Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

FLEXpower TWO FXR

F U L LY P R E - W I R E D D UA L I N V E R T E R S Y S T E M

Three Reasons to Choose the FLEXpower TWO


from OutBack Power:

1. ENGINEERED FOR RELIABILIT Y


• Ideal for full-size solutions: homes, farms, small businesses,
backup power
• Available in sealed or vented units with die-cast aluminum
chassis
• Extensive quality and reliability testing, including Highly
Accelerated Life Testing (HALT)
• 15 years of experience manufacturing and improving products
for fault-intolerant, mission-critical applications
• Standard 5 year warranty (extended 10 year warranty available)

OutBack FLEXpower TWO Typical System


2. DESIGNED FOR FLEXIBILIT Y Integration (w/ 2 FXR/VFXR Inverter/Chargers):
• Available in seven models for 120VAC or 230VAC applications
• Seven different programmable operational modes, Power Flow
with generator assist
• Advanced Battery Charging (ABC) programmability PV Source

• GridZero operating mode minimizes grid dependence in areas


where incentives are changing and utility sell-back is limited
• Sinewave output in 12V, 24V or 48V versions with a typical
operating efficiency up to 93%, field selectable 50Hz/60Hz Main Panel FLEXpower TWO
• Sealed models available for operating in harsh environments
• Sealed Models: 5000VA or 6000VA
Vented Models: 6000VA, 7000VA or 7200VA
Grid

3 . E A S Y - T O - I N S TA L L A N D M A I N TA I N
• Factory tested, pre-wired and pre-configured
Generator Load Sub Panel Energy Storage
• Fast installation—just hang on the wall with included bracket
and make all necessary connections
• Field-serviceable modular design and global technical support
• Monitor, command and control from any internet-connected
device with OPTICS RE

OUTBACK POWER—MASTERS OF THE OFF-GRID. FIRST CHOICE FOR THE NEW GRID.

MAKE THE POWER STORE THE ENERGY MANAGE THE SYSTEM


• FLEXpower Integrated Systems • EnergyCell RE, GH, NC and OPzV Batteries • OPTICS RE System Monitoring and Control
• Inverter/Chargers & Charge Controllers • Battery Enclosures and Racking • MATE3 System Display and Communications

OutBack reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group. 1
FLEXpower TWO  S P E C I F I C AT I O N S 04/2017

Details FLEXpower TWO FXR


Finished Dimensions H x W x D (in/cm) 20.25 x 46.5 x 13.0 / 51 x 118 x 33
Weight (lb/kg) 256 / 116

*FLEXpower TWO FXR systems include a mounting bracket, two FXR/VFXR inverter/chargers, two FLEXmax charge controllers, MATE3, HUB10.3, FLEXnet DC, FLEXware surge protector, AC and DC wiring boxes, battery and PV array breakers, PV GFDI, Input-
Output-Bypass assembly, mounting locations for GFCI outlets and additional AC breakers.
Additional configurations available.  ** Overcurrent protective device.

For North America Description Inverter(s) FW-X240 Bypass Outlet Inverter OCPD** PV OCPD** RTS
FP2 VFXR3524A Dual VFXR3524A, 7.0kW FLEXpower TWO VFXR3524A (x2) — 240VAC Bypass — 250A 80A Yes
FP2 VFXR3648A Dual VFXR3648A, 7.2kW FLEXpower TWO VFXR3648A (x2) — 240VAC Bypass — 175A 80A Yes
FP2 FXR3048A Dual FXR3048A, 6.0kW FLEXpower TWO FXR3048A (x2) — 240VAC Bypass — 250A 80A Yes
FP2 FXR2524A Dual FXR2524A, 5.0kW FLEXpower TWO FXR2524A (x2) — 240VAC Bypass — 175A 80A Yes

VFXR3648A Power Factor Chart VFXR3648A Power Rating Chart VFXR3648A Efficiency Rating Chart
1.0 8000 100% 93% (Typical)
3.6kVA 3.6kW 3.6kVA 91% (CEC)
90%
0.85
3.06kW 6000VA 80%
0.75 6000 5400VA
70%
Power Factor

60%
Power (VA)

Efficiency
0.5 4000 3600VA 50%
4000VA
40%
30%
0.25 2000
20%
10%
0.0 0 0%
Industry-Standard Non-Industry Standard 100ms 5 sec 30 min continuous 1kVA 2kVA 3kVA 4kVA

Power Rating Notes Instantaneous Power Rating INVERTING SELLING


Inverters that specify power in VA but do not use the Most stringent, massive load start  VFXR3648A: 6000VA
Typical Efficiency Rating
unity standard Power Factor (PF) could have misleading Surge Power Rating Real world efficiency with variable loads  VFXR3648A: 93%
power specifications. Volt-Amps (VA) is a total inverter Less stringent load start  VFXR3648A: 5400VA
output, while Watts (W) represent the power consumed by the CEC Efficiency Rating
Peak Power Rating Most stringent US rating  VFXR3648A: 91%
electrical loads. PF, which varies by types of loads, is the ratio Frequent “heavy duty” load requirements  VFXR3648A: 4000VA
of W to VA, and the difference between the two is power in the
circuit that does no useful work. At 1.0PF (unity), all power is Continuous Power Rating
used. This is the industry-standard used by OutBack Power. Sustained “real world” load requirements  VFXR3648A: 3600VA

For Europe Description Inverter(s) FW-X240 Bypass Outlet Inverter OCPD** PV OCPD** RTS
FP2 VFXR3024E Dual VFXR3024E, 6.0kW FLEXpower TWO VFXR3024E (x2) — 230VAC Bypass — 175A 80A Yes
FP2 VFXR3048E Dual VFXR3048E, 6.0kW FLEXpower TWO VFXR3048E (x2) — 230VAC Bypass — 250A 80A Yes

VFXR3048E Power Factor Chart VFXR3048E Power Rating Chart VFXR3048E Efficiency Rating Chart
1.0 8000 100% 93% (Typical)
3.0kVA 3.0kW 3.0kVA
90%
0.85
2.55kW 80%
0.75 6000 5750VA
5175VA 70%
Power Factor

60%
Power (VA)

Efficiency

0.5 4000 50%


40%
3300VA
3000VA 30%
0.25 2000
20%
10%
0.0 0 0%
Industry-Standard Non-Industry Standard 100ms 5 sec 30 min continuous 1kVA 2kVA 3kVA 4kVA

Power Rating Notes Instantaneous Power Rating INVERTING SELLING


Inverters that specify power in VA but do not use the Most stringent, massive load start  VFXR3048E: 5750VA
Typical Efficiency Rating
unity standard Power Factor (PF) could have misleading Surge Power Rating Real world efficiency with variable loads  VFXR3048E: 93%
power specifications. Volt-Amps (VA) is a total inverter Less stringent load start  VFXR3048E: 5175VA
output, while Watts (W) represent the power consumed by the Peak Power Rating
electrical loads. PF, which varies by types of loads, is the ratio Frequent “heavy duty” load requirements  VFXR3048E: 3300VA
of W to VA, and the difference between the two is power in the
circuit that does no useful work. At 1.0PF (unity), all power is Continuous Power Rating
used. This is the industry-standard used by OutBack Power. Sustained “real world” load requirements  VFXR3048E: 3000VA

OutBack reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group. 2

You might also like