for the D-sub applicable communication result in an unused control signal. If this is
connector specification. not desired, order with a specified layout. Mounting
For SI unit part number, refer to page 136. Note 2) Specified layout: Indicate the wiring Nil Direct mounting
DIN rail cannot be mounted without SI unit. specifications on the manifold specification
sheet.
D DIN rail mounting (With DIN rail)
(Note that 2-position double, 3-position D0 DIN rail mounting (Without DIN rail)
and 4-position valves cannot be used D3 For 3 stations
e SI unit output polarity where single wiring has been specified.)
Specify a longer rail than
the standard length.
Nil Positive common (NPN) Note 3) This also includes the number of blanking D24 For 24 stations
plate assembly.
N Negative common (PNP) Note 4) For the model without the SI unit (S0), note
∗ When it is necessary to mount a DIN rail without
Note 1) Ensure a match with the common an SI unit, select D0 and order DIN rail length
the maximum number of solenoids of the
specifications of the value to be used. separately, referring to L3 in the dimensions.
SI unit that will be mounted. If the layout is
Note 2) Without SI unit, the symbol is nil. Refer to page 140 for part numbers of DIN rail.
specified, indicate it on the manifold
specification sheet.

t P, E port entry
U Note) U side (2 to 10 stations)
D Note) D side (2 to 10 stations)
B Both sides (2 to 24 stations)
Note) y For type “S”, supply/exhaust block
assembly with built-in silencer, choose U or
D for P port entry.

Refer to Fieldbus System (CAT.E02-25) for details on the EX260


Integrated-type (For Output) Serial Transmission System.

107
Plug-in Connector Connecting Base Series SY3000/5000

Construction Specifications
How to Order Manifold Assembly

Replacement
Example (SS5Y3-12SNAN-쏔)

Parts
2-position single (24 VDC) 2-position double (24 VDC) SS5Y3-12SNAN-04D ····· 1 set (Type 12 4-station manifold base part no.)
SY3130-5U1-C6 (2 sets) SY3230-5U1-C6 (1 set)
∗SY3130-5U1-C6 ············· 2 sets (2-position single part no.)

Metal Base
3-position closed center (24 VDC) ∗SY3230-5U1-C6 ············· 1 set (2-position double part no.)

Plug-in
SY3330-5U1-C6 (1 set) ∗SY3330-5U1-C6 ············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.

Flat Ribbon Cable


D-sub Connector
• The valve arrangement is numbered as the 1st station from the D side.

PC Wiring
• Under the manifold part number, state the valves to be mounted in

de
si
order from the 1st station as shown in the figure above.

U
s
n
If the arrangement becomes complicated, specify on a manifold
tio

EX510
ta
S
specification sheet.
3
2

Refer to the SY3000/5000 series catalog


1
de

Manifold base (4 stations) page 8 for details on valve specifications.


si
D

SS5Y3-12SNAN-04D

Terminal D-sub Connector Plug-in Connector


Connecting Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


Block Box PC Wiring
q w e r t y u i o !0 !1 !2 !3
Top ported
A, B port size
Series Pilot valve option Thread piping
3 SY3000 Standard (0.7 MPa) Symbol Port size Applicable series

Lead Wire
5 SY5000 Quick response type (0.7 MPa) M5 M5 x 0.8 SY3000
High pressure type (1.0 MPa) 01 1/8 SY5000
Type of actuation
∗ Only metal seal type is available for the high pressure type. One-touch fitting (Metric)
2-position single

Connector
Coil type Symbol A and B port SY3000 SY5000

Circular
2-position double
C2 ø2 One-touch fitting
3-position closed center Nil Standard
C3 ø3.2 One-touch fitting
3-position exhaust center T With power saving circuit (Continuous duty type)
C4 ø4 One-touch fitting

EX120 EX126 EX260 EX250 EX600 EX500


3-position pressure center ∗ Be sure to select the power saving circuit type C6 ø6 One-touch fitting
4-position dual 3-port valve (N.C./N.C.) when a valve is continuously energized for
C8 ø8 One-touch fitting
4-position dual 3-port valve (N.O./N.O.) long periods of time.
4-position dual 3-port valve (N.C./N.O.) ∗ Note the specified energizing time when power One-touch fitting (Inch)
∗ Only rubber seal type is available for the 4-position dual 3-port valve. saving circuit is selected. Refer to page 154. Symbol A and B port SY3000 SY5000
N1 ø1/8" One-touch fitting
Seal type Rated voltage N3 ø5/32" One-touch fitting
0 Rubber seal 5 24 VDC N7 ø1/4" One-touch fitting
1 Metal seal N9 ø5/16" One-touch fitting
Light/surge voltage suppressor
Pilot type Thread type
and common specification
Nil Internal pilot Nil Rc
R With surge voltage suppressor (Non-polar)
R External pilot F G
U With light/surge voltage suppressor (Non-polar)
Back pressure check valve S With surge voltage suppressor (Positive common) N NPT
(Built-in valve type) Z With light/surge voltage suppressor (Positive common) T NPTF
Nil None NS With surge voltage suppressor (Negative common) ∗ Only Nil is available for M5.
H Built-in NZ With light/surge voltage suppressor (Negative common)
Type of mounting screw
∗ Only rubber seal type. ∗ Select a valve from R, U, S or Z when the SI unit
output polarity is Nil (Positive common). Nil Round head combination screw
Manifold installed type is available if the back
Select a valve from R, U, NS or NZ when the SI unit B Hexagon socket head cap screw
pressure check valve is required for a valve with output polarity is N (Negative common).
metal seal. Refer to page 147 for details. However, Round head combination screw
it is not recommended to use the built-in valve type
∗ Only “Z” and “NZ” types are available for the product K (Falling-out-prevention type)
with power saving circuit.
and the manifold installed type at the same time Hexagon socket head cap screw
and Plug Assembly/
One-touch Fittings

because it will reduce the flow. H


∗ The built-in valve type back pressure check valve is !0 Manual override (Falling-out-prevention type)
∗ For “K” and “H”, the valve body cover has a drop prevention
Part No.

not available for the 3-position type. Nil: Non-locking D: Push-turn F: Slide locking
construction to stop the mounting screws from falling out when
push type locking slotted type
the valve is removed for maintenance etc.
type
Manifold

∗ When ordering a valve individually, the base gasket is not included.


Options

Since the base gasket is attached to the manifold, please order the
base gasket separately if it is needed for maintenance service.
Refer to page 136 for part numbers of the base gasket and
mounting screw.
∗ “B” and “H” cannot be selected for the individual SUP/EXH spacer
Specific Product

assembly.
Precautions

Protective class
class # (Mark: )
108
Type 10 Plug-in Connector Connecting Base
Side Ported EX126

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 10 S4 V 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series Valve stations P, E port entry


3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring Note 1) B Both sides (2 to 16 stations)
08 8 stations
02 2 stations
Type Specified layout Note 2)
10 Side ported (Available up to 16 solenoids) SUP/EXH block assembly
16 16 stations
11 Bottom ported∗ Nil Internal pilot
Note 1) Double wiring: 2-position single, double, 3-
∗ The SY5000 manifold base is used for the position and 4-position valves can be S Internal pilot, Built-in silencer
bottom ported of the SY3000. When ordering, used on all manifold stations. R External pilot
refer to Plug-in Mixed Mounting Type Manifold Use of a 2-position single solenoid will ∗ 3/5(E) port is plugged for the built-in silencer
(from page 127). result in an unused control signal. If this is type.
not desired, order with a specified layout. ∗ When the built-in silencer type is used, keep
Note 2) Specified layout: Indicate the wiring the exhaust port from coming in direct contact
SI unit specifications with the manifold with water or other liquids.
0 Without SI unit specification sheet. (Note that 2-position
V CC-Link (Positive common NPN) double, 3-position and 4-position valves
cannot be used where single wiring has Refer to the page on the right for .
∗ Only a terminal block plate is mounted for the
been specified.)
valve without SI unit.
Note 3) This also includes the number of blanking
plate assembly. Mounting and Option
Symbol Mounting Option
How to Order Manifold Assembly None
Direct
Name plate (With station number)
mounting
Example (SS5Y3-10S4V-쏔-쏔) Name plate (Without station number)
2-position double (24 VDC) Without name plate
DIN rail
2-position single (24 VDC) SY3200-5U1 (1 set) Name plate (With station number)
mounting
SY3100-5U1 (3 sets) Name plate (Without station number)
3-position closed
SI unit center (24 VDC)
Note 1) Enter the number of stations inside 첸.
SY3300-5U1 (1 set)
(Refer to “DIN Rail Option” below.)
Note 2) Only direct mounting is available for Type
11 (Bottom ported).
DIN Rail Option
ide
Nil Direct mounting
Us 0 Without DIN rail (with bracket)
s

3 For 3 stations
n
tio

Specify a longer rail than the


ta
S

total length of specified stations.


2 3 16 For 16 stations
1
e
D sid
Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
Terminal block plate assembly Electric Products (CAT.E150) for details on the EX126 Integrated-type
Manifold base (5 stations) (For Output) Serial Transmission System.
SS5Y3-10S4V-05D-C6

SS5Y3-10S4V-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1 ··················· 3 sets (2-position single part no.)
∗SY3200-5U1 ··················· 1 set (2-position double part no.)
∗SY3300-5U1 ··················· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 114.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
109
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port (Metric) A, B port (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
Symbol A, B port Symbol A, B port

Flat Ribbon Cable


D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 ø6 One-touch fitting 쎲 쎲 — LN9 ø5/16" One-touch fitting — 쎲 —

Elbow
L8 ø8 One-touch fitting — 쎲 — BN3 ø5/32" One-touch fitting 쎲 — —
Elbow

B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —


B6 쎲 쎲 BN9 쎲

Flat Ribbon Cable


ø6 One-touch fitting — ø5/16" One-touch fitting — —
B8 ø8 One-touch fitting — 쎲 — LM∗
Elbow port, mixed sizes

Block Box PC Wiring


(Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the size on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting

Lead Wire
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000
Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
4 3-position exhaust center pressure type.
5 3-position pressure center
Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.)
B∗ 4-position dual 3-port valve (N.O./N.O.) Nil Standard
C∗ 4-position dual 3-port valve (N.C./N.O.) T With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve.
when the valve is continuously energized for Type of mounting screw
Seal type long periods of time.
Nil Round head combination screw
∗ Note the specified energizing time when power
0 Rubber seal saving circuit is selected. Refer to page 154. B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot drop prevention construction to stop the
R External pilot mounting screws from falling out when the
Light/surge voltage suppressor
valve is removed for maintenance etc.
and Plug Assembly/
One-touch Fittings

Back pressure check valve and common specification ∗ When ordering a valve individually, the base
(Built-in valve type) R With surge voltage suppressor (Non-polar) gasket is not included. Since the base gasket
Part No.

U With light/surge voltage suppressor (Non-polar) is attached to the manifold, please order the
Nil None
S With surge voltage suppressor (Positive common) base gasket separately if it is needed for
H Built-in maintenance service.
Manifold

Z With light/surge voltage suppressor (Positive common)


Options

∗ Only rubber seal type. Manifold installed type Refer to page 136 for part numbers of base
is available if the back pressure check valve ∗ Only “Z” type is available for the product with gasket and mounting screw.
is required for a valve with metal seal. Refer power saving circuit. ∗ “B” and “H” cannot be selected for the individual
to page 147 for Ordering Example. However, SUP/EXH spacer assembly or double check spacer
it is not recommended to use the built-in valve assembly with residual pressure release valve.
Specific Product

type and the manifold installed type at the


Precautions

same time because it will reduce the flow.


∗ The built-in valve type back pressure check
valve is not available for the 3-position type.
110
Series SY3000/5000

Dimensions: Type 10/EX126/Series SY3000


U C2
SS5Y3-10S4쏔- Stations D - C3, N1 ( )
C4, N3 D B C6, N7
D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
Light/surge voltage suppressor (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 4(A) port side: Blue (For rubber seal)
DIN rail : Gray (For metal seal)
(For DIN rail mounting)
2(B) port side: Yellow

8
B A B A B A B A B A

5.5
35

92.6
14 A 14 A 14 A 14 A 14 A

83
116
42

80

60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B
36.6

4.6
1.7
11

)
(4.9)

15.4
55.4 4 x M4

C6: 3.6
N7: 7.4
mounting hole
2 x M5 mounting hole (Fitting for the type with P/E
1
7.1 88.2 ( L2 1.5
ports on the U and/or D sides)

5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø8, ø5/16" [4(A), 2(B) port]
4 x G1/2 Applicable tube O.D.: ø2
SI unit
Signal/Electrical entry : ø3.2, ø1/8"
(Station 1)---(Station n) : ø4, ø5/32"
: ø6, ø1/4"
90.2

1 P 1 P
13.6
10.6

63.1
56.6
55.4

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18
13.2

(For DIN rail


mounting)

33.4
7.5

(Pitch)
Terminal block plate assembly
11.8

107.1 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10S4쏔-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

111
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/EX126/Series SY5000

Replacement
U C4, N3
SS5Y5-10S4쏔- Stations D - C6, N7 (D)

Parts
B C8, N9

Metal Base
D side U side

Plug-in
Manual override Note 2)
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting)

Flat Ribbon Cable


4(A) port side: Blue (For rubber seal)

D-sub Connector
DIN rail Light/surge voltage suppressor : Gray (For metal seal)

PC Wiring
2(B) port side: Yellow

EX510
8
B A B A B A B A B A

5.5
35
14 A 14 A 14 A 14 A 14 A
121.4
116
42

97.5
113.4

Terminal D-sub Connector Plug-in Connector


80

Connecting Base
81.2
61.7
5.5
42.4

12 B 12 B 12 B 12 B 12 B

Flat Ribbon Cable


1
16.4

10.9
4.7

Block Box PC Wiring


(5.9)

55.4
(8.3)

2 x M5 mounting hole 4 x M5 mounting hole


(Fitting for the type with P/E
7.1 87.7 L2 1.5
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)

Lead Wire
L3

Connector
Circular
One-touch fitting
[1(P), 3/5(E) port]
One-touch fitting
Applicable tube O.D.: ø10, ø3/8"
[4(A), 2(B) port]

EX120 EX126 EX260 EX250 EX600 EX500


4 x G1/2 SI unit (Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
Signal/Electrical entry
: ø6, ø1/4"
: ø8, ø5/16"
90.2

14.1

1 P 1 P
73.2
8.7

2 B2 B2 B2 B2 B
56.6
55.4

3/5 3/5
33.4

E E
29.1

4 A4 A4 A4 A4 A
13.2
12.4

(For DIN rail

33.4
mounting)
7.5

(Pitch)
Terminal block plate assembly (20.5)
11.8

108.8 18 P = 16

Note 1) These figures show the “SS5Y5-10S4쏔-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.
Manifold

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Options

L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5
Specific Product

L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425
Precautions

L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15

112
Plug-in Connector Connecting Base
EX126

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12S4 V 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Series Valve stations P, E port entry


3 SY3000 Symbol Stations Note U Note) U side (2 to 10 stations)
5 SY5000 02 2 stations D Note) D side (2 to 10 stations)
Double wiring Note 1) B Both sides (2 to 16 stations)
08 8 stations Note) t For type “S”, supply/exhaust block
02 2 stations assembly with built-in silencer, choose U
Specified layout Note 2)
SI unit or D for P port entry.
(Available up to 16 solenoids)
0 Without SI unit 16 16 stations
V CC-Link (Positive common NPN) Note 1) Double wiring: 2-position single, double, 3-
position and 4-position valves can be
∗ Only a terminal block plate is mounted for the SUP/EXH block assembly
used on all manifold stations.
valve without SI unit.
Use of a 2-position single solenoid will Nil Internal pilot
result in an unused control signal. If this is S Internal pilot, Built-in silencer
not desired, order with a specified layout. R External pilot
Note 2) Specified layout: Indicate the wiring
specifications on the manifold ∗ For built-in silencer type, P and E ports are
specification sheet. (Note that 2-position available on U and D sides. 3/5(E) port is
double, 3-position and 4-position valves plugged. The silencer exhaust port is located
cannot be used where single wiring has on the opposite side of P, E port entry.
been specified.) (Example: When the P, E port entry is D side,
Note 3) This also includes the number of blanking the silencer exhaust port is U side.)
plate assembly. ∗ When the built-in silencer type is used, keep
the exhaust port from coming in direct contact
with water or other liquids.

How to Order Manifold Assembly


P, E port size
Example (SS5Y3-12S4V-쏔-쏔) (One-touch fittings)
2-position double (24 VDC) Symbol SY3000 SY5000
2-position single (24 VDC) SY3230-5U1-C6 (1 set) Nil ø8 ø10
SY3130-5U1-C6 (3 sets) 3-position closed N ø5/16" ø3/8"
center (24 VDC) ∗ For N, sizes are in inches.
SI unit
SY3330-5U1-C6 (1 set)

Mounting
Nil Direct mounting
e D DIN rail mounting (With DIN rail)
U sid
D0 DIN rail mounting (Without DIN rail)
s

D3
n

For 3 stations
tio
ta

Specify a longer rail than


S

3
12 D16 For 16 stations
the standard length.
ide
Ds

Terminal block plate assembly


Manifold base (5 stations)
SS5Y3-12S4V-05D

SS5Y3-12S4V-05D ··· 1 set (Type 12 5-station manifold base part no.)


∗SY3130-5U1-C6········ 3 sets (2-position single part no.)
∗SY3230-5U1-C6········ 1 set (2-position double part no.)
∗SY3330-5U1-C6········ 1 set (3-position closed center part no.)
Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
The asterisk denotes the symbol for assembly. Electric Products (CAT.E150) for details on the EX126 Integrated-type
Prefix it to the part nos. of the valve, etc.
(For Output) Serial Transmission System.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

113
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Coil type Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Nil Standard C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center T With power saving circuit (Continuous duty type) C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center ∗ Be sure to select the power saving circuit type
C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center when the valve is continuously energized for C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) long periods of time. C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Note the specified energizing time when power One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) saving circuit is selected. Refer to page 154.
Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the 4- N1 ø1/8" One-touch fitting 쎲 —
position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage
5 24 VDC
N7 ø1/4" One-touch fitting 쎲 쎲

Connector
N9 ø5/16" One-touch fitting — 쎲

Circular
Seal type
0 Rubber seal
Light/surge voltage suppressor

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
and common specification
Nil Rc
R With surge voltage suppressor (Non-polar)
F G
U With light/surge voltage suppressor (Non-polar)
Pilot type N NPT
S With surge voltage suppressor (Positive common)
Nil T NPTF
Internal pilot Z With light/surge voltage suppressor (Positive common)
R External pilot ∗ Only “Z” types are available for models with a ∗ Only Nil is available for M5.
power saving circuit.

Back pressure check valve


(Built-in valve type)
!0 Manual override Type of mounting screw
Nil: Non-locking D: Push-turn F: Slide locking Nil Round head combination screw
Nil None
B Hexagon socket head cap screw
push type locking slotted type
H Built-in
K Round head combination screw (Falling-out-prevention type)
type
∗ Only rubber seal type. Manifold installed type H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve
is required for a valve with metal seal. Refer ∗ For “K” and “H”, the valve body cover has a
to page 147 for Ordering Example. However, drop prevention construction to stop the
it is not recommended to use the built-in valve mounting screws from falling out when the
type and the manifold installed type at the valve is removed for maintenance etc.
same time because it will reduce the flow. ∗ When ordering a valve individually, the base
∗ The built-in valve type back pressure check gasket is not included. Since the base gasket
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of base
and Plug Assembly/
One-touch Fittings

gasket and mounting screw.


∗ “B” and “H” cannot be selected for the individual
Part No.

SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

114
Type 10 Plug-in Connector Connecting Base
Side Ported EX120

SY3000/5000
Type 11
Bottom Ported
Series RoHS
How to Order Manifold

SS5Y 3 10 S3 R1 05 U C6
Refer to page 123 for dimensions
of Type 11/Bottom ported type.

Series Valve stations P, E port entry


3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring Note 1) B Both sides (2 to 16 stations)
08 8 stations
Type 02 2 stations
Specified layout Note 2)
10 Side ported
(Available up to 16 solenoids)
11 Bottom ported∗ 16 16 stations SUP/EXH block assembly
∗ The SY5000 manifold base is used for the Note 1) Double wiring: 2-position single, double, 3- Nil Internal pilot
bottom ported of the SY3000. When ordering, position and 4-position valves can be used S Internal pilot, Built-in silencer
refer to Plug-in Mixed Mounting Type Manifold on all manifold stations. R External pilot
(from page 127). Use of a 2-position single solenoid will
result in an unused control signal. If this is ∗ 3/5(E) port is plugged for the built-in silencer
not desired, order with a specified layout. type.
SI unit
Note 2) Specified layout: Indicate the wiring
0 Without SI unit
specifications on the manifold Refer to the page on the right for .
Q DeviceNet™ (Positive common NPN)
specification sheet. (Note that 2-position
R1 OMRON Corp.: CompoBus/S (16 outputs) (Positive common NPN) double, 3-position and 4-position valves
R2 OMRON Corp.: CompoBus/S (8 outputs) (Positive common NPN) cannot be used where single wiring has
V CC-Link (Positive common NPN) been specified.) Mounting and Option
ZB CompoNet™ (Positive common NPN) Note 3) This also includes the number of blanking Symbol Mounting Option
ZBN CompoNet™ (Negative common PNP) plate assembly. None
Note 4) Since R2 type SI unit has 8 outputs, note Direct
Note) Ensure a match with the common Name plate (With station number)
mounting
that up to 8 solenoids can be accommo- Name plate (Without station number)
specifications of the value to be used.
dated. Without name plate
How to Order Manifold Assembly DIN rail
Name plate (With station number)
mounting
Name plate (Without station number)
Example (SS5Y3-10S3쏔-쏔) Note 1) Enter the number of stations inside 첸.
(Refer to “DIN Rail Option” below.)
2-position double (24 VDC)
Note 2) Only direct mounting is available for
2-position single (24 VDC) SY3200-5U1 (1 set)
Type 11 (Bottom ported).
SY3100-5U1 (3 sets) 3-position closed
center (24 VDC) DIN Rail Option
SY3300-5U1 ( 1set) Nil Direct mounting
0 Without DIN rail (with bracket)
3 For 3 stations
Specify a longer rail than the
total length of specified stations.
16 For 16 stations
∗ If the DIN rail must be mounted without an SI
ide
Us unit, select D0. Then, refer to L3 of the dimen-
sions for the DIN rail length and order sepa-
s
n
tio
ta

rately. (Refer to page 140 for the DIN rail part


S

3 number.)
12
e
Manifold base (5 stations) D sid Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
SS5Y3-10S3V-05D-C6 Electric Products (CAT.E150) for details on the EX120 Integrated-
type (For Output) Serial Transmission System.
SS5Y3-10S3V-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ··················· 3 sets (2-position single part no.)
∗SY3200-5U1 ··················· 1 set (2-position double part no.)
∗SY3300-5U1 ··················· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 120.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
115
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
Symbol A, B port Symbol A, B port

Flat Ribbon Cable


D-sub Connector
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000

PC Wiring
C2 ø2 One-touch fitting 쎲 — — N1 ø1/8" One-touch fitting 쎲 — —
C3 ø3.2 One-touch fitting 쎲 — — N3 ø5/32" One-touch fitting 쎲 쎲 쎲

Straight
Straight

EX510
C4 ø4 One-touch fitting 쎲 쎲 쎲 N7 ø1/4" One-touch fitting 쎲 쎲 쎲
C6 ø6 One-touch fitting 쎲 쎲 쎲 N9 ø5/16" One-touch fitting — 쎲 쎲
C8 ø8 One-touch fitting — 쎲 쎲 CM∗ Straight port, mixed sizes 쎲 쎲 쎲
CM∗ Straight port, mixed sizes 쎲 쎲 쎲 LN3 ø5/32" One-touch fitting 쎲 — —

Downward Upward

Terminal D-sub Connector Plug-in Connector


Connecting Base
L4 ø4 One-touch fitting 쎲 쎲 — LN7 ø1/4" One-touch fitting 쎲 쎲 —
Downward Upward

L6 쎲 쎲 쎲

Elbow Note)
ø6 One-touch fitting — LN9 ø5/16" One-touch fitting — —
L8 쎲 쎲
Elbow Note)

ø8 One-touch fitting — — BN3 ø5/32" One-touch fitting — —


B4 ø4 One-touch fitting 쎲 쎲 — BN7 ø1/4" One-touch fitting 쎲 쎲 —
B6 쎲 쎲 BN9 쎲

Flat Ribbon Cable


ø6 One-touch fitting — ø5/16" One-touch fitting — —
B8 ø8 One-touch fitting — 쎲 — LM∗
Elbow port, mixed sizes

Block Box PC Wiring


(Including upward and downward piping)
쎲 쎲 —
Elbow port, mixed sizes
LM∗ (Including upward and downward piping) 쎲 쎲 — P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 141 to 143).
∗ Indicate the size on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting

Lead Wire
direction.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Connector
SY 3 1 0 0 5 1

Circular
EX120 EX126 EX260 EX250 EX600 EX500
Series
3 SY3000 Base mounted
5 SY5000
Pilot valve option Manual override
Type of actuation Nil Standard (0.7 MPa) Nil: D: F:
1 2-position single B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
2 2-position double K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high slotted
3 3-position closed center type
4 3-position exhaust center pressure type.
5 3-position pressure center Coil type
A∗ 4-position dual 3-port valve (N.C./N.C.)
B∗ 4-position dual 3-port valve (N.O./N.O.)
Nil Standard
C∗ 4-position dual 3-port valve (N.C./N.O.)
T With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving circuit type
∗ Only rubber seal type is available for the 4-position dual 3-port valve.
when the valve is continuously energized for Type of mounting screw
Seal type long periods of time.
∗ Note the specified energizing time when power Nil Round head combination screw
0 Rubber seal saving circuit is selected. Refer to page 154. B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
Rated voltage H Hexagon socket head cap screw (Falling-out-prevention type)
Pilot type
5 24 VDC ∗ For “K” and “H”, the valve body cover has a
Nil Internal pilot drop prevention construction to stop the
R External pilot Light/surge voltage suppressor mounting screws from falling out when the
valve is removed for maintenance etc.
and Plug Assembly/

and common specification


One-touch Fittings

Back pressure check valve ∗ When ordering a valve individually, the base
(Built-in valve type) R With surge voltage suppressor (Non-polar) gasket is not included. Since the base gasket
Part No.

U With light/surge voltage suppressor (Non-polar) is attached to the manifold, please order the
Nil None
S With surge voltage suppressor (Positive common) base gasket separately if it is needed for
H Built-in maintenance service.
Z With light/surge voltage suppressor (Positive common)
Manifold
Options

∗ Only rubber seal type. Manifold installed type NS With surge voltage suppressor (Negative common) Refer to page 136 for part numbers of the
is available if the back pressure check valve base gasket and mounting screw.
is required for a valve with metal seal. Refer NZ With light/surge voltage suppressor (Negative common)
∗ "B" and "H" cannot be selected for the
to page 147 for Ordering Example. However, ∗ Select a valve from R, U, S or Z unless the SI individual SUP/EXH spacer assembly or double
it is not recommended to use the built-in valve unit specification is ZBN (Negative common). check spacer assembly with residual pressure
Specific Product

type and the manifold installed type at the Select a valve from R, U, NS or NZ when the release valve.
Precautions

same time because it will reduce the flow. SI unit specification is ZBN (Negative common).
∗ The built-in valve type back pressure check ∗ Only “Z” and “NZ” types are available for the
valve is not available for the 3-position type. product with power saving circuit.
116
Series SY3000/5000

Dimensions: Type 10/EX120/Series SY3000


C2
U
SS5Y3-10S3쏔- Stations D - C3, N1
C4, N3 (D)
B C6, N7

D side U side
Manual override Note 2)
DIN rail holding screw (L5) L1
(For DIN rail mounting) (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
Light/surge voltage suppressor : Gray (For metal seal)
2(B) port side: Yellow

5.5
8
B A B A B A B A B A

92.6
14 A 14 A 14 A 14 A 14 A
64

35
83
6.2

60.5
40.9
12 B 12 B 12 B 12 B 12 B

M3
Terminal screw
16.1

4.6
4.6

1.7
)
(4.9)
C6: 3.6
N7: 7.4
4 x M4 mounting hole
(
(Fitting for the type with P/E
27.9 L2 1.5
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
One-touch fitting
(Station 1)---(Station n) : ø3.2, ø1/8"
[1(P), 3/5(E) port]
: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16"
: ø6, ø1/4"

1 P 1 P
10.6
13.6

63.1
56.6
61

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
7.5

(Pitch)
11.8

39.7 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10S3쏔-05D-C6”.


Note 2) Refer to page 121 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 124 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 96.9 107.4 117.9 128.4 138.9 149.4 159.9 170.4 180.9 191.4 201.9 212.4 222.9 233.4 243.9
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 123 135.5 148 160.5 173 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273
L4 112.5 125 137.5 150 162.5 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5
L5 13 14 15 16 17 12 13 14 15 16 17 11.5 12.5 13.5 14.5

117
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/EX120/Series SY5000

Replacement
U C4, N3
SS5Y5-10S3쏔- Stations D - C6, N7 (D)

Parts
B C8, N9

Metal Base
D side U side
Manual override Note 2)

Plug-in
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
M3 DIN rail Light/surge voltage suppressor : Gray (For metal seal)

Flat Ribbon Cable


D-sub Connector
Terminal screw 2(B) port side: Yellow

PC Wiring
8

5.5

EX510
6.2

BA BA BA BA BA
64

14 A 14 A 14 A 14 A 14 A

35
97.5

113.4

Terminal D-sub Connector Plug-in Connector


81.2

Connecting Base
61.7
36.9

5.5
12 B 12 B 12 B 12 B 12 B
10.9

4.7

Flat Ribbon Cable


(5.9)
(8.3)

Block Box PC Wiring


4 x M5 mounting hole

30.2 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

Lead Wire
One-touch fitting
[4(A), 2(B) port]

Connector
Applicable tube O.D.: ø4, ø5/32"

Circular
One-touch fitting (Station 1)----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

EX120 EX126 EX260 EX250 EX600 EX500


1 P 1 P
73.2

2 B2 B2 B2 B2 B
56.6
61

14.1
33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


7.5

mounting)

(Pitch)
11.8

44.2 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10S3쏔-05D-C8”.


Note 2) Refer to page 122 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 125 for dimensions of A or B port top-ported type.
and Plug Assembly/
One-touch Fittings

Part No.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Manifold
Options

L1 116.7 132.7 148.7 164.7 180.7 196.7 212.7 228.7 244.7 260.7 276.7 292.7 308.7 324.7 340.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373
Specific Product

L4 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5
Precautions

L5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16

118
Plug-in Connector Connecting Base
EX120

SY3000/5000
Type 12
Top Ported
Series RoHS
How to Order Manifold

SS5Y 3 12S3 R1 05 U
Refer to pages 124 and 125 for
dimensions of Type 12/Top ported type.

Valve stations P, E port entry


Series Symbol Stations Note U Note) U side (2 to 10 stations)
3 SY3000 02 2 stations D Note) D side (2 to 10 stations)
5 SY5000 Double wiring Note 1) B Both sides (2 to 16 stations)
08 8 stations Note) t For type “S”, supply/exhaust block
02 2 stations assembly with built-in silencer, choose U
Specified layout Note 2)
or D for P port entry.
(Available up to 16 solenoids)
SI unit 16 16 stations
0 Without SI unit Note 1) Double wiring: 2-position single, double,
Q DeviceNet™(Positive common NPN) 3-position and 4-position valves can be
R1 OMRON Corp.: CompoBus/S (16 outputs) (Positive common NPN) used on all manifold stations. SUP/EXH block assembly
R2 OMRON Corp.: CompoBus/S (8 outputs) (Positive common NPN) Use of a 2-position single solenoid will
Nil Internal pilot
V CC-Link (Positive common NPN) result in an unused control signal. If this is
not desired, order with a specified layout. S Internal pilot, Built-in silencer
ZB CompoNet™ (Positive common NPN) R External pilot
Note 2) Specified layout: Indicate the wiring
ZBN CompoNet™ (Negative common PNP)
specifications on the manifold ∗ For built-in silencer type, P and E ports are
Note 1) Ensure a match with the common specification sheet. (Note that 2-position available on U and D sides. 3/5(E) port is
specifications of the value to be used. double, 3-position and 4-position valves plugged. The silencer exhaust port is located
cannot be used where single wiring has on the opposite side of P, E port entry.
been specified.) (Example: When the P, E port entry is D side,
Note 3) This also includes the number of blanking the silencer exhaust port is U side.)
plate assembly.
Note 4) Since R2 type SI unit has 8 outputs, note
that up to 8 solenoids can be accommo-
dated. P, E port size
(One-touch fittings)
Symbol SY3000 SY5000
Nil ø8 ø10
How to Order Manifold Assembly N ø5/16" ø3/8"
∗ For N, sizes are in inches.
Example (SS5Y3-12S-쏔-쏔)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set) Mounting
2-position single (24 VDC)
3-position closed
Nil Direct mounting
SY3130-5U1-C6 (3 sets)
center (24 VDC) D DIN rail mounting (With DIN rail)
SY3330-5U1-C6 (1 set) D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations Specify a longer rail than
the standard length.
D16 For 16 stations
∗ When mounted on the DIN rail without the SI
e unit, please select D0 and refer to L3 of the
U sid dimensions for the DIN rail length, then order
separately. (Refer to page 140 for the DIN rail
s
n
tio
ta

part number.)
S

3
Manifold base 12
e
(5 stations)
D sid
SS5Y3-12S3V-05D

SS5Y3-12S3V-05D ··· 1 set (Type 12 5-station manifold base part no.)


∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.)
∗SY3330-5U1-C6 ······· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the valve, etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement Refer to Reduced Wiring Fieldbus System (Serial Transmission) in
becomes complicated, specify on a manifold specification sheet. Electric Products (CAT.E150) for details on the EX120 Integrated-type
(For Output) Serial Transmission System.

119
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


Coil type
2 2-position double C2 ø2 One-touch fitting 쎲 —
Nil

Block Box PC Wiring


Standard
3 3-position closed center C3 ø3.2 One-touch fitting 쎲 —
T With power saving circuit (Continuous duty type)
C4 ø4 One-touch fitting 쎲 쎲
4 3-position exhaust center
5 3-position pressure center ∗ Be sure to select the power saving circuit type C6 ø6 One-touch fitting 쎲 쎲
when the valve is continuously energized for 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) C8 ø8 One-touch fitting —
long periods of time.
B∗ 4-position dual 3-port valve (N.O./N.O.)
∗ Note the specified energizing time when power One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) saving circuit is selected. Refer to page 154. Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. N3 ø5/32" One-touch fitting 쎲 쎲
Rated voltage N7 ø1/4" One-touch fitting 쎲 쎲

Connector
5 24 VDC N9 ø5/16" One-touch fitting — 쎲

Circular
Seal type
0 Rubber seal

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Light/surge voltage suppressor Thread type
and common specification Nil Rc
R With surge voltage suppressor (Non-polar) F G
Pilot type U With light/surge voltage suppressor (Non-polar) N NPT
S With surge voltage suppressor (Positive common) T NPTF
Nil Internal pilot
Z With light/surge voltage suppressor (Positive common) ∗ Only Nil is available for M5.
R External pilot
NS With surge voltage suppressor (Negative common)
NZ With light/surge voltage suppressor (Negative common)
Back pressure check valve ∗ Select a valve from R, U, S or Z unless the SI
Type of mounting screw
(Built-in valve type) unit specification is ZBN (Negative common).
Select a valve from R, U, NS or NZ when the Nil Round head combination screw
Nil None
SI unit specification is ZBN (Negative common). B Hexagon socket head cap screw
H Built-in ∗ Only “Z” and “NZ” types are available for the K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type product with power saving circuit. H Hexagon socket head cap screw (Falling-out-prevention type)
is available if the back pressure check valve
is required for a valve with metal seal. Refer ∗ For “K” and “H”, the valve body cover has a
to page 147 for Ordering Example. However, drop prevention construction to stop the
it is not recommended to use the built-in valve !0 Manual override mounting screws from falling out when the
type and the manifold installed type at the Nil: Non-locking D: Push-turn F: Slide locking valve is removed for maintenance etc.
same time because it will reduce the flow. push type locking slotted type ∗ When ordering a valve individually, the base
∗ The built-in valve type back pressure check gasket is not included. Since the base gasket
type
valve is not available for the 3-position type. is attached to the manifold, please order the
base gasket separately if it is needed for
maintenance service.
Refer to page 136 for part numbers of the
and Plug Assembly/
One-touch Fittings

base gasket and mounting screw.


