COLUMN DESIGN ACCORDING TO EBCS-2-1995

ON AXIS 3,I
ROOF COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 30X30

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 302.36 kn

T
TPU
AXIS I-I 33.64 TOP
M 3-3
-37.49 BOTTOM
S OU
-15.2 TOP
ETAB

M 2-2
AXIS 3-3 26.36 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS(M) 3-3
* Double curvature
ABOUT AXIS(M) 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

3.3
= 0.4126

= 0.8252

= 0.6189

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.7181
le= 236.97
R= 75

= 3.1596

λlimit= 72.433
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING
L 5 L 5

L 3.3

L 5 L 5

3.3

= 0.4126
= 0.8252

= 0.6189

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.7181
le= 236.97
R= 8.6603

= 27.363

λlimit= 64.416
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -33.64
M2 37.49
FOR M 2-2
M1 -15.2
M2 26.36

B H
COLUMN SIZE(@ FLOOR) 30 30
COLUMN SIZE(@ BELOW) 30 30
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 900

DESIGN MOMENT FOR M 3-3


e01= -0.1113
e02= 0.124 The equivalent moment
eeq= 0.0496
ea= 0.02
ed= 0.144
Msd 3-3 43.537
DESIGN MOMENT FOR M 2-2
e01= -0.0503
e02= 0.0872
eeq= 0.0349
ea= 0.02
ed= 0.1072
Msd 2-2 32.407

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 νsd
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.2
Use biaxial chart number 18, since
From biaxial chart No 18
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 720 mm2

A,smax 7200 mm2


Since
On each face
A 180
using diameter 14 bar on each face provide
2 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 204.55
COLUMN STIFFNESS @ BELOW(KI) 204.55

The equivalent moment

0.014
0.011
0.3

length to rebar center

r 18, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
5th FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 30X30

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 745.48 kn

T
AXIS I-I 20.01 TOP TPU
M 3-3
-39.22 BOTTOM
S OU

6.41 TOP
ETAB

M 2-2
AXIS 3-3 -15.11 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS(M) 3-3
* Double curvature
ABOUT AXIS(M) 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

3.3
= 0.4126

= 1.7167

= 1.0647

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.7855
le= 259.21
R= 75

= 3.4561

λlimit= 62.755
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 3.3

L 5 L 5

3.3
= 0.4126

= 1.7167

= 1.0647

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.7855
le= 259.21
R= 8.6603

= 29.931

λlimit= 60.606
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -20.01
M2 39.22
FOR M 2-2
M1 -6.41
M2 15.11
B H
COLUMN SIZE(@ FLOOR) 30 30
COLUMN SIZE(@ ABOVE) 30 30
COLUMN SIZE(@ BELOW) 40 40
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 900

DESIGN MOMENT FOR M 3-3


e01= -0.0268
e02= 0.0526 The equivalent moment
eeq= 0.021
ea= 0.02
ed= 0.0726
Msd 3-3 54.13
DESIGN MOMENT FOR M 2-2
e01= -0.0086
e02= 0.0203
eeq= 0.0087
ea= 0.02
ed= 0.0403
Msd 2-2 30.02

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.2
Use biaxial chart number 18, since
From biaxial chart No 18
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 720 mm2

A,smax 7200 mm2


Since
On each face
A 180
using diameter 14 bar on each face provide
2 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 204.55
COLUMN STIFFNESS @ ABOVE(KI) 204.55
COLUMN STIFFNESS @ BELOW(KI) 646.46

The equivalent moment

0.018
0.010
0.731

length to rebar center

r 18, since
each face provide

560
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
4th FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 40X40

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 1190.6 kn

T
AXIS I-I 47.41 TOP TPU
M 3-3
-38.65 BOTTOM
S OU

39.28 TOP
ETAB

M 2-2
AXIS 3-3 -25.75 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

3.3
= 1.3041

= 2.6082

= 1.9561

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.8549
le= 282.11
R= 133.33

= 2.1158

λlimit= 70.381
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 3.3

L 5 L 5

3.3
= 1.3041

= 2.6082

= 1.9561

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.8549
le= 282.11
R= 11.547

= 24.431

λlimit= 66.389
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -38.65
M2 47.41
FOR M 2-2
M1 -25.75
M2 39.28
B H
COLUMN SIZE(@ FLOOR) 40 40
COLUMN SIZE(@ ABOVE) 30 30
COLUMN SIZE(@ BELOW) 40 40
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 1600

