Revision A:
• 10.TROUBLESHOOTING has been corrected.
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Please void OB466.

INDOOR UNIT
No. OBH466
DATA BOOK REVISED EDITION-A

Wireless type
Models

MSZ-HC25VA - E1

MSZ-HC35VA - E1

MSZ-HC35VAB - E1

Outdoor unit data book


MUZ-HC·VA Series (OBH467)

CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················2
3. SPECIFICATION·················································3
4. NOISE CRITERIA CURVES ·······························4
5. OUTLINES AND DIMENSIONS ·························5
6. WIRING DIAGRAM ············································5
7. REFRIGERANT SYSTEM DIAGRAM ················6
8. SERVICE FUNCTIONS ······································7
9.
10.
11.

PARTS CATALOG (OBB466)

NOTE:
RoHS compliant products have <G> mark on the spec name plate.
OBH466A.qxp 07.2.19 1:56 PM Page 2

Revision A:
• 10.TROUBLESHOOTING has been corrected.
• Color of lead wire (indoor fan motor : sensor part) of 10-5.”Trouble criterion of main parts” has been corrected.
• 10-6.”ACheck of indoor fan motor” has been corrected. [MSZ-HC25]

1 TECHNICAL CHANGES

MSZ-HA25VA - E1 ➔ MSZ-HC25VA - E1
MSZ-HA35VA - E1 ➔ MSZ-HC35VA - E1
MSZ-HA35VA - E1 ➔ MSZ-HC35VAB - E1
1. Indoor fan motor has been changed. (DC ➔ AC) [MSZ-HC25]
2. Indoor heat exchanger has been changed. [MSZ-HC35]
3. Indoor electronic control P.C. board has been changed.

2 PART NAMES AND FUNCTIONS

MSZ-HC25VA
MSZ-HC35VA
MSZ-HC35VAB
Air inlet

Air filter (Anti-mold) Front panel

Air outlet

Vertical vane Remote controller

Horizontal vane

Remote control
receiving section

Emergency operation switch (E.O. SW) Operation Indicator


lamp

ACCESSORIES

1 Installation plate 1
2 Installation plate fixing screw 4 o 25 mm 5
3 Battery (AAA) for remote controller 2
4 Wireless remote controller 1
5 Felt tape (Used for left or left-rear piping) 1

2
OBH466A.qxp 07.2.19 1:56 PM Page 3

3 SPECIFICATION

Indoor model MSZ-HC25VA MSZ-HC35VA MSZ-HC35VAB

Function Cooling Heating Cooling Heating Cooling Heating


Single phase
Power supply
230V,50Hz
Air flow(Super High) K /h 630 546 612 552 612 552
Capacity
Air flow(High/Med./Low) K /h 522/420/318 468/390/306 504/408/312 480/402/294 504/408/312 480/402/294
Running current ✽1
Electrical

A 0.22
Power input ✽1 W 40 23
data

Fan motor current ✽1 A 0.22


Fan motor Model RC4V18-BA or CA RC0J40-ED
Dimensions WOHOD mm 788O295O225
Weight kg 9
Air direction 4
Sound level (Super High) dB(A) 43
remarks
Special

Sound level (High/Med./Low) dB(A) 38/32/26


Fan speed (Super High) rpm 1,110 980 1,140 1,050 1,140 1,050
Fan speed (High/Med./Low) rpm 950/800/650 870/750/630 980/830/680 940/820/660 980/830/680 940/820/660
Fan speed regulator 4
Remote controller model MP06B
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor Dry-bulb temperature 27:Wet-bulb temperature 19:
Outdoor Dry-bulb temperature 35:
Heating : Indoor Dry-bulb temperature 20:
Outdoor Dry-bulb temperature 7:Wet-bulb temperature 6:
Refrigerant piping length (one way): 5m
✽1 Measured under rated operating frequency.