∗ “B” and “H” cannot be selected for the individual
Part No.

SUP/EXH spacer assembly.


Manifold
Options
Specific Product
Precautions

120
Series SY3000/5000

Dimensions: Type 10/External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override/Series SY3000
U
SS5Y3-10쏔- Stations D (S, R)- LB쏔
B
D side U side
One-touch fitting 7.4 85.5
[PE: Pilot EXH port] (For 5 stations)
[X: External pilot port]
(73.2) (7.4) (11.6)
Applicable tube O.D.: ø4, ø5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)

5.3
PE PE
LOCK

X X
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A

(127.8)
58.5
FREE

40.9
1P 1P
12 B 12 B 12 B 12 B 12 B

11.6

6.9
1.7

17.3
27.6
35.2
2(B) port (Fitting for the type with P/E
ports on the U and/or D sides)
70.6 1(P) port 4(A) port
3/5(E) port
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2
Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
(Station 1)---(Station n)
External pilot for straight piping
P, E port entry: D

manual override)
7.4 85.5

(Slide locking
1 P
(For 5 stations)
(65.4)

68.8
63.1
56.6
(43.2)

3/5 E

PE
LOCK

X
B A B A B
14 A 14 A 14

)
)
L6 : 32.4
LN7 : 34.9
L6 : 43.4
LN7 : 45.9
(Pitch)
FREE

(42.8)
(37.5)

1P
12 B 12 B
15.5 P= 10.5 (17.8) (
Note) These figures show the “SS5Y3-10F2-05DR-L6”.
(
78.6 One-touch fitting
82.3 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32"

Built-in silencer Downward (Type B)


<Internal pilot>
[SUP/EXH block] [Valve]
P, E port entry: D

Silencer (Exhaust port)


(Built-in silencer specification)
LOCK

LOCK
FREE

FREE
LOCK

B A B A B (11.2)
14 A 14 A 14

4(A) port
3/5(E) port
FREE

12 B 12 B
2(B) port

1(P) port
(0.2)
(7.2) (15)
Plug

121
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 10/External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override/Series SY5000

Replacement
U
SS5Y5-10쏔- Stations D (S, R)- LB쏔 D side U side

Parts
One-touch fitting
B 118.2
[PE: Pilot EXH port]
[X: External pilot port] (For 5 stations)
(65.4) (12)

Metal Base
Applicable tube O.D.: ø4, ø5/32"
(Fitting for the type with P/E

Plug-in
LOCK
ports on the U and/or D sides)

PE PE
3/5 B A B A B A B A B A 3/5

Flat Ribbon Cable


D-sub Connector
26.9
14 A 14 A 14 A 14 A 14 A

113.4

PC Wiring
E E
FREE

X X
1 1

(159.5)

61.7

EX510
52.8
P P
12 B 12 B 12 B 12 B 12 B

17.9

4.7
12.6

Terminal D-sub Connector Plug-in Connector


28.6

Connecting Base
36.9

(Fitting for the type with P/E


2(B) port ports on the U and/or D sides)
1(P) port
External pilot for straight piping 4(A) port One-touch fitting
(118.2) 3/5(E) port

Flat Ribbon Cable


P, E port entry: D [4(A), 2(B) port]
(For 5 stations) One-touch fitting Applicable tube O.D.: ø4, ø5/32"

Block Box PC Wiring


(20°) : ø6, ø1/4"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8" : ø8, ø5/16"

PE
(Station 1)----------- (Station n)
LOCK

3/5 BA BA
14 A 14 A

E
FREE

Lead Wire
1

manual override)
(59.8)

(Slide locking
P
(31.7)

12 B 12 B 12 B

78.9
1 P
66.1
(59.8)

(54.3)

Connector
(39.3)
(38.8)

Circular
3/5 E
70.8 One-touch fitting
4 A4 A4 A4 A4 A
74.5 [PE: Pilot EXH port]
[X: External pilot port]

EX120 EX126 EX260 EX250 EX600 EX500


Applicable tube O.D.: ø4, ø5/32" (Pitch)
18 P = 16 (20.5)
Built-in silencer
P, E port entry: D
Silencer (Exhaust port)
Note) These figures show the “SS5Y5-10F2-05DR-L8”.
(Built-in silencer specification)
LOCK

BA BA
14 A 14 A
FREE

12 B 12 B 12 B

Valve/Series SY3000 (Mixed Mounting)


Plug Downward (Type B) Upward (Type U)

Downward (Type B)
[SUP/EXH block] [Valve]
LOCK

LOCK

One-touch fitting
[4(A), 2(B) port]
and Plug Assembly/
One-touch Fittings
FREE

FREE
LOCK

LOCK

Applicable tube O.D.: ø4, ø5/32"


( B6 : 10.7
BN7: 13.2 ) : ø6, ø1/4"
Part No.
FREE

FREE

6.5

16.9

Manifold
Options

4(A) port

2(B) port ( L6 : 32.9


LN7 : 35.4 )
( B6 : 9.7
)
Specific Product

BN7: 7.2
( L6 : 53.3
)
Precautions

(11.1) (3.9) LN7 : 55.8


(14) (7)

122
Series SY3000/5000

Dimensions: Type 11/All Wirings/Series SY5000


U
SS5Y5-11쏔- Stations D D side U side
B L2 1.5 Manual override

(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side: Yellow

4 x M5 mounting hole
LOCK
BA BA BA BA B A
14 A 14 A 14 A 14 A 14 A

97.5
FREE

5.5
12 B 12 B 12 B 12 B 12 B

10.9
External pilot
P, E port entry: D (118.2) (Station 1) ---------- (Station n)
Refer to page 122 for X or (For 5 stations)
(20°)
PE port entry.

manual override)
(Slide locking
78.9
73.2
LOCK

PE
3/5 B A B A

8.7
14 A 14 A

4.7
E
FREE

X
1
(59.8)

(9.5)
(12.9)

(Fitting for the type with P/E


(31.7)

12 B 12 B 12 B
ports on the U and/or D sides)

120.5
70.8 One-touch fitting
(For 5 stations)
74.5 [PE: Pilot EXH port]
[X: External pilot port] (Pitch)
18 P = 16 (20.5)
4.7

Applicable tube O.D.: ø4, ø5/32"

Built-in silencer
31.8

39.7

P, E port entry: D Silencer (Exhaust port) 3/5 E 3/5 E


(Built-in silencer specification) 2 B2 B2 B2 B2 B
18

15

1 P 1 P
4 A4 A4 A4 A4 A
LOCK

Cut dimensions for panel mounting


BA BA
14 A 14 A Refer to panel cut dimensions
for details.
FREE

One-touch fitting One-touch fitting


12 B 12 B 12 B [1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø10, ø3/8" Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
Plug

Panel cut dimensions

Note 1) These figures show the “SS5Y5-11F2-05D-C8”.


7

Note 2) Refer to the below pages for L2 dimensions and other dimensions that are
not specified in each wiring specification.
D-sub connector : P. 52
60

Flat ribbon cable : P. 54


97.5

Terminal block box: P. 62


Lead wire : P. 70
Circular connector : P. 78
EX500 : P. 86
EX600 : P. 93, 94
L2 EX250 : P. 100
4 x M5 mounting hole EX260 : P. 106
4 x ø5.5 EX126 : P. 112
EX120 : P. 118
123
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 12/All Wirings/Series SY3000

Replacement
U
SS5Y3-12쏔- Stations D (R)

Parts
B
D side U side
89.3

Metal Base
(For 5 stations) Light/surge voltage suppressor

Plug-in
One-touch fitting (External pilot) (Pitch) Manual override
16 P = 10.5
[PE: Pilot EXH port]
[X: External pilot port]
7.4 (15.3)
(
Push-turn locking slotted type:
Press, then rotate it. )
Applicable tube O.D.: ø4, ø5/32" 4(A) port side: Blue (For rubber seal)

Flat Ribbon Cable


D-sub Connector
(73.2) : Gray (For metal seal)

PC Wiring
2(B) port side: Yellow

EX510
5.3
PE PE
LOCK

X X
3/5E B A B A B A B A B A 3/5E

92.6
4A 4A 4A 4A 4A
15

11

Terminal D-sub Connector Plug-in Connector


60.5
58.5
FREE

Connecting Base
40.9

1P 1P
31.8

30.2
2B 2B 2B 2B 2B

1.7
One-touch fitting

(A/B port, side ported)


2 x M2.6
[1(P), 3/5(E) port]

Flat Ribbon Cable


2 x 4-40 UNC (Fitting for the type with P/E
Applicable tube O.D.: ø8, ø5/16"
[P, E port size: N]
) C6: 3.6
N7: 7.4
ports on the U and/or D sides)

Block Box PC Wiring


M5 x 0.8
[4(A), 2(B) port] One-touch fitting
(
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"

Lead Wire
: ø6, ø1/4"

(Station 1)---(Station n)

Connector
Circular
)C6: 77.3
N7: 81.1

1 P 1 P
(73.8)

EX120 EX126 EX260 EX250 EX600 EX500


3/5 E 2 B2 B2 B2 B2 B 3/5 E
(

4 A4 A4 A4 A4 A

Note 1) These figures show the “SS5Y3-12F2-05D”.


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E
port. Refer to page 121 for dimensions of silencer.
Note 3) Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector : P. 51
Flat ribbon cable : P. 53
Terminal block box: P. 61
Lead wire : P. 69
Circular connector : P. 77
EX500 : P. 85
EX600 : P. 91, 92
EX250 : P. 99
EX260 : P. 105
EX126 : P. 111
EX120 : P. 117
and Plug Assembly/
One-touch Fittings

Part No.
Manifold
Options
Specific Product
Precautions

124
Series SY3000/5000

Dimensions: Type 12/All Wirings/Series SY5000


U
SS5Y5-12쏔- Stations D (R)
B
D side U side
Light/surge voltage suppressor
123.6
(For 5 stations)

(Pitch) Manual override


78.9
(Slide locking
manual override)
5.4
21.1 P = 16 (17.4)
(5.4)
(
Push-turn locking slotted type:
Press, then rotate it. )
One-touch fitting (External pilot) 4(A) port side: Blue (For rubber seal)
(65.4) [PE: Pilot EXH port] : Gray (For metal seal)
[X: External pilot port] 2(B) port side: Yellow
Applicable tube O.D.: ø4, ø5/32"
26.5

PE PE
LOCK

BA BA BA BA B A
3/5 3/5
26.9

4A 4A 4A 4A 4A

113.4
116.7
E E
FREE

X X
1 1

81.2
61.7

01 : 16.2
C쏔 : 14.5
52.8

P P

47.3
39.5

2B 2B 2B 2B 2B

One-touch fitting (Fitting for the type with P/E


4.7

2.7

[1(P), 3/5(E) port] ports on the U and/or D sides)


2 x M2.6 Applicable tube O.D.: ø10, ø3/8" 1/8
[4(A), 2(B) port] One-touch fitting
2 x 4-40 UNC
[P, E port size: N] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

(Station 1)----------- (Station n)

(91.3)
76.9

1 P 1 P
(69.7)

2 B2 B2 B2 B2 B

3/5 E 3/5 E

4 A4 A4 A4 A4 A
(For DIN rail
mounting)
7.5
11.8

Note 1) These figures show the “SS5Y5-12F2-05D”.


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E
port. Refer to page 122 for dimensions of silencer.
Note 3) Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector : P. 52
Flat ribbon cable : P. 54
Terminal block box: P. 62
Lead wire : P. 70
Circular connector : P. 78
EX500 : P. 86
EX600 : P. 93, 94
EX250 : P. 100
EX260 : P. 106
EX126 : P. 112
EX120 : P. 118

125
Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
D-sub Connector Flat Ribbon Cable PC Wiring Terminal Block Box (IP67)
Type 10 Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67) EX600 (IP67)
Side Ported EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

SY3000/5000
Type 11
Bottom Ported
Series
The SY3000 can be mounted onto the
SY5000 size manifold. How to Order Manifold

Refer to page 130 for dimensions


of Type 11/Bottom ported type. SS5Y5 M 10 F 1 05 U C 8 6
Mixed Mounting Type
It is possible to mount the SY3000 size valves on all stations.
In this case, there is no need to fill in part in the order code.
However, the manifold block width should be 12.5 mm.

Type Connector type


10 Side ported Symbol Type Page
• With Lead wire
11 Bottom ported F D-sub connector (25 pins)
P Flat ribbon cable (26 pins) Lead wire length
PG Flat ribbon cable (20 pins) P. 49 1 0.6 m
PH Flat ribbon cable (10 pins) 2 1.5 m
J PC wiring (20 pins) 3 3m
T Terminal block box P. 59
L1 Lead wire 34 cores • With D-sub connector, Flat ribbon
L2 Lead wire 17 cores P. 67 cable and PC wiring
L3 Lead wire 9 cores Connector entry direction
M Circular connector P. 75
1 Upward
S쏔 Serial transmission: EX500 P. 83 2 Lateral
S6쏔 Serial transmission: EX600 P. 89
S쏔 Serial transmission: EX250 P. 97 ∗ It is not necessary to select the items above
S쏔 Serial transmission: EX260 P. 103 for the valve with terminal block box or with
S4쏔 Serial transmission: EX126 P. 109 circular connector or the serial transmission
S3쏔 Serial transmission: EX120 P. 115 type.
∗ Refer to the pages shown in the table above Valve stations
for details.
Symbol Stations Note
02 2 stations Some connectors have a limitation
How to Order Manifold Assembly on the number of stations. Refer to
the pages shown in the table
24 24 stations “Connector type” for details.
Example (SS5Y5-M10F1-쏔)
2-position double
t P, E port entry y SUP/EXH block assembly
SY3200-5U1 (2 sets) U U side (2 to 10 stations) Nil Internal pilot
2-position double
SY5200-5U1 (3 sets)
D D side (2 to 10 stations) S Internal pilot, Built-in silencer
Manifold base (5 stations) B Both sides (2 to 24 stations) R External pilot
SS5Y5-M10F1-05D-C86
∗ Refer to page 89 for the EX600 and u ∗ 3/5(E) port is plugged for the
on page 97 for the EX250. built-in silencer type.
∗ Refer to page 89 for the EX600 and u
on page 97 for the EX250.

Refer to the page on the right for , and .


ide
Us

!0 Mounting and Option


s
n
tio
ta
S

3 Symbol Mounting Option


2
1 Nil None
ide AA
Direct
Ds mounting
Name plate (With station number)
BA Name plate (Without station number)
SS5Y5-M10F1-05D-C86 ··· 1 set (Type M10 5-station manifold base part no.) D첸 Without name plate
∗SY5200-5U1 ····················· 3 sets (2-position double part no.) DIN rail
A첸 mounting
Name plate (With station number)
∗SY3200-5U1 ····················· 2 sets (2-position double part no.) B첸 Name plate (Without station number)
The asterisk denotes the symbol for assembly. Note 1) Enter the number of stations inside 첸. (Refer to “DIN Rail Option” below.)
Prefix it to the part nos. of the valve, etc. Note 2) Only direct mounting is available for Type 11 (Bottom ported).
• The valve arrangement is numbered as the 1st station from the D side. DIN Rail Option
• Under the manifold part number, state the valves to be mounted in order Nil Direct mounting
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
0 Without DIN rail (with bracket)
3 For 3 stations Specify a longer rail than the total length of specified stations.
Note) When mixing top ported configurations, select from page 132. [The SY5000 valve is now at a mountable
In this case, use caution as there is also output on the A and B port on base side.
24 For 24 stations length (manifold block length of 16 mm).]
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side. ∗Refer to page 129 to determine the L3 using “Calculation formula” for the DIN rail length.
127
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
Plug-in
Fitting type SY5000: A, B port size

Flat Ribbon Cable


Symbol A, B port (Metric) (Inch)

D-sub Connector
C Metric size: Straight One-touch fitting Symbol Port size Symbol Port size

PC Wiring
L Metric size: One-touch fitting with upward elbow Note) 4 ø4 One-touch fitting 3 ø5/32" One-touch fitting
B Metric size: One-touch fitting with downward elbow Note) 6 ø6 One-touch fitting 7 ø1/4" One-touch fitting

EX510
N Inch size: Straight One-touch fitting 8 ø8 One-touch fitting 9 ø5/16" One-touch fitting
LN Inch size: One-touch fitting with upward elbow Note) Nil For all stations of SY3000 Nil For all stations of SY3000
BN Inch size: One-touch fitting with downward elbow Note) ∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected.
CM∗ Straight port, mixed sizes
SY3000: A, B port size

Terminal D-sub Connector Plug-in Connector


LM∗

Connecting Base
Elbow port, mixed sizes (Including upward and downward piping)
Note) To avoid interference with the body or piping, select downward elbow (Metric) (Inch)
port when mounting the optional spacer assembly (pages 141 to 143). Symbol Port size Symbol Port size
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, 2 ø2 One-touch fitting 1 ø1/8" One-touch fitting
“LM”. 3 ø3.2 One-touch fitting 3 ø5/32" One-touch fitting
∗ The direction of P, E port fittings is the same as for A, B port. If selecting 4 ø4 One-touch fitting 7 ø1/4" One-touch fitting

Flat Ribbon Cable


“LM”, indicate it on the manifold specification sheet for the P, E 6 ø6 One-touch fitting 9 ø5/16" One-touch fitting Note)

Block Box PC Wiring


port fitting direction. 8 ø8 One-touch fitting Note)
∗ Elbow fittings: ø2, ø3.2 and ø1.8" are not available for the SY3000 series.
ø2, ø3.2, ø1.8" and ø5/32" are not available for the SY5000 series. Note) The valve pitch is the same as the SY5000.
∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected.
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Lead Wire
SY 3 1 0 0 5 1

Connector
Circular
Base mounted
Series

EX120 EX126 EX260 EX250 EX600 EX500


Pilot valve option Manual override
3 SY3000 Nil Standard (0.7 MPa) Nil: D: F:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn Slide locking
Type of actuation K∗ High pressure type (1.0 MPa) push type locking type
∗ Only metal seal type is available for the high pressure type. slotted
1 2-position single type
2 2-position double Coil type
3 3-position closed center Nil Standard
4 3-position exhaust center T With power saving circuit (Continuous duty type)
5 3-position pressure center ∗ Be sure to select the power saving circuit type when the
A∗ 4-position dual 3-port valve (N.C./N.C.) valve is continuously energized for long periods of time.
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Note the specified energizing time when power saving
Type of mounting screw
C∗ 4-position dual 3-port valve (N.C./N.O.) circuit is selected. Refer to page 154.
Nil Round head combination screw
∗ Only rubber seal type is available for the 4-position dual 3-port valve.
Rated voltage B Hexagon socket head cap screw
Seal type 5 24 VDC K Round head combination screw (Falling-out-prevention type)
0 Rubber seal 6 12 VDC H Hexagon socket head cap screw (Falling-out-prevention type)
1 Metal seal ∗ Only 24 VDC is available for the serial transmission type. ∗ For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
Pilot type Light/surge voltage suppressor mounting screws from falling out when the
and common specification valve is removed for maintenance etc.
Nil Internal pilot
∗ When ordering a valve individually, the base
R External pilot Nil Without light/surge voltage suppressor (Non-polar) gasket is not included. Since the base gasket
R With surge voltage suppressor (Non-polar) is attached to the manifold, please order the
and Plug Assembly/
One-touch Fittings

Back pressure check valve U With light/surge voltage suppressor (Non-polar) base gasket separately if it is needed for
(Built-in valve type) S With surge voltage suppressor (Positive common) maintenance service.
Part No.

Nil None Z With light/surge voltage suppressor (Positive common) Refer to page 136 for part numbers of the
H Built-in NS With surge voltage suppressor (Negative common) base gasket and mounting screw.
∗ “B” and “H” cannot be selected for the individual
Manifold
Options

∗ Only rubber seal type. Manifold installed type NZ With light/surge voltage suppressor (Negative common) SUP/EXH spacer assembly or double check
is available if back pressure check valve is ∗ “Nil” is not available for the SI unit manifold. spacer assembly with residual pressure release
required for the valve with metal seal. Refer to ∗ Only “Z” and “NZ” types are available for the product valve.
page 147 for Ordering Example. However, it with power saving circuit. Select a valve which is suited
is not recommended to use the built-in valve to the SI unit output polarity or SI unit specification
Specific Product

type and the manifold installed type at the when the SI unit is selected.
Precautions

same time because it will reduce the flow. Refer to the pages below for details.
∗ The built-in valve type back pressure check EX500: P. 84 EX600: P. 90 EX250: P. 98
valve is not available for the 3-position type. EX260: P. 104 EX126: P. 110 EX120: P. 116

128
Series SY3000/5000

Dimensions: Type 10/Mixed Mounting


U
SS5Y5-M10쏔- Stations D D side U side
B Manual override
(L5) L1

DIN rail holding screw ( Push-turn locking slotted type:


Press, then rotate it. )
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail
(For DIN rail mounting)
Light/surge voltage suppressor
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side: Yellow

5.5
8
LOCK

B A B A B A B A B A

35
14 A 14 A 14 A 14 A 14 A

70.6
97.5

113.4
FREE

81.2
12 B 12 B
65.6

61.7
5.5
30.3

12 B 12 B
10.9

4 x M5

4.7
(5.9)
(8.3)
mounting hole
21.9 (Fitting for the type with P
L2 1.5
and E ports on both sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
One-touch fitting
(Station 1)--------- (Station n) [4(A), 2(B) port]
One-touch fitting
Compatible with mixed Applicable tube O.D.: ø2
[4(A), 2(B) port]
: ø3.2, ø1/8"
Applicable tube O.D.: ø4, ø5/32" mounting type: ø8, ø5/16"
: ø4, ø5/32"
: ø6, ø1/4" SY3000
: ø6, ø1/4"
: ø8, ø5/16"
6.1

manual override)
(SY3000)

(SY3000)

(Slide locking
11.1

31.5

78.9
1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6
48.6

8.7

3/5 3/5
33.4

E 4 A4 A4 A E
4 A4 A

14.1
(SY5000 and SY3000: ø8, ø5/16")
29.1
(SY5000 and SY3000: ø8, ø5/16")
12.4

(For DIN rail

One-touch fitting 35.9 18 (20.5)


mounting)

[1(P), 3/5(E) port]


7.5

Applicable tube O.D.: ø10, ø3/8" ( Pitch of


SY5000 ) ( Pitch of
SY3000 )
P = 16 P = 12.5
Calculation formula for dimensions with
D-sub connector, Flat ribbon cable and
PC wiring
( Pitch of SY3000: ø8,
ø5/16" ) One-touch fitting
[4(A), 2(B)port]
P = 16
Applicable tube O.D.: ø8, ø5/16"
L1 = 12.5 x n1 + 16 x n2 + 76.4
L2 = 12.5 x n1 + 16 x n2 + 48
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 Note) Refer to pages 121 and 122 for
L4 = L3 – 10.5
L5 = (L3 – L1 + 6.1)/2 dimensions of external pilot,
built-in silencer and elbow fittings.
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000
(Including the stations of the SY3000: ø8, ø5/16")

Calculation formula for dimensions with


Terminal block box, Lead wire, Circular
connector, EX500/600/250/260/126/120
serial transmission
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
L2 = 12.5 x n1 + 16 x n2 x 48
M = L1/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 Coefficient a b c
L4 = L3 – 10.5 Terminal block box or Serial transmission: EX126 149.3 — —
L5 = (L3 – L1)/2 Lead wire or Circular connector 97 — —
L6 = b x n3 + c
Serial transmission: EX500 88.5 — —
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000 Serial transmission: EX600 (M12 connector) 141.5 47 81.5
n3: Number of I/O units or input block stations Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Note) Refer to pages 91 to 94 for dimensions of the
EX600 serial transmission with I/O unit and Serial transmission: EX250 141.5 21 81.5
pages 99 and 100 for the EX250 serial Serial transmission: EX260 88.7 — —
transmission with input block when L6, b and
c are used for the calculation formula. Serial transmission: EX120 84.7 — —
129
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Dimensions: Type 11/Mixed Mounting

Replacement
U
SS5Y5-M11쏔- Stations D D side U side

Parts
B L1
Manual override

Metal Base
(Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
4(A) port side : Blue (For rubber seal) 4 x M5 mounting hole
: Gray (For metal seal)
2(B) port side : Yellow

Flat Ribbon Cable


D-sub Connector

PC Wiring
LOCK

B A B A B A B A B A

EX510
14 A 14 A 14 A 14 A 14 A

97.5
113.4
FREE

81.2
12 B 12 B

Terminal D-sub Connector Plug-in Connector


5.5

Connecting Base
12 B 12 B

10.9
21.9 L2 1.5

Flat Ribbon Cable


(Station 1)--------- (Station n)
Compatible with mixed

Block Box PC Wiring


mounting type: ø8, ø5/16"
Panel cut dimensions
SY3000

manual override)
(Slide locking
7

78.9
73.2

Lead Wire
60

97.5

4.7

Connector
(SY3000)

Circular
(SY5000)

(Fitting for the type with P


(12.9)

(7.3)
(9.5)

and E ports on both sides)


L2 4 x M5 mounting hole

EX120 EX126 EX260 EX250 EX600 EX500


(Pitch of SY3000: ø8, ø5/16")
4 x ø5.5 P=16
(Pitch of SY5000) (Pitch of SY3000)
P=16 P=12.5
4.7

35.9 18 (20.5)
)
SY5000 and

Calculation formula for dimensions


ø8, ø5/16"
31.8

SY3000:

(SY3000)
39.7

49.6

3/5
L1 = 12.5 x n1 + 16 x n2 + a + b x n3 3/5 E E
2 B2 B2 B
L2 = 12.5 x n1 + 16 x n2 + 48
) (
18

L6 = b x n3 + c 2 B2 B
Cut dimensions for panel mounting
(

Refer to panel cut dimensions 1 P 1 P


n1: Number of valve stations of the SY3000 4 A4 A4 A
(SY3000)

4 A4 A
SY5000 and

n2: Number of valve stations of the SY5000 for details.


ø8, ø5/16"
SY3000:

11

(Including the stations of the SY3000: ø8, ø5/16")


15

n3: Number of I/O units or input block stations


Note) Refer to pages 91 to 94 for dimensions One-touch fitting
(

of the EX600 serial transmission with [1(P), 3/5(E) port]


I/O unit and pages 99 and 100 for the Applicable tube O.D.: ø10, ø3/8" One-touch fitting
EX250 serial transmission with input [4(A), 2(B) port]
One-touch fitting Applicable tube O.D.: ø2
block when L6, b and c are used for
[4(A), 2(B) port] : ø3.2, ø1/8"
the calculation formula.
Applicable tube O.D.: ø4, ø5/32" : ø4, ø5/32"
: ø6, ø1/4" One-touch fitting : ø6, ø1/4"
: ø8, ø5/16" [4(A), 2(B) port]
and Plug Assembly/
One-touch Fittings

Applicable tube O.D.: ø8, ø5/16"


Coefficient a b c
Part No.

D-sub connector, Flat ribbon cable or PC wiring 74.6 — —


Terminal block box or Serial transmission: EX126 149.3 — —
Manifold

Lead wire or Circular connector 97 — —


Options

Serial transmission: EX500 88.5 — — Note) Refer to page 123 for dimensions of external pilots
Serial transmission: EX600 (M12 connector) 141.5 47 81.5 and built-in silencers, as well as their panel cuts.
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Specific Product

Serial transmission: EX250 141.5 21 81.5


Precautions

Serial transmission: EX260 88.7 — —


Serial transmission: EX120 84.7 — —
130
Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
D-sub Connector Flat Ribbon Cable PC Wiring Terminal Block Box (IP67)
Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67) EX600 (IP67)
EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

SY3000/5000
Type 12
Top Ported
Series
SY3000 can be mounted onto SY5000
size manifold. How to Order Manifold

Refer to pages 124 and 125 for


dimensions of Type 12/Top ported type. SS5Y5 M 12 F 1 05 U
Mixed Mounting Type
It is possible to mount the SY3000 size valves on all stations.
However, the manifold block width should be 12.5 mm.

Connector type Valve stations


Symbol Type Page Symbol Stations Note
• With Lead wire
F D-sub connector (25 pins) 02 2 stations Some connectors have a limitation
P Flat ribbon cable (26 pins) Lead wire length on the number of stations. Refer to
PG Flat ribbon cable (20 pins) P. 55 1 0.6 m the pages shown in the table
24 24 stations “Connector type” for details.
PH Flat ribbon cable (10 pins) 2 1.5 m
J PC wiring (20 pins) 3 3m
T Terminal block box P. 63
L1 Lead wire 34 cores • With D-sub connector, Flat ribbon P, E port entry
L2 Lead wire 17 cores P. 71 cable and PC wiring U Note) U side (2 to 10 stations)
L3 Lead wire 9 cores Connector entry direction D Note) D side (2 to 10 stations)
M Circular connector P. 79
1 Upward B Both sides (2 to 24 stations)
S쏔 Serial transmission: EX500 P. 87
2 Lateral ∗ Refer to page 95 for the EX600 and y on page
S6쏔 Serial transmission: EX600 P. 95 101 for the EX250.
S쏔 Serial transmission: EX250 P. 101 ∗ It is not necessary to select the items above Note) For type “S”, supply/exhaust block assembly
S쏔 Serial transmission: EX260 P. 107 for the valve with terminal block box or with with built-in silencer, choose U or D for P
S4쏔 Serial transmission: EX126 P. 113 circular connector or the serial transmission port entry.
S3쏔 Serial transmission: EX120 P. 119 type.
∗ Refer to the pages shown in the table above
for details. SUP/EXH block assembly
Nil Internal pilot
S Internal pilot, Built-in silencer
R External pilot
∗ For built-in silencer type, P and E ports are
How to Order Manifold Assembly available on U and D sides. 3/5(E) port is
plugged. The silencer exhaust port is located
on the opposite side of P, E port entry.
Example (SS5Y5-M12F1-쏔) (Example: When the P, E port entry is D side,
2-position double the silencer exhaust port is U side.)
2-position double
SY5230-5U1-C8 (3 sets) ∗ Refer to page 95 for the EX600 and y on page
SY3230-5U1-C6 (2 sets)
101 for the EX250.
Manifold base (5 stations)
SS5Y5-M12F1-05D

P, E port size
(One-touch fittings)
Nil ø10
e N ø3/8"
U sid
s
n
tio

Mounting
ta
S

3
2 Nil Direct mounting
1 D DIN rail mounting (With DIN rail)
ide
Ds D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations Specify a longer rail than the standard length.
SS5Y5-M12F1-05D ··· 1 set (Type M12 5-station manifold base part no.)
[The SY5000 valve is now at a mountable
∗SY5230-5U1-C8 ········ 3 sets (2-position double part no.)
D24 For 24 stations length (manifold block length of 16 mm).]
∗SY3230-5U1-C6 ········ 2 sets (2-position double part no.)
The asterisk denotes the symbol for assembly. ∗ Refer to page 133 to determine the L3 using “Calculation formula”
Prefix it to the part nos. of the valve, etc. for the DIN rail length.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

131
Series SY3000/5000

Construction Specifications
Plug-in Connector Connecting Base

Replacement
Parts
Metal Base
How to Order Valves (With two mounting screws) Refer to page 8 for valve specifications.

Plug-in
SY 3 1 3 0 5 1 C6

Flat Ribbon Cable


D-sub Connector

PC Wiring
EX510
Top ported

Series Pilot valve option A, B port size


3 SY3000 Nil Standard (0.7 MPa) Thread piping

Terminal D-sub Connector Plug-in Connector


Connecting Base
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
K∗ High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000
pressure type.
Type of actuation One-touch fitting (Metric)
1 2-position single Coil type Symbol A, B port SY3000 SY5000

Flat Ribbon Cable


2 2-position double Nil Standard C2 ø2 One-touch fitting 쎲 —

Block Box PC Wiring


3 3-position closed center T With power saving circuit (Continuous duty type) C3 ø3.2 One-touch fitting 쎲 —
4 3-position exhaust center ∗ Be sure to select the power saving circuit type C4 ø4 One-touch fitting 쎲 쎲
5 3-position pressure center when a valve is continuously energized for C6 ø6 One-touch fitting 쎲 쎲
A∗ 4-position dual 3-port valve (N.C./N.C.) long periods of time. C8 ø8 One-touch fitting — 쎲
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Note the specified energizing time when power
One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) saving circuit is selected. Refer to page 154.
Symbol A, B port SY3000 SY5000

Lead Wire
∗ Only rubber seal type is available for the N1 ø1/8" One-touch fitting 쎲 —
4-position dual 3-port valve. Rated voltage N3 ø5/32" One-touch fitting 쎲 쎲
5 24 VDC N7 ø1/4" One-touch fitting 쎲 쎲

Connector
6 12 VDC N9 ø5/16" One-touch fitting — 쎲

Circular
Seal type ∗ Only 24 VDC is available for the serial
0 Rubber seal transmission type.

EX120 EX126 EX260 EX250 EX600 EX500


1 Metal seal Thread type
Light/surge voltage suppressor Nil Rc
and common specification F G
Pilot type Nil Without light/surge voltage suppressor (Non-polar) N NPT
Nil Internal pilot R With surge voltage suppressor (Non-polar) T NPTF
R External pilot U With light/surge voltage suppressor (Non-polar) ∗ Only Nil is available for M5.
S With surge voltage suppressor (Positive common)
Z With light/surge voltage suppressor (Positive common)
Back pressure check valve NS With surge voltage suppressor (Negative common)
(Built-in valve type) Type of mounting screw
NZ With light/surge voltage suppressor (Negative common)
Nil None
Nil Round head combination screw
∗ “Nil” is not available for the SI unit manifold. B Hexagon socket head cap screw
H Built-in ∗ Only “Z” and “NZ” types are available for the
K Round head combination screw (Falling-out-prevention type)
∗ Only rubber seal type. Manifold installed type product with power saving circuit. Select a
is available if the back pressure check valve valve which is suited to the SI unit output H Hexagon socket head cap screw (Falling-out-prevention type)
is required for a valve with metal seal. Refer polarity or SI unit specification when the SI ∗ For “K” and “H”, the valve body cover has a
to page 147 for Ordering Example. However, unit is selected. drop prevention construction to stop the
it is not recommended to use the built-in valve Refer to the pages below for details. mounting screws from falling out when the
type and the manifold installed type at the EX500: P. 88 valve is removed for maintenance etc.
same time because it will reduce the flow. EX600: P. 96 ∗ When ordering a valve individually, the base
∗ The built-in valve type back pressure check EX250: P. 102 gasket is not included. Since the base gasket
valve is not available for the 3-position type. EX260: P. 108 is attached to the manifold, please order the
base gasket separately if it is needed for
EX126: P. 114
maintenance service.
EX120: P. 120
and Plug Assembly/

Refer to page 136 for part numbers of the


One-touch Fittings

base gasket and mounting screw.


∗ “B” and “H” cannot be selected for the individual
Manual override
Part No.

SUP/EXH spacer assembly.


