MATERIAL SAFETY DATA SHEET

GLUCOSE

I. IDENTIFICATION OF THE PREPARATION AND OF THE COMPANY

PRODUCT NAME: GLUCOSE


CONTENTS OF KIT

PRODUCT PRODUCT NO PACK SIZE R1 Reagent R2 REAGENT R3 Reagent


NAME

GLUCOSE 51406001 5 x 100 mL 100 mL(5) 4 mL

GLUCOSE 51406002 1 x 1000 mL 1000 mL 4 mL

GLUCOSE 51208001 4 x100 mL 100 mL(4) 100 mL(4) 4 mL

GLUCOSE 52004014 10 x 8 mL 8 mL(10)

GLUCOSE 52002014 6 x 40 mL 40 mL(6)

GLUCOSE 52005014 4 x 35 mL 35 mL

GLUCOSE 52004014 6 x 30 mL 30 mL(6)

GLUCOSE 52002014 8 x 34 mL 34 mL(8)

GLUCOSE 52005014 7 x 100 mL 100 mL

Product description : Clinical chemistry reagent, for medical diagnostic testing purposes.

Company identification : AGAPPE DIAGNOSTICS LTD.


PATTIMATTOM (P.0), DIST. ERNAKULAM
KERALA-683562

Phone &Fax : +91-484-2867000, +91-484-2689666

For: AGAPPE DIAGNOSTICS SWITZERLAND GmbH


Knonaurstrasse 54-6330, Cham
Switzerland
Phone: +41 41 78060 10
Phone No. for emergency : +91-484-3120002
Safety Data Sheet Information: qa@agappe.in
II. HAZARD IDENTIFICATION
GLUCOSE REAGENT
Classification: NONE
Negative health effects: NONE
Negative environmental effects: No specific information available
III. COMPOSITION/INGREDIENT INFORMATION
GLUCOSE R1 REAGENT

Chemical Name Concentration (%) CAS N.CE Classification


Tris buffer 1.11 5625-37-6 Aqueous solution

Glucose oxidase 0.001 Aqueous solution


MATERIAL SAFETY DATA SHEET
GLUCOSE

Amino phenazone <0.1 108-95-2 203-632-7 Aqueous solution

Phenol 0.0028 108-95-2 Aqueous solution

GLUCOSE R2 REAGENT

Chemical Name Concentration (%) CAS N.CE Classification

Glucose 0.1 4264-83-9 224-246-5 Aqueous solution

GLUCOSE STANDARD

Chemical Name Concentration (%) CAS N.CE Classification

Glucose <1 60-27-5 205-605-5 Aqueous solution

HAZARDOUS SYMBOL: NONE


Toxicological information

Tris buffer: Not listed in the current edition of DGR


Glucose oxidase: Not listed in the current edition of DGR
Amino phenazone: Not listed in the current edition of DGR
Phenol: Though listed in current edition of DGR, an oral LD50 value of 9842857mg/Kg, for 0.0028% of Phenol
aqueous solution is above the upper limit of classification criteria of 300mg/kg and hence is not hazardous.
Glucose: Not listed in the latest edition of DGR

IV. FIRST AID MEASURES

Inhalation: Use the product in sufficiently ventilated working places. If inhaled, remove from exposure and move to
fresh air immediately. Seek medical help.
Skin contact: Flush skin with plenty of water for at least 10 minutes. Take off the contaminated clothing. Seek
medical aid.
Eyes: Flush eyes with plenty of water for at least 10 minutes occasionally lifting the upper and lower eye lids.
Ingestion: If the victim is conscious and alert, give 2-3 cupfuls of water or milk. Never give anything by mouth to an
unconscious person. Get medical help immediately.
V. FIRE FIGHTING MEASURES

General information: As in any fire, wear a self contained breathing apparatus in pressure-demand. MISHA/NIOSH
approved or equivalent and full protective gear. Combustion generates toxic fumes.
Extinguishing media: Use water spray, dry powder and carbon dioxide.

VI. ACCIDENTAL RELEASE MEASURES

General Information: Use proper personal protective equipment.