DESIGN MOMENT FOR M 3-3


e01= -0.0325
e02= 0.0398 The equivalent moment
eeq= 0.0159
ea= 0.02
ed= 0.0598
Msd 3-3 71.222
DESIGN MOMENT FOR M 2-2
e01= -0.0216
e02= 0.033
eeq= 0.0132
ea= 0.02
ed= 0.053
Msd 2-2 63.092

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 1280 mm2

A,smax 12800 mm2


Since
On each face
A 320
using diameter 14 bar on each face provide
3 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 646.46
COLUMN STIFFNESS @ ABOVE(KI) 204.55
COLUMN STIFFNESS @ BELOW(KI) 646.46

The equivalent moment

0.010
0.009
0.657

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
3rd FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 40X40

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 1639.7 kn

T
AXIS I-I 52.89 TOP TPU
M 3-3
-56.48 BOTTOM
S OU

44.93 TOP
ETAB

M 2-2
AXIS 3-3 -45.45 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

3.3
= 1.3041

= 4.4879

= 2.896

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.8918
le= 294.29
R= 133.33

= 2.2071

λlimit= 73.411
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 3.3

L 5 L 5

3.3
= 1.3041

= 4.4879

= 2.896

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.8918
le= 294.29
R= 11.547

= 25.486

λlimit= 74.714
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -52.89
M2 56.48
FOR M 2-2
M1 -44.93
M2 45.45
B H
COLUMN SIZE(@ FLOOR) 40 40
COLUMN SIZE(@ ABOVE) 40 40
COLUMN SIZE(@ BELOW) 50 50
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 1600

DESIGN MOMENT FOR M 3-3


e01= -0.0323
e02= 0.0344 The equivalent moment
eeq= 0.0138
ea= 0.02
ed= 0.0544
Msd 3-3 89.275
DESIGN MOMENT FOR M 2-2
e01= -0.0274
e02= 0.0277
eeq= 0.0111
ea= 0.02
ed= 0.0477
Msd 2-2 78.245

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 1280 mm2

A,smax 12800 mm2


Since
On each face
A 320
using diameter 14 bar on each face provide
3 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 646.46
COLUMN STIFFNESS @ ABOVE(KI) 646.46
COLUMN STIFFNESS @ BELOW(KI) 1578.3

The equivalent moment

0.012
0.011
0.904

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
2nd FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 50X50

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 2090.3 kn

T
AXIS I-I 54.94 TOP TPU
M 3-3
-64.75 BOTTOM
S OU

48.24 TOP
ETAB

M 2-2
AXIS 3-3 -56.7 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

3.3
= 3.1838

= 6.3676

= 4.7757

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9283
le= 306.33
R= 208.33

= 1.4704

λlimit= 71.212
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 3.3

L 5 L 5

3.3
= 3.1838

= 6.3676

= 4.7757

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9283
le= 306.33
R= 14.434

= 21.223

λlimit= 71.27
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -54.94
M2 64.75
FOR M 2-2
M1 -48.24
M2 56.7
B H
COLUMN SIZE(@ FLOOR) 50 50
COLUMN SIZE(@ ABOVE) 40 40
COLUMN SIZE(@ BELOW) 50 50
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 2500

DESIGN MOMENT FOR M 3-3


e01= -0.0263
e02= 0.031 The equivalent moment
eeq= 0.0124
ea= 0.02
ed= 0.051
Msd 3-3 106.56
DESIGN MOMENT FOR M 2-2
e01= -0.0231
e02= 0.0271
eeq= 0.0109
ea= 0.02
ed= 0.0471
Msd 2-2 98.506

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 2000 mm2

A,smax 20000 mm2


Since
On each face
A 500
using diameter 16 bar on each face provide
3 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 190 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 1578.3
COLUMN STIFFNESS @ ABOVE(KI) 646.46
COLUMN STIFFNESS @ BELOW(KI) 1578.3

