900 Results

C, kPa 55.2
f, deg 31.6
Tan(f) 0.62

600
Shear Stress, kPa

300

0
0 300 600 900 1200 1500 1800

Normal Stress, kPa

1500
Sample No. 1 2 3
Water Content, % 18.2 18.2 18.1
1250 Dry Density, g/cm3 1.74 1.74 1.74
Initial

Saturation, % 89.2 89.0 88.9


Void Ratio 0.5507 0.5507 0.5507
Deviator Stress, kPa

1000 Diameter, cm. 7.20 7.20 7.20


3 Height, cm. 14.40 14.40 14.40
Water Content, % 18.2 18.2 18.2
750 Dry Density, g/cm3 1.74 1.74 1.74
At Test

Saturation, % 89.2 89.2 89.2


Void Ratio 0.5507 0.5507 0.5507
500 2 Diameter, cm. -- -- --
Height, cm. -- -- --
1 Strain at peak, % 5.5 5.7 7.5
250 Back Pressure, kPa 0 0 0
Cell Pressure, kPa 100 200 400
0 Fail. Stress, kPa 413 637 1091
0 5 10 15 20
Strain, % 5.5 5.7 7.5
Axial Strain, % Ult. Stress, kPa
Strain, %
s1 Failure, kPa 513 837 1491
Type of Test:
s3 Failure, kPa 100 200 400
Unconsolidated Undrained
Sample Type: Client: POLO VALENCIA MILTON
Description: silty sand
Project: DISEÑO Y CONSTRUCCIÓN DE UN EDIFICIO DE
LL= NP VIVIENDA MULTIFAMILIAR
Assumed Specific Gravity= 2.7 Remarks: Source of Sample: TERRENO NATURAL/C-1/M-2
UBICACION: Jr. Ayacucho N°560/ Sample Number: C389 Depth: 1.85-3.15
Vista Alegre/Victor Larco/Trujillo Proj. No.: -- Date Sampled: 25/06/2019
TRIAXIAL SHEAR TEST REPORT

Figure 01 GEOCONS.SRL
Tested By: FA Checked By: RZ
1250 1250
1 2

1000 1000
Deviator Stress

Deviator Stress
750 750
kPa

kPa
500 500

250 250

0 0
0% 8% 16% 0% 8% 16%

1250 1250
3 4

1000 1000
Deviator Stress

Deviator Stress
750 750
kPa

kPa
500 500

250 250

0 0
0% 8% 16% 0% 8% 16%

900 Peak Strength


Total
a= 43.7 kPa
a= 27.9 deg
tan a= 0.53
600
q, kPa

300

0
0 300 600 900 1200 1500 1800

p, kPa

Client: POLO VALENCIA MILTON


Project: DISEÑO Y CONSTRUCCIÓN DE UN EDIFICIO DE VIVIENDA MULTIFAMILIAR
Source of Sample: TERRENO NATURAL/C-1/M-2 Depth: 1.85-3.15 Sample Number: C389
Project No.: -- Figure 02 GEOCONS.SRL

Tested By: FA Checked By: RZ


PHOTOS
SAMPLE A SAMPLE B SAMPLE C
NORMAL STRESS NORMAL STRESS NORMAL STRESS
100 kPa 200 kPa 400 kPa

Client: POLO VALENCIA MILTON


TRIAXIAL SHEAR TEST REPORT
Project: DISEÑO Y CONSTRUCCIÓN DE UN EDIFICIO DE VIVIENDA MULTIFAMILIAR

GEOCONS.SRL Source Sample: TERRENO NATURAL/C-1/M-2


Sample Number: C389
Depth: 1.85-3.15

Project Number: -- Date Sampled : 25/06/2019