Nil: D: F:
Manifold

Non-locking Push-turn Slide locking


Options

push type locking type


slotted
type
Specific Product
Precautions

132
Series SY3000/5000

Dimensions: Type 12/Mixed Mounting


U
SS5Y5-M12쏔- Stations D D side U side
B
(L5) L1

( Pitch of
SY5000 ) Manual override
32.8 21.1 P = 16
Light/surge voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )
78.9
(Slide locking manual override)
(
Pitch of
SY3000 ) 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
(65.4) P = 12.5
2(B) port side: Yellow

8
LOCK

PE
B A B A B A B A B A

5.5
3/5

35
4A 4A
4A 4A 4A

113.4
26.5
E
FREE

X
1

(SY3000)

81.2
(SY3000)
2B 2B

(SY5000)
61.7

11

56.4
01 : 16.2
C쏔: 14.5
(SY5000)
P

47.3
39.5

2B 2B 2B

2.7
4.7

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting One-touch fitting
Applicable tube O.D.: ø10, ø3/8" [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø2
: ø6, ø1/4" : ø3.2, ø1/8"
: ø8, ø5/16" : ø4, ø5/32"
5.3 L4 : ø6, ø1/4"
(DIN rail mounting hole pitch: 12.5)
L3

(Station 1)--------- (Station n)


(SY5000)

(SY3000)
(91.3)

(87.4)
1 P 1 P
(69.7)

2 B2 B2 B2 B2 B

3/5 E 4 A4 A4 A 3/5 E
4 A4 A
(For DIN rail
mounting)
7.5

Calculation formula for dimensions with Calculation formula for dimensions with
11.8

D-sub connector, Flat ribbon cable and Terminal block box, Lead wire, Circular
PC wiring connector, EX500/600/250/260/126/120
L1 = 12.5 x n1 + 16 x n2 + 76.4 serial transmission
L2 = 12.5 x n1 + 16 x n2 + 48 L1 = 12.5 x n1 + 16 x n2 + a + b x n3
Note) Refer to pages 121 and 122 for
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated. L2 = 12.5 x n1 + 16 x n2 x 48 dimensions of external pilot and
L3 = 12.5 x M + 23 M = L1/12.5 + 1 Decimal fractions are truncated. elbow fittings.
L4 = L3 – 10.5 L3 = 12.5 x M + 23
L5 = (L3 – L1 + 6.1)/2 L4 = L3 – 10.5
n1: Number of valve stations of the SY3000 L5 = (L3 – L1)/2
n2: Number of valve stations of the SY5000 L6 = b x n3 + c
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000
n3: Number of I/O units or input block stations
Note) Refer to pages 91 to 94 for dimensions of the EX600 serial transmission with I/O unit
and pages 99 and 100 for the EX250 serial transmission with input block when L6, b
and c are used for the calculation formula.
Coefficient a b c
Terminal block box or Serial transmission: EX126 149.3 — —
Lead wire or Circular connector 97 — —
Serial transmission: EX500 88.5 — —
Serial transmission: EX600 (M12 connector) 141.5 47 81.5
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —
133
Series SY3000/5000 Type 10, 11, 12

Construction Specifications
Plug-in Connector Connecting Base Manifold Exploded View

Replacement
@7 Tightening torque SY3000: 0.16 N·m U side
SY5000: 0.8 N·m

Parts
w a (Tightening torque:
0.8 N·m)

Metal Base
Plug-in
Flat Ribbon Cable
D-sub Connector
D side SUP blocking disk assembly
Refer to Manifold Options
@2

PC Wiring
on page 146. @3
@4

EX510
D-sub connector/ @6
Flat ribbon cable @8 It is mounted only for
the DIN rail mounting
Cover assembly type (with DIN rail.)
e

Terminal D-sub Connector Plug-in Connector


Connecting Base
Silencer cover assembly
Port block assembly
Refer to page 138. q

Flat Ribbon Cable


LOC EXH blocking disk assembly
K
@5 Refer to Manifold Options

Block Box PC Wiring


FRE
E
on page 146.
@9 It is mounted only for the DIN rail
mounting type.
(Tightening torque of
holding screw: 1.4 N·m)
@9 It is mounted only for the DIN rail mounting type.

Lead Wire
(The holding screw(s) of the clamping bracket is tightened at one
point for D-sub connector/Flat ribbon cable, EX120 and are
tightened at two points for EX500/600/250/260/126, Terminal block
box, Lead wire and Circular connector.)

Connector
(Tightening torque of holding screw: 1.4 N·m)

Circular
Holding screw
EX600 EX500 Terminal block box Lead wire

EX120 EX126 EX260 EX250 EX600 EX500


e e
i e y
r
o
e
!0 !3
!1
t Circular connector

!2 e
u

EX250 EX260 EX120 EX126


e e
@0
!4
e e
and Plug Assembly/

!5 !8
One-touch Fittings

!9
!6
Part No.

!7 @1 t
Manifold
Options
Specific Product
Precautions

134
Series SY3000/5000

Manifold Parts No.


Part no.
No. Description Note
SS5Y3-10/11/12 SS5Y5-(M)10/11/12
q Manifold block assembly Refer to page 137. Includes @2 (1 pc.), @3, @4, and @6.
w SUP/EXH end block assembly Refer to page 137.
e SUP/EXH block assembly Refer to page 137.
r Terminal block box housing assembly VVQC1000-T0-1
Clamp bracket assembly for terminal block box
t SY30M-15-4A Supplied individually.
Clamp bracket assembly for EX126 SI unit
SY30M-14-4A-1-1 34 cores, 0.6 m lead wire
SY30M-14-4A-1-2 34 cores, 1.5 m lead wire
SY30M-14-4A-1-3 34 cores, 3 m lead wire
SY30M-14-4A-2-1 17 cores, 0.6 m lead wire
y Lead wire connector block assembly SY30M-14-4A-2-2 17 cores, 1.5 m lead wire
SY30M-14-4A-2-3 17 cores, 3 m lead wire
SY30M-14-4A-3-1 9 cores, 0.6 m lead wire
SY30M-14-4A-3-2 9 cores, 1.5 m lead wire
SY30M-14-4A-3-3 9 cores, 3 m lead wire
u Circular connector block assembly SY30M-14-5A 26 pins
i Valve plate EX600-ZMV2 With mounting screws (2 pcs. of M4 x 6 and 2 pcs. of M3 x 8)
EX600-SDN1A DeviceNet™ PNP (Negative common)
EX600-SDN2A DeviceNet™ NPN (Positive common)
EX600-SMJ1 CC-Link PNP (Negative common)
EX600-SMJ2 CC-Link NPN (Positive common)
EX600-SPR1A PROFIBUS DP PNP (Negative common)
o EX600 SI unit
EX600-SPR2A PROFIBUS DP NPN (Positive common)
EX600-SEN1 EtherNet/IP™ PNP (Negative common)
EX600-SEN2 EtherNet/IP™ NPN (Positive common)
EX600-SEC1 EtherCAT PNP (Negative common)
EX600-SEC2 EtherCAT NPN (Positive common)
EX600-DXNB NPN input, M12 connector, 5 pins (4 pcs.), 8 inputs
EX600-DXPB PNP input, M12 connector, 5 pins (4 pcs.), 8 inputs
EX600-DXNC NPN input, M8 connector, 3 pins (8 pcs.), 8 inputs
EX600-DXNC1 NPN input, M8 connector, 3 pins (8 pcs.), 8 inputs, with open circuit detection
EX600-DXPC PNP input, M8 connector, 3 pins (8 pcs.), 8 inputs
EX600-DXPC1 PNP input, M8 connector, 3 pins (8 pcs.), 8 inputs, with open circuit detection
EX600 digital input unit
EX600-DXND NPN input, M12 connector, 5 pins (8 pcs.), 16 inputs
EX600-DXPD PNP input, M12 connector, 5 pins (8 pcs.), 16 inputs
EX600-DXNE NPN input, D-sub connector, 25 pins, 16 inputs
EX600-DXPE PNP input, D-sub connector, 25 pins, 16 inputs
EX600-DXNF NPN input, Spring type terminal block, 32 pins, 16 inputs
EX600-DXPF PNP input, Spring type terminal block, 32 pins, 16 inputs
!0 EX600-DYNB NPN output, M12 connector, 5 pins (4 pcs.), 8 outputs
EX600-DYPB PNP output, M12 connector, 5 pins (4 pcs.), 8 outputs
EX600-DYNE NPN output, D-sub connector, 25 pins, 16 outputs
EX600 digital output unit
EX600-DYPE PNP output, D-sub connector, 25 pins, 16 outputs
EX600-DYNF NPN output, Spring type terminal block, 32 pins, 16 outputs
EX600-DYPF PNP input/output, Spring type terminal block, 32 pins, 16 outputs
EX600-DMNE NPN input/output, D-sub connector, 25 pins, 8 inputs/outputs
EX600-DMPE PNP input/output, D-sub connector, 25 pins, 8 inputs/outputs
EX600 digital input/output unit
EX600-DMNF NPN input/output, Spring type terminal block, 32 pins, 8 inputs/outputs
EX600-DMPF PNP input/output, Spring type terminal block, 32 pins, 8 inputs/outputs
EX600 analog input unit EX600-AXA M12 connector, 5 pins (2 pcs.), 2-channel input
EX600 analog output unit EX600-AYA M12 connector, 5 pins (2 pcs.), 2-channel output
EX600 analog input/output unit EX600-AMB M12 connector, 5 pins (4 pcs.), 2-channel input/output
EX600-ED2 M12 connector, 5 pins, Max. supplied current 2 A
EX600-ED2-3 M12 connector, 5 pins, Max. supplied current 2 A, with DIN rail mounting bracket
!1 EX600 end plate
EX600-ED3 7/8 inch connector, 5 pins, Max. supplied current 8 A
EX600-ED3-3 7/8 inch connector, 5 pins, Max. supplied current 8 A, with DIN rail mounting bracket
!2 Clamp bracket for EX600 EX600-ZMA2 With mounting screws (1 pc. of M4 x 20 and 2 pcs. of M4 x 14)
EX500-Q001 DeviceNet™, PROFIBUS DP, CC-Link, EtherNet/IP™ (Positive common)
!3 EX500 SI unit
EX500-Q101 DeviceNet™, PROFIBUS DP, CC-Link, EtherNet/IP™ (Negative common)
EX250-SDN1 DeviceNet™ (Negative common)
EX250-SPR1 PROFIBUS DP (Negative common)
EX250-SMJ2 CC-Link (Positive common)
EX250-SAS3 AS-Interface, 8 in/8 out, 31 slave modes, 2 isolated common type (Negative common)
!4 EX250 SI unit EX250-SAS5 AS-Interface, 4 in/4 out, 31 slave modes, 2 isolated common type (Negative common)
EX250-SAS7 AS-Interface, 8 in/8 out, 31 slave modes, 1 common type (Negative common)
EX250-SAS9 AS-Interface, 4 in/4 out, 31 slave modes, 1 common type (Negative common)
EX250-SCA1A CANopen (Negative common)
EX250-SEN1 EtherNet/IP™ (Negative common)
EX250-IE1 M12, 2 inputs
!5 EX250 input block EX250-IE2 M12, 4 inputs
EX250-IE3 M8, 4 inputs
!6 EX250 end plate assembly EX250-EA1 With mounting screws (2 pcs. of M3 x 10)
!7 Clamp bracket assembly for EX250 SY30M-15-3A Supplied individually.
135
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Manifold Parts No.

Replacement
Part no.

Parts
No. Description Note
SS5Y3-10/11/12 SS5Y5-(M)10/11/12
EX260-SDN1 DeviceNet™ M12 connector, 32 outputs (Negative common) (PNP)

Metal Base
EX260-SDN2 DeviceNet™ M12 connector, 32 outputs (Positive common) (NPN)
EX260-SDN3 DeviceNet™ M12 connector, 16 outputs (Negative common) (PNP)

Plug-in
EX260-SDN4 DeviceNet™ M12 connector, 16 outputs (Positive common) (NPN)
EX260-SPR1 PROFIBUS DP M12 connector, 32 outputs (Negative common) (PNP)
EX260-SPR2 PROFIBUS DP M12 connector, 32 outputs (Positive common) (NPN)
EX260-SPR3 PROFIBUS DP M12 connector, 16 outputs (Negative common) (PNP)

Flat Ribbon Cable


D-sub Connector
EX260-SPR4 PROFIBUS DP M12 connector, 16 outputs (Positive common) (NPN)

PC Wiring
EX260-SPR5 PROFIBUS DP D-sub connector, 32 outputs (Negative common) (PNP)
EX260-SPR6 PROFIBUS DP D-sub connector, 32 outputs (Positive common) (NPN)
EX260-SPR7 PROFIBUS DP D-sub connector, 16 outputs (Negative common) (PNP)

EX510
EX260-SPR8 PROFIBUS DP D-sub connector, 16 outputs (Positive common) (NPN)
!8 EX260 SI unit
EX260-SMJ1 CC-Link M12 connector, 32 outputs (Negative common) (PNP)
EX260-SMJ2 CC-Link M12 connector, 32 outputs (Positive common) (NPN)
EX260-SMJ3 CC-Link M12 connector, 16 outputs (Negative common) (PNP)

Terminal D-sub Connector Plug-in Connector


Connecting Base
EX260-SMJ4 CC-Link M12 connector, 16 outputs (Positive common) (NPN)
EX260-SEC1 EtherCAT M12 connector, 32 outputs (Negative common) (PNP)
EX260-SEC2 EtherCAT M12 connector, 32 outputs (Positive common) (NPN)
EX260-SEC3 EtherCAT M12 connector, 16 outputs (Negative common) (PNP)
EX260-SEC4 EtherCAT M12 connector, 16 outputs (Positive common) (NPN)
EX260-SPN1 PROFINET 32 outputs (Negative common) (PNP)

Flat Ribbon Cable


EX260-SPN2 PROFINET 32 outputs (Positive common) (NPN)

Block Box PC Wiring


EX260-SPN3 PROFINET 16 outputs (Negative common) (PNP)
EX260-SPN4 PROFINET 16 outputs (Positive common) (NPN)
EX120-SDN1 DeviceNet™ (Positive common)
EX120-SCS1 OMRON Corp.: CompoBus/S (16 outputs) (Positive common)
EX120-SCS2 OMRON Corp.: CompoBus/S (8 outputs) (Positive common)
!9 EX120 SI unit
EX120-SMJ1 CC-Link (Positive common)
EX120-SCM1

Lead Wire
CompoNet™ (Positive common)
EX120-SCM3 CompoNet™ (Negative common)
@0 EX126 SI unit EX126D-SMJ1 CC-Link (Positive common)
@1 Terminal block plate assembly VVQC1000-74A-2 For mounting EX126 SI unit

Connector
@2 Base gasket (for connector connecting base) SY30M-9-1A SY50M-9-1A Part numbers shown on the left are for 10 valves. (10 pcs.)

Circular
@3 Connector gasket SX3000-146-2 Supplied individually.
@4 Manifold block gasket SY30M-9-2 SY50M-9-2 Supplied individually.
Tie-rod VVQ1000-TR-첸 SV2000-55-1-첸-A 첸: Manifold stations 2 pcs. supplied (SY3000), 3 pcs. supplied (SY5000)
@5

EX120 EX126 EX260 EX250 EX600 EX500


Tie-rod (for mounting only SY3000 on mixed mounting type manifolds) — SY50M-49-1-첸-A 3 pcs. supplied.
Tie-rod for additional stations SY30M-49-2-A SV2000-55-2A-A 2 pcs. supplied (SY3000), 3 pcs. supplied (SY5000) (Included in q)
@6 Tie-rod for additional stations (for mixed mounting of SY3000: except A, B port size ø8, ø5/16") — SY50M-49-2-A 3 pcs. supplied. (Included in q)
Tie-rod for additional stations (for mixed mounting of SY3000: A, B port size ø8, ø5/16") — SV2000-55-ZA-A 3 pcs. supplied.
Round head combination screw SY3000-23-24A SY5000-221-1A Part numbers shown on the left are for 10 valves. (20 pcs.)
Valve mounting (M2 x 32) (M3 x 32.5)
@7
screw SY3000-222-1A SY5000-222-1A
Hexagon socket head cap screw Part numbers shown on the left are for 10 valves. (20 pcs.)
(M2 x 32) (M3 x 32.5)
@8 DIN rail VZ1000-11-1-첸 Refer to page 140.
@9 Clamp bracket assembly (for connector connecting base) SY30M-15-1A SY50M-15-1A Supplied individually.

and Plug Assembly/


One-touch Fittings

Part No.
Manifold
Options
Specific Product
Precautions

136
Series SY3000/5000

Manifold Parts No.


qManifold block assembly
SY 0M 2 A A, B port size
Symbol A, B port SY3000 SY5000 Note Symbol A, B port SY3000 SY5000 Note
C2 ø2 One-touch fitting L4 ø4 One-touch fitting

Downward elbow Upward elbow


Side ported
Series Piping direction C3 ø3.2 One-touch fitting Side/Bottom L6 ø6 One-touch fitting
Metric size
3 SY3000 1 Side/Top ported C4 ø4 One-touch fitting ported L8 ø8 One-touch fitting Note)

5 SY5000 2 Bottom ported C6 ø6 One-touch fitting Metric size LN3 ø5/32" One-touch fitting
Side ported
C8 ø8 One-touch fitting Note) LN7 ø1/4" One-touch fitting
Metric size
N1 ø1/8" One-touch fitting LN9 ø5/16" One-touch fitting Note)
Side/Bottom
N3 ø5/32" One-touch fitting
ported
B4 ø4 One-touch fitting
Side ported
N7 ø1/4" One-touch fitting Inch size B6 ø6 One-touch fitting
Metric size
Single wiring N9 ø5/16" One-touch fitting Note) B8 ø8 One-touch fitting Note)
Marked with S Note) Refer to Mixed Mounting Type: ø8, ø5/16" BN3 ø5/32" One-touch fitting
Side ported
BN7 ø1/4" One-touch fitting
Metric size
Wiring type BN9 ø5/16" One-touch fitting Note)

S Single wiring 00 Plug Top ported


D Double wiring
qMixed mounting of the SY3000 and SY5000, Manifold
block assembly for mounting the SY3000 for ø8, ø5/16"
q Mixed mounting of the SY3000 and SY5000, (A manifold block assembly for mounting the SY3000 valves on the
Manifold block assembly for mounting the SY3000 SY5000 manifolds at A, B port size: ø8, ø5/16")
SY50M 2 A SY50M 2 A
Piping direction
Piping direction 5 Side ported Wiring type
3 Side/Top ported 6 Bottom ported S Single wiring
4 Bottom ported D Double wiring
A, B port size
Wiring type Symbol A, B port Note
S Single wiring C8 ø8 One-touch fitting Side/Bottom ported Metric size
D Double wiring N9 ø5/16" One-touch fitting Side/Bottom ported Inch size
A, B port size
Downward Upward

L8 ø8 One-touch fitting Side ported Metric size


elbow elbow

Symbol A, B port Note Symbol A, B port Note LN9 ø5/16" One-touch fitting Side ported Inch size
C2 L4 B8 ø8 One-touch fitting Side ported Metric size
Downward elbow Upward elbow

ø2 One-touch fitting ø4 One-touch fitting Side ported


Side/Bottom BN9
C3 ø3.2 One-touch fitting
ported L6 ø6 One-touch fitting Metric size ø5/16" One-touch fitting Side ported Inch size
C4 ø4 One-touch fitting Metric size LN3 ø5/32" One-touch fitting Side ported ∗Manifold block assembly accessories
C6 ø6 One-touch fitting LN7 ø1/4" One-touch fitting Inch size SY3000: SY5000 (including mixed mounting type):
N1 ø1/8" One-touch fitting Side/Bottom B4 ø4 One-touch fitting Side ported @6Tie-rod assembly for additional stations/2 @6Tie-rod assembly for additional stations/3
N3 ø5/32" One-touch fitting ported B6 ø6 One-touch fitting Metric size @2Base gasket/1 @2Base gasket/1
N7 ø1/4" One-touch fitting Inch size BN3 ø5/32" One-touch fitting Side ported @3Connector gasket/1 @3Connector gasket/1
BN7 ø1/4" One-touch fitting Inch size @4Manifold block gasket/1 @4Manifold block gasket/1
00 Plug Top ported
∗SUP/EXH end block assembly accessories
SY3000: Tension bolt/2
wSUP/EXH end block assembly @4Manifold block gasket/1
SY5000: Tension bolt/3
SY 0M 3 1 A @4Manifold block gasket/1
∗SUP/EXH block assembly accessories
eSUP/EXH block assembly SY3000: Tension bolt/None
(because the nuts are embedded)
SY5000: Tension bolt/3
SY 0M 1 A
Series Mounting
3 SY3000 SUP/EXH block assembly Direct mounting
Nil
5 SY5000 EX500/600/250/260/126, Terminal block box,
1 D0 DIN rail mounting (Without DIN rail)
Lead wire, Circular connector
11 D-sub connector P, E port size
12 Flat ribbon cable (26 pins) Symbol P, E port Note SY3000 SY5000
13 Flat ribbon cable (20 pins) C8 ø8 One-touch fitting Side/Bottom/Top ported
14 Flat ribbon cable (10 pins) C10 ø10 One-touch fitting Metric size
15 PC wiring (20 pins) N9 ø5/16" One-touch fitting Side/Bottom/Top ported
16 EX120 N11 ø3/8" One-touch fitting Inch size
Pilot/Piping type L8 ø8 One-touch fitting Side ported
Downward Upward
elbow

L10 ø10 One-touch fitting Metric size


Symbol Specifications Note
LN9 ø5/16" One-touch fitting Side ported
Nil Internal pilot
LN11 ø3/8" One-touch fitting Inch size
S Internal pilot, Built-in silencer Side ported
B8 ø8 One-touch fitting Side ported
R External pilot
elbow

B10 ø10 One-touch fitting Metric size


V Internal pilot
BN9 ø5/16" One-touch fitting Side ported
RV External pilot Top ported
BN11 ø3/8" One-touch fitting Inch size
VP Internal pilot, for silencer (supply side)∗
00 Note 1) Plug P/E port entry on one side
B Internal pilot
00U Note 2) Plug or Top ported
BS Internal pilot, Built-in silencer Bottom ported
BR External pilot Note 1) It can be selected only if no symbol or “S” or “V” or “B” is selected
∗“VP” type is plugged with an E port. for the pilot port and the piping.
Connector entry direction (for D-sub connector, Flat ribbon cable, PC wiring only) Note 2) “00U” is available only for the D-sub connector type and it has
an inch size locking bracket.
1 Upward
2 Lateral
137
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Manifold Parts No.

Replacement
쐽 Cover assembly/Silencer cover assembly/Port block assembly for SUP/EXH (end) block assembly

Parts
Mounting screw (M3)

Metal Base
Cover assembly
(Internal pilot) SY 3 0M 4 1A

Plug-in
Dent for
positioning

Silencer cover assembly


SY 3 0M 5 1A

Flat Ribbon Cable


D-sub Connector
(Internal pilot, Built-in silencer)

PC Wiring
EX510
Port block assembly
(Side/Bottom ported, External pilot) SY 3 0M 6 1AR 00
X, PE port one-touch fitting type
Nil Metric size (ø4)

Terminal D-sub Connector Plug-in Connector


Connecting Base
U Inch size (ø5/32")

Port block assembly


(Top ported, Internal pilot, for silencer SY 3 0M 6 3AV C8
(supply side))

Flat Ribbon Cable


Block Box PC Wiring
Port block assembly SY 3 0M 6 1A V C8
(Top ported, Internal/External pilot) Series Pilot type
3 SY3000 Nil Internal pilot
5 SY5000 R External pilot

Lead Wire
∗ Cover assembly, silencer cover assembly and P, E port size
port block assembly are included in the Symbol P, E port SY3000 SY5000
SUP/EXH (end) block assembly, but they need C8 ø8 One-touch fitting
to be ordered for piping direction change. C10 ø10 One-touch fitting

Connector
Circular
N9 ø5/16" One-touch fitting
Tightening torque for mounting screw (M3): 0.8 N·m
N11 ø3/8" One-touch fitting

EX120 EX126 EX260 EX250 EX600 EX500


Type 10, 11, 12: How to Increase Connector Type Manifold
1 Loosen the U-side tension bolt a , and remove
the SUP/EXH end block assembly w.

2 Screw in tie-rods for additional stations @6 to


the manifold's tie-rod @5.
Screw them in until there is no gap
between the tie-rods.

Gasket∗
3 Connect the manifold block assembly q and
SUP/EXH end block assembly w to be added,
and tighten the tension bolt a .
@6 Tie-rod
and Plug Assembly/
One-touch Fittings

for additional stations


Tightening torque for tension bolt a (M3): 0.8 N·m
Part No.

(Refer to page 134 for q, w, @5 and a .)


Manifold
Options

Caution Connecting board


1. Be sure to shut off the power and air supplies before disassembly.
Furthermore, since air may remain inside the actuator, piping
and manifold, confirm that the air is completely exhausted
Specific Product

before performing any work. ∗Gaskets (in three places) are mounted.
Precautions

2. When disassembly and assembly are performed, air leakage


may result if the tightening of the tension bolt is inadequate.

138
Series SY3000/5000

One-touch Fittings and Plug Assembly/Part No.


Refer to Changing One-touch Fittings on page 157 for replacement method.

쐽 One-touch fittings
Port size SY3000 SY5000
ø2 One-touch fitting (Straight type) VVQ1000-50A-C2 —
ø3.2 One-touch fitting (Straight type) VVQ1000-50A-C3 —
ø4 One-touch fitting (Straight type) VVQ1000-50A-C4 VVQ1000-51A-C4
ø6 One-touch fitting (Straight type) VVQ1000-50A-C6 VVQ1000-51A-C6
Metric size

ø8 One-touch fitting (Straight type) — VVQ1000-51A-C8


ø4 One-touch fitting (Elbow type) SZ3000-73-1A-L4 SZ3000-74-1A-L4
ø6 One-touch fitting (Elbow type) SZ3000-73-1A-L6 SZ3000-74-1A-L6
ø8 One-touch fitting (Elbow type) — SZ3000-74-1A-L8
ø4 One-touch fitting (Long elbow type) SZ3000-73-2A-L4 SZ3000-74-2A-L4
A, B port

ø6 One-touch fitting (Long elbow type) SZ3000-73-2A-L6 SZ3000-74-2A-L6


ø8 One-touch fitting (Long elbow type) — SZ3000-74-2A-L8
ø1/8" One-touch fitting (Straight type) VVQ1000-50A-N1 —
ø5/32" One-touch fitting (Straight type) VVQ1000-50A-N3 VVQ1000-51A-N3
ø1/4" One-touch fitting (Straight type) VVQ1000-50A-N7 VVQ1000-51A-N7
ø5/16" One-touch fitting (Straight type) — VVQ1000-51A-N9
Inch size

ø5/32" One-touch fitting (Elbow type) KJL03-95-X224 —


ø1/4" One-touch fitting (Elbow type) KJL07-95-X224 KQ2L07-14-X224
ø5/16" One-touch fitting (Elbow type) — KQ2L09-14-X224
ø5/32" One-touch fitting (Long elbow type) KJL03-95-X225 —
ø1/4" One-touch fitting (Long elbow type) KJL07-95-X225 KQ2L07-14-X225
ø5/16" One-touch fitting (Long elbow type) — KQ2L09-14-X225
ø8 One-touch fitting (Straight type) VVQ1000-51A-C8 —
Metric size

ø10 One-touch fitting (Straight type) — VVQ2000-51A-C10


ø8 One-touch fitting (Elbow type) SZ3000-74-1A-L8 —
ø10 One-touch fitting (Elbow type) — SZ3000-83-1A-L10
ø8 One-touch fitting (Long elbow type) SZ3000-74-2A-L8 —
P, E port

ø10 One-touch fitting (Long elbow type) — SZ3000-83-2A-L10


ø5/16" One-touch fitting (Straight type) VVQ1000-51A-N9 —
ø3/8" One-touch fitting (Straight type) — VVQ2000-51A-N11
Inch size

ø5/16" One-touch fitting (Elbow type) KQ2L09-14-X224 —


ø3/8" One-touch fitting (Elbow type) — KQ2L11-14-X224
ø5/16" One-touch fitting (Long elbow type) KQ2L09-14-X225 —
ø3/8" One-touch fitting (Long elbow type) — KQ2L11-14-X225

쐽 Plug assembly
SY3000 SY5000
A, B port VVQ0000-58A VVQ1000-58A
P, E port VVQ1000-58A VVQ2000-58A

139
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Manifold Options

Replacement
쐽DIN rail dimensions/weight for the SY3000 plug-in metal base and the SY3000/5000 plug-in

Parts
connector connecting base

Metal Base
VZ1000-11-1-쏔

Plug-in
∗ Refer to the DIN rail dimensions table below and specify the number in the box 첸.

L
8 (7.5)

Flat Ribbon Cable


D-sub Connector

PC Wiring
5.5

(35)
(25)

EX510
Rail mounting hole pitch 12.5

Terminal D-sub Connector Plug-in Connector


Connecting Base
No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight (g) 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37

Flat Ribbon Cable


L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5

Block Box PC Wiring


Weight (g) 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight (g) 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71

Lead Wire
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight (g) 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4

Connector
Circular
EX120 EX126 EX260 EX250 EX600 EX500
쐽DIN rail dimensions/weight for the SY5000 plug-in metal base
VZ1000-11-4-쏔
∗ Refer to the DIN rail dimensions table below and specify the number in the box 첸.

L
8
5.5

(35)
(25)

Rail mounting hole pitch 12.5 (10)

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 233.5 248 260.5 273 285.5 298 310.5 323
Weight (g) 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight (g) 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
and Plug Assembly/
One-touch Fittings

No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Part No.

Weight (g) 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
Manifold
Options

L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight (g) 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3
Specific Product
Precautions

140
Series SY3000/5000
Caution
Tightening torque for mounting screw
M2: 0.16 N·m
Manifold Options Refer to pages 149 and 151 for dimensions. M3: 0.8 N·m

쐽Blanking plate assembly How to Order Blanking Plate Assembly


(With two mounting screws)
Used when valve additions are expected or for maintenance. A SY 3 0M 26 1 A
structure is in place on the blanking plate to prevent the mounting
screws from sliding. Series Option for mounting
Mounting Mounting 3 SY3000 With mounting screw
screw screw Nil (Round head combination screw)
5 SY5000
(A) (B)
4 2 With mounting screw
B (Hexagon socket head cap screw)
Base type
1 For plug-in connector connecting base
5 1 3 2 For plug-in metal base
(EA)(P)(EB)
Circuit diagram
SY30M-26-첸A (-B) SY50M-26-첸A (-B)

쐽Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
(With a connector gasket, a base gasket, and two mounting screws) One-touch fitting
When the same manifold is used for different pressures, an individual Straight type SY 3 0M 38 1 A C6
SUP spacer assembly is used as a supply port for different pressures.
Note) When selecting an elbow type for one-touch fitting for a spacer One-touch fitting
assembly, use it faced upward, since it interferes with A and B Elbow type SY 3 0M 38 2 A L6
port piping in Type 50 and Type 10 manifolds.
Series
4 (A) 3 SY3000
2-position single valve
2 (B) 5 SY5000
Individual SUP spacer
assembly Spacer type
1 (P')
Mounting 38 Individual SUP spacer
screw 5 (EA)
1 (P) 39 Individual EXH spacer
3 (EB)
Circuit diagram Individual SUP/EXH spacer
(Mounting example of a assembly
2-position single valve)
2 Short elbow type
Part numbers of mounting
screw (2 pcs. of each) 3 Long elbow type
Base gasket SY3000: SY3000-23-12A Note) Select the long elbow type for a
SY5000: SY5000-221-12A 3-position valve when using Type
11 and Type 12 downwards.
However, Type 11 of the SY3000
series for the mixed mounting of
connector connecting bases
cannot be used downwards.
Connector gasket

쐽Individual EXH spacer assembly


Port size (Metric)
(With a connector gasket, a base gasket, and two mounting screws)
Symbol P, E port SY3000 SY5000
When valve exhaust affects other stations due to the circuit configuration, L4 ø4 One-touch fitting 쎲 쎲
this spacer assembly is used for individual valve exhaust. L6 ø6 One-touch fitting 쎲 쎲
Note) When selecting an elbow type for one-touch fitting for a spacer L8 ø8 One-touch fitting — 쎲
assembly, use it faced upward, since it interferes with A and B
port piping in Type 50 and Type 10 manifolds. Port size (Inch)
Symbol P, E port SY3000 SY5000
2-position single valve 4 (A)
2 (B)
LN3 ø5/32" One-touch fitting 쎲 —
Individual EXH spacer LN7 ø1/4" One-touch fitting 쎲 쎲
assembly LN9 ø5/16" One-touch fitting — 쎲
3/5 (E')
Mounting
screw 5 (EA)
1 (P)
3 (EB)
Port size (Metric)
Circuit diagram Symbol P, E port SY3000 SY5000
(Mounting example of a C2 ø2 One-touch fitting 쎲 —
2-position single valve)
C3 ø3 One-touch fitting 쎲 —
Part numbers of mounting
screw (2 pcs. of each)
C4 ø4 One-touch fitting 쎲 쎲
Base gasket SY3000: SY3000-23-12A C6 ø6 One-touch fitting 쎲 쎲
SY5000: SY5000-221-12A C8 ø8 One-touch fitting — 쎲
Port size (Inch)
Symbol P, E port SY3000 SY5000
N1 ø1/8" One-touch fitting 쎲 —
N3 ø5/32" One-touch fitting 쎲 쎲
Connector gasket N7 ø1/4" One-touch fitting 쎲 쎲
N9 ø5/16" One-touch fitting — 쎲
141
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Caution
Tightening torque for mounting screw
M2: 0.16 N·m
Manifold Options Refer to pages 149 and 152 for dimensions. M3: 0.8 N·m

Replacement
쐽 SUP stop valve spacer assembly with residual

Parts
pressure release valve
(With a connector gasket, a base gasket and two mounting
screws.)

Metal Base
It is used to shut off the supply air to valves individually.

Plug-in
Series Part no. 2-position single valve 4(A)
SY3000 SY30M-50-1A 2(B)
SUP stop valve spacer assembly
SY5000 SY50M-50-1A

Flat Ribbon Cable


D-sub Connector
5(EA)

PC Wiring
1(P)
3(EB)
Connector gasket
Base gasket

EX510
Circuit diagram
(Mounting example of a Mounting screw
2-position single valve)

Part numbers of mounting

Terminal D-sub Connector Plug-in Connector


screw (2 pcs. of each)

Connecting Base
SY3000: SY30M-56-1A
SY5000: SY50M-56-1A

[How to mount SUP stop valve spacer assembly with residual Valve mounting screw

Flat Ribbon Cable


pressure release valve] Tightening torque:
Series SY3000: 0.16 N·m
Insert the SUP stop valve mounting screw from the side of the spacer assembly,

Block Box PC Wiring


Series SY5000: 0.8 N·m
and mount it to the manifold. For Hexagon socket head cap screws
Tighten the SUP stop valve mounting screw to the specified tightening torque. Nominal wrench size:
Mount the valve and tighten the valve mounting screws to the specified Series SY3000: 1.5
tightening torque after mounting the SUP stop valve spacer assembly with Series SY5000: 2.5 Valve
residual pressure exhaust valve.
SUP stop valve spacer

Lead Wire
Note 1) Install the plate type nut to the spacer assembly as shown in the figure if assembly with residual pressure
it comes off. The SUP stop valve mounting screws can be tightened with
a hexagon wrench without removing the plate type nut. Plate type nut Hexagon wrench
Note 2) When the elbows are facing upwards in A and B ports in Type 10 Nominal wrench size:

Connector
manifolds, they will interfere with the piping for the spacer assembly. Series SY3000: 1.3

Circular
SUP stop valve mounting screw
Therefore, please combine the A and B ports with straight types or Series SY5000: 2
Tightening torque:
elbows facing downwards. Series SY3000: 0.16 N·m
Series SY5000: 0.8 N·m

EX120 EX126 EX260 EX250 EX600 EX500


왎Double check spacer assembly with residual pressure release <Example>
valve (Side/Bottom ported) Double check spacer assembly with residual pressure release valve
(With a connector gasket, a base gasket, and two mounting screws) 3-position exhaust center valve
It is used to hold the intermediate position of the cylinder for a long period of
time. Use a 3-position exhaust center valve when the double check spacer
assembly with residual exhaust valve is used. Double check spacer assembly
It can also be used for drop prevention at the cylinder stroke end when supply
residual pressure is released by using a 2-position single/double valve.
Note) When the elbows are facing upwards in A and B ports in Type 10 manifolds,
they will interfere with the piping for the spacer assembly. Therefore, please
combine the A and B ports with straight types or elbows facing downwards. 4 (A) 2 (B) 5 (EA)
Series Part no. 1 (P)
3 (EB)
SY3000 SY30M-60-1A Circuit diagram
SY5000 SY50M-60-1A (Intermediate stop: When 3-position exhaust center valve is mounted)

Mounting screw Intermediate stop Drop prevention


Double check spacer assembly with residual pressure release valve
Applicable valve SY35 4001 SY35 12 0 01
2-position single valve
Caution
• Air leakage from the pipe between the valve and Double check spacer assembly
cylinder or from the fittings will prevent the cylinder
from stopping for a long period of time. Check the
and Plug Assembly/
One-touch Fittings

leakage using neutral household detergent, such as


dish washing soap. Also, check the cylinder’s tube
Part No.

Base gasket gasket, piston packing and rod packing for air
leakage. 4 (A) 2 (B) 5 (EA)
Manifold

• Combining with 3-position closed center or pressure


Options

1 (P)
center valve will not work. 3 (EB)
Circuit diagram
• If the exhaust of the double check spacer is restricted
(Drop prevention: When 2-position single valve is mounted)
too much, the cylinder may not operate properly and
may not stop intermediately.
Specific Product

Connector gasket
• Set the cylinder load so that the cylinder pressure will
Precautions

Mounting screw (2 pcs. of each) be within two times that of the supply pressure.
SY3000: SY3000-23-27A
SY5000: SY5000-221-4A
142
Series SY3000/5000
Caution
Tightening torque for mounting screw
M2: 0.16 N·m
Manifold Options Refer to pages 150 and 152 for dimensions. M3: 0.8 N·m

왎Interface regulator
(With a connector gasket, a base gasket, and two mounting screws)
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure).