The equivalent moment

0.008
0.007
0.738

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
1st FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 50X50

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 2593.8 kn

T
AXIS I-I 55.06 TOP TPU
M 3-3
-87.36 BOTTOM
S OU

46.85 TOP
ETAB

M 2-2
AXIS 3-3 76.93 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* single curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

3.6
= 3.1838

= 6.1022

= 4.643

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9265
le= 305.75
R= 208.33

= 1.4676

λlimit= 65.757
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 3.3

L 5 L 5

3.6
= 3.1838

= 6.1022

= 4.643

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9265
le= 305.75
R= 14.434

= 21.183

λlimit= 65.225
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -55.06
M2 87.36
FOR M 2-2
M1 -46.85
M2 76.93
B H
COLUMN SIZE(@ FLOOR) 50 50
COLUMN SIZE(@ ABOVE) 50 50
COLUMN SIZE(@ BELOW) 50 50
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 2500

DESIGN MOMENT FOR M 3-3


e01= -0.0212
e02= 0.0337 The equivalent moment
eeq= 0.0135
ea= 0.02
ed= 0.0537
Msd 3-3 139.24
DESIGN MOMENT FOR M 2-2
e01= -0.0181
e02= 0.0297
eeq= 0.0119
ea= 0.02
ed= 0.0497
Msd 2-2 128.81

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 2000 mm2

A,smax 20000 mm2


Since
On each face
A 500
using diameter 14 bar on each face provide
4 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 1578.3
COLUMN STIFFNESS @ ABOVE(KI) 1578.3
COLUMN STIFFNESS @ BELOW(KI) 1446.8

The equivalent moment

0.010
0.009
0.915

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
Mezz FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 50X50

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 3009.5 kn

T
AXIS I-I 15.73 TOP TPU
M 3-3
-120.17 BOTTOM
S OU

15.92 TOP
ETAB

M 2-2
AXIS 3-3 -105.85 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 3.6

L 5.15 L 5.63

3.3
= 2.9185

= 9.5203

= 6.2194

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.943
le= 339.49
R= 208.33

= 1.6295

λlimit= 53.272
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 3.6

L 5 L 5

3.3
= 2.9185

= 9.5203

= 6.2194

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.943
le= 339.49
R= 14.434

= 23.52

λlimit= 53.76
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -15.73
M2 120.17
FOR M 2-2
M1 -15.92
M2 105.85
B H
COLUMN SIZE(@ FLOOR) 50 50
COLUMN SIZE(@ ABOVE) 50 50
COLUMN SIZE(@ BELOW) 60 60
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 2500

DESIGN MOMENT FOR M 3-3


e01= -0.0052
e02= 0.0399 The equivalent moment
eeq= 0.0219
ea= 0.02
ed= 0.0599
Msd 3-3 180.36
DESIGN MOMENT FOR M 2-2
e01= -0.0053
e02= 0.0352
eeq= 0.019
ea= 0.02
ed= 0.0552
Msd 2-2 166.04

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 2000 mm2

A,smax 20000 mm2


Since
On each face
A 500
using diameter 14 bar on each face provide
3 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


10.2
20.1
2450
2900
BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 1446.8
COLUMN STIFFNESS @ ABOVE(KI) 1578.3
COLUMN STIFFNESS @ BELOW(KI) 3272.7

The equivalent moment

0.013
0.012
1.062

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
GROUND FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 60X60

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 3415.4 kn

T
AXIS I-I -47.34 TOP TPU
M 3-3
53.5 BOTTOM
S OU

-51.3 TOP
ETAB

M 2-2
AXIS 3-3 11.98 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.6
L 5.15 L 5.63

