FLUID MANAGEMENT SYSTEM

Product Manual PAGE 1


Package Units
Main Controller Unit (1 for 4 tanks & 2 motors)
▻ LCD Display
▻ Wi-Fi Configuration Switch
▻ RJ45 ports for motors’ connection
Heat ▻ Extended cables for sensors’ connection
shrinked

Motor Controller Unit (one per motor)


▻ Mode Control Switch (Auto / Manual)
▻ AC inline connectors
▻ RJ45 port
Cat 6 – RJ45 Crimp
4-core 7/39 cable

Sensor Unit (one per sensor)


2:1

▻ Ultrasonic Sensor
4:1

▻ Extended Cable
Cables (length as per site dimension)
▻ 4-core 7/39 Cable
▻ Cat 5 Cable
Miscellaneous
▻ 220-250 AC to 12V-12A DC Power Adaptor
heat
shrinked ▻ 2mm & 6mmheat shrink tubes
▻ Aluminium strips(2) & cable ties
FLUID MANAGEMENT SYSTEM
Product Manual PAGE 2
Cable Details ▻ Place the 2mm heat shrink tubes over the exposed
(1) Main Controller ßà Sensor joints and heat them with flame
▻ Place the 6mm heat shrink tube over all joints heat with
▻ Main Controller should be connected to sensors via 4- flame
core (7/39) data cables
▻ You can find 4 sets of 4-core data cable protruding from
the main controller unit, one per tank. Similarly, each
sensor shall have a 4-core data cable protruding.
▻ Each of these 4 sets are marked 1, 2, 3 and 4 using
ferrule. These correspond to port numbers in the (2) Main Controller ßà Motor Controller
configuration screen of the LemonBee Mobile App ▻ Main Controller should be connected to motor controller
▻ 4-core (7/39) data cable can be joined with one another via CAT 5 cable
as per instructions given below: ▻ RJ45 socket is provided in main controller & in motor
▻ Insert the 6 mm heat shrink tube to one end of the controller
cable & Insert the 2 mm heat shrink tube to ▻ CAT 5 cables
individual wires on one end can be
▻ Join all 4 wires by twisting the strands with connected to
matching colors one other
through
2 mm tubes
6 mm tube crimping
4-core cable using RJ 45
Jack
FLUID MANAGEMENT SYSTEM
Product Manual PAGE 3
Installation Procedure

STEP 1 Main Controller Unit Without


LEMONBEE
▻ Fix on a suitable wall where there is a provision of AC à
power plug nearby and good availability of Wi-Fi signal
▻ Routing of wires to tanks and motors should be easy & of
minimal distance