How to Order

SY 3 0M 05 P
Series Applicable valve Note 3)
3 SY3000 Nil For single, double, and 4-position
3 For 3-position
Pressure gauge option Note 1) Note 1) In the case of the SY3000 series with a pressure gauge, when mounting on the manifold, use
M1 No pressure gauge caution that the part numbers are different between the odd no. stations and the even no.
05 Pressure gauge with MPa display (For odd number station) stations to prevent the pressure gauges from interfering with each other.
06 Pressure gauge with MPa display (For even number station) If using a connector connecting base M10/11/12 (mixed mounting type), you can use only the
model without a pressure gauge (M1).
N5 Pressure gauge with psi display (For odd number station) Note 2)
Note 2) As per the new Measurement Law, gauges with a psi display will only be sold to overseas
N6 Pressure gauge with psi display (For even number station) Note 2) customers.
Note 3) In the case of the SY3000 series, use caution that the part numbers will differ depending on
the one for single/double and 4- and 3-position due to the different length of solenoid valves.
SY 5 0M 00 P Also, if you have selected a model with a pressure gauge, and if at least the one for 3 position
is included in the same manifold, use all the ones for 3-position to prevent the pressure
gauges from interfering with each other.
Series
5 SY5000
Regulating port
Pressure gauge option P 1(P) port
M1 No pressure gauge Part numbers of mounting screw (2 pcs. of each)
A1 4(A) port (P controlled type, A port regulation) SY3000: SY3000-23-12A
00 Pressure gauge with MPa display B1 2(B) port (P controlled type, B port regulation) SY5000: SY5000-221-6A
N0 Pressure gauge with psi display Note 2)

Mounting screw

Base gasket

Connector gasket

SY30M-05/N5-첸 SY30M-06/N6-첸 SY30M-M1-첸 SY50M-00/N0-첸 SY50M-M1-첸


(With pressure gauge/For odd number station) (Without pressure gauge/For even number station) (Without pressure gauge) (With pressure gauge) (Without pressure gauge)
Specifications

Interface regulator model SY30M-첸-첸-첸 SY50M-첸-첸 Note 1) Always apply pressure from 1(P) port in the base for interface regulator.
Applicable valve model Note 2) SY3첸 03 첸(R) SY5첸 03 첸(R) Note 2) 1(P) port pressure regulation is only available for 3-position closed center and
pressure center, and 4-position dual 3-port valves.
Regulating port 1(P), 4(A), 2(B)
Note 3) Gasket and mounting screws are included in the weight.
Set pressure range 0.1 to 0.7 MPa Note 4) ( ): Denotes the values of SY30M-첸-첸-3.
Maximum operating pressure 1.0 MPa
Fluid Air
Ambient and fluid temperature -10 to 50 (No freezing)
With pressure gauge 33(35) Note 4) 75
Weight [g] Note 3)
Without pressure gauge 27(29) Note 4) 69
(A) (B)
JIS symbol (A)4 2(B) 4 2
2(B) (A)4

(EA)5 3(EB)

(EA)5 3(EB) (EA)5 3(EB)

1
1(P) port regulation (P) 4(A) port regulation 1 2(B) port regulation 1
(P controlled type, A port regulation) (P) (P controlled type, B port regulation) (P)
143
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Caution
Tightening torque for mounting screw
M2: 0.16 N·m
Mounting Screw Part No. q (when adding optional lamination layers) M3: 0.8 N·m

Replacement
Parts
q SY3000 (M2) w SY5000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

Metal Base
SY3000-23-24A SY3000-222-1A SY5000-221-1A SY5000-222-1A

Plug-in
A Valve [for 10 valves [for 10 valves [for 10 valves [for 10 valves
<Round head combination screw> (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)]
q:SY3000-23-24A
w:SY5000-221-1A

Flat Ribbon Cable


SUP stop valve

D-sub Connector
A <Hexagon socket head cap screw>
spacer assembly

PC Wiring
q:SY3000-222-1A B with residual
B w:SY5000-222-1A pressure

EX510
release valve SY30M-56-2A SY50M-56-2A
q:SY30M-56-2A
(2 pcs.) (2 pcs.)
C w:SY50M-56-2A
Individual
C SUP (EXH) spacer

Terminal D-sub Connector Plug-in Connector


assembly

Connecting Base
A Valve

Flat Ribbon Cable


<Round head combination screw>
q:SY3000-23-33A

Block Box PC Wiring


A w:SY5000-221-5A Double check spacer
B
assembly with SY3000-23-33A SY5000-221-5A
residual pressure (2 pcs.) (2 pcs.)
B release valve

Lead Wire
Individual
C SUP (EXH) spacer
assembly

Connector
Circular
A Valve

EX120 EX126 EX260 EX250 EX600 EX500


<Round head combination screw>
q:SY3000-23-32A
A w:SY5000-221-3A Individual
B SUP (EXH) spacer
SY3000-23-32A SY5000-221-3A
B (2 pcs.) (2 pcs.)
assembly

C
Individual
C EXH (SUP) spacer
assembly

SY3000-23-24A SY3000-222-1A SY5000-221-1A SY5000-222-1A


A Valve [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)]
<Round head combination screw>
q:SY3000-23-24A
SUP stop valve
w:SY5000-221-1A spacer assembly
<Hexagon socket head cap screw> B with residual
A q:SY3000-222-1A pressure
w:SY5000-222-1A release valve
B
q:SY30M-56-4A
and Plug Assembly/
One-touch Fittings

w:SY50M-56-4A Individual
C C SUP (EXH) spacer
SY30M-56-4A SY50M-56-4A
Part No.

(2 pcs.) (2 pcs.)
assembly
D
Manifold
Options

Individual
D EXH (SUP) spacer
assembly
Specific Product
Precautions

∗ Mounting onto a manifold follows the order explained above.


Note) The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when
laminated.
144
Series SY3000/5000
Caution
Tightening torque for mounting screw
M2: 0.16 N·m
Mounting Screw Part No. w (when adding optional lamination layers) M3: 0.8 N·m

q SY3000 (M2) w SY5000 (M3)


Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

SY3000-23-24A SY3000-222-1A SY5000-221-1A SY5000-222-1A


A Valve [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)]
<Round head combination screw>
q:SY3000-23-24A
w:SY5000-221-1A SUP stop valve
A spacer assembly
<Hexagon socket head cap screw>
B with residual
q:SY3000-222-1A pressure
B w:SY5000-222-1A release valve SY30M-56-3A SY50M-56-3A
q:SY30M-56-3A (2 pcs.) (2 pcs.)
C Double check spacer
w:SY50M-56-3A
assembly with
C
residual pressure
release valve

SY3000-23-24A SY3000-222-1A SY5000-221-1A SY5000-222-1A


A Valve [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)]
<Round head combination screw>
q:SY3000-23-24A SUP stop valve
w:SY5000-221-1A spacer assembly
<Hexagon socket head cap screw> B with residual
A q:SY3000-222-1A pressure
w:SY5000-222-1A release valve
B
q:SY30M-56-5A Double check spacer
w:SY50M-56-5A assembly with SY30M-56-5A SY50M-56-5A
C C
residual pressure (2 pcs.) (2 pcs.)
release valve
D

Individual
D EXH (SUP) spacer
assembly

A Valve
<Round head combination screw>
q:SY3000-23-32A
A w:SY5000-221-7A
Interface
B regulator
SY3000-23-32A SY5000-221-7A
B (2 pcs.) (2 pcs.)
assembly

C
Individual
C SUP (EXH) spacer
assembly

∗ Mounting onto a manifold follows the order explained above.


Note) The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when
laminated.

145
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Caution
Tightening torque for mounting screw
M2: 0.16 N·m
Manifold Options ∗Refer to pages 150 and 152 for dimensions. M3: 0.8 N·m

Replacement
Parts
Mounting screw
왎Individual SUP block assembly How to Order Individual SUP/EXH Block Assembly
Used as supply port for different pressures One-touch fitting
SY 3 0M 78 1 A C6

Metal Base
when using different pressures for plug-in Straight type
connector connecting base. (Use for 1

Plug-in
One-touch fitting
station)
Used by disconnecting both sides of the
Elbow type SY 3 0M 78 2 A L6
number of stations used to supply Series

Flat Ribbon Cable


D-sub Connector
pressure from the individual SUP block 3 SY3000
(as shown in example).
Block type

PC Wiring
5 SY5000
78 Individual SUP block
∗ Specify the mounting position of the
block as well as the position where 79 Individual EXH block

EX510
the SUP passage is to be blocked on SUP blocking disk assembly
Individual SUP/EXH block assembly
the manifold specification sheet. SUP. blocking disk SUP. blocking disk
2 Short elbow type (Type 12)
Blocking is required for 1 or 2 D side Valve Individual SUP. Valve Valve U side
block 3 Long elbow type (Type 11)
positions for 1 set.

Terminal D-sub Connector Plug-in Connector


EA

Connecting Base
(2 SUP blocking disks to block SUP is EB
Note) Long elbow type is for the
SY5000 only.
attached to individual SUP block.)
∗ Electrical wiring is connected to a Port size (Metric)
number of stations in the individual Symbol P, E port SY3000 SY5000
SUP block manifold. L4 ø4 One-touch fitting

Flat Ribbon Cable


L6 ø6 One-touch fitting

Block Box PC Wiring


L8 ø8 One-touch fitting
왎Individual EXH block assembly Mounting screw
On the circuit of the plug-in connector Port size (Inch)
connection base, used to individually Symbol P, E port SY3000 SY5000
exhaust the value when the exhaust LN3 ø5/32" One-touch fitting
from the valve will affect a number of LN7 ø1/4" One-touch fitting
LN9 ø5/16" One-touch fitting

Lead Wire
stations. (Use for 1 station.)
Used by blocking both sides of the
number of stations when exhausting Port size (Metric)
individually (as shown in example). Symbol P, E port SY3000 SY5000

Connector
∗ Specify the mounting position of the C2 ø2 One-touch fitting

Circular
block as well as the position where C3 ø3.2 One-touch fitting
the EXH passage is to be blocked on EXH blocking disk assembly C4 ø4 One-touch fitting
C6 ø6 One-touch fitting

EX120 EX126 EX260 EX250 EX600 EX500


the manifold specification sheet. EXH. blocking disk EXH. blocking disk
Blocking is required for 1 or 2 D side Valve Individual EXH. Valve Valve C8 ø8 One-touch fitting
block U side
positions for 1 set. EA
Port size (Inch)
(2 sets of EXH blocking disks (4 pcs.) EB
Symbol P, E port SY3000 SY5000
to block EXH is attached to individual N1 ø1/8" One-touch fitting
EXH block.) N3 ø5/32" One-touch fitting
∗ Electrical wiring is connected to a N7 ø1/4" One-touch fitting
number of stations in the individual N9 ø5/16" One-touch fitting
EXH block manifold.

왎SUP/EXH blocking disk assembly (for connector type manifold, Type 10, 11, 12)
[SUP blocking disk]
By inserting the SUP blocking disk in the pressure supply passage of the
manifold valve, can provide two different high and low pressure in one
manifold.
[EXH blocking disk]
By inserting the EXH blocking disk in the exhaust passage of the manifold SUP blocking EXH blocking
Series
valve, can separate the exhaust from the valve so it does not affect the other disk assembly disk assembly
valves. It can also be used for the manifold for the positive pressure and SY3000 SY30M-40-1A SY30M-40-2A
vacuum mixed manifold. (2 pcs. are required to block both sides of the EXH.) SY5000 SV2000-59-2A SV2000-59-2A

왎Label for blocking disk


and Plug Assembly/

∗ If the blocking disk assembly is ordered using


One-touch Fittings

Label to indicate and confirm on the manifold where the SUP/EXH the manifold specification sheet and ordered
at the same time as the manifold, the position
Part No.

blocking disk assemblies were inserted. (3 sheets each)


where the blocking disk assembly is inserted
SUP/EXH blocking SUP blocking EXH blocking
will be labeled and shipped out.
disk label disk label disk label
Manifold
Options
Specific Product
Precautions

Series Part no.


SY3000
SJ3000-155-1A
SY5000
146
Series SY3000/5000

Manifold Options
왎Back pressure check valve assembly (Retrofit or pre-installed type)
It prevents cylinder malfunction caused by other valve exhaust entry. Insert
it into EA/EB port (valve mounting side) on the manifold side of a valve
which is affected. It is effective when a single-acting cylinder is used.
∗ When ordering assemblies incorporated with a manifold, refer to the Ordering Example below EA port
(when installed in all stations.) EB port
Note) When a check valve for back pressure prevention is desired and is to be Back pressure check valve assembly
installed only in certain manifold stations, clearly indicate the part number 2 pcs. in 1 set
and specify the mounting position on the manifold specification sheet.
<Precautions>
1. The back pressure check valve assembly is assembly parts with a check
valve structure. However, since the valve has slight air leakage, take
precautions for the exhaust air not to be restricted at the exhaust port.
2. When the back pressure check valve assembly is mounted, please contact
SMC for valve flow-rate characteristics.

Ordering Example
SS5Y3-10F1-05B-C6·····1 set (Type 10 5-station manifold base part no.)
∗SY3201-5U1·················· 5 sets (2-position double part no.)
∗SY30M-24-1A················5 sets (Back pressure check valve assembly part no.) Series Part no.
SY3000 SY30M-24-1A
∗The asterisk denotes the symbol for assembly. SY5000 SY50M-24-1A

왎Dual flow fitting (for connector connecting base, Type 10, side ported)
This is a fitting for cylinder ports which enables simultaneous actuation and increase in flow rate of valves for 2 stations.
∗ When ordering assemblies incorporated into a manifold, refer to the Ordering Example below and specify on the manifold specifications sheet.

How to Order Dual Flow Fitting

SY 3 0M 120 1A C8
Series A, B port size
3 SY3000 Symbol A, B port SY3000 SY5000
5 SY5000 C8 Metric ø8 One-touch fitting
C8: ø8 One-touch fitting
C10 size ø10 One-touch fitting N9: ø5/16" One-touch fitting
N9 Inch ø5/16" One-touch fitting
N11 size ø3/8" One-touch fitting
Ordering Example
SS5Y3-10F1-08B-CM
∗SY3100-5U1
∗SY30M-120-1A-C8
∗The asterisk denotes the symbol for assembly. Note 1) Specifically for side porting for a connector
connecting base. Cannot be attached to bottom
SY3000 SY5000 or top ported, or mixed mounting types that are
(22.8) 24.1
metal or connector connecting bases.
Note 2) When adding or changing clips, please push
them into the very end of the manifold for each
station. Also, please make sure to use the clip
13.6
11.1

that was packed together, as the clip and the


32.1
26.3

fitting for one station differ among products that


can be used with the SY5000.

왎Silencer C
(One-touch fitting connection type) B Effective area A
Series Model B C
This silencer can be mounted to the 3/5 For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
AN200-KM10 26 mm2 ø22 53.8 80.8
A

(E: EXH) port of the manifold in one step. For SY5000 (ø10)
AN300-KM10 30 mm2 ø25 70 97

왎Plug (White) Dimensions


These are inserted in unused cylinder Applicable fitting size Applicable fitting size
Model A L D Model A L D
ports and P, E ports. ød (Metric size) ød (Inch size)
2 KJP-02 8.2 17 3 1/8" KQ2P-01 16 31.5 5
ød

3.2 KQ2P-23 5 31.5 16 5/32" KQ2P-03 16 32 6


øD

4 KQ2P-04 16 32 6 1/4" KQ2P-07 18 35 8.5


6 KQ2P-06 18 35 8 5/16" KQ2P-09 20.5 39 10
A 8 KQ2P-08 20.5 39 10 3/8" KQ2P-11 22 43 11.5
L 10 KQ2P-10 22 43 12
147
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve.

Replacement
왎Name plate (for manifold) <Series SY3000>

Parts
SY3000: For SS5Y3-10 (Side ported) n=1 to 3 n=4 to 24
SY5000: For SS5Y5-10/11 (Side/Bottom ported)

Metal Base
Name plate bracket assembly and name plate mounting instructions

42.3
Insert it into the groove on the name plate bracket onto which a

Plug-in
SUP/EXH (end) block is mounted, as shown in Fig. 2. 3 1 2 3 4 5 n: Number
∗ When ordering assemblies incorporated with a manifold, refer to the Pitch of stations
Ordering Example below. 10.5

Flat Ribbon Cable


D-sub Connector
SS5Y3-10

PC Wiring
SS5Y5- 10
11
Confirm that the mounting direction is correct.

EX510
Mounting and Option Tightening torque for mounting screw (M3): 0.8 N·m
Symbol Mounting option SY30M-86-첸(N)
Mounting screw Name plate
AA Name plate (printed), (directly mounting) Name plate bracket
(M3) 첸 is the number of stations (1 to 24).

Terminal D-sub Connector Plug-in Connector


A Name plate (printed), DIN rail mounted (With DIN rail)

Connecting Base
SY30M-85-1A
A0 Name plate (printed), DIN rail mounted (Without DIN rail)
Name plate bracket assembly
A3 Name plate (printed), DIN rail specified length (For 3 stations)
(Supplied individually)
Please align this line along
A24 Name plate (printed), DIN rail specified length (For 24 stations) Name plate insertion hole the end of the 2 position valve.
BA Name plate (no printing), (direct mounting)

Flat Ribbon Cable


Port block
B Name plate (no printing), DIN rail mounted (With DIN rail)
Valve end

Block Box PC Wiring


B0 Name plate (no printing), DIN rail mounted (Without DIN rail) SUP/EXH end block
B3 Name plate (no printing), DIN rail specified length (For 3 stations) (External pilot type)

B24 Name plate (no printing), DIN rail specified length (For 24 stations)
Note) You cannot mount name plates onto Type 12 (top ported) and Type
10 (side ported) mixed mounting types with top ported valves, nor

Lead Wire
onto manifolds with optional laminated spacers. Also, no name
plate settings are available for the SY3000/SY5000 mixed mounting
types. SUP/EXH
block

Connector
Ordering Example Figure 1 Figure 2

Circular
Insertion hole
SS5Y3-10F1-05UR-C6AA 1 set
∗SY3200R-5U1 5 sets

EX120 EX126 EX260 EX250 EX600 EX500


<Series SY5000>
∗ The asterisk denotes the symbol for assembly.
n=1 to 3 n=4 to 24

왎If adding a name plate


62.5

If adding a name plate to a manifold in use, you must order a name


plate bracket assembly, in addition to ordering a name plate. 1 3 1 2 3 4 5 n: Number
Refer to the table below for the part number. and the amount. Pitch of stations
P=16
Name plate part no.
Series SS5Y3-10 SS5Y5-10/11 Note Make sure to mount
Name Printed SY30M-86-첸N SY50M-86-첸N 첸:Number of stations in the right direction. (20°)
plate No printing SY30M-86-첸 SY50M-86-첸 (1 to 24)
Tightening torque for mounting screw (M3): 0.8 N·m SY50M-86-첸(N)
Name plate bracket assembly part no. and number of items ordered
Name plate
Series SS5Y3-10 SS5Y5-10/11 Mounting screw 첸 is the number of stations (1 to 24).
Name plate bracket
Name plate assembly part no. SY30M-85-1A SY50M-85-1A (M3)
Internal pilot
2 pcs.
U/D piping
Manifold SUP/EXH Internal pilot
2 pcs.
block assembly double sided piping SY50M-85-1A Please align this
2 pcs.
Pilot type External pilot Name plate bracket assembly line along the end of
1 pc. Note)
and P, E port entry U/D piping (Supplied individually) the 2 position valve.
External pilot Valve end
and Plug Assembly/

Not required Note)


One-touch Fittings

double sided piping SUP/EXH


end block
Note) If the manifold is an external pilot, an insertion slot for name plates
Part No.

is on the port block of the SUP/EXH block assembly. Thus, a


bracket assembly is no longer required on the port piping side.
Manifold
Options

Caution
1. Be sure to shut off the power and air supplies before mounting the
name plate bracket assembly. Furthermore, since air may remain SUP/EXH
inside the actuator, piping and manifold, confirm that the air is block
Specific Product

completely exhausted before performing any work. Figure 1 Figure 2


Precautions

2. When disassembly and assembly are performed, air leakage may


result if the tightening of the bracket mounting screws is inadequate.

148
Series SY3000/5000

Dimensions: Manifold Options/Series SY3000


쐽 Blanking plate assembly 쐽 Individual SUP/EXH spacer assembly
(Top/Bottom ported)

B A B A B A B A B A B A 3/5E

92.6

92.6
92.7
14 A 14 A 4A 4A 4A 4A
89

89
101.2

101.2
111.6

111.6
1P
12 B 12 B 2B 2B 2B 2B

3.6

14
7.2

13.9
One-touch fitting
(SUP port, EXH port)
One-touch fitting Applicable tube O.D.: ø4, ø5/32"
1 P
(SUP port, EXH port) : ø6, ø1/4"
Applicable tube O.D.: ø4, ø5/32"
62.6

63.1

: ø6, ø1/4"
2B 2 B2 B 3/5 E

4 A4 A
4A

<Type 50, 51, 52> <Type 10, 12>

C6:92.3
N7:96.1
C6:91.8
N7:95.6
1 P

LN7:63.8
L6 :61.3
LN7:63.3
L6 :60.8
2 B2 B 3/5 E

4 A4 A

<Type 51, 52> <Type 12>

쐽 Individual SUP/EXH spacer assembly 쐽 SUP stop valve spacer assembly


(Side ported) with residual pressure release valve

B A B A B A B A B A B A B A B A
92.6

92.6

14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
89

89

101.2

101.2

12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

LOCK LOCK

PUSH PUSH
(3.9)

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø2 Applicable tube O.D.: ø2
: ø3.2, ø1/8" : ø3.2, ø1/8"
: ø4, ø5/32" : ø4, ø5/32"
: ø6, ø1/4" : ø6, ø1/4"

1 P 1 P
1 P 1 P
77.6
78.1
77.6

78.1

2B 2 B2 B 3/5 E 2B 2 B2 B 3/5 E
39.5
39

4 A4 A 4 A4 A
4A 4A

<Type 50> <Type 10>


<Type 50, 51, 52> <Type 10, 12>

149
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Dimensions: Manifold Options/Series SY3000

Replacement
왎Double check spacer assembly with residual 왎Individual SUP/EXH block assembly

Parts
pressure release valve (Top ported)

Metal Base
Plug-in
B A B A B A B A B A 3/5E

92.6

92.6
14 A 14 A 14 A 14 A 4 A
89

101.2
112.8

112.8

Flat Ribbon Cable


D-sub Connector
SUP
1P
12 B 12 B 12 B 12 B 2 B

PC Wiring
EX510
LOCK LOCK

3.6
PUSH PUSH

One-touch fitting
(SUP port, EXH port)

Terminal D-sub Connector Plug-in Connector


Connecting Base
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"

1 P
83.6

1 P

LN7:72.3
L6 :69.8
84.1

Flat Ribbon Cable


Block Box PC Wiring
2B 2 B2 B 3/5 E 2 B2 B 3/5 E

4 A4 A 4 A4 A
4A

<Type 50, 51> <Type 10> <Type 12>

Lead Wire
Connector
Circular
왎Interface regulator assembly 왎Individual SUP/EXH block assembly

EX120 EX126 EX260 EX250 EX600 EX500


(Side ported)

B A B A B A B A B A B A B A B A B A
(100.7)

(100.7)

92.6
92.2

92.2
92.6
89

14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
(111.7)
103.2

103.2
(118.3)

(111.7)
109.8

109.8
(118.3)

SUP

12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

05
MAX.14

MAX.14

SY30M- N5 -첸-첸
06
SY30M- N6 -첸-첸 One-touch fitting
SY30M-M1-첸-첸 (SUP port, EXH port)
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
1 P
: ø6, ø1/4"
1 P 1 P
77.6
76.9

78.1
77.4
62.1

62.6

and Plug Assembly/


One-touch Fittings

2 B2 B 3/5 E
48

2B 2 B2 B2 B2 B 3/5 E
39.9

40.4

4 A4 A
4 A4 A4 A4 A
4A
Part No.

<Type 50, 51, 52> <Type 10, 12> <Type 10>


Manifold
Options

∗The dimensions within ( ) applies to the SY30M-첸-첸-3.


Specific Product
Precautions

150
Series SY3000/5000

Dimensions: Manifold Options/Series SY5000


쐽 Blanking plate assembly 쐽Individual SUP/EXH spacer assembly
(Top/Bottom ported)

BA BA BA BA BA BA 3/5
14 A 14 A 4A 4A 4A 4A

106.2
113.4

113.4

116.7
116.6

126.5
126.4
E
81.6

142.5
142.4
1

P
12 B 12 B 2B 2B 2B 2B

12.6

5.5

18.2
18.2
One-touch fitting One-touch fitting
73.2

1 P
68.6

2B
2 B2 B (SUP port, EXH port) (SUP port, EXH port)
3/5 E
Applicable tube O.D.: ø4 Applicable tube O.D.: ø4,
4A : ø6, ø1/4" : ø6, ø1/4"
4 A4 A
: ø8, ø5/16" : ø8, ø5/16"

<Type 50, 51, 52> <Type 10, 11, 12>

(108.8)
(104.2)

(76.8)
(72.2)
1 P
2 B2 B

3/5 E

4 A4 A

<Type 51, 52> <Type 11, 12>

쐽 Individual SUP/EXH spacer assembly 쐽 SUP stop valve spacer assembly


(Side ported) with residual pressure release valve

BA BA BA BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
106.2

106.2
113.4

113.4
127.7

127.9

12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

LOCK LOCK
(6.1)

PUSH PUSH

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4" : ø6, ø1/4"
: ø8, ø5/16" : ø8, ø5/16"
90.7
86.1

1 P
2 B2 B
2B
3/5 E
1 P
1 P 4A
90.7
86.1

4 A4 A
1 P
2 B2 B
2B
51.6
47

3/5 E <Type 50, 51, 52> <Type 10, 11, 12>


4A
4 A4 A

<Type 50> <Type 10>

151
5 Port Solenoid Valve Series SY3000/5000

Construction Specifications
Dimensions: Manifold Options/Series SY5000

Replacement
왎Double check spacer assembly with residual 왎Individual SUP/EXH block 왎Individual SUP/EXH block

Parts
pressure release valve assembly (Top ported) assembly (Side ported)

Metal Base
Plug-in
B A B A B A B A
14 A 14 A 14 A 14 A B A 3/5 B A
106.2

4 A

113.4
14 A

113.4
113.4
138.6

138.8

Flat Ribbon Cable


126.7
E

D-sub Connector
1

PC Wiring
12 B 12 B 12 B 12 B SUP SUP
P
2 B 12 B

EX510
LOCK LOCK
PUSH PUSH

5.7

Terminal D-sub Connector Plug-in Connector


Connecting Base
One-touch fitting
(SUP port, EXH port) One-touch fitting
Applicable tube O.D.: ø4 (SUP port, EXH port)
: ø6, ø1/4" Applicable tube O.D.: ø4, ø5/32"
101.2

: ø8, ø5/16" : ø6, ø1/4"


96.6

1 P : ø8, ø5/16"

Flat Ribbon Cable


2 B2 B
2B

Block Box PC Wiring


3/5 E P
4A
4 A4 A 1 1

(88.9)
1 P 1 P
<Type 50, 51> <Type 10, 11>

63.7
2 B2 B 2 B2 B

3/5 E 3/5 E

4 A4 A 4 A4 A

Lead Wire
<Type 12> <Type 10>

Connector
Circular
EX120 EX126 EX260 EX250 EX600 EX500
왎Interface regulator assembly 왎Individual SUP/EXH block assembly
(Bottom ported)

BA BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A 14 A B A
106.2

113.4

14 A
113.4
127.5

127.5
145.5

145.7

142.7

12 B 12 B 12 B 12 B 12 B 12 B SUP

12 B
21.7
MAX.21
MAX.21

00 One-touch fitting
SY50M- N0 -첸
(SUP port, EXH port)
SY50M-M1-첸 Applicable tube O.D.: ø4,
: ø6, ø1/4"
P : ø8, ø5/16"
and Plug Assembly/
One-touch Fittings

Part No.
96.2
92.4

1 P
91.6
87.8

(38.5)
74.5

79.1

2 B2 B2 B
54.6

2B
50

Manifold
Options

3/5 E
4A
4 A4 A4 A

<Type 50, 51, 52> <Type 10, 11, 12> <Type 11>
Specific Product
Precautions

152
Series SY3000/5000
Specific Product Precautions 1
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.

Valve Mounting Back Pressure Check Valve

Caution Caution
Mount it so that there is no slippage or deformation in gaskets, There are two types of back pressure check valves; the one
and tighten with the tightening torque as shown below. which is built into a valve (with rubber seal type only) and the one
which is built in on the manifold side with connector connection.
Model Thread size Tightening torque Both of them have a check valve built-in to prevent back
SY3000 M2 0.16 N·m pressure. For this reason, use caution that the valves with
SY5000 M3 0.8 N·m external pilot specification cannot be pressurized from exhaust
port [3/5(E)]. As compared with the types which do not integrate
Manual Override the back pressure check valve, C value of the flow-rate
characteristics goes down. Please contact SMC for details.
Warning
Regardless of an electric signal for the valve, the manual override Exhaust Throttle
is used for switching the main valve. Connected actuator is
started by manual operation. Use the manual override after
confirming that there is no danger. Caution
쐽Non-locking push type The SY series pilot valve and main valve share a common
Press in the direction of the arrow. exhaust inside the valve. Therefore, do not block the exhaust port
when arranging the piping.

Used as a 3-Port Valve

Caution
쐽Push-turn locking slotted type [Type D] 쐽In case of using a 5-port valve as a 3-port valve
Push down on the manual override with a small flat head The SY3000/5000 series can be used as normally closed (N.C.)
screwdriver until it stops. Turn it clockwise by 90° to lock it. or normally open (N.O.) 3-port port valves by closing one of the
Turn it counterclockwise to release it. cylinder ports 4(A) or 2(B) with a plug. However, they should be
If it is not turned, it can be operated the same way as the non- used with the exhaust ports kept open. They are convenient at
locking type. times when a double solenoid type 3-port valve is required.

Locked Plug position B port A port


position Type of actuation N.C. N.O.
Plug Plug
Number of solenoids

Single
PUSH
TURN

Plug Plug
B A
Double

Caution
Do not apply excessive torque when turning the manual override.
[0.1 N·m] Valve and Manifold Combination
When locking the manual override, be sure to push it down
before turning. Turning without first pushing it down can cause The SY series plug-in valve has the common configuration of the
3
damage to the manual override and other trouble such as air valve mounting surface between base mounted type (SY 5 쏔0쏔)
leakage, etc. and top ported type (SY 35 쏔3쏔), therefore, it can be mounted to
all manifolds of the side ported type (type 50 and type 10), the
쐽Slide locking type (Manual) OFF Locked bottom ported type (type 51 and type 11) and the top ported type
ON position (type 52 and type 12).
For example, air output can be obtained from both sides of the A
and B ports of the manifold and the valve by mounting a top
OFF ported valve to a side ported or bottom ported manifold , and a
pressure switch can be connected to the output port on one side.
B
However, when selecting valves and manifolds, note that when a
ON A base mounted valve is mounted to a top ported manifold, there
will be no output from the A and B port.

It is locked by sliding the manual override all the way in the


direction indicated by the arrow (ON side) with a small flat head
screwdriver or with your fingers. Slide it in the direction indicated
by the arrow (OFF side) to release it.
153
Series SY3000/5000

Construction Specifications
Specific Product Precautions 2
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.

Replacement
Parts
Light/Surge Voltage Suppressor

Metal Base
Caution

Plug-in
쐽Polar type 쐽With power saving circuit
Positive common Negative common Power consumption is decreased by approx. 1/3 by reducing

Flat Ribbon Cable


D-sub Connector
Single solenoid Single solenoid the wattage required to hold the valve in an energized state.

PC Wiring
(Effective energizing time is over 67 ms at 24 VDC.)
Light/surge voltage suppressor (쏔Z) Light/surge voltage suppressor (쏔NZ) Note) Be careful with the energizing time, as quick response and high pressure
types will become operational when loaded at more than 40 ms.

EX510
Polarity protection diode Polarity protection diode

COM COM <Standard>


(+) (–) (+)
Coil

Coil
LED LED

Timer circuit
Coil
[SOL.a] (Orange) [SOL.a] (Orange) LED

Diode

Terminal D-sub Connector Plug-in Connector


(–) (+)

Connecting Base
Polarity protection diode
Not available for the 12 VDC
Surge voltage suppressor (쏔S) Surge voltage suppressor (쏔NS) i1
specification. i2
(–)
Polarity protection diode Polarity protection diode
i1: Starting current, i2: Holding current
COM COM
Polarity protection diode Diode
(+) (–)

Flat Ribbon Cable


<High pressure>
Coil

Coil

[SOL.a] [SOL.a] Red (+)

Block Box PC Wiring


(–) (+)

PWM circuit
Coil
Positive common Negative common
Double solenoid, Double solenoid, LED
Black (–)
3-position, 4-position 3-position, 4-position
The above circuit reduces the current consumption when holding

Lead Wire
Light/surge voltage suppressor (쏔Z) Light/surge voltage suppressor (쏔NZ) in order to save energy. Refer to the electrical power waveform
[SOL.b] [SOL.b] as shown below.
(–) (+)
LED LED <Electrical power waveform with power saving circuit>
Coil

Coil

(Green) (Green)

Connector
COM COM

Circular
(+) (–) Applied voltage
24 V
Coil

Coil

Polarity protection diode Polarity protection diode


LED LED
[SOL.a] (Orange) [SOL.a] (Orange)

EX120 EX126 EX260 EX250 EX600 EX500


(–) (+) 0V

Surge voltage suppressor (쏔S) Surge voltage suppressor (쏔NS)


Polarity protection diode Polarity protection diode Standard
0.35 (0.9) W
[SOL.b] [SOL.b]
(–) (+) With power saving
Coil

Coil

circuit
COM COM 0.1 (0.4) W
(+) (–)
Coil

Coil

[SOL.a] [SOL.a] 0W
(–) (+) 67 ms (40 ms)

The values in ( ) are for the high pressure and quick response types.
쐽Non-polar type
• The 12 VDC specification with power saving circuit (standard
With surge voltage suppressor (쏔R) specification) does not have the polarity protection diode. Do
Single solenoid Double solenoid not make a mistake with the polarity.
[SOL.b]
• Since the voltage will drop by approx. 0.5 V due to the tran-
(–, +) sistor, pay attention to the allowable voltage fluctuation. (For
COM details, refer to the solenoid specifications of each type of
Coil

Varistor
(+, –)
COM valve.)
Coil

Varistor (+, –)
[SOL.a]
Coil

(–, +) Varistor Residual voltage of the surge voltage suppressor


and Plug Assembly/

[SOL.a]
One-touch Fittings

(–, +)
Note) If a varistor or diode surge voltage suppressor is used,
there is some residual voltage to the protection element
Part No.

With light/surge voltage suppressor (쏔U) and rated voltage. Therefore, refer to the below table and
Single solenoid Double solenoid pay attention to the surge voltage protection on the control-
Manifold

ler side. Also, since the response time does change, refer
Options

[SOL.b] to the valve specifications on page 8.


(–, +)
COM
Coil

Varistor Residual Voltage


(+, –) LED LED
(Orange) COM (Green)
Coil

Specific Product

Varistor (+, –) LED Surge voltage DC


suppressor
Precautions

[SOL.a] (Orange) 24 V 12 V
Coil

(–, +) Varistor
[SOL.a] S, Z Approx. 1 V
(–, +) R, U Approx. 47 V Approx. 32 V
154
Series SY3000/5000
Specific Product Precautions 3
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.

Continuous Duty Countermeasure for Surge Voltage Intrusion


쐽Sneak-in of surge voltage
Caution With non-polar type valves, at times of sudden interruption of
If a valve is energized continuously for a long period of time, the the loading power supply, such as emergency shutdown,
rise in temperature due to heat-up of the coil assembly may surge voltage intrusion may be generated from loading
cause a decline in solenoid valve performance, reduce service equipment with a large capacity (power consumption), and the
life, or have adverse effects on peripheral equipment. If the valve valve in a de-energized state may switch over (see Figure 1).
is energized continuously for a long period of time, be sure to use When installing a breaker circuit for the loading power supply,
a valve with power saving circuit. In particular, if three or more consider using a valve with polarity (with polarity protection
adjacent stations on the manifold are energized simultaneously diode), or install a surge absorption diode between the loading
for extended periods of time or if the valves on A side and B side equipment COM line and the output equipment COM line (see
are energized simultaneously for a long period of time, take Figure 2).
special care as the temperature rise will be greater.