L 3.3

L 5.15 L 5.63

2.85
= 6.6019

= 14.246

= 10.424

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9644
le= 318.24
R= 300

= 1.0608

λlimit= 72.121
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.6
L 5 L 5

L 3.3

L 5 L 5

2.85
= 6.6019

= 14.246

= 10.424

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9644
le= 318.24
R= 17.321

= 18.374

λlimit= 55.838
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -47.34
M2 53.5
FOR M 2-2
M1 -11.98
M2 51.3
B H
COLUMN SIZE(@ FLOOR) 60 60
COLUMN SIZE(@ ABOVE) 50 50
COLUMN SIZE(@ BELOW) 60 60
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 3600

DESIGN MOMENT FOR M 3-3


e01= -0.0139
e02= 0.0157 The equivalent moment
eeq= 0.0063
ea= 0.02
ed= 0.0357
Msd 3-3 121.81
DESIGN MOMENT FOR M 2-2
e01= -0.0035
e02= 0.015
eeq= 0.0076
ea= 0.02
ed= 0.035
Msd 2-2 119.61

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 2880 mm2

A,smax 28800 mm2


Since
On each face
A 720
using diameter 14 bar on each face provide
5 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 3272.7
COLUMN STIFFNESS @ ABOVE(KI) 1446.8
COLUMN STIFFNESS @ BELOW(KI) 3789.5

The equivalent moment

0.005
0.005
0.837

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
1st B FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 60X60

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 3912.5 kn

T
AXIS I-I -50.72 TOP TPU
M 3-3
6.28 BOTTOM
S OU

-8.06 TOP
ETAB

M 2-2
AXIS 3-3 -4.34 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

3.3
L 5.15 L 5.63

L 2.85

L 5.15 L 5.63

1.5
= 7.6443

= 22.168

= 14.906

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9745
le= 277.74
R= 300

= 0.9258

λlimit= 53.095
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

3.3
L 5 L 5

L 2.85

L 5 L 5

1.5
= 7.6443

= 22.168

= 14.906

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9745
le= 277.74
R= 17.321

= 16.035

λlimit= 63.462
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -6.28
M2 50.72
FOR M 2-2
M1 -4.34
M2 8.06
B H
COLUMN SIZE(@ FLOOR) 60 60
COLUMN SIZE(@ ABOVE) 60 60
COLUMN SIZE(@ BELOW) 60 60
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 3600

DESIGN MOMENT FOR M 3-3


e01= -0.0016
e02= 0.013 The equivalent moment
eeq= 0.0071
ea= 0.02
ed= 0.033
Msd 3-3 128.97
DESIGN MOMENT FOR M 2-2
e01= -0.0011
e02= 0.0021
eeq= 0.0008
ea= 0.02
ed= 0.0221
Msd 2-2 86.31

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0
provide minimum reinforcement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 2880 mm2

A,smax 28800 mm2


Since
On each face
A 720
using diameter 14 bar on each face provide
5 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 236.83
BEAM STIFFNESS TOP RIGHT(Kb) 258.9
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 3789.5
COLUMN STIFFNESS @ ABOVE(KI) 3272.7
COLUMN STIFFNESS @ BELOW(KI) 7200

The equivalent moment

0.005
0.004
0.959

length to rebar center

r 17, since
each face provide
COLUMN DESIGN ACCORDING TO EBCS-2-1995
ON AXIS 3,I
2nd B FLOOR COLUMN DESIGN

BEAM 40X25 BEAM 40X25


I. DETERMINATION OF SLENDERNESS

COLUMN 60X60

BEAM 40X25
BEAM 40X25

AXIAL LOAD DIAGRAM

Nsd 3959.5 kn

T
AXIS I-I 6.79 TOP TPU
M 3-3
-16.19 BOTTOM
S OU

-2.55 TOP
ETAB

M 2-2
AXIS 3-3 4.54 BOTTOM

* DOUBLE OR SINGLE CURVATURE


ABOUT AXIS 3-3
* Double curvature
ABOUT AXIS 2-2
* Double curvature

FRAME TYPE IS NON-SWAY


�_𝐿𝐼𝑀𝐼𝑇=50−25(𝑀_1/𝑀_2 )

�=𝐿_𝐸/�

�=√(𝐼/𝐴)