STEP 2 Motor Controller Unit


▻ Fix on a suitable wall near the motor switch
▻ Remove existing 230V wires from the motor switch.
Connect neutral directly to motor.
▻ Connect the main AC input to point #1 (see following With
diagram) of the controller LEMONBEE
▻ Connect point #2 (see diagram below) of controller to à
the motor switch input.
▻ Connect point #3 (see diagram below) of controller to
the motor via the motor switch output point.
FLUID MANAGEMENT SYSTEM
Product Manual PAGE 4
Installation Procedure – contd..
▻ In case of an underground tank such as sump tank,
STEP 3 Sensor Unit ▻ Route the cable through a hole or groove in the
ground to allow free movement of sump lid
▻ Make sure that the cable from main controller reaches ▻ Make sure the sensor cable is protected from
the tank lid with sufficient length for opening/closing the damages due to external forces
tank lid
▻ Join the cable from main controller and sensor cable, as STEP 4 Installation Wrap-up Checklist
described in “Cable details” section
▻ Attach the sensor unit to aluminium strip with the help of ▻ The power adaptor needs to be plugged in AC point &
cable ties the DC pin needs to be inserted in the main
▻ Fix the aluminium strip with the sensor touching the controller’s power-in port
inner surface of the lid, and, facing the water ▻ All tank depths are measured in centimeter units.
▻ All cables to tanks and sensors are connected
properly and insulated
▻ Port (Cable) numbers are noted down for respective
tanks
▻ Motor controller socket (Left side: Port 1, Right Side:
Port 2) numbers are noted for respective motors
▻ Switch on the AC adaptor and check if LCD display is
ON and the LEMONBEE version number is
displayed.
Bottom Surface (Water Facing) Top Surface
FLUID MANAGEMENT SYSTEM
Product Manual PAGE 5
Installation Procedure – contd..
Motors & Tanks Configuration
▻ Go to the Device Configuration Option
STEP 5 Configuration ▻ Use the Add Motor option to configure the following for
each motor: name, max run stretch time, minimum gap
▻ Download LemonBee app from Google Play Store in your between runs, port number, source tank details (name,
android mobile phone minimum retain level, port number), if any.
▻ You need to have an administration key to be able to ▻ Use the Add Tank option to configure the following for
configure the device each overhead tank: name, depth, overflow level,
minimum maintain level, port number.
Wi-Fi Configuration ▻ Save the configuration and in a few minutes, the device
▻ Press and hold the Wi-Fi Reset button (RED) on the will be updated with the configuration
main controller for a few seconds
▻ From your mobile, connect to “LemonBee” Wi-Fi.
▻ Go to Device Configuration option in the LemonBee
App and use the Get Device ID option to configure Now you are all set to relax and just
the Device ID (of main controller) in the app. ▻ View the motor statuses & tank levels in the app and in
▻ Use the Wi-Fi Configuration option of LemonBee App the main controller
to scan available Wi-Fi networks and add the one ▻ See the motors being switched ON/OFF automatically
you prefer along with the password. based on your configuration
▻ After a couple of minutes, the main controller would ▻ Switch ON/OFF motors as you require
receive the configured Wi-Fi network & connect to it. ▻ Change configuration as you require
FLUID MANAGEMENT SYSTEM
Product Manual PAGE 6
LemonBee App – Configuration Guide Tank Overflow Level – Depth of water (usually of overhead
tanks) at which the motor should be switched OFF
Motors Parallel Run – Allowing/disallowing simultaneous
Min Maintain Level – Depth of water at which the motor
running of more than one motor
should be switched OFF
Quiet Period – No automatic switching ON of motors during
Source Min Retain Level – The depth of water in the source
this period, to avoid disturbance to neighbours and self
(usually of underground sump tank), beyond which water
Max Run Stretch Time – maximum time period for which a should not be pumped up.
motor is allowed to run when switched ON. Motor will be
Linking & Setting Preference – After adding tanks and
switched OFF automatically once max run stretch time is
motors, you need to link motors to tanks. In case of linking
crossed
multiple motors to the same overhead tank, you can set the
Min Gap Between Runs – To avoid frequent running of preferred motor for each overhead tank. If an overhead tank
motors, users can configure the minimum time gap that needs to be filled in, the most preferred tank will be switched
should be maintained between two runs of a motor ON first.

Source Monitorable? – Every motor has a source to pump Terms & Conditions
water from. In case of bore motor, the source (bore well) is
not monitorable. In case of sump motor, the sump tank ▻ Warranty is limited to manufacturing defects of the
needs to be monitored to check if the sump tank has product for a period of 1 year from date of purchase
sufficient source to pump water from it. ▻ Claims and damages are limited only to the extent of the
value of product purchased.
Tank Depth – Distance between bottom of the tank and the ▻ Legal jurisdiction for settling any disputes will be limited
sensor (in centimeters) to courts in Chennai.
FLUID MANAGEMENT SYSTEM
Product Manual PAGE 7
Troubleshooting

Issue Tip(s)

LCD Display in Motor Controller is not switching ON ü Check AC power availability in the plug point
ü Check if the DC power input is properly inserted
Mobile App Notification: Motor is switched ON, but is not Check if the motor has power and is running in Manual Mode.
running ü If yes, contact our customer support.
ü If not, use your local electrician to fix the motor connection
Mobile App Notification: Motor is switched ON, but is not Check if the water is available in the source tank or bore well. In
pumping water up case of air locked, seek help from local plumber
Mobile App Notification: Sensor Placement Error Check if the sensor is dislocated under the lid
Mobile App Notification: Sensor Connection Error Check if the cable to sensor is cut or damaged
Erratic values of tank levels Check if the sensor is dislocated under the lid
Erratic ON/OFF of motors ü Check if the RJ45 connection to motor controller is in tact
ü Check if the configuration is proper and logical

In case you face issues that are not listed above, or, if the tips above do not help in resolving the issue, please switch the motors
to manual mode and contact us via email (support@thingksinfomatics.com) or Call (0091 - 94430 36763)