Output circuit
Surge voltage
24 V
0V
sol.1: Energized
R – 60 V
Surge voltage
Internal circuit

0V
sol.2: De-energized
R – 60 V
Surge voltage
24 V
0V
Large capacity
load: Energized
R
– 60 V

Relay
Power supply
circuit breaker

24 VDC

Figure 1. Surge intrusion circuit example (NPN outlet example) (24 VDC)

Output circuit
Surge voltage
24 V
0V
sol.1: Energized –2 V or less
R

Surge voltage
Internal circuit

0V
sol.2: De-energized –2 V or less
R
Surge voltage
24 V
0V
Large capacity –2 V or less
R load: Energized

Diode Countermeasure
parts
– (Anode) + (Cathode)
Relay
Power supply
circuit breaker

24 VDC

Figure 2. Surge intrusion circuit example (NPN outlet example) (24 VDC)

155
Series SY3000/5000

Construction Specifications
Specific Product Precautions 4
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.

Replacement
Parts
Light Indication Port Block Assembly and How to Change Piping Types between Top and Side

Metal Base
Light
When equipped with
Caution

Plug-in
A side: Orange
indicator light and surge B side: Green
voltage suppressor, the light For top ported type, the port size of A and B ports can be
window turns orange when changed by switching the port block assemblies which are

Flat Ribbon Cable


solenoid a is energized, and

D-sub Connector
mounted on the body. The piping method can also be changed by
it turns green when solenoid Solenoid a switching the top ported type port block assembly with the side

PC Wiring
b is energized. ported type cover assembly. Also, it may cause air leakage if the
Solenoid b mounting screws are not tightened securely enough when they

EX510
are switched. Take care to tighten to the correct tightening torque.
Type 5쏔 (Metal Base) Changing Connector Entry Direction Refer to page 13 for part numbers of port block assembly and
body cover assembly.
Caution When switching them while valves are mounted on a manifold,

Terminal D-sub Connector Plug-in Connector


Connecting Base
remove the clip with a flat head screwdriver before switching the
Connector direction for electrical entry of D-sub connector, flat port plugs and the one-touch fittings. It may cause air leakage if
ribbon cable and PC wiring can be changed. the mounting screws are not tightened or the clip is not inserted
If the directional change is required, push the lever on both sides securely enough when they are switched. Take care to tighten to
to remove the connector and change the connector direction for the correct tightening torque.

Flat Ribbon Cable


electrical entry as shown in the figure. Since lead wire
assemblies are attached to Mounting

Block Box PC Wiring


the connector, excessive screw Caution
pulling or twisting can cause Tightening torque
broken wires or other trouble. M2: 0.16 N·m
Also, take precautions so Port block assembly M3: 0.8 N·m
that lead wires are not Thread piping

Lead Wire
caught and pinched when
installing the connector.

Mounting screw

Connector
Type 1쏔 (Connector Connecting Base) Changing Connector Entry Direction

Circular
Caution

EX120 EX126 EX260 EX250 EX600 EX500


Connector direction for electrical entry of D-sub connector, flat Port block assembly
ribbon cable and PC wiring can be changed. If the directional One-touch fitting
change is required, slide the lever on the side of the connector
block to the FREE position, and then change the direction as Body cover
shown in the figure. Also, before connecting the connector, be assembly ∗ Part number is not shown on
sure to return the lever to the LOCK position. (If the lever is the body cover assembly.
difficult to slide, move the connector a little bit to make it easier to
slide the lever.) If an excessive force
is applied on the connector in the 쐽How to change while mounted on a manifold
LOCK position, the connector block
Port block assembly
may be damaged. Also, using in
Refer to page 138.
such a way that the connector floats E
FRE
in the FREE position, it may cause
C K
O
the lead wire, etc. to break. Thus, L

refrain from using in these ways.


Exchange the one-touch
fittings with the port plugs.
Clip
Tension bolt a
Fixation of DIN Rail Mounting Type Manifold Refer to pages
134 and 138.
When the manifold is fixed with bolts on a mounting surface, etc., Plate
it can be operated just by fixing on both ends of the DIN rail if the
and Plug Assembly/
One-touch Fittings

bottom surface of the DIN rail is entirely in contact with the


mounting surface when mounted horizontally.
Part No.

However, if it is used with other mounting or with side or reverse


mounting, fix the DIN rail with bolts at regular intervals. As a
Manifold
Options

guide, insert bolts in 2 positions for 2-5 stations, 3 positions for 6-


10 stations, 4 positions for 11-15 stations, 5 positions for 16-20
stations and 6 positions for 21-24 stations.
Plug assembly
Take the same measures for horizontal mounting if the mounting
Specific Product

surface vibrates. For SY3000


Removable by screw-
Precautions

If fixed at lesser points than specified and use it, there could be a
ing an M3 screw into
warp or torsion in the DIN rail and the manifold and lead to bring Plug assembly
the center hole.
some troubles such as air leakage. Plate Refer to page 139.
156
Series SY3000/5000
Specific Product Precautions 5
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.

Changing One-touch Fittings Other Tube Brands

Caution Caution
By replacing one-touch fittings of valve or manifold base, it is 1. When using other than SMC brand tube, confirm
possible to change the connection diameter of the 4(A), 2(B), that the following specifications are satisfied with
1(P), 3/5(E) ports. respect to the tube outside diameter tolerance.
When replacing the one-touch fittings, remove the clip or the 1) Nylon tube within ±0.1 mm
plate and the plate mounting screws with a screwdriver before 2) Soft nylon tube within ±0.1 mm
pulling the one-touch fittings off. Mount the one-touch fittings by 3) Polyurethane tube within +0.15 mm
following the removal procedure in reverse. –0.2 mm
It may cause air leakage if the mounting screws are not tightened Do not use tube which do not meet these outside diameter
or the clip and the clip plate are not inserted securely enough tolerances. It may not be possible to connect them, or they
when they are switched. Take care to tighten to the correct may cause other trouble, such as air leakage or the tube
tightening torque. Refer to page 139 for part numbers of one- pulling out after connection.
touch fittings for valve or manifold.

쐽Valve One-touch Fittings


쐽Tube attachment/detachment for one-touch fittings
One-touch fitting 1) Tube attachment
1. Take a tube having no flaws on its periphery and cut it off
at a right angle. When cutting the tube, use tube cutters
TK-1, 2 or 3. Do not use pinchers, nippers or scissors,
Port plate etc. If cutting is done with tools other than tube cutters,
the tube may be cut diagonally or become flattened, etc.,
making a secure installation impossible. Allow some extra
Caution length in the tube.
2. Grasp the tube and push it in slowly, inserting it securely
Tightening torque
all the way into the fitting.
M2: 0.16 N·m 3. After inserting the tube, pull on it lightly to confirm that it
M3: 0.8 N·m will not come out. If it is not installed securely all the way
into the fitting, this can cause problems such as air
leakage or the tube pulling out.
쐽Plug-in metal base
2) Tube detachment
쐌Side ported Clip 쐌Bottom ported
1. Push in the release button sufficiently, pushing its collar
equally around the circumference.
One-touch
fitting 2. Pull out the tube while holding down the release button
so that it does not come out. If the release button is not
pressed down sufficiently, there will be increased bite on
the tube and it will become more difficult to pull it out.
Plate
3. When the removed tube is to be used again, cut off the
portion which has been chewed before reusing it. If the
Plate mounting chewed portion of the tube is used as is, this can cause
screw trouble such as air leakage or difficulty in removing the
tube.
쐽Plug-in connector connecting base
쐌Side ported 쐌Bottom ported

Port plate Secure enough space


SUP/EXH block between the manifold
Clip blocks when the plate is
One-touch detached and attached.
fitting
Plate

Manifold block
Manifold block

157
Series SY3000/5000

Construction Specifications
Specific Product Precautions 6
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.

Replacement
Parts
One-touch Fittings

Metal Base
Caution

Plug-in
When fittings are used, they may interfere with one another depending on their types and sizes. Therefore, the dimensions of the fittings
to be used should first be confirmed in their respective catalogs.

Flat Ribbon Cable


D-sub Connector
Fittings whose compliance with the SY series is already confirmed are stated below. If the fitting within the applicable range is selected,
there will not be any interference.

PC Wiring
Applicable Fittings: Series KQ2H, KQ2S

EX510
Series KJH, KJS
Port Applicable tube O.D.
Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12

Terminal D-sub Connector Plug-in Connector


Connecting Base
KQ2H
KJH
SY3쏔3 01 -쏔쏔-M5 4A, 2B M5
KQ2S
KJS
KQ2H

Flat Ribbon Cable


KJH

Block Box PC Wiring


1P, 5EA, 3EB 1/8
KQ2S
KJS
KQ2H
KJH
SY3000 X, PE M5
KQ2S

Lead Wire
SS5Y3-50/51/52(R) KJS
Manifold base KQ2H
1/8
KJH

Connector
KQ2S

Circular
KJS
4A, 2B
KQ2H

EX120 EX126 EX260 EX250 EX600 EX500


M5
KJH
KQ2S
KJS

Port Applicable tube O.D.


Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
KJH
SY5쏔3 01 -쏔쏔-01 4A, 2B 1/8
KQ2S
KJS
KQ2H
1P, 5EA, 3EB 1/4
KQ2S
KQ2H
KJH
SY5000 X, PE M5
KQ2S
SS5Y5-50/51/52(R) KJS
Manifold base
KQ2H
and Plug Assembly/
One-touch Fittings

1/4
Part No.

KQ2S
4A, 2B
KQ2H
Manifold
Options

KJH
1/8
KQ2S
KJS
Specific Product
Precautions

158
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or
moderate injury.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of ISO 10218-1: Manipulating industrial robots - Safety.
Warning: risk which, if not avoided, could result in death or
serious injury.
etc.

Danger indicates a hazard with a high level of risk


Danger : which, if not avoided, will result in death or serious
injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating
If considering using the product in other industries, consult SMC
conditions, its compatibility with specific equipment must be decided by
the person who designs the equipment or decides its specifications beforehand and exchange specifications or a contract if necessary.
based on necessary analysis and test results. The expected performance If anything is unclear, contact your nearest sales branch.
and safety assurance of the equipment will be the responsibility of the
person who has determined its compatibility with the product. This person
should also continuously review all specifications of the product referring
to its latest catalog information, with a view to giving due consideration to
Limited warranty and Disclaimer/
any possibility of equipment failure when configuring the equipment. Compliance Requirements
2. Only personnel with appropriate training should operate The product used is subject to the following “Limited warranty and
machinery and equipment.
The product specified here may become unsafe if handled incorrectly. Disclaimer” and “Compliance Requirements”.
The assembly, operation and maintenance of machines or equipment Read and accept them before using the product.
including our products must be performed by an operator who is
appropriately trained and experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and
machinery/equipment until safety is confirmed. 1. The warranty period of the product is 1 year in service or 1.5
1. The inspection and maintenance of machinery/equipment should only years after the product is delivered.∗2)
be performed after measures to prevent falling or runaway of the Also, the product may have specified durability, running distance or
driven objects have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures
as mentioned above are implemented and the power from any 2. For any failure or damage reported within the warranty period which is
appropriate source is cut, and read and understand the specific clearly our responsibility, a replacement product or necessary parts will
product precautions of all relevant products carefully. be provided.
3. Before machinery/equipment is restarted, take measures to prevent This limited warranty applies only to our product independently, and not
unexpected operation and malfunction.
to any other damage incurred due to the failure of the product.
4. Contact SMC beforehand and take special consideration of
safety measures if the product is to be used in any of the 3. Prior to using SMC products, please read and understand the warranty
following conditions. terms and disclaimers noted in the specified catalog for the particular
1. Conditions and environments outside of the given specifications, or use products.
outdoors or in a place exposed to direct sunlight.
∗2) Vacuum pads are excluded from this 1 year warranty.
2. Installation on equipment in conjunction with atomic energy, railways, A vacuum pad is a consumable part, so it is warranted for a year after it is
air navigation, space, shipping, vehicles, military, medical treatment, delivered.
combustion and recreation, or equipment in contact with food and Also, even within the warranty period, the wear of a product due to the use of
beverages, emergency stop circuits, clutch and brake circuits in press the vacuum pad or failure due to the deterioration of rubber material are not
applications, safety equipment or other applications unsuitable for the covered by the limited warranty.
standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, Compliance Requirements
or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double The exports of SMC products or technology from one country to another are governed by the relevant
interlock for possible failure by using a mechanical protective function, security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC
and periodical checks to confirm proper operation. product to another country, assure that all local rules governing that export are known and followed.

Version B ¡Added the EX260 Integrated-type (For Output) Serial Transmission System. ¡Changed the part numbers for A, B port mixed sizes for plug-in connector
¡Added EtherNet/IP™ and EtherCAT to the EX600 Integrated-type (For Input/Output) connecting bases for Type 10 (side ported), Type 11 (bottom ported),
Revisions

Serial Transmission System (Fieldbus System). Type 12 (top ported).


¡Additional Options: ¡Deleted the mixed specification for A, B port piping specification for
· Interface regulator assembly · Dual flow fitting plug-in connector connecting base for Type 12 (top ported).
· Individual SUP block assembly · Name plate for manifolds ¡Number of pages increased from 148 to 164. PY
· Individual EXH block assembly

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

Akihabara UDX 15F,


4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
© 2011 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice D-DN 1st printing NY printing PY 7850SZ Printed in Japan.
and any obligation on the part of the manufacturer. This catalog is printed on recycled paper with concern for the global environment.
Fieldbus System New ®

(Output device for driving 5 port solenoid valves)


RoHS
Compact
28 mm Space-saving Installation
(Actual size) EtherNet/IP ™ added !
¡IP67∗
∗ For units with D-sub connector,
and when connected to S0700 manifolds, it is IP40.

¡Drives up to 32 solenoids
Daisy-chain wiring
communication

Applicable Fieldbus protocols

New

Top ported valve Bottom ported valve Side ported valve 7 mm width valve
Mixed valve sizes manifold

IP67 IP67 IP67 IP40

Series EX260 CAT.NAS02-25B


Manifold length is shortened by the small Wiring and piping from the same direction is possible.
fieldbus output module (SI unit). (for side ported)
Effective for installation in locations where space is
28.2 mm limited above the valve.
81 mm

Existing model EX250

External branch connector is not necessary. Daisy-chain wiring is possible. Reduced wiring space
EX260 Branch connector
Existing model (EX250)

External terminating resistor is not necessary. Product Specification Variations


(Only available for M12 PROFIBUS DP,
CC-Link communication connectors)
ON/OFF switching is possible with an internal terminating
resistor. External terminating resistor is not necessary. 16 16 16 16 16 16
Number of
External terminating resistor outputs 32 32 32 32 32 32

PNP PNP PNP PNP PNP PNP


Output polarity
NPN NPN NPN NPN NPN NPN
1 P

3/5 E 2 B2 B2 B2 B2 B 3/5 E Communication M12 M12 M12 M12 M12 M12


4 A4 A4 A4 A4 A
connector
D-sub
Internal terminating
resistor
M Communication connector examples

3/5 E 2 B2 B2 B2 B2 B 3/5 E

4 A4 A4 A4 A4 A
M12 communication D-sub communication
connector connector
(PROFIBUS DP) (PROFIBUS DP)
SI unit
Fieldbus
Features 1
Series SY3000/5000 Pressure switch

Valve piping direction variations


M Piping is possible from 3 directions.
Top <Example of Use>
ported

Bottom
ported
By mounting top ported valves on
Side Side side ported and bottom ported type
ported ported manifolds, it is possible to detect the
output of the A/B port with a pressure
Mixed mounting of top ported and side ported is possible.
switch.

Valves can be freely connected up to 24 stations. Mixed valve sizes manifold


M It is possible to connect M Valves of different sizes,
only the number of valves SY3000 and SY5000, can
required, from 1 to 24 be mounted on the same
stations, to suit the manifold.
application.
(Maximum number of
solenoids connected: 32)

Series S0700 M It is possible to connect only the number of 7 mm


7 mm width valves can be width valves required, from 1 to 24 stations.
connected. (Maximum number of solenoids connected: 32)
Q Applicable Valve Series
Flow-rate characteristics (4/2→5/3) Maximum Power
Series number of consumption Enclosure Standards Page
C [dm3/(s·bar)] b solenoids (W)

SY3000 1.6 0.19 0.35 (standard)


32 0.1 (with power- IP67 page 7
saving circuit)
SY5000 3.6 0.17

S0700 0.37 0.39 32 0.35 IP40 page 38

SV1000 1.1 0.35

SV2000 2.4 0.18 32 0.6 IP67 page 24


®

SV3000 4.3 0.21

VQC1000 1.0 0.30


0.4 (standard)
VQC2000 3.2 0.30 24 IP67 page 29

VQC4000 7.3 0.38 1.0 (standard)

Note) For units with D-sub communication connector, it is IP40.


Features 2
Fieldbus System Variations IP67/65 specification models

I/O separated type I/O integrated type


Valve outputs only Gateway-type
Valve outputs Valve outputs
valve outputs only
Inputs only with multiple I/O’s with inputs
inputs only
Number of valve outputs

32
EX260

EX126 EX124

16 EX500
EX600 EX250
Number of inputs

16

32

Number of valve outputs 16 32 16 (total 64) 32 32


Number of inputs None 16 (total 64) 144 32
SI unit series EX260 EX126 EX124 EX260 EX500 EX600 EX250

PROFINET P P
EtherCAT P P P
EtherNet/IP™ P P P P P
Open network

PROFIBUS DP P P P P P
DeviceNet™ P P P P P P
CC-Link P P P P P P P
AS-Interface P
CANopen P
CompoNet™

SY 3000 P P P P P P
(Plug-in connector
connecting base) 5000 P P P P P P

S0700 0700 P P P P P
(Stacking base)
Applicable valve series

1000 P P P P P P
2000 P P P P P P
SV
3000 P P P P P P
4000 P
1000 P P P P P P
VQC 2000 P P P P P P
4000 P P P P P P
1000
2000 P
VQ
4000 P
5000 P

Features 3
Fieldbus System Variations IP20 specification models

I/O separated type I/O integrated type


Valve outputs only Gateway-type
Valve outputs Valve outputs
valve outputs only
Inputs only with multiple I/O’s with inputs
inputs only
Number of valve outputs

32
EX180

EX120 EX121 EX122 EX140

16
EX510
Number of inputs

16

32

Number of valve outputs 16 32 16 (total 64)


Number of inputs None 16 (total 64)
SI unit series EX120 EX121 EX122 EX140 EX180 EX510

PROFINET
EtherCAT
Open network

EtherNet/IP™
PROFIBUS DP P
DeviceNet™ P P P P P P
CC-Link P P P P P P
AS-Interface
CANopen
CompoNet™ P P P

SY 3000 P
(Plug-in connector
connecting base) 5000 P
2000 P P
SJ
3000 P P
SY 3000 P
(Plug-in
metal base) 5000 P
S0700 P P
(Bar stock) 0700
3000 P
SY 5000 P
(Bar stock)
7000 P
3000 P P P
Applicable valve series

SY 5000 P P P
(Stacking base)
7000 P
1000 P
2000 P
SV
3000 P
4000 P
1000 P P
2000 P P
VQ
4000
5000
1000 P P
SQ
2000 P P
SZ 3000 P P
1000 P
VQZ 2000 P
3000 P
3000 P
SYJ 5000 P
7000 P

Features 4
SI Unit Integrated-type/For Output
®

Series EX260
Note)

RoHS
Compact design Compact design for space saving

Number of outputs Each 32/16 digital output type available in the series

Output polarity Each negative common (PNP) / positive common (NPN) type available in the series

Enclosure IP67 (For units with D-sub connector, and when connected with S0700 manifolds, it is IP40.)

ON/OFF switching is possible with an internal terminating resistor for communication.


Internal terminating resistor (Only for units compatible with M12 PROFIBUS DP, CC-Link communication connectors)

SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000

D
D
D
D

Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.

How to Order SI Units

EX260 S PR1
Communication protocol
Symbol Protocol Number of outputs SI unit output polarity Communication connector Manifold symbol
DN1 Source/PNP (Negative common) QAN
32
DN2 Sink/NPN (Positive common) QA
DeviceNet™ M12
DN3 Source/PNP (Negative common) QBN
16
DN4 Sink/NPN (Positive common) QB
PR1 Source/PNP (Negative common) NAN
32
PR2 Sink/NPN (Positive common) NA
M12
PR3 Source/PNP (Negative common) NBN
16
PR4 Sink/NPN (Positive common) NB
PROFIBUS DP
PR5 Source/PNP (Negative common) NCN
32
PR6 Sink/NPN (Positive common) NC
D-sub Note)
PR7 Source/PNP (Negative common) NDN
16
PR8 Sink/NPN (Positive common) ND
MJ1 Source/PNP (Negative common) VAN
32
MJ2 Sink/NPN (Positive common) VA
CC-Link M12
MJ3 Source/PNP (Negative common) VBN
16
MJ4 Sink/NPN (Positive common) VB
EC1 Source/PNP (Negative common) DAN
32
EC2 Sink/NPN (Positive common) DA
EtherCAT M12
EC3 Source/PNP (Negative common) DBN
16
EC4 Sink/NPN (Positive common) DB
PN1 Source/PNP (Negative common) FAN
32
PN2 Sink/NPN (Positive common) FA
PROFINET M12
PN3 Source/PNP (Negative common) FBN
16
PN4 Sink/NPN (Positive common) FB
EN1 Source/PNP (Negative common) EAN
32
EN2 Sink/NPN (Positive common) EA
EtherNet/IP™ M12
EN3 Source/PNP (Negative common) EBN
16
EN4 Sink/NPN (Positive common) EB
Note) Enclosure is IP40 when the communication connector is D-sub.

1
Integrated-type/For Output Series EX260
SI Unit Specifications
Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4
Protocol PROFIBUS DP DeviceNet™ CC-Link
Applicable Volume 1(Edition 3.5)
Version Note 1) DP-V0
Volume 3(Edition 1.5)
Ver.1.10
system
Configuration file Note 3) GSD file EDS file —
SMJ1: 32/32 SMJ2: 32/32
I/O occupation area SPR1: 0/32 SPR2: 0/32 SPR5: 0/32 SPR6: 0/32 SDN1: 0/32 SDN2: 0/32 SMJ3: 32/32 SMJ4: 32/32
(Inputs/Outputs) SPR3: 0/16 SPR4: 0/16 SPR7: 0/16 SPR8: 0/16 SDN3: 0/16 SDN4: 0/16 (1 station, (1 station,

EX260
remote I/O stations) remote I/O stations)
9.6 k/19.2 k/45.45 k/93.75 k/ 156 k/625 k/
Communication speed 125 k/250 k/500 kbps
187.5 k/500 k/1.5 M/3 M/6 M/12 Mbps 2.5 M/5 M/10 Mbps
Power supply Power supply voltage 21.6 to 26.4 VDC — 21.6 to 26.4 VDC
for control Internal current consumption 100 mA or less — 100 mA or less
Power supply for output Power supply voltage — 22.8 to 26.4 VDC
Power supply for Power supply voltage — 11 to 25 VDC —
communication Internal current consumption 100 mA or less —
Communication connector specification M12 D-sub M12
Terminating resistor switch Built-in None Built-in
Source/PNP Sink/NPN Source/PNP Sink/NPN Source/PNP Sink/NPN Source/PNP Sink/NPN
Output type (Negative common) (Positive common) (Negative common) (Positive common) (Negative common) (Positive common) (Negative common) (Positive common)
SPR1: 32 points SPR2: 32 points SPR5: 32 points SPR6: 32 points SDN1: 32 points SDN2: 32 points SMJ1: 32 points SMJ2: 32 points
Number of outputs
SPR3: 16 points SPR4: 16 points SPR7: 16 points SPR8: 16 points SDN3: 16 points SDN4: 16 points SMJ3: 16 points SMJ4: 16 points

SY
Output Load Solenoid valve with protective circuit for surge voltage of 24 VDC/1.5 W or less (SMC)
Supplied voltage 24 VDC
SPR1: Max. 2.0 A SPR2: Max. 2.0 A SPR5: Max. 2.0 A SPR6: Max. 2.0 A SDN1: Max. 2.0 A SDN2: Max. 2.0 A SMJ1: Max. 2.0 A SMJ2: Max. 2.0 A
Supplied current
SPR3: Max. 1.0 A SPR4: Max. 1.0 A SPR7: Max. 1.0 A SPR8: Max. 1.0 A SDN3: Max. 1.0 A SDN4: Max. 1.0 A SMJ3: Max. 1.0 A SMJ4: Max. 1.0 A
Enclosure IP67 IP40 IP67
Operating temperature range 14 to 122°F (–10 to 50°C)
Environmental
Operating humidity range 35 to 85%RH (No condensation)
resistance
Withstand voltage 500 VAC for 1 minute between terminals and housing
Insulation resistance 10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Standards CE marking, UL (CSA) compatible
Weight 0.44 lbs (200 g)
Mounting screw 2 pcs.

SV
Accessories Seal cap (for M12
connector socket) EX9-AWTS (1 pc.) — EX9-AWTS (1 pc.)

Model EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4 EX260-SEN1/3 EX260-SEN2/4


Protocol EtherCAT Note 2) PROFINET Note 2) EtherNet/IP™ Note 2)
Applicable Conformance PROFINET Specification Volume 1(Edition 3.8)
system Version Note 1) Volume 2(Edition 1.9)
Test Record V.1.1 Version 2.2
Configuration file Note 3) XML file GSD file EDS file
I/O occupation area SEC1: 0/32 SEC2: 0/32 SPN1: 0/32 SPN2: 0/32 SEN1: 16/32 SEN2: 16/32
(Inputs/Outputs) SEC3: 0/16 SEC4: 0/16 SPN3: 0/16 SPN4: 0/16 SEN3: 16/16 SEN4: 16/16
Communication speed 100 Mbps Note 2) 10 M/100 Mbps Note 2)

VQC
Power supply Power supply voltage 21.6 to 26.4 VDC
for control Internal current consumption 100 mA or less
Power supply
for output Power supply voltage 22.8 to 26.4 VDC
Power supply for Power supply voltage —
communication Internal current consumption —
Communication connector specification M12
Terminating resistor switch None
Source/PNP Sink/NPN Source/PNP Sink/NPN Source/PNP Sink/NPN
Output type (Negative common) (Positive common) (Negative common) (Positive common) (Negative common) (Positive common)
Number of SEC1: 32 points SEC2: 32 points SPN1: 32 points SPN2: 32 points SEN1: 32 points SEN2: 32 points
outputs SEC3: 16 points SEC4: 16 points SPN3: 16 points SPN4: 16 points SEN3: 16 points SEN4: 16 points
Output Solenoid valve with protective circuit for surge Solenoid valve with protective circuit for surge Solenoid valve with protective circuit for surge
Load
S0700
voltage of 24 VDC/1.5 W or less (SMC) voltage of 24 VDC/1.0 W or less (SMC) voltage of 24 VDC/1.5 W or less (SMC)
Supplied voltage 24 VDC
Supplied voltage SEC1: Max. 2.0 A SEC2: Max. 2.0 A SPN1: Max. 2.0 A SPN2: Max. 2.0 A SEN1: Max. 2.0 A SEN2: Max. 2.0 A
SEC3: Max. 1.0 A SEC4: Max. 1.0 A SPN3: Max. 1.0 A SPN4: Max. 1.0 A SEN3: Max. 1.0 A SEN4: Max. 1.0 A
Enclosure IP67
Note 1) Please note that the
Operating temperature range 14 to 12°F (–10 to 50°C)
Environmental version is subject to
Operating humidity range 35 to 85%RH (No condensation) change.
resistance
Withstand voltage 500 VAC for 1 minute between terminals and housing Note 2) Use a CAT5 or higher
Insulation resistance 10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing transmission cable for
Standards CE marking, UL (CSA) compatible EtherCAT, PROFINET,
Weight 0.44 lbs (200 g) EtherNet/IP™.
Note 3) Each file can be
Mounting screw 2 pcs. downloaded from the SMC
Accessories Seal cap (for M12 website,
EX9-AWTS (1 pc.)
connector socket) http://www.smcworld.com

2
Series EX260
SI Unit Dimensions (mm)

M12 communication connector type D-sub communication connector type


90.9

90.9
102.4
102.4

28.2 21 20.6 16.4 9 28.2 28.75 29.25 9


76.5 76.5

Functions of SI Unit Parts


<LED indication and setting switch>

<Setting switch>
• Address switch
• Communication speed switch
• Terminating resistor switch Note) The setting switch varies depending on the model.
• Others Refer to the operation manual for details.
Please download it via the SMC website, http://www.smcworld.com

<LED indication>
• Communication state
• Unit power supply state
• Valve power supply state

<Connector>
M12 communication connector type
EX260-SECl
Part no. EX260-SPR1/-SPR2
-SPR3/-SPR4 EX260-SDNl EX260-SMJl EX260-SPNl
EX260-SENl
EtherCAT
Communication protocol PROFIBUS DP DeviceNet™ CC-Link PROFINET
EtherNet/IP™
Communication connector (M12) BUS OUT 5 pins, socket, B code 5 pins, socket, A code 5 pins, socket, A code 4 pins, socket, D code
Communication connector (M12) BUS IN 5 pins, plug, B code 5 pins, plug, A code 4 pins, plug, A code 4 pins, socket, D code
Ground terminal M3

Power connector (M12) 5 pins, plug, A code 4 pins, plug, A code 5 pinsNote1), 4 pinsNote2),
5 pins, plug, B code
plug, A code
Note 1) For EtherCAT, PROFINET
Note 2) For EtherNet/IP™
D-sub communication connector type
Part no. EX260-SPR5/-SPR6/-SPR7/-SPR8
Communication protocol PROFIBUS DP
Ground terminal M3
Communication connector (D-sub) BUS IN/OUT 9 pins, socket
Power connector (M12) 5 pins, plug, A code

3
Integrated-type/For Output Series EX260
Accessories

q Communication cable with connector


For SI units compatible
For SI units compatible with with EtherCAT, PROFINET,
PROFIBUS DP, DeviceNet™, CC-Link EtherNet/IP™

EX260
Refer to the catalog (CAT. NAS100-73)
for details. EX9 AC 020 EN PSRJ
Cable length (L) Connector specification
010 1000 [mm] PSRJ M12 plug (straight) ⇔ RJ-45 connector
020 2000 [mm]

ø6.7
030 3000 [mm] M12 RJ-45
050 5000 [mm]
100 10000 [mm]
47.3 L 45

Terminal Terminal Core wire 1


2 1 no. no. colors 2
3

SY
4
1 1 White 5
2 2 Orange Pair
6
3 4 3 3 White 7
4 4 Pair 8
5
Plug connector 6
7
Green Plug connector
pin arrangement 8 pin arrangement
Shield
D code
Connections (Straight cable)

For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™

SV
PCA 1446566
Cable length
1446566 5000 [mm]
ø14.8

47.3 5000 50
2 1

3 4
(ø6.5)

Terminal

VQC
Plug connector M12 no. Wire guide color
pin arrangement SPEEDCON Yellow: TD+
1
D code 2 White: RD+
3 Orange: TD–
4 Blue: RD–

Connections

For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™

Fieldwireable connector
S0700

PCA 1446553
ø17.5

≈ 61

2 1
ø19

3 4
Plug connector M12 Width across Width across flats 13
pin arrangement flats 16

D code

4
Series EX260
Accessories
w Power cable with connector (for SI units)
For SI units compatible with PROFIBUS DP, DeviceNet™, EtherCAT, PROFINET, EtherNet/IP™

EX500 AP 050 S
Cable length (L) Connector specification
010 1000 [mm] S Straight
050 5000 [mm] A Angle

Straight connector type Angle connector type

M12
ø14.9

M12

ø6
ø6

1 2 1 2

28.3
5 5

4 3 18 4 3 31.3 30 5
30 5
Socket connector 34 Socket connector L 50
48 50
pin arrangement pin arrangement
L
A code ø14.8 A code

SPEEDCON 44.5 L 50
5 1 2
PCA 1401804
Cable length (L) 4 3

ø5.0±0.15
M12
1401804 1500 [mm] Socket connector SPEEDCON
1401805 3000 [mm] pin arrangement
1401806 5000 [mm] A code
Terminal Core wire Terminal Core wire
no. colors no. colors
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply) 1 Brown: Not connected Note 1), 24 VDC ±10% (Control power supply) Note 2)
2 White: 0 V (Solenoid valve power supply) 2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 24 VDC ±10% (Control power supply) 3 Blue: Not connected Note 1), 0 V (Control power supply) Note 2)
4 Black: 0 V (Control power supply) 4 Black: 0 V (Solenoid valve power supply)
5 Gray: Not connected 5 Gray: Not connected
Note 1) For DeviceNet™
Connections (PROFIBUS DP/EtherCAT) Note 2) For EtherNet/IP™
Connections (DeviceNet™, EtherNet/IP™)

For SI units compatible with CC-Link


L
Straight connector type M12
48.1
1 2
5
EX9 AC 050 1
4 3
ø6.4

Cable length (L) 30 5


010 1000 [mm] Socket connector 50
030 3000 [mm] pin arrangement
050 5000 [mm] B code
ø14.8

44.5 L 50
SPEEDCON
5 1 2

PCA 1401807
4 3
ø5.0±0.15

Cable length (L) M12


1401807 1500 [mm] Socket connector SPEEDCON
pin arrangement Terminal Cable core
1401808 3000 [mm]
1401809 5000 [mm] B code no. wire colors
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
Connections 4 3 Blue: 24 VDC ±10% (Control power supply)
Black: 0 V (Control power supply)
5 Gray: Not connected

e Seal cap: For M12 connector socket


Use this on ports that are not being used for communication connector (M12
connector socket).
14

Use of this seal cap maintains the integrity of the IP67 enclosure.
Note) Tighten the seal cap with the prescribed tightening torque. (For M12: 0.07 lbf·ft (0.1 N·m)

EX9 AW TS
14

Connector type M12 x 1


10.2
TS For M12 connector socket (10 pcs.)
For M12 connector socket
5
Manifold Solenoid Valves for Series EX260 Integrated-type
(For Output) Serial Transmission System

EX260
Series SY3000/5000 Page 7

SY
Series SV1000/2000/3000 Page 24

SV
Series VQC1000/2000/4000 Page 29

VQC
Series S0700 Page 38

S0700

6
Plug-in Connector Connecting Base:
Type 10 For EX260 Integrated-type (For Output)
Side Ported Serial Transmission System
Type 11
Bottom Ported
Series SY3000/5000 RoHS

How to Order Manifold

Refer to page 11 for


Type 11/Bottom
SS5Y 3 10 S NA N 05 U C6
ported dimensions.
q w e r t y u i o
q Series t Valve stations y P, E port entry
3 SY3000 In the case of the 32-output SI unit U U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D D side (2 to 10 stations)
02 2 stations B Both sides (2 to 24 stations)
w Type Double wiring Note 1)
10 Side ported 16 16 stations u SUP/EXH block assembly
11 Bottom ported∗ 02 2 stations Nil Internal pilot
∗ The SY5000 manifold base is used for the bottom Specified layout Note 2) S Internal pilot, Built-in silencer
ported of the SY3000. When ordering, refer to Plug-in (Available up to 32 solenoids)
24 24 stations R External pilot
Mixed Type Manifold (from page 17).
In the case of the 16-output SI unit ∗ 3/5(E) port is plugged for the built-in silencer type.
e SI unit specifications Symbol Stations Note
∗ When the built-in silencer type is used, keep the
Symbol Protocol
Number of outputs Communication connector exhaust port from coming in direct contact with water or
02 2 stations other liquids.
0 Without SI unit
Double wiring Note 1)
QA
DeviceNet™
32
M12 08 8 stations o Mounting and Option
QB 16 02 2 stations Symbol Mounting Option
NA 32 Specified layout Note 2) Nil None
M12 Direct
NB PROFIBUS 16 (Available up to 16 solenoids) AA mounting Name plate (With station number)
16 16 stations
NC DP 32 BA Name plate (Without station number)
D-subNote) Note 1) Double wiring: 2-position single, double, 3-position
ND 16
and 4-position valves can be used on all manifold Dm Without name plate
DIN rail
VA
CC-Link
32
M12 stations. Am mounting
Name plate (With station number)
VB 16 Use of a 2-position single solenoid will result in an Bm Name plate (Without station number)
DA 32 unused control signal. If this is not desired, order Note 1) Enter the number of stations inside m. (Refer to
EtherCAT M12 with a specified layout.
DB 16 “DIN Rail Option” below.)
Note 2) Specified layout: Indicate the wiring specifications Note 2) Only direct mounting is available for Type 11
FA 32
PROFINET M12 on the manifold specification sheet. (Bottom ported).
FB 16 (Note that 2-position double, 3-position and
EA 32 DIN Rail Option
EtherNet/IP™ M12 4-position valves cannot be used where single
EB 16 wiring has been specified.) Nil Direct mounting
Note) IP40 for the D-sub applicable communication Note 3) Includes the number of blanking plate assemblies. 0 Without DIN rail (with bracket)
connector specification. Note 4) For the model without the SI unit (S0), note the 3 For 3 stations
maximum number of solenoids of the SI unit that Specify a longer rail than the total
For SI unit part number, refer to page 1.
DIN rail and SI unit output polarity “N” cannot be will be mounted. If the layout is specified, indicate length of specified stations.
24 For 24 stations
selected for the product without SI unit. it on the manifold specification sheet.
r SI unit output polarity ∗ When it is necessary to mount a DIN rail without an SI
unit, select D0 and order DIN rail length separately,
Nil Positive common Note 1) Ensure a match with the common specifications of the valve to be used. referring to L3 in the dimensions. Refer to the
N Negative common Note 2) Without SI unit, the symbol is nil. SY3000/5000 series catalog (CAT. NAS11-103) for part
numbers of DIN rail.
i A, B port size (Metric) A, B port size (Inch)
Type 10/ Type 11/ Type 10/ Type 11/
Side ported Bottom ported Side ported Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY5000 SY3000 SY5000 SY5000
C2 ø2 One-touch fitting P N1 ø1/8" One-touch fitting P
C3 ø3.2 One-touch fitting P N3 ø5/32" One-touch fitting P P P
Straight
Straight

C4 ø4 One-touch fitting P P N7 ø1/4" One-touch fitting P P P


C6 ø6 One-touch fitting P P P N9 ø5/16" One-touch fitting P P
C8 ø8 One-touch fitting P P CM∗ Straight port, mixed sizes P P P
CM∗ Straight port, mixed sizes P P P LN3 ø5/32" One-touch fitting P
Upward

L4 ø4 One-touch fitting P P LN7 ø1/4" One-touch fitting P P


Upward

L6 ø6 One-touch fitting P P LN9 ø5/16" One-touch fitting P


Elbow

L8 P BN3 P
Downward

ø8 One-touch fitting ø5/32" One-touch fitting


Elbow

B4 P P BN7 P P
Downward

ø4 One-touch fitting ø1/4" One-touch fitting


B6 ø6 One-touch fitting P P BN9 ø5/16" One-touch fitting P
B8 ø8 One-touch fitting P LM∗ Elbow port, mixed sizes
(Including upward and downward piping) P P
LM∗ Elbow port, mixed sizes
P P
(Including upward and downward piping) P, E port size (One-touch fittings) ø5/16" ø3/8" ø3/8"
P, E port size (One-touch fittings) ø8 ø10 ø10 ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”,
Note) To avoid interference with the body or piping, select downward elbow port
indicate it on the manifold specification sheet for the P, E port fitting direction.
when mounting the optional spacer assembly (Refer to the SY3000/ 5000
series catalog (CAT. NAS11-103)).
7
Plug-in Connector Connecting Base Series SY3000/5000
How to Order Manifold Assembly

Example (SS5Y3-10SNAN-l)
SS5Y3-10SNAN-04D-C6 ···1 set (Type 10 4-station manifold base part no.)
2-position single (24 VDC) 2-position double (24 VDC)
∗SY3100-5U1 ·····················2 sets (2-position single part no.)
SY3200-5U1 (1 set)
SY3100-5U1 (2 sets) ∗SY3200-5U1 ·····················1 set (2-position double part no.)
3-position closed center (24 VDC)
∗SY3300-5U1 ·····················1 set (3-position closed center part no.)
SY3300-5U1 (1 set)
∗The asterisk denotes the symbol for assembly.