CHECK FOR AXIS 3-3


BEAM COLUMN FRAMING

2.85
L 5.15 L 5.63

L 1.5

L 5.15 L 5.63

0
= 20.605

= 7.6443

= 14.125

For non-sway frame


�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.9732
le= 145.98
R= 300

= 0.4866

λlimit= 60.485
check SHORT COLUMN

CHECK FOR AXIS I-I


BEAM COLUMN FRAMING

2.85
L 5 L 5

L 1.5

L 5 L 5

0
= 13.5

= 0

= 6.75

�_𝑒/�=(𝛼_𝑚+0.4)/
(𝛼_𝑚+0.8) >0.7

le/l= 0.947
le= 142.05
R= 17.321

= 8.2014

λlimit= 64.042
check SHORT COLUMN
MOMENT 3-3 MOMENT 2-2
T
TPU
S OU
ETAB

IDENTIFICATION OF M1 AND M2
FOR M3-3
M1 -6.79
M2 16.19
FOR M 2-2
M1 -2.55
M2 4.54
B H
COLUMN SIZE(@ FLOOR) 60 60
COLUMN SIZE(@ ABOVE) 60 60
BEAM SIZE ( TOP LEFT) 25 40
BEAM SIZE ( TOP RIGHT) 25 40
BEAM SIZE ( BOTTOM LEFT) 25 40
BEAM SIZE ( BOTTOM RIGHT) 25 40
AREA OF COLUMN @ FLOOR(A) 3600

DESIGN MOMENT FOR M 3-3


e01= -0.0017
e02= 0.0041 The equivalent moment
eeq= 0.0018
ea= 0.02
ed= 0.0241
Msd 3-3 95.38
DESIGN MOMENT FOR M 2-2
e01= -0.0006
e02= 0.0011
eeq= 0.0005
ea= 0.02
ed= 0.0211
Msd 2-2 83.73

Chart parameters

C 25 µ2-2
S 300 µ3-3
fcd 11.333 ν
fyd 260.87
h' 3.4 length to rebar center
h'/h 0.1
Use biaxial chart number 17, since
From biaxial chart No 17
ω 0.11
provide the designed reinforement
𝐴_(𝑠,𝑚𝑖𝑛)=0.008∗𝐵∗�
A,smin 2880 mm2

A,smax 28800 mm2


Since
On each face
A 720
using diameter 14 bar on each face provide
3 diameter 14 bars

confinement bar
�_𝑠≥{█(∅_�/4@6 𝑚𝑚)┤

Øs 6
�≤{█(12∅_�@𝑏@350)┤

Spacing S 160 with diameter 8


BEAM STIFFNESS TOP LEFT(Kb) 266.67
BEAM STIFFNESS TOP RIGHT(Kb) 266.67
BEAM STIFFNESS BOTTOM LEFT(Kb) 258.9
BEAM STIFFNESS BOTTOM RIGHT(Kb) 236.83
COLUMN STIFFNESS @ FLOOR(KI) 7200
COLUMN STIFFNESS @ ABOVE(KI) 3789.5

The equivalent moment

0.004
0.003
0.970

length to rebar center

r 17, since
each face provide
Level Pd Lx1 Lx2 Ly1 Ly2 At Axial load fcd
Roof 9.419 5.15 5.63 5 5 26.95 253.8 11.33
5th 15.02 5.15 5.63 5 5 26.95 658.6 11.33
4th 15.02 5.15 5.63 5 5 26.95 1063.4 11.33
3rd 15.02 5.15 5.63 5 5 26.95 1468.2 11.33
2nd 15.02 5.15 5.63 5 5 26.95 1873.0 11.33
1st 16.619 5.15 5.63 5 5 26.95 2320.9 11.33
M 13.419 5.15 5.63 5 5 26.95 2682.5 11.33
G 13.419 5.15 5.63 5 5 26.95 3044.2 11.33
1st B 13.419 5.15 5.63 5 5 26.95 3405.8 11.33
2nd B 13.419 5.15 5.63 5 5 26.95 3767.4 11.33
Acolumn B,H Take B,H
22404 150 300
58132 250 300
93859 350 400
129586 400 400
165313 450 500
204844 500 500
236763 500 500
268682 550 600
300601 550 600
332520 600 600