Methodology
• DC input from either high voltage or low voltage side would be converted to high
frequency square wave
• High frequency transformer serves the purposes of isolation as well as stepping up or
down of voltage level
Hardware Components Hardware Results
• HF square wave will be rectified to achieve the output voltage reference
• EMI filters are designed for noiseless input and output
• Voltage sensor is designed for feedback in closed loop
• PID control loop is implemented to minimize error in output
• Both inverter and rectifier circuits use efficient SiC based MOSFETs and efficient gate
drivers in Dual Active Bridge (DAB) Topology
Block Diagram
Customized
Low High Frequency Full Bridge High
EMI High EMI
Voltage Full Bridge Controlled Voltage
Filter Frequency Filter
DC Inverter Circuit Rectifier DC
Transformer
Voltage Mode
Voltage
Sensor Charging Selection
Discharging Sensor
Applications
PID Control • Hybrid Electric Vehicles (HEV) • Residential Energy Storage System
• Uninterruptible Power Supplies (UPS) • Core circuit of the next generation medium
• Fuel cell energy systems voltage conversion system
A/D Conversion & Optical Isolation • Energy storage in renewable energy • Telecom
systems • Solar cells
Group Members • PC servers