EX260
∗Prefix it to the part nos. of the valve, etc.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above.
ide If the arrangement becomes complicated, specify on a manifold
Us specification sheet.
s
on
ati
St Note) When mixing top ported configurations, select from page 13. Specify
3
2 on a manifold specification sheet if plugs are required on the A and
1
B port on the manifold.
Manifold base (4 stations) ide
Ds
SS5Y3-10SNAN-04D-C6

Refer to the SY3000/5000 series catalog


How to Order Valves (With two mounting screws) (CAT.NAS11-103) for details on valve specifications.

SY
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series Pilot valve option !0 Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: Non-locking D: Push-turn
5 SY5000 B Quick response type (0.7 MPa) push type locking
K∗

SV
High pressure type (1.0 MPa) slotted
w Type of actuation ∗ Only metal seal type is available for the high pressure type
1 2-position single type.
2 2-position double
3 3-position closed center Coil type
4 3-position exhaust center Nil Standard E: F: Slide locking type
5 3-position pressure center T With power saving circuit (Continuous duty type) Push-turn
A∗ 4-position dual 3-port valve (N.C./N.C.) ∗ Be sure to select the power saving circuit type when a locking
B∗ 4-position dual 3-port valve (N.O./N.O.) valve is continuously energized for long periods of time. manual
∗ Note the specified energizing time when power saving type
C∗ 4-position dual 3-port valve (N.C./N.O.)
circuit is selected.
∗ Only rubber seal type is available for the

VQC
4-position dual 3-port valve.
Rated voltage
e Seal type 5 24 VDC !1 Type of mounting screw
0 Rubber seal Nil Round head combination screw
1 Metal seal Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification Round head combination screw
K (Falling-out-prevention type)
r Pilot type R With surge voltage suppressor (Non-polar)
Hexagon socket head cap screw
Nil Internal pilot U With light/surge voltage suppressor (Non-polar) H (Falling-out-prevention type)
R External pilot S With surge voltage suppressor (Positive common)
Z With light/surge voltage suppressor (Positive common) ∗ For “K” and “H”, the valve body cover has a drop
prevention construction to stop the mounting screws
t Back pressure check valve NS With surge voltage suppressor (Negative common) from falling out when the valve is removed for
S0700
(Built-in valve type) NZ With light/surge voltage suppressor (Negative common) maintenance etc.
∗ When ordering a valve individually, the base gasket
Nil None ∗ Only “Z” and “NZ” types are available for the product with
is not included. Since the base gasket is attached to
H Built-in power saving circuit. Select a valve from R, U, S or Z when the manifold, please order the base gasket
the SI unit output polarity is Nil (Positive common). separately if it is needed for maintenance service.
∗ Only rubber seal type.
Manifold installed type is available if the back
Select a valve from R, U, NS or NZ when the SI unit output Refer to the SY3000/5000 series catalog
pressure check valve is required for a valve with polarity is N (Negative common). (CAT.NAS11-103) for part numbers of the base
metal seal. Refer to the SY3000/5000 series catalog gasket and mounting screw.
(CAT.NAS11-103) for details. However, it is not ∗ “B” and “H” cannot be selected for the individual
recommended to use the built-in valve type and the SUP/EXH spacer assembly or double check spacer
manifold installed type at the same time because it assembly with residual pressure release valve.
will reduce the flow.
∗ The built-in valve type back pressure check valve is
not available for the 3-position type.

Refer to the SMC website or the SY3000/5000 series catalog (CAT.NAS11-103) for details on Protective class
solenoid valve specifications, Common Precautions and Specific Product Precautions. class (Mark: )

8
Series SY3000/5000
Dimensions: Type 10/For EX260/Series SY3000 (mm)
C2
U C3, N1
SS5Y3-10Sll- Stations DB (S, R) - C4, N3 (D)
C6, N7

D side U side
Manual override
DIN rail holding screw
(For DIN rail mounting)
(L5) L1
(Push-turn locking slotted type:
Press, then rotate it. )
Light/surge voltage suppressor 4(A) port side: Blue (For rubber seal)
Silencer (exhaust port) : Gray (For metal seal)
(Built-in silencer specification) 2(B) port side: Yellow
DIN rail 8

5.5
B A B A B A B A B A

92.6
35
14 A 14 A 14 A 14 A 14 A

83
(114.8)
80.2

60.5
40.9
12 B 12 B 12 B 12 B 12 B

4.6
22.2

4.6
1.7
(4.9)
SI unit 4 x M4 mounting hole

N7:7.4 )
( C6:3.6 (Fitting for the type with P/E
ports on U and/or D sides)
34.7 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting
[External pilot] One-touch fitting
[4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2
42.3 7.4 Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
(Station 1)----------- (Station n)
: ø4, ø5/32"
: ø6, ø1/4"

manual override)
BUS OUT

(Slide locking
PE 1 P 1 P
76.7

X
68.8
63.1
10.6
13.6

B A B A BUS IN
56.6

14 A 14 A
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

PWR 4 A4 A4 A4 A4 A
21.6
18
(42.8)
(37.5)

1P
12 B 12
(For DIN rail
mounting)
7.5

46.5 15.5 (Pitch) (17.8)


11.8

One-touch fitting P = 10.5


[PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32"

[Communication connector D-sub]

BUS OUT BUS


1 P 1 P
82.3
78.6

BUS IN
3/5 E 2 B2 3/5 E 2 B2

PWR 4 A4
PWR 4 A4

Note) These figures show the “SS5Y3-10SQA-05D-C6”.

n: stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275 287.5 300 312.5 325 337.5 337.5 350
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16 17 12 13

9
Plug-in Connector Connecting Base Series SY3000/5000
Dimensions: Type 10/For EX260/Series SY5000 (mm)

U C4, N3
SS5Y5-10Sll- Stations DB (S, R) - C6, N7 (D)
C8, N9

D side U side
Manual override
DIN rail holding screw (L5)
(
Push-turn locking slotted type:
)

EX260
L1
(For DIN rail mounting) Press, then rotate it.
4(A) port side: Blue (For rubber seal)
Silencer (exhaust port) : Gray (For metal seal)
Light/surge voltage suppressor
(Built-in silencer specification) 2(B) port side: Yellow
DIN rail 8

5.5
B A B A B A B A B A

35
14 A 14 A 14 A 14 A 14 A

(114.8)

97.5
113.4
101

81.2
61.7

SY
5.5
12 B 12 B 12 B 12 B 12 B

10.9
1.4

4.7
(5.9)
(8.3)
(Fitting for the type with
SI unit P/E ports on U and/or D sides) 4 x M5 mounting hole

34.2 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

SV
[External pilot] One-touch fitting One-touch fitting
50.5 (20°) [1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø10, ø3/8" (Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

manual override)
(Slide locking
PE BUS OUT

3/5 B A B A

78.9
14.1
76.7

1 P 1 P
14 A 14 A
BUS IN 2 B2 B2 B2 B2 B 73.2
56.6
12.4

E
X 3/5 3/5
33.4

E E
29.1

1 PWR
(59.8)

4 A4 A4 A4 A4 A

VQC
P
(31.7)

12 B 12
8.7

(For DIN rail


mounting)

(Pitch) (20.5)
7.5

48.2 18
11.8

P = 16
One-touch fitting
[PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32"
[Communication connector D-sub]

BUS OUT BUS


74.5

1 P 1 P
70.8

S0700
BUS IN 2 B2 2 B2

3/5 E 3/5 E
PWR PWR

4 A4 4 A4

Note) These figures show the “SS5Y5-10SQA-05D-C8”.

n: Station 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375 400 412.5 425 437.5 462.5 475 487.5
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5 12.5

10
Series SY3000/5000
Dimensions: Type 11/For EX260/Series SY5000 (mm)

U C4, N3
SS5Y5-11Sll- Stations DB (S, R) - C6, N7
C8, N9
D side U side
Manual override

Silencer (exhaust port)


L1 (
Push-turn locking slotted type:
Press, then rotate it. )
(Built-in silencer specification) 4(A) port side: Blue (For rubber seal)
Light/surge voltage suppressor : Gray (For metal seal)
DIN rail 2(B) port side: Yellow

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

(114.8)

97.5
113.4
116.7
101

81.2
5.5
12 B 12 B 12 B 12 B 12 B

10.9
1.4
34.2 L2 1.5
4 x M5 mounting hole
[Communication connector D-sub] (Station 1)----------- (Station n)

manual override)
(Slide locking
BUS BUS OUT

78.9
76.7

73.2
BUS IN

56.6
8.7
PWR PWR

4.7
(12.9)

(9.5)
(Fitting for the type with P/E
ports on U and/or D sides)

[External pilot] 48.2 18 (Pitch) (20.5)


4.7

(20°) P = 16
50.5
31.8

39.7
3/5 E 3/5 E
2 B2 B2 B2 B2 B
18

PE
15

3/5 B A B A
14 A 14 A 1 P 1 P
4 A4 A4 A4 A4 A
E
X
1
(59.8)

Cut dimensions for panel mounting


P
Refer to panel cut dimensions
(31.7)

12 B 12
for details.
One-touch fitting One-touch fitting
[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø10, ø3/8" Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[PE: Pilot EXH port]
[X: External pilot port] Panel cut dimensions
Applicable tube O.D.C4: ø4(SMC)
N3: ø5/32"(SMC)
7
60
97.5

BUS OUT
74.5
70.8

BUS IN

PWR

L2 4 x M5 hole
4 x ø5.5
Note) These figures show the “SS5Y5-11SQA-05D-C8”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432

11
Plug-in Connector Connecting Base:
For EX260 Integrated-type (For Output)
Serial Transmission System
Type 12
Top Ported
Series SY3000/5000
RoHS

How to Order Manifold

Refer to pages 15,


16 for Type 12/Top
SS5Y 3 12S NA N 05 U
ported dimensions.
q w e r t y u i
q Series r Valve stations y SUP/EXH block assembly
3 SY3000 In the case of the 32-output SI unit Nil Internal pilot
5 SY5000 Symbol Stations Note S Internal pilot, Built-in silencer
02 2 stations R External pilot

Double wiring Note 1) ∗ For built-in silencer type, P and E ports are
w SI unit specifications 16 16 stations available on U and D sides. 3/5(E) port is
Number of Communication 02 2 stations plugged. The silencer exhaust port is located
Symbol Protocol outputs connector Specified layout Note 2) on the opposite side of P, E port entry.

0 Without SI unit (Available up to 32 solenoids) (Example: When the P, E port entry is D side,
24 24 stations
QA 32 the silencer exhaust port is U side.)
DeviceNet™ M12 In the case of the 16-output SI unit
QB 16 ∗ When the built-in silencer type is used, keep
Symbol Stations Note
NA 32 the exhaust port from coming in direct contact
M12 02 2 stations
NB PROFIBUS 16 with water or other liquids.

Double wiring Note 1)


NC DP 32
D-sub Note) 08 8 stations
ND
VA
16
32
02 2 stations
Specified layout Note 2)
u P, E port size (One-touch fittings)
CC-Link M12

VB 16 (Available up to 16 solenoids) Symbol SY3000 SY5000


DA 32
16 16 stations Nil ø8 ø10
EtherCAT M12 Note 1) Double wiring: 2-position single, double, N ø5/16" ø3/8"
DB 16
FA 32 3-position and 4-position valves can be ∗ For N, sizes are in inches.
PROFINET M12 used on all manifold stations.
FB 16
Use of a 2-position single solenoid will
EA 32
EB
EtherNet/IP™
16
M12 result in an unused control signal. If this is i Mounting
not desired, order with a specified layout.
Nil Direct mounting
Note) IP40 for the D-sub applicable communication Note 2) Specified layout: Indicate the wiring
connector specification. specifications on the manifold specification
D DIN rail mounting (With DIN rail)
For SI unit part number, refer to page 1. sheet. D0 DIN rail mounting (Without DIN rail)
DIN rail and SI unit output polarity “N” cannot (Note that 2-position double, 3-position D3 For 3 stations
Specify a longer rail than

be selected for the product without SI unit. and 4-position valves cannot be used the standard length.
where single wiring has been specified.) D24 For 24 stations
Note 3) Includes the number of blanking plate
e SI unit output polarity assemblies.
∗ When it is necessary to mount a DIN rail
without an SI unit, select D0 and order DIN
Nil Positive common Note 4) For the model without the SI unit (S0), rail length separately, referring to L3 in the
N Negative common note the maximum number of solenoids of dimensions. Refer to the SY3000/5000 series
Note 1) Ensure a match with the common the SI unit that will be mounted. If the catalog (CAT.NAS11-103) for part numbers of
specifications of the valve to be used. layout is specified, indicate it on the DIN rail.
Note 2) Without SI unit, the symbol is nil. manifold specification sheet.

t P, E port entry
U Note) U side (2 to 10 stations)
D Note) D side (2 to 10 stations)
B Both sides (2 to 24 stations)
Note) y For type “S”, supply/exhaust block
assembly with built-in silencer, choose U or
D for P port entry.

13
Plug-in Connector Connecting Base Series SY3000/5000
How to Order Manifold Assembly

Example (SS5Y3-12SNAN-l)
2-position single (24 VDC) 2-position double (24 VDC) SS5Y3-12SNAN-04D ········· 1 set (Type 12 4-station manifold base part no.)
SY3130-5U1-C6 (2 sets) SY3230-5U1-C6 (1 set)
∗SY3130-5U1-C6 ················ 2 sets (2-position single part no.)
3-position closed center (24 VDC) ∗SY3230-5U1-C6 ················ 1 set (2-position double part no.)
SY3330-5U1-C6 (1 set) ∗SY3330-5U1-C6 ················ 1 set (3-position closed center part no.)

EX260
∗ The asterisk denotes the symbol for assembly.
∗ Prefix it to the part nos. of the valve, etc.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
ide from the 1st station as shown in the figure above.
s
Us
tion If the arrangement becomes complicated, specify on a manifold
Sta
specification sheet.

3
2
1

Manifold base (4 stations) ide


Ds
SS5Y3-12SNAN-04D

Refer to the SY3000/5000 series catalog


How to Order Valves (With two mounting screws) (CAT.NAS11-103) for details on valve specifications.

SY
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
!1 A, B port size
q Series y Pilot valve option Thread piping
3 SY3000 Nil Standard (101 psi (0.7 MPa)) Symbol Port size Applicable series
5 SY5000 B Quick response type (101 psi (0.7 MPa)) M5 M5 x 0.8 SY3000
K∗ High pressure type (145psi (1.0 MPa)) 01 1/8 SY5000
w Type of actuation
∗ Only metal seal type is available for the high pressure type. One-touch fitting (Metric)

SV
1 2-position single
2 2-position double u Coil type Symbol A and B port SY3000 SY5000
Nil Standard C2 ø2 One-touch fitting P
3 3-position closed center
T With power saving circuit (Continuous duty type) C3 ø3.2 One-touch fitting P
4 3-position exhaust center
C4 ø4 One-touch fitting P P
5 3-position pressure center ∗ Be sure to select the power saving circuit type when a
C6 ø6 One-touch fitting P P
A∗ 4-position dual 3-port valve (N.C./N.C.) valve is continuously energized for long periods of time.
∗ Note the specified energizing time when power saving C8 ø8 One-touch fitting P
B∗ 4-position dual 3-port valve (N.O./N.O.)
circuit is selected. One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.)
∗ Only rubber seal type is available for the 4-position dual 3-port valve. i Rated voltage Symbol A and B port SY3000 SY5000
5 24 VDC N1 ø1/8" One-touch fitting P
e Seal type N3 ø5/32" One-touch fitting P P
0 Rubber seal o Light/surge voltage suppressor and common N7 ø1/4" One-touch fitting P P

VQC
specification
1 Metal seal N9 ø5/16" One-touch fitting P
R With surge voltage suppressor (Non-polar)
r Pilot type U With light/surge voltage suppressor (Non-polar) !2 Thread type
Nil Internal pilot S With surge voltage suppressor (Positive common) Nil Rc
R External pilot Z With light/surge voltage suppressor (Positive common) F G
NS With surge voltage suppressor (Negative common) N NPT
t Back pressure check valve NZ With light/surge voltage suppressor (Negative common) T NPTF
(Built-in valve type) ∗ Only “Z” and “NZ” types are available for the product with ∗ Only Nil is available for M5.
Nil None power saving circuit. Select a valve from R, U, S or Z when
H Built-in the SI unit output polarity is Nil (Positive common). !3 Type of mounting screw
Select a valve from R, U, NS or NZ when the SI unit output Nil Round head combination screw
∗ Only rubber seal type.
polarity is N (Negative common). B Hexagon socket head cap screw
Manifold installed type is available if the back
S0700
K Round head combination screw(Falling-out-prevention type)
pressure check valve is required for a valve with
metal seal. Refer to the SY3000/5000 series catalog
!0 Manual override
H Hexagon socket head cap screw(Falling-out-prevention type)
(CAT. NAS11-103) for details. However, it is not Nil: D: ∗ For “K” and “H”, the valve body cover has a drop
recommended to use the built-in valve type and the Non-locking Push-turn prevention construction to stop the mounting screws
manifold installed type at the same time because it push type locking slotted from falling out when the valve is removed for
will reduce the flow. type maintenance etc.
∗ The built-in valve type back pressure check valve is ∗ When ordering a valve individually, the base gasket
not available for the 3-position type. is not included. Since the base gasket is attached to
the manifold, please order the base gasket
E: F: separately if it is needed for maintenance service.
Push-turn Slide locking Refer to the SY3000/5000 series catalog
Refer to the SMC website or the SY3000/5000 locking type (CAT.NAS11-103) for part numbers of the base
series catalog (CAT.NAS11-103) for details on manual gasket and mounting screw.
solenoid valve specifications, Common type ∗ “B” and “H” cannot be selected for the individual
SUP/EXH spacer assembly.
Precautions and Specific Product Precautions.
Protective class
class (Mark: )
14
Series SY3000/5000
Dimensions: Type 12/For EX260/Series SY3000 (mm)

U
SS5Y3-12Smm- Stations D
B
(S, R) (-D)
Manual override
D side U side
Push-turn locking slotted type:
(
Press, then rotate it. )
(L5) L1 4(A) port side : Blue (For rubber seal)
DIN rail holding screw : Gray (For metal seal)
(For DIN rail mounting) Light/surge voltage suppressor 2(B) port side : Yellow
One-touch fitting 46 16 (Pitch)
[1(P), 3/5(E) port] P = 10.5 Silencer (exhaust port)
Applicable tube O.D.: ø8, ø5/16" 8 (Built-in silencer specification)

DIN rail

5.5
PE
X
3/5E B A B A B A B A B A

92.6
4A 4A 4A 4A 4A

35

83
(114.8)
80.2

15

11
60.5
40.9
1P
31.8

30.2
2B 2B 2B 2B 2B

4.6
22.2

4.6
4 x M4 mounting hole

1.7
SI unit 34.7 L2 1.5 M5 x 0.8
5.3 L4 [4(A), 2(B) port]
(DIN rail mounting hole pitch: 12.5)
One-touch fitting
L3
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
[External pilot] : ø6, ø1/4"

One-touch fitting (Station 1) (Station n)


[PE: Pilot EXH port] (15.3) (Fitting for the type with P/E
[X: External pilot port] ports on U and/or D sides)
Applicable tube O.D.: ø4, ø5/32"

manual override)
BUS OUT
7.4
(Slide locking

N7: 81.1 )
77.3
1 P 1 P
(73.8)
76.7

68.8
63.1

BUS IN
56.6

( C6:
5.3

13.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E

PE PWR
4 A4 A4 A4 A4 A
X
3/5E B A B A
4A 4A
58.5

(For DIN rail


7.5

mounting)
11.8

1P
2B 2

[Communication connector D-sub]

BUS OUT BUS


1 P 1 P
(73.2)

BUS IN
3/5 E 2 B2 3/5 E 2 B2

PWR PWR
4 A4 4 A4

Note 1) These figures show the “SS5Y3-12SQA-05D”.


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.

n:Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275 287.5 300 312.5 325 337.5 337.5 350
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16 17 12 13

15
Plug-in Connector Connecting Base Series SY3000/5000
Dimensions: Type 12/For EX260/Series SY5000 (mm)

U
SS5Y5-12Smm- Stations D
B
(S, R) (-D) D side U side
Manual override

(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(L5) L1 : Gray (For metal seal)
2(B) port side : Yellow

EX260
DIN rail holding screw
Light/surge voltage suppressor
(For DIN rail mounting)
45.1 21.1 (Pitch) Silencer (exhaust port)
One-touch fitting P = 16 (Built-in silencer specification)
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8" 8

DIN rail

5.5
PE
3/5 B A B A B A B A B A
4A 4A 4A 4A 4A

35
(114.8)

97.5
113.4
116.7
26.5
E
101

X
1

81.2
61.7

Cm: 14.5
01: 16.2
P

SY
47.3
5.5
39.5

2B 2B 2B 2B 2B
1.4

4 x M5 mounting hole

10.9
2.7
4.7

1/8
SI unit 34.2 L2 1.5 [4(A), 2(B) port]

5.3 L4 One-touch fitting


(DIN rail mounting hole pitch: 12.5) [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
L3
: ø6, ø1/4"
[External pilot] : ø8, ø5/16"

5.4

SV
(Station 1) (Station n) (Fitting for the type with P/E
(17.4) ports on U and/or D sides)

PE
3/5 B A B A

manual override)
26.9

4A 4A

(Slide locking
BUS OUT

(91.3)
E 78.9
X
76.9
76.7

(69.7)

1 P 1 P
73.2

1
BUS IN 2 B2 B2 B2 B2 B
56.6
52.8

P 3/5 E 3/5 E
PWR
2B 2

4 A4 A4 A4 A4 A

VQC
8.7

(For DIN rail

One-touch fitting
mounting)
7.5

[PE: Pilot EXH port]


11.8

[X: External pilot port]


Applicable tube O.D.: ø4, ø5/32"
[Communication connector D-sub]

BUS OUT BUS

1 P 1 P
(65.4)

BUS IN 2 B2 2 B2
S0700
3/5 E 3/5 E
PWR PWR

4 A4 4 A4

Note 1) These figures show the “SS5Y5-12SQA-05D”.


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.

n:Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375 400 412.5 425 437.5 462.5 475 487.5
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5 12.5

16
Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
Type 10 For EX260 Integrated-type (For Output)
Side Ported Serial Transmission System
Type 11
Bottom Ported
Series SY3000/5000 RoHS

SY3000 can be mounted onto SY5000 size manifold. How to Order Manifold
Refer to page 20 for Type 11/
Bottom ported dimensions. SS5Y5 M 10 S NA N 05 U C 8 6
Mixed Mounting Type
It is possible to mount SY3000 size valves on all stations.
In this case, there is no need to fill in part i in the order
q w e r t y u i o !0
code. However, the manifold block width should be 12.5 mm.

q Type e SI unit output polarity


10 Side ported Nil Positive common
11 Bottom ported N Negative common
Note 1) Ensure a match with the common specifications of the valve to be used.
w SI unit specifications Note 2) Without SI unit, the symbol is nil.
Symbol Protocol Number of outputs Communication connector
0 Without SI unit r Valve stations
QA 32 In the case of the 32-output SI unit In the case of the 16-output SI unit
DeviceNet™ M12
QB 16 Symbol Stations Note Symbol Stations Note
NA 32 02 2 stations 02 2 stations
M12
NB PROFIBUS 16 Double wiring Note 1) Double wiring Note 1)
NC DP 32 16 16 stations 08 8 stations
D-sub Note) 02 2 stations 02 2 stations
ND 16
Specified layout Note 2) Specified layout Note 2)
VA 32 (Available up to 32 solenoids) (Available up to 16 solenoids)
CC-Link M12
VB 16 24 24 stations 16 16 stations
DA 32 Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold
EtherCAT M12
DB 16 stations.
FA 32 Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a
PROFINET M12 specified layout.
FB 16
Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet.
EA 32 (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been
EtherNet/IP™ M12
EB 16 specified.)
Note) IP40 for the D-sub applicable communication connector specification. Note 3) Includes the number of blanking plate assemblies.
For SI unit part number, refer to page 1. Note 4) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be
DIN rail and SI unit output polarity “N” cannot be selected for the mounted. If the layout is specified, indicate it on the manifold specification sheet.
product without SI unit.
How to Order Manifold Assembly t P, E port entry y SUP/EXH block assembly
U U side (2 to 10 stations) Nil Internal pilot
D D side (2 to 10 stations) S Internal pilot, Built-in silencer
Example (SS5Y5-M10SNAN-l) B Both sides (2 to 24 stations) R External pilot
2-position double
∗ 3/5(E) port is plugged for the built-in
2-position double SY3200-5U1(2 sets) silencer type.
SY5200-5U1(3 sets) Manifold base (5 stations) ∗ When the built-in silencer type is used,
SS5Y5-M10F1-05D-C86 keep the exhaust port from coming in
direct contact with water or other liquids.

Refer to the page on the right for u,i,o

!00 Mounting and Option


ide
Us Symbol Mounting Option
s
on Nil None
ati Direct
St
AA Name plate (With station number)
mounting
3

BA Name plate (Without station number)


2
1

ide Dl Without name plate


Ds DIN rail
Al mounting
Name plate (With station number)
SS5Y5-M10F1-05D-C86 ···1 set (Type 10 5-station manifold base part no.) Bl Name plate (Without station number)
∗SY5200-5U1 ·····················3 sets (2-position double part no.)
Note 1) Enter the number of stations inside m.
∗SY3200-5U1 ·····················2 sets (2-position double part no.) (Refer to “DIN Rail Option” below.)
∗The asterisk denotes the symbol for assembly. Note 2) Only direct mounting is available for Type 11 (Bottom ported).
∗Prefix it to the part nos. of the valve, etc. DIN Rail Option
• The valve arrangement is numbered as the 1st station from the D side. Nil Standard length
• Under the manifold part number, state the valves to be mounted in order from the 1st station
0 Without DIN rail (with bracket)
as shown in the figure above.
If the arrangement becomes complicated, then indicate on the manifold specification sheet. 3 For 3 stations Specify a longer rail than the total length of specified
stations. [The SY5000 valve is now at a mountable length
Note ) When mounting top ported valves, select from page 21. In this case, use 24 For 24 stations (manifold block length of 16 mm).]
caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and ∗ When it is necessary to mount a DIN rail without an SI unit, select D0 and
B port on base side. calculate DIN rail length, referring to L3 in the dimensions on page 19.

17
Plug-in Connector Connecting Base Series SY3000/5000

u Fitting type i SY5000: A, B port size


Symbol A, B port

EX260
(Metric) (Inch)
C Metric size: Straight one-touch fitting Symbol Port size Symbol Port size
L Metric size: Elbow one-touch fitting for upward Note) 4 ø4 One-touch fitting 3 ø5/32" One-touch fitting
B Metric size: Elbow one-touch fitting for downward Note) 6 ø6 One-touch fitting 7 ø1/4" One-touch fitting
N Inch size: Straight one-touch fitting 8 ø8 One-touch fitting 9 ø5/16" One-touch fitting
LN Inch size: Elbow one-touch fitting for upward Note) Nil For all stations of SY3000 Nil For all stations of SY3000
BN Inch size: Elbow one-touch fitting for downward Note) ∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected.
CM∗ Straight port, mixed sizes
LM∗ Elbow port, mixed sizes (Including upward and downward piping) Note) o SY3000: A, B port size
Note) To avoid interference with the body or piping, select downward elbow port (Metric) (Inch)
when mounting the optional spacer assembly. Symbol Port size Symbol Port size
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”. 2 ø2 One-touch fitting 1 ø1/8" One-touch fitting
∗ The direction of P, E port fittings is the same as for A,B port. 3 ø3.2 One-touch fitting 3 ø5/32" One-touch fitting
If selecting “LM”, indicate it on the manifold specification sheet for the P, E port

SY
4 ø4 One-touch fitting 7 ø1/4" One-touch fitting
fitting direction.
∗ Elbow fittings: ø2, ø3.2 and ø1.8" are not available for the SY3000 series. ø2,
6 ø6 One-touch fitting
ø3.2, ø1.8" and ø5/32" are not available for the SY5000 series. ∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected.
Refer to the SY3000/5000 series catalog
How to Order Valves (With two mounting screws) (CAT.NAS11-103) for details on valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

SV
q Series y Pilot valve option !00 Manual override
3 SY3000 Nil Standard (101 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (101 psi (0.7 MPa)) Non-locking Push-turn
K∗ High pressure type (145 psi (1.0 MPa)) push type locking
w Type of actuation ∗ Only metal seal type is available for the high pressure type. slotted
1 2-position single type
2 2-position double u Coil type
3 3-position closed center Nil Standard
4 3-position exhaust center T With power saving circuit (Continuous duty type) E: F:
5 3-position pressure center ∗ Be sure to select the power saving circuit type when a Push-turn Slide locking
A∗ locking type

VQC
4-position dual 3-port valve (N.C./N.C.) valve is continuously energized for long periods of time.
B∗ 4-position dual 3-port valve (N.O./N.O.) ∗ Note the specified energizing time when power saving manual
C∗ 4-position dual 3-port valve (N.C./N.O.) circuit is selected. type
∗ Only rubber seal type is available for the
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
e Seal type !1 Type of mounting screw
0 Rubber seal
o Light/surge voltage suppressor Nil Round head combination screw
and common specification B Hexagon socket head cap screw
1 Metal seal
Nil Without light/surge voltage suppressor (Non-polar) K Round head combination screw (Falling-out-prevention type)
r Pilot type R With surge voltage suppressor (Non-polar) H Hexagon socket head cap screw (Falling-out-prevention type)
Nil Internal pilot U With light/surge voltage suppressor (Non-polar) ∗ For “K” and “H”, the valve body cover has a drop
S With surge voltage suppressor (Positive common)
S0700
R External pilot prevention construction to stop the mounting screws from
Z With light/surge voltage suppressor (Positive common) falling out when the valve is removed for maintenance
t Back pressure check valve NS With surge voltage suppressor (Negative common) etc.
∗ When ordering a valve individually, the base gasket is not
(Built-in valve type) NZ With light/surge voltage suppressor (Negative common)
included. Since the base gasket is attached to the
Nil None ∗ Only “Z” and “NZ” types are available for the product manifold, please order the base gasket separately if it is
H Built-in with power saving circuit. Select a valve from R, U, S or needed for maintenance service.
Z when the SI unit output polarity is Nil (Positive Refer to the SY3000/5000 series catalog
∗ Only rubber seal type.
Manifold installed type is available if the back common). (CAT.NAS11-103) for part numbers of the base gasket
pressure check valve is required for a valve with Select a valve from R, U, NS or NZ when the SI unit and mounting screw.
metal seal. Refer to the SY3000/5000 series catalog output polarity is N (Negative common). ∗ “B” and “H” cannot be selected for the individual SUP/EXH
(CAT.NAS11-103) for details. However, it is not spacer assembly or double check spacer assembly with
recommended to use the built-in valve type and the residual pressure release valve.
manifold installed type at the same time because it
will reduce the flow.
∗ The built-in valve type back pressure check valve is Refer to the SMC website or the SY3000/5000 series catalog (CAT.NAS11-103) for details
not available for the 3-position type. on solenoid valve specifications, Common Precautions and Specific Product Precautions.

18
Series SY3000/5000
Dimensions: Type 10/For EX260/Mixed Mounting Type (mm)

U
SS5Y5-M10Sll- Stations DB (-D)

D side U side Manual override

(L5) L1 (Push-turn locking slotted type:


Press, then rotate it. )
DIN rail holding screw 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
Light/surge voltage suppressor
DIN rail 8

5.5
B A B A B A B A B A
14 A 14 A

35
14 A 14 A 14 A
(114.8)
97.5

113.4
101

81.2
12 B 12 B

61.7
5.5
12 B 12 B 12 B
10.9
1.4

4.7
(5.9)
(8.3)

SI unit (Fitting for the type with P/E 4 x M5 mounting hole


ports on U and/or D sides)
34.2 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

One-touch fitting One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø2
: ø6, ø1/4" : ø3.2, ø1/8"
: ø8, ø5/16" : ø4, ø5/32"
(Station 1) (Station n) : ø6, ø1/4"
(SY3000)

(SY5000)

manual override)
(Slide locking
11.1

14.1

BUS OUT
78.9
76.7

1 P 1 P
73.2

BUS IN 2 B2 B2 B2 B2 B
56.6

12.4

(SY3000)
(SY5000)

3/5 3/5
33.4

E 4 E
31.5

A4 A4 A
29.1

PWR 4 A4 A
8.7

(For DIN rail


7.5

mounting)

One-touch fitting (20.5)


11.8

[1(P), 3/5(E) port] (Pitch of SY3000)


Applicable tube O.D.: ø10, ø3/8" P = 12.5
(Pitch of SY5000)
48.2 18 P = 16

Note 1) These figures show the “SS5Y5-M10SQA-05D-C86”.


Note 2) Refer to page 10 for dimensions of D-sub communication connector,
external pilot and built-in silencer.