Specifications and rating conditions of main electric parts


Fuse (F11) T3.15AL 250V
Horizontal vane motor (MV) 12V DC
Varistor (NR11) S10K320E3K1(ERZV14D471)
Terminal block (TB) 3P

3
OBH466A.qxp 07.2.19 1:56 PM Page 4

4 NOISE CRITERIA CURVES

MSZ-HC25VA MSZ-HC35VA
MSZ-HC35VAB

FAN SPEED FUNCTION SPL(dB(A)) LINE FAN SPEED FUNCTION SPL(dB(A)) LINE

COOLING 43 COOLING 43
Super High Super High
HEATING 43 HEATING 43

90 90

OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR


OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR

80 80

70 70
NC-70 NC-70

60 60
NC-60 NC-60

50 50
NC-50 NC-50

40 40
NC-40 NC-40

30 30
NC-30 NC-30

APPROXIMATE APPROXIMATE
20 20
THRESHOLD OF THRESHOLD OF
HEARING FOR NC-20 HEARING FOR NC-20
CONTINUOUS CONTINUOUS
NOISE NOISE
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz

Test conditions
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
Heating : Dry-bulb temperature 20:

INDOOR UNIT
WALL
1m

0.8m

MICROPHONE

4
OBH466A.qxp 07.2.19 1:57 PM Page 5

5 OUTLINES AND DIMENSIONS

MSZ-HC25VA Unit : mm
MSZ-HC35VA
MSZ-HC35VAB

11 X 26 Oblong hole 11 X 20 Oblong hole


59 225 225 59

18.5
Installation plate
788

253.5
254.5

235
214
215
155 155

2
40.5

41.5
59 335 320 74
Indoor unit
5 225
Air in Wall hole [65
Installation plate
Piping
295
58

8
42 42 Drain hose

100

57
119
137
53 607 128 Air out

57 18

Insulation [35 O.D


42
140

42

Piping

Liquid line [6.35 - 0.5 m (Flared connection [6.35)


Gas line [9.52 - 0.43 m (Flared connection [9.52)
58 50 Drain hose Insulation[28 O.D Connected part [16 O.D

6 WIRING DIAGRAM

MSZ-HC25VA

5
OBH466A.qxp 07.2.19 1:57 PM Page 6

MSZ-HC35VA
MSZ-HC35VAB

7 REFRIGERANT SYSTEM DIAGRAM

MSZ-HC25VA
MSZ-HC35VA
MSZ-HC35VAB
Unit : mm

Refrigerant pipe [9.52


(with heat insulator)

Indoor coil
Indoor thermistor
heat RT12
exchanger Flared connection

Room temperature
thermistor
RT11

Flared connection

Refrigerant pipe [6.35


(with heat insulator)

Refrigerant flow in cooling


Refrigerant flow in heating

6
OBH466A.qxp 07.2.19 1:57 PM Page 7

8 SERVICE FUNCTIONS

MSZ-HC25VA
MSZ-HC35VA
MSZ-HC35VAB
8-1. TIMER SHORT MODE
For service, set time can be shortened by short circuit of JPG and JPS on the electronic control P.C. board.
The time will be shortened as follows. (Refer to 10-7.)
Set time : 1-minute ➔ 1-second
Set time : 3-minute ➔ 3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is
shortened by short circuit of JPG and JPS.)
8-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below :

J1 J2

NOTE : For modification, take out


the batteries and press the
OPERATE/STOP(ON/OFF)
button twice or 3 times at
first.
After finish modification,
put back the batteries then
press the RESET button.

The P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.

Table 1
1 unit operation 2 units operation 3 units operation 4 units operation
No. 1 unit No modification Same as at left Same as at left Same as at left
No. 2 unit – Solder J1 Same as at left Same as at left
No. 3 unit – – Solder J2 Same as at left
No. 4 unit – – – Solder both J1 and J2

How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are
set.
The setting will be cancelled if the breaker has turned OFF, or the power supply has shut down.
Please conduct the above setting once again after the power has restored.

7
OBH466A.qxp 07.2.19 1:57 PM Page 8

8-3. AUTO RESTART FUNCTION


When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. “AUTO RESTART FUNCTION” automatically starts operation
in the same mode just before the shutoff of the main power.
Operation
1 If the main power has been cut, the operation settings remain.
2 After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to release “AUTO RESTART FUNCTION”
1Turn off the main power for the unit.
2Solder the Jumper wire to JR07 on the indoor electronic control P.C. board. (Refer to 10-7.)

Indoor electronic

CN112 CN111
control P.C. board

CN151
CN10A
JR07

NOTE:
• The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the
remote controller.
• If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
• If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is off.
• To prevent breaker OFF due to the rush of starting current, systematize other home appliance not to turn ON at the
same time.
• When some air conditioners are connected to the same supply system, if they are operated before power failure,
the starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.