Professional Documents
Culture Documents
132/11Kv Al Sadd 3 Substation: Updated Structural Stair Design
132/11Kv Al Sadd 3 Substation: Updated Structural Stair Design
132/11Kv Al Sadd 3 Substation: Updated Structural Stair Design
3970
Stair geometry
Number of steps; Nsteps = 9
Waist depth for stair flight; hspan = 250 mm
Going of each step; Going = 280 mm
Rise of each step; Rise = 175 mm
Angle of stairs; Rake = atan(Rise / Going) = 32.01 deg
Upper landing geometry
Support condition; Simply supported
Landing length; Lupper = 1350 mm
Depth of landing; hupper = 250 mm
Lower landing geometry
Support condition; Continuous first interior support
Landing length; Llower = 380 mm
Depth of landing; hlower = 250 mm
Material details
Characteristic strength of concrete; fcu = 35 N/mm2
Characteristic strength of reinforcement; fy = 500 N/mm2
Nominal cover to reinforcement; cnom = 50 mm
Density of concrete; conc = 25.0 kN/m3
Loading details
Characteristic imposed loading; qk = 5.000 kN/m2
Characteristic loading from finishes; gk_fin = 1.250 kN/m2
Average stair self weight; gk_swt = (hspan / Cos(Rake) + Rise / 2) conc = 9.558 kN/m2
Project Job no.
AL SADD 3 SUBSTATION - GTC/735C/2015
Calcs for Start page no./Revision
Stair-3 Design (lvl.+0.45 to lvl. +2.025) STR- 2
Calcs by Calcs date Checked by Checked date Approved by Approved date
MS 5/2/2019 AS 5/2/2019 ACS 5/2/2019