EX260 Serial transmission Calculation of dimensions


L1 = 12.5 x n1 + 16 x n2 + 88.7
L2 = 12.5 x n1 + 16 x n2 + 48
M = L1/12.5 + 1 Remove all numbers after the decimal
L3 = 12.5 x M + 23
L4 = L3 − 10.5
L5 = (L3 − L1)/2
n1: SY3000 Valve stations
n2: SY5000 Valve stations

19
Plug-in Connector Connecting Base Series SY3000/5000
Dimensions: Type 11/For EX260/Mixed Mounting Type (mm)

U Manual override
SS5Y5-M11Smm- Stations D D side U side
B

L1
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
Light/surge voltage suppressor
2(B) port side : Yellow

SI unit 4 x M5 mounting hole

EX260
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

(114.8)

97.5
113.4
101

81.2
12 B 12 B

5.5
12 B 12 B 12 B

10.9
1.4

4.7
34.2 L2 1.5

SY
(Station 1) (Station n)

manual override)
(Slide locking
BUS OUT

78.9
76.7

73.2
BUS IN

56.6
8.7
PWR

4.7

(SY3000)
(12.9)

(SY5000)

(Fitting for the type with P/E

SV
(7.3)
(9.5)

ports on U and/or D sides)

(Pitch of SY5000)
48.2 18 P = 16
(Pitch of SY3000)
P = 12.5
(20.5)
4.7

Panel cut dimensions


(SY5000)

(SY3000)
31.8

39.7
7

49.6

3/5 E 3/5 E

VQC
2 B2 B2 B
18

2 B2 B
60
97.5

1 P 1 P
4 A4 A4 A
(SY5000)

(SY3000)

4 A4 A
15

11

L2
4 x M5 hole Cut dimensions for panel mounting
One-touch fitting
4 x ø5.5 Refer to panel cut dimensions for
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8" details. S0700
One-touch fitting One-touch fitting
[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"Applicable tube O.D.: ø2
: ø6, ø1/4" : ø3.2, ø1/8"
: ø8, ø5/16" : ø4, ø5/32"
: ø6, ø1/4"
Note 1) These figures show the “SS5Y5-M11SQA-05D-C86”.
Note 2) Refer to page 11 for dimensions of D-sub communication connector,
external pilot and built-in silencer.

EX260 Serial transmission Calculation of dimensions


L1 = 12.5 x n1 + 16 x n2 + 88.7
L2 = 12.5 x n1 + 16 x n2 + 48

n1: SY3000 Valve stations


n2: SY5000 Valve stations

20
Plug-in Connector Connecting Base: Plug-in Mixed MountingType Manifold
For EX260 Integrated-type (For Output)
Serial Transmission System
Type 12
Top Ported
Series SY3000/5000 RoHS
SY3000 can be mounted onto SY5000 size manifold. How to Order Manifold

Refer to page 23 for Type 12/


Top ported dimensions. SS5Y5 M 12S NA N 05 U
Mixed Mounting Type q w e r t y u
It is possible to mount SY3000 size valves on all stations.
However, the manifold block width should be 12.5 mm. w SI unit output polarity
Nil Positive common
q SI unit specifications N Negative common
Symbol Protocol Number of outputs Communication connector Note 1) Ensure a match with the common specifications of the valve to be used.
0 Without SI unit Note 2) Without SI unit, the symbol is nil.
QA
QB
DeviceNet™
32
16
M12 e Valve stations
In the case of the 32-output SI unit In the case of the 16-output SI unit
NA 32
M12 Symbol Stations Note Symbol Stations Note
NB PROFIBUS 16
NC DP 32
02 2 stations 02 2 stations


D-sub Note) Double wiring Note 1) Double wiring Note 1)
ND 16
VA 32
16 16 stations 08 8 stations
CC-Link M12 02 2 stations 02 2 stations
VB 16 Specified layout Note 2) Specified layout Note 2)


DA 32 (Available up to 32 solenoids) (Available up to 16 solenoids)
EtherCAT M12 24 24 stations 16 16 stations
DB 16
FA 32 Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold
PROFINET M12 stations.
FB 16
Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a
EA 32 specified layout.
EtherNet/IP™ M12
EB 16 Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet.
Note) IP40 for the D-sub applicable communication (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been
connector specification. specified.)
For SI unit part number, refer to page 1. Note 3) Includes the number of blanking plate assemblies.
DIN rail and SI unit output polarity “N” cannot be Note 4) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be
selected for the product without SI unit. mounted. If the layout is specified, indicate it on the manifold specification sheet.

How to Order Manifold Assembly r P, E port entry


U Note) U side (2 to 10 stations)
D Note) D side (2 to 10 stations)
Example (SS5Y5-M12SNAN-l) B Both sides (2 to 24 stations)
2-position double Note) For type “S”, supply/exhaust block assembly with built-in silencer, choose U
2-position double
SY3230-5U1-C6(2 sets) or D for P port entry.
SY5230-5U1-C8 (3 sets)

Manifold base (5 stations) t SUP/EXH block assembly


SS5Y5-M12F1-05D Nil Internal pilot
S Internal pilot, Built-in silencer
R External pilot
∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is
plugged. The silencer exhaust port is located on the opposite side of P, E port entry.
(Example: When the P, E port entry is D side, the silencer exhaust port is U side.)
∗ When the built-in silencer type is used, keep the exhaust port from coming in direct
de
si

contact with water or other liquids.


U
s
on
ati

y P, E port size (One-touch fittings)


St
3
2

Nil ø10
1
de
si

N ø3/8"
D

∗ For N, sizes are in inches.


SS5Y5-M12F1-05D……1 set (Type M12 5-station manifold base part no.)
∗ SY5230-5U1-C8……….. 3 sets (2-position double part no.) u Mounting
∗ SY3230-5U1-C6……….. 2 sets (2-position double part no.) Nil Direct mounting
∗ The asterisk denotes the symbol for assembly. D DIN rail mounting (With DIN rail)
∗ Prefix it to the part nos. of the valve, etc. D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations Specify a longer rail than the standard length.
• The valve arrangement is numbered as the 1st station from the D side.

[The SY5000 valve is now at a mountable length


• Under the manifold part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. D24 For 24 stations (manifold block length of 16 mm).]
If the arrangement becomes complicated, specify on a manifold ∗ When it is necessary to mount a DIN rail without an SI unit, select D0 and order
specification sheet. DIN rail length separately, referring to L3 in the dimensions. Refer to the
SY3000/5000 series catalog (CAT.NAS11-103) for part numbers of DIN rail.

21
Plug-in Connector Connecting Base Series SY3000/5000

Refer to the SY3000/5000 series catalog


How to Order Valves (With two mounting screws) (CAT.NAS11-103) for details on valve specifications.

EX260
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 Nil Standard (101 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (101 psi (0.7 MPa)) Symbol Port size Applicable series
K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high pressure 01 1/8 SY5000

SY
type.
w Type of actuation One-touch fitting (Metric)
1 2-position single Symbol A and B port SY3000 SY5000
2 2-position double u Coil type C2 ø2 One-touch fitting P
3 3-position closed center Nil Standard C3 ø3.2 One-touch fitting P
4 3-position exhaust center T With power saving circuit (Continuous duty type) C4 ø4 One-touch fitting P P
5 3-position pressure center ∗ Be sure to select the power saving circuit type when a C6 ø6 One-touch fitting P P
A∗ 4-position dual 3-port valve (N.C./N.C.) valve is continuously energized for long periods of C8 ø8 One-touch fitting P
time.
B∗ 4-position dual 3-port valve (N.O./N.O.)
∗ Note the specified energizing time when power saving One-touch fitting (Inch)
C∗ 4-position dual 3-port valve (N.C./N.O.) circuit is selected. Symbol A and B port SY3000 SY5000
∗ Only rubber seal type is available for the 4-position N1 ø1/8" One-touch fitting P
dual 3-port valve. N3 ø5/32" One-touch fitting P P
i Rated voltage

SV
N7 ø1/4" One-touch fitting P P
5 24 VDC
N9 ø5/16" One-touch fitting P
e Seal type
0 Rubber seal
1 Metal seal
o Light/surge voltage suppressor !2 Thread type
and common specification
Nil Without light/surge voltage suppressor (Non-polar) Nil Rc
R With surge voltage suppressor (Non-polar) F G
r Pilot type U With light/surge voltage suppressor (Non-polar) N NPT
S With surge voltage suppressor (Positive common) T NPTF
Nil Internal pilot
R External pilot Z With light/surge voltage suppressor (Positive common) ∗ Only Nil is available for M5.

VQC
NS With surge voltage suppressor (Negative common)
NZ With light/surge voltage suppressor (Negative common)

t Back pressure check valve


∗ Only “Z” and “NZ” types are available for the product
with power saving circuit. Select a valve from R, U, S
!3 Type of mounting screw
(Built-in valve type) or Z when the SI unit output polarity is Nil (Positive Nil Round head combination screw
Nil None common). Select a valve from R, U, NS or NZ when B Hexagon socket head cap screw
H Built-in the SI unit output polarity is N (Negative common). Round head combination screw
K
(Falling-out-prevention type)
∗ Only rubber seal type.
Manifold installed type is available if the back pressure
Hexagon socket head cap screw
check valve is required for a valve with metal seal. Refer !0 Manual override H (Falling-out-prevention type)
to the SY3000/5000 series catalog (CAT.NAS11-103) Nil: D: ∗ For “K” and “H”, the valve body cover has a drop
for details. However, it is not recommended to use the prevention construction to stop the mounting screws
Non-locking Push-turn
S0700
built-in valve type and the manifold installed type at the from falling out when the valve is removed for
same time because it will reduce the flow. push type locking
slotted maintenance etc.
∗ The built-in valve type back pressure check valve is not ∗ When ordering a valve individually, the base gasket
available for the 3-position type. type
is not included. Since the base gasket is attached to
the manifold, please order the base gasket
separately if it is needed for maintenance service.
E: F: Refer to the SY3000/5000 series catalog
Push-turn Slide locking (CAT.NAS11-103) for part numbers of base gasket
locking type and mounting screw.
manual ∗ “B” and “H” cannot be selected for the individual
type SUP/EXH spacer assembly.

Refer to the SMC website or the SY3000/5000 series catalog (CAT.NAS11-103) for details
on solenoid valve specifications, Common Precautions and Specific Product Precautions.

22
Series SY3000/5000
Dimensions: Type 12/Mixed Mounting Type (mm)

U
SS5Y5-M12Smm- Stations DB(-D)

D side U side
(L5) L1
(Pitch of SY5000) Manual override
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"
45.1
Light/surge
21.1 P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
(Pitch of SY3000) 4(A) port side : Blue (For rubber seal)
78.9 voltage suppressor P = 12.5 : Gray (For metal seal)
DIN rail 8
(Slide locking manual override) 2(B) port side : Yellow

5.5
PE
3/5 B A B A B A B A B A
4A 4A
4A 4A 4A

35
(114.8)

97.5
113.4
26.5

E
101

X
1

81.2
(SY3000)
(SY3000)
2B 2B

(SY5000)

56.4
61.7

47.3

11
P

5.5
39.5

2B 2B 2B

10.9
(SY5000)
Cm: 14.5
01: 16.2
1.4

2.7
4.7

SI unit One-touch fitting


[4(A), 2(B) port]
Applicable tube O.D: ø4, ø5/32" 4 x M5 mounting hole
: ø6, ø1/4"
: ø8, ø5/16" One-touch fitting
34.2 L2 1.5 [4(A), 2(B) port]
Applicable tube O.D: ø2
5.3 L4 : ø3.2, ø1/8"
(DIN rail mounting hole pitch: 12.5) : ø4, ø5/32"
L3 : ø6, ø1/4"

(Station 1) (Station n) (Fitting for the type with P/E


(17.4) ports on U and/or D sides)
(SY5000)

(SY3000)

BUS OUT
(91.3)

(87.4)
76.7
(69.7)

1 P 1 P
BUS IN 2 B2 B2 B2 B2 B
56.6
8.7

3/5 E 4 A4 A4 A 3/5 E
PWR 4 A4 A
(For DIN rail
7.5

mounting)
11.8

Note 1) These figures show the “SS5Y5-M12SQA-05D”.


Note 2) Refer to page 16 for dimensions of D-sub communication connector,
external pilot and built-in silencer.

EX260 Serial transmission Calculation of dimensions


L1 = 12.5 x n1 + 16 x n2 + 88.7
L2 = 12.5 x n1 + 16 x n2 + 48
M = L1/12.5 + 1 Remove all numbers after the decimal.
L3 = 12.5 x M + 23
L4 = L3 − 10.5
L5 = (L3 − L1)/2
n1: SY3000 Valve stations
n2: SY5000 Valve stations

23
Tie-rod Base:
For EX260 Integrated-type (For Output)
Serial Transmission System ®

Series SV RoHS

How to Order Manifold

EX260
SS5V 1 W 10S1 NA N D 05 U
q Enclosure w e r t y u i
IP67
∗Refer to Note 1) of the w SI unit specifications.

q Series r Valve stations t P, E port entry


1 SV1000 In the case of the 32-output SI unit U U side (2 to 10 stations)
2 SV2000 Symbol Stations Note D D side (2 to 10 stations)
3 SV3000 02 2 stations B Both sides (2 to 20 stations)

SY
Double wiring Note 1)
w SI unit specifications 16 16 stations
Number of Communication 02 2 stations y SUP/EXH block assembly
Symbol Protocol Specified layout Note 2) Nil Internal pilot
outputs connector
(Available up to 32 solenoids)
0 Without SI unit 20 20 stations S Note) Internal pilot, Built-in silencer
QA 32 In the case of the 16-output SI unit
R External pilot
DeviceNet™ M12 RS Note) External pilot, Built-in silencer
QB 16 Symbol Stations Note
NA 32 02 2 stations Note) When the built-in silencer type is used, keep the
M12 exhaust port from coming in direct contact with
NB PROFIBUS 16 Double wiring Note 1) water or other liquids.
NC DP 32 08 8 stations
D-sub Note 1)
ND 16 02 2 stations
Specified layout Note 2)
VA 32 i Mounting

SV
CC-Link M12 (Available up to 16 solenoids)
VB 16 16 16 stations Nil Direct mounting
DA 32
Note 1) Double wiring: single, double, 3-position and D DIN rail mounting (With DIN rail)
EtherCAT M12
DB 16 4-position solenoid valves can be used on all D0 DIN rail mounting (Without DIN rail)
FA 32 manifold stations.
PROFINET M12 D3 For 3 stations When a longer DIN rail
FB 16 Use of a single solenoid will result in an
is desired than the
EA 32 unused control signal. If this is not desired,
EtherNet/IP™ M12 specified stations.
order with a specified layout.
EB 16 (Specify a longer rail
Note 2) Specified layout: Indicate the wiring
I DIN rail cannot be selected for the product specifications on the manifold specification D20 For 20 stations
than the standard
without SI unit. length.)
sheet.
Note 1) IP40 for the D-sub applicable (Note that double, 3-position and 4- position
communication connector specification. valves cannot be used where single solenoid

VQC
(The manifold part number is “SS5Vl- wiring has been specified.)
10S1NC/NDlD”.) Note 3) Includes the number of blanking plate
Note 2) For SI unit part number, refer to page 1. assemblies.

e SI unit output polarity


Nil Positive common
N Negative common
Note) Without SI unit, the symbol is nil.

u A, B port size (Metric) A, B port size (Inch)


Symbol A, B port P, E port Applicable series Symbol A, B port P, E port Applicable series
S0700
C3 ø3.2 One-touch fitting N1 ø1/8" One-touch fitting
ø8 ø5/16"
C4 ø4 One-touch fitting SV1000 N3 ø5/32" One-touch fitting SV1000
One-touch fitting One-touch fitting
C6 ø6 One-touch fitting N7 ø1/4" One-touch fitting
C4 ø4 One-touch fitting N3 ø5/32" One-touch fitting
ø10 ø3/8"
C6 ø6 One-touch fitting SV2000 N7 ø1/4" One-touch fitting SV2000
One-touch fitting One-touch fitting
C8 ø8 One-touch fitting N9 ø5/16" One-touch fitting
C6 ø6 One-touch fitting N7 ø1/4" One-touch fitting
ø12 ø3/8"
C8 ø8 One-touch fitting SV3000 N9 ø5/16" One-touch fitting SV3000
One-touch fitting One-touch fitting
C10 ø10 One-touch fitting N11 ø3/8" One-touch fitting
M A, B ports mixed M A, B ports mixed
∗ In the case of mixed specifications (M), indicate separately on the manifold specification sheet.
∗ The X and PE port size of External pilot type (R, RS) are ø4 (mm) or ø5/32" (inch) for the SV1000/2000 series, and ø6 (mm) or ø1/4" (inch) for the SV3000 series.

24
Series SV
How to Order Manifold Assembly

Example (SV1000)
Double solenoid
Manifold SV1200-5FU (2 sets)
SS5V1-W10S1NAND-04B-C6 (1 set) Single solenoid
SV1100-5FU (2 sets)

Us
ide
SS5V1-W10S1NAND-04B-C6·····1 set (Manifold part no.)
∗SV1100-5FU································2 sets (Single solenoid part no.)
∗SV1200-5FU································2 sets (Double solenoid part no.)

D
S
ta

D
tio
ns

D
3 D
2 Ds
1 ide

How to Order Valves

SV 1 1 0 0 5F
Note)

q w e r t y u i
q Series r Back pressure check valve Note) Available with manifold block for station
additions. Refer to Best Pneumatics No. 1.
1 SV1000 Nil None
2 SV2000 K Built-in
3 SV3000 ∗ Built-in back pressure check valve type is i Made to Order
applicable to the SV1000 series only. Nil —
∗ Back pressure check valve is not available for
w Type of actuation 3-position valve. X90
Main valve fluororubber
(Refer to page 448 in Best Pneumatics No. 1.)
1 2-position single Note) Refer to Specific Product Precautions 2
2 2-position double in Best Pneumatics No. 1.
3 3-position closed center t Rated voltage
4 3-position exhaust center 5 24 VDC
5 3-position pressure center
A 4-position dual 3-port valve: N.C./N.C.
B 4-position dual 3-port valve: N.O./N.O. y Light/surge voltage suppressor
C 4-position dual 3-port valve: N.C./N.O. U With light/surge voltage suppressor
∗ 4-position dual 3-port valves are applicable to R With surge voltage suppressor
the SV1000/2000 series only.

u Manual override
e Pilot type Nil: Non-locking push type D: Push-turn locking slotted type
Nil Internal pilot
R External pilot
∗ External pilot specification is not available for
4-position dual 3-port valves.

Refer to the SMC website or the SV series in Best Pneumatics No.1 for details on solenoid valve
specifications, Common Precautions and Specific Product Precautions.

25
Tie-rod Base:
For EX260 Integrated-type (For Output) Serial Transmission System Series SV
Dimensions: For EX260 Integrated-type (For Output) Serial Transmission System/Series SV1000
U C3, N1 (mm)
P Tie-rod base manifold: SS5V1-W10S1llD - Stations D
B
(S, R, RS)- C4, N3
C6, N7
(-D)
• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
• External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.

D side (L1) U side

EX260
(5) (L2)
(DIN rail mounting hole pitch: 12.5)

Manual override Light/surge voltage suppressor


Press and turn for SOL.a: Orange
SOL.b: Green 4 x ø5.3
the locking type.
4(A) port side: Orange (For mounting)
Manual portion

1.9
2(B) port side: Green

4.6
(5.5)

29.6
(39.6)
40.4
A

A
(35)
90.9

92.6
102.4

83

SY
A A A A

(8)
B B B B
(DIN rail)

3-NC
3-NC
(4.9)

(C6: 3.2)
DIN rail holding screw

(N7: 7)
SI unit (For DIN rail mounting)

Silencer (exhaust port) 33.7 L5


(Built-in silencer specification) (L4) L3

SV
(Station 1) (Station n)
One-touch fitting (42.3) (8.4) One-touch fitting
[X: External pilot port] [PE: Pilot EXH port]
[Communication connector D-sub] Applicable tube O.D. C4: ø4 (SMC) Applicable tube O.D. C4: ø4 (SMC)
N3: ø5/32" (SMC) N3: ø5/32" (SMC)
(External pilot specification)

BUS BUS OUT


76.7

76.7

VQC
BUS IN
(56.5)

58.7
8.6
9.2
P 1 P 1 P 1
2 B 2 B 2 B 2 B2 B 2 B 2 B

45.5
44.7
(43)

PWR PWR

24.6
E 3/5 E 3/5 E 3/5 22.2
10

4 A4 4 A4 A4 A4 A4 A

46.5 (Pitch)
(7.5)

(11.8)

One-touch fitting 46.5 13.5 P = 10.5


[1(P), 3/5(E) port]
Applicable tube O.D. C8: ø8 (SMC) One-touch fitting
N9: ø5/16" (SMC) [4(A), 2(B) port]
Applicable tube O.D. C3: ø3.2 (SMC)
S0700
C4: ø4 (SMC)
C6: ø6 (SMC)
N1: ø1/8" (SMC)
N3: ø5/32" (SMC)
N7: ø1/4" (SMC)

L: DIN Rail Overall Length n: Stations


n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L
L1 135.5 148 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323
L2 125 137.5 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5
L3 102.2 112.7 123.2 133.7 144.2 154.7 165.2 175.7 186.2 196.7 207.2 217.7 228.2 238.7 249.2 259.7 270.2 280.7 291.2
L4 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16 17 12 13 14 15 16
L5 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252

26
Series SV
Dimensions: For EX260 Integrated-type (For Output) Serial Transmission System/Series SV2000
(mm)
U C4, N3
P Tie-rod base manifold: SS5V2-W10S1llD - Stations D
B
(S, R, RS)- C6, N7
C8, N9
(-D)
• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
• External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.

D side (L1) U side


(5) (L2)
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
Manual override Light/surge voltage suppressor (For DIN rail mounting)
Press and turn for SOL.a: Orange
the locking type. SOL.b: Green
4(A) port side: Orange
Manual portion

5.9

5.4
2(B) port side: Green

29.6
41.8
(53.4)
(5.5)

A
B

B
90.9

109.4
(35)

97.5
A A A A
102.4

115.5
(8) (DIN rail)
B B B B

3-NC
3-NC
SI unit
(4.9)
(5.3)

4 x ø5.3
Silencer (exhaust port) 34.4 L5 (For mounting)
(Built-in silencer specification) (L4) L3

(Station 1) (Station n)
One-touch fitting
One-touch fitting [PE: Pilot EXH port]
[X: External pilot port] Applicable tube O.D. C4: ø4 (SMC)
Applicable tube O.D. C4: ø4 (SMC) (43.9) (9.5) N3: ø5/32" (SMC)
N3: ø5/32" (SMC) One-touch fitting
[Communication connector D-sub] [1(P), 3/5(E) port]
Applicable tube O.D. C10: ø10 (SMC)
N11: ø3/8" (SMC)
(External pilot specification)

BUS BUS OUT


11.9
76.7
76.7

P 1 P 1 P 1
9.2
(63.5)

BUS IN 63.5
B 2 B 2 B 2 B 2 B 2 B 2 B 2
(49.9)

52.5

E 3/5 E 3/5 E 3/5


30.6

PWR PWR
25.2

A 4 A A 4 A 4 A 4 A 4 A 4
12

(Pitch)
(7.5)

48.7
(11.8)

48.7 17.5 P = 16
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. C4: ø4 (SMC)
C6: ø6 (SMC)
C8: ø8 (SMC)
N3: ø5/32" (SMC)
N7: ø1/4" (SMC)
N9: ø5/16" (SMC)
L: DIN Rail Overall Length n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L
L1 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5
L2 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 325 350 362.5 375 400 412.5 425
L3 120.2 136.2 152.2 168.2 184.2 200.2 216.2 232.2 248.2 264.2 280.2 296.2 312.2 328.2 344.2 360.2 376.2 392.2 408.2
L4 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5
L5 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368

27
Tie-rod Base:
For EX260 Integrated-type (For Output) Serial Transmission System Series SV
Dimensions: For EX260 Integrated-type (For Output) Serial Transmission System/Series SV3000
U C6, N7 (mm)
P Tie-rod base manifold: SS5V3-W10S1llD - Stations DB (S, R, RS)- C8, N9
C10, N11
(-D)
• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
• External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.

D side (L1) U side


(5) (L2)

EX260
(DIN rail mounting hole pitch: 12.5)
Manual override
Light/surge voltage suppressor Press and turn for
SOL.a: Orange the locking type.
SOL.b: Green 4(A) port side: Orange
4 x ø5.3 2(B) port side: Green
5.4

(For mounting) Manual portion

5
29.6
(5.5)

(46.9)
43.9
A

83.8
(35)

104.1
90.9

SY
102.4

A A A A

128.8
(8) (DIN rail)

B B B B

SI unit

DIN rail holding screw


Silencer (exhaust port)
(5.1)

(5.3)

(For DIN rail mounting)


(Built-in silencer specification)
36.2 L5

SV
(L4) L3

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[X: External pilot port] (47.7) (11) Applicable tube O.D. C6: ø6 (SMC)
Applicable tube O.D. C6: ø6 (SMC) One-touch fitting C8: ø8 (SMC)
N7: ø1/4" (SMC) [PE: Pilot EXH port] C10: ø10 (SMC)
Applicable tube O.D. C6: ø6 (SMC) N7: ø1/4" (SMC)
N7: ø1/4" (SMC) N9: ø5/16" (SMC)
[Communication connector D-sub] N11: ø3/8" (SMC)

VQC
(External pilot specification)

BUS BUS OUT


P 1 P 1 P 1
B 2 B 2 B 2 B 2 B 2 B 2 B 2 82.7
(76.8)
76.7

76.7

63.8
(60.3)

BUS IN
11.6
13.5

37.6
36.1

E 3/5 A 4 A E 3/5 A 4 A 4 A 4 A 4 A 4 E 3/5


PWR PWR
12

53.2
(10)

(Pitch)
(14.7)

S0700
53.2 21.2 P = 20.5

One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D. C12: ø12 (SMC)
N11: ø3/8" (SMC)

L: DIN Rail Overall Length n: Stations


n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L
L1 173 185.5 210.5 235.5 248 273 298 310.5 335.5 348 373 398 410.5 435.5 460.5 473 498 523 535.5
L2 162.5 175 200 225 237.5 262.5 287.5 300 325 337.5 362.5 387.5 400 425 450 462.5 487.5 512.5 525
L3 139.7 160.2 180.7 201.2 221.7 242.2 262.7 283.2 303.7 324.2 344.7 365.2 385.7 406.2 426.7 447.2 467.7 488.2 508.7
L4 16.5 12.5 15 17 13 15.5 17.5 13.5 16 12 14 16.5 12.5 14.5 17 13 15 17.5 13.5
L5 97 117.5 138 158.5 179 199.5 220 240.5 261 281.5 302 322.5 343 363.5 384 404.5 425 445.5 466

28
Plug-in Unit:
For EX260 Integrated-type (For Output)
Serial Transmission System
Base
Mounted
Series VQC1000 RoHS

How to Order Manifold

VV5QC 1 1 08 C6 SNA N B …… S Kit


qw e r t y u
q Series r Cylinder port size y SI unit output polarity
1 VQC1000 C3 With ø3.2 One-touch fitting Nil Positive common
C4 With ø4 One-touch fitting N Negative common
w Manifold model C6 With ø6 One-touch fitting
1 Plug-in unit M5 M5 thread u Option
CM Mixed sizes and with port plug Nil None
e Stations L3
Top ported elbow
with ø3.2 One-touch fitting
B With back pressure check valve (All stations) Note 2)
In the case of the 32-output SI unit D With DIN rail (Rail length: Standard)
Top ported elbow Dl With DIN rail (Rail length: Special) Note 3)
Symbol Stations Note L4 with ø4 One-touch fitting
02 2 stations K Special wiring spec. (Except double wiring) Note 4)
Top ported elbow N With name plate

L6

Double wiring Note 1) with ø6 One-touch fitting


12 12 stations R External pilot Note 5)
L5 M5 thread S Built-in silencer, Direct exhaust Note 6)
02 2 stations
Specified layout Note 2) Bottom ported elbow

B3

Note 1) When two or more symbols are specified, indicate


(Available up to 24 solenoids) with ø3.2 One-touch fitting them alphabetically.
24 24 stations
Bottom ported elbow Example: -BRS
In the case of the 16-output SI unit B4 with ø4 One-touch fitting Note 2) When the back pressure check valve is desired,
Symbol Stations Note Bottom ported elbow and is to be installed only in certain manifold
02 2 stations B6 with ø6 One-touch fitting stations, specify the mounting position on the
manifold specification sheet.

Double wiring Note 1) B5 M5 thread Note 3) For special DIN rail length, indicate “Dl”.
08 8 stations LM Elbow port, mixed sizes (Enter the number of stations inside l.)
02 2 stations MM Note2) Mixed size for different types of piping, option installed Example: -D08
Specified layout Note 2)

Note 1) Indicate the sizes on the manifold specification sheet in In this case, stations will be mounted on a DIN rail
(Available up to 16 solenoids)
16 16 stations the case of “CM”, “LM”. for 8 stations regardless of the actual number of
Note 2) When selecting the mixed size for different types of manifold stations.
Note 1) Double wiring: single, double, 3-position and
piping or dual flow fitting assembly, enter “MM” and The specified number of stations must be larger
4-position solenoid valves can be used on all
give instructions in the manifold specification sheet. than the number of stations on the manifold.
manifold stations.
Note 3) Symbols for inch sizes are as follows: Indicate “-D0” for the option without DIN rail.
Use of a single solenoid will result in an unused
• N1: ø1/8" Note 4) Specify wiring type of each station on the manifold
control signal. If this is not desired, order with a
• N3: ø5/32" specification sheet.
specified layout.
• N7: ø1/4" Note 5) For external pilot option, “-R”, indicate the external
Note 2) Specified layout: Indicate the wiring specifications
• NM: Mixed pilot specification “R” for the applicable valves as
on the manifold specification sheet.
The top ported elbow is LNl and the bottom ported well.
(Note that 2-position double, 3-position and
elbow is BNl. Note 6) Built-in silencer type does not satisfy IP67.
4-position valves cannot be used where single
wiring has been specified.) Note 7) When the “SD0” (Without SI unit) is specified, “-D”,
Note 3) Includes the number of blanking plate assemblies. “-Dl” cannot be selected.

t Kit type
Number of Communication
Symbol Protocol outputs connector
S Kit
(Serial transmission kit (for Output))
SD0
SQA
DeviceNet™
Without SI unit
32
M12
SI unit SQB 16
SNA 32
M12
SNB 16
PROFIBUS DP
SNC 32
D-sub Note 1)
SND 16
SVA 32
CC-Link M12
SVB 16
SDA 32
EtherCAT M12 Note 1) D-sub S kit: IP40
SDB 16 specification (IP67
SFA 32 specification for all other
PROFINET M12
IP40 specification
SFB 16 S kits)
SEA 32 Note 2) For SI unit part number,
EtherNet/IP™ M12 refer to page 1.
SI unit: EX260 IP67 specification SEB 16

29
Plug-in Unit:
For EX260 Integrated-type (For Output) Serial Transmission System Series VQC1000
How to Order Valves

VQC 1 1 0 0 5 1
Series VQC1000 q w e r t y
q Type of actuation w Seal type y Manual override

EX260
2-position single 0 Metal seal Nil: Non-locking push type
(A)4 2(B) 1 Rubber seal (Tool required)
1
e Function

B
(R1) 5 1 3 (R2)

A
(P)
Nil Standard (0.4 W)
Quick response type
2-position double (Metal) B (0.95 W)
(A)4 2(B) High pressure type
K Note 2) (145 psi (1.0 MPa), 0.95 W) B: Locking type
(R1) 5 1 3 (R2) N Note 3) Negative common (Tool required)
(P) R Note 4) External pilot
2
2-position double (Rubber) Note 1) When two or more symbols

SY
A
(A)4 2(B) are specified, indicate them
alphabetically. However,
combination of “B” and “K” is
(R1) 5 1 3 (R2) not possible.
(P)
Note 2) Only metal seal type C: Locking type
3-position closed center Note 3) When negative common is (Manual)
(A)4 2(B) specified for SI unit, select and
3 mount the valve of negative
common.

B
A
(R1) 5 1 3 (R2) Note 4) Not applicable for dual 3-port
(P)
valves
3-position exhaust center
(A)4 2(B) r Coil voltage

SV
D: Slide locking type
4 5 24 VDC (Manual)
(R1) 5 1 3 (R2)
(P)
t Light/surge voltage
3-position pressure center suppressor
(A)4 2(B)
Nil Yes
5
(R1) 5 1 3 (R2)
(P)

4-position dual 3-port valve (A)


(A)4 2(B)

VQC
A Note)

5(R1) 1(P) 3(R2)

4-position dual 3-port valve (B)


(A)4 2(B)

B Note)
S0700
5(R1) 1(P) 3(R2)

4-position dual 3-port valve (C)


(A)4 2(B)

C Note)

5(R1) 1(P) 3(R2)

Note) Only rubber seal type

Refer to the SMC website or the VQC1000/2000 series catalog (CAT.NAS11-101) for details
on solenoid valve specifications, Common Precautions and Specific Product Precautions.

30
Series VQC1000
S Kit (Serial transmission) For EX260 Integrated-type (For Output) Serial Transmission System
(mm)
VV5QC11
S Kit (Serial transmission kit: EX260)

L2
42.5 L1
P = 10.5 28 4 x M4 mounting hole
Indicator light
1.5 1.5

(5.5)
(35)
(DIN rail)
(12) 63.5

2
(8)
A A B A B A B A B A

93.5
(118.9)

66
75
90.9
102.4

(40)
Manual portion
(2)
(L3) (5.25)
SI unit
(DIN rail mounting hole pitch: 12.5)
(L4)

Manual override
(Press and turn for the locking type.)
D side Stations 1 2 3 4 5 6 7 n U side

[Communication connector D-sub] (DIN rail clamping screw)

BUS BUS OUT


R R R
76.7

76.7

62.5
58.7
3 BUS IN 3 3
X X X
12 B 12 B B B B B B B12 40.5
PWR PWR
P P P
25

1A A 1A A A A A A A 1
18.5
9.5
7.5
13

56.9 20.5
(7.5)

One-touch fitting
56.9 13.4
[1(P), 3(R) port]
Applicable tube O.D. C8: ø8 (SMC)
N9: ø5/16" (SMC)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. C3: ø3.2 (SMC)
C4: ø4 (SMC)
C6: ø6 (SMC)
N1: ø1/8" (SMC)
N3: ø5/32" (SMC)
N7: ø1/4" (SMC)
M5: M5 thread

n: Stations (Maximum 24 stations)


L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150 160.5 171 181.5 192 202.5 213 223.5 234 244.5 255 265.5 276 286.5 297
L2 104.2 114.7 125.2 135.7 146.2 156.7 167.2 177.7 188.2 198.7 209.2 219.7 230.2 240.7 251.2 261.7 272.2 282.7 293.2 303.7 314.2 324.7 335.2 345.7
L3 127 139.5 152 164.5 177 177 189.5 202 214.5 227 239.5 239.5 252 264.5 277 289.5 302 314.5 314.5 327 339.5 352 364.5 377
L4 137.5 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5 375 387.5

31
Plug-in Unit:
For EX260 Integrated-type (For Output)
Base
Mounted Serial Transmission System

Series VQC2000 RoHS

How to Order Manifold

EX260
VV5QC 2 1 08 C6 SNA N B S Kit
qw e r t y u
q Series r Cylinder port size u Option
2 VQC2000 C4 ø4 One-touch fitting Nil None
C6 ø6 One-touch fitting B With back pressure check valve (All stations) Note 2)
w Manifold model C8 ø8 One-touch fitting D With DIN rail (Rail length: Standard)
1 Plug-in unit CM Mixed sizes and with port plug Dl With DIN rail (Rail length: Special) Note 3)
Top ported elbow K Special wiring spec. (Except double wiring) Note 4)
e Stations L4
with ø4 One-touch fitting N With name plate

SY
In the case of the 32-output SI unit Top ported elbow R External pilot Note 5)
L6
Symbol Stations Note with ø6 One-touch fitting S Built-in silencer, Direct exhaust Note 6)
02 2 stations Top ported elbow T P and R ports included on both sides of the U side Note 7)
L8
Double wiring Note 1) with ø8 One-touch fitting Note 1) When two or more symbols are specified,
12 12 stations Bottom ported elbow indicate them alphabetically.
B4
02 2 stations with ø4 One-touch fitting Example: -BRS
Specified layout Note 2) Note 2) When the back pressure check valve is desired,
Bottom ported elbow
(Available up to 24 solenoids) B6 and is to be installed only in certain manifold
24 24 stations with ø6 One-touch fitting
Bottom ported elbow stations, specify the mounting position on the
In the case of the 16-output SI unit B8 manifold specification sheet.
with ø8 One-touch fitting
Symbol Stations Note Note 3) For special DIN rail length, indicate “Dl”.
02 2 stations LM Elbow port, mixed sizes
(Enter the number of stations inside l.)

