Professional Documents
Culture Documents
Flexpower Two FXR: Fully Pre-Wired Dual Inverter System
Flexpower Two FXR: Fully Pre-Wired Dual Inverter System
F U L LY P R E - W I R E D D UA L I N V E R T E R S Y S T E M
3 . E A S Y - T O - I N S TA L L A N D M A I N TA I N
• Factory tested, pre-wired and pre-configured
Generator Load Sub Panel Energy Storage
• Fast installation—just hang on the wall with included bracket
and make all necessary connections
• Field-serviceable modular design and global technical support
• Monitor, command and control from any internet-connected
device with OPTICS RE
OUTBACK POWER—MASTERS OF THE OFF-GRID. FIRST CHOICE FOR THE NEW GRID.
OutBack reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group. 1
FLEXpower TWO S P E C I F I C AT I O N S 04/2017
*FLEXpower TWO FXR systems include a mounting bracket, two FXR/VFXR inverter/chargers, two FLEXmax charge controllers, MATE3, HUB10.3, FLEXnet DC, FLEXware surge protector, AC and DC wiring boxes, battery and PV array breakers, PV GFDI, Input-
Output-Bypass assembly, mounting locations for GFCI outlets and additional AC breakers.
Additional configurations available. ** Overcurrent protective device.
For North America Description Inverter(s) FW-X240 Bypass Outlet Inverter OCPD** PV OCPD** RTS
FP2 VFXR3524A Dual VFXR3524A, 7.0kW FLEXpower TWO VFXR3524A (x2) — 240VAC Bypass — 250A 80A Yes
FP2 VFXR3648A Dual VFXR3648A, 7.2kW FLEXpower TWO VFXR3648A (x2) — 240VAC Bypass — 175A 80A Yes
FP2 FXR3048A Dual FXR3048A, 6.0kW FLEXpower TWO FXR3048A (x2) — 240VAC Bypass — 250A 80A Yes
FP2 FXR2524A Dual FXR2524A, 5.0kW FLEXpower TWO FXR2524A (x2) — 240VAC Bypass — 175A 80A Yes
VFXR3648A Power Factor Chart VFXR3648A Power Rating Chart VFXR3648A Efficiency Rating Chart
1.0 8000 100% 93% (Typical)
3.6kVA 3.6kW 3.6kVA 91% (CEC)
90%
0.85
3.06kW 6000VA 80%
0.75 6000 5400VA
70%
Power Factor
60%
Power (VA)
Efficiency
0.5 4000 3600VA 50%
4000VA
40%
30%
0.25 2000
20%
10%
0.0 0 0%
Industry-Standard Non-Industry Standard 100ms 5 sec 30 min continuous 1kVA 2kVA 3kVA 4kVA
For Europe Description Inverter(s) FW-X240 Bypass Outlet Inverter OCPD** PV OCPD** RTS
FP2 VFXR3024E Dual VFXR3024E, 6.0kW FLEXpower TWO VFXR3024E (x2) — 230VAC Bypass — 175A 80A Yes
FP2 VFXR3048E Dual VFXR3048E, 6.0kW FLEXpower TWO VFXR3048E (x2) — 230VAC Bypass — 250A 80A Yes
VFXR3048E Power Factor Chart VFXR3048E Power Rating Chart VFXR3048E Efficiency Rating Chart
1.0 8000 100% 93% (Typical)
3.0kVA 3.0kW 3.0kVA
90%
0.85
2.55kW 80%
0.75 6000 5750VA
5175VA 70%
Power Factor
60%
Power (VA)
Efficiency
OutBack reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group. 2