Spills and leaks: In case of spilling, embank the spill with inert material (sand, sawdust etc.) Vacuum or sweep up
material and place in a suitable container for disposal. Wash the soiled space with plenty of water.
Environmental precautions: Avoid waste and surface water contamination. In case of surface or sewerage water
contamination report to the local authorities.
MATERIAL SAFETY DATA SHEET
GLUCOSE

VII. HANDLING AND STORAGE

Handling: Act according to good safety and sanitary regulations. Avoid direct contact with eyes, skin and clothing.
Avoid inhalation of fumes. Wash accurately after handling. Do not drink or eat during work.

Storage: no special requirements. Keep away from heat, flames and sparks. Store in closed containers in ventilated,
dark room at controlled temperature (2-8°C).

VIII. EXPOSURE CONTROL/PERSONAL PROTECTION

Act according to usual safety measures regarding handling of chemistry substances. During work do not eat, drink or
smoke. Before starting and at the end of work wash your hands.
Control the exposure.
Respiratory protection: protection media (masks with suitable filters against organic fumes) are necessary only in
case of fire or high temperature.
Skin protection: use suitable laboratory gloves and clothing.
Eye protection: use protective glasses.

IX. PHYSICAL & CHEMICAL PROPERTIES

Aspect - Glucose R1 reagent: Liquid Glucose R2 reagent: Liquid/Enzyme


Colour - Glucose R1 reagent: Colorless Glucose R2 reagent: Colorless
Odour - Glucose R1 reagent: Odourless Glucose R2 reagent: Odourless
pH - Glucose R1 reagent: 6.9 Glucose R2 reagent: 7.0

Aspect - Glucose Standard: Liquid


Colour - Glucose Standard: Colorless
Odour - Glucose Standard:Odourless
pH - Glucose Standard : 6.9

Flash point Irrelevant


Water solubility Soluble

X. STABILITY & REACTIVITY

STABILITY: When used for testing, product is stable at ambient conditions. High temperature affects the diagnostic
potency of the reagent
Conditions to avoid: high temperature, light etc.
Incompatibility with other reagents: NA.
Hazardous decomposition products: No known hazardous decomposition products.
Hazardous polymerization: Will not occur
XI. TOXICOLOGICAL INFORMTION

Inhalation: If inhaled, may cause respiratory tract irritation.


Skin contact: Contact with skin may cause irritation.
Eye contact: May cause eye irritation
Ingestion: If ingested, may cause gastrointestinal irritation with nausea, vomiting, diarrhea. Danger of cumulative
effects
MATERIAL SAFETY DATA SHEET
GLUCOSE

XII. ECOLOGICAL INFORMATION

Act as per good laboratory practices, avoiding dispersing the product and packaging in the environment. No ecological
product information available.

XIII. DISPOSAL CONSIDERATIONS


The waste disposal must be performed observing the local and national laws in force. Do not empty into drains,
surface and underground waters.

XIV. TRANSPORT INFORMATION


ICAO: Not regulated as a hazardous material
IATA: Not regulated as a hazardous material.
IMO: Not regulated as a hazardous material.
RID/ADR: Not regulated as a hazardous material

XV. REGULATORY INFORMATION


Reagents

R PHRASES

S PHRASES 24 Avoid contact with eyes.


25 In case of contact with eyes, rinse immediately with
plenty of water and seek medical advice.
Take off immediately all contaminated clothing.
27 After contact with skin, wash immediately with plenty of
water.
28 Wear suitable protective clothing, gloves and eye/face
protection.
36/37/39 In case of accident or if you feel unwell, seek medical
advice immediately
45

Standard

R PHRASES
S PHRASES 24/25 In case of contact with eyes, rinse immediately with
plenty of water and seek medical advice.

European/International Regulations
European Labeling in Accordance with EC Directives
Hazard Symbols: NONE
Risk Phrases:.
Safety Phrases:
S 24/25 Avoid contact with skin and eyes.

XVI ADDITIONAL INFORMATION

The information above is believed to be accurate and represents the best


information currently available to us. The product is suitable for air cargo since it is not a dangerous product as per any