SV
Double wiring Note 1) Mixed size for different types of piping, Example: -D08
MM Note 2) option installed
08 8 stations In this case, stations will be mounted on a DIN
02 2 stations Note 1) Indicate the sizes on the manifold rail for 8 stations regardless of the actual
Specified layout Note 2) specification sheet in the case of “CM”, number of manifold stations.
(Available up to 16 solenoids) “LM”. The specified number of stations must be larger
16 16 stations
Note 2) When selecting the mixed size for different than the number of stations on the manifold.
Note 1) Double wiring: single, double, 3-position Indicate “-D0” for the option without DIN rail.
types of piping or dual flow fitting assembly,
and 4-position solenoid valves can be Note 4) Specify wiring type of each station on the
enter “MM” and give instructions in the
used on all manifold stations. manifold specification sheet.
manifold specification sheet.
Use of a single solenoid will result in an Note 5) For external pilot option, “-R”, indicate the
Note 3) Symbols for inch sizes are as follows:
unused control signal. If this is not desired, external pilot specification “R” for the applicable
• N3: ø5/32"
order with a specified layout. valves as well.
• N7: ø1/4"
Note 2) Specified layout: Indicate the wiring

VQC
• N9: ø5/16" Note 6) Built-in silencer type does not satisfy IP67.
specifications on the manifold specification Note 7) 2 ports for SUP and EXH are included on both
• NM: Mixed
sheet. sides of U side (cylinder port and coil side) with
The top ported elbow is LNl and the bottom
(Note that 2-position double, 3-position ø12 One-touch fittings.
ported elbow is BNl.
and 4-position valves cannot be used Note 8) When the “SD0” (Without SI unit) is specified,
where single wiring has been specified.) y SI unit output polarity “-D”, “-Dl” cannot be selected.
Note 3) Includes the number of blanking plate Nil Positive common
assemblies. N Negative common
t Kit type
Number Communication
Symbol Protocol
S Kit
(Serial transmission kit (for Output)) SD0
SQA
of outputs
Without SI unit
32
connector S0700
DeviceNet™ M12
SQB 16
SNA 32
M12
SI unit SNB 16
PROFIBUS DP
SNC 32
D-sub Note 1)
SND 16
SVA 32
CC-Link M12
SVB 16
Note 1) D-sub S kit: IP40
SDA 32 specification (IP67
EtherCAT M12
SDB 16 specification for all
SFA 32 other S kits)
PROFINET M12
SFB 16 Note 2) For SI unit part
IP40 specification SEA 32 number, refer to
EtherNet/IP™ M12 page 1.
SI unit: EX260 IP67 specification
SEB 16

32
Series VQC2000
How to Order Valves

VQC 2 1 0 0 5 1
Series VQC2000 q w e r t y
q Type of actuation w Seal type y Manual override
2-position single 0 Metal seal Nil: Non-locking push type
(A)4 2(B) 1 Rubber seal (Tool required)
1
e Function
(R1)5 1 3(R2) Nil Standard (0.4 W)
(P)
Quick response type
2-position double (Metal) B (0.95 W)
(A)4 2(B) High pressure type
K Note 2)
(145 psi (1.0 MPa), 0.95 W) B: Locking type
N Note 3) Negative common (Tool required)
(R1)5 1 3(R2)
(P) R Note 4) External pilot
2 Note 1) When two or more symbols are
2-position double (Rubber)
(A)4 2(B) specified, indicate them
alphabetically. However,
combination of “B” and “K” is
(R1)5 1 3(R2) not possible.
(P) Note 2) Only metal seal type C: Locking type
3-position closed center Note 3) When negative common is
(Manual)
(A)4 2(B) specified for SI unit, select and
mount the valve of negative
3 common.
(R1)5 1 3(R2) Note 4) Not applicable for dual 3-port
(P) valves
3-position exhaust center
(A)4 2(B)
r Coil voltage
5 24 VDC D: Slide locking type
4 (Manual)
(R1)5 1 3(R2)
(P) t Light/surge voltage
3-position pressure center suppressor
(A)4 2(B) Nil Yes
5
(R1)5 1 3(R2)
(P)

4-position dual 3-port valve (A)


4(A) 2(B)

A Note)

5(R1) 1(P) 3(R2)

4-position dual 3-port valve (B)


4(A) 2(B)

B Note)

5(R1) 1(P) 3(R2)

4-position dual 3-port valve (C)


4(A) 2(B)

C Note)

5(R1) 1(P) 3(R2)

Note) Only rubber seal type

Refer to the SMC website or the VQC1000/2000 series catalog (CAT.NAS11-101) for details
on solenoid valve specifications, Common Precautions and Specific Product Precautions.

33
Series VQC2000
S Kit (Serial transmission) For EX260 Integrated-type (For Output) Serial Transmission System
(mm)
VV5QC21
S Kit (Serial transmission kit: EX260)
L2
38.5 L1
Indicator light

EX260
P = 16 38.5
1 0.9 1

(10.5)
(In case of double sided type)
(12) 74 (DIN rail) 4 x M5 mounting hole

1.3
(8)
(127.2)

120
105.5
90.9

91.7
80
102.4

(53.5)
(35)
(5.5)

SY
SI unit
(3.5)

(5.5)
Manual portion

Manual override
(Press and turn for the locking type.)

(L3) (5.25)
(DIN rail mounting hole pitch: 12.5)
(L4)

D side Stations 1 2 3 4 5 6 7 n U side

SV
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D. C10: ø10 (SMC)
[Communication connector D-sub] N11: ø3/8" (SMC)
(DIN rail clamping screw)
(C12: ø12 (SMC) (In case of double sided type))

R R R
BUS BUS OUT
76.7

76.7

76.5
3 3 3

72
12 BUS IN 12
X

VQC
X
B
X
B B B B B B B 49.5
P P 12
P
30

PWR PWR
25

1 1
A A A A A A A A A 1
13.5
13

55 25
(7.5)

55 18 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. C4: ø4 (SMC)
C6: ø6 (SMC)
C8: ø8 (SMC)
N3: ø5/32" (SMC)
N7: ø1/4" (SMC)
S0700
N9: ø5/16" (SMC)

n: Stations (Maximum 24 stations)


L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 73 89 105 121 137 153 169 185 201 217 233 249 265 281 297 313 329 345 361 377 393 409 425 441
L2 118 134 150 166 182 198 214 230 246 262 278 294 310 326 342 358 374 390 406 422 438 454 470 486
L3 139.5 164.5 177 189.5 202 227 239.5 252 277 289.5 302 314.5 339.5 352 364.5 389.5 402 414.5 427 452 464.5 477 489.5 514.5
L4 150 175 187.5 200 212.5 237.5 250 262.5 287.5 300 312.5 325 350 362.5 375 400 412.5 425 437.5 462.5 475 487.5 500 525

34
Plug-in Unit:
For EX260 Integrated-type (For Output)
Serial Transmission System
Base
Mounted
Series VQC4000 RoHS

How to Order Manifold

VV5QC 4 1 16 03 SNA N S Kit


qw e r t y u i
q Series e Stations u SI unit output polarity
4 VQC4000 In the case of the 32-output SI unit Nil Positive common
Symbol Stations Note N Negative common
w Manifold model 01 1 station

1 Plug-in unit
12 12 stations
Double wiring Note 1)
i Option
Nil None
01 1 station
r Cylinder port size Specified layout Note 2)
(Available up to 24 solenoids)
S
K
Built-in silencer, Direct exhaust Note 1)
Special wiring spec. (Except double wiring) Note 2)
C8 With ø8 One-touch fitting 16 16 stations
Note 1) Built-in silencer type does not satisfy IP67.
C10 With ø10 One-touch fitting In the case of the 16-output SI unit Note 2) Specify wiring type of each station on the manifold
C12 With ø12 One-touch fitting Symbol Stations Note specification sheet.
02 Rc1/4 01 1 station
03 Rc3/8 Double wiring Note 1)
B Bottom ported Rc1/4 08 8 stations
CM Mixed 01 1 station
Note 1) Indicate the sizes on the manifold Specified layout Note 2)
specification sheet in the case of “CM”. (Available up to 16 solenoids)
16 16 stations
Note 2) Symbols for inch sizes are as follows: Note 1) Double wiring: single, double, 3-position and
<In the case of One-touch fittings> 4-position solenoid valves can be used on all
• N7: ø1/4" manifold stations.
• N9: ø5/16" Use of a single solenoid will result in an unused
• N11: ø3/8" control signal. If this is not desired, order with a
• NM: Mixed specified layout.
Note 2) Specified layout: Indicate the wiring
t Thread type specifications on the manifold specification
Nil Rc sheet.
F G (Note that 2-position double, 3-position and
4-position valves cannot be used where single
T NPT/NPTF
wiring has been specified.)
Note 3) Includes the number of blanking plate
y Kit type assemblies.

Protocol Number of Communication


Symbol outputs connector

S Kit
(Serial transmission kit (for Output))
SD0A
SQA
DeviceNet™
Without SI unit
32
M12
SQB 16
SNA 32
M12
SNB 16
PROFIBUS DP
SNC 32
D-sub Note 1)
SND 16
SVA 32
CC-Link M12
SVB 16
SDA 32
EtherCAT M12
SI unit SDB 16
SFA 32
PROFINET M12
SFB 16
SEA 32
EtherNet/IP™ M12
SEB 16
Note 1) D-sub S kit: IP40 specification (IP67 specification for all
other S kits)
Note 2) For SI unit part number, refer to page 1.
IP40 specification
SI unit: EX260 IP67 specification

35
Plug-in Unit:
For EX260 Integrated-type (For Output) Serial Transmission System Series VQC4000

How to Order Valves

VQC 4 1 0 0 5

EX260
Series VQC4000 q w e r t y
q Type of actuation w Seal type y Manual override
2-position single 0 Metal seal Nil: Non-locking push type
(A) 4 2(B) 1 Rubber seal (Tool required)
1
(R1) 5 1 3(R2)
(P)
e Function
Nil Standard (1 W)
2-position double (Metal) R External pilot
(A) 4 2(B)
Y Note 2) Low wattage type (0.5 W)
Note 1) When two or more

SY
(R1) 5 1 3(R2) symbols are specified,
(P) indicate them alphabeti-
2 cally.
2-position double (Rubber)
(A) 4 2(B) Note 2) Select “Y” when a valve is B: Locking type
continuously energized (Tool required)
for long periods of time.
(R1) 5 1 3(R2)
(P)

3-position closed center r Coil voltage


(A) 4 2(B) 5 24 VDC
3
(R1) 5 1 3(R2) t Light/surge voltage

SV
(P)
suppressor
3-position exhaust center Nil Yes
(A) 4 2(B)
Without light, with surge
4 E
voltage suppressor
(R1) 5 1 3(R2)
(P)

3-position pressure center


(A) 4 2(B)
5
(R1) 5 1 3(R2)
(P)

VQC
3-position double check
(A) 4 2(B)
6
(R1) 5 1 3(R2)
(P)

Refer to the SMC website or the VQC4000 series in Best Pneumatics No.1 for details on solenoid
S0700
valve specifications, Common Precautions and Specific Product Precautions.

36
VQC4000
S Kit (Serial transmission) For EX260 Integrated-type (For Output) Serial Transmission System
(mm)
VV5QC41
S Kit (Serial transmission kit: EX260)
L2
39.5 L1 (6.5)
(n−1) x 25
Indicator light
25 65.5
Manual override

9
A A B A B A B A B A B A

A A A A A A A

143
163
B B

9
B B B
SI unit

10
D side Stations 1 2 3 4 5 6 7 8 n U side

2 x Rc3/4
3 (R) port
[Communication connector D-sub] 2 x Rc1/2
1 (P) port

SMC SMC SMC SMC SMC SMC SMC SMC

101
95.5
77.5
76.7

76.7
15.7

15.7

43.5
42.7

42.7

20.5
12
11.5

2 x Rc1/8 2 x Rc1/8
External pilot port Pilot EXH port
21.5 (6.5)
27
2n x Rc1/4, 3/8, C8, C10, C12 31
4 (A), 2 (B) port 38.7
25 65.5

n: Stations (Maximum 16 stations)


L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 131 156 181 206 231 256 281 306 331 356 381 406 431 456 481 506
L2 177 202 227 252 277 302 327 352 377 402 427 452 477 502 527 552

37
Plug-in Manifold Stacking Base S Kit (Serial Transmission):
For EX260 Integrated-type (For Output)
Serial Transmission System

Series S0700 RoHS

How to Order Manifold

EX260
SS0750 08 C4 C8 SNA N B
q w e r t y
q Stations e P, R port size y Option
In the case of the 32-output SI unit Symbol Port size Symbol Option
Symbol Stations Note Nil With ø8 One-touch fitting Note) Nil None
01 1 station C6 With ø6 One-touch fitting Metric B Note 2) With back pressure check valve (All stations)
Double wiring Note 1) C8 With ø8 One-touch fitting D With DIN rail (Rail length: Standard)

SY
16 16 stations N7 With ø1/4" One-touch fitting D0 Without DIN rail (With bracket)
Inch
01 1 station N9 With ø5/16" One-touch fitting Dl Note 3) With DIN rail (Rail length specified, l: Stations)
Specified layout Note 2) Special wiring specifications
Note) The cylinder port is ø5/16" when measured in
(Available up to 32 solenoids) K Note 4) (Except double wiring)
24 24 stations inches.
N With name plate
In the case of the 16-output SI unit
Symbol Stations Note r Kit type R Note 5) External pilot
Number of Communication S Built-in silencer
01 1 station Symbol Protocol
outputs connector Note 1) When two or more options are specified, indicate
Double wiring Note 1)
08 8 stations SD0 Without SI unit them alphabetically.
01 1 station SQA 32 Example) -BKN
DeviceNet™ M12
Specified layout Note 2) SQB 16 Note 2) When the back pressure check valve is desired,
(Available up to 16 solenoids) SNA 32 and is to be installed only in certain manifold

SV
16 16 stations M12 stations, specify the mounting position on the
SNB PROFIBUS 16
Note 1) Double wiring: single, double, 3-position manifold specification sheet.
SNC DP 32
and 4-position solenoid valves can be D-sub Note 1) Note 3) The available number of stations is larger than
used on all manifold stations. SND 16
the number of manifold stations.
Use of a single solenoid will result in an SVA 32 Note 4) Indicate the wiring specifications for mixed single
CC-Link M12
unused control signal. If this is not desired, SVB 16 and double wirings.
order with a specified layout. SDA 32 Note 5) Refer to the S0700 series catalog
EtherCAT M12
Note 2) Specified layout: Indicate the wiring SDB 16 (CAT.NAS11-88) for details.
specifications on the manifold specification SFA 32 ∗ Refer to the S0700 series catalog (CAT.NAS11-88)
sheet. PROFINET M12 for manifold optional parts.
SFB 16
(Note that 2-position double, 3-position ∗ Refer to the S0700 series catalog (CAT.NAS11-88)
SEA 32
and 4-position valves cannot be used EtherNet/IP™ M12 for manifold exploded view.
SEB 16

VQC
where single wiring has been specified.) ∗ When the “SD0” (Without SI unit) is specified, “-D”,
Note 3) Includes the number of blanking plate Note 1) The maximum number of stations is “-Dl” cannot be selected.
assemblies. determined by the total number of
solenoids.
For mixed single and double wirings,
enter “-K” to the order code options.
Note 2) For SI unit part number, refer to page 1.
w Cylinder port size
Symbol Port size Double,
Type of actuation Single
C2 With ø2 One-touch fitting Dual 3-port
C3 With ø3.2 One-touch fitting Number of solenoids 1 2
Metric
C4 With ø4 One-touch fitting
t SI unit output polarity
S0700
CM Mixed sizes and with port plug Note)

N1 With ø1/8" One-touch fitting Nil Positive common


N3 With ø5/32" One-touch fitting Inch N Negative common
NM Mixed sizes and with port plug Note)
Note) Indicate the sizes on the manifold
specification sheet in the case of “CM”, “NM”.

38
Series S0700

How to Order Manifold Assembly

Example (Serial transmission kit)


SS0750-04C4SNAN ···1 set – Manifold base part no.
∗S0720-5······················ 4 sets – Valve part no. (Stations 1 to 4)
∗ Prefix the asterisk to the part nos. of the solenoid valve, etc.
Write sequentially from the 1st station on the D side.
U side When part nos. written collectively are complicated, specified
on the manifold specification sheet.
• Specify the part numbers for valves and options together beneath the

s
n
tio
manifold base part number.

ta
S
3
2
1

e
D sid

How to Order Valves

S07 1 0 5
Type of actuation Voltage: 24 VDC
Symbol Port size
1 2-position single
Function
2 2-position double
Symbol Specification
4-position dual 3-port
Nil Standard
A (N.C. + N.C.)
[Exhaust center] R External pilot Note)
4-position dual 3-port Note) Not applicable for dual
B (N.O. + N.O.) 3-port valves
[Pressure center]
4-position dual 3-port
C (N.C. + N.O.) Base mounted plug-in
Note) Refer to the S0700 series catalog
(CAT.NAS11-88) for symbol.

Refer to the SMC website or the S0700 series catalog (CAT.NAS11-88) for details on
solenoid valve specifications, Common Precautions and Specific Product Precautions.

39
Plug-in Manifold Stacking Base S Kit (Serial Transmission):
For EX260 Integrated-type (For Output) Serial Transmission System Series S0700

Dimensions (mm)

SS0750
S Kit (Serial transmission kit: EX260)
Indicator light

L4

EX260
5.25 L3
L2
38.6 L1 4.4

1.5 (n−1) x 8.5 12.8


(12) (76.7)
8.5
Manual override

14 14 14 14 14 14 14 14

(5.5)
(35)

S0710-5

S0710-5

S0710-5

S0720-5

S0720-5

S0720-5

S07A0-5

S07A0-5

62
72
102.4

SY
39
12 12 12 12 12

21.8

5
≈4
SI unit 4 x M4 mounting hole

D side Stations 1 2 3 4 5 6 7 8 n U side

SV
[Communication connector D-sub]
C8: 3(R) port
C8: ø8 One-touch fitting

DIN rail clamping screw


76.7

76.7
33.6

33.6

2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B

A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4
(12)
(12)

17.5
6.5

9.6
(7.5)

8.5 17.2
(7.5)

VQC
C8: 1(P) port 2n x C3, C4 (4(A), 2(B) port)
C8: ø8 One-touch fitting C3: ø3.2 One-touch fitting
C4: ø4 One-touch fitting

S0700
Dimensions Formula L1 = 8.5n + 31, L2 = 8.5n + 74 n: Station (Maximun 16 stations)
L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 39.5 48 56.5 65 73.5 82 90.5 99 107.5 116 124.5 133 141.5 150 158.5 167
L2 82.5 91 99.5 108 116.5 125 133.5 142 150.5 159 167.5 176 184.5 193 201.5 210
L3 112.5 112.5 125 137.5 137.5 150 162.5 162.5 175 187.5 187.5 200 212.5 212.5 225 237.5
L4 123 123 135.5 148 148 160.5 173 173 185.5 198 198 210.5 223 223 235.5 248

40
EX260
Series
Specific Product Precautions 1
Be sure to read before handling. Refer to back cover for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Design/Selection Mounting

Warning Caution
1. Use this product within the specification range. 4. When lifting a large size manifold solenoid valve unit,
Using beyond the specified specifications range can cause take care to avoid causing stress to the valve connection
fire, malfunction, or damage to the system. joint.
Check the specifications before operation. The connection parts of the unit may be damaged. Because the unit
2. When using for an interlock circuit: may be heavy, carrying and installation should be performed by
• Provide a multiple interlock system which is operated more than one operator to avoid strain or injury.
by another system (such as mechanical protection 5. When placing a manifold, mount it on a flat surface.
function). Torsion in the whole manifold can lead to trouble such as air leakage
• Perform an inspection to confirm that it is working or defective insulation.
properly.
This may cause possible injury due to malfunction. Wiring

Caution Caution
1. When applicable to UL, use a Class 2 power supply unit 1. Check the grounding to maintain the safety of the
conforming to UL1310 for direct current power supply. reduced wiring system and for anti-noise performance.
2. Use this product within the specified voltage range. Provide a specific grounding as close to the unit as possible to
minimize the distance to grounding.
Using beyond the specified voltage range is likely to cause the units
and connecting devices to be damaged or to malfunction. 2. Avoid repeatedly bending or stretching the cable and
applying a heavy object or force to it.
3. Do not install a unit in a place where it can be used as a
foothold. Wiring applying repeated bending and tensile stress to the cable can
break the circuit.
Applying any excessive load such as stepping on the unit by mistake
or placing a foot on it, will cause it to break. 3. Avoid miswiring.
4. Keep the surrounding space free for maintenance. If miswired, there is a danger of malfunction or damage to the
reduced wiring system.
When designing a system, take into consideration the amount of free
space needed for performing maintenance. 4. Do not wire while energizing the product.
5. Do not remove the name plate. There is a danger of malfunction or damage to the reduced wiring
Improper maintenance or incorrect use of operation manual can system or output device.
cause failure and malfunction. Also, there is a risk of losing 5. Avoid wiring the power line and high pressure line in
conformity with safety standards. parallel.
Noise or surge produced by signal line resulting from the power line
Mounting or high pressure line could cause malfunction.Wiring of the reduced
wiring system or output device and the power line or high pressure
Caution line should be separated from each other.
1. When handling and assembling units: 6. Check the wiring insulation.
• Do not apply excessive force to the unit when
Defective insulation (contact with other circuits, improper insulation
disassembling.
between terminals, etc.) may cause damage to the reduced wiring
The connecting portions of the unit are firmly joined with seals.
system or output device due to excessive voltage and current.
• When joining units, take care not to get fingers caught
between units. 7. When a reduced wiring system is installed in
Injury can result. machinery/equipment, provide adequate protection
against noise by using noise filters, etc.
2. Do not drop, bump, or apply excessive impact.
Noise in signal lines may cause malfunction.
Otherwise, the unit can become damaged, malfunction, or fail to
function.
3. Observe the tightening torque range.
Tightening outside of the allowable torque range will likely damage
the screw.
IP67 cannot be guaranteed if the screws are not tightened to the
specified torque.
41
EX260
Series
Specific Product Precautions 2
Be sure to read before handling. Refer to back cover for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions.
The Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Wiring Operating Environment

Caution Caution
8. When connecting wires of output device, prevent water, 2. Provide adequate protection when operating in
solvent or oil from entering inside the connector section. locations such as the following.
This can cause damage, equipment failure or malfunction. Failure to do so may cause damage or malfunction.
The effect of countermeasures should be checked in individual
9. Avoid wiring patterns in which excessive stress is
equipment and machine.
applied to the connector.
1) Where noise is generated by static electricity, etc.
This may cause malfunction or damage to the unit due to contact 2) Where there is a strong electric field
failure. 3) Where there is a danger of exposure to radiation
10 . Select connectors that are ø16 or less if mounting 4) When in close proximity to power lines or high voltage lines
manifolds directly using fieldwireable connectors for SI 3. Do not use in an environment where oil and chemicals
unit power supply wiring. are used.
Using large diameter connectors causes interference with the
Operating in environments with coolants, cleaning solvents, various
mounting surface.
oils or chemicals may cause adverse effects (damage, malfunction)
The following cables with connectors are recommended.
to the unit even in a short period of time.
M For EX260-SPRm/-SDNm/-SECm/-SPNm/-SENm
<Cable with connector>
4. Do not use in an environment where the product could
be exposed to corrosive gas or liquid.
I EX500-APmmm-m
I PCA-1401804/-1401805/-1401806 This may damage the unit and cause it to malfunction.

M For EX260-SMJm 5. Do not use in locations with sources of surge generation.


<Cable with connector> Installation of the unit in an area around the equipment
I EX9-ACmmm-1 (electromagnetic lifters, high frequency induction furnaces, welding
I PCA-1401807/-1401808/-1401809 machine, motors, etc.), which generates the large surge voltage
could cause to deteriorate an internal circuitry element of the unit or
result in damage. Implement countermeasures against the surge
from the generating source, and avoid touching the lines with each
other.
Operating Environment
6. The product is CE marked, but not immune to lightning
Warning strikes. Take measures against lightning strikes in your
system.
1.Do not use in an atmosphere containing an inflammable
gas or explosive gas. 7.Keep dust, wire scraps and other extraneous material
from getting inside the product.
Use in such an atmosphere is likely to cause a fire or explosion. This
system is not explosion-proof. This may cause malfunction or damage.
8. Mount the unit in such locations, where no vibration or
shock is affected.
Caution This may cause malfunction or damage.
1. Select the proper type of enclosure according to the
environment of operation. 9.Do not use in places where there are cyclic temperature
changes.
IP67 is achieved when the following conditions are met.
1) Provide appropriate wiring between all units using electrical wiring In case that the cyclic temperature is beyond normal temperature
changes, the internal unit is likely to be adversely effec-ted.
cables, communication connectors and cables with M12
connectors. 10. Do not use in direct sunlight.
2) Suitable mounting of each unit and manifold valve. Do not use in direct sunlight. It may cause malfunction or damage.
3) Be sure to mount a seal cap on any unused connectors. 11. Use this product within the specified ambient
If using in an environment that is exposed to water splashes, please temperature range.
take measures such as using a cover. This may cause malfunction.
When the enclosure is IP40, do not use in an operating environment
12. Do not use in places where there is radiated heat around it.
or atmosphere where it may come in contact with corrosive gas,
Such a place is likely to cause malfunction.
chemical agents, seawater, water, or water vapor.
When connected to the EX260-SPR5/6/7/8, manifold enclosure is
IP40.

42
EX260
Series
Specific Product Precautions 3
Be sure to read before handling. Refer to back cover for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions.
The Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Adjustment/Operation Maintenance

Warning Warning
1. Do not perform operation or setting with wet hands. 1. Do not disassemble, modify (including circuit board
There is a risk of electrical shock. replacement) or repair this product.
Such actions are likely to cause injuries or breakage.

Caution 2. When an inspection is performed,


• Turn off the power supply.
1. Use a watchmakers’ screwdriver with thin blade for the
• Stop the air supply, exhaust the residual pressurein
setting of each switch of the SI unit.
piping and verify that the air is released before
When setting the switch, do not touch other unrelated
performing maintenance work.
parts.
Unexpected malfunction of system components and injury can
This may cause parts damage or malfunction due to a short circuit. result.
2. Provide adequate setting for the operating conditions.
Failure to do so could result in malfunction. Caution
Refer to the operation manual for setting of the switches.
1. When handling and replacing the unit:
3. For details on programming and address setting, refer to • Do not apply excessive force to the unit when
the manual from the PLC manufacturer. disassembling.
The content of programming related to protocol is designed by the The connecting portions of the unit are firmly joined with seals.
manufacturer of the PLC used.
• When joining units, take care not to get fingers caught
4. For the EX260-SPNm, the side of the SI unit may become between units.
hot. Injury can result.
It may cause burns.
2. Perform periodic inspection.
Unexpected malfunction in the system composition devices is likely
to occur due to malfunction of machinery or equipment.
3.After maintenance, make sure to perform an appropriate
functionality inspection.
In cases of abnormality such as faulty operation, stop operation.
Unexpected malfunction in the system composition devices is likely
to occur.
4. Do not use benzene and thinner for cleaning units.
Damage to the surface or erasure of the display can result.
Wipe off any stains with a soft cloth.
If the stain is persistent, wipe off with a cloth soaked in a dilute
solution of neutral detergent and wrung out tightly, and then finish
with a dry cloth.

Other

Caution
1. Refer to the catalog of each series for Common
Precautions and Specific Product Precautions on
manifold solenoid valves.

M Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

43
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the
labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety
and must be followed in addition to International Standards (ISO/IEC)∗1), and other
safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: Caution indicates a hazard with a low level of risk which, if
not avoided, could result in minor or moderate injury. IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots - Safety.
Warning: Warning indicates a hazard with a medium level of risk
which, if not avoided, could result in death or serious injury.
etc.

Danger indicates a hazard with a high level of risk which, if


Danger : not avoided, will result in death or serious injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating If considering using the product in other industries, consult SMC
conditions, its compatibility with specific equipment must be decided by beforehand and exchange specifications or a contract if necessary.
the person who designs the equipment or decides its specifications If anything is unclear, contact your nearest sales branch.
based on necessary analysis and test results. The expected performance
and safety assurance of the equipment will be the responsibility of the
person who has determined its compatibility with the product. This person Limited warranty and Disclaimer/
should also continuously review all specifications of the product referring
to its latest catalog information, with a view to giving due consideration to
Compliance Requirements
any possibility of equipment failure when configuring the equipment. The product used is subject to the following “Limited warranty and
2. Only personnel with appropriate training should operate Disclaimer” and “Compliance Requirements”.
machinery and equipment. Read and accept them before using the product.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment Limited warranty and Disclaimer
including our products must be performed by an operator who is 1. The warranty period of the product is 1 year in service or 1.5 years
appropriately trained and experienced.
after the product is delivered.∗2)
3. Do not service or attempt to remove product and machinery/ Also, the product may have specified durability, running distance or
equipment until safety is confirmed. replacement parts. Please consult your nearest sales branch.
1. The inspection and maintenance of machinery/equipment should only 2. For any failure or damage reported within the warranty period which
be performed after measures to prevent falling or runaway of the is clearly our responsibility, a replacement product or necessary
driven objects have been confirmed. parts will be provided.
2. When the product is to be removed, confirm that the safety measures This limited warranty applies only to our product independently, and
as mentioned above are implemented and the power from any not to any other damage incurred due to the failure of the product.
appropriate source is cut, and read and understand the specific
product precautions of all relevant products carefully. 3. Prior to using SMC products, please read and understand the
3. Before machinery/equipment is restarted, take measures to prevent warranty terms and disclaimers noted in the specified catalog for
unexpected operation and malfunction. the particular products.
∗2) Vacuum pads are excluded from this 1 year warranty.
4. Contact SMC beforehand and take special consideration of A vacuum pad is a consumable part, so it is warranted for a year after it is
safety measures if the product is to be used in any of the delivered.
following conditions. Also, even within the warranty period, the wear of a product due to the use of
the vacuum pad or failure due to the deterioration of rubber material are not
1. Conditions and environments outside of the given specifications, or use covered by the limited warranty.
outdoors or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways,
air navigation, space, shipping, vehicles, military, medical treatment, Compliance Requirements
combustion and recreation, or equipment in contact with food and
1. The use of SMC products with production equipment for the
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the manufacture of weapons of mass destruction (WMD) or any other
standard specifications described in the product catalog. weapon is strictly prohibited.
3. An application which could have negative effects on people, property, 2. The exports of SMC products or technology from one country to
or animals requiring special safety analysis. another are governed by the relevant security laws and
4. Use in an interlock circuit, which requires the provision of double regulations of the countries involved in the transaction. Prior to
interlock for possible failure by using a mechanical protective function, the shipment of a SMC product to another country, assure that all
and periodical checks to confirm proper operation. local rules governing that export are known and followed.

Revision history
Edition B I EtherNet/IP™ added to applicable Fieldbus protocols.
QS

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

44
Global Manufacturing, Distribution and Service Network
Worldwide Subsidiaries
America
North & South America Asia/Oceania Europe/Africa
U.S.A. SMC Corporation of America SRI LANKA (Distributor) Electro-Serv(Pvt.)Ltd. CZECH REPUBLIC SMC Industrial Automation CZ s.r.o.
CANADA SMC Pneumatics (Canada) Ltd. IRAN (Distributor) Abzarchian Co. Ltd. HUNGARY SMC Hungary Ipari Automatizálási Kft.
MEXICO SMC Corporation(México), S.A. de C.V. U.A.E. (Distributor) Machinery People Trading Co. L.L.C. POLAND SMC Industrial Automation Polska Sp. z o.o.
BRAZIL SMC Pneumãticos do Brasil Ltda. KUWAIT (Distributor) Esco Kuwait Equip & Petroleum App. Est. SLOVAKIA SMC Priemyselná Automatizácia Spol s.r.o.
CHILE SMC Pneumatics (Chile) S.A. SAUDI ARABIA (Distributor) Assaggaff Trading Est. SLOVENIA SMC Industrijska Avtomatika d.o.o.
COLOMBIA SMC Colombia Sucursal de SMC Chile S.A. BAHRAIN (Distributor) BULGARIA SMC Industrial Automation Bulgaria EOOD
Mohammed Jalal & Sons W.L.L. Technical & Automative Services
ARGENTINA SMC Argentina S.A. CROATIA SMC Industrijska Automatika d.o.o.
SYRIA (Distributor) Miak Corporation
BOLIVIA SMC Pneumatics Bolivia S.r.l. BOSNIA AND HERZEGOVINA(Distributor) A.M. Pneumatik d.o.o.
JORDAN (Distributor) Atafawok Trading Est.
VENEZUELA SMC Neumatica Venezuela S.A. SERBIA(Distributor) Best Pneumatics d.o.o.
BANGLADESH (Distributor) Chemie International
PERU (Distributor) IMPECO Automatización Industrial S.A.C. UKRAINE(Distributor) PNEUMOTEC Corp.
AUSTRALIA SMC Pneumatics(Australia)Pty.Ltd.
ECUADOR (Distributor) ASSISTECH CIA. LTDA. FINLAND SMC Pneumatics Finland Oy
NEW ZEALAND SMC Pneumatics(N.Z.)Ltd.
NORWAY SMC Pneumatics Norway AS
Asia/Oceania JAPAN SMC Corporation
SWEDEN SMC Pneumatics Sweden AB
CHINA SMC(China)Co.,Ltd.
ESTONIA SMC Pneumatics Estonia Oü
CHINA SMC Pneumatics (Guangzhou) Ltd. Europe/Africa
LATVIA SMC Pneumatics Latvia SIA
HONG KONG SMC Pneumatics(Hong Kong)Ltd. GERMANY SMC Pneumatik GmbH
LITHUANIA(LIETUVA) UAB “SMC Pneumatics”
TAIWAN SMC Pneumatics(Taiwan)Co.,Ltd. SWITZERLAND SMC Pneumatik AG
ROMANIA SMC Romania S.r.l.
KOREA SMC Pneumatics Korea Co., Ltd. U.K. SMC Pneumatics (U.K.) Ltd.
RUSSIA SMC Pneumatik LLC.
SINGAPORE SMC Pneumatics(S.E.A.)Pte.Ltd. FRANCE SMC Pneumatique SA
KAZAKHSTAN SMC Kazakhstan, LLC.
MALAYSIA SMC Pneumatics(S.E.A.)Sdn.Bhd. SPAIN / PORTUGAL SMC España S.A.
TURKEY (Distributor) Entek Pnömatik Sanayi ve. Ticaret Şirketi
THAILAND SMC (Thailand) Ltd. ITALY SMC Italia S.p.A.
MOROCCO (Distributor) Soraflex
PHILIPPINES Shoketsu SMC Corporation GREECE SMC HELLAS E.P.E
TUNISIA (Distributor) Byms
INDIA SMC Pneumatics(India)Pvt.Ltd. IRELAND SMC Pneumatics (Ireland) Ltd.
EGYPT (Distributor) Saadani Trading & Industrial Services
ISRAEL (Distributor) Baccara Geva A.C.S. Ltd. NETHERLANDS (Associated company) SMC Pneumatics BV
NIGERIA (Distributor) Faraday Engineering Company Ltd.
INDONESIA (Distributor) PT. Sinar Mutiara Cemerlang BELGIUM (Associated company) SMC Pneumatics N.V./S.A.
SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd.
VIETNAM (Distributor) Dy Dan Trading Co.,Ltd. DENMARK SMC Pneumatik A/S
PAKISTAN (Distributor) Jubilee Corporation AUSTRIA SMC Pneumatik GmbH (Austria)

U.S. & Canadian Sales Offices

WEST EAST
Austin Atlanta
Dallas Birmingham
Los Angeles Boston
Phoenix Charlotte
Vancouver
Portland Nashville
San Francisco New Jersey Montreal
Vancouver Toronto
Richmond
Detroit
Rochester Boston
Tampa Chicago
CENTRAL
Chicago Montreal
Livermore
Cincinnati Indianapolis
Cleveland
Detroit
Atlanta
Indianapolis
Milwaukee
Sales Branches
Minneapolis
Regional Distribution Centers
St. Louis Austin
Central warehouse
Toronto
Windsor
SMC Corporation of America
10100 SMC Blvd., Noblesville, IN 46060
www.smcusa.com
SMC Pneumatics (Canada) Ltd.
www.smcpneumatics.ca

(800) SMC.SMC1 (762-7621)


e-mail: sales@smcusa.com
For International inquiries: www.smcworld.com
© 2012 SMC Corporation of America, All Rights Reserved. QT-RRD-5M
All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing. However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice.

You might also like