Professional Documents
Culture Documents
Hydraulic
Hydraulic
SR NO SUBJECT
1 Data
1.1 Bridge Data
1.2 River Data
2 Discharge Calculations Summary & Obstruction Calculations
2.1 Summary
2.2 Obstruction Calculations
2.3 Afflux Calculations
3 Scour Depth Calculations
4 Summary Of Hydraulic Features
5 George Data
6 Discharge Calculations
1
17032-MB-PS-DC-0013-01-R0
2
17032-MB-PS-DC-0013-01-R0
4
17032-MB-PS-DC-0013-01-R0
6 DISCHARGE CALCULATIONS:
6.1 OBSERVED HFL:
6.1.1 DISCHARGE:
HFL = 274.009 m
2 1
Q = AV = A R 3
S 2
A P R Q
m2 m m m3/s
C1 0.00 0.00 0.00 0.00
C2 13.59 12.77 1.06 22.42
C3 7.37 18.00 0.41 6.43
TOTAL 20.95 28.9
6.1.2 CALCULATIONS:
C-1 Chainage GL HFL HT AVG Dist. C/S area Ht. Diff. Wetted
HT Perimeter
(m) (m) (m) (m) (m) (m) (m2) (m) (m)
-3.344 274.009 274.009 0.000
0.0000 0.0000
C-2 Chainage GL HFL HT AVG Dist. C/S area Ht. Diff. Wetted
HT Perimeter
(m) (m) (m) (m) (m) (m) (m2) (m) (m)
-3.344 274.009 274.009 0.000 0.2 1.34 0.206 0.307 1.378
-2.000 273.702 274.009 0.307 0.6 2.00 1.207 0.593 2.086
0.000 273.109 274.009 0.900 0.6
2.000 272.786 274.009 1.223 1.1 2.00 2.123 0.323 2.026
4.000 272.543 274.009 1.466 1.3 2.00 2.689 0.243 2.015
6.000 272.536 274.009 1.473 1.5 2.00 2.939 0.007 2.000
8.000 272.663 274.009 1.346 1.4 2.00 2.819 0.127 2.004
9.250 272.792 274.009 1.217 1.3 1.25 1.602 0.129 1.257
13.59 12.7655
5
17032-MB-PS-DC-0013-01-R0
6.2.2 CALCULATIONS:
C-1 Chainage GL HFL HT AVG Dist. C/S area Ht. Diff. Wetted
HT Perimeter
(m) (m) (m) (m) (m) (m) (m2) (m) (m)
-3.059 273.944 273.944 0.000
0.000 0.000
6
17032-MB-PS-DC-0013-01-R0
C-3 Chainage GL HFL HT AVG Dist. C/S area Ht. Diff. Wetted
HT Perimeter
(m) (m) (m) (m) (m) (m) (m2) (m) (m)
9.250 272.792 273.944 1.152
10.000 272.869 273.944 1.075 1.1 0.75 0.835 0.077 0.754
12.000 273.022 273.944 0.922 1.0 2.00 1.997 0.153 2.006
14.000 273.039 273.944 0.905 0.9 2.00 1.827 0.017 2.000
16.000 273.340 273.944 0.604 0.8 2.00 1.509 0.301 2.023
18.000 273.941 273.944 0.003 0.3 2.00 0.607 0.601 2.088
18.043 273.944 273.944 0.000 0.0 0.04 0.000 0.003 0.043
6.775 8.914
7
17032-MB-PS-DC-0013-01-R0
6.3.1 DISCHARGE:
Q = 31.85 m3/s
2 1
Q = AV =
A R 3
S 2
A P R Q
m2 m m m3/s
C1 0.00 0.00 0.00 0.00
C2 14.43 13.06 1.10 24.43
C3 8.65 21.72 0.40 7.42
TOTAL 23.09 31.85 Diff = 0.00 m3/s
6.3.2 CALCULATIONS:
C-1 Chainage GL HFL HT AVG Dist. C/S area Ht. Diff. Wetted
HT Perimeter
(m) (m) (m) (m) (m) (m) (m2) (m) (m)
-3.635 274.076 274.076 0.000
0.0000 0.0000
C-2 Chainage GL HFL HT AVG Dist. C/S area Ht. Diff. Wetted
HT Perimeter
(m) (m) (m) (m) (m) (m) (m2) (m) (m)
-3.635 274.076 274.076 0.000 0.2 1.64 0.306 0.374 1.677
-2.000 273.702 274.076 0.374 0.7 2.00 1.340 0.593 2.086
0.000 273.109 274.076 0.967 0.7
2.000 272.786 274.076 1.290 1.1 2.00 2.256 0.323 2.026
4.000 272.543 274.076 1.533 1.4 2.00 2.822 0.243 2.015
6.000 272.536 274.076 1.540 1.5 2.00 3.072 0.007 2.000
8.000 272.663 274.076 1.413 1.5 2.00 2.952 0.127 2.004
9.250 272.792 274.076 1.284 1.3 1.25 1.685 0.129 1.257
14.435 13.0648
8
17032-MB-PS-DC-0013-01-R0